1
|
Molaei M, Mohammadzadeh A, Ghasemi A, Badiee M. Effect of dry and wet finishing and polishing on color change and opacity of nanofill and nanohybrid composites. BMC Oral Health 2024; 24:287. [PMID: 38419033 PMCID: PMC10903010 DOI: 10.1186/s12903-024-03944-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 01/26/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND As superior esthetic is one of the main reasons for using composite resins, it is very important to be familiar with factors and techniques affecting their optical properties and appearance. AIM The aim of this study was comparing the effect of finishing and polishing with and without water coolant, on the color change and opacity of composite resin materials. METHODS Composites used for preparing samples were Z250 (microhybrid), Z350XT (nanofilled), and Z550 (nanohybrid). Then divided into 4 groups of 5 depending on finishing and polishing technique (dry or wet) and time (immediate and after twenty-four hours). After polishing, samples were assessed using a spectrophotometer. Color change and opacity were determined. Data was analyzed using Kolmogorov-Smirnov, ANOVA and Tukey HSD tests. RESULTS Type of material at both time had a significant effect on ΔE and opacity. Our results in dry and wet technique immediately(T0) showed that the highest and lowest ΔE and opacity belong to Z350XT (p < 0.001). After Twenty-four hours (T24), opacity of Z250 in wet condition was higher than dry condition (p < 0.001). CONCLUSIONS Wet or dry technique was only effective on color in immediate polishing. Regarding opacity, technique was only effective in case of delayed polishing.
Collapse
Affiliation(s)
- Mehdi Molaei
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Anoosh Mohammadzadeh
- School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Amir Ghasemi
- Dental Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mehdi Badiee
- School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.
| |
Collapse
|
2
|
Mitwalli HA, Baras BH, Saeed SS, Xu HH, Weir MD. Testing mechanical properties and degree of conversion of resin-based composite material containing contact killing antibacterial agent in comparison with fluoride composite resin. Saudi Dent J 2024; 36:99-104. [PMID: 38375385 PMCID: PMC10874990 DOI: 10.1016/j.sdentj.2023.11.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 02/21/2024] Open
Abstract
Background A major drawback of resin composites is their tendency to accumulate microbial biofilms that can lead to secondary caries. The objective of this study was to compare the mechanical properties and the degree of conversion of commercial resin-based composite materials containing a contact-killing antibacterial agent, dimethylaminohexadecyl methacrylate (DMAHDM), at different concentrations, with a fluoride-releasing composite material. Materials and methods Four groups were tested: Tetric N Ceram composite material (G1), Tetric Evo Ceram (G2), and Tetric N Ceram with the addition of contact-killing antibacterial agent DMAHDM at concentrations of 3% (G3) and 5% (G4). The mechanical properties, including flexural strength, elastic modulus, and Vickers microhardness and the degree of conversion were investigated. Results Adding 3 % and 5 % DMAHDM resulted in flexural strength values that were comparable to Tetric Evo Ceram. Tetric N Ceram was comparable to the group containing 3 % DMAHDM (p > 0.05). However, it was significantly greater when compared to Tetric Evo Ceram (93.3 ± 9.4) and 5 % DMAHDM (p < 0.05). Both the elastic modulus and Vickers microhardness values of Tetric N Ceram were significantly higher than those of the other groups (p < 0.05). Furthermore, the elastic modulus of Tetric Evo Ceram showed similar results to groups with 3 % and 5 % DMAHDM. Nevertheless, the Vickers microhardness value is significantly higher when compared to 5 % DMAHDM (0.394 ± 0.021) (p < 0.05) while it was comparable to that of 3 % DMAHDM (0.484 ± 0.016) (p > 0.05). There was no statistically significant difference in the degree of conversion between the groups (p > 0.05). Conclusion Adding 3% DMAHDM to Tetric N Ceram resulted in flexural strength values that were similar to those of Tetric N Ceram and Tetric Evo Ceram. DMAHDM did not affect the degree of conversion of Tetric N Ceram composite.
Collapse
Affiliation(s)
- Heba A. Mitwalli
- Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
| | - Bashayer H. Baras
- Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
| | - Sara S. Saeed
- College of Dentistry, King Saud University, Riyadh 11451, Saudi Arabia
| | - Hockin H.K. Xu
- Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, MD 21201, United States
- Center for Stem Cell Biology & Regenerative Medicine, University of Maryland School of Medicine, Baltimore, MD 21201, United States
- Marlene and Stewart Greenebaum Cancer Center, University of Maryland School of Medicine, Baltimore, MD 21201, United States
| | - Michael D. Weir
- Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, MD 21201, United States
| |
Collapse
|
3
|
Eldafrawy M, Karevan Y, Nguyen JF, Mainjot A. Interblock and intrablock homogeneity of CAD-CAM composites mechanical properties. Dent Mater J 2023; 42:780-790. [PMID: 37853645 DOI: 10.4012/dmj.2023-090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
The purpose of this study was to characterize the homogeneity of the mechanical properties of commercial CAD-CAM composites between different blocks of the same material (interblock homogeneity) and within each block between the internal and external parts (intrablock homogeneity). Tetric CAD (TET); Katana Avencia (KAT); Cerasmart 270 (CER); Grandio (GRN) and Vita Enamic (ENA) were tested for flexural strength (σf), flexural modulus (Ef), flexural load energy (Ur) and hardness (HV). Results showed significant differences in interblock homogeneity of σf, Ef and Ur for TET, KAT, CER and ENA. In addition, significant differences in interblock homogeneity of HV for TET, CER and GRN were found. Moreover, significant differences in intrablock homogeneity of σf, Ef and Ur were found for KAT, CER, GRN and ENA, as well as for HV of all the tested materials except CER. Weibull modulus was highest for GRN, followed by ENA, KAT, TET then CER.
