1
|
Rajkumar DS, Padmanaban R. Impact of bisphenol A and analogues eluted from resin-based dental materials on cellular and molecular processes: An insight on underlying toxicity mechanisms. J Appl Toxicol 2024. [PMID: 38711185 DOI: 10.1002/jat.4605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 02/16/2024] [Accepted: 03/11/2024] [Indexed: 05/08/2024]
Abstract
Dental resin systems, used for artificial replacement of teeth and their surrounding structures, have gained popularity due to the Food and Drug Administration's (FDA) recommendation to reduce dental amalgam use in high-risk populations and medical circumstances. Bisphenol A (BPA), an endocrine-disrupting chemical, is an essential monomer within dental resin in the form of various analogues and derivatives. Leaching of monomers from resins results in toxicity, affecting hormone metabolism and causing long-term health risks. Understanding cellular-level toxicity profiles of bisphenol derivatives is crucial for conducting toxicity studies in in vivo models. This review provides insights into the unique expression patterns of BPA and its analogues among different cell types and their underlying toxicity mechanisms. Lack of a consistent cell line for toxic effects necessitates exploring various cell lines. Among the individual monomers, BisGMA was found to be the most toxic; however, BisDMA and BADGE generates BPA endogenously and found to elicit severe adverse reactions. In correlating in vitro data with in vivo findings, further research is necessary to classify the elutes as human carcinogens or xenoestrogens. Though the basic mechanisms underlying toxicity were believed to be the production of intracellular reactive oxygen species and a corresponding decline in glutathione levels, several underlying mechanisms were identified to stimulate cellular responses at low concentrations. The review calls for further research to assess the synergistic interactions of co-monomers and other components in dental resins. The review emphasizes the clinical relevance of these findings, highlighting the necessity for safer dental materials and underscoring the potential health risks associated with current dental resin systems.
Collapse
Affiliation(s)
- Divya Sangeetha Rajkumar
- Immunodynamics & Interface Laboratory, Centre of Advanced Study in Crystallography and Biophysics, University of Madras, Chennai, India
| | - Rajashree Padmanaban
- Immunodynamics & Interface Laboratory, Centre of Advanced Study in Crystallography and Biophysics, University of Madras, Chennai, India
| |
Collapse
|
2
|
Taghvaei N, Ghavami-Lahiji M, Evazalipour M, Tayefeh Davalloo R, Zamani E. Ion release, biocompatibility, and bioactivity of resin-modified calcium hydroxide cavity liners. BMC Oral Health 2023; 23:1034. [PMID: 38129851 PMCID: PMC10740215 DOI: 10.1186/s12903-023-03723-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Accepted: 11/28/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND The placement of liners near the pulp area is essential for therapeutic effects and maintaining pulp health while stimulating the formation of tertiary dentin. This in vitro study aimed to evaluate the calcium release, pH, biocompatibility, solubility, and bioactivity of three resin-modified calcium hydroxide cavity liners. METHODS The disc specimens of each cavity liner were prepared using polyethylene molds of 7 mm in diameter and 2 mm in height (n = 10). Three light-cure liners evaluated include Ultra-Blend Plus (UB), Base-it (BI), and Master Dent (MD). The samples were then immersed in flasks containing 10 mL of distilled water. Calcium ion release, pH, and solubility were evaluated in two weeks of incubation. The cytotoxicity of extracts adjacent to the specimens was evaluated by MTT assay using NIH/3T3 cells after 1, 3, and 7 days of incubation. The ability to induce the nucleation of calcium phosphates (CaPs) after 28-day immersion in a simulated body fluid was investigated by SEM-EDX analysis. Statistical analysis was performed using ANOVA, Kruskal-Wallis, and repeated measures tests at the significant level of 0.05. RESULTS There was a significant difference in the release of calcium ions among the three liners investigated on days 1, 7, and 14 (p < 0.05). UB liners exhibited a significantly higher amount of calcium release than the other two liners, followed by BI, and MD. On day 1, there was no significant difference in the average pH among the three liners. However, after day 7, the MD liner showed a significant decrease in pH compared to the other two liners. BI liner demonstrated the highest level of biocompatibility, followed by the MD and UB liners. UB showed a high calcium release, solubility with no alkalizing activity, and the formation of more mature Ca-rich apatite deposits than the other two liners. CONCLUSION Based on the results of this study, the cavity liner material's performance is material dependent. It can impact ion release, biocompatibility, and bioactivity which are important factors to consider in clinical practice. Further studies are needed to investigate the long-term effects of different liner materials on oral tissues.
