1
|
Elemam RF, Azul AM, Dias J, El Sahli K, de Toledo Leonardo R. In Vitro Research Methods Used to Evaluate Shaping Ability of Rotary Endodontic Files-A Literature Review. Dent J (Basel) 2024; 12:334. [PMID: 39452462 PMCID: PMC11506251 DOI: 10.3390/dj12100334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2024] [Revised: 10/04/2024] [Accepted: 10/12/2024] [Indexed: 10/26/2024] Open
Abstract
BACKGROUND/OBJECTIVES In this article, we present a literature review of methods used to measure the shaping ability of endodontic rotary files, including the selection of endodontic sample type (extracted teeth versus simulated blocks) and an imaging evaluation method. This review was conducted as background research to identify concerns that arise when designing research studies in this domain and propose how the field can plan more systematic studies going forward. METHODS A literature search was conducted using PubMed, MEDLINE, Embase, ScienceDirect, Scopus, and e B-on databases, including studies published in English from January 2010 to June 2024. Only studies that specified in vitro or ex vivo methods for evaluating the endodontic performance of NiTi rotary files on canal transportation and centering ability were considered. RESULTS A total of 86 studies met the inclusion criteria from an initial pool of 651. Of these, 67 studies used extracted teeth, while 20 utilized simulated root canals in resin blocks. For evaluation methods, 55 studies employed Micro-Computed Tomography and Cone-Beam Computed Tomography (MCT + CBCT), 30 used Double Digital Images/Radiographs/Photographs (DDIR + DDIP) with software analysis, 1 used both DDIR and MCT, 1 used high-precision nano-CT, and 1 used a digital single-lens reflex (DSLR) camera. CONCLUSIONS The findings indicate that the MCT method and its advanced variations appear superior in many cases for evaluating the quality of root canal instrumentation due to their ability to provide detailed three-dimensional images. We also discuss the pros and cons of other evaluation methods, including CBCT and DDIR. Finally, we identify important factors to consider for optimizing future cross-study comparisons. This work highlights the importance of being familiar with shaping ability assessment methods as new instruments are introduced to the market.
Collapse
Affiliation(s)
- Ranya F. Elemam
- Restorative Dental Science Department, College of Dentistry, Gulf Medical University, Ajman P.O. Box 4184, United Arab Emirates
| | - Ana Mano Azul
- Egas Moniz School of Health and Science, Monte da Caparica, 2829-511 Almada, Portugal
- Egas Moniz Center for Interdisciplinary Research, Monte de Caparica, 2829-511 Almada, Portugal
| | - João Dias
- Egas Moniz School of Health and Science, Monte da Caparica, 2829-511 Almada, Portugal
- Egas Moniz Center for Interdisciplinary Research, Monte de Caparica, 2829-511 Almada, Portugal
| | - Khaled El Sahli
- The Libyan Authority for Scientific Research, Tripoli P.O. Box 80045, Libya
| | - Renato de Toledo Leonardo
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (Unesp), Araraquara 14801-903, SP, Brazil
| |
Collapse
|
2
|
Estrela C, Bueno MR, Rossi-Fedele G, Decurcio DA, Guedes OA, Sousa-Neto MD, Estrela CRDA. Method to determine the root canal spatial geometry using an algorithm of the e-Vol DX CBCT software. Braz Dent J 2023; 34:40-49. [PMID: 38133091 PMCID: PMC10742355 DOI: 10.1590/0103-6440202305661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
This study evaluated a method to determine the spatial geometry of root canal preparation (RCP) using navigation dynamics and a specific algorithm from a new CBCT software (e-Vol DX). CBCT scans of 168 root canals of mandibular molars were acquired before and after RCP, using nickel-titanium (NiTi) instruments (ProTaper Next, BioRace, Reciproc Blue, and WaveOne Gold). The spatial geometry of the root canals and the operative risk of disproportional wear of dentinal walls after RCP were evaluated using a new CBCT software. A 3-point scoring system was used after the measuring of cementum/dentin thickness before and after RCP in all root thirds. The root thirds were distributed into three parts of similar sizes, and the scores were categorized at three levels: 1. mild risk (1/3), 2. moderate risk (2/3), 3. severe risk (3/3). These levels were proposed according to the risk of creating disproportionate shapes, thin walls, or perforations. The data were analyzed statistically by Fischer's exact test (α = 5%). There were no significant differences in operative risk among the NiTi engine-driven systems, for the distal or mesial walls of all the root canal thirds (p>0.05). The spatial geometry method to assess operative risk allows clinical planning for a predictable enlargement of the root canal in all root thirds. Based on using a map-reading strategy on root canals in CBCT scans, NiTi engine-driven instruments did not present an increased operative risk during RCPs.