Collapse
Affiliation(s)
- Maher Eldafrawy
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU)
| | - Yousef Karevan
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
| | - Jean-François Nguyen
- Innovative Dental Materials and Interfaces Research Unit (UR 4462), Université Paris Cité
| | - Amélie Mainjot
- Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège)
- Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU)
| |
Collapse
|
4
|
Alqarni D, Nakajima M, Tagami J, Alzahrani MS, Sá-Pinto AC, Alghamdi A, Hosaka K, Alzahrani F, Alsadon OA, Alharbi RA, Almalki SS, Alzahrani AAH. Study of Streptococcus mutans in Early Biofilms at the Surfaces of Various Dental Composite Resins. Cureus 2023; 15:e38090. [PMID: 37252523 PMCID: PMC10209747 DOI: 10.7759/cureus.38090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Accepted: 04/23/2023] [Indexed: 05/31/2023] Open
Abstract
BACKGROUND Biofilm deposit on the composite restoration is a common phenomenon and bacterial growth follows the deposition. The study aims to evaluate Streptococcus mutans (S. mutans) early biofilm formation on the surfaces of various dental composite resins by using the real-time quantitative polymerase chain reaction (qPCR) technique. MATERIALS AND METHODS Thirty-two discs, where eight discs were in each group of Filtek Supreme Ultra (FSU; 3M, St. Paul, MN), Clearfil AP-X (APX; Kuraray Noritake Dental Inc., Tokyo, Japan), Beautifil II (BE2; Shofu, Inc., Kyoto, Japan), and Estelite Sigma Quick (ESQ; Tokuyama Dental, Tokyo, Japan), were fabricated and subjected to S. mutans biofilm formation in an oral biofilm reactor for 12 hours. Contact angles (CA) were measured on the freshly fabricated specimen. The attached biofilms underwent fluorescent microscopy (FM). S. mutans from biofilms were analyzed using a qPCR technique. Surface roughness (Sa) measurements were taken before and after biofilm formation. Scanning electron microscopy (SEM), including energy dispersive X-ray spectrometer (EDS) analysis, was also performed for detecting relative elements on biofilms. RESULTS The study showed that FSU demonstrated the lowest CA while APX presented the highest values. FM revealed that condensed biofilm clusters were most on FSU. The qPCR results indicated the highest S. mutans DNA copies in the biofilm were on FSU while BE2 was the lowest (p < 0.05). Sa test signified that APX was significantly the lowest among all materials while FSU was the highest (p < 0.05). SEM displayed areas with apparently glucan-free S. mutans more on BE2 compared to APX and ESQ, while FSU had the least. Small white particles detected predominantly on the biofilms of BE2 appeared to be Si, Al, and F extruded from the resin. CONCLUSION Differences in early biofilm formation onto various composite resins are dependent on the differences in material compositions and their surface properties. BE2 showed the lowest quantity of biofilm accumulation compared to other resin composites (APX, ESQ, and FSU). This could be attributed to BE2 proprieties as a giomer and fluoride content.
Collapse
Affiliation(s)
- Dhaifallah Alqarni
- Restorative and Prosthodontic Department, Almikhawah Dental Center, Al-Baha, SAU
| | - Masatoshi Nakajima
- Department of Cariology and Operative Dentistry/Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, JPN
| | - Junji Tagami
- Department of Cariology and Operative Dentistry/Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, JPN
| | - Mohammed S Alzahrani
- Restorative Dental Sciences Department, School of Dentistry, Al-Baha University, Al-Baha, SAU
| | - Ana Clara Sá-Pinto
- Department of Pediatric Dentistry and Orthodontics, School of Dentistry, Universidade Federal dos Vales do Jequitinhonha e Mucuri, Minas Gerais, BRA
| | - Ali Alghamdi
- Restorative and Prosthodontic Department, Almikhawah Dental Center, Al-Baha, SAU
| | - Keiichi Hosaka
- Department of Regenerative Dental Medicine, Graduate School of Biomedical Sciences, Tokushima University, Tokushima, JPN
| | - Fouad Alzahrani
- Pulp Biology and Endodontic Department, Al-Baha Dental Center, Al-Baha, SAU
| | - Omar A Alsadon
- Department of Dental Health, School of Applied Medical Sciences, King Saud University, Riyadh, SAU
| | - Raed A Alharbi
- Department of Laboratory Medicine, School of Applied Medical Sciences, Al-Baha University, Al-Baha, SAU
| | - Shaia S Almalki
- Department of Laboratory Medicine, School of Applied Medical Sciences, Al-Baha University, Al-Baha, SAU
| | - Abdullah Ali H Alzahrani
- Department of Dental Health, School of Applied Medical Sciences, Al-Baha University, Al-Baha, SAU
| |
Collapse
|
5
|
Kwaśny M, Polkowski J, Bombalska A. A Study on the Photopolymerization Kinetics of Selected Dental Resins Using Fourier Infrared Spectroscopy (FTIR). MATERIALS (BASEL, SWITZERLAND) 2022; 15:5850. [PMID: 36079232 PMCID: PMC9457181 DOI: 10.3390/ma15175850] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 08/19/2022] [Accepted: 08/21/2022] [Indexed: 06/15/2023]
Abstract
The aim of the presented study was a comparative analysis of the polymerization kinetics of dental resin-based composites currently used in dentistry in different environmental conditions (irradiance, activation time, layer thickness). The photopolymerization kinetics of eleven dental resins were investigated using a Woodpecker LED source. The DC was measured by FTIR in transmission mode and attenuated total reflection (ATR) from 5 s to 7 days. In the transmission mode, the spectra from parallel optical layers (about 0.2 mm thick) of samples placed between the KBr crystals were recorded. In the reflection mode, an ATR attachment with a diamond window was used. The DC calculation method was applied based on the application of a monomer absorption band at 1638 cm-1 (stretching vibration double bond C=C of the vinyl group) without using a reference band. The data were analyzed by performing an ANOVA test comparison between sample groups at the significance level α = 0.05. For all tested materials, the polymerization kinetics consist of three stages. The fastest stage occurs during the irradiation, and the achieved DC value is 70-75% of the maximum value 5 s after the irradiation. Another 15-20% DC increase at a moderate speed takes about 15-20 min. There is also a very slow further increase in DC of 5-10% within 5 days after irradiation. For 8 out of the 11 tested fillings, the optimal photopolymerization conditions are as follows: a power density of 400 or 1000 mW/cm2; an exposure time of 10 s; and a thickness of the irradiated resin layer of up to 2 mm. The influence of various conditions and factors on the reaction kinetics is dominant only in the early, rapid phase of the conversion. After longer times, the DC values gradually level out under different light conditions. The DC of the dental resins are dependent on the irradiance, light source, filler type, time after irradiance, and monomer thickness.
