1
|
Liu X, Du X, Huang Y, Pang B, Zhang M, Ma Y, Wang X, Song X, Li J, Li J. Rapid detection of four pathogens in bloodstream infection by antimicrobial peptide capture combined with multiplex PCR and capillary electrophoresis. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
2
|
Gómez J, Melón S, Boga JA, Alvarez-Argüelles ME, Rojo-Alba S, Leal-Negredo A, Castello-Abietar C, Alvarez V, Cuesta-Llavona E, Coto E. Capillary electrophoresis of PCR fragments with 5´-labelled primers for testing the SARS-Cov-2. J Virol Methods 2020; 284:113937. [PMID: 32659241 PMCID: PMC7351060 DOI: 10.1016/j.jviromet.2020.113937] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 07/07/2020] [Accepted: 07/08/2020] [Indexed: 11/28/2022]
Abstract
Due to the huge demand for SARS-Cov-2 determination,alternatives to the standard qtPCRtestsare potentially useful for increasing the number of samples screened. Our aim was to develop a direct fluorescent PCR capillary-electrophoresis detection of the viral genome. We validated this approach on several SARS-Cov-2 positive and negative samples.We isolated the naso-pharingealRNA from 20 positive and 10 negative samples. The cDNA was synthesised and two fragments of the SARS-Cov-2 were amplified. One of the primers for each pair was 5´-end fluorochrome labelled. The amplifications were subjected to capillary electrophoresis in ABI3130 sequencers to visualize the fluorescent peaks.The two SARS-Cov-2 fragments were successfully amplified in the positive samples, while the negative samples did not render fluorescent peaks. In conclusion, we describe and alternative method to identify the SARS-Cov-2 genome that could be scaled to the analysis of approximately 100 samples in less than 5 h. By combining a standard PCR with capillary electrophoresis our approach would overcome the limits imposed to many labs by the qtPCR and increase the testing capacity.
Collapse
Affiliation(s)
- Juan Gómez
- Genética Molecular, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain; Red de Investigación Renal (REDINREN), Madrid, Spain.
| | - Santiago Melón
- Microbiología, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - José A Boga
- Microbiología, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - Marta E Alvarez-Argüelles
- Microbiología, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - Susana Rojo-Alba
- Microbiología, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | | | | | - Victoria Alvarez
- Genética Molecular, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - Elías Cuesta-Llavona
- Genética Molecular, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain
| | - Eliecer Coto
- Genética Molecular, Hospital Universitario Central Asturias, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, ISPA, Oviedo, Spain; Departamento Medicina, Universidad de Oviedo, Oviedo, Spain; Red de Investigación Renal (REDINREN), Madrid, Spain.
| |
Collapse
|
3
|
Abstract
Several techniques are currently available to quickly and accurately quantify the number of virus particles in a sample, taking advantage of advanced technologies improving old techniques or generating new ones, generally relying on partial detection methods or structural analysis. Therefore, characterization of virus infectivity in a sample is often essential, and classical virological methods are extremely powerful in providing accurate results even in an old-fashioned way. In this chapter, we describe in detail the techniques routinely used to estimate the number of viable infectious coronavirus particles in a given sample. All these techniques are serial dilution assays, also known as titrations or end-point dilution assays (EPDA).
Collapse
|
4
|
Walper SA, Lasarte Aragonés G, Sapsford KE, Brown CW, Rowland CE, Breger JC, Medintz IL. Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies. ACS Sens 2018; 3:1894-2024. [PMID: 30080029 DOI: 10.1021/acssensors.8b00420] [Citation(s) in RCA: 88] [Impact Index Per Article: 12.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Although a fundamental understanding of the pathogenicity of most biothreat agents has been elucidated and available treatments have increased substantially over the past decades, they still represent a significant public health threat in this age of (bio)terrorism, indiscriminate warfare, pollution, climate change, unchecked population growth, and globalization. The key step to almost all prevention, protection, prophylaxis, post-exposure treatment, and mitigation of any bioagent is early detection. Here, we review available methods for detecting bioagents including pathogenic bacteria and viruses along with their toxins. An introduction placing this subject in the historical context of previous naturally occurring outbreaks and efforts to weaponize selected agents is first provided along with definitions and relevant considerations. An overview of the detection technologies that find use in this endeavor along with how they provide data or transduce signal within a sensing configuration follows. Current "gold" standards for biothreat detection/diagnostics along with a listing of relevant FDA approved in vitro diagnostic devices is then discussed to provide an overview of the current state of the art. Given the 2014 outbreak of Ebola virus in Western Africa and the recent 2016 spread of Zika virus in the Americas, discussion of what constitutes a public health emergency and how new in vitro diagnostic devices are authorized for emergency use in the U.S. are also included. The majority of the Review is then subdivided around the sensing of bacterial, viral, and toxin biothreats with each including an overview of the major agents in that class, a detailed cross-section of different sensing methods in development based on assay format or analytical technique, and some discussion of related microfluidic lab-on-a-chip/point-of-care devices. Finally, an outlook is given on how this field will develop from the perspective of the biosensing technology itself and the new emerging threats they may face.
