Ferraro S, Dave A, Cereda C, Verduci E, Marcovina S, Zuccotti G. Space research to explore novel biochemical insights on Earth. Clin Chim Acta 2024; 558:119673. [PMID: 38621588 DOI: 10.1016/j.cca.2024.119673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 04/11/2024] [Accepted: 04/12/2024] [Indexed: 04/17/2024]
Abstract
Travel to space has overcome unprecedent technological challenges and this has resulted in transfer of these technological results on Earth to better our lives. Health technology, medical devices, and research advancements in human biology are the first beneficiaries of this transfer. The real breakthrough came with the International Space Station, which endorsed multidisciplinary international scientific collaborations and boosted the research on pathophysiological adaptation of astronauts to life on space. These studies evidenced that life in space appeared to have exposed the astronauts to an accelerated aging-related pathophysiological dysregulation across multiple systems. In this review we emphasize the interaction between several biomarkers and their alteration in concentrations/expression/function by space stress factors. These altered interactions, suggest that different biochemical and hormonal factors, and cell signals, contribute to a complex network of pathophysiological mechanisms, orchestrating the homeostatic dysregulation of various organs/metabolic pathways. The main effects of space travel on altering cell organelles biology, ultrastructure, and cross-talk, have been observed in cell aging as well as in the disruption of metabolic pathways, which are also the causal factor of rare inherited metabolic disorders, one of the major pediatric health issue. The pathophysiologic breakthrough from space research could allow the development of precision health both on Earth and Space by promoting the validation of improved biomarker-based risk scores and the exploration of new pathophysiologic hypotheses and therapeutic targets. Nonstandard abbreviations: International Space Station (ISS), Artificial Intelligence (AI), European Space Agency (ESA), National Aeronautics and Space Agency (NASA), Low Earth Orbit (LEO), high sensitive troponin (hs-cTn), high sensitive troponin I (hs-cTn I), high sensitive troponin T, Brain Natriuretic Peptide (BNP), N terminal Brain Natriuretic Peptide (NT-BNP), cardiovascular disease (CVD), parathyroid hormone (PTH), urinary hydroxyproline (uHP), urinary C- and N-terminal telopeptides (uCTX and uNTX), pyridinoline (PYD), deoxypyridinoline (DPD), half-time (HF), serum Bone Alkaline Phosphatase (sBSAP), serum Alkaline Phosphatase (sAP), Carboxy-terminal Propeptide of Type 1 Procollagen (P1CP), serum Osteocalcin (sOC)), advanced glycation end products (AGEs), glycated hemoglobin A1c (HbA1c), Insulin-like growth factor 1 (IGF1), Growth Hormone (GH), amino acid (AA), β-hydroxy-β methyl butyrate (HMB), maple syrup urine disease (MSUD), non-communicable diseases (NCDs).
Collapse
Affiliation(s)
- Simona Ferraro
- Department of Pediatrics, Buzzi Children's Hospital, Milan, Italy.
| | - Anilkumar Dave
- Space Economy and Open Innovation, Darwix srl, Venice, Italy
| | - Cristina Cereda
- Department of Pediatrics, Buzzi Children's Hospital, Milan, Italy; Center of Functional Genomics and Rare Diseases
| | - Elvira Verduci
- Department of Health Sciences, University of Milan, Milan, Italy; Metabolic Diseases Unit, Department of Pediatrics, Buzzi Children's Hospital, Milan, Italy
| | | | - Gianvincenzo Zuccotti
- Department of Pediatrics, Buzzi Children's Hospital, Milan, Italy; Department of Biomedical and Clinical Science, University of Milan, Milan, Italy
| |
Collapse
|
2
|
Ferraro S, Biganzoli E, Mannarino S, Lanzoni M, Zuccotti G, Plebani M, Kavsak P. High-Sensitivity Cardiac Troponin and the Management of Congenital Heart Disease in Newborns and Infants. Clin Chem 2024; 70:486-496. [PMID: 38180125 DOI: 10.1093/clinchem/hvad215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 10/05/2023] [Indexed: 01/06/2024]
Abstract
