1
|
Lima LCDE, Landmayer K, Braga MM, Scaramucci T, Palma-Dibb RG. EFFECT OF LASER IRRADIATION ASSOCIATED WITH FLUORIDE IN DECREASING EROSIVE TOOTH WEAR: A SYSTEMATIC REVIEW WITH A NETWORK META-ANALYSIS . J Evid Based Dent Pract 2024; 24:101990. [PMID: 39174162 DOI: 10.1016/j.jebdp.2024.101990] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 03/03/2024] [Accepted: 03/19/2024] [Indexed: 08/24/2024]
Abstract
OBJECTIVE The present systematic review with a network meta-analysis (NMA) aimed to evaluate the effect of high-power lasers, associated or not with fluoride compounds, to control and prevent Erosive Tooth Wear (ETW). METHODS The review was registered in the PROSPERO (CRD42021242547) and followed the PICO question: P (population): enamel and dentin substrate; I (Intervention): high-power laser irradiation, associated or not with fluoride compounds; C (Control): no-treatment; and O (Outcomes): prevention/control of ETW. The electronic databases PubMed, Scopus, and EMBASE were searched. Two independent reviewers evaluated in vitro and in situ studies. The risk of bias was assessed using the RoBDEMAT tool. The estimated treatment effect derived from direct and indirect comparisons were analyzed and the difference between these effects was calculated based on the data of enamel and dentin surface loss (in μm). RESULTS A total of 179 studies were retrieved and after the exclusion of duplicates, 103 studies had their titles and abstracts evaluated. Thirty-nine studies had their full text analyzed for data extraction (Cohen Kappa = 0.88). For sound enamel, the laser irradiation (L), fluoride application (F) and, the association of treatments (L + F) promoted higher protection than No-Treatment (NT). For eroded enamel, L + F and F did not differ, but both treatments reduced surface loss compared to NT and L. For sound and eroded dentin, treatments with laser increased surface loss. CONCLUSIONS Although a high-power laser has some potential to prevent erosive tooth wear, this effect is not better than that of standard fluoride. The use of laser in the management of dentin erosive wear can be harmful.
Collapse
Affiliation(s)
- Leonardo Custódio DE Lima
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil; Department of Dentistry, Federal University of Juiz de Fora, Governador Valadares, Minas Gerais, Brazil
| | - Karin Landmayer
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil
| | - Mariana Minatel Braga
- Department of Pediatric Dentistry, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil
| | - Taís Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, São Paulo, São Paulo, Brazil.
| | - Regina Guenka Palma-Dibb
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Ribeirão Preto, Brazil
| |
Collapse
|
2
|
Abd El-Aal NH, Hussein AMHMM, Banerjee A, Hammama HH. Clinical and ex-vivo effect of LASERs on prevention of early-enamel caries: systematic review & meta-analyses. Lasers Med Sci 2024; 39:107. [PMID: 38635085 PMCID: PMC11026291 DOI: 10.1007/s10103-024-04049-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 04/04/2024] [Indexed: 04/19/2024]
Abstract
To investigate the in vivo and in situ effect of different types of lasers in prevention of enamel demineralization in high caries risk cases (around orthodontic brackets, around restoration and in caries susceptible pits and fissures). PubMed was searched using the following keyword sequence; (Laser therapy OR laser irradiation OR laser application) AND (enamel caries prevention OR enamel demineralization OR enamel remineralization OR early enamel caries OR early-enamel caries OR enamel resistance OR enamel decalcification OR white spot lesions WSLs OR incipient lesion OR enamel decay OR enamel Dissolution OR enamel microhardness) AND (clinical trial OR Randomized clinical trial OR In situ study). The latest literature search was ended by "30 January 2023". PubMed was used as a primary data base for study selection. Scopus, EBSCO, and Google scholar are checked in our study after results of systematic search on PubMed. Only duplicates were found. Two meta-analyses were carried out. The first, clinical meta-analysis on incidence of white spot lesions (WSLs) following CO2 laser irradiation of enamel. The second meta-analysis on ex-vivo/in situ effect of CO2 laser on microhardness of enamel. In each meta-analysis three studies were included. Risk of bias was assessed. The search identified eight studies (four ex-vivo and four clinical trials). Regarding the clinical meta-analysis, the overall standardized mean difference was 0.21 [ 95% confidence interval (CI): 0.15-0.30, p < 0.00001]. This indicates that the incidence of new WSLs in patients who received low power CO2 laser treatment was highly significantly lower than placebo groups. The heterogeneity was considerable (I2 = 71%). In the second meta-analysis, the overall standardized mean difference was 49.55 [ 95% confidence interval (CI): 37.74, 61.37, p < 0.00001]. This indicates that microhardness of enamel receiving low power (0.4-5 W) CO2 laser irradiation is highly significantly lower than control untreated enamel. The heterogeneity was substantial (I2 = 48%). Within the limitations of this study, Low level laser therapy concept with CO2 laser seems to be effective in preventing enamel caries.Prospero registration number: CRD42023437379.
