1
|
Aditianingsih D, Heriwardito A, Agusta LS, Leonard EN, Annabelle C. Internal jugular distensibility index as a predictor of fluid responsiveness in adult patients undergoing elective surgery - A prospective accuracy study. Indian J Anaesth 2025; 69:206-213. [PMID: 40160910 PMCID: PMC11949394 DOI: 10.4103/ija.ija_457_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 11/03/2024] [Accepted: 11/06/2024] [Indexed: 04/02/2025] Open
Abstract
Background and Aims Assessing the intravascular volume is necessary in patients undergoing surgery, but predicting how the body will respond to fluid can be challenging. Evaluation of the internal jugular vein distensibility index (IJV-DI) is an alternative method to determine intravascular volume status. This study aims to determine the suitability of measuring stroke volume by using IJV-DI measurement compared with transthoracic echocardiography in assessing the fluid responsiveness in elective surgery patients. Methods This prospective study involved 79 subjects undergoing elective surgery under general anaesthesia. Following anaesthesia induction, IJV-DI and stroke volume measurements were performed before and after fluid administration. Subjects experiencing an increase in stroke volume of more than 10% were categorised as responders. The primary outcome was the suitability of IJV-DI in determining fluid responsiveness compared to transthoracic echocardiography in elective surgery patients. The data were then analysed to assess its diagnostic value using the receiver operator characteristic (ROC) curve, the appropriate cut-off point using the Youden index, and the correlation using Spearman's correlation test. Results A total of 45 subjects were responders. Our analysis revealed an area under the curve (AUC) value of 0.871 (95% CI: 0.790, 0.951). The optimal cut-off value was found at an internal jugular vein distensibility index of >12.62% with a sensitivity of 84.4% and a specificity of 79.4%. A moderate positive correlation existed between the index and stroke volume increase (r = 0.535, P < 0.001). Conclusion IJV-DI assessment is compatible with transthoracic echocardiography stroke volume measurement for evaluating elective surgery patients' fluid response.
Collapse
Affiliation(s)
- Dita Aditianingsih
- Department of Anesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Indonesia
| | - Aldy Heriwardito
- Department of Anesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Indonesia
| | - Laksmi Senja Agusta
- Department of Anesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Indonesia
| | - El Nissi Leonard
- Department of Anesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Indonesia
| | - Chrisella Annabelle
- Department of Anesthesiology and Intensive Care, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Indonesia
| |
Collapse
|
2
|
N P, Sinha M, Kumar M, Ramchandani S, Khetrapal M, Karoo K, Mesa BK. Role of Internal Jugular Vein Collapsibility Index in Predicting Post-spinal Hypotension in Pregnant Women Undergoing Cesarean Section: A Prospective Observational Study. Cureus 2023; 15:e39389. [PMID: 37362461 PMCID: PMC10286763 DOI: 10.7759/cureus.39389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/19/2023] [Indexed: 06/28/2023] Open
Abstract
Introduction Post-spinal hypotension (PSH) frequently occurs in women undergoing cesarean section. In recent studies, Ultrasound-guided measurements of the internal jugular vein (IJV) have been reported to predict fluid responsiveness. We planned to evaluate the correlation between the internal jugular vein collapsibility index (IJVCI) and PSH in cesarean section patients. Methods Ninety-one parturients who underwent elective lower segment cesarean section with a singleton pregnancy were recruited. Preoperatively, patients were placed in a supine position with a 15-degree left lateral tilt. Maximum (at the end of expiration) and minimum (at the end of inspiration) IJV diameters (mm) and IJVCI were assessed using M-mode imaging during spontaneous and deep breathing. Spinal anaesthesia was performed at the L3-4 or L4-5 level. Systolic blood pressure, diastolic blood pressure, mean arterial pressure, heart rate, respiratory rate, and SpO2 were recorded from baseline till the delivery of the baby. Results Among 91 patients, 40 (45.5%) patients had at least one episode of hypotension. Demographic variables and baseline vitals were comparable between the hypotensive and normotensive groups (p>0.05). In spontaneous and deep breathing, IJV diameter at the end-expiration (IJVdmax), end-inspiration (IJVdmin), and IJVCI amongst both hypotensive and non-hypotensive pregnant women were statistically similar. Receiver Operating Characteristic (ROC) curve analysis showed that during spontaneous breathing, using a cut-off point of 29.5%, IJVCI had a sensitivity and specificity of 70% and 23%, respectively, for predicting PSH; whereas during deep breathing, IJVCI had a sensitivity and specificity of 77% and 27%, respectively, for predicting the same using a cut-off value of 37.5%. Conclusion We conclude that internal jugular vein parameters such as maximum diameter, minimum diameter, and IJVCI during spontaneous and deep breathing cannot be used as reliable predictors of post-spinal hypotension in pregnant patients undergoing elective cesarean section.