BACKGROUND Early cardiac interventions in newborns and infants suspected for congenital heart disease (CHD) decrease morbidity and mortality. After updating current evidence on the use of cardiac troponins (cTn) in the context of CHD for risk stratification at early ages, we discuss relevant issues, starting from the evidence that only the measurement of the cTnT form is useful in this population. CONTENT In newborns/infants with CHD, the cTnT concentration increase is correlated with: (a) cardiac stress and hemodynamic parameters, but not with the type of CHD; (b) volume overload/right ventricular pressure overload; (c) postoperative hypoperfusion injury and mortality; and (d) effects of cardioprotective strategies. For infants with CHD, high-sensitivity cTnT (hs-cTnT) concentrations >25 ng/L are an independent predictor of poor outcomes. Transitioning from cTnT to hs-cTnT in newborns/infants improves the identification of: (a) physiopathological mechanisms and factors that increased hs-cTnT early after birth; (b) myocardial injury, even when subclinical; (c) identification of patients requiring immediate therapeutic interventions; and (d) 99th percentile upper reference limits (URLs). However, no reliable URLs are currently available to allow the detection of myocardial injury associated with CHD in newborns/infants. SUMMARY Additional data evaluating the clinical value of hs-cTnT in the risk stratification of newborns/infants with CHD who may suffer myocardial injury is needed. Validating the measurement, possibly in amniotic fluid samples, and improving the interpretation of hs-cTnT concentrations in the prenatal period, at birth and within 1 year of age are crucial to change CHD mortality/morbidity trends in the pediatric population.
Collapse
Affiliation(s)
- Simona Ferraro
- Department of Pediatrics, Center of Functional Genomics and Rare Diseases, Buzzi Children's Hospital, Milan, Italy
- Pediatric Department, Buzzi Children's Hospital, Milan, Italy
| | - Elia Biganzoli
- Unit of Medical Statistics, Bioinformatics and Epidemiology, University of Milan, Milan, Italy
- Data Science Research Center, University of Milan, Milan, Italy
| | - Savina Mannarino
- Pediatric Cardiology Unit, Buzzi Children's Hospital, Milan, Italy
| | - Monica Lanzoni
- Epidemiology Unit, Territorial Healthcare Agency Insubria Varese, Varese, Italy
| | - Gianvincenzo Zuccotti
- Pediatric Department, Buzzi Children's Hospital, Milan, Italy
- Clinical Science, University of Milan, Milan, Italy
| | - Mario Plebani
- Department of Medicine-DIMED, University of Padova, Padova, Italy
| | - Peter Kavsak
- Department of Pathology and Molecular Medicine, McMaster University, Hamiton, ON, Canada
| |
Collapse
|
3
|
Krintus M, Panteghini M. Judging the clinical suitability of analytical performance of cardiac troponin assays. Clin Chem Lab Med 2023; 61:801-810. [PMID: 36798043 DOI: 10.1515/cclm-2023-0027] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 02/07/2023] [Indexed: 02/18/2023]
Abstract
New millennium diagnostic criteria for acute myocardial infarction precipitated a revolutionary shift from an approach based primarily on electrocardiography and clinical symptoms to a strategy based on biomarkers, and preferably cardiac troponins (cTn) I and T. In the last 20 years, clinical recommendations have strengthened the role of cTn and led to the development of highly sensitive (hs-cTn) assays, which are now leading players in all current clinical practice guidelines. To optimize the clinical use of these hs-cTn assays, focus on their analytical aspects has become increasingly important, emphasizing the need for the establishment of suitable analytical performance by the definition and implementation of appropriate specifications. An accurate estimate of measurement uncertainty, together with the acquisition of the highest analytical quality when very low concentrations of hs-cTn are measured, are essential requirements and should represent a practical laboratory standard in assuring optimal clinical use. Additional goals for further improving the quality of laboratory information should be the establishment of robust data concerning biological variation of cTn and the resolution of practical challenges opposed to the harmonization of cTn I results obtained by differing commercial measuring systems.
