1
|
Zaharieva Z, Tanev D, Danalev D. Development and validation of HPLC/DAD method for simultaneously determination of six prohibited substances in model matrices. ACTA CHROMATOGR 2020. [DOI: 10.1556/1326.2019.00749] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The authorities have identified an emerging trend where over-the-counter products, represented as dietary supplements, contain hidden active ingredients that could be harmful. Consumers may unknowingly take products laced with varying quantities of approved prescription drug ingredients, controlled substances, and untested and unstudied pharmaceutically active ingredients. Hidden ingredients are increasingly becoming a problem in products promoted for sexual enhancement, weight loss, or bodybuilding. The tests have revealed the presence of some undesired substances like sildenafil, tadalafil, vardenafil, and their analogues in tainted sexual enhancement products. The content of these substances is usually around the daily curative dose. A simple high-performance liquid chromatography (HPLC) method for simultaneously determination of sildenafil, vardenafil, tadalafil, dapoxetine, yohimbine, and sibutramine was developed and validated. InfinityLab Poroshell 120 EC-C18 (150 '4.6 mm '4 μm particles) was used, as well as a diode-array detector (DAD) at 230 nm, and a gradient flow with 0.030 М ammonium acetate buffer and acetonitrile. The method is linear in the following range: 2.5–37.5 μg/mL for yohimbine, 2.06–30.9 μg/mL for vardenafil, 2.0–30.0 μg/mL for sildenafil, 3.1–46.5 μg/mL for tadalafil, 1.98–29.7 μg/mL for dapoxetine, and 2.2–66.0 μg/mL for sibutramine. The linearity coefficient is R2 = 1 for all substances. Model matrices were spiked, and the analytical recoveries for all substances are in the range 97.5%–99.5%. The method exhibited an upper hand compared with previously reported methods in terms of speed and simplicity. Additionally, the mobile phase (also used as extracting, column washing, and diluting solvent) was composed of only buffer and acetonitrile, which rendered the method much cheaper than others.
Collapse
Affiliation(s)
- Zdravka Zaharieva
- 1 University of Chemical Technology and Metallurgy, Biotechnology Department, 8 blvd. Kliment Ohridski, Sofia, Bulgaria
- 2 Testing center Global Test Ltd, 31 Krushovski vrah Street, Sofia, Bulgaria
| | - Dimitar Tanev
- 2 Testing center Global Test Ltd, 31 Krushovski vrah Street, Sofia, Bulgaria
| | - Dancho Danalev
- 1 University of Chemical Technology and Metallurgy, Biotechnology Department, 8 blvd. Kliment Ohridski, Sofia, Bulgaria
| |
Collapse
|