Collapse
Affiliation(s)
- Pharanitharan N
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Mamta Sinha
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Mayank Kumar
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Sarita Ramchandani
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Monica Khetrapal
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Khushbu Karoo
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| | - Bharath K Mesa
- Anaesthesiology, All India Institute of Medical Sciences, Raipur, Raipur, IND
| |
Collapse
|
3
|
Wang MK, Piticaru J, Kappel C, Mikhaeil M, Mbuagbaw L, Rochwerg B. Internal jugular vein ultrasound for the diagnosis of hypovolemia and hypervolemia in acutely ill adults: a systematic review and meta-analysis. Intern Emerg Med 2022; 17:1521-1532. [PMID: 35718838 DOI: 10.1007/s11739-022-03003-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Accepted: 05/10/2022] [Indexed: 11/05/2022]
Abstract
Accurate volume status assessments allow physicians to rapidly implement therapeutic measures in acutely unwell patients. However, existing bedside diagnostic tools are often unreliable for assessing intravascular volume. We searched PUBMED, EMBASE, CENTRAL, and Web of Science for English language articles without date restrictions on January 20, 2022. Studies reporting the diagnostic accuracy of IJV-US for hypovolemia and/or hypervolemia in an acute care setting were screened for inclusion. We included studies using any method of IJV-US assessment as the index test, compared against any reference standard. We fitted hierarchical summary receiver operating characteristic (HSROC) models for meta-analysis of diagnostic test accuracy, separately for hypovolemia and hypervolemia. Two reviewers independently extracted data and assessed risk of bias using QUADAS-2. We assessed certainty of evidence using the GRADE approach. A total of 26 studies were included, of which 19 studies (956 patients) examined IJV-US for hypovolemia and 13 studies (672 patients) examined IJV-US for hypervolemia. For the diagnosis of hypovolemia, IJV-US had a pooled sensitivity of 0.82 (95% CI 0.76 to 0.87; moderate-certainty evidence) and specificity of 0.82 (95% CI 0.73 to 0.88; moderate-certainty evidence). Measurement of IJV collapsibility indices had higher diagnostic accuracy (sensitivity 0.85, 95% CI 0.80 to 0.89; specificity 0.78, 95% CI 0.64 to 0.88) than static IJV indices (sensitivity 0.73, 95% CI 0.60 to 0.82; specificity 0.70, 95% CI 0.48 to 0.86). For the diagnosis of hypervolemia, IJV-US had a pooled sensitivity of 0.84 (95% CI 0.70 to 0.92; moderate-certainty evidence) and specificity of 0.70 (95% CI 0.55 to 0.82; very low-certainty evidence). IJV-US has moderate sensitivity and specificity for the diagnosis of hypervolemia and hypovolemia. Randomized controlled trials are needed to determine the role of IJV-US for guiding therapeutic interventions aimed at optimizing volume status.
Collapse
Affiliation(s)
- Michael Ke Wang
- Department of Medicine, McMaster University, Hamilton, Canada.
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada.
- Population Health Research Institute, McMaster University, 237 Barton Street East, Hamilton, ON, Canada.