Collapse
Affiliation(s)
| | | | - Avijit Banerjee
- Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London, UK
| | | |
Collapse
|
3
|
Mapar M, Gholizadeh S, Moalemnia M. Effects of Two Remineralizing Agents in Combination with Er:YAG and CO 2 Laser Irradiation on Microhardness of Demineralized Enamel: A Preliminary In Vitro Study. Front Dent 2024; 21:11. [PMID: 38742220 PMCID: PMC11089429 DOI: 10.18502/fid.v21i11.15223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 07/20/2023] [Indexed: 05/16/2024] Open
Abstract
Objectives: This study assessed the effects of two remineralizing agents namely MI Paste Plus containing casein phosphopeptide amorphous calcium phosphate fluoride (CPP-ACFP) and Remin Pro containing hydroxyapatite, fluoride and xylitol (HFX) with/without erbium-doped yttrium aluminium garnet (Er:YAG) and CO2 laser irradiation on demineralized enamel microhardness. Materials and Methods: In this in vitro study, 70 sound human premolars were mesiodistally sectioned, demineralized at a pH of 4.6 for 8 hours, and randomly divided into 7 remineralization groups (n=10): of (I) MI Paste Plus (CPP-ACFP), (II) Remin Pro (HFX), (III) MI Paste Plus+CO2 laser (0.7 W power, 50 Hz), (IV) Remin Pro+CO2 laser, (V) MI Paste Plus+Er:YAG laser (1 W power, 10 Hz), (VI) Remin Pro+Er:YAG laser, and (VII) negative control. The Vickers hardness number of specimens was then measured. The groups were compared by one-way ANOVA and Tukey's test (α=0.05). Results: The mean microhardness was 319.8±49.9, 325.3±44.6, 359.4±35.7, 296.4±33.7, 319.9±58.1, 358.9±28.4, and 240.0±41.6 kg/mm2 in groups 1 to 7, respectively. The difference in microhardness was significant among the groups (P<0.0001). Pairwise comparisons revealed significant differences in microhardness between all groups (P≤0.03) except between groups 1 and 2, 1 and 5, 2 and 5, and 3 and 6 (P>0.05). Conclusion: Both Remin Pro (containing HFX) and MI Paste Plus (containing CPP-ACFP) can cause enamel remineralization. MI Paste Plus+CO2 laser irradiation and Remin Pro+Er:YAG laser irradiation were significantly more effective than the application of each remineralizing agent alone.
