Simcox LE, Higgins LE, Myers JE, Johnstone ED. Intraexaminer and Interexaminer Variability in 3D Fetal Volume Measurements During the Second and Third Trimesters of Pregnancy. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1415-1429. [PMID: 28339117 DOI: 10.7863/ultra.16.03045] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2016] [Accepted: 09/22/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES To assess intraexaminer and interexaminer reliability of 3-dimensional fetal sonographic measurements. METHODS Three-dimensional fetal organ volumes (head, kidney, total thigh volume, and fractional thigh volume) were acquired during the second and third trimesters, with the addition of placental volume in the second trimester, by 2 different experienced, blinded sonographers. Fifty-eight fetuses were examined from 21 to 39 weeks' gestation. Intraexaminer and Interexaminer reliability was assessed with Bland-Altman plots, and their 95% limits of agreement and intraclass correlation coefficients. RESULTS The most significant interexaminer error was observed in the second-trimester kidney volume (95% limits of agreement, ± 110%), and the best agreement was for the third-trimester fractional thigh volume (95% limits of agreement, ± 25%) and second-trimester head volume (95% limits of agreement, -7%-25%). Second- and third-trimester intraclass correlation coefficient results were all greater than 0.75, apart from second-trimester kidney volume intraexaminer (0.374) and interexaminer (0.061) measurements, second-trimester placenta interexaminer measurements (0.390), and third-trimester kidney interexaminer measurements (0.647). CONCLUSIONS Three-dimensional fetal sonographic volumes of the head, kidney, total thigh, and placenta have limited reproducibility, and improvements in measurement techniques are needed before they can be used routinely to assess fetal growth. The 3-dimensional fractional thigh volume can be reliably obtained in the late third trimester.
Collapse
Affiliation(s)
- Louise E Simcox
- Maternal and Fetal Health Research Center, Institute of Human Development, University of Manchester, Manchester, England
- St Mary's Hospital, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Center, Manchester, England
| | - Lucy E Higgins
- Maternal and Fetal Health Research Center, Institute of Human Development, University of Manchester, Manchester, England
- St Mary's Hospital, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Center, Manchester, England
| | - Jenny E Myers
- Maternal and Fetal Health Research Center, Institute of Human Development, University of Manchester, Manchester, England
- St Mary's Hospital, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Center, Manchester, England
| | - Edward D Johnstone
- Maternal and Fetal Health Research Center, Institute of Human Development, University of Manchester, Manchester, England
- St Mary's Hospital, Central Manchester University Hospitals National Health Service Foundation Trust, Manchester Academic Health Science Center, Manchester, England
| |
Collapse
|
2
|
Barros CA, Rezende GDC, Araujo Júnior E, Tonni G, Pereira AK. Prediction of lethal pulmonary hypoplasia by means fetal lung volume in skeletal dysplasias: a three-dimensional ultrasound assessment. J Matern Fetal Neonatal Med 2015; 29:1725-30. [PMID: 26135769 DOI: 10.3109/14767058.2015.1064887] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE The aim of this study was to assess the capacity of three-dimensional ultrasound (3DUS) for predicting lethality in fetuses with skeletal dysplasia. METHODS Twenty-four fetuses between 20 and 32 weeks of gestation were assessed. Bilateral lung volume scans were performed three times in each fetus during one ultrasound session. The virtual organ computer-aided analysis method was used to obtain a sequence of six sections of each lung around a fixed axis, and a rotation angle of 30° was adopted. Fetal lung volume measurements were analyzed according to the reference range. After birth, lung hypoplasia was diagnosed considering clinical and radiological criteria. RESULTS Of all cases of skeletal dysplasia, 18 (75%) were lethal. Among the lethal cases, after postnatal diagnosis, four were osteogenesis imperfecta type II, three were thanatophoric dysplasia and two were campomelic dysplasia. The remaining nine cases remained without a definitive diagnosis. The accuracy of 3DUS in predicting lethality in fetuses with skeletal dysplasia was high, with a sensitivity of 83.3%, specificity of 100%, positive predictive value of 100% and negative predictive value of 66.7%. The kappa index of 0.174 showed a good agreement between the possibility of lethality when the 3DUS volume measurement was altered and real lethality after birth (p < 0.001). CONCLUSION This study suggests that the 3DUS lung volume measurement is a good predictor of lethal pulmonary hypoplasia in fetuses with skeletal dysplasia, with high accuracy.