| | - Joshua Piticaru
- Department of Medicine, St. Joseph's Hospital, Syracuse, NY, USA
| | - Coralea Kappel
- Department of Medicine, McMaster University, Hamilton, Canada
| | | | - Lawrence Mbuagbaw
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada
- Department of Anesthesia, McMaster University, Hamilton, Canada
- Biostatistics Unit, Father Sean O'Sullivan Research Centre, St Joseph's Healthcare, Hamilton, Canada
- Centre for Development of Best Practices in Health (CDBPH), Yaoundé Central Hospital, Yaoundé, Cameroon
- Department of Global Health, Stellenbosch University, Cape Town, South Africa
| | - Bram Rochwerg
- Department of Medicine, McMaster University, Hamilton, Canada
- Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Canada
| |
Collapse
|
4
|
Elbadry AA, El dabe A, Abu Sabaa MA. Pre-operative Ultrasonographic Evaluation of the Internal Jugular Vein Collapsibility Index and Inferior Vena Cava Collapsibility Index to Predict Post Spinal Hypotension in Pregnant Women Undergoing Caesarean Section. Anesth Pain Med 2022; 12:e121648. [PMID: 35433379 PMCID: PMC8995868 DOI: 10.5812/aapm.121648] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 02/06/2022] [Accepted: 02/08/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Post spinal anesthesia hypotension (PSAH) is frequently encountered in anesthetic practice, especially during cesarean section. Ultrasound is a safe and easy technique for hemodynamic monitoring. Objectives: This study was conducted to assess the efficacy of pre-operative inferior vena cava collapsibility index (IVCCI) and internal jugular vein collapsibility index (IJVCI) in predicting PSAH. Methods: This cross-sectional blinded study included 55 pregnant females prepared for elective cesarean section. They were divided into two groups based on the incidence of PSAH: (1) cases with PSAH (26 cases); and (2) cases without PSAH (29 cases). All the cases underwent ultrasound-guided measurement of IVCCI and IJVCI. The efficacy of these parameters was assessed in predicting PSAH. Results: Cases in both groups expressed non-significant differences regarding demographic data. However, IVCCI had mean values of 38.27 and 23.97%, while IJVCCI had mean values of 46.50 and 33.41%, respectively, in cases with and without PSAH. For IVCCI, using a cut-off point of 33% had sensitivity and specificity (84.6 and 93.1%, respectively) for predicting PSAH, with a diagnostic accuracy of 89.1%. IJVCI had sensitivity and specificity of 84.6 and 82.8%, respectively, for predicting the same complication using a cut-off value of 38.5%. Conclusion: IVCCI and IJVCI are efficacious and reliable tools in predicting PSAH in pregnant ladies undergoing cesarean section, with a slight superiority for IVCCI regarding specificity and accuracy.
Collapse
Affiliation(s)
- Amr Arafa Elbadry
- Surgical Intensive Care and Pain Medicine, Faculty of Medicine, Tanta University, Tanta, Egypt
- Corresponding Author: Surgical Intensive Care and Pain Medicine, Faculty of Medicine, Tanta University, Tanta, Egypt.
| | - Ahmed El dabe
- Surgical Intensive Care and Pain Medicine, Faculty of Medicine, Tanta University, Tanta, Egypt
| | - Motaz Amr Abu Sabaa
- Surgical Intensive Care and Pain Medicine, Faculty of Medicine, Tanta University, Tanta, Egypt
| |
Collapse
|
5
|
Horejsek J, Kunstyr J, Michalek P, Porizka M. Novel Methods for Predicting Fluid Responsiveness in Critically Ill Patients—A Narrative Review. Diagnostics (Basel) 2022; 12:diagnostics12020513. [PMID: 35204603 PMCID: PMC8871108 DOI: 10.3390/diagnostics12020513] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/04/2022] [Accepted: 02/14/2022] [Indexed: 11/16/2022] Open
Abstract
In patients with acute circulatory failure, fluid administration represents a first-line therapeutic intervention for improving cardiac output. However, only approximately 50% of patients respond to fluid infusion with a significant increase in cardiac output, defined as fluid responsiveness. Additionally, excessive volume expansion and associated hyperhydration have been shown to increase morbidity and mortality in critically ill patients. Thus, except for cases of obvious hypovolaemia, fluid responsiveness should be routinely tested prior to fluid administration. Static markers of cardiac preload, such as central venous pressure or pulmonary artery wedge pressure, have been shown to be poor predictors of fluid responsiveness despite their widespread use to guide fluid therapy. Dynamic tests including parameters of aortic blood flow or respiratory variability of inferior vena cava diameter provide much higher diagnostic accuracy. Nevertheless, they are also burdened with several significant limitations, reducing the reliability, or even precluding their use in many clinical scenarios. This non-systematic narrative review aims to provide an update on the novel, less employed dynamic tests of fluid responsiveness evaluation in critically ill patients.
Collapse
Affiliation(s)
- Jan Horejsek
- Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12808 Prague, Czech Republic; (J.H.); (J.K.); (P.M.)
| | - Jan Kunstyr
- Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12808 Prague, Czech Republic; (J.H.); (J.K.); (P.M.)
| | - Pavel Michalek
- Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12808 Prague, Czech Republic; (J.H.); (J.K.); (P.M.)
- Department of Anaesthesia, Antrim Area Hospital, Antrim BT41 2RL, UK
| | - Michal Porizka
- Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, 12808 Prague, Czech Republic; (J.H.); (J.K.); (P.M.)
- Correspondence: ; Tel.: +420-702-089-475
| |
Collapse
|