Collapse
Affiliation(s)
- Mehran Mapar
- Department of Restorative Dentistry, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Sara Gholizadeh
- Department of Restorative Dentistry, Khorasgan Islamic Azad Dental School, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Mina Moalemnia
- Department of Restorative Dentistry, School of Dentistry, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| |
Collapse
|
4
|
Protective effect of fluorides on erosion and erosion/abrasion in enamel: a systematic review and meta-analysis of randomized in situ trials. Arch Oral Biol 2020; 120:104945. [DOI: 10.1016/j.archoralbio.2020.104945] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/19/2020] [Accepted: 10/08/2020] [Indexed: 01/17/2023]
|
5
|
Molla Asadollah F, Mojahedi SM, Nojedehian H, Asnaashari M, Asnaashari N. The Effect of Er:YAG Laser Irradiation Combined With Fluoride Application on the Resistance of Primary and Permanent Dental Enamel to Erosion. J Lasers Med Sci 2019; 10:290-296. [PMID: 31875121 DOI: 10.15171/jlms.2019.47] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: Erosion is an important cause of tooth mineral loss. The combined use of lasers and fluoride has been introduced as a novel modality for the prevention of enamel demineralization. This study aimed to assess the effect of Er:YAG laser combined with fluoride application on primary and permanent enamel resistance to erosion. Methods: Eighty enamel specimens of permanent (n=40) and primary (n=40) molars were prepared and randomly assigned to 4 groups: C-control (no pretreatment), F-acidulated phosphate fluoride (APF) gel, FL-APF gel application followed by Er:YAG laser irradiation, and LF-Er:YAG laser irradiation followed by the application of APF gel . The specimens were then submitted to pH cycling using Coca-Cola (pH=2.4). Enamel micro-hardness was measured using the Vickers microhardness tester before pretreatment and after the erosive process. The collected data were analyzed using the Kolmogorov-Smirnov test, two-way ANOVA and repeated measures ANOVA. Results: The micro-hardness of both permanent and primary enamel specimens significantly decreased after the erosive process (P < 0.05). In the permanent enamel specimens, the greatest reduction in micro-hardness was noted in groups C and F, while the least reduction was noted in group FL. However, these differences were not statistically significant (P > 0.05). In the primary enamel specimens, the greatest reduction in micro-hardness was noted in groups C and LF, while the least reduction was noted in group F. These differences were not statistically significant (P > 0.05). Conclusion: Within the limitations of this study, Er:YAG laser irradiation combined with fluoride application could not prevent erosion in permanent and primary enamel during the erosive process.
Collapse
Affiliation(s)
- Fatemeh Molla Asadollah
- Department of Pediatric Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Seyed Masoud Mojahedi
- Department of Laser, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hanie Nojedehian
- Department of Dental Biomaterials, School of Dentistry, Shahid Beheshti University of Medical Sciences
| | - Mohammad Asnaashari
- Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Department of Endodontics, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Negin Asnaashari
- Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Influence of Ultrapulsed CO 2 Laser, before Application of Different Types of Fluoride, on the Increase of Microhardness of Enamel In Vitro. BIOMED RESEARCH INTERNATIONAL 2018; 2018:5852948. [PMID: 30175135 PMCID: PMC6106794 DOI: 10.1155/2018/5852948] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Accepted: 07/10/2018] [Indexed: 11/17/2022]
Abstract
Objective To evaluate the influence of ultrapulsed CO2 laser in combination with commercial fluoride products in order to verify the increase of microhardness of artificial enamel caries lesions. Materials and Methods Bovine enamel specimens were prepared, and artificial enamel caries lesions were created. Teeth were randomly divided into 5 groups (n=10): treated with laser (L), laser + neutral fluoride gel 2% (LNF), laser + acidulated phosphate fluoride gel 1.23% (LAFG), laser + acidulated fluoride mousse 1.23% (LAFM), and laser + fluoride varnish 5% (LFV). Microhardness was evaluated at baseline, after caries induction, after CO2 laser irradiation + fluoride treatment in the 1st week, and after fluoride treatment at 3rd and 5th week. Results There was a decrease in microhardness in all groups after artificial enamel caries lesion formation; no increase in microhardness was found in the first and third weeks in all groups (p > 0.05). In the fifth week, an increase in microhardness occurred in all groups (p < 0.05). Conclusion Although CO2 laser irradiation in combination with different commercial fluoride products was capable of increasing microhardness on enamel caries lesions in bovine tooth enamel it is necessary to confirm these results by testing the isolated effect of fluoride on enamel surface microhardness. Also, although microhardness was higher in the fluoride varnish group than in the other groups in the fifth week it is not possible to discard the best effect of fluoride varnish treatment on absence of artifacts that may occur with the other fluoride treatments. Clinical Relevance In order to prove that CO2 laser may contribute to an increase in microhardness when applied to enamel lesions in combination with different commercial fluoride products it is necessary to conduct additional studies. Also, higher microhardness of fluoride varnish group should be carefully considered.