Collapse
Affiliation(s)
- Carlos Estrela
- Professor of Endodontics, School of Dentistry, Federal University of Goiás, Goiânia, Brazil
| | | | - Giampiero Rossi-Fedele
- Professor of Endodontics University of Adelaide, Dental School, Department of Endodontics, Adelaide, Australia
| | | | - Orlando Aguirre Guedes
- Professor of Oral Biology, School of Dentistry, Evangelical University of Goiás, GO, Brazil
| | - Manoel Damião Sousa-Neto
- Professor of Endodontics, School of Dentistry, University of São Paulo, Ribeirão Preto, SP, Brazil
| | | |
Collapse
|
3
|
Kapse BS, Nagmode PS, Vishwas JR, Karpe HB, Basatwar HV, Godge SP. Cone-beam Computed Tomographic Analysis of Canal Transportation and Centering Ability of Three Different Nickel-Titanium Rotary File Systems. Open Access Maced J Med Sci 2021. [DOI: 10.3889/oamjms.2021.5666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
AIM: The aim of the present study was to compare the canal transportation and centering ability of three rotary nickel-titanium file systems, HyFlex controlled memory, Revo-S, and Mtwo in moderately curved root canals using computed tomography (CT).
MATERIALS AND METHODS: Thirty freshly extracted single-rooted teeth having curved root canals with at least 10°–20° of curvature were selected. The teeth were divided into three experimental groups of ten each. After preparation with HyFlex CM (Coltene-Whaledent, Allstetten, Switzerland), Revo-S (Micro-Mega, Besançon, France), and Mtwo (VDW, Munich, Germany) all teeth were scanned using CT to determine the root canal shape. Pre- and post-instrumentation images were obtained at three levels, 3 mm apical, 9 mm middle, and 15 mm coronal above the apical foramen were compared using CT software. Amount of transportation and centering ability were assessed. The three groups were statistically compared with analysis of variance and post-hoc Tukey’s honestly significant difference test.
RESULTS: Least apical transportation and higher centering ability were seen in HyFlex CM file system in all the three sections followed by Revo-S, Mtwo file system showed maximum transportation.
CONCLUSIONS: According to the present in-vitro study, we can conclude that HyFlex CM rotary file systems showed least canal transportation and highest centering ability as compared to Revo-S and Mtwo file system but there was no statistically significant difference among these file systems (p > 0.05) at coronal, middle, and apical level of root canal.
Collapse
|
4
|
A Critical Review of Methods for Quantitative Evaluation of Root Canal Transportation. J Endod 2021; 47:721-731. [PMID: 33587997 DOI: 10.1016/j.joen.2021.02.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 11/22/2022]
Abstract
INTRODUCTION A comparison between root canal transportation studies is nearly impossible because of nonstandardized transportation evaluation methods. The aim of the present review was to search, compare, and critically discuss transportation evaluation methods. METHODS A search of PubMed, Web of Science, Scopus, ScienceDirect, and reference lists of articles was conducted up to March 2020 using appropriate key words to identify transportation evaluation methods. The methods in the included articles were extracted, compared, and categorized. RESULTS Seventy-four articles using original methods were selected. All studies share 3 main steps: image acquisition, image measurements, and calculation of parameters. Images were acquired by photography, radiography, and computed tomographic imaging. Two types of measurements were used: the amount of removed material and the canal center point distance. The parameters were calculated and reported as distance or ratio. Relationships between the different transportation parameters were found and confirmed with mathematical simulation. CONCLUSIONS Although methods were proposed as being novel, similarities between them were found, enabling the classification of the methods and identifying correlations. The canal center point distance is the most suitable for the description of canal transportation because it is comprehensible and it relates to the mathematical concept of translation. Removed material-based measurements are double the value of the canal center point distance. Ratio parameters are not suitable for reporting transportation.
Collapse
|
5
|
Yammine S, Jabbour E, Diemer F, Majzoub Z. Canal Straightening Following Overinstrumentation with Three Nickel-Titanium Rotary Instruments. J Int Soc Prev Community Dent 2018; 8:245-251. [PMID: 29911063 PMCID: PMC5985682 DOI: 10.4103/jispcd.jispcd_18_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 01/30/2018] [Indexed: 12/22/2022] Open
Abstract
AIM The aim of the present in vitro study to compare canal straightening following shaping of curved canals with three types of new generation nickel-titanium (NiTi) rotary instruments-ProTaper Next (PTN)®, BT RaCe (BTR)®, and WaveOne Gold (WOG)®- and three different levels of protrusion beyond the major apical foramen. MATERIALS AND METHODS Forty-five extracted human maxillary and mandibular molars with at least one curved canal were distributed in three comparable groups of 15 canals each. The canals were instrumented to the major foramen and then overinstrumented with the final file 0.5 mm, 1 mm, and 1.5 mm beyond the foramen using PTN (Group PTN = 15), BTR (Group BTR = 15), and WOG (Group WOG = 15). Standardized pre- and post-instrumentation radiographs of the root canal were obtained for all groups using digital intraoral radiographs coupled with software. Differences in the degree of curvature were regarded as straightening and canal curvature was evaluated based on Schneider technique using the AmScope software for measurements and compared between groups and levels of instrumentation applying Mixed-model ANOVA. Significance was set at 0.05. RESULTS Canal curvature tended to gradually straighten out as the level of instrumentation increased in all three groups without statistically significant difference among the groups (P = 0.826). CONCLUSION Overinstrumentation in curved canals resulted in straightening of the canal curvature.
