1
|
Kubíková T, Bartoš M, Juhas Š, Suchý T, Sauerová P, Hubálek-Kalbáčová M, Tonar Z. Comparison of ground sections, paraffin sections and micro-CT imaging of bone from the epiphysis of the porcine femur for morphometric evaluation. Ann Anat 2018; 220:85-96. [PMID: 30092281 DOI: 10.1016/j.aanat.2018.07.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 06/27/2018] [Accepted: 07/11/2018] [Indexed: 11/15/2022]
Abstract
The aim of this study was to compare data on the volume fraction of bone and the thickness of the cortical compact bone acquired during microcomputed tomography (micro-CT) analysis with data acquired from identical samples using stereological analysis of either decalcified paraffin sections or ground sections. Additionally, we aimed to compare adjacent tissue samples taken from the major trochanter of the porcine femur to map the basic biological variability of trabecular bone. Fifteen pairs of adjacent tissue blocks were removed from the major trochanter of the proximal epiphyses of porcine femurs (female pigs aged 24-39 months, weight=59.16±8.15kg). In each sample, the volume of the cortical compact bone, the volume of the trabecular bone, and the thickness of the cortical compact bone was assessed using micro-CT. Afterwards, half of the samples were decalcified and processed using paraffin histological sections. Another half was processed into ground sections. The volume and thickness of bone was assessed in histological sections using stereological techniques. There were no significant differences in the bone volumes and thicknesses measured by micro-CT and the corresponding values quantified in decalcified sections. Similarly, there were no differences between the results from micro-CT and the analysis of the corresponding ground sections. Histomorphometric studies based on relatively low numbers of undecalcified ground sections or demineralized paraffin sections of bone yield data on bone volume and the thickness of cortical compact bone that is comparable with three-dimensional micro-CT examination. The pilot data on the variability of cortical compact bone and trabecular bone volumes in the porcine major trochanter provided in this study aim for planning experiments in the field of bone healing and implantology.
Collapse
Affiliation(s)
- Tereza Kubíková
- Department of Histology and Embryology and Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic.
| | - Martin Bartoš
- Institute of Dental Medicine, First Faculty of Medicine, Charles University, and General University Hospital, Prague, Czech Republic
| | - Štefan Juhas
- PIGMOD Centre, Laboratory of Cell Regeneration and Plasticity, Institute of Animal Physiology and Genetics, Czech Academy of Sciences, Libechov, Czech Republic
| | - Tomáš Suchý
- Department of Composites and Carbon Materials, Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, Prague, Czech Republic; Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, CTU in Prague, Prague, Czech Republic
| | - Pavla Sauerová
- Department of Histology and Embryology and Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic; Institute of Pathological Physiology, 1st Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Marie Hubálek-Kalbáčová
- Department of Histology and Embryology and Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic; Institute of Pathological Physiology, 1st Faculty of Medicine, Charles University, Prague, Czech Republic
| | - Zbyněk Tonar
- Department of Histology and Embryology and Biomedical Centre, Faculty of Medicine in Pilsen, Charles University, Pilsen, Czech Republic
| |
Collapse
|
2
|
Endres S, Wilke M, Knöll P, Frank H, Kratz M, Wilke A. Correlation of in vitro and in vivo results of vacuum plasma sprayed titanium implants with different surface topography. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:1117-25. [PMID: 17701309 DOI: 10.1007/s10856-007-3086-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2006] [Accepted: 05/02/2007] [Indexed: 05/16/2023]
Abstract
Research has proven that rough surfaces improve both biologic and biomechanical responses to titanium (Ti) implants. The purpose of this study was to evaluate the correlation between the expression of bone cell-associated proteins to Vacuum Plasma-Sprayed Titanium implants (VPS-Ti) with different surface textures in vitro and the bone integration in vivo. The biological performances of the surfaces were evaluated over a period of 8 weeks using human bone marrow cell cultures and Göttinger mini pigs. Cells were cultured on VPS-Ti with two respectively different surface-roughnesses (Ra). The level of Osteoprotegerin (OPG), Osteocalcin (OC) and alkaline phosphatase activity (ALP) were evaluated. The bone integration in vivo was evaluated by histomorphological analyses. A cancellous structured titanium (CS-Ti) construct was used as reference material in both study designs. Comparison of data was conducted using the Scheffé tests and the paired t-test with Bonferroni's correction. A comparative analysis was done to measure the degree of association between the in vitro and in vivo data. A total amount of OC was significantly increased for VPS-Ti for cells cultured on both VPS-Ti and CS-Ti, while OPG was only detectable after 8 weeks without any significant differences. The ALP activity on all surfaces was not statistically increased. For VPS-Ti with Ra ranging from 0.025 mm up to 0.059 mm, bone integration response was increased, but there was no statistical difference between the VPS-Ti. Expression of OPG, OC and ALP correlated with the histomorphological data over the 8-week period. The in vitro data suggest the superiority of VPS-Ti over CS-Ti, but more importantly, the biocompatibility of testing an in vitro model to predict the outcome and possible integration of implants in vivo.
Collapse
Affiliation(s)
- Stefan Endres
- Department of Orthopaedic Surgery, Elisabeth-Klinik GmbH Bigge/Olsberg, Heinrich-Sommer-Str. 4, 59939, Olsberg, Germany.
| | | | | | | | | | | |
Collapse
|