1
|
Yuan D, Li L, Zhang Y, Qi K, Zhang M, Zhang W, Lyu P, Zhang Y, Gao J, Liu J. Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay. Eur J Radiol 2023; 168:111142. [PMID: 37832195 DOI: 10.1016/j.ejrad.2023.111142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 09/27/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023]
Abstract
PURPOSE To compare the contrast media opacification of head and neck CT angiography (CTA) between conventional fixed trigger delay and individualized post-trigger delay (PTD). METHODS In this prospective study (April-October 2022), 196 consecutive participants were randomly divided into two groups to perform head and neck CTA in bolus tracking with either an individualized PTD (Group A) or a fixed 4-second PTD (Group B). All CT and contrast media protocol parameters were consistent between the two groups. One reader evaluated objective image quality, while two readers rated subjective image quality. Objective image quality was compared between groups via two-sample t-test, while the subjective ratings were compared with chi-square analysis. RESULTS Participants' clinical information including sex, age, weight, body weight index (BMI), and heart rate were not statistically different between two groups (all p > 0.05). Individualized PTD ranging from 3.5 to 7.9 s (average 5.6 s), which is shorter than fixed delays (p < 0.05). Both readers rated better subjective image quality for the Group A (p < 0.05). The mean vessel enhancement was significantly higher in Group A in all vessels (all p < 0.05). CONCLUSIONS Compared to the fixed post-trigger delay in bolus tracking technique, individualized post-trigger delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality for head and neck CT angiography.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Linfeng Li
- Siemens Healthineers GmbH, Forchheim, Germany
| | - Yicun Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Ke Qi
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Mengyuan Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Weiting Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China.
| |
Collapse
|