1
|
Nagaraj YK, Balushi SA, Robb C, Uppal N, Dutta S, Mukerji A. Peri-extubation settings in preterm neonates: a systematic review and meta-analysis. J Perinatol 2024; 44:257-265. [PMID: 38216677 DOI: 10.1038/s41372-024-01870-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 12/20/2023] [Accepted: 01/03/2024] [Indexed: 01/14/2024]
Abstract
OBJECTIVE To systematically review: 1) peri-extubation settings; and 2) association between peri-extubation settings and outcomes in preterm neonates. STUDY DESIGN In this systematic review, studies were eligible if they reported patient-data on peri-extubation settings (objective 1) and/or evaluated peri-extubation levels in relation to clinical outcomes (objective 2). Data were meta-analyzed when appropriate using random-effects model. RESULTS Of 9681 titles, 376 full-texts were reviewed and 101 included. The pooled means of peri-extubation settings were summarized. For objective 2, three experimental studies were identified comparing post-extubation CPAP levels. Meta-analyses revealed lower odds for treatment failure [pooled OR 0.46 (95% CI 0.27-0.76); 3 studies, 255 participants] but not for re-intubation [pooled OR 0.66 (0.22-1.97); 3 studies, 255 participants] with higher vs. lower CPAP. CONCLUSIONS Summary of peri-extubation settings may guide clinicians in their own practices. Higher CPAP levels may reduce extubation failure, but more data on peri-extubation settings that optimize outcomes are needed.
Collapse
Affiliation(s)
| | | | - Courtney Robb
- Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| | - Nikhil Uppal
- Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| | - Sourabh Dutta
- Department of Pediatrics, Postgraduate Institute of Medical Education and Research (PGIMER), Chandigarh, India
| | - Amit Mukerji
- Department of Pediatrics, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
2
|
Scholten AWJ, van Leuteren RW, de Waal CG, Kraaijenga JV, de Jongh FH, van Kaam AH, Hutten GJ. Diaphragmatic electromyography in infants: an overview of possible clinical applications. Pediatr Res 2024; 95:52-58. [PMID: 37660179 DOI: 10.1038/s41390-023-02800-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 07/19/2023] [Accepted: 08/09/2023] [Indexed: 09/04/2023]
Abstract
Preterm infants often experience breathing instability and a hampered lung function. Therefore, these infants receive cardiorespiratory monitoring and respiratory support. However, the current respiratory monitoring technique may be unreliable for especially obstructive apnea detection and classification and it does not provide insight in breathing effort. The latter makes the selection of the adequate mode and level of respiratory support difficult. Electromyography of the diaphragm (dEMG) has the potential of monitoring heart rate (HR) and respiratory rate (RR), and it provides additional information on breathing effort. This review summarizes the available evidence on the clinical potential of dEMG to provide cardiorespiratory monitoring, to synchronize patient-ventilator interaction, and to optimize the mode and level of respiratory support in the individual newborn infant. We also try to identify gaps in knowledge and future developments needed to ensure widespread implementation in clinical practice. IMPACT: Preterm infants require cardiorespiratory monitoring and respiratory support due to breathing instability and a hampered lung function. The current respiratory monitoring technique may provide unreliable measurements and does not provide insight in breathing effort, which makes the selection of the optimal respiratory support settings difficult. Measuring diaphragm activity could improve cardiorespiratory monitoring by providing insight in breathing effort and could potentially have an important role in individualizing respiratory support in newborn infants.
Collapse
Affiliation(s)
- Anouk W J Scholten
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands
| | - Ruud W van Leuteren
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands
| | - Cornelia G de Waal
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands
| | - Juliette V Kraaijenga
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands
| | - Frans H de Jongh
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Faculty of Science and Technology, University of Twente, Drienerlolaan 5, Enschede, the Netherlands
| | - Anton H van Kaam
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands
| | - Gerard J Hutten
- Department of Neonatology, Amsterdam UMC location University of Amsterdam, Meibergdreef 9, Amsterdam, the Netherlands.
