1
|
Teixeira ÉF, Girundi ALG, Alexandrino LD, Morel LL, de Almeida MVR, Dos Santos VR, Fraga S, da Silva WJ, Mengatto CM. Effects of disinfection with a vinegar-hydrogen peroxide mixture on the surface characteristics of denture acrylic resins. Clin Oral Investig 2023; 28:45. [PMID: 38153515 DOI: 10.1007/s00784-023-05405-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 12/02/2023] [Indexed: 12/29/2023]
Abstract
OBJECTIVE This study aimed to investigate changes in the surface characteristics of two denture resins when disinfected with a vinegar-hydrogen peroxide (VHP) mixture. MATERIALS AND METHODS Microwave-polymerized or 3D printed acrylic resin disks were immersed for 900 min (simulating 90 daily uses) in the following solutions (N = 10): water; 0.5% sodium hypochlorite; hydrogen peroxide and water dilution (1:1 ratio); vinegar and water dilution (1:1 ratio); and VHP mixture. Surface roughness, Knoop microhardness, surface free energy, and scanning electron microscopic images were assessed before and after the immersions. Results were compared using the 2-way ANOVA for repeated measures and Tukey test, at 5% significance. RESULTS Surface roughness and microhardness did not differ (P > .05) among the solutions and times. Surface free energy and its dispersive component increased (P < .05) for all solutions. All solutions, except for water and VHP mixture, degraded microtopography. CONCLUSIONS The VHP mixture was not deleterious to conventional and 3D-printed resin surfaces. CLINICAL RELEVANCE Conventional and 3D printed resin dentures can be disinfected with a VHP mixture in a 1:1 ratio because this mixture does not substantially affect the surface characteristics after 90 daily immersions. On the contrary, sodium hypochlorite, hydrogen peroxide, and vinegar solutions, even in low concentrations, should be used with caution for denture disinfection because they may alter the resin microtopography over time.
Collapse
Affiliation(s)
- Érico Fabbro Teixeira
- School of Dentistry, Federal University of Rio Grande Do Sul (UFRGS), Rua Ramiro Barcelos, 2492, Porto Alegre, Rio Grande do Sul, Brazil
| | - Ana Luíza Gonçalves Girundi
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Larissa Dolfini Alexandrino
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Laura Lourenço Morel
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Marcus Vinicius Rocha de Almeida
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Vinicius Rodrigues Dos Santos
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Sara Fraga
- Division of Prosthodontics, Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande Do Sul (UFRGS), Rua Ramiro Barcelos, 2492, Porto Alegre, Rio Grande do Sul, Brazil
| | - Wander José da Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, Sao Paulo, Brazil
| | - Cristiane Machado Mengatto
- Division of Prosthodontics, Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande Do Sul (UFRGS), Rua Ramiro Barcelos, 2492, Porto Alegre, Rio Grande do Sul, Brazil.
| |
Collapse
|
2
|
da Costa RMB, Poluha RL, De la Torre Canales G, Junior JFS, Conti PCR, Neppelenbroek KH, Porto VC. The effectiveness of microwave disinfection in treating Candida-associated denture stomatitis: a systematic review and metaanalysis. Clin Oral Investig 2020; 24:3821-3832. [PMID: 32974776 DOI: 10.1007/s00784-020-03599-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 09/16/2020] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate the effectiveness of microwave disinfection in treating Candida-associated denture stomatitis (CADS). MATERIALS AND METHODS The PubMed/MEDLINE, Embase, and Scopus databases were searched for reports on randomized clinical trials (RCTs) published in English until May 2020 (PROSPERO CRD42020192062) that evaluated the treatment of CADS by using microwave disinfection. The main outcomes were the improvement of clinical signs and/or the decrease in the residual yeast present on the dentures and palatal mucosa. The mean differences, standard deviations, risk ratio, and 95% confidence interval were calculated by using the random-effects model. Heterogeneity was assessed by using Cochran's Q test and I2 values. The level of significance was set at α = 0.05. RESULTS Five RCTs with 245 participants were included. The descriptive investigations demonstrated that microwave disinfection was as effective (p > 0.05) as 0.2% chlorhexidine, 0.02% sodium hypochlorite, and topical nystatin (100.000 IU/mL), and was superior to topical miconazole in treating CADS. The metaanalysis did not show a statistical difference between microwave disinfection and nystatin (100.000 IU/mL) treatment in terms of mycological counts, cure, and recurrence rates (p > 0.05). CONCLUSION Microwave disinfection showed comparable results with those of conventional therapies for treating CADS. In addition, treatment with 650 W for 3 min once a week for 14 days had better cost-effect results, indicating both the prevention and treatment of CADS. CLINICAL RELEVANCE Our findings provide evidence regarding the treatment of CADS using microwave disinfection, and also indicating the best cost-effective option for this treatment modality.
