Benalcazar-Jalkh EB, Cunha VS, Bergamo ETP, Alves LMM, de Monteiro-Sousa RS, Campos TMB, Tanaka R, Marcolino GDA, Souza FMD, Bonfante EA. Finishing technique effect on strength of zirconia-reinforced lithium silicate ceramic. Eur J Oral Sci 2024; 132:e12964. [PMID: 38062529 DOI: 10.1111/eos.12964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Accepted: 11/14/2023] [Indexed: 01/25/2024]
Abstract
The aim of this study was to evaluate the effect of two finishing techniques, glazing or polishing, in comparison with the as-cut condition, on the biaxial-flexural-strength (BFS) of a zirconia-reinforced lithium silicate ceramic (ZLS). Cylinders were milled from CAD/CAM blocks and sliced to obtain disc-shaped specimens (ISO6872:2015). Polished and glazed specimens were processed following the manufacturer's instructions. Thirty-three specimens were obtained for each condition and microstructural and BFS/fractographic characterizations were performed. BFS and roughness data were analyzed using Weibull statistics and ANOVA one-way with Tukey post-hoc test, respectively. While a rougher surface was observed for as-cut specimens, smoother surfaces were observed for polished and glazed ZLS at microscopical evaluation and confirmed through surface-roughness evaluation. X-ray spectra depicted a glass phase for all groups and characteristic metasilicate, lithium disilicate, and lithium phosphate peaks for the as-cut and polished specimens. Glazed specimens showed higher characteristic strength than polished and as-cut specimens, which did not differ significantly. While higher Weibull-modulus was observed for the polished than for the as-cut specimens, no statistically significant differences were noted between glazed and polished, and between glazed and as-cut specimens. ZLS presents higher strength when glazed, and polishing increases the structural reliability of the material relative to the as-cut condition. Both finishing techniques reduced surface roughness similarly.
Collapse
Affiliation(s)
| | - Verena Souza Cunha
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Edmara Tatiely Pedroso Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
- Biomaterials Division, NYU Dentistry, New York, USA
- Department of Prosthodontics, NYU Dentistry, New York, USA
| | - Larissa Marcia Martins Alves
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | | | - Tiago Moreira Bastos Campos
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | | | - Giovana de Assis Marcolino
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Felipe Machado de Souza
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Sao Paulo, Brazil
| |
Collapse
|
2
|
Gimenez-Gonzalez B, Setyo C, Picaza MG, Tribst JPM. Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool. Heliyon 2022; 8:e12103. [PMID: 36561666 PMCID: PMC9763733 DOI: 10.1016/j.heliyon.2022.e12103] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 10/22/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose To assess the influence of defect size and tooth anatomy on the measurements performed by a 3D patient monitoring tool. Methods A fully dentate model was scanned to obtain a master digital file. Virtual duplicates received defects created in molars (16, 18, 28) and incisors (11, 12, 22), according to different depths (60, 80, 120 microns) and sizes (small, medium, large) totaling 180 conditions. The surface changes measured by the 3D Patient Monitoring Tool (3Shape TRIOS Patient Monitoring [TPM]) were compared with the reference by 2 calibrated operators. False Positives (FP), and False Negatives (FN) defect were registered. Pearson chi-square test, Multivariate binary logistic regression and Spearman rank correlation were used to evaluate the data (α = 0.05). Results A significant association was found between the area and the presence of FP and FN (P < .01). Larger defects had higher chances to present FP or an FN respectively. There was a significant association between the tooth and the presence of a FP value (FP, P = .02; FN, P = .005) specially in molars. No significant association was found between the defect depth and the presence of a FP value. Spearman rank correlation showed a strong association between the presence of an FP and an FN (r = 0.858, P < .01). Conclusions The defect size and tooth anatomy significantly affected the virtual follow-up, whereas defect depth did not. Small defects were correctly detected in all cases. An incorrect measurement on one side of the tooth simultaneously resulted in incorrect measurement on the opposite side. Clinical relevance The clinician should be aware that different factors related to the characteristics of the defects could affect the quality of the full-arch digital follow-up. Therefore, caution is needed when interpreting the models comparison in cases that a larger area of a tooth has been modified.