Collapse
Affiliation(s)
- Carolina Amorim Barros
- a Department of Obstetrics and Gynecology , Center of Fetal Medicine, Federal University of Minas Gerais (UFMG) , Belo Horizonte , MG , Brazil
| | - Guilherme de Castro Rezende
- a Department of Obstetrics and Gynecology , Center of Fetal Medicine, Federal University of Minas Gerais (UFMG) , Belo Horizonte , MG , Brazil
| | - Edward Araujo Júnior
- b Department of Obstetrics , Paulista School of Medicine - Federal University of São Paulo (EPM-UNIFESP) , São Paulo , SP , Brazil , and
| | - Gabriele Tonni
- c Department of Obstetrics and Gynecology , Prenatal Diagnostic Center, Guastalla Civil Hospital , Reggio Emilia , Italy
| | - Alamanda Kfoury Pereira
- a Department of Obstetrics and Gynecology , Center of Fetal Medicine, Federal University of Minas Gerais (UFMG) , Belo Horizonte , MG , Brazil
| |
Collapse
|
3
|
Coelho Neto MA, Roncato P, Nastri CO, Martins WP. True Reproducibility of UltraSound Techniques (TRUST): systematic review of reliability studies in obstetrics and gynecology. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2015; 46:14-20. [PMID: 25175693 DOI: 10.1002/uog.14654] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2014] [Revised: 08/15/2014] [Accepted: 08/22/2014] [Indexed: 06/03/2023]
Abstract
OBJECTIVES To examine the quality of methods used and the accuracy of the interpretation of agreement in existing studies that examine the reliability of ultrasound measurements and judgments in obstetrics and gynecology. METHODS A systematic search of MEDLINE was performed on 25 March 2014, looking for studies that examined the reliability of ultrasound measurements and judgments in obstetrics and gynecology with evaluation of concordance (CCC) or intraclass (ICC) correlation coefficients or kappa as a main objective. RESULTS Seven hundred and thirty-three records were examined on the basis of their title and abstract, of which 141 full-text articles were examined completely for eligibility. We excluded 29 studies because they did not report CCC/ICC/kappa, leaving 112 studies that were included in our analysis. Two studies reported both ICC and kappa and were counted twice, therefore, the number used as the denominator in the analyses was 114. Only 16/114 (14.0%) studies were considered to be well designed (independent acquisition and blinded analysis) and to have interpreted the results properly. Most errors occurring in the studies are likely to overestimate the reliability of the method examined. CONCLUSIONS The vast majority of published studies examined had important flaws in design, interpretation and/or reporting. Such limitations are important to identify as they might create false confidence in the existing measurements and judgments, jeopardizing clinical practice and future research. Specific guidelines aimed at improving the quality of reproducibility studies that examine ultrasound methods should be encouraged.
Collapse
Affiliation(s)
- M A Coelho Neto
- Department of Obstetrics and Gynecology, Ribeirao Preto Medical School, University of Sao Paulo (DGO-FMRP-USP), Ribeirao Preto, Brazil
| | - P Roncato
- Department of Obstetrics and Gynecology, Ribeirao Preto Medical School, University of Sao Paulo (DGO-FMRP-USP), Ribeirao Preto, Brazil
- School of Health Technology - Ultrasonography School of Ribeirao Preto (FATESA-EURP), Ribeirao Preto, Brazil
| | - C O Nastri
- Department of Obstetrics and Gynecology, Ribeirao Preto Medical School, University of Sao Paulo (DGO-FMRP-USP), Ribeirao Preto, Brazil
| | - W P Martins
- Department of Obstetrics and Gynecology, Ribeirao Preto Medical School, University of Sao Paulo (DGO-FMRP-USP), Ribeirao Preto, Brazil
| |
Collapse
|
4
|
Tonni G, Martins WP, Guimarães Filho H, Araujo Júnior E. Role of 3-D ultrasound in clinical obstetric practice: evolution over 20 years. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1180-1211. [PMID: 25748522 DOI: 10.1016/j.ultrasmedbio.2014.12.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2014] [Revised: 12/10/2014] [Accepted: 12/11/2014] [Indexed: 06/04/2023]
Abstract
The use of 3-D ultrasound in obstetrics has undergone dramatic development over the past 20 years. Since the first publications on this application in clinical practice, several 3-D ultrasound techniques and rendering modes have been proposed and applied to the study of fetal brain, face and cardiac anatomy. In addition, 3-D ultrasound has improved calculations of the volume of fetal organs and limbs and estimations of fetal birth weight. And furthermore, angiographic patterns of fetal organs and the placenta have been assessed using 3-D power Doppler ultrasound quantification. In this review, we aim to summarize current evidence on the clinical relevance of these methodologies and their application in obstetric practice.
