1
|
Khaohoen A, Powcharoen W, Sornsuwan T, Chaijareenont P, Rungsiyakull C, Rungsiyakull P. Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials. BMC Oral Health 2024; 24:359. [PMID: 38509530 PMCID: PMC10956322 DOI: 10.1186/s12903-024-04033-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 02/14/2024] [Indexed: 03/22/2024] Open
Abstract
This systematic review explores the accuracy of computerized guided implant placement including computer-aided static, dynamic, and robot-assisted surgery. An electronic search up to February 28, 2023, was conducted using the PubMed, Embase, and Scopus databases using the search terms "surgery", "computer-assisted", "dynamic computer-assisted", "robotic surgical procedures", and "dental implants". The outcome variables were discrepancies including the implant's 3D-coronal, -apical and -angular deviations. Articles were selectively retrieved according to the inclusion and exclusion criteria, and the data were quantitatively meta-analysed to verify the study outcomes. Sixty-seven articles were finally identified and included for analysis. The accuracy comparison revealed an overall mean deviation at the entry point of 1.11 mm (95% CI: 1.02-1.19), and 1.40 mm (95% CI: 1.31-1.49) at the apex, and the angulation was 3.51˚ (95% CI: 3.27-3.75). Amongst computerized guided implant placements, the robotic system tended to show the lowest deviation (0.81 mm in coronal deviation, 0.77 mm in apical deviation, and 1.71˚ in angular deviation). No significant differences were found between the arch type and flap operation in cases of dynamic navigation. The fully-guided protocol demonstrated a significantly higher level of accuracy compared to the pilot-guided protocol, but did not show any significant difference when compared to the partially guided protocol. The use of computerized technology clinically affirms that operators can accurately place implants in three directions. Several studies agree that a fully guided protocol is the gold standard in clinical practice.
Collapse
Affiliation(s)
- Angkoon Khaohoen
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Warit Powcharoen
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Tanapon Sornsuwan
- Department of Restorative Dentistry, Faculty of Dentistry, Naresuan University, Phitsanulok, 65000, Thailand
| | - Pisaisit Chaijareenont
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Chaiy Rungsiyakull
- Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Pimduen Rungsiyakull
- Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, 50200, Thailand.
| |
Collapse
|
2
|
Zevallos EAA, Lima LHF, Mendes KLC, Sverzut AT. Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2024:101828. [PMID: 38508394 DOI: 10.1016/j.jormas.2024.101828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2024] [Revised: 03/13/2024] [Accepted: 03/15/2024] [Indexed: 03/22/2024]
Abstract
OBJECTIVES The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. STUDY DESIGN This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. RESULTS The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. CONCLUSION The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method.
Collapse
Affiliation(s)
| | | | - Karine Laura Cortellazzi Mendes
- Department of Health Sciences and Children's Dentistry, Piracicaba Dental School, University of Campinas, UNICAMP, Piracicaba, SP, Brazil
| | - Alexander Tadeu Sverzut
- Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, UNICAMP, Piracicaba, SP, Brazil.