Collapse
Affiliation(s)
- Beatriz Gimenez-Gonzalez
- Department of Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, the Netherlands
| | - Christof Setyo
- Department of Implantology and Prosthetic Dentistry, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, the Netherlands
| | - Mikel Gomez Picaza
- Createch Medical, Polígono Kurutz-Gain Pabellón, 3B 20850 Mendaro, Spain
| | - João Paulo Mendes Tribst
- Department of Oral Regenarative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit Amsterdam, 1081 LA Amsterdam, the Netherlands,Corresponding author.
| |
Collapse
|
3
|
Alves LMM, Rodrigues CDS, Ramos NDC, Buizastrow J, Campos TMB, Bottino MA, Zhang Y, Melo RMD. Silica infiltration on translucent zirconia restorations: Effects on the antagonist wear and survivability. Dent Mater 2022; 38:2084-2095. [PMID: 36446649 PMCID: PMC9928576 DOI: 10.1016/j.dental.2022.11.015] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 09/23/2022] [Accepted: 11/11/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To assess potential antagonist wear and survival probability of silica-infiltrated zirconia compared to glass-graded, glazed, and polished zirconia. METHODS Table top restorations made of 3Y-TZP (3Y), 5Y-PSZ (5Y), and lithium disilicate (LD) were bonded onto epoxy resin preparations. Each zirconia was divided into five groups according to the surface treatment: polishing; glaze; polishing-glaze; glass infiltration; and silica infiltration. The LD restorations received a glaze layer. Specimens were subjected to sliding fatigue wear using a steatite antagonist (1.25 ×106 cycles, 200 N). The presence of cracks, fractures, and/or debonding was checked every one/third of the total number of cycles was completed. Roughness, microstructural, Scanning electron microscopy, wear and residual stress analyses were conducted. Kaplan-Meier, Mantel-Cox (log-rank) and ANOVA tests were performed for statistical analyses. RESULTS The survival probability was different among the groups. Silica infiltration and polishing-glaze led to lower volume loss than glaze and glass-infiltration. Difference was observed for roughness among the zirconia and surface treatment, while lithium disilicate presented similar roughness compared to both glazed zirconia. Scanning electron microscopy revealed the removal of the surface treatment after sliding fatigue wear in all groups. Compressive stress was detected on 3Y surfaces, while tensile stress was observed on 5Y. SIGNIFICANCE 3Y and 5Y zirconia behaved similarly regarding antagonist wear, presenting higher antagonist wear than the glass ceramic. Silica-infiltrated and polished-glazed zirconia produced lower antagonist volume loss than glazed and glass-infiltrated zirconia. Silica-infiltrated 3Y and lithium disilicate restorations were the only groups to show survival probabilities lower than 85%.
Collapse
Affiliation(s)
- Larissa Marcia Martins Alves
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Camila da Silva Rodrigues
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil; Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Nathalia de Carvalho Ramos
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Jeff Buizastrow
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 1st Ave., New York, NY 10010, United States
| | - Tiago Moreira Bastos Campos
- Department of Physics, Aeronautics Technological Institute (ITA), Praça Marechal Eduardo Gomes, 50, 12228-900 São José dos Campos, SP, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil
| | - Yu Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, PA 19104, United States
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, São Paulo State University (Unesp), Institute of Science and Technology, Av. Eng. Francisco José Longo, 777, Jardim São Dimas, 12245-000 São José dos Campos, SP, Brazil.
| |
Collapse
|
4
|
Salem BO, Elshehawi DM, Elnaggar GA. Fracture resistance of pressed ZLS crowns versus pressed LD crowns under thermo-mechanical cycling. Braz Dent J 2022; 33:103-109. [PMID: 36477957 PMCID: PMC9733374 DOI: 10.1590/0103-6440202204993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 10/13/2022] [Indexed: 12/12/2022] Open
Abstract
The aim of this study was conducted to assess the fracture resistance of zirconia reinforced lithium silicate all ceramic material "Celtra Press" compared to lithium disilicate one "IPS e-max Press" under simulated oral conditions. Fourteen ceramic crowns were fabricated on epoxy dies which were duplicated from stainless steel master die and divided into two equal groups (n=7) according to the material of construction; Group A: Crowns fabricated with IPS e-max Press material and Group B: Crowns fabricated with Celtra Press material. The crowns were then cemented onto their corresponding dies with a self-adhesive resin cement and subjected to thermocycling and cyclic loading. Then they were loaded to fractur in a universal testing machine. The results were tabulated and statistically analyzed using Kolmogorov-Smirnov and Shapiro-Wilk tests. Student t-test used to compare mean values. The significance level was set at P ≤ 0.05 and 95% Confidence interval. Statistical analysis was performed using Graph Pad Instat (Graph Pad, Inc.) software for windows. The mean ± SD values of fracture resistance were recorded for lithium Disilicate group (1706.01 ±154.32 N) meanwhile the mean ± SD value recorded with celtra group were (1550.67±196.71 N). Zirconia reinforced lithium silicate ceramic crowns produced comparable fracture resistance values to lithium disilicate ceramic crowns and both tested materials are within the clinically acceptable values in the posterior area.