Collapse
Affiliation(s)
- Salwa Yammine
- Department of Endodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| | - Edgard Jabbour
- Department of Endodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| | - Franck Diemer
- Université Paul Sabatier, Institut Clément Ader, CHU de Toulouse, France
| | - Zeina Majzoub
- Department of Periodontology, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| |
Collapse
|
6
|
Ahmed S, Ismail PMS, Sekhar MC, Reddy SNL, Krishna MG, Reddy UN, Nikhita K, Harish PS. Evaluation of Effect of Irrigants with or without Surfactant on Root Canal Transportation by Cone Beam Computed Tomography-An In vitro Study. J Clin Diagn Res 2017; 11:ZC75-ZC78. [PMID: 29207839 DOI: 10.7860/jcdr/2017/27258.10677] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Accepted: 06/08/2017] [Indexed: 11/24/2022]
Abstract
Introduction Maintenance of original canal anatomy with proper disinfection is our primary goal to achieve during root canal instrumentation. Surfactants are added to irrigating solution to promote deeper penetration into dentinal tubules. Aim The aim of this study was to evaluate the influence of addition of surfactants to Sodium Hypochlorite (NaOCl) and Ethylenediaminetetraacetic Acid (EDTA) on transportation of root canal. Materials and Methods Fifty human mandibular molars with mesial root curvatures of 10° - 40° were selected and embedded in silicone impression material to simulate mandibular arch form to facilitate imaging process and maintain reproducibility of images. Before instrumentation, root canals were scanned by using Cone Beam Computed Tomography (CBCT) imaging (Carestream, India). The canals were then prepared with the ProTaper Next (PTN) system (Dentsply Maillefer, Ballaigues, Switzerland), using one of the following irrigation regimens during the instrumentation and were divided into five groups based on irrigation regimens followed: G1 (n=10)-irrigation with saline solution(control); G2 (n=10)-irrigation with 2.5% NaOCl; G3 (n=10)-irrigation with 2.5% NaOCl added with surfactant; G4 (n=10)-irrigation with 17% EDTA; G5 (n=10)-irrigation with 17% EDTA added with surfactant. Post-instrumentation scans were obtained with similar parameters and position as pre-instrumentation scans by CBCT imaging. Transportation of the root canals were then analysed at three cross-sectional planes of pre-instrumentation and post-instrumentation images at 2 mm, 5 mm, 8 mm from the apical end of the root. The data was statistically analyzed using Analysis of Variance (ANOVA) and Tukey post hoc test (p<0.05). Results The mean transportation values were higher in G5. Transportation in G3 and G5 was not significantly different compared to G2 and G4 respectively (p<0.05). Conclusion Instrumentation using irrigating solutions added with surfactant like 1% cetrimide maintained the canal curvature well.
Collapse
Affiliation(s)
- Siddiq Ahmed
- Assistant Professor, Department of Conservative Dentistry, Ibn Sina National College for Medical Studies, Jeddah, Makkah, Saudi Arabia
| | - Prabu Mahin Syed Ismail
- Assistant Professor, Department of Conservative Dentistry, Ibn Sina National College for Medical Studies, Jeddah, Makkah, Saudi Arabia
| | - M Chandra Sekhar
- Professor, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| | - Sampathi Naga Lakshmi Reddy
- Professor, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| | - Moosani Gopi Krishna
- Professor, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| | - Upendra Natha Reddy
- Reader, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| | - Kalla Nikhita
- Postgraduate Student, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| | - P Sai Harish
- Postgraduate Student, Department of Conservative Dentistry, G Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India
| |
Collapse
|
7
|
Lopes DS, Pessoa MAV, Aguiar CM. Assessment of the Centralization of Root Canal Preparation with Rotary Systems. Acta Stomatol Croat 2016; 50:242-250. [PMID: 27847398 DOI: 10.15644/asc50/3/7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
OBJECTIVE Apical deviations are important factors in endodontic therapy, since they can cause the treatment failure. The aim of the present study was to determine the centering capacity of ProTaper Universal™, Twisted File™ and Revo-S® rotary systems using cone beam computed tomography analysis before and after the instrumentation of root canals. MATERIALS AND METHODS Thirty mesiobuccal roots from human lower first molars were divided into three groups of ten: Group 1 - ProTaper Universal™ Rotary System; Group 2 - Twisted File™ Rotary System; and Group 3 - Revo-S® Rotary System. All teeth were scanned using computed tomography to determine the condition of the root canal before and after instrumentation (4mm, 3mm and 2mm from the root apex). Images were made using ICAT VISION software for both instrumented and non-instrumented canals. RESULTS The results were analyzed statistically using the Kolmogorov-Smirnov normality test for quantitative variables. Comparisons were made with two groups (Mann-Whitney - abnormal) and with more than two groups (Kruskal Wallis - abnormal). The level of significance was set at p<0.05. A statistically significant difference was found for the measurement of 4 mm between the "ProTaper Universal" and "Twisted File" systems. For the Twisted File system, a statistically significant difference was recorded between the measurements of 4mm and 3 mm. CONCLUSION None of the assessed instruments was completely effective in terms of the biomechanical preparation of root canals since all created deviation from the original anatomy of the canal.