Collapse
Affiliation(s)
- Nastaran Taghvaei
- Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Mehrsima Ghavami-Lahiji
- Department of Restorative Dentistry, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
| | - Mehdi Evazalipour
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Guilan University of Medical Sciences, Rasht, Iran
| | - Reza Tayefeh Davalloo
- Department of Restorative Dentistry, Dental Sciences Research Center, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Ehsan Zamani
- Department of Pharmacology and Toxicology, School of Pharmacy, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
3
|
Bajantri P, Rodrigues SJ, Kabekkodu SP, Bajaj A, Hegde P, Mukherjee S, Saldanha S, Mandatheje M, Shetty B T, Pai UY, Sales A, Kamath V. Cytotoxicity of dental cement on soft tissue associated with dental implants at different time intervals. F1000Res 2023; 12:1342. [PMID: 38826571 PMCID: PMC11140311 DOI: 10.12688/f1000research.140071.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/08/2023] [Indexed: 06/04/2024] Open
Abstract
Background To investigate and compare the effect of four commercially used dental cement at 24 hours, 48 hours,72 hours (h) and 6 days on the cellular response of human gingival fibroblast (HGF). Methods 3 cement pellet samples were made for each 4-test cement (n=12). The cement used for this study were zinc phosphate (ZP), zinc oxide non-eugenol (ZOE), RelyX U200 (RU200), and glass ionomer cement (GIC). The cytotoxicity of peri-implant tissues was investigated using one commercial cell line. All processing was done following International Organization for Standardization (ISO) methods 10993-5 and 10993-12 (MTT assay Test). Cell cultures without dental cement were considered as control. Standard laboratory procedures were followed to permit cell growth and confluence over 48 hrs after sub-cultivation. Before being subjected to analysis, the cells were kept in direct contact with the cement samples for the suggested time period. To validate the results the specimens were tested three times each. Cell death and inhibition of cell growth were measured quantitatively. Results were analyzed using 1-way ANOVA (a=0.05) followed by Tukey B post hoc test. Results The study showed the dental cement test material was cytotoxic. ZOE, ZP, GIC, and RU200 were cytotoxic in decreasing order, respectively, significantly reducing cell viability after exposure to HGF (p <0.001). Conclusions Within the limitations of this in-vitro cellular study, results indicated that HGF were vulnerable to the test the dental cement. The highest cytotoxicity was observed in ZOE, followed by ZP, GIC, and RU200.
Collapse
Affiliation(s)
- Prashanth Bajantri
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Shobha J. Rodrigues
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Shama Prasada Kabekkodu
- Cell and Molecular Biology, Manipal Academy of Higher Education Manipal, Manipal, Karnataka, 576104, India
| | - Akshar Bajaj
- Department of Biomaterials and Restorative Sciences, Henry M Goldman School of Dental Medicine Boston University, United States Of America, United States Of America, USA
| | - Puneeth Hegde
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Sandipan Mukherjee
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Sharon Saldanha
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Mahesh Mandatheje
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Thilak Shetty B
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Umesh Y. Pai
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Ann Sales
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Vignesh Kamath
- Department of Prosthodontics and Crown and Bridge, Manipal College of Dental Sciences, Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| |
Collapse
|
4
|
Bajantri P, Rodrigues SJ, Kabekkodu SP, Bajaj A, Hegde P, Mukherjee S, Saldanha S, Mandatheje M, Shetty B T, Pai UY, Sales A, Kamath V. Cytotoxicity of dental cement on soft tissue associated with dental implants at different time intervals. F1000Res 2023; 12:1342. [DOI: 10.12688/f1000research.140071.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
Background: To investigate and compare the effect of four commercially used dental cement at 24 hours, 48 hours,72 hours (h) and 6 days on the cellular response of human gingival fibroblast (HGF). Methods: 3 cement pellet samples were made for each 4-test cement (n=12). The cement used for this study were zinc phosphate (ZP), zinc oxide non-eugenol (ZOE), RelyX U200 (RU200), and glass ionomer cement (GIC). The cytotoxicity of peri-implant tissues was investigated using one commercial cell line. All processing was done following International Organization for Standardization (ISO) methods 10993-5 and 10993-12 (MTT assay Test). Cell cultures without dental cement were considered as control. Standard laboratory procedures were followed to permit cell growth and confluence over 48 hrs after sub-cultivation. Before being subjected to analysis, the cells were kept in direct contact with the cement samples for the suggested time period. To validate the results the specimens were tested three times each. Cell death and inhibition of cell growth were measured quantitatively. Results were analyzed using 1-way ANOVA (a=0.05) followed by Tukey B post hoc test. Results: The study showed the dental cement test material was cytotoxic. ZOE, ZP, GIC, and RU200 were cytotoxic in decreasing order, respectively, significantly reducing cell viability after exposure to HGF (p <0.001). Conclusions: Within the limitations of this in-vitro cellular study, results indicated that HGF were vulnerable to the test the dental cement. The highest cytotoxicity was observed in ZOE, followed by ZP, GIC, and RU200.
Collapse
|
5
|
Martinez-Gonzalez M, Fidalgo-Pereira RC, Torres O, Silva F, Henriques B, Özcan M, Souza JCM. Toxicity of resin-matrix cements in contact with fibroblast or mesenchymal cells. Odontology 2023; 111:310-327. [PMID: 36370322 DOI: 10.1007/s10266-022-00758-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Accepted: 10/12/2022] [Indexed: 11/13/2022]
Abstract
The main aim of this study was to perform an integrative review on the toxic effects of resin-matrix cements and their products in contact with fibroblasts or mesenchymal cells. A bibliographic search was performed on PubMed using the following search terms: "cytotoxicity" AND "fibroblast" OR "epithelial" OR "mesenchymal" AND "polymerization" OR "degree of conversion" OR "methacrylate" OR "monomer" AND "resin cement" OR "resin-based cement". The initial search in the available database yielded a total of 277 articles of which 21 articles were included in this review. A decrease in the viability of mouse fibroblasts ranged between 13 and 15% that was recorded for different resin-matrix cements after light curing exposure for 20 s. The viability of human fibroblasts was recorded at 83.11% after light curing for 20 s that increased up to 90.9% after light curing exposure for 40 s. Most of the studies linked the highest toxicity levels when the cells were in contact with Bis-GMA followed by UDMA, TEGDMA and HEMA. Resin-matrix cements cause a cytotoxic reaction when in contact with fibroblasts or mesenchymal cells due to the release of monomers from the polymeric matrix. The amount of monomers released from the resin matrix and their cytotoxicity depends on the polymerization parameters.