Collapse
Affiliation(s)
- Basma Osama Salem
- Faculty of dentistry, Cairo university, department of fixed prosthodontics, Giza, Egypt
| | - Dina Magdy Elshehawi
- Faculty of dentistry, Cairo university, department of fixed prosthodontics, Giza, Egypt
| | | |
Collapse
|
5
|
Bueno MG, Tribst JPM, Borges ALS. Canine guidance reconstruction with ceramic or composite resin: A 3D finite element analysis and in vitro wear study. J Prosthet Dent 2022; 127:765.e1-765.e9. [DOI: 10.1016/j.prosdent.2022.01.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 01/10/2022] [Accepted: 01/10/2022] [Indexed: 11/28/2022]
|
6
|
Microstructural development during crystallization firing of a dental-grade nanostructured lithia-zirconia glass-ceramic. Ann Ital Chir 2021. [DOI: 10.1016/j.jeurceramsoc.2021.04.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
7
|
Optical behaviors, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate (ZLS): A narrative review. J Dent 2021; 112:103722. [PMID: 34118284 DOI: 10.1016/j.jdent.2021.103722] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 05/28/2021] [Accepted: 06/01/2021] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVES The present narrative review was focused on the optical properties, surface treatment, adhesion, and clinical indications of zirconia-reinforced lithium silicate ceramics (ZLS) for Computer-aided design / Computer-aided manufacturing (CAD/CAM) technologies. DATA/SOURCES A literature search was performed by 3 calibrated independent researchers on PubMed, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The criteria for inclusion were: 1) papers addressing at least one of the following variables about ZLS: optical properties, surface treatment, adhesion, and clinical indications; 2) in vitro, in silico, or in vivo studies; 3) case reports; 4) systematic reviews. The exclusion criteria were: 1) animal studies; 2) non-dental studies; 3) studies only focusing on ZLS used in the heat-pressed process. STUDY SELECTION 98 records among in vitro studies and case reports were included. CONCLUSIONS Despite the promising microstructure characteristics of ZLS, increased translucency compared to lithium disilicate ceramics (LS2) was not proven, but acceptable color changes and stability were reported. Mechanical polishing was the most effective method to reduce surface roughness. Moreover, machinability and handling of ZLS resulted harder than LS2. Conventional acid etching procedures seemed effective in conditioning ZLS surface, but no protocol has been established yet. Besides, silane-coupling and dual-curing resin cements were recommended. CLINICAL SIGNIFICANCE ZLSs can be used for anterior and posterior fixed single-unit CAD/CAM restorations onto both natural teeth and implants, but do not seem to represent a viable treatment option for endocrowns onto posterior teeth or fixed dental prostheses.
Collapse
|
8
|
Wille S, Sieper K, Kern M. Wear resistance of crowns made from different CAM/CAD materials. Dent Mater 2021; 37:e407-e413. [PMID: 33875248 DOI: 10.1016/j.dental.2021.03.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 02/26/2021] [Accepted: 03/29/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVES The aim of this laboratory study was to evaluate the wear resistance of crowns made from current computer-aided design and computer-aided manufacture (CAD/CAM) materials. In addition, the abrasion of the steatite antagonist against these materials was compared. METHODS Identically shaped crowns of lithium disilicate, zirconia-reinforced lithium disilicate and a polymer-infiltrated ceramic network (PICN) were fabricated with an occlusal thickness of 1.5mm and a lateral wall thickness of 1.2mm (n=8). The crowns were cemented with a dual-polymerizing luting resin on composite resin dies. Using spherical steatite antagonists, all specimens were loaded with 49N for 1,200,000 cycles in a mastication simulator with additional thermocycling. After 120,000, 240,000, 480,000, 960,000, and 1,200,000 cycles, precision impressions were made and investigated with a laser scanning microscope. The vertical and volume substance loss was measured. Additionally, the substance loss of the antagonists was evaluated after 1,200,000 loading cycles. RESULTS No significant difference (p>0.05) was found in the median volume loss of the test materials after 1,200,000 cycles (lithium disilicate: 0.405mm3, PICN: 0.362mm3, zirconia-reinforced lithium disilicate: 0.340mm3). The vertical substance loss of PICN (157μm) was significantly lower (p≤0.05) than that of lithium disilicate (201μm) and zirconia reinforced lithium disilicate (191μm). However, the substance loss of steatite against zirconia-reinforced lithium disilicate (0.191mm3) was significantly lower (p≤0.05) than against lithium disilicate (0.296mm3) and PICN (0.531mm3). SIGNIFICANCE All three CAD/CAM materials showed wear resistance that seems appropriate for clinical application. Also, the abrasion of the antagonist looks promising.