Collapse
Affiliation(s)
- Gabriele Tonni
- Department of Obstetrics and Gynecology, Guastalla Civil Hospital, ASL Reggio Emilia, Italy; Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Wellington P Martins
- Department of Obstetrics and Gynecology, Ribeirão Preto School of Medicine, University of São Paulo (DGO-FMRP-USP), Ribeirão Preto-SP, Brazil
| | | | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil.
| |
Collapse
|
5
|
Nardozza LMM, Passos AP, Araujo Júnior E, Bruns RF, Moron AF. Reference intervals of fetal cisterna magna volume by two-dimensional method using the multiplanar mode of three-dimensional ultrasonography. Radiol Bras 2015; 47:201-5. [PMID: 25741085 PMCID: PMC4337116 DOI: 10.1590/0100-3984.2013.1852] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Accepted: 02/20/2014] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE To establish reference intervals for the fetal cisterna magna volume by means of two-dimensional (2D) method using the multiplanar mode of three-dimensional ultrasonography. MATERIALS AND METHODS Cross-sectional study with 224 healthy pregnant women between the 17th and 29th gestational weeks. The volume was automatically obtained by multiplying the three major axes in axial and sagittal planes by the constant 0.52. Polynomial regression was utilized to establish the correlation between fetal cisterna magna volume and gestational age, with adjustments by coefficient of determination (R(2)). Reliability and agreement were obtained by intraclass correlation coefficient (ICC) and limits of agreement, respectively. RESULTS Mean fetal cisterna volume with the 2D method ranged from 0.71 ± 0.19 cm(3) to 4.18 ± 0.75 cm(3) at the 17th and 29th weeks, respectively. The authors observed a good correlation between fetal cisterna magna volume and gestational age (R(2) = 0.67), excellent intraobserver reliability and agreement with ICC = 0.89 and limits of agreement 95% (-52.0; 51.8), respectively, and low interobserver reliability and agreement with ICC = 0.64 and limits of agreement 95% (-110.1; 84.6), respectively. CONCLUSION Reference intervals for fetal cisterna magna volume by means of 2D method using the multiplanar mode of three-dimensional ultrasonography were established and presented excellent intraobserver reliability and agreement.