Collapse
Affiliation(s)
| | - Rita C Fidalgo-Pereira
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra PRD, Portugal
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505, Viseu, Portugal
| | - Orlanda Torres
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra PRD, Portugal
| | - Filipe Silva
- Center for Micro Electro Mechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal
| | - Bruno Henriques
- Center for Micro Electro Mechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal
- Ceramic and Composite Materials Research Group (CERMAT), Federal University of Santa Catarina (UFSC), Campus Trindade, Florianópolis, SC, 88040-900, Brazil
| | - Mutlu Özcan
- Division of Dental Biomaterials, Clinic of Reconstructive Dentistry, Center of Dental Medicine, University of Zurich, 8032, Zurich, Switzerland
| | - Júlio C M Souza
- University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra PRD, Portugal.
- Center for Micro Electro Mechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058, Guimarães, Portugal.
- Associate Laboratory (LABBELS), University of Minho, 4710-057, Guimarães, Braga, Portugal.
| |
Collapse
|
6
|
Influence of surface treatment and curing mode of resin composite cements on fibroblast behavior. Head Face Med 2022; 18:18. [PMID: 35690829 PMCID: PMC9188230 DOI: 10.1186/s13005-022-00323-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 05/23/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Human gingival fibroblast (HGF-1) cells in the connective tissue provide an effective barrier between the alveolar bone and the oral environment. Cement margins of restorations with intrasulcular preparation or cemented implant restorations are in contact with HGF cells. However, it is unknown to what extend the cement surface finish affects the behavior of HGF cells. The purpose of this study was to compare the behavior of HGF-1 cells in contact with two different resin composite cements with three different surface treatments after light-curing and autopolymerization, respectively. METHODS Disks of one adhesive (Multilink Automix, Ivoclar Vivadent [MLA]) and one self-adhesive (RelyX Unicem 2 Automix, 3 M [RUN]) resin composite cement were either light-cured or autopolymerized. Specimen surfaces were prepared with the oxygen inhibition layer intact, polished with P2500-grit silicon carbide paper or treated with a scaler. Cells were cultivated on the specimens for 24 h. Viability assay was performed, and cell morphology was examined with scanning electron microscopy. Additionally, roughness parameters of the specimen were analyzed with a 3D laser scanning microscope. Three-way ANOVA was applied to determine the effect of cement material, curing mode and surface treatment (a = 0.05). RESULTS Overall, cement material (p = 0.031), curing mode (p = 0.001), and surface treatment (p < 0.001) significantly affected relative cell viability of HGF. The autopolymerized specimen with the oxygen inhibition layer left intact displayed the lowest relative cell viability (MLA 25.7%, RUN 46.6%). Removal of the oxygen inhibition layer with a scaler increased cell viability but also resulted in higher surface roughness values. CONCLUSIONS HGF cell viability is affected by the surface treatment and the curing mode. The oxygen inhibition layer is an inhibitory factor for the viability of HGF cells. Autopolymerization enhances the cytotoxic potential of the oxygen inhibition layer.
Collapse
|
7
|
Ragain JC, Brodine BA, Zheng Q, Blen BJ, Garcia-Godoy F, Zhang YH. Effects of curing lights on human gingival epithelial cell proliferation. J Am Dent Assoc 2021; 152:260-268. [PMID: 33637301 DOI: 10.1016/j.adaj.2020.12.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 11/20/2020] [Accepted: 12/18/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND Light-emitting diode (LED) and quartz-tungsten-halogen (QTH) curing lights are used commonly in clinics. The aim of this study was to assess the effect of these lights on the proliferation of human gingival epithelial cells. METHODS Smulow-Glickman (S-G) cells were exposed to a VALO LED (Ultradent) or an XL3000 QTH (3M ESPE) light at 1 millimeter or 6 mm distance for 18, 39, 60, and 120 seconds. Untreated and Triton X-100 treated cells were used as controls. At 24, 48, and 72 hours after light exposure, cell proliferation was evaluated via a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. RESULTS The authors first evaluated the performances of these 2 lights. Both LED and QTH lights generated heat. The LED light generated less heat than the QTH light and could save approximately two-thirds of the curing time. When used for 18 seconds at a 6 mm distance, the LED light did not inhibit the proliferation of S-G cells. However, if the exposure time was longer (for example, 39, 60, or 120 seconds), the LED light inhibited cell proliferation. The inhibitory effect increased when the exposure time was increased to 39, 60, or 120 seconds. The QTH light did not inhibit S-G cell proliferation if the exposure time was less than 120 seconds. CONCLUSIONS Prolonged exposure to a blue curing light (both LED and QTH) inhibits the proliferation of gingival epithelial cells and may cause damages to oral soft tissues. PRACTICAL IMPLICATIONS In dental practices, a balance should be struck in consideration of curing time not only to cure the composites completely but also to minimize unnecessarily prolonged light exposure.
Collapse
|
8
|
Atalayin Ozkaya C, Tezel H, Armagan G, Tuzcu F, Sahbaz U, Dagci T. The effects of extended polymerization time for different resin composites on reactive oxygen species production and cell viability. J Oral Sci 2020; 63:46-49. [PMID: 33148930 DOI: 10.2334/josnusd.20-0034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
PURPOSE The present study was conducted to determine oxidative stress and cell viability after contact with resin composites polymerized for different times. METHODS Disk-shaped specimens of Admira Fusion, Ceram X One Universal, Solare x and Filtek Z550 (n = 12) were prepared, and two subgroups with polymerization times of 20 and 40 s were employed. The specimens were incubated with mouse fibroblast cells for 48 and 72 h, and changes in reactive oxygen species (ROS) production and cellular viability were determined by an assay with a cell-permeable fluorescent dye, 2',7'-dichlorodihydrofluorescein diacetate (H2DCF-DA), and the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay, respectively. RESULTS At 72 h, ROS production in the presence of Admira Fusion polymerized for 40 s was reduced relative to that in the presence of Admira Fusion polymerized for 20 s (P < 0.05). Cell viability was maximal in the Admira Fusion and Solare x groups and there was no difference relative to the control group at 48 h. Cell viability was higher in the Admira Fusion and Solare x groups polymerized for 40 s than for the same materials polymerized for 20 s at 72 h (P < 0.05). CONCLUSION Extension of the polymerizaton time has a material-specific effect and may be used as a strategy to increase the biocompability of resin composites.
