Christou GA, Pagourelias ED, Deligiannis AP, Kouidi EJ. Exploring the Anthropometric, Cardiorespiratory, and Haematological Determinants of Marathon Performance.
Front Physiol 2021;
12:693733. [PMID:
34539429 PMCID:
PMC8446630 DOI:
10.3389/fphys.2021.693733]
[Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Accepted: 08/11/2021] [Indexed: 11/13/2022] Open
Abstract
Aim
We aimed to investigate the main anthropometric, cardiorespiratory and haematological factors that can determine marathon race performance in marathon runners.
Methods
Forty-five marathon runners (36 males, age: 42 ± 10 years) were examined during the training period for a marathon race. Assessment of training characteristics, anthropometric measurements, including height, body weight (n = 45) and body fat percentage (BF%) (n = 33), echocardiographic study (n = 45), cardiopulmonary exercise testing using treadmill ergometer (n = 33) and blood test (n = 24) were performed. We evaluated the relationships of these measurements with the personal best marathon race time (MRT) within a time frame of one year before or after the evaluation of each athlete.
Results
The training age regarding long-distance running was 9 ± 7 years. Training volume was 70 (50-175) km/week. MRT was 4:02:53 ± 00:50:20 h. The MRT was positively associated with BF% (r = 0.587, p = 0.001). Among echocardiographic parameters, MRT correlated negatively with right ventricular end-diastolic area (RVEDA) (r = -0.716, p < 0.001). RVEDA was the only independent echocardiographic predictor of MRT. With regard to respiratory parameters, MRT correlated negatively with maximum minute ventilation indexed to body surface area (VEmax/BSA) (r = -0.509, p = 0.003). Among parameters of blood test, MRT correlated negatively with haemoglobin concentration (r = -0.471, p = 0.027) and estimated haemoglobin mass (Hbmass) (r = -0.680, p = 0.002). After performing multivariate linear regression analysis with MRT as dependent variable and BF% (standardised β = 0.501, p = 0.021), RVEDA (standardised β = -0.633, p = 0.003), VEmax/BSA (standardised β = 0.266, p = 0.303) and Hbmass (standardised β = -0.308, p = 0.066) as independent variables, only BF% and RVEDA were significant independent predictors of MRT (adjusted R2 = 0.796, p < 0.001 for the model).
Conclusions
The main physiological determinants of better marathon performance appear to be low BF% and RV enlargement. Upregulation of both maximum minute ventilation during exercise and haemoglobin mass may have a weaker effect to enhance marathon performance.
Clinical Trial Registration
www.ClinicalTrials.gov, identifier NCT04738877.
Collapse