1
|
Murray J, Kok KB, Ayling RM. Fecal Calprotectin in Gastrointestinal Disease. Clin Chem 2023:7179811. [PMID: 37228058 DOI: 10.1093/clinchem/hvad051] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 03/14/2023] [Indexed: 05/27/2023]
Abstract
BACKGROUND Inflammatory bowel disease (IBD) comprises a group of chronic conditions characterized by relapsing and remitting inflammation of the gastrointestinal tract. The incidence is increasing worldwide, and the therapeutic options for management are expanding. Endoscopy is the gold standard investigation for diagnosis of IBD and for assessing mucosal healing, which is increasingly being used as a measure of disease control. However, it is an invasive procedure that is unpleasant for patients and expensive and time-consuming for hospitals. Fecal calprotectin has been shown to be an accurate surrogate marker of gastrointestinal inflammation in IBD. CONTENT Fecal calprotectin was initially used for the diagnosis of IBD but is now recognized as having a role in assisting in assessment of disease activity, prediction of relapse, and informing decisions around therapy and may help to minimize requirement for endoscopy. However, there are various preanalytical and analytical factors that can affect interpretation of the results; these need to be understood to optimize clinical care. SUMMARY Preanalytical and analytical factors that can potentially influence fecal calprotectin concentrations are examined, and an overview is provided of clinical situations in which fecal calprotectin is commonly measured.
Collapse
Affiliation(s)
- Jennifer Murray
- Department of Gastroenterology, Barts Health NHS Trust, Royal London Hospital, London, United Kingdom
| | - Klaartje B Kok
- Department of Gastroenterology, Barts Health NHS Trust, Royal London Hospital, London, United Kingdom
| | - Ruth M Ayling
- Department of Clinical Biochemistry, Barts Health NHS Trust, Royal London Hospital, London, United Kingdom
| |
Collapse
|
2
|
Dijkhuis LEJL, Crouwel F, Duijvestein M, Buiter HJC, de Boer NK, Hamer HM. The Reliability of Patient-Performed Fecal Calprotectin Testing in Inflammatory Bowel Disease. J Appl Lab Med 2023; 8:319-329. [PMID: 36512478 DOI: 10.1093/jalm/jfac078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 08/05/2022] [Indexed: 12/15/2022]
Abstract
BACKGROUND Home use of a buffer-containing extraction device for fecal calprotectin determination can bypass the labor-intensive extraction procedure and potentially prevent degradation at room temperature. METHODS In this prospective cross-sectional observational study, 2 CALiaGold tubes (extraction device) and one native tube were filled from the same bowel movement by patients with inflammatory bowel disease. Afterwards patients completed a questionnaire including whether they preferred the extraction device or the normal sampling method. All tubes were sent to the laboratory and when they arrived, 2 more CALiaGold tubes were filled at the laboratory from the native sample. The fecal calprotectin concentrations in all tubes were measured by a particle-enhanced turbidimetric immunoassay. RESULTS Fifty-three patients were included in the study. Fecal calprotectin levels were significantly higher in samples extracted by the patient compared to the analyst-performed extractions. When patients were divided into 3 groups (i.e., fecal calprotectin levels <50 ug/g, 50 to 200 µg/g, and >200 µg/g) a substantial concordance was found (Cohen kappa 0.654). Patients sampling imprecision was higher (P < 0.018, median CV 16%) compared to the analyst. Most patients preferred this extraction device. CONCLUSIONS Patient-performed fecal calprotectin extraction seems a realistic alternative sampling method and is preferred by most patients.