Collapse
Affiliation(s)
| | - Huseyin Tezel
- Department of Restorative Dentistry, Ege University School of Dentistry
| | - Guliz Armagan
- Department of Biochemistry, Ege University Faculty of Pharmacy
| | - Fulya Tuzcu
- Department of Physiology, Ege University School of Medicine
| | - Ufuk Sahbaz
- Department of Physiology, Ege University School of Medicine
| | - Taner Dagci
- Department of Physiology, Ege University School of Medicine
| |
Collapse
|
9
|
Wang HT, Chou PC, Wu PH, Lee CM, Fan KH, Chang WJ, Lee SY, Huang HM. Physical and Biological Evaluation of Low-Molecular-Weight Hyaluronic Acid/Fe 3O 4 Nanoparticle for Targeting MCF7 Breast Cancer Cells. Polymers (Basel) 2020; 12:polym12051094. [PMID: 32403369 PMCID: PMC7285014 DOI: 10.3390/polym12051094] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 05/07/2020] [Accepted: 05/08/2020] [Indexed: 01/04/2023] Open
Abstract
Low-molecular-weight hyaluronic acid (LMWHA) was integrated with superparamagnetic Fe3O4 nanoparticles (Fe3O4 NPs). The size distribution, zeta potential, viscosity, thermogravimetric and paramagnetic properties of the LMWHA-Fe3O4 NPs were systematically examined. For cellular experiments, MCF7 breast cancer cell line was carried out. In addition, the cell targeting ability and characteristics of the LMWHA-Fe3O4 NPs for MCF7 breast cancer cells were analyzed using the thiocyanate method and time-of-flight secondary ion mass spectrometry (TOF-SIMS). The experimental results showed that the LMWHA-Fe3O4 NPs were not only easily injectable due to their low viscosity, but also exhibited a significant superparamagnetic property. Furthermore, the in vitro assay results showed that the NPs had negligible cytotoxicity and exhibited a good cancer cell targeting ability. Overall, the results therefore suggest that the LMWHA-Fe3O4 NPs have considerable potential as an injectable agent for enhanced magnetic resonance imaging (MRI) and/or hyperthermia treatment in breast cancer therapy.
Collapse
Affiliation(s)
- Hsin-Ta Wang
- School of Organic and Polymeric, National Taipei University of Technology, Taipei 10608, Taiwan; (H.-T.W.); (P.-C.C.)
| | - Po-Chien Chou
- School of Organic and Polymeric, National Taipei University of Technology, Taipei 10608, Taiwan; (H.-T.W.); (P.-C.C.)
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (W.-J.C.); (S.-Y.L.)
| | - Ping-Han Wu
- Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan;
| | - Chi-Ming Lee
- Core Facility Center, Office of Research and Development, Taipei Medical Universitry, Taipei 11031, Taiwan;
| | - Kang-Hsin Fan
- Dental Department, En Chu Kong Hospital, New Taipei City 23742, Taiwan;
| | - Wei-Jen Chang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (W.-J.C.); (S.-Y.L.)
| | - Sheng-Yang Lee
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (W.-J.C.); (S.-Y.L.)
| | - Haw-Ming Huang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei 11031, Taiwan; (W.-J.C.); (S.-Y.L.)
- Graduate Institute of Biomedical Optomechatronics, College of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
- Correspondence: ; Tel.: +886-291-937-9783
| |
Collapse
|
10
|
Rohr N, Bertschinger N, Fischer J, Filippi A, Zitzmann NU. Influence of Material and Surface Roughness of Resin Composite Cements on Fibroblast Behavior. Oper Dent 2020; 45:528-536. [DOI: 10.2341/19-113-l] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/31/2019] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
A well-polished cement surface increases the viability and spreading of gingival fibroblasts. The tested resin composite cements did not reveal any cytotoxic effects.
SUMMARY
Objective: This in vitro study aimed to investigate the effect of cement type and roughness on the viability and cell morphology of human gingival fibroblasts (HGF-1).
Methods and Materials: Discs of three adhesive (Panavia V5 [PV5], Multilink Automix [MLA], RelyX Ultimate [RUL] and three self-adhesive (Panavia SA plus [PSA], SpeedCem plus [SCP], RelyX Unicem [RUN]) resin composite cements were prepared with three different roughnesses using silica paper grit P180, P400, or P2500. The cement specimens were characterized by surface roughness and energy-dispersive X-ray spectroscopic mapping. A viability assay was performed after 24 hours of incubation of HGF-1 cells on cement specimens. Cell morphology was examined with scanning electron microscopy.
Results: The roughness of the specimens did not differ significantly among the different resin composite cements. Mean Ra values for the three surface treatments were 1.62 ± 0.34 μm for P180, 0.79 ± 0.20 μm for P400, and 0.17 ± 0.08 μm for P2500. HGF-1 viability was significantly influenced by the cement material and the specimens’ roughness, with the highest viability for PSA ≥ RUN = MLA ≥ SCP = PV5 > RUL (p<0.05) and for P2500 = P400 > P180 (p<0.001). Cell morphology did not vary among the materials but was affected by the surface roughness.
