1
|
Abstract
Renal insufficiency is a risk factor for mortality and morbidity during endovascular aneurysm repair. Multiple changes in practice have occurred to mitigate renal injury and renal dysfunction. Transrenal fixation does carry an increased risk of a decline in renal function in the medium term. Renal stenting for athero-occlusive disease during endovascular aneurysm repair needs careful consideration, as indications have changed and there are unexpected consequences with early vessel occlusion. The growing number of renal interventions during complex endovascular aneurysm repair with the advent of chimney snorkel/periscope techniques and the introduction of fenestrated grafts has shown the resilience of the intervention with relatively low renal issues (approximately 10%), but has also illustrated the need for additional device development.
Collapse
Affiliation(s)
- Mark G Davies
- Vascular and Endovascular Surgery, Department of Cardiovascular Surgery, Houston Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, 6550 Fannin, Smith Tower, Suite 1401, Houston, TX 77030.
| |
Collapse
|
2
|
Berger L, Palcau L, Gouicem D, Coffin O. Persistent type B aortic dissection treatment by renal artery reentry stent grafting as an alternative to open surgery. Ann Vasc Surg 2013; 27:498.e5-8. [PMID: 23545093 DOI: 10.1016/j.avsg.2012.08.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2012] [Revised: 08/13/2012] [Accepted: 08/27/2012] [Indexed: 10/27/2022]
Abstract
Type B aortic dissections complicated by pain, malperfusion, or aneurysm expansion mandate surgical intervention. Success of this therapy is predicated on exclusion and thrombosis of the false lumen of the aneurysm. This report presents a case in which cessation of flow was achieved using a covered stent graft to close a renal reentry tear after a previous closing and overstenting of the main tear. This approach may provide a helpful adjunct to the endovascular treatment of complicated type B aortic dissections.
Collapse
|
3
|
Haemodynamic analysis of the effect of different types of plaques in the left coronary artery. Comput Med Imaging Graph 2013; 37:197-206. [DOI: 10.1016/j.compmedimag.2013.02.001] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2012] [Revised: 01/08/2013] [Accepted: 02/27/2013] [Indexed: 11/18/2022]
|
4
|
Sun Z. evidence for contrast-enhanced ultrasound in fenestrated EVAR surveillance. J Endovasc Ther 2013; 19:656-60. [PMID: 23046332 DOI: 10.1583/jevt-12-3909c.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Australia.
| |
Collapse
|
5
|
Chaichana T, Sun Z, Jewkes J. Hemodynamic impacts of various types of stenosis in the left coronary artery bifurcation: a patient-specific analysis. Phys Med 2013; 29:447-52. [PMID: 23453845 DOI: 10.1016/j.ejmp.2013.02.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2012] [Revised: 02/06/2013] [Accepted: 02/11/2013] [Indexed: 12/18/2022] Open
Abstract
This study investigates the hemodynamic changes to various types of coronary stenosis in the left coronary artery bifurcation, based on a patient-specific analysis. Twenty two patients with left coronary artery disease were included in this study. All stenoses involving the left coronary artery bifurcation were classified into four types, according to their locations: A) left circumflex (LCx) and left anterior descending (LAD), B) LCx only, C) left main stem only, and D) LAD only. Computational fluid dynamics (CFD) was performed to analyze the flow and wall shear stress (WSS) changes in all reconstructed left coronary geometries. Our results showed that the flow velocity and WSS were significantly increased at stenotic locations. High WSS was found at >70% lumen stenosis, which ranged from 2.5 Pa to 3.5 Pa. This study demonstrates that in patients with more than 50% stenosis in the left coronary artery bifurcation, WSS plays an important role in providing information about the extent of coronary atherosclerosis in the left coronary artery branch.