Collapse
Affiliation(s)
- Daniela Siqueira Lopes
- Department of Dental Prosthesis and Oral Facial Surgery, Federal University of Pernambuco, Recife, Brazil
| | | | - Carlos Menezes Aguiar
- Department of Dental Prosthesis and Oral Facial Surgery, Federal University of Pernambuco, Recife, Brazil
| |
Collapse
|
8
|
Lorencetti KT, Silva-Sousa YTC, Nascimento GED, Messias DCF, Colucci V, Abi Rached-Junior F, Silva SRC. Influence of apical enlargement in cleaning of curved canals using negative pressure system. Braz Dent J 2016; 25:430-4. [PMID: 25517780 DOI: 10.1590/0103-6440201302435] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Accepted: 10/06/2014] [Indexed: 11/22/2022] Open
Abstract
This study aimed to evaluate, by scanning electron microscopy (SEM), the cleaning of canal walls with moderate curvature subjected to biomechanical preparation with different final diameters using apical negative pressure irrigation. Thirty-two mesiobuccal roots of molars were divided into 4 groups (n=8) according to the instrument's final diameter: GI: 30.02, GII: 35.02, GIII: 40.02 and GIV: 45.02. Irrigating procedure was performed at each change of instrument with 1% NaOCl using the Endovac system. Final irrigation was conducted with 17% EDTA for 5 min. The SEM photomicrographs were evaluated under 35× and 1000× magnification, by three calibrated examiners, in a double-blind design. Data were submitted to Kruskal-Wallis and Dunn's post hoc tests (α=0.05). Canals instrumented with 30.02 and 35.02 final diameters showed more debris, statistically different from the other groups (p<0.05). Comparing each root canal third, for the cervical and apical portions no statistically significant difference (p>0.05) was found among the four groups. Regarding the presence of smear layer, canals with 30.02 final diameter showed the highest scores, statistically different from the 45.02 group (p<0.05) and similar to the 35.02 and the 40.02 groups (p>0.05). Although none of the studied diameters completely removed debris and smear layer, it may be concluded that instrumentation with higher final diameters was more effective in cleaning the root canals with moderate curvature.
Collapse
Affiliation(s)
| | | | | | | | - Vivian Colucci
- Dental School, University of Ribeirão Preto, Ribeirão Preto, SP, Brazil
| | | | | |
Collapse
|
9
|
Prasanthi NN, Rambabu T, Sajjan GS, Varma KM, Satish RK, Padmaja M. A comparative evaluation of the increase in root canal surface area and canal transportation in curved root canals by three rotary systems: A cone-beam computed tomographic study. J Conserv Dent 2016; 19:434-9. [PMID: 27656062 PMCID: PMC5026103 DOI: 10.4103/0972-0707.190003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Aim: The aim of this study was to measure the increase in root canal surface area and canal transportation after biomechanical preparation at 1, 3, and 5 mm short of the apex with three different rotary systems in both continuous rotary and reciprocating rotary motions. Materials and Methods: Sixty freshly extracted human mandibular molars with mesial root canal curvatures between 20° and 30° were included in the study. Teeth were randomly distributed into three groups (n = 20). Biomechanical preparations were done in all the mesial canals. In Group 1, instrumentation was done with ProTaper universal rotary files, Group 2, with K3XF rotary files, and Group 3, with LSX rotary files. Each group was further subdivided into subgroups A and B (n = 10) where instrumentation was done by continuous rotary and reciprocating rotary techniques, respectively. Increase in root canal surface area and canal transportation was measured using the preoperative and postoperative cone-beam computed tomography scans. Statistical Analysis: The data were analyzed by one-way ANOVA followed by Tukey pairwise multiple comparison tests. Results: Increase in root canal surface area was significantly more (P < 0.05) in ProTaper and K3XF groups when compared to LSX group. Canal transportation was significantly more (P < 0.05) in ProTaper group when compared to K3XF and LSX groups. There was no significant difference (P > 0.05) in increase of root canal surface area and canal transportation between continuous rotary and reciprocating rotary techniques for ProTaper Universal, K3XF and LSX groups. Conclusion: LSX rotary system showed minimal increase of root canal surface area and minimal canal transportation when compared to ProTaper and K3XF rotary systems.