Conclusion: The composition of resin composite cements significantly affects the cell viability of HGF-1. Smooth resin composite cement surfaces with an Ra of 0.2–0.8 μm accelerate flat cell spreading and formation of filopodia.
Collapse
|
11
|
Klein-Junior CA, Zimmer R, Borghetti DLB, Portella FF, Abich FC, Marinowic DR, Hosaka K, Reston EG. Hot air stream reduces cytotoxicity of light-cured calcium hydroxide based cements. J Clin Exp Dent 2020; 12:e215-e219. [PMID: 32190190 PMCID: PMC7071541 DOI: 10.4317/jced.56590] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Accepted: 01/08/2020] [Indexed: 01/09/2023] Open
Abstract
Background The light-cured calcium hydroxide based cements have incomplete polymerization and unconverted monomers can cause pulp cell damage. The aim of this study was to evaluate the influence of a warm and hot air stream on the cytotoxicity of light-cured calcium hydroxide based cements.
Material and Methods The materials Dycal (conventional cement), Biocal, Hidrox-Cal, and Ultra-Blend Plus (light-cured calcium hydroxide cements) were submitted to cytotoxicity analysis after polymerization, without vs. with previous heat treatment with a warm (37°C) and a hot (60°C) air stream. Following polymerization, cements were maintained in culture medium for 24 hours and 7 days, and subjected to the MTT test. Data were analyzed using analysis of variance (ANOVA) followed by post-hoc Student-Newman-Keuls (<0.05).
Results The results indicated significant differences between the materials according to their composition, i.e., light-cured cements treated with a jet of warm air showed similar cytotoxicity levels to those observed for conventional cement, suggesting that they may be considered alternatives in cases requiring pulp-capping treatment.
Conclusions Application of a hot air stream reduced cytotoxicity of materials tested. Key words:Dental pulp capping, dental cements, calcium hydroxide, cell survival.
Collapse
Affiliation(s)
- Celso-Afonso Klein-Junior
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (ULBRA), Cachoeira do Sul, Rio Grande do Sul, Brazil
| | - Roberto Zimmer
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (ULBRA), Canoas, Rio Grande do Sul, Brazil
| | - Diana-Lina-Bronca Borghetti
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (ULBRA), Canoas, Rio Grande do Sul, Brazil
| | - Fernando-Freitas Portella
- Institute of Health Sciences, Universidade Feevale, ERS-239 2755, Novo Hamburgo, Rio Grande do Sul, Brazil
| | - Flávia-Carolina Abich
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (ULBRA), Cachoeira do Sul, Rio Grande do Sul, Brazil
| | - Daniel-Rodrigo Marinowic
- Neuroscience Department, Brain Institute, Neuroscience Laboratory, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - Keiichi Hosaka
- Department of Oral Health Science, School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan
| | - Eduardo-Galia Reston
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil (ULBRA), Canoas, Rio Grande do Sul, Brazil
| |
Collapse
|
12
|
Oguz EI, Hasanreisoglu U, Uctasli S, Özcan M, Kiyan M. Effect of various polymerization protocols on the cytotoxicity of conventional and self-adhesive resin-based luting cements. Clin Oral Investig 2019; 24:1161-1170. [PMID: 31327082 DOI: 10.1007/s00784-019-02980-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 06/20/2019] [Indexed: 11/26/2022]
Abstract
OBJECTIVES This study evaluated the cytotoxicity of resin-based luting cements on fibroblast cells using different polymerization protocols. MATERIALS AND METHODS Two conventional dual-polymerized (RelyX ARC, VariolinkN) and two self-adhesive resin cements (RelyX Unicem, Multilink Speed) specimens were polymerized using four different polymerization protocols: (a) photo-polymerization with direct light application, (b) photo-polymerization over ceramic and (c) resin nano-ceramic discs and (d) auto-polymerization. The specimens were then assigned to four groups to test cytotoxicity at 0, 1, 2 and 7 preincubation days (n = 5). MTT test was performed using NIH/3T3 fibroblast cells. Data were analysed using three- and one-way ANOVA. Multiple comparisons were made using Bonferroni post hoc test (p < 0.05). RESULTS The highest cytotoxic values were recorded at day 2 for conventional resin cements and at day 0 for self-adhesive resin cements. Self-adhesive resin cements showed the most cytotoxic effect at the second day, while conventional resin cements presented immediate cytotoxicity. Auto-polymerized resin specimens and especially Multilink Speed demonstrated the most cytotoxic effect regardless of the preincubation time. Cytotoxicity of cements tested reached the lowest level at day 7. Interposition of ceramic or nano-ceramic restorative material did not significantly affect the cytotoxicity of tested luting cements (p > 0.05). CONCLUSIONS Cytotoxicity of dual-polymerized resin cements was material-dependent and decreased gradually up to 7 days. Photo-polymerization plays an important role in reducing the cytotoxic effects. CLINICAL RELEVANCE When luting ceramic or resin nano-ceramic restorations of which thickness does not exceed 2 mm, the level of cytotoxicity with the tested materials is not significant. Luting of restorative materials that do not allow for light transmission such as metal-fused porcelain, clinicians should be cautious in the use of dual-polymerized conventional resin cements as only auto-polymerization of resin cements takes place under such materials.