Collapse
Affiliation(s)
- Mirosław Kwaśny
- Institute of Optoelectronics, Military University of Technology, S. Kaliskiego 2 Str., 00-908 Warsaw, Poland
| | - Jakub Polkowski
- Faculty of Mechanical Engineering, Military University of Technology, S. Kaliskiego 2 Str., 00-908 Warsaw, Poland
| | - Aneta Bombalska
- Institute of Optoelectronics, Military University of Technology, S. Kaliskiego 2 Str., 00-908 Warsaw, Poland
| |
Collapse
|
6
|
Barakah H. Effect of different curing times and distances on the microhardness of nanofilled resin-based composite restoration polymerized with high-intensity LED light curing units. Saudi Dent J 2021; 33:1035-1041. [PMID: 34938047 PMCID: PMC8665174 DOI: 10.1016/j.sdentj.2021.05.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 05/27/2021] [Accepted: 05/30/2021] [Indexed: 11/30/2022] Open
Abstract
Purpose This study examined the effect of different distances and curing times on the microhardness (VHN) of nanofilled resin-based composite (RBC) restorations polymerized with high-intensity LED LCUs. Materials and methods Seventy-five RBC specimens (2 mm thickness and 5 mm diameter) were fabricated from Tetric-N-Ceram (Ivoclar Vivadent). Each of the 25 specimens was polymerized by means of one of three types of high-intensity LED LCUs: (B) Blue-Phase-G2 (polywave LED, Ivoclar Vivadent), (E) Elipar S10 TM (single-peak, 3 M ESPE), and (P) Planmica Lumion (single-peak, Mectron) at three different distances (0 mm, 2 mm, and 4 mm) at 20 sec, 40 s, and 60 sec. A microhardness tester (NOVA, Innovatest, The Netherlands) was used to measure the VHN from the top and bottom surfaces. Data for VHN were analyzed using mixed ANOVA, followed by post hoc analyses with p-values < 0.05. Results A significant difference was found in VHN between all three LED LCUs, where (B) specimens had the highest means, followed by (E) and (P). Bottom surface VHN values were reduced significantly (p < 0.05) compared to top surface values in all LCU types. With increasing distances up to 2 mm and 4 mm, VHN values with (E) and (P) were significantly reduced on the top and bottom surfaces (p < 0.05). When the curing times were increased for 40 and 60 sec, the VHN values were significantly improved (p < 0.05). Meanwhile, increasing the distance with (B) did not significantly reduce the VHN. Moreover, increasing the curing times did not significantly improve the VHN of the bottom surfaces. Conclusion High-intensity LCUs have variable effects on the surface (top/bottom) hardness of Tetric-N-Ceram nanofilled RBC restoration. With increasing distance, VHN was reduced; therefore, compensation with more curing time (2 mm/40 sec and 4 mm/60 sec) is highly recommended with Elipar S10 and Planmica Lumion LCUs to improve the material surface hardness.
Collapse
Affiliation(s)
- Haifa Barakah
- Department of Restorative Dentistry, Lecturer at Collage of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
7
|
Baldo VDO, Pedrosa MDS, Medeiros IS. Post-cure heat treatments influence on mechanical and optical properties of resin composites. Braz Dent J 2021; 32:96-105. [PMID: 34787256 DOI: 10.1590/0103-6440202104333] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 06/15/2021] [Indexed: 11/22/2022] Open
Abstract
This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.