Collapse
Affiliation(s)
- Nalam Nvd Prasanthi
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| | - Tanikonda Rambabu
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| | - Girija S Sajjan
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| | - K Madhu Varma
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| | - R Kalyan Satish
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| | - M Padmaja
- Department of Conservative Dentistry and Endodontics, Vishnu Dental College, West Godavari, Andhra Pradesh, India
| |
Collapse
|
10
|
Moazzami F, Khojastepour L, Nabavizadeh M, Seied Habashi M. Cone-Beam Computed Tomography Assessment of Root Canal Transportation by Neoniti and Reciproc Single-File Systems. IRANIAN ENDODONTIC JOURNAL 2016; 11:96-100. [PMID: 27141215 PMCID: PMC4841342 DOI: 10.7508/iej.2016.02.004] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Revised: 11/10/2015] [Accepted: 12/08/2015] [Indexed: 11/30/2022]
Abstract
Introduction: The aim of this in vitro study was to compare the canal transportation of two single-file engine-driven systems, Neoniti and Reciproc, using cone-beam computed tomography (CBCT). Methods and Materials: Forty-five non-calcified roots with mature apices and apical curvature of 15-30 degrees were selected from extracted human maxillary molars for this study. Samples were randomly divided into two groups (n=20) and a control group (n=5) and canal preparation with either system was performed according to manufacturers' instructions. Pre- and post-instrumentation CBCT images were captured and the amount of canal transportation within the files was calculated at levels of 3, 4, and 5 mm from the apex. The independent sample t-test was used to analyze the statistical significance between the two groups. The level of significance was defined at 0.05. Results: Reciproc created more canal transportation compared to Neoniti in both mesiodistal and buccolingual directions. The difference between the two systems was statistically significant in all evaluated distances from the apex (P<0.001). During this study fracture of one file (25/0.08) in the Neoniti group occurred. Conclusion: Neoniti and Reciproc systems have significant difference in terms of creating canal transportation. Reciproc created more canal transportation in buccolingual and mesiodistal dimensions.
Collapse
Affiliation(s)
- Fariborz Moazzami
- Department of Endodontics, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Leila Khojastepour
- Department of Oral and Maxillofacial Radiology, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammadreza Nabavizadeh
- Prevention of Oral and Dental Diseases Research Center, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mina Seied Habashi
- Department of Endodontics, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
11
|
Pedullà E, Plotino G, Grande NM, Avarotti G, Gambarini G, Rapisarda E, Mannocci F. Shaping ability of two nickel–titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study. Clin Oral Investig 2016; 20:2227-2233. [DOI: 10.1007/s00784-016-1732-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 01/19/2016] [Indexed: 10/22/2022]
|
12
|
Grande NM, Ahmed HMA, Cohen S, Bukiet F, Plotino G. Current Assessment of Reciprocation in Endodontic Preparation: A Comprehensive Review—Part I: Historic Perspectives and Current Applications. J Endod 2015; 41:1778-83. [DOI: 10.1016/j.joen.2015.06.014] [Citation(s) in RCA: 56] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 06/07/2015] [Accepted: 06/22/2015] [Indexed: 11/29/2022]
|
13
|
Agarwal RS, Agarwal J, Jain P, Chandra A. Comparative Analysis of Canal Centering Ability of Different Single File Systems Using Cone Beam Computed Tomography- An In-Vitro Study. J Clin Diagn Res 2015; 9:ZC06-10. [PMID: 26155551 DOI: 10.7860/jcdr/2015/12097.5863] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Accepted: 03/25/2015] [Indexed: 11/24/2022]
Abstract
BACKGROUND The ability of an endodontic instrument to remain centered in the root canal system is one of the most important characteristic influencing the clinical performance of a particular file system. Thus, it is important to assess the canal centering ability of newly introduced single file systems before they can be considered a viable replacement of full-sequence rotary file systems. AIM The aim of the study was to compare the canal transportation, centering ability, and time taken for preparation of curved root canals after instrumentation with single file systems One Shape and Wave One, using cone-beam computed tomography (CBCT). MATERIALS AND METHODS Sixty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20(o) to 35(o) were divided into three groups of 20 samples each: ProTaper PT (group I) - full-sequence rotary control group, OneShape OS (group II)- single file continuous rotation, WaveOne WO - single file reciprocal motion (group III). Pre instrumentation and post instrumentation three-dimensional CBCT images were obtained from root cross-sections at 3mm, 6mm and 9mm from the apex. Scanned images were then accessed to determine canal transportation and centering ability. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference test. RESULTS It was observed that there were no differences in the magnitude of transportation between the rotary instruments (p >0.05) at both 3mm as well as 6mm from the apex. At 9 mm from the apex, Group I PT showed significantly higher mean canal transportation and lower centering ability (0.19±0.08 and 0.39±0.16), as compared to Group II OS (0.12±0.07 and 0.54±0.24) and Group III WO (0.13±0.06 and 0.55±0.18) while the differences between OS and WO were not statistically significant. CONCLUSION It was concluded that there was minor difference between the tested groups. Single file systems demonstrated average canal transportation and centering ability comparable to full sequence Protaper system in curved root canals.