- Amsterdam Reproduction & Development research institute, Amsterdam, the Netherlands.
| |
Collapse
|
3
|
Fu M, Hu Z, Yu G, Luo Y, Xiong X, Yang Q, Song W, Yu Y, Yang T. Predictors of extubation failure in newborns: a systematic review and meta-analysis. Ital J Pediatr 2023; 49:133. [PMID: 37784184 PMCID: PMC10546653 DOI: 10.1186/s13052-023-01538-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 09/21/2023] [Indexed: 10/04/2023] Open
Abstract
Extubation failure (EF) is a significant concern in mechanically ventilated newborns, and predicting its occurrence is an ongoing area of research. To investigate the predictors of EF in newborns undergoing planned extubation, we conducted a systematic review and meta-analysis. A systematic literature search was conducted in PubMed, Web of Science, Embase, and Cochrane Library for studies published in English from the inception of each database to March 2023. The PRISMA guidelines were followed in all phases of this systematic review. The Risk of Bias Assessment for Nonrandomized Studies tool was used to assess methodological quality. Thirty-four studies were included, 10 of which were overall low risk of bias, 15 of moderate risk of bias, and 9 of high risk of bias. The studies reported 43 possible predictors in six broad categories (intrinsic factors; maternal factors; diseases and adverse conditions of the newborn; treatment of the newborn; characteristics before and after extubation; and clinical scores and composite indicators). Through a qualitative synthesis of 43 predictors and a quantitative meta-analysis of 19 factors, we identified five definite factors, eight possible factors, and 22 unclear factors related to EF. Definite factors included gestational age, sepsis, pre-extubation pH, pre-extubation FiO2, and respiratory severity score. Possible factors included age at extubation, anemia, inotropic use, mean airway pressure, pre-extubation PCO2, mechanical ventilation duration, Apgar score, and spontaneous breathing trial. With only a few high-quality studies currently available, well-designed and more extensive prospective studies investigating the predictors affecting EF are still needed. In the future, it will be important to explore the possibility of combining multiple predictors or assessment tools to enhance the accuracy of predicting extubation outcomes in clinical practice.
Collapse
Affiliation(s)
- Maoling Fu
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Zhenjing Hu
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Genzhen Yu
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China.
| | - Ying Luo
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
| | - Xiaoju Xiong
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
| | - Qiaoyue Yang
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Wenshuai Song
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Yaqi Yu
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Ting Yang
- Department of Nursing, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Qiaokou District, 1095 Jiefang Road, Wuhan, Hubei Province, China
- School of Nursing, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| |
Collapse
|
4
|
Liu YC, Yeh CY, Yang ST, Chung WC, Hsu TJ, Sheu CC, Chen HL. Feasibility of Endotracheal Extubation Evaluation Form in Predicting Successful Extubation in Neonatal Intensive Care Units: A Retrospective Study. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1053. [PMID: 37371284 DOI: 10.3390/children10061053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 06/08/2023] [Accepted: 06/10/2023] [Indexed: 06/29/2023]
Abstract
Given the limited availability of evidence-based methods for assessing the timing of extubation in intubated preterm infants, we aimed to standardize the extubation protocol in this single-center, retrospective study. To accomplish this, we established an extubation evaluation form to assess the suitability of extubation in preterm infants. The form comprises six indicators: improved clinical condition, spontaneous breath rate ≥ 30 breaths per minute, peak inspiratory pressure (PIP) ≤ 15 cmH2O, fraction of inspired oxygen (FiO2) ≤ 30%, blood pH ≥ 7.2, and mixed venous carbon dioxide tension (PvCO2) < 70 mmHg. Each positive answer is given one point, indicating a maximum of six points. We enrolled 41 intubated preterm infants (gestational age < 32 weeks, birth weight < 1500 g) who were receiving mechanical ventilation support for over 24 h. Among them, 35 were successfully extubated, and 6 were not. After completing the extubation evaluation form and adjusting for birth weight and postextubation device, we observed that the total score of the form was significantly associated with successful extubation; the higher the score, the greater the chance of successful extubation. Thus, we infer that the extubation evaluation form may provide a more objective standard for extubation assessment in preterm infants.