Collapse
Affiliation(s)
- Magdalena Krintus
- Department of Laboratory Medicine, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Torun, Poland
| | - Mauro Panteghini
- Department of Biomedical and Clinical Sciences, University of Milan, Milano, Italy
| |
Collapse
|
4
|
Panteghini M, Dolci A, Birindelli S, Szoke D, Aloisio E, Caruso S. Pursuing appropriateness of laboratory tests: a 15-year experience in an academic medical institution. Clin Chem Lab Med 2022; 60:1706-1718. [PMID: 35998662 DOI: 10.1515/cclm-2022-0683] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 08/08/2022] [Indexed: 02/04/2023]
Abstract
Appropriateness in Laboratory Medicine has been the object of various types of interventions. From published experiences, it is now clear that to effectively manage the laboratory test demand it is recommended to activate evidence-based preventative strategies stopping inappropriate requests before they can reach the laboratory. To guarantee appropriate laboratory test utilization, healthcare institutions should implement and optimize a computerized provider order entry (CPOE), exploiting the potential of electronic requesting as "enabling factor" for reinforcing appropriateness and sustaining its effects over time. In our academic institution, over the last 15 years, our medical laboratory has enforced various interventions to improve test appropriateness, all directly or indirectly based on CPOE use. The following types of intervention were implemented: (1) applying specific recommendations supported by monitoring by CPOE as well as a continuous consultation with clinicians (tumour markers); (2) removing outdated tests and avoiding redundant duplications (cardiac markers, pancreatic enzymes); (3) order restraints to selected wards and gating policy (procalcitonin, B-type natriuretic peptide, homocysteine); (4) reflex testing (bilirubin fractions, free prostate-specific antigen, aminotransferases, magnesium in hypocalcemia); and (5) minimum retesting interval (D-Dimer, vitamin B12, C-reactive protein, γ-glutamyltranspeptidase). In this paper, we reviewed these interventions and summarized their outcomes primarily related to the changes in total test volumes and cost savings, without neglecting patient safety. Our experience confirmed that laboratory professionals have an irreplaceable role as "stewards" in designing, implementing, evaluating, and maintaining interventions focused to improving test appropriateness.
Collapse
Affiliation(s)
- Mauro Panteghini
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy.,Dipartimento di Scienze Biomediche e Cliniche, Università degli Studi, Milan, Italy
| | - Alberto Dolci
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy.,Dipartimento di Scienze Biomediche e Cliniche, Università degli Studi, Milan, Italy
| | - Sarah Birindelli
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Dominika Szoke
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Elena Aloisio
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy
| | - Simone Caruso
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco, Milan, Italy
| |
Collapse
|
5
|
Krintus M, Panteghini M. Laboratory-related issues in the measurement of cardiac troponins with highly sensitive assays. Clin Chem Lab Med 2021; 58:1773-1783. [PMID: 32134723 DOI: 10.1515/cclm-2020-0017] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 01/24/2020] [Indexed: 12/13/2022]
Abstract
A number of assay-related issues can affect the performance of cardiac troponin (cTn) measurement in everyday practice. In this respect, it is vital that all information on cTn assays is known and that the performance characteristics of assays are objectively assessed and adequately described. The advent of the latest generation of more sensitive cTn assays has heralded a new wave of information about low concentrations of cTn in blood. These recent generation assays have improved analytical sensitivity and corresponding performance at low cTn concentrations when compared to their predecessors, providing a convincing goal for laboratory medicine in helping clinicians in the diagnosis of acute myocardial infarction. Crucial to the clinical utility of highly sensitive cTn assays is the laboratorians' role in closely scrutinizing proposed assays and defining their value in relation to available evidence. Analytical, as well as pre-analytical and post-analytical, aspects must be documented. In this review, we describe what laboratory professionals should know about their cTn assay performance characteristics and the pre-analytical prerequisites for robustness to ensure optimal post-analytical reporting.
Collapse
Affiliation(s)
- Magdalena Krintus
- Department of Laboratory Medicine, Nicolaus Copernicus University, Collegium Medicum, 9 Sklodowskiej-Curie Street, 85-094 Bydgoszcz, Poland, Phone: +48 52 585 44 90, Fax: +48 52 585 36 03
| | - Mauro Panteghini
- Department of Biomedical and Clinical Sciences 'Luigi Sacco', University of Milan, Milan, Italy
| |
Collapse
|
6
|
Braga F, Aloisio E, Panzeri A, Nakagawa T, Panteghini M. Analytical validation of a highly sensitive point-of-care system for cardiac troponin I determination. ACTA ACUST UNITED AC 2019; 58:138-145. [DOI: 10.1515/cclm-2019-0801] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Accepted: 09/22/2019] [Indexed: 12/28/2022]
Abstract
Abstract
Background
Highly sensitive cardiac troponin assays (hs-cTn) are not available as point-of-care (POC) measurements. As rapid testing cannot be achieved at the expense of clinical performance, there is an urgent need to develop and rigorously validate POC hs-cTn. Konica Minolta (KM) has recently developed a surface plasmon-field enhanced fluorescence spectroscopy-based POC hs-cTn I system.