Collapse
Affiliation(s)
- Lies E J L Dijkhuis
- Department of Gastroenterology and Hepatology, Amsterdam Gastroenterology Endocrinology Metabolism research institute, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Femke Crouwel
- Department of Gastroenterology and Hepatology, Amsterdam Gastroenterology Endocrinology Metabolism research institute, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Marjolijn Duijvestein
- Department of Gastroenterology and Hepatology, Amsterdam Gastroenterology Endocrinology Metabolism research institute, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.,Department of Gastroenterology and Hepatology, Radboud University Medical Centre, Nijmegen, the Netherlands
| | - Hans J C Buiter
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Nanne K de Boer
- Department of Gastroenterology and Hepatology, Amsterdam Gastroenterology Endocrinology Metabolism research institute, Amsterdam University Medical Centers, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Henrike M Hamer
- Department of Clinical Chemistry, Amsterdam University Medical Centers, Amsterdam Gastroenterology Endocrinology Metabolism Research Institute, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| |
Collapse
|
3
|
The Use of Fecal Calprotectin Testing in Paediatric Disorders: A Position Paper of the European Society for Paediatric Gastroenterology and Nutrition Gastroenterology Committee. J Pediatr Gastroenterol Nutr 2021; 72:617-640. [PMID: 33716293 DOI: 10.1097/mpg.0000000000003046] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
OBJECTIVES The aim of the study was to review the evidence regarding the clinical use and value of fecal calprotectin (FC) measurements in different gastrointestinal disorders in children. METHODS A literature search was conducted in the PubMed, MEDLINE, EMBASE, and Cochrane databases until October 31, 2019. Subtopics were identified and each assigned to individual authors. RESULTS A total of 28 recommendations were voted on using the nominal voting technique. Recommendations are given related to sampling, measurement methods, and results interpretation. The 14 authors anonymously voted on each recommendation using a 9-point scale (1 strongly disagree to 9 fully agree). Consensus was considered achieved if at least 75% of the authors voted 6, 7, 8, or 9. CONCLUSIONS Consensus was reached for all recommendations. Limitations for the use of FC in clinical practice include variability in extraction methodology, performance of test kits as well as the need to establish local reference ranges because of the influence of individual factors, such as age, diet, microbiota, and drugs. The main utility of FC measurement at present is in the diagnosis and monitoring of inflammatory bowel disease (IBD) as well as to differentiate it from functional gastrointestinal disorders (FAPDs). FC, however, has neither utility in the diagnosis of infantile colic nor to differentiate between functional and organic constipation. A rise in FC concentration, may alert to the risk of developing necrotizing enterocolitis and help identifying gastrointestinal involvement in children with Henoch-Schönlein purpura. FC measurement is of little value in Cow's Milk Protein Allergy, coeliac disease (CD), and cystic fibrosis. FC does neither help to distinguish bacterial from viral acute gastroenteritis (AGE), nor to diagnose Helicobacter Pylori infection, small intestinal bacterial overgrowth (SIBO), acute appendicitis (AA), or intestinal polyps.
Collapse
|
4
|
D'Amico F, Nancey S, Danese S, Peyrin-Biroulet L. A Practical Guide for Faecal Calprotectin Measurement: Myths and Realities. J Crohns Colitis 2021; 15:152-161. [PMID: 32392336 DOI: 10.1093/ecco-jcc/jjaa093] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND AND AIMS Faecal calprotectin [FC] is a valid and non-invasive marker of mucosal inflammation. It is widely used both in clinical trials and in daily clinical practice for patients with inflammatory bowel diseases, but currently no accepted standardization for FC testing is available. Our primary aim here was to provide a clinician's guide containing all the practical information on FC measurement in order to avoid any confounding factors, to minimize intra- and inter-individual variability in dosage, and to ensure a better and adequate interpretation of the results. METHODS We conducted a detailed search of the scientific literature in the PubMed/MEDLINE, EMBASE and Cochrane databases up to January 2020 to find all relevant and available articles on pre-analytical and analytical phases of FC measurement. RESULTS FC testing is a multi-step procedure consisting of a pre-analytical phase aimed to collect and process the stool sample and a subsequent analytical phase of FC measurement. Several factors can influence test results determining false positives or false negatives. Importantly, this faecal marker is mostly used for patient follow-up and as a predictor of treatment response. For this reason, any altered data may affect the physicians' decisions, negatively impacting on patient management. CONCLUSIONS This review provides for the first time practical advice to minimize dosage variability, although further dedicated studies are needed to compare commercially available tests and identify the best tools for the most precise and accurate FC measurement.
Collapse
Affiliation(s)
- Ferdinando D'Amico
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.,Department of Gastroenterology and Inserm NGERE U1256, University Hospital of Nancy, University of Lorraine, Vandoeuvre-lès-Nancy, France
| | - Stéphane Nancey
- Department of Gastroenterology, Hospices Civils de Lyon, Lyon-Sud Hospital, Pierre Benite, and Inserm U1111, CIRI, Lyon, France
| | - Silvio Danese
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.,IBD Center, Department of Gastroenterology, Humanitas Research Hospital, Rozzano -IRCCS-, Milan, Italy
| | - Laurent Peyrin-Biroulet
- Department of Gastroenterology and Inserm NGERE U1256, University Hospital of Nancy, University of Lorraine, Vandoeuvre-lès-Nancy, France
| |
Collapse
|
5
|
Juricic G, Brencic T, Tesija-Kuna A, Njegovan M, Honovic L. Faecal calprotectin determination: impact of preanalytical sample treatment and stool consistency on within- and between-method variability. Biochem Med (Zagreb) 2019; 29:010707. [PMID: 30799976 PMCID: PMC6366951 DOI: 10.11613/bm.2019.010707] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2018] [Accepted: 12/21/2018] [Indexed: 12/17/2022] Open
Abstract
Introduction We assessed the differences in faecal calprotectin (FC) concentrations measured by two assays depending on the stool consistency and extraction method. Materials and methods Stool samples were extracted using the EliA Stool Extraction Kit, Calex® Cap extraction device and respective weighing methods, while FC concentrations were measured using the EliATM Calprotectin and Bühlmann fCAL® Turbo method and checked for within- and between-method variability with regard to extraction method and stool consistency category. Extraction yield was evaluated for impact of different sample incubation time (10 min and 1 h) in extraction buffer for both methods and for impact of different initial sample dilutions (1:50, 1:100, 1:500) for fCAL® Turbo method. Results Results determined from Calex® Cap extracts were higher compared to weighing method extracts (mean bias 33.3%; P < 0.001), while no significant difference was found between results obtained with EliA Stool Extraction Kit and weighing method (mean bias 0.1%; P = 0.484), in both cases irrespective of stool consistency. Bühlmann fCAL® Turbo results were higher than EliATM Calprotectin results (mean bias 32.3%, P = 0.025 weighing method; and mean bias 53.9%, P < 0.001 extraction devices), the difference is dependent on stool consistency and FC concentration. Significantly higher FC extraction yield was obtained with longer sample incubation time for both methods (P = 0.019 EliATM Calprotectin; P < 0.001 fCAL® Turbo) and with increasing initial sample dilution for fCAL® Turbo method (P < 0.001). Conclusion Preanalytical stool sample handling proved to be a crucial factor contributing to within- and between-FC assay variability. Standardization is urgently needed in order to assure comparable and reliable FC results.