Collapse
Affiliation(s)
- Rolly S Agarwal
- Reader, Department of Conservative Dentistry & Endodontics, Sri Aurobindo College of Dentistry , Indore, Madhya Pradesh, India
| | - Jatin Agarwal
- Reader, Department of Prosthodontics, Sri Aurobindo College of Dentistry , Indore, Madhya Pradesh, India
| | - Pradeep Jain
- Professor, Department of Conservative Dentistry & Endodontics, Sri Aurobindo College of Dentistry , Indore, Madhya Pradesh, India
| | - Anil Chandra
- Professor, Department of Conservative Dentistry & Endodontics, Faculty of Dentistry, King George Medical University , Lucknow, Uttar Pradesh, India
| |
Collapse
|
14
|
Gundappa M, Bansal R, Khoriya S, Mohan R. Root canal centering ability of rotary cutting nickel titanium instruments: A meta-analysis. J Conserv Dent 2014; 17:504-9. [PMID: 25506134 PMCID: PMC4252920 DOI: 10.4103/0972-0707.144567] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 08/04/2014] [Accepted: 09/01/2014] [Indexed: 11/20/2022] Open
Abstract
Aim: To systematically review articles on canal centering ability of endodontic rotary cutting Nickel-Titanium (Ni-Ti) instruments and subject results to meta-analysis. Materials and Methods: A comprehensive search was initiated on canal centering ability of different rotary cutting Ni-Ti files such as Protaper, Hero Shaper, K3, Mtwo, Race, Wave One by selecting articles published in peer reviewed journals during 1991-2013 using “Pub Med” database. Inclusion and exclusion criteria were established. A data was created by tabulating: Author name, publication year, sample size, number of experimental groups, methods to evaluate canal centering ability, instrument cross section, taper, tip design, rake angle, mean and standard deviation. The data generated was subjected to meta-analysis. Results: Maximum studies were found to be conducted on mesiobuccal canal of mandibular 1st molar with curvature ranging from 15-60°. The difference in canal centering ability of different rotary cutting Ni-Ti instruments was not statistically significant. Conclusion: All endodontic rotary cutting Ni-Ti instruments are capable of producing centered preparations. Protaper depicted the best centering ability. Computed tomography is an effective method of evaluating canal centering ability.
Collapse
Affiliation(s)
- Mohan Gundappa
- Department of Conservative Dentistry and Endodontics, Teerthanker Mahaveer Dental College, Moradabad, Uttar Pradesh, India
| | - Rashmi Bansal
- Department of Conservative Dentistry and Endodontics, Teerthanker Mahaveer Dental College, Moradabad, Uttar Pradesh, India
| | - Sarvesh Khoriya
- Department of Conservative Dentistry and Endodontics, Teerthanker Mahaveer Dental College, Moradabad, Uttar Pradesh, India
| | - Ranjana Mohan
- Department of Periodontics, Teerthanker Mahaveer Dental College, Moradabad, Uttar Pradesh, India
| |
Collapse
|
15
|
Bürklein S, Mathey D, Schäfer E. Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals. Int Endod J 2014; 48:774-81. [DOI: 10.1111/iej.12375] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2014] [Accepted: 08/20/2014] [Indexed: 11/29/2022]
Affiliation(s)
- S. Bürklein
- Central Interdisciplinary Ambulance in the School of Dentistry; University of Münster; Münster Germany
| | - D. Mathey
- Department of Operative Dentistry; University of Münster; Münster Germany
| | - E. Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry; University of Münster; Münster Germany
| |
Collapse
|
16
|
Giannastasio D, Rosa RAD, Peres BU, Barreto MS, Dotto GN, Kuga MC, Pereira JR, Só MVR. Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software. J Appl Oral Sci 2014; 21:468-74. [PMID: 24212994 PMCID: PMC3881847 DOI: 10.1590/1679-775720130229] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2013] [Accepted: 08/15/2013] [Indexed: 11/21/2022] Open
Abstract
OBJECTIVE This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. MATERIAL AND METHODS Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. RESULTS The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). CONCLUSION Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.
