1
|
Luevitoonvechakij N, Buranapim N, Suriyasathaporn W, Bansiddhi P, Warrit K, Punyapornwithaya V, Suriyasathaporn W. Cadaveric Study on Comparison of Neck Extension Angles for Endotracheal Intubation in Rabbits Using a Rigid and Flexible Endoscope. Animals (Basel) 2024; 14:1270. [PMID: 38731275 PMCID: PMC11083616 DOI: 10.3390/ani14091270] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 04/19/2024] [Accepted: 04/22/2024] [Indexed: 05/13/2024] Open
Abstract
Endotracheal intubation in rabbits is always challenging due to the unique anatomical conformation. To improve endotracheal intubation success, this study determined the relationship between head placement angles guided by endoscope-assisted visualization techniques and the endotracheal intubation success rate. Thirty-two rabbit cadavers were used in the study. Six veterinary practitioners who had no experience with rabbit endotracheal intubation were randomly assigned to intubate rabbit cadavers using the guidance of either a rigid endoscope (RE) or flexible endoscope (FE), with the head placement angles with an ascending neck at 90, 100, 110, 120 and 130 degrees. The endotracheal intubation completed in 90 s was determined to be a success. The success rates using RE and FE were 97.2% and 95.9%, respectively. The means and standard error of means (SEM) of endotracheal intubation times guided by RE and FE were 53.7 ± 4.68 and 55.2 ± 4.24 s, respectively. Results from survival time analysis show that the five veterinarians successfully intubated the rabbit within 90 s, regardless of the different types of endoscopes. Angle was the only significant factor that affected the endotracheal intubation success. The head placement angle at 110 and 120 degrees had the highest success rate of endotracheal intubation compared to 90 degrees (p ≤ 0.05). In conclusion, for inexperienced veterinarians, the success of endotracheal intubation in rabbits, guided by endoscope-assisted visualized techniques regardless of rigid endoscope or flexible endoscope guidance, is improved when the head extension is 110 and 120 degrees.
Collapse
Affiliation(s)
- Nicharee Luevitoonvechakij
- Graduate Program in Veterinary Science, Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand;
- Center of Elephant and Wildlife Health, Chiang Mai University Animal Hospital, Chiang Mai University, Chiang Mai 50100, Thailand;
| | - Nithidol Buranapim
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Witaya Suriyasathaporn
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
- Research Center of Producing and Development of Products and Innovations for Animal Health and Production, Chiang Mai University, Chiang Mai 50100, Thailand
- Asian Satellite Campuses Institute, Nagoya University, Nagoya 464-8603, Japan
| | - Pakkanut Bansiddhi
- Center of Elephant and Wildlife Health, Chiang Mai University Animal Hospital, Chiang Mai University, Chiang Mai 50100, Thailand;
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Kanawee Warrit
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Veerasak Punyapornwithaya
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
| | - Wanna Suriyasathaporn
- Faculty of Veterinary Medicine, Chiang Mai University, Chiang Mai 50100, Thailand; (N.B.); (W.S.); (K.W.); (V.P.)
