1
|
Celik-Buyuktepe T, Ucakhan OO. Comparative Evaluation of Anterior Segment Optical Coherence Tomography Findings Following Accelerated Corneal Crosslinking Protocols Using Different Riboflavin Formulations and Soaking Durations. Curr Eye Res 2024:1-9. [PMID: 39090846 DOI: 10.1080/02713683.2024.2385441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 07/11/2024] [Accepted: 07/22/2024] [Indexed: 08/04/2024]
Abstract
PURPOSE To comparatively evaluate the influence of different riboflavin formulations and soaking durations on the anterior segment optical coherence tomography (AS-OCT) findings following accelerated corneal crosslinking (ACXL) at 9 mW/cm2 for in progressive keratoconus. METHODS In this prospective study, consecutive patients with progressive keratoconus were randomized into 4 groups. Group 1: hydroxypropyl methylcellulose (HPMC)-based riboflavin for 10 min; Group 2: HPMC-based riboflavin for 20 min; Group 3: dextran-based riboflavin (0.1%) for 30 min. Riboflavin soaking was followed by ultraviolet-A irradiation at 9 mW/cm2 for 10 min in all three groups. Group 4 underwent conventional CXL (CCXL) using Dresden protocol. The AS-OCT features of the crosslinked cornea were evaluated at postoperative month 1 and correlated to the clinical outcomes at postoperative month 12. RESULTS The study enrolled 26 eyes of 26 patients in each group. In groups 1 and 2, the AS-OCT findings were similar (p > .05) and the demarcation lines depth (DLD) were deep as obtained following CCXL. The DLD was significantly shallower in group 3 compared to the other groups (p < .01). There were no between-group differences in regards to the visual, refractive, keratometric, and tomographic outcomes at postoperative month 12. No significant endothelial cell loss or any other clinically significant adverse event was encountered in any patient's eye at 12 months follow-up. CONCLUSION Although structural variations were noted in the crosslinked cornea, DLDs observed following ACXL (9 mW/cm2) using HPMC-based solution for 10 or 20 min were similar to those observed following CCXL. Whereas, ACXL (9 mW/cm2) using dextran-based solution for 30 min resulted in the shallowest DLD. Despite these remodeling differences, the visual, refractive and tomographic outcomes of all groups were comparable at postoperative 1-year follow-up. Studies with a greater number of patients and longer follow-ups are required to establish any relation between AS-OCT characteristics of crosslinked cornea and ACXL efficacy.
Collapse
Affiliation(s)
| | - Omur O Ucakhan
- Department of Ophthalmology, Ankara University School of Medicine, Ankara, Turkey
| |
Collapse
|
2
|
Sachdev GS, Thulasidas M, Sachdev MS. Long-term outcomes of tailored stromal expansion with refractive lenticule for crosslinking thin corneas. Indian J Ophthalmol 2024; 72:94-97. [PMID: 38131577 PMCID: PMC10841800 DOI: 10.4103/ijo.ijo_762_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 09/19/2023] [Accepted: 10/07/2023] [Indexed: 12/23/2023] Open
Abstract
PURPOSE To assess the long-term safety and stability of visual outcomes following the modified technique of collagen crosslinking (CXL) using refractive lenticule in eyes with thin corneas (<400 µm) and progressive keratoconus. SETTING A tertiary eye care hospital in India. DESIGN Prospective, interventional case series. METHODS Eyes with progressive keratoconus and thin corneas (<400 µm) underwent CXL with intraoperative stromal augmentation using a refractive lenticule obtained from small-incision lenticule extraction (SMILE). Preoperative and postoperative evaluation (3 months, and then yearly thereafter) included corneal tomography (Oculus Pentacam), uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), manifest refraction, and endothelial cell count (specular microscopy), and adverse events, if any, were noted. The patients were followed up for a period of 5 years. RESULTS Seven eyes were included in the analysis. Mean corneal flattening of -4.29 D was noted from preoperative maximum keratometry (P = 0.018). An improvement in UDVA and CDVA of 0.38 logarithm of minimum angle of resolution (logMAR) and 0.36 logMAR, respectively, was noted at 5 years postoperative visit. Four eyes demonstrated a gain of two lines in CDVA. Mean spherical equivalent improved from -6.85 D preoperatively to -6.05 D at 5 years postoperatively. Clear demarcation line was noted between 230 to 270 µm on anterior segment optical coherence topography. No significant endothelial cell loss was noted postoperatively. CONCLUSION Long-term outcomes demonstrated safety and disease stability following lenticule-assisted CXL.