Collapse
Affiliation(s)
- Gordana Juricic
- Department of Laboratory Diagnostics, General Hospital Pula, Pula, Croatia
| | - Tina Brencic
- Department of Laboratory Diagnostics, General Hospital Pula, Pula, Croatia
| | - Andrea Tesija-Kuna
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Milena Njegovan
- Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia
| | - Lorena Honovic
- Department of Laboratory Diagnostics, General Hospital Pula, Pula, Croatia
| |
Collapse
|
6
|
Acevedo D, Salvador MP, Girbes J, Estan N. Fecal Calprotectin: A Comparison of Two Commercial Enzymoimmunoassays and Study of Fecal Extract Stability at Room Temperature. J Clin Med Res 2018; 10:396-404. [PMID: 29581802 PMCID: PMC5862087 DOI: 10.14740/jocmr3275e] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Accepted: 01/19/2018] [Indexed: 02/06/2023] Open
Abstract
Background The aims of the study were: 1) to compare the fecal calprotectin (fCal) assay results with Calprolab™ ELISA (HRP) (Calpro AS) versus our routine method, Elia™ fluoroenzymoimmunoassay (Thermo Fisher), and 2) to determine whether the fCal assay results do not vary following storage of the extract at room temperature for 4 days with the Calpro AS buffer, this being the estimated shipment time from the home of the patient, and an aspect little studied to date. Methods The fCal was determined in 198 patients divided into three groups: inflammatory bowel disease (IBD), organic intestinal disease, and functional intestinal disorders. Fecal extraction was carried out using the Roche Diagnostics kit with the corresponding specific buffers. Results The fCal assay with the Thermo Fisher method was found to be more sensitive but less specific than with the Calpro AS technique. The positive predictive value was low (just over 50%), though the negative predictive value was high (over 90%) with both methods. The likelihood ratios revealed small but occasionally important pre- versus post-test differences. When we compared the two methods, the Spearman correlation coefficient (ρ) was 0.819 (95% CI: 0.768 - 0.860) (P < 0.0001), reflecting a positive correlation. Similarly, when stratifying the fCal results into < 50 µg/g, 50 - 100 µg/g and > 100 µg/g, the resulting Cohen’s kappa coefficient was 0.7766 (95% CI: 0.7025 - 0.8507), reflecting a substantial agreement between both methods. The stability of fCal was high in fecal extracts with the Calpro AS extraction buffer at room temperature for 4 days, which yielded a Spearman correlation coefficient of 0.951 (95% CI: 0.933 - 0.965), when the results were compared to those of the recent extracts (P < 0.0001). Conclusions A positive correlation was observed between the two methods. In view of the high negative predictive value obtained with fCal, the presence of organic disease is highly unlikely in the presence of a normal concentration of this marker. We also confirmed the excellent stability of fCal in fecal extracts with the Calpro AS extraction buffer stored at room temperature. Thus, and for the sake of convenience and hygiene, it would be ideal for the patient to perform the extraction at home.
Collapse
Affiliation(s)
- Delia Acevedo
- Clinical Analysis Service, Dr. Peset University Hospital, Avenida Gaspar Aguilar, 90, 46440 Valencia, Spain
| | - Maria Pilar Salvador
- Clinical Analysis Service, Dr. Peset University Hospital, Avenida Gaspar Aguilar, 90, 46440 Valencia, Spain
| | - Javier Girbes
- Clinical Analysis Service, Dr. Peset University Hospital, Avenida Gaspar Aguilar, 90, 46440 Valencia, Spain
| | - Nuria Estan
- Clinical Analysis Service, Dr. Peset University Hospital, Avenida Gaspar Aguilar, 90, 46440 Valencia, Spain
| |
Collapse
|