Collapse
Affiliation(s)
- Thanapong Chaichana
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, GPO Box, U1987, Perth, Western Australia 6845, Australia.
| | | | | |
Collapse
|
6
|
Abdominal aortic aneurysm: Treatment options, image visualizations and follow-up procedures. J Geriatr Cardiol 2012; 9:49-60. [PMID: 22783323 PMCID: PMC3390098 DOI: 10.3724/sp.j.1263.2012.00049] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2011] [Revised: 10/19/2011] [Accepted: 10/26/2011] [Indexed: 11/25/2022] Open
Abstract
Abdominal aortic aneurysm is a common vascular disease that affects elderly population. Open surgical repair is regarded as the gold standard technique for treatment of abdominal aortic aneurysm, however, endovascular aneurysm repair has rapidly expanded since its first introduction in 1990s. As a less invasive technique, endovascular aneurysm repair has been confirmed to be an effective alternative to open surgical repair, especially in patients with co-morbid conditions. Computed tomography (CT) angiography is currently the preferred imaging modality for both preoperative planning and post-operative follow-up. 2D CT images are complemented by a number of 3D reconstructions which enhance the diagnostic applications of CT angiography in both planning and follow-up of endovascular repair. CT has the disadvantage of high cummulative radiation dose, of particular concern in younger patients, since patients require regular imaging follow-ups after endovascular repair, thus, exposing patients to repeated radiation exposure for life. There is a trend to change from CT to ultrasound surveillance of endovascular aneurysm repair. Medical image visualizations demonstrate excellent morphological assessment of aneurysm and stent-grafts, but fail to provide hemodynamic changes caused by the complex stent-graft device that is implanted into the aorta. This article reviews the treatment options of abdominal aortic aneurysm, various image visualization tools, and follow-up procedures with use of different modalities including both imaging and computational fluid dynamics methods. Future directions to improve treatment outcomes in the follow-up of endovascular aneurysm repair are outlined.
Collapse
|
7
|
Chaichana T, Sun Z, Jewkes J. Impact of plaques in the left coronary artery on wall shear stress and pressure gradient in coronary side branches. Comput Methods Biomech Biomed Engin 2012; 17:108-18. [PMID: 22443493 DOI: 10.1080/10255842.2012.671308] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
In this study, we investigate plaques located at the left coronary bifurcation. We focus on the effect that the resulting changes in wall shear stress (WSS) and wall pressure stress gradient (WPSG) have on atherosclerotic progress in coronary artery disease. Coronary plaques were simulated and placed at the left main stem and the left anterior descending to produce >50% narrowing of the coronary lumen. Computational fluid dynamics analysis was carried out, simulating realistic physiological conditions that show the in vivo cardiac haemodynamic. WSS and WPSG in the left coronary artery were calculated and compared in the left coronary models, with and without the presence of plaques during cardiac cycles. Our results showed that WSS decreased while WPSG was increased in coronary side branches due to the presence of plaques. There is a direct correlation between coronary plaques and subsequent WSS and WPSG variations based on the bifurcation plaques simulated in the realistic coronary models.
Collapse
Affiliation(s)
- Thanapong Chaichana
- a Discipline of Medical Imaging, Department of Imaging and Applied Physics , Curtin University , Perth WA 6845 , Australia
| | | | | |
Collapse
|
8
|
Computational fluid dynamics analysis of the effect of plaques in the left coronary artery. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2012; 2012:504367. [PMID: 22400051 PMCID: PMC3287085 DOI: 10.1155/2012/504367] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2011] [Revised: 11/08/2011] [Accepted: 11/09/2011] [Indexed: 12/02/2022]
Abstract
This study was to investigate the hemodynamic effect of simulated plaques in left coronary artery models, which were generated from a sample patient's data. Plaques were simulated and placed at the left main stem and the left anterior descending (LAD) to produce at least 60% coronary stenosis. Computational fluid dynamics analysis was performed to simulate realistic physiological conditions that reflect the in vivo cardiac hemodynamics, and comparison of wall shear stress (WSS) between Newtonian and non-Newtonian fluid models was performed. The pressure gradient (PSG) and flow velocities in the left coronary artery were measured and compared in the left coronary models with and without presence of plaques during cardiac cycle. Our results showed that the highest PSG was observed in stenotic regions caused by the plaques. Low flow velocity areas were found at postplaque locations in the left circumflex, LAD, and bifurcation. WSS at the stenotic locations was similar between the non-Newtonian and Newtonian models although some more details were observed with non-Newtonian model. There is a direct correlation between coronary plaques and subsequent hemodynamic changes, based on the simulation of plaques in the realistic coronary models.