Collapse
Affiliation(s)
- Daiana Giannastasio
- Department of Endodontics, Pontifical Catholic University of Rio Grande do Sul, Porto AlegreRS, Brazil
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Arora A, Taneja S, Kumar M. Comparative evaluation of shaping ability of different rotary NiTi instruments in curved canals using CBCT. J Conserv Dent 2014; 17:35-9. [PMID: 24554858 PMCID: PMC3915383 DOI: 10.4103/0972-0707.124127] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Revised: 09/09/2013] [Accepted: 10/17/2013] [Indexed: 11/29/2022] Open
Abstract
Aim: The aim of this study was to compare the canal transportation, canal centering ability, and time taken for preparation of curved root canals after instrumentation with ProFile GT Series X (GTX) files, Revo-S files, twisted files, and Mtwo files by using cone-beam computed tomography (CBCT). Materials and Methods: Forty mesiobuccal canals of mandibular molars with an angle of curvature ranging from 20 to 40 were divided according to the instrument used in canal preparation into four groups of 10 samples each: GTX (group I), Revo-S (group II), twisted file (group III), and Mtwo (group IV). The teeth were instrumented according to manufacturer's guidelines, with all groups being prepared to size 30, 0.06 taper master apical file. Canals were scanned using an i-CAT CBCT scanner (Imaging Science International, Hatfield, PA, USA) before and after preparation to evaluate the transportation and centering ratio at 3 mm, 5 mm, 7 mm, 9 mm, and 11 mm from the apex. The data collected were evaluated using one-way analysis of variance (ANOVA) with Tukey's honestly significant difference (HSD) test. Results: Twisted file system showed significantly least canal transportation and highest canal centering ability values as compared to GTX, Revo-S, and Mtwo file systems. Overall, GTX, Revo-S, and Mtwo showed comparable results with respect to canal transportation and centering ability. Conclusion: The innovative method of manufacturing the TF system resulted in superior shaping ability in curved canals, with the instruments remaining more centered and producing less canal transportation than GTX, Revo-S, and Mtwo file systems.
Collapse
Affiliation(s)
- Anshul Arora
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Delhi-Merrut Road, Ghaziabad, Uttar Pradesh, India
| | - Sonali Taneja
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Delhi-Merrut Road, Ghaziabad, Uttar Pradesh, India
| | - Mohit Kumar
- Department of Conservative Dentistry and Endodontics, I.T.S Centre for Dental Studies and Research, Delhi-Merrut Road, Ghaziabad, Uttar Pradesh, India
| |
Collapse
|
18
|
Flores CB, Montagner F, Gomes BPFA, Dotto GN, da Silva Schmitz M. Comparative assessment of the effects of Gates-Glidden, Largo, LA-Axxess, and New Brazilian Drill CPdrill on coronal pre-enlargement: cone-beam computed tomographic analysis. J Endod 2013; 40:571-4. [PMID: 24666914 DOI: 10.1016/j.joen.2013.08.028] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 08/24/2013] [Accepted: 08/28/2013] [Indexed: 10/26/2022]
Abstract
INTRODUCTION The removal of dentin interferences from the cervical third of root canals is essential for their correct cleaning and shaping and to facilitate access of endodontic instruments to the critical apical region. In mandibular molars, the concavity observed in the furcation area reduces dentin thickness, making this region more susceptible to perforation. The present ex vivo study used cone-beam computed tomographic imaging to compare 3 rotary burs with a new rotary bur recently launched in Brazil (ie, CPdrill; Helse Industry and Commerce Ltda, Santa Rosa, São Paulo, Brazil) regarding the amount of dentin removal from the distal wall of the mesial root of mandibular first molars. METHODS A total of 40 root canals were selected and randomly divided into 4 groups for cervical preparation: Gates-Glidden burs #2 and #3 (Dentsply Maillefer, Ballaigues, Switzerland), Largo burs #1 and #2 (Dentsply Maillefer), LA-Axxess burs #1 and #2 (SybronEndo, Glendora, CA), and CPdrill burs (1-size only). Dentin thickness in the distal wall of mesial canals at 2 mm from the furcation was measured using I-CATvision software before and after cervical preparation. RESULTS There was no statistically significant difference between groups regarding residual dentin thickness after instrumentation with the drills (P = .684). CONCLUSIONS It was concluded that CPdrill is safe for use in cervical preparation of the mesial root of mandibular first molars because it did not promote excessive dentin removal on distal walls.