Collapse
Affiliation(s)
- Gitansha S Sachdev
- Cornea and Refractive Services, The Eye Foundation, Coimbatore, Tamil Nadu, India
| | | | | |
Collapse
|
3
|
Xanthopoulou K, Milioti G, Daas L, Munteanu C, Seitz B, Flockerzi E. Accelerated corneal crosslinking causes pseudoprogression in keratoconus within the first 6 weeks without affecting posterior corneal curvature. Eur J Ophthalmol 2022; 32:2565-2576. [PMID: 35535408 DOI: 10.1177/11206721221099257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate the effectiveness of epithelium-off (epi-off) accelerated corneal crosslinking (A-CXL, 9 mW/cm2, 10 min) in adult keratoconus (KC) patients. METHODS The study included 151 KC corneas (124 patients) after A-CXL. The parameters best corrected visual acuity (BCVA) and the tomographic readings (Pentacam HR, Oculus, Germany) were analysed at 24, 12 and 6 months preoperatively, prior to surgery; and 6 weeks, 6 months, 1, 2 and >2 years postoperatively. The demarcation line was assessed by anterior segment optical coherence tomography (Tomey SS-1000, CASIA 2 (Tomey, Nagoya, Japan)). RESULTS Comparing pre- to postoperative findings 6 weeks after A-CXL with paired t-test, the anterior steep (46.8 ± 4.0|47.1 ± 4.1), flat (50.2 ± 4.3|50.6 ± 4.6) and maximal keratometry (57.6 ± 6.8|58.3 ± 6.8) increased (p < 0.05), while the thinnest pachymetry decreased significantly (459 ± 39|444 ± 42, p < 0.05). Lateron, however, there was a decreasing anterior flat (1, 2 and >2 years; p < 0.0001), mean (1 year; p = 0.01 and 2 years; p = 0.03) and maximal keratometry (1, 2 and >2 years; p < 0.0001). The posterior corneal keratometry readings did not change significantly until >2 years after A-CXL (MANOVA; steep, p = 0.008; flat, p = 0.027; mean, p = 0.007). The mean depth of the demarcation line was 242 ± 62 µm (53.6%). The preoperative logMAR BCVA (0.35 ± 0.02) decreased 6 weeks after A-CXL (0.39 ± 0.03) followed by a continuous improvement until the latest follow-up (0.18 ± 0.04). CONCLUSION A-CXL constitutes a successful method for KC stabilization. Signs of KC progression occur within the first 6 weeks postoperatively ("pseudoprogression"), but this is not indicative of the long-term effect.