| |
Collapse
|
3
|
de Almeida JC, Soares MQS, Mamani MP, Franco A, Junqueira JLC. Influence of surgeon experience on implant placement in guided surgeries: A systematic review and meta-analysis of randomized clinical trials. J Prosthet Dent 2024:S0022-3913(24)00004-0. [PMID: 38336565 DOI: 10.1016/j.prosdent.2024.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 01/06/2024] [Accepted: 01/08/2024] [Indexed: 02/12/2024]
Abstract
STATEMENT OF PROBLEM Guided surgical techniques in implant dentistry use virtual planning to accurately position implants. Understanding the effect of a surgeon's experience on guided surgery is essential to ensure successful outcomes. PURPOSE The purpose of this systematic review and meta-analysis of randomized clinical trials was to evaluate the influence of a surgeon's experience on the accuracy of implant positioning in guided surgery for completely or partially edentulous patients. MATERIAL AND METHODS Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines, searches were conducted in the PubMed, Scopus, Web of Science, EMBASE, Cochrane Library, SciELO, and nonpeer-reviewed literature databases. Studies that met the population, intervention, control, and outcome (PICO) strategy were included: a completely or partially edentulous maxilla or mandible, guided surgery performed by experienced and inexperienced surgeons, and assessing implant positioning accuracy. A random-effects meta-analysis with a 95% confidence interval was conducted using Stata 15.1. The risk of bias was assessed with the Cochrane risk-of-bias tool for randomized trials (RoB2), and evidence certainty was evaluated using the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) tool. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) database (CRD42022302288). RESULTS Three articles from 2017 to 2020 encompassing 43 participants (22 men and 21 women) with a mean age of 61.2 years and a total of 150 implants were included. No significant difference was found between experienced and inexperienced surgeons in terms of angular, cervical, or apical deviations of the implants (95% confidence interval, P<.05). The difference between surgeons regarding positioning accuracy was less than 0.01 degrees for angular deviation, 0.35 mm for apical deviation, and 0.16 mm for cervical deviation. Low heterogeneity was observed for angular deviations (Q P=.021, I2=34%, and t2<.001) and cervical deviations (Q P=.18, I2=45%, and t2=.064). High heterogeneity was observed for apical deviations (Q P<.001, I2=87% and t2=.522). The overall bias risk was moderate, with the evidence certainty ranging from low to moderate. CONCLUSIONS In guided surgery, the surgeon's experience did not significantly impact the occurrence of deviations in implant positioning.
Collapse
Affiliation(s)
| | | | | | - Ademir Franco
- Professor, Forensic Odontology Division, São Leopoldo Mandic Research Institute (SLM), Campinas, Brazil
| | | |
Collapse
|
4
|
Mittal S, Kaurani P, Goyal R. Comparison of accuracy between single posterior immediate and delayed implants placed using computer guided implant surgery and a digital laser printed surgical guide: A clinical investigation. J Prosthet Dent 2024:S0022-3913(23)00816-8. [PMID: 38218708 DOI: 10.1016/j.prosdent.2023.11.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Revised: 11/20/2023] [Accepted: 11/21/2023] [Indexed: 01/15/2024]
Abstract
STATEMENT OF PROBLEM The congruence of surgical implant placement with the preplanned position is important for anatomic and prosthetic precision, minimal complications, and increased longevity. The influence of implant placement timing on the surgical deviations in single posterior implants is unclear. PURPOSE The purpose of this clinical study was to compare deviations between preplanned and single posterior immediate and delayed implants placed using computer-guided digital light processing (DLP) surgical guides fabricated using intraoral scanning and cone beam computed tomography (CBCT). MATERIAL AND METHODS Implant surgery was performed on 24 participants requiring single immediate or delayed implants in the posterior maxillary and mandibular regions, for which the surgical site data were obtained from CBCT and intraoral scanning. Subsequently, virtual implant planning and DLP surgical guides were fabricated. Preimplant and postimplant placement CBCT scans were overlapped, and mean deviations for the immediate and delayed implant groups were calculated. The groups were compared with unpaired t tests (α=.05). RESULTS A total of 24 implants were placed, 12 in each group. In participants who received immediate implant placement, the mean ±standard deviation angular deviation, linear deviation at shoulder, linear deviation at apex, and vertical deviation were 1.03 ±0.70 degrees, 0.26 ±0.30 mm, 0.23 ±0.24 mm, and 0.39 ± 0.34 mm, respectively. In participants who received delayed implant treatment, the deviations were 0.53 ±0.60 degrees, 0.15 ±0.18 mm, 0.25 ±0.33 mm, and 0.17 ±0.10 mm, respectively. Significant differences between the 2 groups were found in the vertical deviation (P<.05). CONCLUSIONS The timing of the single posterior placement was associated with different deviations in the vertical direction. All deviations obtained were below the recommended values. DLP surgical guides fabricated from intraoral and CBCT scans provided accurate implant placement in immediate and delayed single posterior implants.