- Research Center of Producing and Development of Products and Innovations for Animal Health and Production, Chiang Mai University, Chiang Mai 50100, Thailand
| |
Collapse
|
2
|
Bruce H, Brennan M. Does an endotracheal tube or a v-gel result in better controlled ventilation in anaesthetised rabbits? Vet Rec 2023; 193:326-327. [PMID: 37861156 DOI: 10.1002/vetr.3585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2023]
Affiliation(s)
- Hayley Bruce
- School of Veterinary Medicine and Science, University of Nottingham, Sutton Bonington, UK
| | - Marnie Brennan
- School of Veterinary Medicine and Science, University of Nottingham, Sutton Bonington, UK
| |
Collapse
|
3
|
Lambertini C, Grandis A, De Silva M, Cassano IA, Checcacci Carboni S, Romagnoli N. The Spritztube: A New Device for the Extraglottic Intubation of Rabbits. Animals (Basel) 2022; 13:ani13010156. [PMID: 36611764 PMCID: PMC9817887 DOI: 10.3390/ani13010156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Revised: 12/27/2022] [Accepted: 12/27/2022] [Indexed: 01/03/2023] Open
Abstract
The Spritztube (ST) is an extraglottic airway device developed for humans. The aim of the study was to design an ST for rabbits and to evaluate its feasibility. The study was divided into two phases. Phase I: anatomical study on 12 rabbit cadavers to design 2 STs (8 and 10 Ch, external diameter) for rabbits. Phase II: fourteen privately owned rabbits were anaesthetised, and intubation was attempted using a ST. Tube size, the method for confirming the correct positioning, the number of attempts, the time needed for the correct positioning of the ST and complications were recorded. The ST placement was feasible in all rabbits. The positioning of the ST was completed in 2.1 ± 1 attempts in 43 ± 21.4 s. A correct placement was confirmed by the visualisation of the proximal cuff at visual inspection of the oral cavity (14/14), by the detection of the airflow (9/14 rabbits) and by the visualisation of a capnographic wave (14/14 rabbits). Only one rabbit developed respiratory distress after the ST placement. The results of the present study allowed designing a ST specific for rabbits which was used a supraglottic airway device for the maintenance of isoflurane anaesthesia in spontaneously breathing rabbits.
Collapse
Affiliation(s)
- Carlotta Lambertini
- Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
| | - Annamaria Grandis
- Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
| | - Margherita De Silva
- Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
| | | | | | - Noemi Romagnoli
- Department of Veterinary Medical Sciences, Alma Mater Studiorum-University of Bologna, Via Tolara di Sopra 50, Ozzano Emilia, 40064 Bologna, Italy
- Correspondence:
| |
Collapse
|
4
|
Huckins GL, Doss GA, Ferreira TH. Evaluation of supraglottic airway device use during inhalation anesthesia in healthy African pygmy hedgehogs (Atelerix albiventris). Vet Anaesth Analg 2021; 48:517-523. [PMID: 33903071 DOI: 10.1016/j.vaa.2021.03.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate a supraglottic airway device (SGAD) designed for rabbits in African pygmy hedgehogs (Atelerix albiventris) during inhalation anesthesia. STUDY DESIGN Prospective, randomized, blinded experimental study. ANIMALS A total of 12 adult African pygmy hedgehogs (seven male, five female). METHODS Hedgehogs were placed in a chamber and anesthesia was induced using isoflurane in oxygen. Oropharyngeal endoscopy was performed and video recorded. The SGAD (v-gel R1) was inserted and connected to a Mapleson D circuit. Capnography, pulse oximetry and physiologic variables were measured during anesthesia, and lung inflation was tested at 10 and 20 cmH2O. With the SGAD temporarily disconnected, anesthetized hedgehogs were randomly positioned into right and left lateral, dorsal and sternal recumbency to evaluate the effect of a change in body position on SGAD placement. Oropharyngeal endoscopy was repeated at the end of anesthesia, and recovery time was recorded. Pre- and post-SGAD placement endoscopy videos were retrospectively reviewed and scored for gross trauma. RESULTS The median [interquartile range (IQR)] time to successful SGAD placement was 38 (16-68) seconds. The time to SGAD placement decreased as the study progressed. SGAD required repositioning in six hedgehogs, median 2.5 (IQR, 1-3.5) adjustments each, to successfully perform lung inflation or maintain capnography readings. Lung inflation at 10 cmH2O was successfully performed without leakage in nine animals, and in the other three animals after adjusting the SGAD at 1-2 time points. Inflation at 20 cmH2O was rarely achieved without an air leak. Changes in heart and respiratory rates during anesthesia were not clinically relevant. Median endoscopic scores were 0 (no lesions) for both pre-and postplacement. CONCLUSIONS AND CLINICAL RELEVANCE The SGAD was relatively quickly and easily placed, permitted lung inflation and caused no significant oropharyngeal damage. The SGAD is a practical option for airway management in African pygmy hedgehogs.