Methods
We validated the analytical characteristics of the KM POC system according to the international guidelines.
Results
Limit of blank (LoB) and limit of detection (LoD) were 0.35 and 0.62 ng/L, respectively, hs-cTn I concentrations corresponding to a total CV of 20%, 10% and 5% were 1.5, 3.9 and 11.0 ng/L, respectively. Method comparison studies showed that KM calibration was successfully traced to higher-order references. Limit of quantitation (LoQ), i.e. the hs-cTn I concentration having a total error of measurement of ≤34%, was 10.0 ng/L. The upper reference limit (URL) for 600 healthy blood donors was calculated at 12.2 ng/L (90% confidence interval [CI]: 9.2–39.2), while sex-partitioned URLs were 20.6 (males) and 10.7 ng/L (females), respectively (p < 0.0001). KM assay measured hs-cTn I concentrations >LoD in 65.7% of all reference individuals, in 76.7% of males and in 54.7% of females, respectively.
Conclusions
The KM system joins the characteristics of POC systems to the analytical performance of hs-cTn.
Collapse
Affiliation(s)
- Federica Braga
- Department of Biomedical and Clinical Sciences ‘Luigi Sacco’ , Università di Milano , Milan , Italy
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco , Via GB Grassi 74 , 20157 Milano , Italy , Phone: +390239042743, Fax: +390250319835
| | - Elena Aloisio
- Department of Biomedical and Clinical Sciences ‘Luigi Sacco’ , Università di Milano , Milan , Italy
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco , Milano , Italy
| | - Andrea Panzeri
- Department of Biomedical and Clinical Sciences ‘Luigi Sacco’ , Università di Milano , Milan , Italy
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco , Milano , Italy
| | - Takahito Nakagawa
- Konica Minolta, Inc., Project Promotion Department , Product Planning Division, Precision Medicine Business Unit , Tokyo , Japan
| | - Mauro Panteghini
- Department of Biomedical and Clinical Sciences ‘Luigi Sacco’ , Università di Milano , Milan , Italy
- UOC Patologia Clinica, ASST Fatebenefratelli-Sacco , Milano , Italy
| |
Collapse
|
7
|
Panteghini M. How Clinical Laboratories May Improve Their Performance: The “High-Sensitivity” Troponin Paradigm. Clin Chem 2018; 64:621-623. [DOI: 10.1373/clinchem.2017.285577] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 01/02/2018] [Indexed: 11/06/2022]
Affiliation(s)
- Mauro Panteghini
- Department of Biomedical and Clinical Sciences Luigi Sacco, University of Milan Medical School, Milan, Italy
| |
Collapse
|
8
|
Lippi G, Ferrari A, Gandini G, Gelati M, Lo Cascio C, Salvagno GL. Analytical evaluation of the new Beckman Coulter Access high sensitivity cardiac troponin I immunoassay. Clin Chem Lab Med 2017; 56:157-161. [PMID: 28704179 DOI: 10.1515/cclm-2017-0350] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Accepted: 06/01/2017] [Indexed: 01/08/2023]
Abstract
BACKGROUND This study was aimed to evaluate the analytical performance of the novel chemiluminescent and fully-automated Beckman Coulter Access hsTnI high-sensitivity immunoassay for measurement of cardiac troponin I (cTnI). METHODS The study, using lithium heparin samples, included assessment of limit of blank (LOB), limit of detection (LOD), functional sensitivity, linearity, imprecision (within run, between-run and total), calculation of 99th percentile upper reference limit (URL) in 175 healthy blood donors (mean age, 36±12 years; 47% women) and comparison with two other commercial cTnI immunoassays. RESULTS The LOB, LOD and functional sensitivity of Access hsTnI were 0.14, 0.34 and 1.35 ng/L, respectively. The within-run, between-run and total imprecision was 2.2%-2.9%, 4.6%-5.4%, and 5.4%-6.1%, respectively. The linearity was excellent in the range of cTnI values between 0.95 and 4195 ng/L (r=1.00). The 99th percentile URL was 15.8 ng/L. Measurable cTnI values were found in 173/175 healthy subjects (98.9%). Good agreement of cTnI values was found with AccuTnI+3 (r=0.97; mean bias, -9.3%), whereas less satisfactory agreement was found with Siemens Dimension Vista cTnI (r=0.95; mean bias, -55%). CONCLUSIONS The results of our evaluation of the Beckman Coulter Access hsTnI indicate that the analytical performance of this fully-automated immunoassay is excellent.