Collapse
Affiliation(s)
- Sankalp Mittal
- Head of Department, Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Jaipur, India.
| | - Pragati Kaurani
- Professor, Department of Prosthodontics Crown and Bridge, Mahatma Gandhi Dental College and Hospital, Jaipur, India
| | - Ritika Goyal
- Postgraduate student, Department of Prosthodontics Crown and Bridge, Mahatma Gandhi Dental College and Hospital, Jaipur, India
| |
Collapse
|
5
|
Accuracy of keyless vs drill-key implant systems for static computer-assisted implant surgery using two guide-hole designs compared to freehand implant placement: an in vitro study. Int J Implant Dent 2023; 9:4. [PMID: 36749441 PMCID: PMC9905371 DOI: 10.1186/s40729-023-00470-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/31/2023] [Indexed: 02/08/2023] Open
Abstract
PURPOSE This in vitro study aimed at comparing the accuracy of freehand implant placement with static computer-assisted implant surgery (sCAIS), utilizing a keyless and a drill-key implant system and two guide-hole designs. METHODS A total of 108 implants were placed in 18 partially edentulous maxillary models simulating two different alveolar ridge morphologies. 3D digital deviations between pre-planned and post-operative implant positions were obtained. Guide material reduction was assessed in the keyless implant system for the manufacturer's sleeve and sleeveless guide-hole designs. RESULTS sCAIS using a sleeveless guide-hole design demonstrated smaller mean angular, crestal and apical deviations compared to sCAIS utilizing a manufacturer's sleeve and the freehand group (2.6 ± 1.6°, vs 3.3 ± 1.9°, vs 4.0 ± 1.9°; 0.5 ± 0.3 mm, vs 0.6 ± 0.3 mm, vs 0.8 ± 0.3 mm; and 1.0 ± 0.5 mm, vs 1.2 ± 0.7 mm, vs 1.5 ± 0.6 mm). Smaller angular and apical mean deviations were observed in the keyless implant system as compared with the drill-key implant system (3.1 ± 1.7°, vs 3.5 ± 1.9°, p = 0.03; and 1.2 ± 0.6 mm, vs 1.4 ± 0.7 mm, p = 0.045). Overall, smaller angular, crestal, and apical deviations (p < 0.0001) were observed in healed alveolar ridges (2.4 ± 1.7°, 0.5 ± 0.3 mm, and 0.9 ± 0.5 mm) than in extraction sockets (4.2 ± 1.6°, 0.8 ± 0.3 mm, and 1.6 ± 0.5 mm). Higher mean volumetric material reduction was observed in sleeveless than in manufacturer's sleeve guide-holes (- 0.10 ± 0.15 mm3, vs - 0.03 ± 0.03 mm3, p = 0.006). CONCLUSIONS Higher final implant positional accuracy was observed in sCAIS for the keyless implant system, with a sleeveless guide-hole design, and in healed ridges. Sleeveless guide holes resulted in higher volumetric material reduction compared with the manufacturer's sleeve.
Collapse
|
6
|
Huang L, Zhang X, Mo A. A Retrospective Study on the Transferring Accuracy of a Fully Guided Digital Template in the Anterior Zone. MATERIALS 2021; 14:ma14164631. [PMID: 34443154 PMCID: PMC8399113 DOI: 10.3390/ma14164631] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 06/27/2021] [Accepted: 08/09/2021] [Indexed: 02/05/2023]
Abstract
The accuracy of implant placement with a fully guided digital template can be influenced by many factors, such as arch difference, alveolar bone density, timing of implant placement and open flap. The purpose of this article was to evaluate the factors presumptively affecting the accuracy of implant placement assisted by the fully guided template in the anterior zone. In 40 patients with missing anterior teeth, a total of 52 implants were placed with tooth-borne, fully guided templates after CBCT evaluation, in West China Hospital of Stomatology, Sichuan University. After overlapping the pre-and post-operative DICOM data, measurements were taken in the dental implant planning software (Nobel Clinician®) to calculate linear and angular deviations between virtual placement plan and actual implant placement. Grouping was categorized according to three factors that possibly have an influence on accuracy: arch type (maxilla/mandible), timing of implant placement (immediate/delayed), surgical technique (open flap/flapless). The data was analyzed with independent sample t-test (p < 0.05). The results showed that the apical, coronal, depth and angular mean deviations of implant positions in anterior zone were 1.13 ± 0.39 mm, 0.86 ± 0.33 mm, 0.41 ± 0.66 mm, 3.32 ± 1.65° with the fully guided templates. The accuracy at apex level, coronal level and the angulation were similar between the maxilla and mandible, and the magnitude of all four deviations between immediate and delayed implantation, open flap and flapless technique were small. No statistically significant difference was observed (p > 0.05). Whereas there was significant difference in depth deviation between maxilla and mandible (p < 0.05). Conclusively, the implant site, alveolar bone density, timing of implant placement and surgical techniques merely compromise the implant placement accuracy under the assistance of a fully guided template.