Collapse
Affiliation(s)
| | - Georgia Milioti
- Department of Ophthalmology, 39072Saarland University Medical Center, Homburg, Germany
| | - Loay Daas
- Department of Ophthalmology, 39072Saarland University Medical Center, Homburg, Germany
| | - Cristian Munteanu
- Department of Ophthalmology, 39072Saarland University Medical Center, Homburg, Germany
| | - Berthold Seitz
- Department of Ophthalmology, 39072Saarland University Medical Center, Homburg, Germany
| | - Elias Flockerzi
- Department of Ophthalmology, 39072Saarland University Medical Center, Homburg, Germany
| |
Collapse
|
4
|
Nicula CA, Rednik AM, Nicula AP, Bulboaca AE, Nicula D, Horvath KU. Comparative Results Between "Epi-Off" Accelerated and "Epi-Off" Standard Corneal Collagen Crosslinking-UVA in Progressive Keratoconus - 7 Years of Follow-Up. Ther Clin Risk Manag 2021; 17:975-988. [PMID: 34522101 PMCID: PMC8434931 DOI: 10.2147/tcrm.s321410] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Accepted: 08/14/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of the present study was to assess the long-term efficiency and safety of the “epi-off” accelerated CXL (9 mW/cm2 for 10 minutes) in comparison to the standard “epi-off” CXL (3 mW/cm2 for 30 minutes) in terms of topographical and keratometric parameters, refractive data and visual outcomes at 7 years of follow-up, in progressive keratoconus. Material and Method A retrospective and comparative study was performed. A total of 183 eyes from 183 patients with documented progressive keratoconus were included in the study. The patients were divided in two groups: 93 eyes from 93 patients underwent “epi-off” standard cross-linking technique (3 mW/cm2 for 30 minutes) (S-CXL group) and 90 eyes from 90 patients underwent accelerated “epi-off” corneal CXL technique (9 mW/cm2 for 10 minutes) (A-CXL group). Results Improvements in uncorrected distance visual acuity (UDVA) were statistically significant compared to baseline values in both groups at each time-point visit (p=0.0421 at 1 year, p=0.0411 at 7 years for A-CXL and p=0.0375 at 1 year, p=0.0389 at 7 years for S-CXL). At 7 years there was a statistically significant increase in CDVA (p=0.039 in the A-CXL group and p=0.0343 in the S-CXL group at 7 years). Statistically significant reduction was noticed in Ksteep (p=0.0411 in A-CXL group and p=0.0224 in S-CXL group), Kflat (p=0.0198 in A-CXL group and p=0.008 in S-CXL group), K mean (p=0.0106 in A-CXL group and p=0.0193 in S-CXL group) and Kmax (p=0.0413 in A-CXL group and p=0.054 in S-CXL group) at 7 years, compared to baseline values, in both groups, but without any statistically difference between the two procedures, at all time-point visits (p>0.05). Conclusion The long-term outcomes of “epi-off” accelerated corneal collagen crosslinking-UVA (9 mW/cm2 for 10 minutes) are similar to standard “epi-off” corneal collagen crosslinking procedure in the treatment of progressive keratoconus.
Collapse
Affiliation(s)
- Cristina Ariadna Nicula
- Department of Ophthalmology, Medicine and Pharmacy University "Iuliu Hațieganu", Cluj-Napoca, Romania.,Oculens Clinic, Cluj-Napoca, Romania
| | - Anca Maria Rednik
- Eye County Hospital, Department of Ophthalmology, Cluj-Napoca, Romania
| | | | - Adriana Elena Bulboaca
- Department of Pathophysiology, Medicine and Pharmacy University "Iuliu Hațieganu", Cluj Napoca, Romania
| | | | - Karin Ursula Horvath
- Department of Ophthalmology, Medicine and Pharmacy Science and Technology University "George Emil Palade", Târgu Mureș, Romania
| |
Collapse
|
5
|
Mazzotta C, Ferrise M, Gabriele G, Gennaro P, Meduri A. Chemically-Boosted Corneal Cross-Linking for the Treatment of Keratoconus through a Riboflavin 0.25% Optimized Solution with High Superoxide Anion Release. J Clin Med 2021; 10:jcm10061324. [PMID: 33806928 PMCID: PMC8004796 DOI: 10.3390/jcm10061324] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 03/13/2021] [Accepted: 03/18/2021] [Indexed: 11/28/2022] Open
Abstract
The purpose of this study was to evaluate the effectiveness and safety of a novel buffered riboflavin solution approved for corneal cross-linking (CXL) in progressive keratoconus and secondary corneal ectasia. Following the in vivo preclinical study performed on New Zealand rabbits comparing the novel 0.25% riboflavin solution (Safecross®) containing 1% hydroxypropyl methylcellulose (HPMC) with a 0.1% riboflavin solution containing 0.10% EDTA, accelerated epithelium-off CXL was performed on 10 patients (10 eyes treated, with the contralateral eye used as control) through UV-A at a power setting of 9 mW/cm2 with a total dose of 5.4 J/cm2. Re-epithelialization was evaluated in the postoperative 7 days by fluorescein dye test at biomicroscopy; endothelial cell count and morphology (ECD) were analyzed by specular microscopy at the 1st and 6th month of follow-up and demarcation line depth (DLD) measured by anterior segment optical coherence tomography (AS-OCT) one month after the treatment. We observed complete re-epithelization in all eyes between 72 and 96 h after surgery (88 h on average). ECD and morphology remained unchanged in all eyes. DLD was detected at a mean depth of 362 ± 50 µm, 20% over solutions with equivalent dosage. SafeCross® riboflavin solution chemically-boosted corneal cross-linking seems to optimize CXL oxidative reaction by higher superoxide anion release, improving DLD by a factor of 20%, without adverse events for corneal endothelium.