Collapse
Affiliation(s)
- Rodrigo Moreira Bringel da Costa
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil.
| | - Rodrigo Lorenzi Poluha
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| | - Giancarlo De la Torre Canales
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| | - Joel Ferreira Santiago Junior
- Department of Health Sciences, School of Dentistry, Centro Universitário Sagrado Coração - UNISAGRADO, Irmã Arminda St., 10-50, Bauru, SP, 17011-160, Brazil
| | - Paulo Cesar Rodrigues Conti
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| | - Karin Hermana Neppelenbroek
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| | - Vinicius Carvalho Porto
- Department of Prosthodontics and Periodontics, Bauru School of Dentistry, University of São Paulo, Alameda Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| |
Collapse
|
3
|
Consani RLX, Folli BL, Nogueira MCF, Correr AB, Mesquita MF. Effect of Polymerization Cycles on Gloss, Roughness, Hardness and Impact Strength of Acrylic Resins. Braz Dent J 2017; 27:176-80. [PMID: 27058380 DOI: 10.1590/0103-6440201600733] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2015] [Accepted: 02/17/2016] [Indexed: 11/22/2022] Open
Abstract
The aim of this study was to evaluate the conventional and boiled polymerization cycles on gloss, roughness, hardness and impact strength of acrylic resins. Samples were made for each Classico and QC-20 materials (n=10) in dental stone molds obtained from rectangular metallic matrices embedded in metallic flasks. The powder-liquid ratio and manipulation of the acrylic resins' were accomplished according to manufacturers' instructions and the resins were conventionally packed in metallic flasks. After polymerization by (1) conventional: 74 °C for 9 h (Classico) and (2) boiled: 20 min (QC-20) cycles, the samples were deflasked after cooling at room temperature and conventionally finished and polished. The properties were evaluated after storage in water at 37 °C for 24 h. Gloss was verified with Multi Gloss 268 meter (Konica Minolta), surface roughness was measured with Surfcorder SE 1700 rugosimeter (Kosaka), Knoop hardness number was obtained with HMV-200 microdurometer, and impact strength was measured in an Otto Wolpert-Werke device by Charpy system (40 kpcm). Data were subjected to Student's t-test (at α=0.05). The results were: Gloss: 67.7 and 62.2 for Classico and QC-20 resins, respectively; Surface roughness: 0.874 and 1.469 Ra-µm for Classico and QC-20, respectively; Knoop hardness: 27.4 and 26.9 for Classico and QC-20, respectively; and Impact strength: 37.6 and 33.6 kgf/cm2 for Classico and QC-20, respectively. No statistically significant difference (p>0.05)were found between the resins for the evaluated properties. In conclusion, conventional and boiled polymerization cycles had similar effects on gloss, roughness, hardness and impact strength of both Classico and QC-20 resins.
Collapse
Affiliation(s)
- Rafael Leonardo Xediek Consani
- Department of Prosthodontics and Periodontology, Dental School of Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil
| | - Bianca L Folli
- Dental School of Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil
| | - Moises C F Nogueira
- Dental School of Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil
| | - Americo Bortolazzo Correr
- Department of Restorative Dentistry, Dental School of Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil
| | - Marcelo F Mesquita
- Department of Prosthodontics and Periodontology, Dental School of Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brazil
| |
Collapse
|
4
|
Polychronakis N, Yannikakis S, Zissis A. The Effect of Repeated Microwaving Disinfection on the Dimensional Stability of Acrylic Dentures. Acta Stomatol Croat 2016; 48:279-84. [PMID: 27688376 DOI: 10.15644/asc48/4/5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate the effect of repeated microwave disinfections on the dimensional stability of acrylic dentures. MATERIALS AND METHODS Three groups of dentures made of a heat polymerized acrylic resin were tested. I: dentures kept in water (control group). II: dentures microwaved daily while being immersed into water (wet disinfection). III: dentures microwaved daily without being immersed into water (dry disinfection).
Measurements were taken across three reference points, on two occasions: after curing and immersion in water for 24 hours, and one week later.