Collapse
|
7
|
Chen YW, Hanak BW, Yang TC, Wilson TA, Hsia JM, Walsh HE, Shih HC, Nagatomo KJ. Computer-assisted surgery in medical and dental applications. Expert Rev Med Devices 2021; 18:669-696. [PMID: 33539198 DOI: 10.1080/17434440.2021.1886075] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Computer-assisted surgery (CAS) is a broad surgical methodology that utilizes computer technology to both plan and execute surgical intervention. CAS is widespread in both medicine and dentistry as it allows for minimally invasive and precise surgical procedures. Key innovations in volumetric imaging, virtual surgical planning software, instrument tracking, and robotics have assisted in facilitating the transfer of surgical plans to precise execution of surgical procedures. CAS has long been used in certain medical specialties including neurosurgery, cardiology, orthopedic surgery, otolaryngology, and interventional radiology, and has since expanded to oral and maxillofacial application, particularly for computer-assisted implant surgery. AREAS COVERED This review provides an updated overview of the most current research for CAS in medicine and dentistry, with a focus on neurosurgery and dental implant surgery. The MEDLINE electronic database was searched and relevant original and review articles from 2005 to 2020 were included. EXPERT OPINION Recent literature suggests that CAS performs favorably in both neurosurgical and dental implant applications. Computer-guided surgical navigation is well entrenched as standard of care in neurosurgery. Whereas static computer-assisted implant surgery has become established in dentistry, dynamic computer-assisted navigation is newly poised to trend upward in dental implant surgery.
Collapse
Affiliation(s)
- Yen-Wei Chen
- Department of Restorative Dentistry, University of Washington School of Dentistry Seattle,98195, WA, USA
| | - Brian W Hanak
- Department of Neurosurgery, Loma Linda University Health Loma Linda, 92354, CA, USA
| | - Tzu-Chian Yang
- Department of Restorative Dentistry, University of Washington School of Dentistry Seattle,98195, WA, USA
| | - Taylor A Wilson
- Department of Neurosurgery, Loma Linda University Health Loma Linda, 92354, CA, USA
| | - Jenovie M Hsia
- Department of Restorative Dentistry, University of Washington School of Dentistry Seattle,98195, WA, USA
| | - Hollie E Walsh
- Department of Restorative Dentistry, University of Washington School of Dentistry Seattle,98195, WA, USA
| | - Huai-Che Shih
- Department of Restorative Dentistry, University of Washington School of Dentistry Seattle,98195, WA, USA
| | - Kanako J Nagatomo
- Department of Periodontics, University of Washington School of Dentistry Seattle,98195 WA,USA
| |
Collapse
|
8
|
Putra RH, Yoda N, Astuti ER, Sasaki K. The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis. J Prosthodont Res 2021; 66:29-39. [PMID: 33504723 DOI: 10.2186/jpr.jpr_d_20_00184] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To review the current clinical studies regarding the accuracy of implant computer-guided surgery in partially edentulous patients and investigate potential influencing factors. STUDY SELECTION Electronic searches on the PubMed and Cochrane Central Register of Controlled Trials databases, and subsequent manual searches were performed. Two reviewers selected the studies following our inclusion and exclusion criteria. Qualitative review and meta-analysis of the implant placement accuracy were performed to analyze potential influencing factors. Angular deviation, coronal deviation, apical deviation, and depth deviation were evaluated as the accuracy outcomes. RESULTS Eighteen studies were included in this systematic review, including six randomized controlled trials, nine prospective studies, and three retrospective clinical studies. A total of 1317 implants placed in 642 partially edentulous patients were reviewed. Eight studies were evaluated using meta-analysis. Fully guided surgery showed statistically higher accuracy in angular (P <0.001), coronal (P <0.001), and apical deviation (P <0.05) compared with pilot-drill guided surgery. A statistically significant difference (P <0.001) was also observed in coronal deviation between the bounded edentulous (BES) and distal extension spaces (DES). A significantly lower angular deviation (P <0.001) was found in implants placed using computer-aided design/computer-aided manufacturing (CAD/CAM) compared to the conventional surgical guides. CONCLUSIONS The edentulous space type, surgical guide manufacturing procedure, and guided surgery protocol can influence the accuracy of computer-guided surgery in partially edentulous patients. Higher accuracy was found when the implants were placed in BES, with CAD/CAM manufactured surgical guides, using a fully guided surgery protocol.