Collapse
Affiliation(s)
- Cosimo Mazzotta
- Departmental Ophthalmology Unit and USL Toscana Sud-Est, 53100 Siena, Italy;
- Post Graduate Ophthalmology School, Siena University, 53100 Siena, Italy
- Siena Crosslinking Center, Via Sandro Pertini 7, 53100 Siena, Italy
| | - Marco Ferrise
- Siena Crosslinking Center, Via Sandro Pertini 7, 53100 Siena, Italy
- Studio Oculistico Ferrise, 88046 Lamezia Terme, Italy
- Correspondence:
| | - Guido Gabriele
- Department of Oral and Maxillofacial Surgery, “Le Scotte” Hospital, Viale M. Bracci, 53100 Siena, Italy; (G.G.); (P.G.)
| | - Paolo Gennaro
- Department of Oral and Maxillofacial Surgery, “Le Scotte” Hospital, Viale M. Bracci, 53100 Siena, Italy; (G.G.); (P.G.)
| | - Alessandro Meduri
- Unit of Ophthalmology, Department of Biomedical Sciences, Dentistry, Morphological and Functional Imaging, University of Messina, 98100 Messina, Italy;
| |
Collapse
|
6
|
Rapuano PB, Mathews PM, Florakis GJ, Trokel SL, Suh LH. Corneal collagen crosslinking in patients treated with dextran versus isotonic hydroxypropyl methylcellulose (HPMC) riboflavin solution: a retrospective analysis. EYE AND VISION 2018; 5:23. [PMID: 30214908 PMCID: PMC6130056 DOI: 10.1186/s40662-018-0116-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Accepted: 08/27/2018] [Indexed: 11/10/2022]
Abstract
Background Corneal collagen crosslinking (CXL) is a widely used treatment for halting the progression of keratoconus. Although initial studies of CXL were performed with a riboflavin solution containing dextran, recent protocols for CXL have indicated the use of a riboflavin solution containing isotonic hydroxypropyl methylcellulose (HPMC). This study was performed to investigate differences in visual outcomes and Scheimpflug (Pentacam) analysis in patients who have undergone epithelium-off CXL with riboflavin solution containing either 20% dextran versus 1.1% HPMC. Methods All patients in this non-randomized, non-masked, retrospective cohort analysis were treated at Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, NY, USA. Thirty-seven eyes of 33 patients were crosslinked with a dextran solution and 19 eyes of 19 patients crosslinked with an isotonic HPMC solution, both using an epithelium-off 30-min, 3 mW/cm2 protocol. All patients had a diagnosis of keratoconus or post-refractive surgery ectasia. Best spectacle corrected visual acuity (BSCVA) and Pentacam parameters were compared at all follow up visits (1, 6, 12, and 24 months). Differences between groups treated with HPMC and dextran were compared using student’s t-test. Differences between treated eye and fellow eye were calculated and compared between HPMC and dextran groups using paired t-test. Results Patients treated with a dextran solution had significantly greater improvement in BSCVA at 1, 6, and 24 months (p < 0.05) compared to the isotonic HPMC-treated group. Kmax increased in both groups at 1 month; however, HPMC-treated patients had a greater increase compared to dextran-treated patients (p = 0.01). Kmax decreased in both groups at 6 and 12 months, although this finding was only significant in the HPMC-treated group at 12 months. Conclusions Our data suggest that crosslinking with the dextran solution may result in significantly better visual outcomes (demonstrated by visual acuity) compared to the isotonic HPMC riboflavin solution. Dextran solutions may have other potential advantages intrinsic to its biochemical properties facilitating more efficient crosslinking. Further research and long-term evidence regarding the use of dextran versus HPMC riboflavin solutions in collagen crosslinking is necessary.