Data obtained were analyzed using one-way analysis of variance (ANOVA) and Scheffe's multiple range test. RESULTS The results showed that the microwave disinfection provokes dimensional changes of the same pattern (shrinkage). The dentures which underwent wet disinfection exhibited the greatest shrinkage (p<0.05). CONCLUSIONS Disinfection using microwave energy may cause dimensional changes (shrinkage) of complete dentures.
The microwave "dry disinfection" method can be safely applied in everyday practice since the dimensional changes which occurred seem to be of no clinical significance.
Collapse
Affiliation(s)
- Nick Polychronakis
- Assistant Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens, Greece
| | - Stavros Yannikakis
- Professor, Department of Dental Technology, Division of Removable Prosthodontics, Technological Educational Institution of Athens, Greece
| | - Alcibiades Zissis
- Associate Professor, Division of Removable Prosthodontics, Dental School, National and Kapodistrian University of Athens, Greece
| |
Collapse
|
5
|
Klironomos T, Katsimpali A, Polyzois G. The Effect of Microwave Disinfection on Denture Base Polymers, Liners and Teeth: A Basic Overview. Acta Stomatol Croat 2015; 49:242-53. [PMID: 27688409 PMCID: PMC4993596 DOI: 10.15644/asc49/3/7] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 06/29/2015] [Indexed: 10/31/2022] Open
Abstract
The aim of this paper was to overview the current scientific knowledge concerning the effect of microwave disinfection on denture related material properties. Cross-infection control in dentistry is a significant issue in everyday clinical practice due to the recent increase in some infectious diseases such as hepatitis B, C and AIDS and therefore numerous methods of disinfection have been used. The most widespread method of disinfection used in everyday practice is chemical, however, studies have suggested that chemical disinfectants alter the physical and mechanical properties of the acrylic resins and enable the growth and proliferation of certain bacteria. Therefore, microwaves were introduced as an easy to use-and-access, low cost, chemical free alternative. The question that arose was if and in what way the microwave irradiation affected the denture related material properties. Microwaving affects the denture resin bases, liners and teeth in different ways. The results showed that microwave disinfection could be a safe alternative for the disinfection of denture bases and liners compared to the chemical one, when the procedure is carried out in dry conditions, but could possibly cause dimensional changes of clinical significance on them when the irradiation takes place in wet environment. It also seems to have no detrimental effects of clinical importance on the flexural properties, impact strength and hardness of denture resins and the bond, flexural strength, porosity and hardness of denture liners. The effects of microwave disinfection on the hardness of denture teeth and teeth/denture bond strength are still controversial and no safe conclusions can be drawn.
Collapse
Affiliation(s)
| | | | - Gregory Polyzois
- Professor, Department of Removable Prosthodontics, Dental School, University of Athens, Athens, Greece
| |
Collapse
|
6
|
Jafari AA, Falah Tafti A, Hoseiny SM, Kazemi A. Antifungal Effect of Zataria multiflora Essence on Experimentally Contaminated Acryl Resin Plates With Candida albicans. IRANIAN RED CRESCENT MEDICAL JOURNAL 2015; 17:e16552. [PMID: 25763273 PMCID: PMC4341503 DOI: 10.5812/ircmj.16552] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Revised: 08/18/2014] [Accepted: 09/15/2014] [Indexed: 11/24/2022]
Abstract
Background: Adherence and colonization of Candida species particularly C. albicans on denture surfaces, forms a microbial biofilm, which may result denture stomatitis in complete denture users. Objectives: The purpose of the present study was to evaluate the antifungal effect Zataria multiflora essence in removing of Candida albicans biofilms on experimentally contaminated resin acryl plates. Materials and Methods: In the present experimental study, 160 resin acrylic plates (10 × 10 × 1 mm) were contaminated by immersion in 1 × 103 C. albicans suspension for 24 hours to prepare experimental Candida biofilms. The total number of Candida cells, which adhered to 20 randomly selected acryl resin plates was determined as the Candia load before cleaning. The remaining 140 plates were divided to seven groups of 20 and immersed in five concentrations of Zataria multiflora essence from 50 to 3.125 mg/mL as test, 100000 IU nystatin as the positive and sterile physiologic serum as the negative control. The remaining Candida cells on each acryl plate were also enumerated and data were analyzed using the SPSS 16 software with Kruskal-Wallis and Wilcoxon tests. Results: Zataria essence at concentrations of 50 and 25 mg/mL removed 100% of attached Candida cells similar to nystatine (MFC), while weaker Zataria essence solutions cleaned 88%, 60.5% and 44.7% of attached Candida cells. Kruskal-wallis test showed a statistically significant difference between all test groups (P = 0.0001). In this study 12.5 mg/mL concentration of Zataria multiflora was considered as the minimum inhibitory concentration (MIC90). Conclusions: Zataria essence, at concentrations of 50 and 25 mg/mL, effectively removed Candida cells that had adhered to the denture surface, similar to the level of removal observed for 100000 IU nystatin.