Collapse
Affiliation(s)
- Ramadhan Hardani Putra
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry.,Department of Dentomaxillofacial Radiology, Faculty of Dental Medicine, Universitas Airlangga
| | - Nobuhiro Yoda
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
| | - Eha Renwi Astuti
- Department of Dentomaxillofacial Radiology, Faculty of Dental Medicine, Universitas Airlangga
| | - Keiichi Sasaki
- Division of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry
| |
Collapse
|
9
|
Zhang X, Wang M, Mo A. An alternative method for immediate implant-supported restoration of anterior teeth assisted by fully guided templates: A clinical study. J Prosthet Dent 2020; 126:636-645. [PMID: 33008632 DOI: 10.1016/j.prosdent.2020.05.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Revised: 05/20/2020] [Accepted: 05/20/2020] [Indexed: 02/05/2023]
Abstract
STATEMENT OF PROBLEM Immediate implant-supported restorations have become a common treatment strategy in the esthetic zone; however, improvements are necessary in the techniques used to fabricate interim prostheses. PURPOSE This clinical study evaluated an alternative method for the immediate restoration of anterior teeth by using a fully guided template. MATERIAL AND METHODS Twenty-five participants were enrolled, and 30 implants were inserted by using fully guided templates. Eleven participants and 14 implant sites were treated with immediate implant placement. Fourteen participants and 16 implant sites were treated with delayed implant placement. The same method was used for immediate restoration in all the participants. A postoperative cone beam computed tomography (CBCT) scan was compared with the preoperative planning to measure the deviation between the placed and the planned implants. The independent t test was used for the comparison of immediate and delayed implant placement (α=.05). Any complications occurring in the following 3 months were also recorded. RESULTS None of the interim prostheses needed significant adjustments and were successfully installed on implants after the surgery. The overall mean deviations in 3D coronal, buccolingual coronal, mesiodistal coronal, 3D apical, buccolingual apical, mesiodistal apical, depth, and angle were 0.6 ±0.3 mm, 0.4 ±0.2 mm, 0.2 ±0.1 mm, 1.0 ±0.4 mm, 0.7 ±0.4 mm, 0.3 ±0.2 mm, 0.4 ±0.3 mm, and 1.9 ±1.1 degrees, respectively. The linear and angular deviations exhibited no significant differences (P>.05) between immediate and delayed implant placement. No complications developed in the follow-up period. CONCLUSIONS In the anterior esthetic zone, this alternative method appears to be suitable for immediate restoration. The accuracy of fully guided surgery was clinically acceptable for the prefabricated interim prostheses and helped reduce postoperative chairside time.
Collapse
Affiliation(s)
- Xiaoqing Zhang
- Graduate student, State Key Laboratory of Oral Diseases, Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Maoxia Wang
- Graduate student, State Key Laboratory of Oral Diseases, Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Anchun Mo
- Professor, State Key Laboratory of Oral Diseases, Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
| |
Collapse
|
10
|
Unsal GS, Turkyilmaz I, Lakhia S. Advantages and limitations of implant surgery with CAD/CAM surgical guides: A literature review. J Clin Exp Dent 2020; 12:e409-e417. [PMID: 32382391 PMCID: PMC7195681 DOI: 10.4317/jced.55871] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 02/02/2020] [Indexed: 12/19/2022] Open
Abstract
Background The purpose of this study is to review the available literature associated with implant surgery using computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides and discuss the advantages and disadvantages of this advanced technique.