Collapse
Affiliation(s)
- Luciano Marcondes Machado Nardozza
- Private Docents, Associate Professors, Obstetrics Department, Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Ana Paula Passos
- Master, Physician Assistant at Clínica Fetalmed, Curitiba, PR, Brazil
| | - Edward Araujo Júnior
- Private Docents, Associate Professors, Obstetrics Department, Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| | - Rafael Frederico Bruns
- PhD, Associate Professor, Gynecology and Obstetrics Department, Universidade Federal do Paraná (UFPR), Curitiba, PR, Brazil
| | - Antonio Fernandes Moron
- Private Docent, Full Professor, Obstetrics Department, Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-Unifesp), São Paulo, SP, Brazil
| |
Collapse
|
6
|
Kehl S, Kalk AL, Eckert S, Schaible T, Sütterlin M, Neff W, Siemer J. Assessment of lung volume by 3-dimensional sonography and magnetic resonance imaging in fetuses with congenital diaphragmatic hernias. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:1539-1545. [PMID: 22039026 DOI: 10.7863/jum.2011.30.11.1539] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVES The purpose of this study was to evaluate the influence of different rotation angles in assessment of the contralateral lung volume by 3-dimensional (3D) sonography in comparison to magnetic resonance imaging (MRI) in fetuses with congenital diaphragmatic hernias. METHODS A total of 126 measurements by 3D sonography and MRI were conducted in 81 patients between 18 and 39 weeks' gestation. The 3D sonographic volumes of the contralateral fetal lung were calculated by the rotational technique (virtual organ computer-aided analysis) with rotation angles of 6°, 15°, and 30°. Transverse multiplanar T2-weighted MRI was performed for the MRI measurements. To compare the accuracy of 3D sonographic volumetry using different rotation angles, MRI assessment was taken as the reference method, and percentage errors and limits of agreement were calculated for each angle. RESULTS Three-dimensional sonographic volume measurements showed a high correlation with MRI (6° angle, R(2) = 0.86; 15° angle, R(2) = 0.78; 30° angle, R(2) = 0.68). The mean percentage error showed no systematic error. With regard to random error, the 6° step had significantly lower values than the larger angles 30° step (R = 0.472) and the narrowest limits of agreement. CONCLUSIONS Especially when using a small rotation angle, assessment of the contralateral fetal lung volume by 3D sonography in congenital diaphragmatic hernias is a reliable alternative to MRI.
Collapse
Affiliation(s)
- Sven Kehl
- Departments of Obstetrics and Gynecology, Mannheim University Medical Center, Heidelberg University, Mannheim, Germany.
| | | | | | | | | | | | | |
Collapse
|
7
|
Kehl S, Eckert S, Sütterlin M, Neff KW, Siemer J. Influence of different rotation angles in assessment of lung volumes by 3-dimensional sonography in comparison to magnetic resonance imaging in healthy fetuses. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2011; 30:819-825. [PMID: 21632997 DOI: 10.7863/jum.2011.30.6.819] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
OBJECTIVES Three-dimensional (3D) sonographic volumetry is established in gynecology and obstetrics. Assessment of the fetal lung volume by magnetic resonance imaging (MRI) in congenital diaphragmatic hernias has become a routine examination. In vitro studies have shown a good correlation between 3D sonographic measurements and MRI. The aim of this study was to compare the lung volumes of healthy fetuses assessed by 3D sonography to MRI measurements and to investigate the impact of different rotation angles. METHODS A total of 126 fetuses between 20 and 40 weeks' gestation were measured by 3D sonography, and 27 of them were also assessed by MRI. The sonographic volumes were calculated by the rotational technique (virtual organ computer-aided analysis) with rotation angles of 6° and 30°. To evaluate the accuracy of 3D sonographic volumetry, percentage error and absolute percentage error values were calculated using MRI volumes as reference points. Formulas to calculate total, right, and left fetal lung volumes according to gestational age and biometric parameters were derived by stepwise regression analysis. RESULTS Three-dimensional sonographic volumetry showed a high correlation compared to MRI (6° angle, R(2) = 0.971; 30° angle, R(2) = 0.917) with no systematic error for the 6° angle. Moreover, using the 6° rotation angle, the median absolute percentage error was significantly lower compared to the 30° angle (P < .001). The new formulas to calculate total lung volume in healthy fetuses only included gestational age and no biometric parameters (R(2) = 0.853). CONCLUSIONS Three-dimensional sonographic volumetry of lung volumes in healthy fetuses showed a good correlation with MRI. We recommend using an angle of 6° because it assessed the lung volume more accurately. The specifically designed equations help estimate lung volumes in healthy fetuses.
Collapse
Affiliation(s)
- Sven Kehl
- Department of Obstetrics and Gynecology, Mannheim University Hospital, Mannheim, Germany.