Collapse
Affiliation(s)
- Yung-Cheng Liu
- Division of Respiratory Therapy, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Ching-Yi Yeh
- Division of Respiratory Therapy, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Shu-Ting Yang
- Department of Pediatrics, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Wei-Chan Chung
- Division of Respiratory Therapy, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Tuan-Jung Hsu
- Division of Respiratory Therapy, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
| | - Chau-Chyun Sheu
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
- Department of Internal Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan
| | - Hsiu-Lin Chen
- Department of Pediatrics, Kaohsiung Medical University Hospital, Kaohsiung 807, Taiwan
- Department of Respiratory Therapy, College of Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan
| |
Collapse
|
5
|
Validation of a non-invasive pressure-time index of the inspiratory muscles in spontaneously breathing newborn infants. J Clin Monit Comput 2023; 37:221-226. [PMID: 35674857 PMCID: PMC9852111 DOI: 10.1007/s10877-022-00882-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2022] [Accepted: 05/16/2022] [Indexed: 01/24/2023]
Abstract
To validate the pressure-time index of the inspiratory muscles as a non-invasive index of inspiratory muscle function in spontaneously breathing infants by comparing it against the gold-standard pressure-time index of the diaphragm. Prospective observational cohort study of consecutive infants breathing unsupported in room air in a tertiary neonatal intensive care unit, studied prior to discharge from neonatal care. The invasive pressure-time index of the diaphragm was calculated using a transdiaphragmatic dual-pressure catheter that measured transdiaphragmatic pressure by subtraction of the oesophageal from the gastric pressure. The non-invasive pressure-time index of the inspiratory muscles was calculated using pressure measurements at the level of the mouth via a differential pressure transducer connected to a face mask. Both indices were calculated as the product of the ratio of the mean inspiratory pressure divided by the maximum inspiratory pressure and the ratio of the inspiratory time divided by the total time of a respiratory cycle. One hundred and thirty infants (79 male) were included with a mean (SD) gestational age of 35.2 (3.2) weeks, studied at a median (IQR) postnatal age of 9 (6-20) days. The mean (SD) pressure-time index of the diaphragm was 0.063 (0.019) and the mean (SD) pressure-time index of the inspiratory muscles was 0.065 (0.023). The correlation coefficient for the two indices was 0.509 (p < 0.001). The mean (SD) absolute difference between the pressure-time index of the inspiratory muscles and pressure-time index of the diaphragm was 0.002 (0.021). In convalescent infants, the non-invasive pressure-time index of the inspiratory muscles had a moderate degree of correlation with the invasively derived pressure time index of the diaphragm measured with a transdiaphragmatic catheter.
Collapse
|
6
|
Dassios T, Vervenioti A, Dimitriou G. Respiratory muscle function in the newborn: a narrative review. Pediatr Res 2022; 91:795-803. [PMID: 33875805 PMCID: PMC8053897 DOI: 10.1038/s41390-021-01529-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 03/24/2021] [Accepted: 03/29/2021] [Indexed: 02/02/2023]
Abstract
Our aim was to summarise the current evidence and methods used to assess respiratory muscle function in the newborn, focusing on current and future potential clinical applications. The respiratory muscles undertake the work of breathing and consist mainly of the diaphragm, which in the newborn is prone to dysfunction due to lower muscle mass, flattened shape and decreased content of fatigue-resistant muscle fibres. Premature infants are prone to diaphragmatic dysfunction due to limited reserves and limited capacity to generate force and avoid fatigue. Methods to assess the respiratory muscles in the newborn include electromyography, maximal respiratory pressures, assessment for thoraco-abdominal asynchrony and composite indices, such as the pressure-time product and the tension time index. Recently, there has been significant interest and a growing body of research in assessing respiratory muscle function using bedside ultrasonography. Neurally adjusted ventilator assist is a novel ventilation mode, where the level of the respiratory support is determined by the diaphragmatic electrical activity. Prolonged mechanical ventilation, hypercapnia and hypoxia, congenital anomalies and systemic or respiratory infection can negatively impact respiratory muscle function in the newborn, while caffeine and synchronised or volume-targeted ventilation have a positive effect on respiratory muscle function compared to conventional, non-triggered or pressure-limited ventilation, respectively. IMPACT: Respiratory muscle function is impaired in prematurely born neonates and infants with congenital anomalies, such as congenital diaphragmatic hernia. Respiratory muscle function is negatively affected by prolonged ventilation and infection and positively affected by caffeine and synchronised compared to non-synchronised ventilation modes. Point-of-care diaphragmatic ultrasound and neurally adjusted ventilator assist are recent diagnostic and therapeutic technological developments with significant clinical applicability.
Collapse
Affiliation(s)
- Theodore Dassios
- Department of Women and Children's Health, King's College London, London, UK.