Collapse
|
9
|
Ferraro S, Panteghini M. The role of laboratory in ensuring appropriate test requests. Clin Biochem 2017; 50:555-561. [PMID: 28284827 DOI: 10.1016/j.clinbiochem.2017.03.002] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2017] [Revised: 03/03/2017] [Accepted: 03/04/2017] [Indexed: 12/15/2022]
Abstract
This review highlights the role of laboratory professionals and the strategies to be promoted in strict cooperation with clinicians for auditing, monitoring and improving the appropriateness of test request. The introduction of local pathways and care maps in agreement with international and national guidelines as well as the implementation of reflex testing and algorithms have a central role in guiding test request and in correcting the overuse/misuse of tests. Furthermore, removing obsolete tests from laboratory menu and vetting of restricted tests is recommended to increase cost-effectiveness. This saves costs and permits to introduce new biomarkers with increased diagnostic accuracy with a better impact on patient outcome. An additional issue is concerning the periodicity of (re)testing, accounting that only a minority of tests may be ordered as often as necessary. In the majority of cases, a minimum retesting interval should be introduced. The availability of effective computerised order entry systems is relevant in ensuring appropriate test requests and in providing an aid by automated rules that may stop inappropriate requests before they reach the laboratory.
Collapse
Affiliation(s)
- Simona Ferraro
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, University of Milan, Milan, Italy.
| | - Mauro Panteghini
- Clinical Pathology Unit, 'Luigi Sacco' University Hospital, University of Milan, Milan, Italy; Department of Biomedical and Clinical Sciences, University of Milan, Milan, Italy
| |
Collapse
|
10
|
Erdal EP, Mitra D, Khangulov VS, Church S, Plokhoy E. The economic impact of poor sample quality in clinical chemistry laboratories: results from a global survey. Ann Clin Biochem 2016; 54:230-239. [PMID: 27166314 DOI: 10.1177/0004563216651647] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Background Despite advances in clinical chemistry testing, poor blood sample quality continues to impact laboratory operations and the quality of results. While previous studies have identified the preanalytical causes of lower sample quality, few studies have examined the economic impact of poor sample quality on the laboratory. Specifically, the costs associated with workarounds related to fibrin and gel contaminants remain largely unexplored. Methods A quantitative survey of clinical chemistry laboratory stakeholders across 10 international regions, including countries in North America, Europe and Oceania, was conducted to examine current blood sample testing practices, sample quality issues and practices to remediate poor sample quality. Survey data were used to estimate costs incurred by laboratories to mitigate sample quality issues. Results Responses from 164 participants were included in the analysis, which was focused on three specific issues: fibrin strands, fibrin masses and gel globules. Fibrin strands were the most commonly reported issue, with an overall incidence rate of ∼3%. Further, 65% of respondents indicated that these issues contribute to analyzer probe clogging, and the majority of laboratories had visual inspection and manual remediation practices in place to address fibrin- and gel-related quality problems (55% and 70%, respectively). Probe maintenance/replacement, visual inspection and manual remediation were estimated to carry significant costs for the laboratories surveyed. Annual cost associated with lower sample quality and remediation related to fibrin and/or gel globules for an average US laboratory was estimated to be $100,247. Conclusions Measures to improve blood sample quality present an important step towards improved laboratory operations.
Collapse
Affiliation(s)
- Erik P Erdal
- 1 Becton Dickinson and Company, Franklin Lakes, NJ, USA
| | | | | | | | | |
Collapse
|