| | | | | | | | | |
Collapse
|
8
|
Simioni C, Nardozza LMM, Araujo Júnior E, Rolo LC, Zamith M, Caetano AC, Moron AF. Heart stroke volume, cardiac output, and ejection fraction in 265 normal fetus in the second half of gestation assessed by 4D ultrasound using spatio-temporal image correlation. J Matern Fetal Neonatal Med 2011; 24:1159-67. [PMID: 21250911 DOI: 10.3109/14767058.2010.545921] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVES The aim of this study was to establish nomograms for fetal stroke volume (SV), cardiac output (CO), and ejection fraction (EF) using four-dimensional ultrasound with spatio-temporal image correlation (STIC) modality. METHODS The fetal heart was scanned using STIC modality, starting with classic four-chamber view plane, during fetal quiescence with abdomen uppermost, at an angle of 20-30°, without color Doppler flow mapping. In post-processing virtual organ, computer-aided analysis technique was used to obtain a sequence of six sections of each ventricular volume in end-systolic volume (ESV) and end-diastolic volume (EDV). The SV (SV = EDV-ESV), CO (CO = SV × fetal heart rate), and EF (EF = SV/EDV) for each ventricle were then calculated. Intra- and interobserver agreement were then calculated. RESULTS Two hundred sixty-five fetuses, ranging in gestational age (GA) from 20 to 34(+6) weeks, were included in the study. The left and right SV and CO increased exponentially with gestation and EF remained fairly stable through gestational. Mean left and right SV increased from 0.211 ml and 0.220 ml at 20 weeks to 1.925 ml and 2.043 ml, respectively, at 34 weeks. Mean left and right CO increased from 30.25 ml/min and 31.52 ml/min at 20 weeks to 268.49 ml/min and 287.80 ml/min, respectively, at 34 weeks. Both left and right mean EF remained constant at around 0.63 with advancing GA. Nomograms were created for LSV, RSV, LCO, RCO, LEF, and REF vs. gestational age. Intra- and interobserver agreement reached 95%. CONCLUSIONS Four-dimensional ultrasound using STIC represents a simple and reproducible method for estimating fetal cardiac function. STIC seems to overcome many of the pitfalls of conventional ultrasound methods and has the potential to become the method of choice.
Collapse
Affiliation(s)
- Christiane Simioni
- Department of Obstetrics, São Paulo Federal University (UNIFESP), São Paulo, Brazil
| | | | | | | | | | | | | |
Collapse
|
9
|
Fetal cardiac function assessed by spatio-temporal image correlation. Arch Gynecol Obstet 2010; 284:253-60. [PMID: 21188403 DOI: 10.1007/s00404-010-1813-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2010] [Accepted: 12/08/2010] [Indexed: 02/06/2023]
Abstract
BACKGROUND Three-dimensional (3D) and four-dimensional (4D) ultrasound have been proposed to be valuable tools for the examination of fetal heart. Spatio-temporal image correlation (STIC) is a technique that adds a time component to 3D ultrasound imaging of the fetal heart, so we can evaluate cardiac structures as a 4D cine sequence containing information of one full cardiac cycle. STIC gives the investigator the opportunity to freeze the displayed cardiac loop in end-diastolic and end-systolic phases. By STIC, 3D measurements of both the left and right ventricle can be used to calculate fetal heart stroke volume, cardiac output and ejection fraction, and expressions of cardiac function. The ultimate goal of STIC technique is to improve fetal cardiac function analysis by decreasing the dependency on operator skills required by two-dimensional ultrasound. CONTEXT In this article, we describe literature practical approach for the examination of the fetal heart function using 4D ultrasound by STIC technique.
Collapse
|
10
|
Araujo Júnior E, De Oliveira PS, Nardozza LMM, Simioni C, Rolo LC, Goldman SM, Szejnfeld J, Moron AF. Fetal lung volume in fetuses with urinary tract malformations: comparison by 2D-, 3D-sonography and magnetic resonance imaging. J Matern Fetal Neonatal Med 2010; 23:60-8. [PMID: 19626568 DOI: 10.3109/14767050903121415] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To evaluate the concordance between two-dimensional ultrasonography (2DUS), three-dimensional ultrasonography (3DUS) and magnetic resonance imaging (MRI) in the assessment of lung volume in fetuses with urinary tract malformations (UTM). METHODS This was a cross-sectional study involving 12 pregnancies between 19 and 34 weeks, with various fetal UTM. Pulmonary volume was obtained by 2DUS using the following equation: total lung volume = [right lung antero-posterior diameter (X) x transverse diameter (Y) x cranial-caudal diameter x 0.152 + left lung (X1) x (Y1) x (Z1) x 0.167]. Pulmonary volume by 3DUS was obtained using the virtual organ computer-aided analysis (VOCAL) method with a 30 degrees (VOL30), 18 degrees (VOL18) and 12 degrees (VOL12) rotation. A fast sequence of transverse lung section was also obtained by MRI. The intraclass correlation coefficient was used to evaluate the correlation between the three methods. The paired student t-test was used to compare the means. RESULTS There was a strong correlation between the three methods, and the highest correlations were between MRI and VOL18 for the right (ICC = 0.913) and left (ICC = 0.947) lungs. A strong correlation was also found between the lung volumes obtained through MRI and VOL12 as well as VOL18 (p = 0.544 and 0.286, respectively). However, for the left lung there was only a correlation between MRI and VOL12 (p = 0.49). CONCLUSIONS There is a good concordance between 3DUS (VOL12) and MRI in the evaluation of lung volume in fetuses with UTM.