Collapse
Affiliation(s)
- Vitor de Oliveira Baldo
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo ,São Paulo,Brazil
| | - Marlus da Silva Pedrosa
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo ,São Paulo,Brazil
| | - Igor Studart Medeiros
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo ,São Paulo,Brazil
| |
Collapse
|
8
|
Balagopal S, Geethapriya N, Anisha S, Hemasathya BA, Vandana J, Dhatshayani C. Comparative evaluation of the degree of conversion of four different composites polymerized using ultrafast photopolymerization technique: An in vitro study. J Conserv Dent 2021; 24:77-82. [PMID: 34475685 PMCID: PMC8378501 DOI: 10.4103/jcd.jcd_648_20] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2020] [Revised: 01/24/2021] [Accepted: 02/09/2021] [Indexed: 11/04/2022] Open
Abstract
Context Lower degree of conversion (DC%) of monomer to polymer in a resin composite restoration could be a health hazard for the patient as well as it could affect the longevity of the restoration. Aims This study is aimed to compare and evaluate the DC% of four different composites polymerized using ultrafast photopolymerization. Settings and Design In-vitro study. Materials and Methods A total of 40 disc-shaped composite samples were used in the study. Twenty samples were prepared for each group using 2 mm height and 6 mm diameter Tygon tube as a matrix. All of the composites were cured using the Woodpecker i Led light-curing unit with an intensity of 2300-2500 mW/cm2 (TURBO mode). Samples in Group 1 were cured for 1 s and samples in Group 2 were cured for 3 s. Each group had 4 subgroups of five samples of the 4 resin composites tested. After photo-activation, the specimens were stored under dark dry conditions at room temperature for 24 h before testing. The DC% was measured using Fourier-transform infrared spectroscopy. Statistical Analysis Used The DC% were analyzed using ANOVA, and Tukey HSD post hoc test using IBM SPSS 21 software. Results Among the experimental groups, Group 2 showed a higher DC% which ranges from 93.7% to 95.4% than Group 1 which ranges from 58.5% to 65.5%. There was a statistically significant difference in the DC% among the materials tested (P < 0.05). Conclusions Within the limitations of the study, it was concluded that composites cured for 3 s showed a higher DC% which ranges from 93.7% to 95.4% than those cured for 1 s. The DC% also varied among the four different composites tested.
Collapse
Affiliation(s)
- Sundaresan Balagopal
- Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India
| | - Nagarajan Geethapriya
- Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India
| | - Sebatni Anisha
- Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India
| | - Bahavathi Ananthan Hemasathya
- Department of Conservative Dentistry and Endodontics, Adhiparasakthi Dental College and Hospital, Melmaruvathur, Tamil Nadu, India
| | - James Vandana
- Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India
| | - Chandrasekaran Dhatshayani
- Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India
| |
Collapse
|
9
|
Monomer Conversion, Dimensional Stability, Biaxial Flexural Strength, Ion Release, and Cytotoxicity of Resin-Modified Glass Ionomer Cements Containing Methacrylate-Functionalized Polyacids and Spherical Pre-Reacted Glass Fillers. Polymers (Basel) 2021; 13:polym13162742. [PMID: 34451281 PMCID: PMC8399068 DOI: 10.3390/polym13162742] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 08/11/2021] [Accepted: 08/12/2021] [Indexed: 11/17/2022] Open
Abstract
The aim of this study was to prepare RMGICs for pulp protection that contain polyacids functionalized with methacrylate groups (CMs) to enable light-activated polymerization without the need for toxic 2-hydroxyethyl methacrylate (HEMA) monomers. The effects of using CM liquids with 0 or 5 wt% HEMA on the physical/mechanical properties and cytotoxicity of the experimental RMGICs were assessed. Spherical pre-reacted glass fillers (SPG) were used as the powder phase. The experimental RMGICs were prepared by mixing SPG with CM liquid (0 wt% HEMA, F1) or CMH liquid (5 wt% HEMA, F2). Commercial materials (Vitrebond, VB; TheraCal LC, TC) were used for the comparisons. The degree of monomer conversion and fluoride release of both F1 and F2 were significantly lower than those of VB. F1 showed comparable biaxial flexural strength with VB but higher strength than TC. The dimensional stability (mass/volume changes) of the experimental materials was comparable with that of the commercial materials. F1 and F2 exhibited higher Sr/Ca ion release and relative cell viability than VB. The use of CMH liquid reduced the strength but enhanced the fluoride release of the experimental RMGICs. In conclusion, the experimental RMGICs showed comparable strength but lower cytotoxicity compared to the commercial RMGICs. These novel materials could be used as alternative materials for pulp protection.
Collapse
|
10
|
Fanfoni L, De Biasi M, Antollovich G, Di Lenarda R, Angerame D. Evaluation of degree of conversion, rate of cure, microhardness, depth of cure, and contraction stress of new nanohybrid composites containing pre-polymerized spherical filler. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:127. [PMID: 33247779 DOI: 10.1007/s10856-020-06464-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 11/03/2020] [Indexed: 06/12/2023]
Abstract
The aim of the present study was to characterize nanohybrid and nanofilled composites in terms of degree of conversion (DC), rate of cure (RC), microhardness (Vickers hardness number; VHN), depth of cure, and contraction stress (CS). Ceram.X® universal- A3, duo enamel E2, and duo dentin D3 composites were compared to Tetric EvoCeram® and FiltekTMSupreme XTE composites of equivalent dentin and enamel shades under a 40 s photopolymerization protocol. DC was measured by infrared spectroscopy, calculating RC from the kinetic curve. Top and bottom VHN were determined using a Vickers indenter, and bottom/top surface ratio (Vickers hardness ratio; VHR) calculated. CS vs. time was assessed by a universal testing machine and normalized for the specimen bonding area. All materials showed DC < 60%, Ceram.X® composites reaching higher values than the other composites of corresponding shades. RC at 5 s of photopolymerization was always higher than that at 10 s. All the Ceram.X® composites and the lighter-shaded Tetric EvoCeram® and FiltekTMSupreme XTE composites reached the RC plateau after 25 s, the remaining materials showed a slower kinetic trend. Tetric EvoCeram® and FiltekTMSupreme XTE composites displayed the softest and the hardest surfaces, respectively. Differently from darker-shaded materials, the universal and the three enamel-shaded composites resulted optimally cured (VHR > 80%). The tested composites differed in CS both during and after light cure, Tetric EvoCeram® and FiltekTMSupreme XTE composites displaying the highest and the lowest CS, respectively. Only the Ceram.X® universal-A3 reached a CS plateau value. The tested composites exhibited material-dependent chemo-mechanical properties. Increasing the curing time and/or reducing the composite layer thickness for dentin-shaded composites appears advisable.