Collapse
|
9
|
Sun Z. Multislice computed tomography angiography in the diagnosis of cardiovascular disease: 3D visualizations. Front Med 2011; 5:254-70. [DOI: 10.1007/s11684-011-0153-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Accepted: 08/11/2011] [Indexed: 10/17/2022]
|
10
|
Chaichana T, Sun Z, Jewkes J. Computation of hemodynamics in the left coronary artery with variable angulations. J Biomech 2011; 44:1869-78. [PMID: 21550611 DOI: 10.1016/j.jbiomech.2011.04.033] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2010] [Revised: 04/15/2011] [Accepted: 04/16/2011] [Indexed: 12/18/2022]
Abstract
The purpose of this study was to investigate the hemodynamic effect of variations in the angulations of the left coronary artery, based on simulated and realistic coronary artery models. Twelve models consisting of four realistic and eight simulated coronary artery geometries were generated with the inclusion of left main stem, left anterior descending and left circumflex branches. The simulated models included various coronary artery angulations, namely, 15°, 30°, 45°, 60°, 75°, 90°, 105° and 120°. The realistic coronary angulations were based on selected patient's data with angles ranging from narrow angles of 58° and 73° to wide angles of 110° and 120°. Computational fluid dynamics analysis was performed to simulate realistic physiological conditions that reflect the in vivo cardiac hemodynamics. The wall shear stress, wall shear stress gradient, velocity flow patterns and wall pressure were measured in simulated and realistic models during the cardiac cycle. Our results showed that a disturbed flow pattern was observed in models with wider angulations, and wall pressure was found to reduce when the flow changed from the left main stem to the bifurcated regions, based on simulated and realistic models. A low wall shear stress gradient was demonstrated at left bifurcations with wide angles. There is a direct correlation between coronary angulations and subsequent hemodynamic changes, based on realistic and simulated models. Further studies based on patients with different severities of coronary artery disease are required to verify our results.
Collapse
Affiliation(s)
- Thanapong Chaichana
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, G.P.O Box U1987, Perth, Western Australia 6845, Australia
| | | | | |
Collapse
|
11
|
Aortic dissection: Identification of entry site with CT virtual intravascular endoscopy. Biomed Imaging Interv J 2010. [DOI: 10.2349/biij.6.3.e22] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
12
|
Almutairi AM, Sun Z, Ng C, Al-Safran ZA, Al-Mulla AA, Al-Jamaan AI. Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: An in vitro phantom study. Eur J Radiol 2010; 74:156-60. [DOI: 10.1016/j.ejrad.2009.01.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2008] [Revised: 01/15/2009] [Accepted: 01/21/2009] [Indexed: 10/21/2022]
|
13
|
CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting. Biomed Imaging Interv J 2009; 5:e22. [PMID: 21610990 PMCID: PMC3097715 DOI: 10.2349/biij.5.4.e22] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2009] [Revised: 07/02/2009] [Accepted: 07/15/2009] [Indexed: 11/17/2022] Open
Abstract
The aim of this case report is to present the additional value provided by CT virtual endoscopy and 3D stereoscopic visualisation when compared with 2D visualisations in the assessment of coronary stenting. A 64-year old patient was treated with left coronary stenting 8 years ago and recently followed up with multidetector row CT angiography. An in-stent restenosis of the left coronary artery was suspected based on 2D axial and multiplanar reformatted images. 3D virtual endoscopy was generated to demonstrate the smooth intraluminal surface of coronary artery wall, and there was no evidence of restenosis or intraluminal irregularity. Virtual fly-through of the coronary artery was produced to examine the entire length of the coronary artery with the aim of demonstrating the intraluminal changes following placement of the coronary stent. In addition, stereoscopic views were generated to show the relationship between coronary artery branches and the coronary stent. In comparison with traditional 2D visualisations, virtual endoscopy was useful for assessment of the intraluminal appearance of the coronary artery wall following coronary stent implantation, while stereoscopic visualisation improved observers’ understanding of the complex cardiac structures. Thus, both methods could be used as a complementary tool in cardiac imaging.
