Wooldridge J, Arduino A, Zilberti L, Zanovello U, Chiampi M, Clementi V, Bottauscio O. Gradient coil and radiofrequency induced heating of orthopaedic implants in MRI: influencing factors. Phys Med Biol 2021; 66. [PMID: 34847533 DOI: 10.1088/1361-6560/ac3eab] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 11/30/2021] [Indexed: 11/12/2022]
Abstract
Patients with implanted orthopaedic devices represent a growing number of subjects undergoing magnetic resonance imaging (MRI) scans each year. MRI safety labelling is required for all implants under the EU Medical Device Regulations to ensure regulatory compliance, with each device assessed through standardised testing procedures. In this paper, we employ parametric studies to assess a range of clinically relevant factors that cause tissue heating, performing simulations with both radiofrequency (RF) and gradient coil (GC) switching fields, the latter of which is often overlooked in the literature. A series of 'worst-case' scenarios for both types of excitation field is discussed. In the case of GC fields, large volume implants and large plate areas with the field orientated perpendicular to the plane cause the highest heating levels, along with sequences with high rates of field switching. Implant heating from RF fields is driven primarily from the 'antenna effect', with thin, linear implants of resonant length resulting in the highest temperature rises. In this work, we show that simplifications may be made to the field sequence and in some cases the device geometry without significantly compromising the accuracy of the simulation results, enabling the possibility for generic estimates of the implant heating for orthopaedic device manufacturers and opportunities to simplify the safety compliance process.
Collapse
Affiliation(s)
- J Wooldridge
- National Physical Laboratory, Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom
| | - A Arduino
- Istituto Nazionale di Ricerca Metrologica, Str. delle Cacce, 91, I-10135 Torino TO, Italy
| | - L Zilberti
- Istituto Nazionale di Ricerca Metrologica, Str. delle Cacce, 91, I-10135 Torino TO, Italy
| | - U Zanovello
- Istituto Nazionale di Ricerca Metrologica, Str. delle Cacce, 91, I-10135 Torino TO, Italy
| | - M Chiampi
- Istituto Nazionale di Ricerca Metrologica, Str. delle Cacce, 91, I-10135 Torino TO, Italy
| | - V Clementi
- IRCCS Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica, Via di Barbiano 1/10, I-40136 Bologna, Italy
| | - O Bottauscio
- Istituto Nazionale di Ricerca Metrologica, Str. delle Cacce, 91, I-10135 Torino TO, Italy
| |
Collapse
|
2
|
Noetscher GM, Serano P, Wartman WA, Fujimoto K, Makarov SN. Visible Human Project® female surface based computational phantom (Nelly) for radio-frequency safety evaluation in MRI coils. PLoS One 2021; 16:e0260922. [PMID: 34890429 PMCID: PMC8664205 DOI: 10.1371/journal.pone.0260922] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 11/19/2021] [Indexed: 11/19/2022] Open
Abstract
Quantitative modeling of specific absorption rate and temperature rise within the human body during 1.5 T and 3 T MRI scans is of clinical significance to ensure patient safety. This work presents justification, via validation and comparison, of the potential use of the Visible Human Project (VHP) derived Computer Aided Design (CAD) female full body computational human model for non-clinical assessment of female patients of age 50–65 years with a BMI of 30–36 during 1.5 T and 3 T based MRI procedures. The initial segmentation validation and four different application examples have been identified and used to compare to numerical simulation results obtained using VHP Female computational human model under the same or similar conditions. The first application example provides a simulation-to-simulation validation while the latter three application examples compare with measured experimental data. Given the same or similar coil settings, the computational human model generates meaningful results for SAR, B1 field, and temperature rise when used in conjunction with the 1.5 T birdcage MRI coils or at higher frequencies corresponding to 3 T MRI. Notably, the deviation in temperature rise from experiment did not exceed 2.75° C for three different heating scenarios considered in the study with relative deviations of 10%, 25%, and 20%. This study provides a reasonably systematic validation and comparison of the VHP-Female CAD v.3.0–5.0 surface-based computational human model starting with the segmentation validation and following four different application examples.
Collapse
Affiliation(s)
- Gregory M. Noetscher
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts, United States of America
- NEVA Electromagnetics, LLC, Yarmouth Port, Massachusetts, United States of America
- * E-mail:
| | - Peter Serano
- Ansys, Inc., Canonsburg, Pennsylvania, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States of America
| | - William A. Wartman
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts, United States of America
| | - Kyoko Fujimoto
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, United States of America
| | - Sergey N. Makarov
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts, United States of America
- NEVA Electromagnetics, LLC, Yarmouth Port, Massachusetts, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, United States of America
| |
Collapse
|
3
|
Bhuva AN, Moralee R, Moon JC, Manisty CH. Making MRI available for patients with cardiac implantable electronic devices: growing need and barriers to change. Eur Radiol 2019; 30:1378-1384. [PMID: 31776746 PMCID: PMC7033076 DOI: 10.1007/s00330-019-06449-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 08/02/2019] [Accepted: 09/12/2019] [Indexed: 11/22/2022]
Abstract
Abstract More than half of us will need a magnetic resonance imaging (MRI) scan in our lifetimes. MRI is an unmatched diagnostic test for an expanding range of indications including neurological and musculoskeletal disorders, cancer diagnosis, and treatment planning. Unfortunately, patients with cardiac pacemakers or defibrillators have historically been prevented from having MRI because of safety concerns. This results in delayed diagnoses, more invasive investigations, and increased cost. Major developments have addressed this—newer devices are designed to be safe in MRI machines under specific conditions, and older legacy devices can be scanned provided strict protocols are followed. This service however remains difficult to deliver sustainably worldwide: MRI provision remains grossly inadequate because patients are less likely to be referred, and face difficulties accessing services even when referred. Barriers still exist but are no longer technical. These include logistical hurdles (poor cardiology and radiology interaction at physician and technician levels), financial incentives (re-imbursement is either absent or fails to acknowledge the complexity), and education (physicians self-censor MRI requests). This article therefore highlights the recent changes in the clinical, logistical, and regulatory landscape. The aim of the article is to enable and encourage healthcare providers and local champions to build MRI services urgently for cardiac device patients, so that they may benefit from the same access to MRI as everyone else. Key Points • There is now considerable evidence that MRI can be provided safely to patients with cardiac implantable electronic devices (CIEDs). However, the volume of MRI scans delivered to patients with CIEDs is fifty times lower than that of the estimated need, and patients are approximately fifty times less likely to be referred. • Because scans for this patient group are frequently for cancer diagnosis and treatment planning, MRI services need to develop rapidly, but the barriers are no longer technical. • New services face logistical, educational, and financial hurdles which can be addressed effectively to establish a sustainable service at scale.