Collapse
Affiliation(s)
- Lidia Fanfoni
- University Clinical Department of Medical, Surgical, and Health Sciences, University of Trieste, Trieste, Italy
| | - Matteo De Biasi
- University Clinical Department of Medical, Surgical, and Health Sciences, University of Trieste, Trieste, Italy
| | - Gabriele Antollovich
- University Clinical Department of Medical, Surgical, and Health Sciences, University of Trieste, Trieste, Italy
| | - Roberto Di Lenarda
- University Clinical Department of Medical, Surgical, and Health Sciences, University of Trieste, Trieste, Italy
| | - Daniele Angerame
- University Clinical Department of Medical, Surgical, and Health Sciences, University of Trieste, Trieste, Italy.
| |
Collapse
|
11
|
Polymerization shrinkage kinetics and degree of conversion of commercial and experimental resin modified glass ionomer luting cements (RMGICs). Dent Mater 2020; 36:893-904. [DOI: 10.1016/j.dental.2020.04.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 04/26/2020] [Indexed: 11/24/2022]
|
12
|
Lin GSS, Abdul Ghani NRN, Ismail NH, Singbal KP, Yusuff NMM. Polymerization Shrinkage and Degree of Conversion of New Zirconia-Reinforced Rice Husk Nanohybrid Composite. Eur J Dent 2020; 14:448-455. [PMID: 32599624 PMCID: PMC7440950 DOI: 10.1055/s-0040-1713951] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objectives
This study aimed to compare the polymerization shrinkage and degree of conversion of new zirconia-reinforced rice husk nanohybrid composite with commercialized microhybrid and nanofilled composites.
Materials and Methods
Overall, 180 samples were used for polymerization shrinkage (buoyancy and optical methods) and degree of conversion tests in which they were divided into Group 1, nanofilled composite (Filtek-Z350- XT; 3M ESPE, St Paul, MN 55144-1000, USA), Group 2, microhybrid composite (Zmack-Comp), and Group 3, nanohybrid composite (Zr-Hybrid). Polymerization shrinkage test was performed using buoyancy and optical methods. For buoyancy method, samples were weighed in air and water to calculate the shrinkage value, whereas, for optical method, images of nonpolymerized samples were captured under a digital microscope and recaptured again after light-cured to calculate the percentage of shrinkage. Degree of conversion was tested using Fourier-transform infrared spectroscopy spectrometer.
Statistical Analysis
Data were analyzed using one-way analysis of variance complemented by post hoc Dunnett’s T3 test for polymerization shrinkage and Tukey’s honestly significant difference test for degree of conversion. Level of significance was set at
p
< 0.05.
Results
Group 3 demonstrated similar polymerization shrinkage with Group 1, but lower shrinkage (
p
< 0.05) than Group 2 based on buoyancy method. However, optical method (
p
< 0.05) showed that Group 3 had the lowest shrinkage, followed by Group 1 and lastly Group 2. Besides, Group 3 showed a significantly higher degree of conversion (
p
< 0.05) than Group 1 and comparable conversion value with Group 2.
Conclusions
Zirconia-reinforced rice husk nanohybrid composite showed excellent shrinkage and conversion values, hence can be considered as an alternative to commercially available composite resins.
Collapse
Affiliation(s)
- Galvin Sim Siang Lin
- Conservative Dentistry Unit, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu, Kelantan, Malaysia
| | - Nik Rozainah Nik Abdul Ghani
- Conservative Dentistry Unit, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu, Kelantan, Malaysia
| | - Noor Huda Ismail
- Prosthodontic Unit, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu, Kelantan, Malaysia
| | - Kiran Prabhakar Singbal
- Department of Restorative Dentistry, Faculty of Dentistry, Mahsa University, Selangor, Malaysia
| | - Noraida Mamat Mohd Yusuff
- Paediatric Dentistry Unit, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kota Bharu, Kelantan, Malaysia
| |
Collapse
|
13
|
Xu T, Li X, Wang H, Zheng G, Yu G, Wang H, Zhu S. Polymerization shrinkage kinetics and degree of conversion of resin composites. J Oral Sci 2020; 62:275-280. [PMID: 32493864 DOI: 10.2334/josnusd.19-0157] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
This study compared shrinkage strain, polymerization shrinkage kinetics, and degree of conversion (DC) of a set of resin composites and investigated their influencing factors. Ten commercial resin composites were assessed, and 5 specimens (n = 5) were developed for material and subjected to light curing using light emitting diode light at 650 mW/cm2 for 40 s. The laser triangulation method was adopted to assess the shrinkage strain, and Fourier transform infrared spectroscopy was used to measure DC. The shrinkage strain was monitored for 5 min in real time and its data were subjected to differential calculations to get the shrinkage strain rate curve with respect to time, obtaining the maximum shrinkage strain rate (Rmax) and gel time. The values of shrinkage strain varied from 1.28% to 2.10%. The Rmax values were between 5.17 μm/s and 21.83 μm/s. Gel time values varied from 3.08 s to 4.32 s. The DC yielded values ranging from 53.62% to 87.01%. The values of polymerization shrinkage and DC were dependent on the composition of materials, including the monomer matrix and filler system. Compared to the micro-filler materials, the nano-filler resin composites had higher values of DC. Some resin composites are suitable for clinical applications because of their superior polymerization shrinkage properties and DC.
