Kovalenko RA, Rudenko VV, Kashin VA, Cherebillo VY, Ptashnikov DA. [Assessment of the safety and accuracy of implantation of screws into the C2 vertebra using individual 3D-navigation matrices].
ZHURNAL VOPROSY NEĬROKHIRURGII IMENI N. N. BURDENKO 2020;
84:42-50. [PMID:
32412193 DOI:
10.17116/neiro20208402142]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Introduction
Individual 3D-navigation matrices are valuable to increase the safety of screw implantation into the axis.
Objective
To analyze safety and accuracy of screw deployment into the axis using individual 3D-navigation matrices compared to free hand technique.
Material and methods
A retrospective analysis included 23 patients (group 1) who underwent implantation of 44 screws into the axis using the «free hand» technique. The screws were installed along the transpedicular or pars trajectory. A prospective analysis enrolled 17 patients (group 2) who underwent installation of 34 screws using individual navigation matrices. 3D-printing technology was applied for manufacturing these matrices. Implantation results were evaluated considering postoperative CT data and SGT (Screw Guide Template) system.
Results
In the 1st group («free hand»), grade 0 and 1 (no malposition or less than 50% of screw diameter) were recorded for 29 (65.91%) screws, grade 2 - for 13 (29.55%) screws, grade 3 - for 2 (4.45%) screws. Intraoperative injury of the vertebral artery without postoperative neurological deficit occurred in 4 (8.89%) patients. In the 2nd group, 97% of screws were implanted in accordance with grades 1 and 2. Deviation grade 2 was registered in 11 cases (32.35%). Mean deviation was 1.8 ± 1.0 mm. In the 2nd group, 28 (82.35%) out of 34 screws were completely within the bone structures (grade 0), 4 (11.76%) screws perforated pedicles for less than 50% of their diameter (grade 1). There were 2 cases of malposition grade 2 and 3 without vertebral artery injury.
Conclusion
Individual 3D navigation matrix is an effective method for screw installation into the axis. This approach exceeds fluoroscopy-assisted "free hand" technique in terms of safety of implantation.
Collapse