Collapse
Affiliation(s)
- Patrick B Rapuano
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia College of Physicians and Surgeons, 635 West 165th Street, New York, NY 10032 USA
| | - Priya M Mathews
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia College of Physicians and Surgeons, 635 West 165th Street, New York, NY 10032 USA
| | - George J Florakis
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia College of Physicians and Surgeons, 635 West 165th Street, New York, NY 10032 USA
| | - Stephen L Trokel
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia College of Physicians and Surgeons, 635 West 165th Street, New York, NY 10032 USA
| | - Leejee H Suh
- Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia College of Physicians and Surgeons, 635 West 165th Street, New York, NY 10032 USA
| |
Collapse
|
7
|
Correlation between central stromal demarcation line depth and changes in K values after corneal cross-linking (CXL). Graefes Arch Clin Exp Ophthalmol 2018; 256:759-764. [PMID: 29476249 PMCID: PMC5856899 DOI: 10.1007/s00417-018-3922-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 01/08/2018] [Accepted: 01/24/2018] [Indexed: 10/26/2022] Open
Abstract
PURPOSE A stromal demarcation line (DL) after corneal cross-linking (CXL) has lately been suggested as a surrogate parameter for the success of CXL. The aim of this study was to investigate the correlation between depth of the central DL 1 month and the change in K values 12 months after CXL. METHODS Treatment-naive subjects with keratoconus were treated using an accelerated CXL protocol [A-CXL(9*10)]. Depth of the DL/relative depth of the DL (DL%) was measured using Visante OCT imaging 1 month postoperatively (OP). Kmax/K2.5 (preOP) and change in Kmax/K2.5 (preOP - 12 months postOP) were assessed using corneal tomography (Pentacam HR, Oculus GmBH). RESULTS Forty eyes were treated following the A-CXL(9*10). The mean DL depth was 200 ± 99 μm (range 71 to 479)/mean DL% = 42.70 ± 20.00% (range 17-90). There was no statistically significant correlation between stromal depth of the DL and change in Kmax or K2.5, respectively (Spearman rho DL/∆Kmax - 0.14 and DL/∆K2.5 - 0.14). Between DL% and the changes in maximum K values or K2.5, no statistically significant correlation was found as well (Spearman rho DL%/∆Kmax - 0.10 and DL%/∆K2.5 - 0.19). Mean change in Kmax after 12 months was - 0.68 ± 2.26 diopters (D) (median - 0.35 D) and - 0.82 ± 1.6 D (median - 0.65 D) for K2.5 (p = 0.07; p = 0.02). CONCLUSIONS No statistically significant correlation was found between the stromal central depth of the DL and any outcome parameter for CXL after 12 months. Therefore, the interpretation of the DL as a predictive parameter for the effect of the procedure may not apply.
Collapse
|
8
|
Abstract
Corneal collagen cross-linking has become the preferred modality of treatment for corneal ectasia since its inception in late 1990s. Numerous studies have demonstrated the safety and efficacy of the conventional protocol. Our understanding of the cross-linking process is ever evolving, with its wide implications in the form of accelerated and pulsed protocols. Newer advancements in technology include various riboflavin formulations and the ability to deliver higher fluence protocols with customised irradiation patterns. A greater degree of customisation is likely the path forward, which will aim at achieving refractive improvements along with disease stability. The use of cross-linking for myopic correction is another avenue under exploration. Combination of half fluence cross-linking with refractive correction for high errors to prevent post LASIK regression is gaining interest. This review aims to highlight the various advancements in the cross-linking technology and its clinical applications.