Collapse
Affiliation(s)
- Abbas Ali Jafari
- Department of Basic Science, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | - Abbas Falah Tafti
- Department of Prostodontics, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
- Corresponding Author: Abbas Falah Tafti, Department of Prostodontics, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran. Tel: +98-9133519212, Fax: +98-3518367636, E-mail:
| | - Seyed Mehdi Hoseiny
- Department of Prostodontics, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
| | - Abdolhossein Kazemi
- Infectious and Tropical Research Center, Tabriz University of Medical Sciences, Tabriz, IR Iran
| |
Collapse
|
7
|
Sesma N, Rocha AL, Laganá DC, Costa B, Morimoto S. Effectiveness of denture cleanser associated with microwave disinfection and brushing of complete dentures: in vivo study. Braz Dent J 2013; 24:357-61. [PMID: 24173256 DOI: 10.1590/0103-6440201302205] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Accepted: 06/14/2013] [Indexed: 11/22/2022] Open
Abstract
Complete dentures acts as a reservoir for microbial colonization, which may lead to systemic infections. Microwave irradiation has been used as an efficient method of denture disinfection. Even though current methods eliminate denture-base microorganisms, a recurrence rate of denture stomatitis (DS) is still observed among denture-wearing patients. It was hypothesized that microwave disinfection kills microorganisms but do not remove dead bacteria from the denture surface. To test this hypothesis, the biofilm found in the dentures of 10 patients with DS was evaluated. In addition, the effects of microwave irradiation plus brushing (MW+B) on the denture biofilm and the combination of denture cleanser with microwave irradiation and brushing (MW+DC+B) for the removal of denture-accumulating microorganisms were investigated. Microbiological data were analyzed statistically by nonparametric analysis (Friedman/Wilcoxon, α=0.05). MW+B and MW+DC+B were effective in reducing the rate of microorganisms (99.2% and 99.5% respectively), but without significant difference between them (p=0.553). However, it was observed that the complete removal of microorganisms from denture surface was only possible when all regimens were combined (MW+DC+B). Microwave irradiation in combination with soaking in denture cleanser and brushing effectively disinfected the dentures and removed denture biofilm.
Collapse
Affiliation(s)
- Newton Sesma
- Department of Prosthodontics, School of Dentistry, USP - University of São Paulo, São PauloSP, Brazil
| | | | | | | | | |
Collapse
|
8
|
Silva MABD, Vitti RP, Consani S, Sinhoreti MAC, Mesquita MF, Consani RLX. Linear dimensional change, compressive strength and detail reproduction in type IV dental stone dried at room temperature and in a microwave oven. J Appl Oral Sci 2013; 20:588-93. [PMID: 23138748 PMCID: PMC3881792 DOI: 10.1590/s1678-77572012000500016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2012] [Accepted: 09/14/2012] [Indexed: 11/22/2022] Open
Abstract
The type IV dental stone is widely used for the fabrication of dyes and master casts
for fixed and removable partial prostheses. It is typically normal to wait at least
24 hours for the casts to dry prior to beginning the laboratory procedures. The
waiting time has been shown to be greatly reduced by using microwave drying.
Collapse
Affiliation(s)
- Marcos Aurélio Bomfim da Silva
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil.