Collapse
|
14
|
Sun Z, Dimpudus FJ, Nugroho J, Adipranoto JD. CT virtual intravascular endoscopy assessment of coronary artery plaques: a preliminary study. Eur J Radiol 2009; 75:e112-9. [PMID: 19781885 DOI: 10.1016/j.ejrad.2009.09.007] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2009] [Revised: 06/17/2009] [Accepted: 09/03/2009] [Indexed: 01/10/2023]
Abstract
PURPOSE The purpose of this study was to investigate the potential value of CT virtual intravascular endoscopy (VIE) in the visualization and assessment of coronary plaques in patients suspected of coronary artery disease. MATERIALS AND METHODS 20 (13 men, 7 women, mean age 54 years) consecutive patients with suspected coronary artery disease undergoing 64-slice CT angiography were included in the study. Four main coronary artery branches were assessed with regard to the presence of coronary plaques based on 2D axial, multiplanar reformation, 3D volume rendering and VIE visualizations. The coronary plaques were characterized into calcified, noncalcified and mixed plaques. The intraluminal appearances of these coronary plaques were demonstrated with VIE images and correlated with 2D and 3D images to determine the diagnostic value of VIE for the assessment of the plaques. RESULTS VIE was able to identify and demonstrate the intraluminal appearances of coronary plaques in 18 patients involving 32 coronary artery branches which were shown as an irregularly intraluminal protruding sign in extensively calcified plaques and smooth protruding appearance in noncalcified or focally calcified plaques. An irregular intraluminal appearance was also noticed in the presence of mixed plaques due to variable components with different CT attenuations contained within the plaques. VIE accurately confirmed the degree of coronary stenosis or occlusion despite the presence of heavy calcification. CONCLUSION VIE could be used as a complementary tool to conventional CT visualizations for the analysis of luminal changes and assessment of disease extent caused by the coronary plaques.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, GPO Box, U1987, Perth 6845, Australia.
| | | | | | | |
Collapse
|
15
|
Helical CT angiography of fenestrated stent grafting of abdominal aortic aneurysms. Biomed Imaging Interv J 2009; 5:e3. [PMID: 21611029 PMCID: PMC3097760 DOI: 10.2349/biij.5.2.e3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2008] [Accepted: 03/04/2009] [Indexed: 11/17/2022] Open
Abstract
Fenestrated stent grafts have been developed to treat patients with abdominal aortic aneurysms (AAA) associated with complicated aneurysm necks, such as short necks, severe angulated or poor quality necks (presence of calcification or thrombus). The technique is performed by creating an opening in the graft material so that the stent graft can be placed above the renal and other visceral branches without compromising blood perfusion to these vessels. In most situations, a supporting stent is inserted into the fenestrated vessel to provide fixation of the fenestrated vessel against stent grafts, as well as to preserve patency of the vessel. Helical CT angiography (CTA) is the preferred imaging modality in both pre-operative planning and post-procedural follow-up of fenestrated repair of AAA. The main concerns of fenestrated stent grafting lie in the following two aspects: patency of the fenestrated vessels and position of the fenestrated stents in relation to the artery branches. In this article, the author presents the clinical applications of 2D and 3D visualizations in the follow-up of patients with AAA treated with fenestrated stent grafts, with the aim of providing useful information to readers and increasing their knowledge of an increasingly used technique, fenestrated stent grafting in the treatment of AAA.