Collapse
Affiliation(s)
- Sebastian Wille
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Kim Sieper
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| | - Matthias Kern
- Department of Prosthodontics, Propaedeutics and Dental Materials, School of Dentistry, Christian-Albrechts University at Kiel, Germany.
| |
Collapse
|
9
|
de Carvalho ABG, Dal Piva AMDO, Tribst JPM, Werner A, Saavedra GDSFA, Kleverlaan CJ. Effect of microwave crystallization on the wear resistance of reinforced glass-ceramics. J Mech Behav Biomed Mater 2020; 111:104009. [DOI: 10.1016/j.jmbbm.2020.104009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 07/16/2020] [Accepted: 07/21/2020] [Indexed: 10/23/2022]
|
10
|
Wang J, Ling Z, Zheng Z, Zheng C, Gai Y, Zeng Y, Zhu X, Chen L, Wu B, Yan W. Clinical efficacy of ceramic versus resin-based composite endocrowns in Chinese adults: study protocol for a randomized controlled trial. Trials 2020; 21:559. [PMID: 32571397 PMCID: PMC7310236 DOI: 10.1186/s13063-020-04506-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 06/12/2020] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Endocrown restoration is widely used to restore endodontically treated teeth. However, the clinical effects of different computer-aided design/computer-aided manufacturing (CAD/CAM) materials for endocrown restoration are not clear. The primary objective of this trial is to compare the clinical efficacy of resin-based bloc and ceramic endocrowns for restoring endodontically treated teeth. METHODS The proposed resin-based bloc and ceramic endocrown assessment trial is a parallel group-designed randomized controlled trial. We will recruit 156 adults between 18 and 75 years old with a minimum of one such molar. The inclusion criteria were good oral hygiene habits, root apex of molar without evident damage, receipt of standard endodontic treatment, need for endocrown restoration, and only one endocrown restoration performed per patient. Patients participating in another study or those with systemic diseases, disabilities, or known allergies to used materials will be excluded. All patients will be randomized and restored with resin-based bloc and ceramic endocrown according to a random number table. Clinical evaluations will be performed at baseline and after treatment at 6, 12, and 24 months, in accordance with the modified Federation Dentaire Internationale (FDI) criteria, by two independent evaluators. The primary outcome is marginal adaptation; secondary outcomes include wear, tooth integrity, fracture of material and retention, marginal staining, and patient view. All data will be analyzed by an independent statistician. Signed rank-sum tests will be used for intragroup comparisons. Wilcoxon rank-sum tests will be used for intergroup comparisons. Hierarchical logistic regression will be used to adjust the baseline and other important indicators. DISCUSSION This study will investigate endocrowns of two CAD/CAM materials for endodontically treated molars. The results may help clinicians choose the better CAD/CAM material option and explain to patients the advantages and disadvantages of these two materials with evidence-based support. For patients, the results may lead to improvement in long-term restoration. TRIAL REGISTRATION ClinicalTrials.gov NCT04033380. Registered on 24 July 2019.
Collapse
Affiliation(s)
- Jilei Wang
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Zhiting Ling
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Ziting Zheng
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Chunqing Zheng
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Yawen Gai
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Yuting Zeng
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Xiaoxia Zhu
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Liya Chen
- The Statistics Room of Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Buling Wu
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| | - Wenjuan Yan
- Department of Conservative and Endodontic Dentistry, Nanfang Hospital, Southern Medical University, 1838 N Guangzhou Road, Guangzhou, 510515 China
| |
Collapse
|
11
|
Rodrigues VA, Dal Piva AMDO, Yamaguchi CA, Borges ALS, Mukai MK, Tribst JPM. Effect of framework type on survival probability of implant-supported temporary crowns: An in vitro study. J Clin Exp Dent 2020; 12:e433-e439. [PMID: 32509224 PMCID: PMC7263782 DOI: 10.4317/jced.56292] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 01/27/2020] [Indexed: 11/13/2022] Open
Abstract
Background This in vitro study evaluated the effect of framework type on the survival probability of temporary implant-supported crowns and on the implant platform structure after dynamic fatigue.