Collapse
Affiliation(s)
- Tong Xu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Xuan Li
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Han Wang
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Gang Zheng
- Department of Dental Materials, School and Hospital of Stomatology, Peking University
| | - Gaigai Yu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Huimin Wang
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| | - Song Zhu
- Department of Prosthodontics, School and Hospital of Stomatology, Jilin University
| |
Collapse
|
14
|
Influence of different light-curing units in surface roughness and gloss of resin composites for bleached teeth after challenges. J Mech Behav Biomed Mater 2020; 102:103458. [DOI: 10.1016/j.jmbbm.2019.103458] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Revised: 09/27/2019] [Accepted: 09/28/2019] [Indexed: 11/18/2022]
|
15
|
How Can Different Polishing Timing Influence Methacrylate and Dimethacrylate Bulk Fill Composites? Evaluation of Chemical and Physical Properties. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1965818. [PMID: 32382532 PMCID: PMC7199574 DOI: 10.1155/2020/1965818] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 12/07/2019] [Indexed: 11/17/2022]
Abstract
The polishing procedure is commonly performed after direct composite restorations, and little information exists regarding the right timing during which it should be performed on bulk fill composites. This study investigated the effect of polishing timing on the degree of conversion (DC), Vickers microhardness (VMH), and surface morphology of a methacrylate- (MET-) and dimethacrylate- (DMET-) based bulk fill composite, by using FT-NIR, microhardness tester, and SEM. Composite samples were divided as follows: in Group I (immediate), samples were polished immediately after curing (t0); in Group D (delayed), samples were polished after 24 h from curing (t24), whereas the unpolished samples were considered as controls (Group C). The DC and VMH values were evaluated before and after polishing, at t0 and t24. Statistical analysis was performed with a significance level set at p < 0.05. At t0, DC increased after polishing in both tested composites (p < 0.05), while at t24, Group I and Group D were not different. By considering VMH, in the case of MET, all groups were not different both at t0 and t24. On the other hand, at t0, VMH values of DMET increased after polishing. At t24, DMET Group I and DMET Group D were not different. Qualitative evaluations of scanning electron micrographs showed that the surface morphology of MET presented a more irregular aspect than the DMET one. In summary, since the immediate polishing of MET can improve the DC, without negatively affecting VMH, but showing an irregular surface, it is suggested to wait 24 hours before proceeding with polishing. Otherwise, for DMET, the immediate polishing could definitively be recommended, since it improves both DC and VMH, also producing a regular surface. Therefore, clinicians may always safely polish a restoration performed using DMET-based bulk fill composites in one-chair appointment, avoiding a second appointment.
Collapse
|
16
|
Cardoso IO, Machado AC, Teixeira DNR, Basílio FC, Marletta A, Soares PV. Influence of Different Cordless Light-emitting-diode Units and Battery Levels on Chemical, Mechanical, and Physical Properties of Composite Resin. Oper Dent 2019; 45:377-386. [DOI: 10.2341/19-095-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/15/2019] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
Irradiance may decrease as the light-emitting diode (LED) is discharged. Therefore, the LED must be charged carefully to prevent the possibility of influencing the chemical, mechanical, and physical properties of composite resin.
SUMMARY
The aim of this study was to evaluate the influence of different light-emitting diode (LED) curing units and battery levels on the chemical, mechanical, and physical properties of composite resins. The irradiance for each cycle from full to completely discharged battery level was evaluated, for five different new cordless LED units: Optilight Color (Gnatus), Bluephase (Ivoclar), Valo (Ultradent), Radii Plus (SDI), and Radii Xpert (SDI). After the irradiance evaluation, composite resin specimens were prepared and light cured, while varying the battery level for each LED unit: high level (HL, 100%), medium level (ML, 50%), and low level (LL, 10%). The degree of conversion, diametral tensile strength, sorption, and solubility were also evaluated. Data were checked for homoscedasticity and submitted to two-way and three-way analysis of variance, depending on the test performed, followed by the Tukey test with a significance level of 95%. A negative correlation was found between irradiance and cycles of light curing, which was checked by the Pearson correlation test. Valo and Radii Xpert were not influenced by the battery level in any test performed. However, different battery levels for some LED units can influence the degree of conversion, diametral tensile strength, sorption, and solubility of composite resins.
Collapse
|
17
|
Preparation of silica–poly(methyl methacrylate) composite with a nanoscale dual-network structure and hardness comparable to human enamel. Dent Mater 2019; 35:893-899. [DOI: 10.1016/j.dental.2019.03.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 02/17/2019] [Accepted: 03/15/2019] [Indexed: 11/21/2022]
|
18
|
Reinhardt JW, Balbierz MM, Schultz CM, Simetich B, Beatty MW. Effect of Tooth-Whitening Procedures on Stained Composite Resins. Oper Dent 2019; 44:65-75. [DOI: 10.2341/17-301-l] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
In this laboratory study, a composite resin was stained to a visibly discernible level using both coffee and red wine over 14 days (change was considered clinically noticeable and significant when ΔEab*≥2.7). Color change was measured at one, three, seven, and 14 days of staining. Although the nature of color change was different for the two staining solutions, the overall degree of staining (ΔEab*) rendered by either coffee or wine at each time interval was not significantly different (p≥0.05). Four whitening protocols were applied to stained composites. Treatment included applications of distilled water (control), Crest Pro-Health [HD] toothpaste, Crest Whitestrips, Opalescence PF bleach (15%), and application of a fine pumice polishing (Preppies). HD toothpaste and Whitestrips were applied daily for 21 days, Opalescence was applied daily for 10 days, and polishing was applied once. Each of the whitening products, applied in a manner simulating at-home or in-office treatment, was effective in producing color improvements (lightening) over controls (p<0.05), but none of the four treatments produced lightening that was significantly different from the other treatments (p≥0.05). A comparison of final composite color with that measured at baseline showed that Opalescence returned composite color to an acceptable level following exposure to both staining solutions (ΔEab*<2.7), Whitestrips returned color close to baseline for wine-stained composites, and HD paste and polishing permitted residual stain to remain (ΔEab*≥2.7).