Collapse
|
9
|
Intraoperative optical coherence tomography to evaluate the effect of the eyelid speculum on corneal pachymetry during accelerated corneal cross-linking (9 mW/cm 2). Eye (Lond) 2017; 32:579-585. [PMID: 29171504 DOI: 10.1038/eye.2017.243] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Accepted: 10/08/2017] [Indexed: 11/08/2022] Open
Abstract
PurposeTo investigate intraoperative anterior segment optical coherence tomography (AS-OCT) to compare pachymetry changes between two methods (group 1: speculum-on, group 2: speculum-off during riboflavin instillation stage) during corneal cross-linking /CXL) (9 mW/cm2 for 10 min) in keratoconic patients.MethodsIn this interventional case series, 11 eyes (11 patients) in group 1 and 14 eyes (14 patients) in group 2 were enrolled. Pachymetry measurements by spectral domain OCT was performed at baseline, after epithelial removal, after 30 min of imbibition with riboflavin, and after UV irradiation. Repeated measures analysis of variance was used to compare the trend of changes in different stages of the procedure within and between two groups.ResultsThe corneal thinnest pachymerty (CTP) at baseline, after epithelial removal, 30 min of riboflavin instillation, and irradiation was 469.8±26.5, 438.0±27.1, 354.3±28.4, 367.1±31.8 microns in group 1 and 463.2±25.1, 438.0±27.1, 421.6±54.0, 386.9±34.0 microns in group 2, respectively. Group 1 showed a significantly greater decrease in the corneal pachymetry (P<0.001) during riboflavin instillation, while in group 2 a greater decrease in CTP was observed during the UV irradiation phase (P=0.002).ConclusionsUsing the intraoperative OCT, the speculum-off group had a more stable corneal pachymetry during riboflavin instillation time. Despite this, the effect was not lasting throughout the procedure; significant changes were noted in the corneal pachymetry at the end of operation in both groups; further highlighting the limitations imposed by corneal stromal shrinkage using isotonic dextran containing riboflavin solution for CXL.
Collapse
|
10
|
Vastardis I, Pajic-Eggspuehler B, Nichorlis C, Mueller J, Pajic B. Recent Innovations in Collagen Corneal Cross-linking; a Mini Review. Open Ophthalmol J 2017; 11:217-224. [PMID: 28932338 PMCID: PMC5585451 DOI: 10.2174/1874364101711010217] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2017] [Revised: 03/13/2017] [Accepted: 06/14/2017] [Indexed: 11/22/2022] Open
Abstract
Background: The introduction of corneal cross-linking (CXL) with ultraviolet-A (UVA) and Riboflavin photosensitizer (Vit B2) from Seiler et al., revolutionized the treatment of Keratoconus and other corneal ectatic diseases. Today, the commonly known epithelium off Dresden protocol is in clinical use for the last 15 years with great success and regarded by many as the golden standard. Methods: With several studies demonstrating its simplicity, efficacy and safety this revolutionary method, paved the way for new therapies and strategies in the treatment of corneal ectatic diseases and changed our understanding in corneal biomechanics. Recent scientific and technological advances enabled the creation of various modifications of the initial CXL protocol and the formation of new ones. Conclusion: This work highlights the recent advances of CXL, such as the role of oxygen, higher fluence and shorter irradiation times as well as the various clinical applications and updates of this method.