Collapse
|
16
|
Multislice CT angiography in abdominal aortic aneurysm treated with endovascular stent grafts: evaluation of 2D and 3D visualisations. Biomed Imaging Interv J 2007; 3:e20. [PMID: 21614294 PMCID: PMC3097683 DOI: 10.2349/biij.3.4.e20] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2006] [Revised: 11/13/2006] [Accepted: 05/09/2007] [Indexed: 12/02/2022] Open
Abstract
Endovascular repair of abdominal aortic aneurysms has been introduced into the clinical practice for more than a decade and has been confirmed to be an effective alternative to conventional open surgery, especially in patients with co-morbid medical conditions. Helical CT angiography is the preferred imaging method in the follow-up of endovascular repair. Recent introduction of multislice CT scanners has augmented its diagnostic role in this area. Diagnostic value of multlislice CT has been complemented by a series of 3D post-processings, which assist vascular surgeons in accurately assessing the effect of endovascular repair by providing additional information when compared to conventional 2D axial images. These reconstructions include multiplanar reformation, curved multiplanar reconstruction, shaded surface display, maximum intensity projection, volume rendering and virtual endoscopy. This article aims to demonstrate the generation of these 2D/3D reconstructions based on multislice CT data acquired from a group of patients with abdominal aortic aneurysm following endovascular repair. A brief introduction of generating each reconstruction was provided; potential clinical applications of each reconstruction were briefly discussed. Images were presented in a dynamic format with the aim of allowing the reader to easily understand the post-processing of these reconstructions.
Collapse
|
17
|
Sun Z. Multislice CT angiography in aortic stent grafting: Relationship between image noise and body mass index. Eur J Radiol 2007; 61:534-40. [PMID: 17092681 DOI: 10.1016/j.ejrad.2006.10.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2006] [Revised: 10/11/2006] [Accepted: 10/11/2006] [Indexed: 11/18/2022]
Abstract
PURPOSE To investigate the correlation between image noise and body mass index (BMI) in multislice CT angiography (MSCT) for patients with abdominal aortic aneurysm (AAA) treated with endovascular stent grafts. MATERIALS AND METHODS Seventeen patients who underwent MSCT following endovascular repair of AAA were included in the study. Image noise (standard deviation of the CT attenuation: S.D.) and signal to noise ratio (SNR) were plotted against BMI to demonstrate the correlation using a linear regression method. Image quality of 3D reconstructions was correlated to the SNR and BMI. RESULTS The r-value of linear regression between S.D. and BMI was 0.578 (p<0.05), 0.835 and 0.802 (p<0.001), respectively, at the level of renal artery, aortic aneurysm and common iliac artery. The r-value of linear regression between SNR and BMI was 0.332, 0.516 and 0.552 (p<0.05), respectively, at above three levels. Image quality of 3D reconstructions was compromised in five patients and diagnosis was affected in two patients with BMI more than 30. CONCLUSION A significant correlation was observed between image noise and BMI in MSCT angiography of endovascular repair of AAA. Our findings are valuable for optimisation of MSCT angiography scanning protocols and reduction of radiation dose in MSCT examinations.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, GPO Box U1987, Perth, Western Australia 6845, Australia.
| |
Collapse
|
18
|
Sun Z, Stevenson G. Transrenal Fixation of Aortic Stent-Grafts: Short- to Midterm Effects on Renal Function—A Systematic Review. Radiology 2006; 240:65-72. [PMID: 16720868 DOI: 10.1148/radiol.2401050134] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To perform a systematic review of the short- to midterm effects of transrenal fixation of aortic stent-grafts on renal function in patients with abdominal aortic aneurysms. MATERIALS AND METHODS A search of the PubMed, MEDLINE, and EMBASE databases for English-language literature was performed. Studies with at least 10 patients were included for data analysis. Only studies on transrenal fixation of aortic stent-grafts that included follow-up results for renal function were included. A log-linear model was used for meta-analysis to compare transrenal fixation with infrarenal fixation. RESULTS Twenty-two studies met the inclusion criteria. Because two studies analyzed the same group of patients, one was excluded, for a total of 21 studies. Comparisons between transrenal fixation and infrarenal fixation were found in seven studies. For transrenal versus infrarenal fixation, the combined odds ratio, 95% confidence interval, and P value were found to be statistically significant with respect to postprocedural renal infarction only (combined odds ratio, 5.189; 95% confidence interval: 3.198, 8.420; P < .001). No significant difference was found between transrenal and infrarenal fixation with respect to renal dysfunction, renal artery occlusion, or endoleaks (P > .05). CONCLUSION Transrenal fixation of aortic stent-grafts seems to be a relatively safe alternative compared with infrarenal fixation in terms of short- to midterm follow-up. Postprocedural renal infarction, however, was significantly higher for transrenal fixation.