Collapse
Affiliation(s)
- Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Guillermo Lasarte Aragonés
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Kim E. Sapsford
- OMPT/CDRH/OIR/DMD Bacterial Respiratory and Medical Countermeasures Branch, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Carl W. Brown
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Clare E. Rowland
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- National Research Council, Washington, D.C. 20036, United States
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| |
Collapse
|
5
|
Lian DS, Zeng HS. Capillary Electrophoresis Based on Nucleic Acid Detection as Used in Food Analysis. Compr Rev Food Sci Food Saf 2017; 16:1281-1295. [DOI: 10.1111/1541-4337.12297] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 07/14/2017] [Accepted: 07/19/2017] [Indexed: 12/21/2022]
Affiliation(s)
- Dong-Sheng Lian
- Guangzhou Women and Children's Medical Center of Guangzhou Medical University; NO. 9 at Jinsui Rd., Tianhe District Guangzhou Guangdong China
| | - Hua-Song Zeng
- Guangzhou Women and Children's Medical Center of Guangzhou Medical University; NO. 9 at Jinsui Rd., Tianhe District Guangzhou Guangdong China
| |
Collapse
|
6
|
Zhu Q, Zhang Q, Zhang N, Gong M. Alternate injections coupled with flow-gated capillary electrophoresis for rapid and accurate quantitative analysis of urine samples. Anal Chim Acta 2017; 978:55-60. [PMID: 28595727 PMCID: PMC5522808 DOI: 10.1016/j.aca.2017.04.044] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Revised: 04/24/2017] [Accepted: 04/27/2017] [Indexed: 01/12/2023]
Abstract
Capillary electrophoresis (CE) is a powerful separation technique with advantages over HPLC in terms of separation efficiency, speed, and cost. However, CE suffers in poor reproducibility in quantitative chemical analysis, which is one of major drawbacks preventing its widespread use in routine analytical laboratories. Here we report a novel strategy to enhance the quantitative capability of flow-gated CE. The platform integrated dual flow branches to respectively supply a sample and its standard additions that were then alternately injected into a single capillary for rapid separations (typically 20-90 s). A micro-fabricated switch was used to enable the alternate injections. It was assumed that the analytical system maintained constant conditions during neighboring injections that served as external self-standards for quantitation. This strategy was expected to reduce uncertainties caused by the fluctuation in capillary conditions and the drift of detection systems. Experimental results demonstrated that the dual-branch flow-gated CE coupled with alternate injections significantly improved the reproducibility with respect to peak height ratios under deliberate variations in injection volumes, separation voltages, optical focusing, and laser power; and thus the interday precision was ensured. To demonstrate its applicability, cyanide and amino acids in human urine were quantified rapidly with the one-point standard addition method after fluorogenic derivatization with naphthalene-2,3-dicarboxaldehyde (NDA), and the measurement accuracy was validated by determining the recovery of standard cyanide added to a urinary matrix. This strategy would be valuable to enable the quantitative capability of flow-gated CE in the measurements of a broad range of analytes, especially those lacking suited internal standards.
Collapse
Affiliation(s)
- Qingfu Zhu
- Department of Chemistry, Wichita State University, Wichita, KS 67260, United States
| | - Qiyang Zhang
- Department of Chemistry, Wichita State University, Wichita, KS 67260, United States
| | - Ning Zhang
- Department of Chemistry, Wichita State University, Wichita, KS 67260, United States
| | - Maojun Gong
- Department of Chemistry, Wichita State University, Wichita, KS 67260, United States.
| |
Collapse
|