Collapse
Affiliation(s)
- Gail L Huckins
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA
| | - Grayson A Doss
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA.
| | - Tatiana H Ferreira
- Department of Surgical Sciences, University of Wisconsin-Madison, School of Veterinary Medicine, Madison, WI, USA
| |
Collapse
|
5
|
Comparison of blind intubation and a smartphone-based endoscope-assisted intubation in rabbits. Vet Anaesth Analg 2020; 47:826-834. [PMID: 32981837 DOI: 10.1016/j.vaa.2020.07.037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/23/2020] [Accepted: 07/28/2020] [Indexed: 12/12/2022]
Abstract
OBJECTIVE To compare between blind and smartphone-based endoscope-assisted techniques for endotracheal intubation in rabbits. STUDY DESIGN Prospective clinical study. ANIMALS A total of 34 rabbits. METHODS Rabbits were assigned to four groups: intubation by a veterinary anesthesiologist (VA) or an exotic pet medicine specialist (EPS) using blind or endoscope-assisted techniques. Propofol dose, number of attempts until successful intubation, total time for intubation, duration of the successful attempt and occurrence of lingual cyanosis/laryngeal lesions were recorded. Data were analyzed by t test, Wilcoxon-Mann-Whitney U test or chi-square test. Pearson correlation for body weight was performed. RESULTS The success rate of blind intubation was 88.9% and 77.8% for VA and EPS, respectively. Propofol dose, total and median number of attempts, total time for intubation and duration of the successful attempt were 3.1 (0-6.2) mg kg-1, 19, 2 (1-5), 79 ± 65 and 30 ± 20 seconds for VA and 1.5 (0-4.5) mg kg-1, 24, 3 (1-5), 136 ± 92 and 38 ± 16 seconds for EPS. The success rate of endoscope-assisted intubation was 87.5% for both operators. Propofol dose, total and median number of attempts, total time for intubation and duration of the successful attempt were 2.5 (1.3-7.4) mg kg-1, 22, 3 (1-5), 170 (65-368) and 46 (22-150) seconds for VA and 3.2 (0-6) mg kg-1, 11, 1 (1-4), 56 (27-432) and 55 (26-79) seconds for EPS. VA performed blind intubation more quickly, propofol dose was lower and cyanosis was less frequent than in the endoscope-assisted group. CONCLUSIONS AND CLINICAL RELEVANCE Both techniques were reliable for rabbit endotracheal intubation. Best results were achieved when the operator was experienced in the technique. The smartphone-based endoscope is a useful aid for rabbit intubation.
Collapse
|
6
|
Abstract
Even when performed by skilled operators, locating the nerves can be challenging in small exotic pets; in such cases, the use of an electrical nerve stimulator may be useful to confirm the correct identification of the target nerve. Exotic animal anesthesia and analgesia have dramatically progressed over the past decade and continue to do so as more research and technologies develop. Technological advancements such as airway devices, endoscopic intubation techniques, positive intermittent pressure ventilators, and invasive and noninvasive blood pressure monitors have played a significant role in improving patient safety and the anesthetic outcomes of exotic animals.