Collapse
Affiliation(s)
- A N Bhuva
- Department of Cardiac Imaging, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK. .,Institute for Cardiovascular Science, University College London, London, UK.
| | - R Moralee
- Department of Cardiac Imaging, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK
| | - J C Moon
- Department of Cardiac Imaging, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.,Institute for Cardiovascular Science, University College London, London, UK
| | - C H Manisty
- Department of Cardiac Imaging, Barts Heart Centre, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.,Institute for Cardiovascular Science, University College London, London, UK
| |
Collapse
|
4
|
Kalloch B, Bode J, Kozlov M, Pampel A, Hlawitschka M, Sehm B, Villringer A, Möller HE, Bazin PL. Semi-automated generation of individual computational models of the human head and torso from MR images. Magn Reson Med 2018; 81:2090-2105. [PMID: 30230021 DOI: 10.1002/mrm.27508] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 07/05/2018] [Accepted: 08/04/2018] [Indexed: 11/08/2022]
Abstract
PURPOSE Simulating the interaction of the human body with electromagnetic fields is an active field of research. Individualized models are increasingly being used, as anatomical differences affect the simulation results. We introduce a processing pipeline for creating individual surface-based models of the human head and torso for application in simulation software based on unstructured grids. The pipeline is designed for easy applicability and is publicly released on figshare. METHODS The pipeline covers image acquisition, segmentation, generation of segmentation masks, and surface mesh generation of the single, external boundary of each structure of interest. Two gradient-echo sequences are used for image acquisition. Structures of the head and body are segmented using several atlas-based approaches. They consist of bone/skull, subarachnoid cerebrospinal fluid, gray matter, white matter, spinal cord, lungs, the sinuses of the skull, and a combined class of all other structures including skin. After minor manual preparation, segmentation images are processed to segmentation masks, which are binarized images per segmented structure free of misclassified voxels and without an internal boundary. The proposed workflow is applied to 2 healthy subjects. RESULTS Individual differences of the subjects are well represented. The models are proven to be suitable for simulation of the RF electromagnetic field distribution. CONCLUSION Image segmentation, creation of segmentation masks, and surface mesh generation are highly automated. Manual interventions remain for preparing the segmentation images prior to segmentation mask generation. The generated surfaces exhibit a single boundary per structure and are suitable inputs for simulation software.
Collapse
Affiliation(s)
- Benjamin Kalloch
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.,Leipzig University of Applied Sciences, Leipzig, Germany
| | - Jens Bode
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.,Department of Engineering Physics, University of Applied Sciences Münster, Münster, Germany
| | - Mikhail Kozlov
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - André Pampel
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | | | - Bernhard Sehm
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Arno Villringer
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Harald E Möller
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Pierre-Louis Bazin
- Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.,Netherlands Institute for Neuroscience, Amsterdam, Netherlands.,Spinoza Centre for Neuroimaging, Amsterdam, Netherlands
| |
Collapse
|
5
|
Occupational exposure to electromagnetic fields in magnetic resonance environment: basic aspects and review of exposure assessment approaches. Med Biol Eng Comput 2018; 56:531-545. [PMID: 29344902 DOI: 10.1007/s11517-017-1779-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Accepted: 12/17/2017] [Indexed: 10/18/2022]
Abstract
The purpose of this review is to make a contribution to build a comprehensive knowledge of the main aspects related to the occupational exposure to electromagnetic fields (EMFs) in magnetic resonance imaging (MRI) environments. Information has been obtained from original research papers published in international peer-reviewed journals in the English language and from documents published by governmental bodies and authorities. An overview of the occupational exposure scenarios to static magnetic fields, motion-induced, time-varying magnetic fields, and gradient and radiofrequency fields is provided, together with a summary of the relevant regulation for limiting exposure. A particular emphasis is on reviewing the main EMF exposure assessment approaches found in the literature. Exposure assessment is carried out either by measuring the unperturbed magnetic fields in the MRI rooms, or by personal monitoring campaigns, or by the use of numerical methods. A general lack of standardization of the procedures and technologies adopted for exposure assessment has emerged, which makes it difficult to perform a direct comparison of results from different studies carried out by applying different assessment strategies. In conclusion, exposure assessment approaches based on data collection and numerical models need to be better defined in order to respond to specific research questions. That would provide for a more complete characterization of the exposure patterns and for identification of the factors determining the exposure variability. Graphical abstract Main approaches adopted in the literature to perform occupational exposure assessment to electromagnetic fields (EMFs) in magnetic resonance imaging (MRI) environments. SMF: static magnetic field; GMF: gradient magnetic fields; RF: radio-frequencies.
Collapse
|