Collapse
Affiliation(s)
- Zhonghua Sun
- School of Health Sciences, University of Ulster, Newtownabbey, Northern Ireland, UK.
| | | |
Collapse
|
19
|
Sun Z. Three-dimensional visualization of suprarenal aortic stent-grafts: evaluation of migration in midterm follow-up. J Endovasc Ther 2006; 13:85-93. [PMID: 16445328 DOI: 10.1583/05-1648.1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To investigate the midterm results of transrenal fixation of abdominal aortic stent-grafts with regard to device migration and encroachment of stent wires on the renal and visceral branches. METHODS Imaging data from 18 patients (15 men; mean age 75 years, range 63-84) undergoing transrenal stent-graft fixation for abdominal aortic aneurysm (AAA) were included in the study. Computed tomographic angiographic data acquired within 1 week of stent-graft implantation were compared to the latest follow-up images. Postprocessing methods generated 3-dimensional (3D) maximum intensity projections (MIP) and virtual intravascular endoscopy (VIE) for evaluation of the relationship between suprarenal stents and aortic branches. Aortic neck angulation was measured in each patient for correlation with the incidence of stent migration. RESULTS The mean follow-up period was 40 months. 3D image visualizations showed that the stent-graft moved caudally in all patients (range 2.6-14.2 mm), with migration (>10 mm) observed in 4 (22%) patients. Corresponding VIE images documented changes in stent wire encroachment on the aortic branch ostia in 11 patients, including the number and position of crossing stent wires. There was no close relationship between aortic neck angulation and stent migration. CONCLUSION The current study demonstrated that migration occurs at midterm follow-up in transrenally deployed stent-grafts. 3D images were valuable for the assessment of stent migration, as well as its relationship with aortic branch ostia. Long-term follow-up of transrenal fixation deserves to be investigated, especially after observing stent migration relative to aortic ostial encroachment.
Collapse
Affiliation(s)
- Zhonghua Sun
- Department of Medical Imaging Science, Curtin University of Technology, Perth, Western Australia.
| |
Collapse
|
20
|
Sun Z, Ferris C. Optimal scanning protocol of multislice CT virtual intravascular endoscopy in pre-aortic stent grafting: In vitro phantom study. Eur J Radiol 2006; 58:310-6. [PMID: 16413983 DOI: 10.1016/j.ejrad.2005.11.034] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2005] [Revised: 11/04/2005] [Accepted: 11/28/2005] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To investigate the optimal scanning protocol for multislice computed tomography angiography (MSCT) in pre-aortic stent grafting observed with virtual intravascular endoscopy (VIE). MATERIALS AND METHODS The study was performed on a human abdominal aortic phantom which was housed in a perspex container, filled with contrast medium having CT attenuation similar to that used in the patient's abdominal CT scan. A series of scans were performed on a four-slice multislice CT scanner with the scanning protocols as follows: section thickness of 1.3, 3.2 and 6.5 mm, pitch value of 0.875, 1.25 and 1.75 with reconstruction intervals of 50% overlap. The degree of stair-step artifacts was measured at three different locations, superior mesenteric artery (SMA), renal ostium and the normal abdominal aorta. Standard deviation (S.D.) of the signal intensity measured on surface shaded images was used to determine the image quality. Radiation dose was also recorded in each scanning protocol. RESULTS The VIE images showed that image quality was not dependent on pitch and section thickness in the visualization of renal ostium and SMA, whereas it was dependent on these two factors at the level of the normal aorta (p<0.05). It was noticed that when section thickness reached 6.5 mm the SMA and renal ostia became distorted. Radiation dose measured in 1.3 mm protocols was significantly higher that those measured in other section thicknesses (p<0.05). CONCLUSION The scanning protocol of section thickness 3.2 mm, pitch 1.25 with a reconstruction interval of 1.6 mm was recommended as it allows optimal visualization of VIE images of aortic ostia, generation of fewer artifacts and less radiation dose.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, GPO Box U 1987, Perth, WA 6845, Australia.