Collapse
Affiliation(s)
- Edward Araujo Júnior
- Obstetrics Department of São Paulo Federal University (UNIFESP), São Paulo, São Paulo, Brazil.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Werneck Britto IS, de Silva Bussamra LC, Araujo Júnior E, Tedesco GD, Nardozza LMM, Moron AF, Aoki T. Reference range of fetal lung volume by 3D-ultrasonography using the rotational method (VOCAL). J Perinat Med 2009; 37:161-7. [PMID: 18999915 DOI: 10.1515/jpm.2009.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AIM To determine reference ranges for fetal lung volume by 3-dimensional ultrasonography using the VOCAL (Virtual Organ Computed-aided Analysis) method. METHODS A longitudinal prospective study was conducted with 61 uncomplicated pregnancies between 24 and 32 weeks of gestation. A separate measurement of both lungs volume was conducted by VOCAL with 30 degrees rotation angle. For each gestational age, an average, standard deviation and maximal and minimal values were established in addition to the percentiles 5, 10, 25, 50, 75 and 90 for right and left lung volume. To evaluate the correlation between lung volume and gestational age, and estimated fetal weight, a polynomial regression with determination coefficient adjustment (R(2)) was used. The intra-observer reproducibility was evaluated by the intraclass correlation coefficient (ICC), whereas the inter-observer reproducibility was evaluated by Cronbach alpha statistic test. RESULTS The average right lung volume varied from 12.5+/-0.7 cm(3) at the 24(th) week to 31.8 cm(3)+/-1.8 cm(3) at the 32(nd) week. The average left lung volume varied from 9.2+/-0.9 cm(3) at the 24(th) week to 22.0 cm(3)+/-1.6 cm(3) at the 32(nd) week. We observed a strong correlation between right lung volume and gestational age (R(2)=0.975) and estimated fetal weight (R(2)=0.905), as well as between the left lung volume with gestational age (R(2)=0.970) and estimated fetal weight (R(2)=0.908). We observed a good intra-observer reproducibility for the right lung volume (ICC=0.990) and for the left lung volume (ICC=0.986). Similarly, we observed good inter-observer reproducibility for right lung volume (0.975) and left lung volume (0.962). CONCLUSION Reference range of fetal lung volume by 3D-ultrasonography using the VOCAL method was determined.
Collapse
Affiliation(s)
- Ingrid Schwach Werneck Britto
- Department of Gynecology and Obstetrics, Medical Science College of Santa Casa of São Paulo (FCMSCSP), São Paulo, SP, Brazil
| | | | | | | | | | | | | |
Collapse
|
12
|
Britto ISW, de Silva Bussamra LC, Araujo Júnior E, Tedesco GD, Nardozza LMM, Moron AF, Aoki T. Fetal lung volume: comparison by 2D- and 3D-sonography in normal fetuses. Arch Gynecol Obstet 2009; 280:363-8. [PMID: 19132381 DOI: 10.1007/s00404-008-0908-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2008] [Accepted: 12/19/2008] [Indexed: 11/30/2022]
Affiliation(s)
- Ingrid Schwach Werneck Britto
- Department of Gynecology and Obstetrics, Medical Science College of Santa Casa of São Paulo (FCMSCSP), São Paulo, SP, Brazil
| | | | | | | | | | | | | |
Collapse
|