Collapse
Affiliation(s)
- Iraklis Vastardis
- Swiss Eye Research Foundation, Eye Clinic ORASIS, Titlisstrasse 44, 5734 Reinach, Switzerland
| | | | - Charis Nichorlis
- Swiss Eye Research Foundation, Eye Clinic ORASIS, Titlisstrasse 44, 5734 Reinach, Switzerland
| | - Jörg Mueller
- Swiss Eye Research Foundation, Eye Clinic ORASIS, Titlisstrasse 44, 5734 Reinach, Switzerland.,University of Novi Sad, Faculty of Physics, Novi Sad, Serbia
| | - Bojan Pajic
- Swiss Eye Research Foundation, Eye Clinic ORASIS, Titlisstrasse 44, 5734 Reinach, Switzerland.,University of Novi Sad, Faculty of Physics, Novi Sad, Serbia.,Medical faculty, Military Medical Academy, University of defence Belgrade, Serbia
| |
Collapse
|
11
|
Höllhumer R, Watson S, Beckingsale P. Persistent Epithelial Defects and Corneal Opacity After Collagen Cross-Linking With Substitution of Dextran (T-500) With Dextran Sulfate in Compounded Topical Riboflavin. Cornea 2017; 36:382-385. [PMID: 28129292 DOI: 10.1097/ico.0000000000001134] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE Collagen cross-linking (CXL) is a commonly performed procedure to prevent the progression of keratoconus. Riboflavin is an essential part of the procedure, which facilitates both the cross-linking process and protection of intraocular structures. Dextran can be added to riboflavin to create an isotonic solution. This case report highlights the importance of compounding riboflavin with the correct dextran solution. METHODS A retrospective case series. RESULTS Six eyes of 4 male patients with keratoconus aged from 20 to 38 years underwent CXL with substitution of 20% dextran (T-500) with 20% dextran sulfate in a compounded riboflavin 0.1% solution. Postoperatively, persistent corneal epithelial defects, stromal haze, and then scarring occurred. Corneal transplantation was performed for visual rehabilitation but was complicated by graft rejection followed by failure (n = 1 eye), dehiscence (n = 4), cataract (n = 2), post-laser ablation haze (n = 1), and steroid-induced glaucoma (n = 2). The visual outcome was <6/18 in all 6 cases because of irregular astigmatism and stromal haze. Thinning, vascularization, and scarring of the residual host tissue were noted. CONCLUSIONS Substitution of dextran (T-500) with dextran sulfate in riboflavin solutions during CXL results in loss of vision from permanent corneal opacity. Residual host changes may compromise the results of corneal transplantation.
Collapse
Affiliation(s)
- Roland Höllhumer
- *Sydney Eye Hospital, Save Sight Institute, University of Sydney, Brisbane, Australia; †University of the Witwatersrand, Johannesburg, South Africa; and ‡Terrace Eye Centre, University of Queensland
| | | | | |
Collapse
|
12
|
|
13
|
Rechichi M, Mazzotta C, Daya S, Mencucci R, Lanza M, Meduri A. Intraoperative OCT Pachymetry in Patients Undergoing Dextran-Free Riboflavin UVA Accelerated Corneal Collagen Crosslinking. Curr Eye Res 2016; 41:1310-1315. [PMID: 26882478 DOI: 10.3109/02713683.2015.1118130] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To assess intraoperative corneal pachymetry in patients undergoing accelerated corneal collagen crosslinking with a dextran-free riboflavin solution. METHODS Prospective, non-comparative, multicenter interventional study. Thirty patients with progressive keratoconus were enrolled in the study from the Siena Crosslinking Center™ in Siena, Italy and the Eye Center in Catanzaro, Italy. The mean age was 26.9 ± 6.5 years. Patients underwent pulsed light accelerated crosslinking (PL-ACXL) by KXL I UV-A source (Avedro Inc., Waltham, MS, USA) with 8 min (1 s on/1 s off) of UV-A exposure, 30 mW/cm2 and an energy dose of 7.2 J/cm2. Corneal stroma was soaked with a dextran-free 0.1% riboflavin solution plus hydroxyl-propyl methylcellulose (HPMC) (VibeX Rapid, Avedro). Intraoperative corneal thickness was preoperatively (PRE-OP) evaluated by corneal optical coherence tomography (iVUE Optovue Inc., Fremont, CA, USA) after epithelium removal (EPI-R), after 10 min of riboflavin soaking (RS) and after UV-A irradiation (IR). Statistical analysis was conducted using a Wilcoxon test and SPSS v16.0. A p-value of <0.05 was considered to be statistically significant. RESULTS Average PRE-OP central corneal thickness (CCT) and thinnest corneal thickness (TCT) were 437.3 ± 36.9 and 418.9 ± 28.8 μm, respectively. Average EPI-R CCT and TCT values were 388.5 ± 36.8 and 381.5 ± 36.61 μm, respectively. Average CCT and TCT values after 10 min RS were 385.2 ± 37.8 and 380.6 ± 36.7 μm, respectively. The final average CCT and TCT values after IR were 379.4 ± 37.2 and 378.1 ± 36.4 μm, respectively. CONCLUSIONS The study demonstrated a non-statistically significant intraoperative corneal thickness reduction in patients undergoing PL-ACXL corneal collagen crosslinking by using dextran free HPMC 0.1% riboflavin solution.