Material and Methods An electronic literature search was conducted in the PubMed database for the relevant information on implant placement with CAD/CAM surgical guides. This review was constructed following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Articles were limited to those published within the past 10 years and in the English language. Only clinical studies were included. Inclusion criteria were: studies including 10 implants or more and studies presenting angular deviations in degrees and linear deviations in millimeter. Observational studies, reviews, animal studies, in vitro studies, case reports, simulation studies were excluded. Nine articles were included for qualitative synthesis.
Results The initial search detected 61 articles, and after screening abstracts, a total of 15 articles were selected for full-text review. After the full-text analysis of the 15 articles, six articles were excluded as they did not meet inclusion criteria for study design, study population, and implant placement with data presentation for angular and linear deviations. Ultimately, nine articles providing angular and linear deviations between planned and actual placed implants were used in this review. Common problems that may be encountered by clinicians were listed, and recommendations were made on how to avoid those problems.
Conclusions It has been suggested that although unrealistic expectations are often associated with implant placement with CAD/CAM surgical guides, there is no impeccable accuracy in the clinic. This review demonstrated that the practitioners should be aware of the angular and linear deviations up to 5 ° and 2.3 mm. Therefore, inexperienced dentists should obtain adequate training and be familiar with the basic steps with CAD/CAM surgical guides to avoid complications. Key words:CAD/CAM, CBCT, implant, stereolithography, surgical guide.
Collapse
Affiliation(s)
- Gokce-Soganci Unsal
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Yildirim Beyazit University, Ankara, Turkey
| | - Ilser Turkyilmaz
- Clinical Associate Professor, New York University College of Dentistry, Department of Prosthodontics, New York, NY, USA
| | - Samantha Lakhia
- Third-year Dental Student, New York University College of Dentistry, New York, NY, USA
| |
Collapse
|
11
|
Schnutenhaus S, Gröller S, Luthardt RG, Rudolph H. Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study. Clin Implant Dent Relat Res 2018; 20:541-549. [PMID: 29691987 DOI: 10.1111/cid.12614] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2017] [Revised: 01/27/2018] [Accepted: 03/17/2018] [Indexed: 11/26/2022]
Abstract
BACKGROUND Template-guided implant placement is a method for optimal implant positioning from a prosthetic and surgical viewpoint. The treatment planning is based on three-dimensional X-ray data and model scan data, as well as on prosthetic planning (set-up). These data are matched (superimposed) with the aid of an X-ray template or by manual matching without special referencing. PURPOSE The objective of this prospective controlled clinical study was to determine and compare the accuracy of the match with and without an additional X-ray template. MATERIALS AND METHODS The DICOM data of the cone beam computed tomography (CBCT) were converted into surface data sets and then superimposed on model scan data using three different methods (manually, based on an X-ray template, or semi-automatically with computer assistance). The mean deviations between these results of these matching methods were investigated. RESULTS The procedures achieved a matching accuracy of 0.2 mm on average. This corresponds to the resolution of the CBCT (0.2 voxels). Further studies are necessary to verify the procedure even for patients with few (0-4) residual teeth. CONCLUSION In the presence of a sufficient number of residual teeth, the manual matching of model scan data with CBCT data is sufficiently accurate for implant planning and template-guided implementation. The results of the present study suggest that X-ray templates can be dispensed with saving the patient a substantial amount of time and money.
Collapse
Affiliation(s)
- Sigmar Schnutenhaus
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Sebastian Gröller
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Ralph G Luthardt
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| | - Heike Rudolph
- Department of Prosthetic Dentistry, Center of Dentistry, University of Ulm, Germany and Private practice, Hilzingen, Germany
| |
Collapse
|
12
|
Schnutenhaus S, Edelmann C, Rudolph H, Dreyhaupt J, Luthardt RG. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study. Clin Oral Investig 2018; 22:2363-2372. [DOI: 10.1007/s00784-018-2339-8] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Accepted: 01/08/2018] [Indexed: 10/18/2022]
|