| | | |
Collapse
|
21
|
Sun Z. Transrenal fixation of aortic stent-grafts: current status and future directions. J Endovasc Ther 2005; 11:539-49. [PMID: 15482027 DOI: 10.1583/04-1212.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Aortic stent-graft repair has been widely used in clinical practice for more than a decade, achieving satisfactory results compared to open surgical techniques. Transrenal fixation of stent-grafts is designed to obtain secure fixation of the proximal end of the stent-graft to avoid graft migration and to prevent type I endoleak. Unlike infrarenal deployment of stent-grafts, transrenal fixation takes advantage of the relative stability of the suprarenal aorta as a landing zone for the uncovered struts of the proximal stent. These transostial wires have sparked concern about the patency of the renal arteries, interference with renal blood flow, and effects on renal function. Although short to midterm results with suprarenal stent-grafts have not shown significant changes in renal function, long-term effects of this technique are still not fully understood. This review will explore the current status of transrenal fixation of aortic stent-grafts, potential risks of stent struts relative to the renal ostium, alternative methods to preserve blood flow to the renal arteries, and future directions or developments in stent-graft design to prevent myointimal proliferation around the stent struts.
Collapse
Affiliation(s)
- Zhonghua Sun
- School of Applied Medical Sciences and Sports Studies, University of Ulster, Newtownabbey, Northern Ireland, UK.
| |
Collapse
|
22
|
Sun Z, Gallagher E. Multislice CT Virtual Intravascular Endoscopy for Abdominal Aortic Aneurysm Stent Grafts. J Vasc Interv Radiol 2004; 15:961-70. [PMID: 15361564 DOI: 10.1097/01.rvi.0000140936.45313.ee] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the optimal scanning protocols of multislice computed tomographic (CT) angiography in aortic stent graft placement observed on virtual intravascular endoscopy (VIE). MATERIALS AND METHODS A human aorta phantom was built with a commercial aortic stent graft placed in situ. The phantom was housed in a perspex container and filled with contrast medium with CT attenuation similar to that used in the patient's abdominal scanning. CT was performed with a four-slice multislice CT scanner with section thickness of 1.3 mm, 2 mm, and 3.2 mm, pitch of 0.75, 1, and 1.5, and reconstruction interval of 50% overlap and no overlap. Stair-step artifacts were quantified by measuring the SD of signal intensity on surfaced shaded VIE images in three different locations: superior mesenteric artery (SMA), renal ostium, and aortic aneurysm. RESULTS Image quality of VIE images was independent of section thickness and pitch values in the level of renal ostium and aortic aneurysm (P >.05), whereas it was determined by the section thickness and pitch in the level of SMA (P <.05). Aortic branch origin became irregular or distorted when section thickness increased to 3.2 mm or pitch reached 1.5. CONCLUSION A scanning protocol of section thickness of 2 mm, pitch 1, and reconstruction interval of 1 mm is recommended in aortic stent graft placement because it allows fewer stair-step artifacts and better visualization of the aortic stent wires observed on VIE.
Collapse
Affiliation(s)
- Zhonghua Sun
- School of Applied Medical Sciences and Sports Studies, University of Ulster, Shore Road, Newtownabbey, BT37 0QB, Northern Ireland, United Kingdom.
| | | |
Collapse
|
23
|
|