1
|
Nagy G, Földesi R, Csípő I, Tarr T, Szűcs G, Szántó A, Bubán T, Szekanecz Z, Papp M, Kappelmayer J, Antal-Szalmás P. A novel way to evaluate autoantibody interference in samples with mixed antinuclear antibody patterns in the HEp-2 cell based indirect immunofluorescence assay and comparison of conventional microscopic and computer-aided pattern recognition. Clin Chim Acta 2024; 553:117747. [PMID: 38154766 DOI: 10.1016/j.cca.2023.117747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/22/2023] [Accepted: 12/25/2023] [Indexed: 12/30/2023]
Abstract
BACKGROUND A major challenge of the HEp-2 cell-based indirect immunofluorescence (IIF) assays is the correct identification of the individual anti-nuclear antibodies (ANAs) if more than one is present in a sample. We created artificial mixes by pooling two different samples with a single autoantibody in different titers. Comparison of the expected and observed patterns and titers clarifies the interference between the two tested ANAs. METHODS Serum samples with a single homogeneous or speckled ANA pattern were serially diluted and mixed in 16 combinations, providing end-point titers of 1:5,120 to 1:80 for both patterns. These mixes were tested by a HEp-2 IIF assay and were evaluated by conventional evaluation, the EUROPattern (EPa) system and on-screen analysis. RESULTS Homogeneous pattern can alter the identification of the speckled pattern much more than vice versa, but both has an interfering effect on the other. The effect of the interfering on the tested pattern was higher if the titer of the former one was higher. The pattern recognition efficacy of conventional and the on-screen evaluation was similar and superior compared to the EPa analysis. CONCLUSIONS The application of artificial mixed samples can help the evaluation of the efficacy of manual and computer-aided ANA HEp-2 pattern recognition.
Collapse
Affiliation(s)
- Gábor Nagy
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Róza Földesi
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - István Csípő
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tünde Tarr
- Institute of Internal Medicine, Department of Clinical Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Gabriella Szűcs
- Institute of Internal Medicine, Department of Rheumatology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Antónia Szántó
- Institute of Internal Medicine, Department of Clinical Immunology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tamás Bubán
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Zoltán Szekanecz
- Institute of Internal Medicine, Department of Rheumatology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Mária Papp
- Department of Gastroenterology, Faculty of Medicine, University of Debrecen, Debrecen, Hungary; European Reference Network on Hepatological Diseases, ERN RARE-LIVER, Debrecen, Hungary
| | - János Kappelmayer
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Péter Antal-Szalmás
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.
| |
Collapse
|
2
|
Cinquanta L, Bizzaro N, Pesce G. Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems. Front Immunol 2021; 12:638863. [PMID: 33717188 PMCID: PMC7947926 DOI: 10.3389/fimmu.2021.638863] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 01/18/2021] [Indexed: 12/11/2022] Open
Abstract
The recent availability of automated computer-assisted diagnosis (CAD) systems for the reading and interpretation of the anti-nuclear antibody (ANA) test performed with the indirect immunofluorescence (IIF) method on HEp-2 cells, has improved the reproducibility of the results and initiated a process of harmonization of this test. Furthermore, CAD systems provide quantitative expression of fluorescence intensity, allowing the introduction of objective quality control procedures to the monitoring of the entire process. The calibration of the reading systems and the automated image interpretation are essential prerequisites for obtaining reproducible and harmonized IIF test results and form the basis for standardization, regardless of the computer algorithms used in the different systems. The use of automated CAD systems, facilitating control procedures, represents a step forward for the quality certification of the laboratory.
Collapse
Affiliation(s)
- Luigi Cinquanta
- Laboratorio di Patologia Clinica, IRCCS S.D.N., Napoli, Italy
| | - Nicola Bizzaro
- Laboratorio di Patologia Clinica, Ospedale San Antonio, Tolmezzo—Azienda Sanitaria Universitaria Integrata di Udine, Udine, Italy
| | - Giampaola Pesce
- Laboratorio Diagnostico di Autoimmunologia, IRCCS Ospedale Policlinico San Martino, Genova, Italy
- Dipartimento di Medicina Interna e Specialità Mediche (DIMI), Università Degli Studi di Genova, Genova, Italy
| |
Collapse
|