| | | | | | | | | | | |
Collapse
|
9
|
Ucar Y, Akova T, Aysan I. Mechanical Properties of Polyamide Versus Different PMMA Denture Base Materials. J Prosthodont 2012; 21:173-6. [DOI: 10.1111/j.1532-849x.2011.00804.x] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
10
|
Sesma N, Gil C, Kolikauskas WA, Silva RA, Pannuti CM. Temperature of denture base resin under different protocols of microwave irradiation. Braz Dent J 2011; 22:388-91. [PMID: 22011894 DOI: 10.1590/s0103-64402011000500007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This in vitro study evaluated the temperature of dentures after different microwave irradiation protocols. Two complete dentures (one maxillary and one mandibular denture) were irradiated separately 4 times for each of the following 5 protocols: dentures immersed in water (G1- 6 min, G2- 3 min); dentures kept dry (G3- 6 min); dentures placed in the steam sterilizer (G4- 6 min, G5- 3 min). The final temperature of the dentures was gauged in a thin and in a thick area of each denture with an infrared thermometer. All groups presented an increase in the resin base temperature. The thin areas of the dentures underwent greater heating than the thick areas. There was no significant difference (p>0.05) between the final mean temperatures of dentures immersed in water for 6 (G1) and 3 min (G2). However, the final mean temperatures recorded in G1 and G2 exceeded 71°C and were significantly higher (<0.001) than the final mean temperatures recorded in the other groups. It may be concluded that denture base resins subjected to microwave irradiation immersed in water may be exposed to deleterious temperatures.
Collapse
Affiliation(s)
- Newton Sesma
- Department of Prosthodontics, Dental School, University of São Paulo, Brazil.
| | | | | | | | | |
Collapse
|
11
|
Senna PM, Da Silva WJ, Faot F, Del Bel Cury AA. Microwave disinfection: cumulative effect of different power levels on physical properties of denture base resins. J Prosthodont 2011; 20:606-12. [PMID: 21980952 DOI: 10.1111/j.1532-849x.2011.00770.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
PURPOSE This study evaluated the cumulative effects of different microwave power levels on the physical properties of two poly(methylmethacrylate) (PMMA) denture base resins. MATERIALS AND METHODS Eight sets of four PMMA specimens each (two polymerized in a water bath and two using microwave energy) were immersed in beakers containing 200 ml of distilled water. Each beaker was subjected to microwave irradiation for 3 minutes at a power level of 450,630, or 900 W. The surface roughness, surface hardness, linear stability, flexural strength, elastic modulus, impact strength, and fractographic properties were evaluated after either 6 or 36 simulated disinfection cycles. The data were statistically analyzed using ANOVA and the Tukey post hoc test (α= 0.05). RESULTS The polymerization method did not influence any property (p > 0.05) except linear stability. The surface roughness (p < 0.001) and hardness (p= 0.011) increased after 36 irradiation cycles at 630 or 900 W. The resin polymerized using microwave energy exhibited greater linear distortion (p= 0.012), and there was a cumulative effect on linear stability for both resins (p < 0.001). No significant change (p > 0.05) was observed in flexural strength; however, the elastic modulus decreased (p= 0.008) after 36 disinfection cycles. The impact strength and crack propagation angles displayed no significant differences (p > 0.05). CONCLUSION Within the limitations of this study, it can be concluded that microwave disinfection at 450 W to 630 W for 3 minutes is safe for PMMA.
Collapse
Affiliation(s)
- Plinio M Senna
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil.
| | | | | | | |
Collapse
|
12
|
Wady AF, Machado AL, Vergani CE, Pavarina AC, Giampaolo ET. Impact strength of denture base and reline acrylic resins subjected to long-term water immersion. Braz Dent J 2011; 22:56-61. [DOI: 10.1590/s0103-64402011000100010] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Water may influence the mechanical properties of the acrylic resins. Thus, the effect of water storage on the impact strength (IS) of one denture base (Lucitone 550 - L) and four reline resins (Tokuyama Rebase II - T; UfiGel Hard - U; Kooliner - K; New Truliner - NT) was evaluated. Bars of L were made (60 x 6 x 2 mm) and relined (2 mm) with T, U, K, NT and L. Intact specimens of each material (60 x 6 x 4 mm) were also fabricated for comparative purposes. Specimens were submitted to Charpy impact tests without water storage (control) and after immersion in water for 7, 90 and 180 days. Data (kJ/m²) analyzed by two-way ANOVA and Tukey's test (p=0.05) revealed that after 90 days, U exhibited an increase in the IS (0.93) compared to 7 days (0.58). K (1.48) and L/K (7.21) exhibited a decrease at the 7-day period (1.01 and 3.23, respectively). NT (0.60) showed an increase in the IS after 180 days (1.52), whereas L/NT (7.70) showed a decrease (3.17). Water immersion improved the IS of U and NT, and decreased the IS of K, L/K, and L/NT. Water may affect differently the IS of acrylic resins and, consequently, the resistance to fracture of relined denture bases.
Collapse
|