Collapse
Affiliation(s)
- JW Reinhardt
- John W Reinhardt, DDS, MS, MPH, Department of Adult Restorative Dentistry, UNMC College of Dentistry, Lincoln, NE, USA
| | - MM Balbierz
- Madison M Balbierz, DDS, Riverside Dental, Wichita, KS, USA
| | - CM Schultz
- Caitlin M. Schultz, DDS, Premier Dental, Omaha, NE, USA
| | - B Simetich
- Bobby Simetich, BS, Research Coordinator, Department of Adult Restorative Dentistry, UNMC College of Dentistry, Lincoln, NE, USA
| | - MW Beatty
- Mark W Beatty, DDS, MS, MSD, MSE, Research Service, Veterans Affairs Nebraska–Western Iowa Healthcare System, Omaha, NE, and Professor and Director, Section of Biomaterials, Department of Adult Restorative Dentistry, UNMC College of Dentistry, Lincoln, NE, USA
| |
Collapse
|
19
|
Amato P, Martins LP, Gatti A, Pretel H, Martins RP. Influence of different wavelengths peaks in LED units on the degree of conversion of orthodontic composites. J World Fed Orthod 2016. [DOI: 10.1016/j.ejwf.2016.10.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
Gonulol N, Ozer S, Tunc ES. Effect of a third-generation LED LCU on microhardness of tooth-colored restorative materials. Int J Paediatr Dent 2016; 26:376-82. [PMID: 26548449 DOI: 10.1111/ipd.12213] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To assess the effects of different modes of a third-generation light-curing unit (LCU) (VALO) on the microhardness of restorative materials. DESIGN A microhybrid composite resin (Filtek(™) Z550), a giomer (Beautifil II), a compomer (Dyract eXtra) and a RMGIC (Photac(™) Fil) were used in the study. Three different modes of VALO were tested and a second-generation LCU (Elipar S10) was used as a control. The microhardness (VHN) was measured using a Vickers Hardness tester. Data were analyzed using two-way anova and post hoc Tukey's test (P < 0.05). RESULTS The Filtek Z550 group had the highest VHN values followed by Photac Fil, Beautifil II and the Dyract eXtra at both top and bottom surfaces, however the difference between Filtek Z550 and Photac Fil was not statistically significant for the bottom surfaces (P > 0.05). Of the different curing protocols tested, the VALO LCU in Mode 3 resulted in the lowest VHN values at both top and bottom surfaces (P < 0.05). CONCLUSION Based on the results of this study, it can be concluded that the high-power mode of the VALO LCU can be recommended for clinical applications especially in pediatric patients, as it can shorten the time required to adequately polymerize resin-based tooth-colored restorative materials.
Collapse
Affiliation(s)
- Nihan Gonulol
- Department of Restorative Dentistry, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| | - Sezin Ozer
- Department of Pediatric Dentistry, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| | - Emine Sen Tunc
- Department of Pediatric Dentistry, Faculty of Dentistry, Ondokuz Mayıs University, Samsun, Turkey
| |
Collapse
|
21
|
Mainjot A, Dupont N, Oudkerk J, Dewael T, Sadoun M. From Artisanal to CAD-CAM Blocks. J Dent Res 2016; 95:487-95. [DOI: 10.1177/0022034516634286] [Citation(s) in RCA: 170] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Indirect composites have been undergoing an impressive evolution over the last few years. Specifically, recent developments in computer-aided design–computer-aided manufacturing (CAD-CAM) blocks have been associated with new polymerization modes, innovative microstructures, and different compositions. All these recent breakthroughs have introduced important gaps among the properties of the different materials. This critical state-of-the-art review analyzes the strengths and weaknesses of the different varieties of CAD-CAM composite materials, especially as compared with direct and artisanal indirect composites. Indeed, new polymerization modes used for CAD-CAM blocks—especially high temperature (HT) and, most of all, high temperature–high pressure (HT-HP)—are shown to significantly increase the degree of conversion in comparison with light-cured composites. Industrial processes also allow for the augmentation of the filler content and for the realization of more homogeneous structures with fewer flaws. In addition, due to their increased degree of conversion and their different monomer composition, some CAD-CAM blocks are more advantageous in terms of toxicity and monomer release. Finally, materials with a polymer-infiltrated ceramic network (PICN) microstructure exhibit higher flexural strength and a more favorable elasticity modulus than materials with a dispersed filler microstructure. Consequently, some high-performance composite CAD-CAM blocks—particularly experimental PICNs—can now rival glass-ceramics, such as lithium-disilicate glass-ceramics, for use as bonded partial restorations and crowns on natural teeth and implants. Being able to be manufactured in very low thicknesses, they offer the possibility of developing innovative minimally invasive treatment strategies, such as “no prep” treatment of worn dentition. Current issues are related to the study of bonding and wear properties of the different varieties of CAD-CAM composites. There is also a crucial need to conduct clinical studies. Last, manufacturers should provide more complete information regarding their product polymerization process, microstructure, and composition, which significantly influence CAD-CAM material properties.