Collapse
|
7
|
Bezerra SJC, Trevisan LR, Viana IEL, Lopes RM, Pereira DL, Aranha ACC, Scaramucci T. Er,Cr:YSGG laser associated with acidulated phosphate fluoride gel (1.23% F) for prevention and control of dentin erosion progression. Lasers Med Sci 2018; 34:449-455. [PMID: 30215185 DOI: 10.1007/s10103-018-2609-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Accepted: 08/03/2018] [Indexed: 10/28/2022]
Abstract
To evaluate the effect of Er,Cr:YSGG laser, associated with fluoride application, on the prevention/control of dentin erosion. Dentin slabs were embedded in acrylic resin, flattened, and polished. Half of the specimens were previously eroded (10 min immersion in 1% citric acid solution) and half were kept sound. The specimens (n = 10 each substrate) were randomly allocated into the experimental groups, according to the following treatments: control (no treatment); APF gel (1.23% F, 1 min); Er,Cr:YSGG laser irradiation (P1: 0.25 W, 20 Hz, 2.8 J/cm2, tip S75, beam diameter of 750 μm, 1 mm away from the surface); Er,Cr:YSGG laser irradiation (P2: 0.50 W, 20 Hz, 5.7 J/cm2, tip S75, beam diameter of 750 μm, 1 mm away from the surface); APF gel + Er,Cr:YSGG laser P1 and; APF gel + Er,Cr:YSGG laser P2. Afterwards, the specimens underwent an erosion-remineralization cycling, consisting of a 5-min immersion into 0.3% citric acid, followed by 60-min exposure to artificial saliva. This procedure was repeated 4×/day, for 5 days. Surface loss (SL, in μm) was determined by optical profilometry. Specimens from each group were analyzed by environmental scanning electron microscopy (n = 3). Data were statistically analyzed (α = 0.05). For the eroded specimens, APF gel presented the lowest SL, being different from the control. For the sound specimens, none of the groups differed from the control, except for Er,Cr:YSGG laser P2, which presented the highest SL. When substrates were compared, only the eroded specimens of the control and APF + Er,Cr:YSGG laser P1 Groups showed higher SL. Selective structure removal was observed for the laser-treated groups. None of the Er,Cr:YSGG laser parameters were effective in the prevention/control dentin erosion. The laser was also unable to enhance the protection of fluoride against dentin erosion.
Collapse
Affiliation(s)
- S J C Bezerra
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - L R Trevisan
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - I E L Viana
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - R M Lopes
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - D L Pereira
- Institute of Energetic and Nuclear Research, IPEN/CNEN/SP, Av. Prof. Lineu Prestes 2242, São Paulo, SP, 05508-000, Brazil
| | - A C C Aranha
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil.,Special Laboratory of Lasers in Dentistry (LELO), Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil
| | - Taís Scaramucci
- Department of Restorative Dentistry, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, São Paulo, SP, 05508-000, Brazil.
| |
Collapse
|
8
|
de Oliveira RM, de Souza VM, Esteves CM, de Oliveira Lima-Arsati YB, Cassoni A, Rodrigues JA, Brugnera Junior A. Er,Cr:YSGG Laser Energy Delivery: Pulse and Power Effects on Enamel Surface and Erosive Resistance. Photomed Laser Surg 2018; 35:639-646. [PMID: 29099682 DOI: 10.1089/pho.2017.4347] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND High power lasers have been suggested as a useful tool for dental caries and erosion prevention due to the increase of enamel acid resistance. OBJECTIVE to evaluate the effect of Er,Cr:YSGG (erbium,chromium:yttrium, scandium, gallium, garnet) laser irradiation pulse frequency and power on enamel surface and acid erosion resistance. METHODS By combining pulse frequency (5-75 Hz) and power settings (0.10-1.00 W), 20 irradiated groups and one nonirradiated control group were tested. A total of 63 bovine enamel blocks (n = 3/group) were prepared for surface hardness and roughness evaluation, performed in three phases: baseline, after irradiation, and after erosive challenge. Enamel blocks were irradiated with Er,Cr:YSGG laser with MZ8 tip (iPlus; Waterlase, Biolase, CA) for 30 sec according to experimental group and submitted. Erosive challenge consisted of four cycles alternating immersion in 0.01 M HCl (5 mL/mm2; 2 min; at 37°C) and immersion in artificial saliva for 3 h. Analysis of variance (three-way ANOVA), Tukey's test, and Pearson correlation were performed for the statistical analysis (p < 0.05). RESULTS After irradiation, groups irradiated with pulse frequency of 10 and 15 Hz showed a decrease in surface hardness. After erosive challenge, 5 and 75 W groups showed increase in surface hardness; 0.25, 0.5, 0.75, and 1 W groups showed minor alterations in surface roughness. CONCLUSIONS the irradiation of Er,Cr:YSGG laser with different parameters of power and pulse frequency settings may alter enamel surface and erosive resistance differently. Pulse frequency of 30 Hz and power of 0.50 W was considered the best parameter to prevent enamel acid erosion.