Collapse
Affiliation(s)
- Ece Irem Oguz
- Faculty of Dentistry, Department of Prosthodontics, Ankara University, Ankara, Turkey.
| | - Ufuk Hasanreisoglu
- Faculty of Dentistry, Department of Prosthodontics, Ankara University, Ankara, Turkey
| | - Sadullah Uctasli
- Faculty of Dentistry, Department of Prosthodontics, Ankara University, Ankara, Turkey
| | - Mutlu Özcan
- Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, University of Zurich, Zurich, Switzerland
| | - Mehmet Kiyan
- Faculty of Medicine, Department of Medical Microbiology, Ankara University, Ankara, Turkey
| |
Collapse
|
13
|
In Vitro Cytotoxicity of Self-Adhesive Dual-Cured Resin Cement Polymerized Beneath Three Different Cusp Inclinations of Zirconia. BIOMED RESEARCH INTERNATIONAL 2019; 2019:7404038. [PMID: 31240222 PMCID: PMC6556254 DOI: 10.1155/2019/7404038] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Accepted: 05/02/2019] [Indexed: 12/29/2022]
Abstract
The aim of the present study was to evaluate the in vitro cytotoxicity of self-adhesive dual-cured resin cement (SADRC) polymerized beneath three different cusp inclinations of zirconia with different light curing time. A commercial SADRC (Multilink Speed) was polymerized beneath zirconia (ZrO2) with three different cusp inclinations (0°, 20°, and 30°) for 20 s or 40 s. After being stored in light-proof box for 24 h, the ZrO2-SADRC specimens were immersed in DMEM for 72 h and then we got the extract solution, cultured the human gingival fibroblasts (HGF, 8 × 103 per well) with 100% or 50% concentrations of the extract solution for 24 h, 72 h, and 120 h, respectively, and evaluated cytotoxicity of the polymerized SADRC with CCK-8 assay in optical density (OD) values, relative growth rates (RGR), and cytotoxicity grades. Statistical analysis was conducted using a two-way ANOVA followed by post hoc Student–Newman–Keuls test. The OD values varied from 0.8930 to 3.2920, the RGR varied from 33.93% to 98.68%, and the cytotoxicity grades varied from 0 to 2. There was significant difference in the OD values among the different cusp inclinations of zirconia (P < 0.001), and there was significant difference in the OD values between the different light curing times in some situations (P < 0.05). The cusp inclination of zirconia affects the in vitro cytotoxicity of SADRC. Prolonging the light curing time from 20 s to 40 s can reduce the in vitro cytotoxicity of SADRC when the cusp inclination of zirconia is smaller than 20°.
Collapse
|
14
|
Klein-Júnior CA, Zimmer R, Hentschke GS, Machado DC, Dos Santos RB, Reston EG. Effect of heat treatment on cytotoxicity of self-adhesive resin cements: Cell viability analysis. Eur J Dent 2018; 12:281-286. [PMID: 29988221 PMCID: PMC6004809 DOI: 10.4103/ejd.ejd_34_18] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Objective The aim of the study was to assess, in vitro, the influence on cytotoxicity of heat treatment applied before photopolymerization, while mixing three self-adhesive resin cements, in an NIH/3T3 fibroblast cell culture, based on cell viability measures. Methods Samples were divided into three groups: (1) no heat treatment while mixing (control), (2) 37°C, and (3) 60°C heat treatment while mixing. Cements were light-cured immediately after mixing and immersed in Dulbecco's Modified Eagle Media for the extraction of possibly uncured products after 24 h and 7 days. Cultures contained 0.5 mL of NIH/3T3 fibroblasts per well at a concentration of 0.4 × 105 cells/mL and specific extracts for each sample. Statistical Analysis Used Data were statistically analyzed with ANOVA and post hoc Student-Newman-Keuls (significance of 5%). Results Cement cytotoxicity increased with time, as shown by the higher values observed at 7 days. There was a slight difference in intragroup cytotoxicity levels between 24 h and 7 days. Heat treatment at 60°C was associated with a major decrease in cytotoxicity levels in all three groups, both at 24 h and at 7 days, with no differences among the cements. Conclusions Heat treatment at 60°C should be considered as a strategy to reduce cytotoxicity of self-adhesive resin cements, as evidenced by the results observed at 24 h and 7 days of analysis.