Collapse
Affiliation(s)
| | - Francisco Montagner
- Endodontic Division, Department of Conservative Dentistry, Federal University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - Brenda P F A Gomes
- Endodontic Division, Piracicaba Dental School, State University of Campinas, Piracicaba, São Paulo, Brazil
| | - Gustavo Nogara Dotto
- Radiology Division, Department of Stomatology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| | - Marcia da Silva Schmitz
- Endodontic Division, Department of Stomatology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
| |
Collapse
|
19
|
Silva e Souza PAR, das Dores RSE, Tartari T, Pinheiro TPS, Tuji FM, Silva e Souza MH. Effects of sodium hypochlorite associated with EDTA and etidronate on apical root transportation. Int Endod J 2013; 47:20-5. [PMID: 23710836 DOI: 10.1111/iej.12118] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Accepted: 04/03/2013] [Indexed: 11/30/2022]
Abstract
AIM To evaluate the influence of sodium hypochlorite associated with EDTA and etidronate on apical root transportation. METHODOLOGY Forty-five roots of human mandibular molars with curvatures of 15-25° were embedded in acrylic resin to allow standardized angulation of the initial and final radiographs. The pre-instrumentation radiographs of the mesiobuccal canal of each root were taken using a radiograph digital sensor with a size 15 K-file in the canal. The canals were prepared with the ProTaper Universal system (Dentsply Maillefer, Ballaigues, Switzerland), using one of the following irrigation regimens during the instrumentation (n = 15): G1 - irrigation with 20 mL of saline solution (control); G2 - alternating irrigation with 2.5% hypochlorite solution (NaOCl) (15 mL); and 17% ethylenediaminetetraacetic acid (EDTA) (5 mL). During instrumentation, the canal was filled with NaOCl and then between each exchange of instrument filled with EDTA for 1 min, and G3 - irrigation with 20 mL of 5% NaOCl and 18% etidronate solution (HEBP) mixed in equal parts. The postinstrumentation radiographs were made with a F3 instrument in the canal. The images were magnified and superposed with Adobe Photoshop software (Adobe Systems, Mountain View, CA, USA). Apical transportation was determined with AutoCAD 2012 software (Autodesk Inc., San Rafael, CA, USA) by measuring the distance in millimetres between the tips of the instruments. The results were subjected to the nonparametric statistical Kruskal-Wallis test (α < 0.05). RESULTS The median transportation and interquartile range values were 0.00 ± 0.05 for G1, 0.08 ± 0.23 for G2 and 0.13 ± 0.14 for G3. Comparison between groups showed that apical transportation in G3 was significantly greater than in G1 (P < 0.05). CONCLUSION The use of NaOCl associated with etidronate increased apical transportation in the canals of extracted teeth.
Collapse
Affiliation(s)
- P A R Silva e Souza
- Department of Endodontics, Dental School, Federal University of Pará, Belém, Brazil
| | | | | | | | | | | |
Collapse
|
20
|
Baratieri C, Canongia ACP, Bolognese AM. Relationship between maxillary canine intra-alveolar position and maxillary incisor angulation: a cone beam computed tomography study. Braz Dent J 2011; 22:146-50. [DOI: 10.1590/s0103-64402011000200010] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2011] [Accepted: 03/02/2011] [Indexed: 11/22/2022] Open
Abstract
The aims of the present study were to evaluate the angulation and inclination of permanent maxillary incisors and to correlate the results to the intra-alveolar permanent maxillary canine position during mixed dentition, using cone beam computed tomography (CBCT). The subjects were 30 children aged 7 to 10 years in the inter-transitory period of mixed dentition (permanent incisors and first molars erupted; primary canines, first and second molars erupted; and permanent canines intraosseous). The CBCT scans were obtained and, using the Dolphin Imaging® software - version 11.0, 3D images were reconstructed and the measurements were performed. The angulation of the right and left lateral and central maxillary incisors was measured in relation to the sagittal plane and their inclination was measured in relation to the coronal plane. The intra-alveolar height of the right and left maxillary canines was measured from the cusp tip to the axial plane. Pearson's correlation at 5% significance level showed positive correlation between the canine height and the lateral incisor angulation. It was concluded that the intra-alveolar position of the maxillary canines has a direct influence on the angulation of maxillary incisors, especially the lateral incisors.
Collapse
|
21
|
Baratieri C, Alves Jr M, Sant’anna EF, Nojima MDCG, Nojima LI. 3D mandibular positioning after rapid maxillary expansion in Class II malocclusion. Braz Dent J 2011; 22:428-34. [DOI: 10.1590/s0103-64402011000500014] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study investigated, using cone beam computed tomography (CBCT), the spatial mandibular positioning after rapid maxillary expansion (RME) in Class II Division 1 malocclusion. This prospective study evaluated 17 children (mean initial age 10.36 years old) presenting Class II, Division 1 malocclusion and skeletal maxillary constriction that underwent to RME Haas’ protocol. CBCT was performed before treatment (T1), immediately after the stabilization of expander screw (T2) and after the retention period of 6 months (T3). The scans were managed in Dolphin Imaging® 11.0 software, where landmarks (right and left condylion, right and left gonion, and menton) were positioned and measured in relation to sagittal, coronal and axial plane to verify, respectively, transverse, anteroposterior and vertical displacement of the mandible. Paired Student’s t-test was used to identify significant differences (p<0.05) between T1 and T2, T2 and T3, and T1 and T3. After RME, right and left gonion moved downward (1.11 mm and 0.89 mm) and menton displaced downward (1.90 mm) and backward (1.50 mm). During the retention period, only anteroposterior displacement was significant, with the right and left gonion (0.97 mm and 1.26 mm) and the menton (2.29 mm) moving forward. Three-dimensional assessment of the mandible in Class II Division 1 patients subjected to RME showed a transitory backward and downward mandibular positioning, without any lateral displacement. The 6-month retention period allowed the mandible shifting significantly forward, exhibiting a more anterior position compared with the initial condition, even remaining in a more downward direction.
Collapse
|