1
|
Abou Hussein EM, Gafar SM. Effect of gamma rays on Zn/Cu doped strontium borate glass system for dosimetric applications. RADIOCHIM ACTA 2022. [DOI: 10.1515/ract-2022-0029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Two alkali strontium borate glasses containing Cu2+ or Zn2+ ions (0.15 mol%) has been prepared by melting annealing method. Some of the glasses dosimetric measurements have been performed; they were checked by ultraviolet-visible light measurement showing the specific peaks of Cu+/Cu2+ and Zn2+ ions. Upon γ-rays, glasses are sensitive to the absorbed dose in the range 0.4–15 kGy, revealing their light absorption. A gradual decrease in optical absorbance and DC electrical conductivity was detected with progressive irradiation. While a gradual increase in optical energy bandgap (Eopt) and electron paramagnetic resonance (EPR) was observed. The presence of transition metal ion (TM) with their variable configurations helps to trap the radiolytic electrons or holes during the color center recovery rates. UV–Vis and EPR dosimetric characteristics have high color stability with excellent short and long-term stability revealing their possible use as glass dosimeters in medical sterilization and food irradiation processing.
Collapse
Affiliation(s)
- Eman M. Abou Hussein
- Radiation Chemistry Department , National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority (EAEA) , Cairo , Egypt
| | - Sameh M. Gafar
- Radiation Protection and Dosimetry Department , National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority (EAEA) , Cairo , Egypt
| |
Collapse
|
2
|
Variation in dose response of three dosimetry systems based on diphenyl thiocarbazone. J Radioanal Nucl Chem 2022. [DOI: 10.1007/s10967-022-08392-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
AbstractThree different dosimetry systems were prepared based on diphenyl thiocarbazone (DTH) dye: polymer films made with, poly(vinyl alcohol), DTH liquid dosimeter and DTH gel dosimeter. All the systems received several gamma doses. The three systems were analyzing by UV–Vis spectrophotometery before and after irradiation. The effective dose range in the linear part of these systems is between 1–10 kGy, 0.3–2 kGy, and 50–200 Gy. The dose range of these three dosimeters relies on the concentration of DTH. The radiation chemical yield (G-value) was determined for the three prepared dosimeters, and all three radiation dosimeters were examined before and after irradiation.
Collapse
|
3
|
Abd El-Kader NM, Gafar SM. Effect of gamma radiation on a natural pigment and its possible use as a label dosimeter. J Radioanal Nucl Chem 2022. [DOI: 10.1007/s10967-021-08120-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|