Collapse
|
7
|
Affiliation(s)
- Adrianna Skarbek
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| | - Karla Borland
- Anderson Moores Veterinary Specialists, The Granary, Bunstead Barns, Poles Lane, Hursley, Winchaster, Hampshire, SO21 2LL
| |
Collapse
|
8
|
Wenger S, Müllhaupt D, Ohlerth S, Prasse S, Klein K, da Silva Valente B, Mosing M. Experimental evaluation of four airway devices in anaesthetized New Zealand White rabbits. Vet Anaesth Analg 2017; 44:529-537. [DOI: 10.1016/j.vaa.2016.05.009] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 04/28/2016] [Accepted: 05/03/2016] [Indexed: 10/20/2022]
|
9
|
Engbers S, Larkin A, Rousset N, Prebble M, Jonnalagadda M, Knight CG, Pang DSJ. Comparison of a Supraglottic Airway Device (v-gel ®) with Blind Orotracheal Intubation in Rabbits. Front Vet Sci 2017; 4:49. [PMID: 28443290 PMCID: PMC5385366 DOI: 10.3389/fvets.2017.00049] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Accepted: 03/22/2017] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION Achieving a secure airway in rabbits is generally considered more difficult than in cats or dogs. Their relatively large tongue, small oropharyngeal cavity and glottis limit direct visualization. A rabbit-specific supraglottic airway device (SGAD) may offer benefits over blind orotracheal intubation. ANIMALS AND METHODS Fifteen adult New Zealand white rabbits were randomized to SGAD or orotracheal intubation (ETT). All animals were sedated with dexmedetomidine (0.1 mg kg-1 IM) and midazolam (0.5 mg kg-1 IM), followed by induction with alfaxalone (0.3 mg kg-1 IV). Two CT scans of the head and neck were performed, following sedation and SGAD/ETT placement. The following were recorded: time to successful device insertion, smallest cross-sectional airway area, airway sealing pressure, and histological score of tracheal tissue. Data were analyzed with a Mann-Whitney test. RESULTS Two rabbits were excluded following failed ETT. Body masses were similar [ETT; n = 6, 2.6 (2.3-4.5) kg, SGAD; n = 7, 2.7 (2.4-5.0) kg]. SGAD placement was significantly faster [33 (14-38) s] than ETT [59 (29-171) s]. Cross-sectional area (CSA) was significantly reduced from baseline [12.2 (6.9-3.4) mm2] but similar between groups [SGAD; 2.7 (2.0-12.3) mm2, ETT; 3.8 (2.3-6.6) mm2]. In the SGAD group, the device tip migrated into the laryngeal vestibule in 6/7 rabbits, reducing the CSA. ETT airway seals were higher [15 (10-20) cmH2O], but not significant [SGAD; 5 (5-20) cmH2O, p = 0.06]. ETT resulted in significantly more mucosal damage [histological score 3.3 (1.0-5.0)], SGAD; 0.67 (0.33-3.67). CONCLUSION The SGAD studied was faster to place and caused less damage than orotracheal intubation, but resulted in a similar CSA.
Collapse
Affiliation(s)
- Sarah Engbers
- Cochrane Veterinary Care Clinic, Cochrane, AB, Canada
| | - Amy Larkin
- Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - Nicolas Rousset
- Western Veterinary Specialist and Emergency Centre, Calgary, AB, Canada
| | - Melanie Prebble
- Western Veterinary Specialist and Emergency Centre, Calgary, AB, Canada
| | | | - Cameron G Knight
- University of Calgary Faculty of Veterinary Medicine (UCVM), Calgary, AB, Canada
| | - Daniel S J Pang
- Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, QC, Canada.,Groupe de recherche en pharmacologie animale du Québec (GREPAQ), Université de Montréal, Saint-Hyacinthe, QC, Canada
| |
Collapse
|
10
|
Barletta M, Kleine SA, Quandt JE. Assessment of v-gel supraglottic airway device placement in cats performed by inexperienced veterinary students. Vet Rec 2015; 177:523. [DOI: 10.1136/vr.103407] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2015] [Indexed: 12/26/2022]
Affiliation(s)
- M. Barletta
- Department of Large Animal Medicine; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| | - S. A. Kleine
- Department of Small Animal Medicine & Surgery; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| | - J. E. Quandt
- Department of Small Animal Medicine & Surgery; College of Veterinary Medicine, University of Georgia; Athens GA 30602 USA
| |
Collapse
|