Madanat L, France J, Shoukri N, Bilolikar AN, Walsh D, Kutinsky I, Gundlapalli S, Zhao L, Goel A, Williamson B, Cami E, Gallagher M, Bloomingdale R, Dixon S, Haines D, Mehta N. Impact of Defibrillator Electrode Placement on Outcome of Electrical Cardioversion of Atrial Fibrillation: A Pilot Observational Study.
J Am Heart Assoc 2024;
13:e034817. [PMID:
38934869 PMCID:
PMC11255716 DOI:
10.1161/jaha.123.034817]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Accepted: 05/03/2024] [Indexed: 06/28/2024]
Abstract
BACKGROUND
Anterior-posterior electrode placement is preferred in electrical cardioversion of atrial fibrillation. However, the optimal anterior-posterior electrode position in relation to the heart is not studied.
METHODS AND RESULTS
We performed a prospective observational study on patients presenting for cardioversion of atrial fibrillation. Electrodes were placed in the anterior-posterior position and shock was delivered in a step-up approach (100 J→200 J→360 J). Fluoroscopic images were obtained, and distances were measured from points A, midanterior electrode; and B, midposterior electrode, to midpoint of the cardiac silhouette. Patients requiring one 100 J shock for cardioversion success (group I) were compared with those requiring >1 shock/100 J (group II). Logistic regression was used to determine the impact of electrode distance on low energy (100 J) cardioversion success. Computed tomography scans from this cohort were analyzed for anatomic landmark correlation to the cardiac silhouette. Of the 87 patients included, 54 (62%) comprised group I and 33 (38%) group II. Group I had significantly lower distances from the mid-cardiac silhouette to points A (5.0±2.4 versus 7.4±3.3 cm; P<0.001) and B (7.3±3.0 versus 10.0±3.8 cm; P=0.002) compared with group II. On multivariate analysis, higher distances from the mid-cardiac silhouette to point A (odds ratio, 1.33 [95% CI, 1.07-1.70]; P=0.01) and B (odds rsatio, 1.24 [95% CI, 1.05-1.50]; P=0.01) were independent predictors of low energy (100 J) cardioversion failure. Based on review of computed tomography scans, we suggest that the xiphoid process may be an easy landmark to guide proximity to the myocardium.
CONCLUSIONS
In anterior-posterior electrode placement, closer proximity to the cardiac silhouette predicts successful 100 J cardioversion irrespective of clinical factors.