Collapse
Affiliation(s)
- Celso Afonso Klein-Júnior
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil, Cachoeira do Sul, Rio Grande do Sul, Brazil
| | - Roberto Zimmer
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil, Cachoeira do Sul, Rio Grande do Sul, Brazil
| | | | - Denise Cantarelli Machado
- Neuroscience Department, Brain Institute, Neuroscience Laboratory, Pontifical Catholic University of Rio Grande do Sul, Rio Grande do Sul, Brazil
| | - Rubem Beraldo Dos Santos
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil, Cachoeira do Sul, Rio Grande do Sul, Brazil
| | - Eduardo Galia Reston
- Department of Operative Dentistry, School of Dentistry, Lutheran University of Brazil, Cachoeira do Sul, Rio Grande do Sul, Brazil
| |
Collapse
|
15
|
Fonseca GS, Correia AMDO, Griza S, Villarroel M, Takeshita WM, Mendonça AAMD. Efeito da intensidade de fontes de luz e barreiras de cerâmica na microdureza de cimento resinoso dual. REVISTA DE ODONTOLOGIA DA UNESP 2015. [DOI: 10.1590/1807-2577.1083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
<title>Resumo</title><sec><title>Introdução</title><p>O cimento resinoso dual é o principal material para cimentação de cerâmicas. Contudo, fatores, como fonte de luz, podem influenciar no desempenho do cimento.</p></sec><sec><title>Objetivo</title><p>Avaliar a influência de duas fontes de luz de diferentes intensidades sobre a microdureza de um cimento resinoso quando fotoativado sob diferentes cerâmicas.</p></sec><sec><title>Material e método</title><p>Foram fotoativados 40 espécimes de cimento resinoso dual (10 mm × 1,0 mm) por meio de duas fontes de luz LED, com intensidades de 1.000 mW/cm² e 800 mW/cm² durante 40 segundos, sob cerâmicas (15 mm × 2 mm) à base de zircônia, espinélio MgAl<sub>2</sub>O<sub>4</sub> e dissilicato de lítio. No grupo controle, foi utilizada uma placa de vidro de mesma dimensão. As amostras tiveram a superfície regularizada com lixa d`água (600 e 1200). Após armazenagem a seco no escuro (24 h), foram realizadas as medidas de microdureza Vickers (HMV Shimadzu - 50g/10 segundos). Os dados foram submetidos à Anova fatorial e ao teste de Tukey com nível de significância de 5%.</p></sec><sec><title>Resultado</title><p>O cimento polimerizado apresentou valor médio de microdureza e desvio padrão para o grupo controle de 43,9±1,5 e 43,4±1,3, para as intensidades de 1.000 mW/cm<sup>2</sup> e 800 mW/cm<sup>2</sup>, respectivamente. O menor valor de microdureza do cimento foi observado para a cerâmica à base de espinélio MgAl<sub>2</sub>O<sub>4</sub>, polimerizado a 800 mW/cm², com valor de 34,3±3,3.</p></sec><sec><title>Conclusão</title><p>O tipo de cerâmica e a intensidade da fonte de luz influenciam na microdureza do cimento. A intensidade de 1.000 mW/cm<sup>2</sup> sobre as cerâmicas à base de zircônia e espinélio MgAl<sub>2</sub>O<sub>4</sub> resultaram na melhor combinação de valores de dureza do cimento.</p></sec>
Collapse
|
16
|
Dioguardi M, Perrone D, Troiano G, Laino L, Ardito F, Lauritano F, Cicciù M, Muzio LL. Cytotoxicity evaluation of five different dual-cured resin cements used for fiber posts cementation. Int J Clin Exp Med 2015; 8:9327-9333. [PMID: 26309592 PMCID: PMC4538005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 03/07/2015] [Indexed: 06/04/2023]
Abstract
Custom-cast posts and cores are usually used to treat endodontically treated teeth. However, several researches have underlined how these devices may be a much higher elastic modulus than the supporting dentine and the difference in the modulus could lead to stress concentrating in the cement lute, leading to failure. The role of the cement seems to play a fundamental role in order to transfer the strength during the chewing phases. Aim of this research is to record the rate of cytotoxicity of five different dual-cured resin cements used for fiber posts cementation. We tested the cytotoxicity of this five materials on MG63 osteoblast-like cells through two different methods: MTT ([3-4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide succinate) assay which tests for mitochondrial enzyme activity(6) and xCELLigence® system.
Collapse
Affiliation(s)
- M Dioguardi
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| | - D Perrone
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| | - G Troiano
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| | - L Laino
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| | - F Ardito
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| | - F Lauritano
- Department of Odonto-Stomatology, University of Messina University of Messina School of Dentistry ME, IT
| | - M Cicciù
- Department of Human Pathology, School of Dentistry University of Messina School of Dentistry ME, IT
| | - L Lo Muzio
- Department of Clinical and Experimental Medicine, University of Foggia FO, Italy
| |
Collapse
|
17
|
Attik GN, Gritsch K, Colon P, Grosgogeat B. Confocal time lapse imaging as an efficient method for the cytocompatibility evaluation of dental composites. J Vis Exp 2014:e51949. [PMID: 25406737 PMCID: PMC4353434 DOI: 10.3791/51949] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
It is generally accepted that in vitro cell material interaction is a useful criterion in the evaluation of dental material biocompatibility. The objective of this study was to use 3D CLSM time lapse confocal imaging to assess the in vitro biocompatibility of dental composites. This method provides an accurate and sensitive indication of viable cell rate in contact with dental composite extracts. The ELS extra low shrinkage, a dental composite used for direct restoration, has been taken as example. In vitro assessment was performed on cultured primary human gingival fibroblast cells using Live/Dead staining. Images were obtained with the FV10i confocal biological inverted system and analyzed with the FV10-ASW 3.1 Software. Image analysis showed a very slight cytotoxicity in the presence of the tested composite after 5 hours of time lapse. A slight decrease of cell viability was shown in contact with the tested composite extracts compared to control cells. The findings highlighted the use of 3D CLSM time lapse imaging as a sensitive method to qualitatively and quantitatively evaluate the biocompatibility behavior of dental composites.