Collapse
Affiliation(s)
- Renan Mota de Oliveira
- 1 Division of Dental Research and Graduate Studies, Department of Restorative Dentistry, Guarulhos University , Guarulhos, Brazil
| | - Vinicius Matsuzaki de Souza
- 1 Division of Dental Research and Graduate Studies, Department of Restorative Dentistry, Guarulhos University , Guarulhos, Brazil
| | - Camila Machado Esteves
- 1 Division of Dental Research and Graduate Studies, Department of Restorative Dentistry, Guarulhos University , Guarulhos, Brazil
| | | | - Alessandra Cassoni
- 1 Division of Dental Research and Graduate Studies, Department of Restorative Dentistry, Guarulhos University , Guarulhos, Brazil
| | - José Augusto Rodrigues
- 1 Division of Dental Research and Graduate Studies, Department of Restorative Dentistry, Guarulhos University , Guarulhos, Brazil
| | - Aldo Brugnera Junior
- 3 Basic Optics and Applied to Life Sciences, The National Institute of Science and Technology-INCT , São Paulo, Brazil
| |
Collapse
|
9
|
Scatolin RS, Colucci V, Lepri TP, Alexandria AKD, Maia LC, Galo R, Borsatto MC, Corona SAM. Non-contact profilometry of eroded and abraded enamel irradiated with an Er:YAG laser. J Appl Oral Sci 2018; 26:e20170029. [PMID: 29742259 PMCID: PMC5933827 DOI: 10.1590/1678-7757-2017-0029] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Accepted: 09/15/2017] [Indexed: 11/21/2022] Open
Abstract
Literature has reported positive results regarding the use of lasers in the control of erosive lesions; however, evaluating whether they are effective in the control of the progression of erosive/abrasive lesions is important.
Collapse
Affiliation(s)
- Renata Siqueira Scatolin
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brasil
| | - Vivian Colucci
- Departamento de Odontologia, Universidade de Ribeirão Preto, Ribeirão Preto, São Paulo, Brasil
| | - Taísa Penazzo Lepri
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brasil
| | - Adílis Kalina de Alexandria
- Departamento de Odontopediatria e Ortodontia, Faculdade de Odontologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Rio de Janeiro, Brasil
| | - Lucianne Cople Maia
- Departamento de Odontopediatria e Ortodontia, Faculdade de Odontologia, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Rio de Janeiro, Brasil
| | - Rodrigo Galo
- Departamento de Odontologia, Universidade do Vale do Jequitinhonha e Mucuri, Diamantina, Minas Gerais, Brasil
| | - Maria Cristina Borsatto
- Departamento de Clínica Infantil, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brasil
| | - Silmara Aparecida Milori Corona
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, São Paulo, Brasil
| |
Collapse
|
10
|
Passos VF, Rodrigues LKA, Santiago SL. The effect of magnesium hydroxide-containing dentifrice using an extrinsic and intrinsic erosion cycling model. Arch Oral Biol 2018; 86:46-50. [DOI: 10.1016/j.archoralbio.2017.11.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2017] [Revised: 10/23/2017] [Accepted: 11/13/2017] [Indexed: 01/29/2023]
|