Collapse
Affiliation(s)
| | - Cosimo Mazzotta
- b Ophthalmology Unit , Siena University Hospital , Siena , Italy
| | | | | | - Michele Lanza
- e Multidisciplinary Department of Medical , Surgical and Dental Sciences, Second University of Naples , Naples , Italy
| | - Alessandro Meduri
- f Department of Ophthalmology , University of Messina , Messina , Italy
| |
Collapse
|
14
|
In Vivo Thermographic Analysis of the Corneal Surface in Keratoconic Patients Undergoing Riboflavin–UV-A Accelerated Cross-Linking. Cornea 2015; 34:323-7. [DOI: 10.1097/ico.0000000000000324] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
|
16
|
Pulsed vs continuous light accelerated corneal collagen crosslinking: in vivo qualitative investigation by confocal microscopy and corneal OCT. Eye (Lond) 2014; 28:1179-83. [PMID: 25060847 DOI: 10.1038/eye.2014.163] [Citation(s) in RCA: 91] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2013] [Accepted: 05/23/2014] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To assess qualitative corneal changes and penetration of pulsed and continuous light accelerated crosslinking by in vivo confocal microscopy and corneal OCT. METHODS A total of 20 patients affected from progressive keratoconus were enrolled in the study. Ten eyes of 10 patients underwent an epithelium-off pulsed-light accelerated corneal collagen crosslinking (PL-ACXL) by the KXL UV-A source (Avedro Inc.) with 8 min (1 s on/1 s off) of UV-A exposure at 30 mW/cm(2) and energy dose of 7.2 J/cm(2); 10 eyes of 10 patients underwent an epithelium-off continuous-light accelerated corneal collagen crosslinking (CL-ACXL) at 30 mW/cm(2) for 4 min. Riboflavin 0.1% dextran-free plus hydroxyl-propyl-methylcellulose solution (VibeX Rapid, Avedro Inc.) was used for a 10-min corneal soaking. Treated eyes were examined by in vivo scanning laser confocal analysis and spectral anterior segment OCT at 1, 3, and 6 months. RESULTS Epithelial stratification and nerves regeneration improved in time, being complete at month 6 in both groups without endothelial damage. Keratocyte apoptosis in PL-ACXL was estimated at a mean depth of ∼200 μm, whereas an uneven demarcation line was detectable by confocal microscopy at a mean depth of 160 μm in CL-ACXL. CONCLUSION In vivo confocal microscopy and corneal OCT allowed a precise qualitative analysis of the cornea after epithelium-off PL-ACXL and CL-ACXL treatments. Apoptotic effect was higher in pulsed than in continuous light treatments, exceeding 200 μm in corneal stroma. According to different morphological data, the clinical efficacy of ACXL needs to be determined in a long-term follow-up and large cohort of patients.
Collapse
|
17
|
Chan CC, Squissato V. Keratoconus and crosslinking: pharmacokinetic considerations. Expert Opin Drug Metab Toxicol 2013; 9:1613-24. [DOI: 10.1517/17425255.2013.834886] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|