Material and Methods Thirty (30) external hexagon implants (3.75 x 10 mm) were embedded in acrylic resin following the ISO-14801. Standardized temporary crowns (n=10, N=30) were manufactured in acrylic resin and divided according to the framework type: Total plastic, Plastic with CoCr base and Titanium. The crowns were installed onto the implants (20N.cm) and fatigued (100N, 2 Hz) to determine the crowns’ survival probability for missions of 300.000 and 600.000 cycles. Fatigue data were submitted to the Kaplan-Meier test followed by Wilcoxon and Log Rank, all with α = 5%. The implant platforms were parametrically inspected based on the scanning before and after the fatigue to evaluate the damage. The strain values were analyzed using One-way ANOVA and Tukey test, all with α = 5%.
Results ANOVA revealed that the Total plastic showed less implant damage (-0.07 ± -0.03 mm) than the Plastic with CoCr base (-0.08 ± -0.04 mm) and the Titanium (-0.10 ± -0.01 mm) frameworks. Therefore, the framework type to manufacture implant-supported temporary crowns influences the fatigue survival of the restoration and the implant platform damage. The Plastic with CoCr base and Titanium frameworks showed superior reliability than the Total plastic framework which could not survive 600,000 cycles.
Conclusions The Plastic with CoCr base and the Titanium framework are suitable for restorations over 3 months in use, without a difference in the implant platform damage. Key words:Implant dentistry, axial loading, occlusion, methodological study.
Collapse
Affiliation(s)
- Vinícius-Anéas Rodrigues
- DDs, MSc, PhD, Department of Dental Materials and Proshodontics, Faculty of Pindamon-hangaba (FUNVIC), Pindamonhangaba/SP, Brazil
| | - Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Claudio-Akira Yamaguchi
- DDs, MSc at Department of Prosthodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, SP, Brazil
| | - Alexandre-Luiz-Souto Borges
- DDs, MSc, PhD, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| | - Marcio-Katsuyoshi Mukai
- DDs, MSc at Department of Prosthodontics, School of Dentistry, University of Sao Paulo, Sao Paulo, SP, Brazil
| | - João-Paulo-Mendes Tribst
- DDs, MSc, PhD, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil
| |
Collapse
|
12
|
Winter A, Schurig A, Rasche E, Rösner F, Kanus L, Schmitter M. The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2019; 31:9. [PMID: 31872290 DOI: 10.1007/s10856-019-6347-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 12/09/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES The purpose of this study was to investigate the fracture resistance, flexural strength and Weibull modulus of an innovative CAD/CAM polymer and to compare its fracture resistance with that of glass ceramics. MATERIALS AND METHODS A total of 32 (n = 16 IPS e.max CAD (LIDI); n = 16 LuxaCam Composite (LUXA)) first mandibular molar crowns were fabricated and cemented onto metal dies by use of luting composite. Half of the specimens were loaded until fracture without prior artificial ageing. The other half were subjected to thermal (5°/55 °C) and mechanical (1,200,000 cycles, 80 N) cycling before fracture loading. Scanning electron microscopy was used to analyse fracture behaviour. A three-point bending test of the flexural strength of LUXA was performed according to ISO 6872:2008. Data were analysed by means of the Kolmogorov-Smirnov test, Mann-Whitney U-test (p < 0.05) and Weibull statistical analysis. RESULTS Initial fracture resistance of LIDI was significantly higher than that of LUXA. However, the initial fracture resistance of LIDI decreased significantly after artificial ageing. After ageing, fracture resistance was 1050.29 ± 325.08 N for LUXA and 1250.09 ± 32.53 N for LIDI. Three-point bending test yielded a mean flexural strength value for LUXA of 145.28 ± 18.21 MPa and a Weibull modulus of m = 9.51. CONCLUSIONS Polymer-based material tested in this study had a lower fracture resistance than that of the glass-ceramic material. Fracture resistance and flexural strength of LuxaCam Composite are sufficient for use in the first molar region. CLINICAL RELEVANCE The mechanical properties of this innovative polymer-based material indicate it can be used in the first molar region as a suitable alternative to glass ceramics. Further clinical studies are required to confirm this. The study presents an innovative material as an alternative to glassceramic for the clinical use in dentistry. The materials investigated were differently affected by artificial aging. Clinical use for patients with bruxism may be considered.
Collapse
Affiliation(s)
- Anna Winter
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany.
| | - Axel Schurig
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany
| | - Engelke Rasche
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany
| | - Franziska Rösner
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany
| | - Lisa Kanus
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany
| | - Marc Schmitter
- Department of Prosthodontics, Julius Maximilians University Würzburg, Würzburg, Germany
| |
Collapse
|