Collapse
Affiliation(s)
- Ghania Nina Attik
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Lyon1;
| | - Kerstin Gritsch
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Lyon1; UFR d'Odontologie, Université Lyon1; Service de Consultations et de Traitements Dentaires, Hospices Civils de Lyon
| | - Pierre Colon
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Lyon1; UFR d'Odontologie, Université Paris Diderot; Service d'Odontologie, APHP, Hôpital Rothschild
| | - Brigitte Grosgogeat
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Lyon1; UFR d'Odontologie, Université Lyon1; Service de Consultations et de Traitements Dentaires, Hospices Civils de Lyon
| |
Collapse
|
18
|
Wegehaupt FJ, Tauböck TT, Attin T, Belibasakis GN. Influence of light-curing mode on the cytotoxicity of resin-based surface sealants. BMC Oral Health 2014; 14:48. [PMID: 24885810 PMCID: PMC4019812 DOI: 10.1186/1472-6831-14-48] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2014] [Accepted: 05/01/2014] [Indexed: 11/10/2022] Open
Abstract
Background Surface sealants have been successfully used in the prevention of erosive tooth wear. However, when multiple tooth surfaces should be sealed, the light-curing procedure is very time-consuming. Therefore, the aim of this study was to investigate whether reduced light-curing time (while maintaining similar energy density) has an influence on resin-based surface sealant cytotoxicity. Methods Bovine dentine discs were treated as follows: group 1: untreated, groups 2–5: Seal&Protect and groups 6–9: experimental sealer. Groups 2 and 6 were light-cured (VALO LED light-curing device) for 40 s (1000 mW/cm2), groups 3 and 7 for 10 s (1000 mW/cm2), groups 4 and 8 for 7 s (1400 mW/cm2) and groups 5 and 9 for 3 s (3200 mW/cm2). Later, materials were extracted in culture medium for 24 h, and released lactate dehydrogenase (LDH) activity as a measure of cytotoxicity was determined photometrically after cells (dental pulp cells and gingival fibroblasts) were exposed to the extracts for 24 h. Three independent experiments, for both sample preparation and cytotoxicity testing, were performed. Results Overall, lowest cytotoxicity was observed for the unsealed control group. No significant influence of light-curing settings on the cytotoxicity was observed (p = 0.537 and 0.838 for pulp cells and gingival fibroblasts, respectively). No significant difference in the cytotoxicity of the two sealants was observed after light-curing with same light-curing settings (group 2 vs. 6, 3 vs. 7, 4 vs. 8 and 5 vs. 9: p > 0.05, respectively). Conclusions Shortening the light-curing time, while maintaining constant energy density, resulted in no higher cytotoxicity of the investigated sealants.
Collapse
Affiliation(s)
- Florian J Wegehaupt
- Clinic for Preventive Dentistry, Periodontology and Cariology, University of Zurich, Plattenstrasse 11, 8032 Zürich, Switzerland.
| | | | | | | |
Collapse
|
19
|
Attik GN, Pradelle-Plasse N, Campos D, Colon P, Grosgogeat B. Toxicity evaluation of two dental composites: three-dimensional confocal laser scanning microscopy time-lapse imaging of cell behavior. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2013; 19:596-607. [PMID: 23635466 DOI: 10.1017/s1431927613000433] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The purpose of this study was to investigate the in vitro biocompatibility of two dental composites (namely A and B) with similar chemical composition used for direct restoration using three-dimensional confocal laser scanning microscopy (CLSM) time-lapse imaging. Time-lapse imaging was performed on cultured human HGF-1 fibroblast-like cells after staining using Live/Dead®. Image analysis showed a higher mortality rate in the presence of composite A than composite B. The viability rate decreased in a time-dependent manner during the 5 h of exposure. Morphological alterations were associated with toxic effects; cells were enlarged and more rounded in the presence of composite A as shown by F-actin and cell nuclei staining. Resazurin assay was used to confirm the active potential of composites in cell metabolism; results showed severe cytotoxic effects in the presence of both no light-curing composites after 24 h of direct contact. However, extracts of polymerized composites induced a moderate decrease in cell metabolism after the same incubation period. Composite B was significantly better tolerated than composite A at all investigated end points and all time points. The finding confirmed that the used CLSM method was sufficiently sensitive to differentiate the biocompatibility behavior of two composites based on similar methacrylate monomers.
Collapse
Affiliation(s)
- Ghania Nina Attik
- Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Université Lyon1, Villeurbanne, France.
| | | | | | | | | |
Collapse
|
20
|
Puppin-Rontani RM, Dinelli RG, de Paula AB, Fucio SBP, Ambrosano GMB, Pascon FM. In-depth polymerization of a self-adhesive dual-cured resin cement. Oper Dent 2011; 37:188-94. [PMID: 22166106 DOI: 10.2341/10-288-l] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to assess Knoop hardness at different depths of a dual-cured self-adhesive resin cement through different thicknesses of Empress Esthetic® ceramic.Flattened bovine dentin was embedded in resin. The cement was inserted into a rubber mold (0.8 x 5 mm) that was placed between two polyvinyl chloride plastic films and placed over the flat dentin and light cured by Elipar Trilight-QTH (800 mW/cm2) or Ultra-Lumelight-emitting diode (LED 5; 1585 mW/cm2) over ceramic disks 1.4 or 2 mm thick. The specimens(n=6) were stored for 24 hours before Knoop hardness (KHN) was measured. The data were submitted to analysis of variance in a factorial split-plot design and Tukey's test (a=0.05).There was significant interaction among the study factors. In the groups cured by the QTHunit, an increase in ceramic thickness resulted in reduced cement hardness values at all depths, with the highest values always being found in the center (1.4 mm, 58.1; 2 mm, 50.1)and the lowest values at the bottom (1.4 mm,23.8; 2 mm, 20.2). When using the LED unit, the hardness values diminished with increased ceramic thickness only on the top (1.4 mm,51.5; 2 mm, 42.3). In the group with the 1.4-mm-thick disk, the LED curing unit resulted in similar values on the top (51.5) and center(51.9) and lower values on the bottom (24.2).However, when the cement was light cured through the 2-mm disk, the highest hardness value was obtained in the center (51.8), followed by the top (42.3) and bottom (19.9),results similar to those obtained with the QTH curing unit (center > top > bottom). The hardness values of the studied cement at different depths were dependent on the ceramic thickness but not on the light curing units used.
Collapse
|