- Department of Paediatrics, University of Patras, Patras, Greece.
| | | | | |
Collapse
|
7
|
Diaphragmatic electromyography during a spontaneous breathing trial to predict extubation failure in preterm infants. Pediatr Res 2022; 92:1064-1069. [PMID: 35523885 PMCID: PMC9586868 DOI: 10.1038/s41390-022-02085-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 03/04/2022] [Accepted: 03/26/2022] [Indexed: 12/02/2022]
Abstract
BACKGROUND Premature attempts at extubation and prolonged episodes of ventilatory support in preterm infants have adverse outcomes. The aim of this study was to determine whether measuring the electrical activity of the diaphragm during a spontaneous breathing trial (SBT) could predict extubation failure in preterm infants. METHODS When infants were ready for extubation, the electrical activity of the diaphragm was measured by transcutaneous electromyography (EMG) before and during a SBT when the infants were on endotracheal continuous positive airway pressure. RESULTS Forty-eight infants were recruited (median (IQR) gestational age of 27.2 (25.6-30.4) weeks). Three infants did not pass the SBT and 13 failed extubation. The amplitude of the EMG increased during the SBT [2.3 (1.5-4.2) versus 3.5 (2.1-5.3) µV; p < 0.001]. In the whole cohort, postmenstrual age (PMA) was the strongest predictor for extubation failure (area under the curve (AUC) 0.77). In infants of gestational age <29 weeks, the percentage change of the EMG predicted extubation failure with an AUC of 0.74 while PMA was not associated with the outcome of extubation. CONCLUSIONS In all preterm infants, PMA was the strongest predictor of extubation failure; in those born <29 weeks of gestation, diaphragmatic electromyography during an SBT was the best predictor of extubation failure. IMPACT Composite assessments of readiness for extubation may be beneficial in the preterm population. Diaphragmatic electromyography measured by surface electrodes is a non-invasive technique to assess the electrical activity of the diaphragm. Postmenstrual age was the strongest predictor of extubation outcome in preterm infants. The change in diaphragmatic activity during a spontaneous breathing trial in extremely prematurely born infants can predict subsequent extubation failure with moderate sensitivity and specificity.
Collapse
|
8
|
Diaphragm Activity Pre and Post Extubation in Ventilated Critically Ill Infants and Children Measured With Transcutaneous Electromyography. Pediatr Crit Care Med 2021; 22:950-959. [PMID: 34534162 DOI: 10.1097/pcc.0000000000002828] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Swift extubation is important to prevent detrimental effects of invasive mechanical ventilation but carries the risk of extubation failure. Accurate tools to assess extubation readiness are lacking. This study aimed to describe the effect of extubation on diaphragm activity in ventilated infants and children. Our secondary aim was to compare diaphragm activity between failed and successfully extubated patients. DESIGN Prospective, observational study. SETTING Single-center tertiary neonatal ICU and PICU. PATIENTS Infants and children receiving invasive mechanical ventilation longer than 24 hours. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Diaphragm activity was measured with transcutaneous electromyography, from 15 minutes before extubation till 180 minutes thereafter. Peak and tonic activity, inspiratory amplitude, inspiratory area under the curve, and respiratory rate were calculated from the diaphragm activity waveform. One hundred forty-seven infants and children were included (median postnatal age, 1.9; interquartile range, 0.9-6.7 wk). Twenty patients (13.6%) failed extubation within 72 hours. Diaphragm activity increased rapidly after extubation and remained higher throughout the measurement period. Pre extubation, peak (end-inspiratory) diaphragm activity and tonic (end-inspiratory) diaphragm activity were significantly higher in failure, compared with success cases (5.6 vs 7.0 μV; p = 0.04 and 2.8 vs 4.1 μV; p = 0.04, respectively). Receiver operator curve analysis showed the highest area under the curve for tonic (end-inspiratory) diaphragm activity (0.65), with a tonic (end-inspiratory) diaphragm activity greater than 3.4 μV having a combined sensitivity and specificity of 55% and 77%, respectively, to predict extubation outcome. After extubation, diaphragm activity remained higher in patients failing extubation. CONCLUSIONS Diaphragm activity rapidly increased after extubation. Patients failing extubation had a higher level of diaphragm activity, both pre and post extubation. The predictive value of the diaphragm activity variables alone was limited. Future studies are warranted to assess the additional value of electromyography of the diaphragm in combined extubation readiness assessment.
Collapse
|