Collapse
Affiliation(s)
- A.K. Mainjot
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - N.M. Dupont
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - J.C. Oudkerk
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | - T.Y. Dewael
- Dental Biomaterials Research Unit (d-BRU) and Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège (ULg) and University of Liège Hospital (CHU), Liège, Belgium
| | | |
Collapse
|
22
|
Şişman R, Aksoy A, Yalçın M, Karaöz E. Cytotoxic effects of bulk fill composite resins on human dental pulp stem cells. J Oral Sci 2016; 58:299-305. [DOI: 10.2334/josnusd.15-0603] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Reyhan Şişman
- Department of Restorative Dentistry, Faculty of Dentistry, University of Inonu
| | - Ayça Aksoy
- Faculty of Bioengineering, Institute of Science, Yildiz Technical University
| | - Muhammet Yalçın
- Department of Restorative Dentistry, Faculty of Dentistry, University of Inonu
| | - Erdal Karaöz
- Liv Hospital, Center for Regenerative Medicine and Stem Cell Research and Manufacturing
| |
Collapse
|
23
|
Jafarzadeh TS, Erfan M, Behroozibakhsh M, Fatemi M, Masaeli R, Rezaei Y, Bagheri H, Erfan Y. Evaluation of Polymerization Efficacy in Composite Resins via FT-IR Spectroscopy and Vickers Microhardness Test. J Dent Res Dent Clin Dent Prospects 2015; 9:226-32. [PMID: 26889359 PMCID: PMC4753031 DOI: 10.15171/joddd.2015.041] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 07/26/2015] [Indexed: 12/04/2022] Open
Abstract
Background and aims. Polymerization efficacy affects the properties and performance of composite resin restorations.The purpose of this study was to evaluate the effectiveness of polymerization of two micro-hybrid, two nano-hybrid and one nano-filled ormocer-based composite resins, cured by two different light-curing systems, using Fourier transformation infrared (FT-IR) spectroscopy and Vickers microhardness testing at two different depths (top surface, 2 mm). Materials and methods. For FT-IR spectrometry, five cylindrical specimens (5mm in diameter × 2 mm in length) were prepared from each composite resin using Teflon molds and polymerized for 20 seconds. Then, 70-μm wafers were sectioned at the top surface and at2mm from the top surface. The degree of conversion for each sample was calculated using FT-IR spectroscopy. For Vickers micro-hardness testing, three cylindrical specimens were prepared from each composite resin and polymerized for 20 seconds. The Vickers microhardness test (Shimadzu, Type M, Japan) was performed at the top and bottom (depth=2 mm) surfaces of each specimen. Three-way ANOVA with independent variables and Tukey tests were performed at 95% significance level. Results. No significant differences were detected in degree of conversion and microhardness between LED and QTH light-curing units except for the ormocer-based specimen, CeramX, which exhibited significantly higher DC by LED. All the composite resins showed a significantly higher degree of conversion at the surface. Microhardness was not significantly affected by depth, except for Herculite XRV Ultra and CeramX, which showed higher values at the surface. Conclusion. Composite resins containing nano-particles generally exhibited more variations in degree of conversion and microhardness.
Collapse
Affiliation(s)
- Tahereh-Sadat Jafarzadeh
- Associate Professor, Department of Dental Biomaterials, Tehran University of Medical Sciences, Iranian Tissue Bank and Research Center, Tehran University of Medical Sciences Tehran, Iran
| | - Mohammad Erfan
- Associate Professor, Department of Pharmaceutics, School of Pharmacy, Shahid Bahashti University of Medical Sciences, Tehran, Iran
| | - Marjan Behroozibakhsh
- Assistant Professor, Research Center for Science and Technology in Medicine and Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Mostafa Fatemi
- Assistant Professor, Research Center for Science and Technology in Medicine and Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Reza Masaeli
- Ph.D Candidate, Research Center for Science and Technology in Medicine and Department of Dental Biomaterials, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Yashar Rezaei
- Assistant Professor, Department of Dental Biomaterials, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hossein Bagheri
- Assistant Professor, Dental Materials Research Center, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Yasaman Erfan
- Dental Student, The International Branch of Shahid Behesti University of Medical Sciences and Health Services, Tehran, Iran
| |
Collapse
|
24
|
García-Contreras R, Scougall-Vilchis R, Acosta-Torres L, Arenas-Arrocena C, García-Garduño R, de la Fuente-Hernández J. Vickers microhardness comparison of 4 composite resins with different types of filler. JOURNAL OF ORAL RESEARCH 2015. [DOI: 10.17126/joralres.2015.061] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
25
|
Degree of conversion and surface hardness of bulk-fill composite versus incremental-fill composite. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.tdj.2015.01.003] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
26
|
Pini NIP, Nagata JY, Sundfeld-Neto D, Correr-Sobrinho L, Soares A, Aguiar FHB, Lima DANL. Reestablishing Biology, Function, and Esthetics for Fractured, Immature Incisors. Oper Dent 2015; 40:341-9. [PMID: 25575198 DOI: 10.2341/14-167-t] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A seven-year-old boy with enamel-dentin fractures on both maxillary central incisors presented to the Piracicaba Dental School-UNICAMP seven days after the trauma. At the clinical evaluation, there were no clinical signs of pulp exposure, neither tooth was mobile, and both affected teeth presented a positive response to sensitivity tests and a negative response for percussion and palpation. The radiographic examination showed an undeveloped root and opened apex for both teeth. Indirect pulp capping was performed on the left maxillary central incisor, followed by a direct restoration. After one month, the patient complained of pain in the left central incisor, which responded negatively to sensitivity testing. Pulp revascularization was performed only on this tooth and was followed for 18 months. During this period, the left maxillary central incisor did not recover sensitivity, although radiographic examination showed apical closure, a slight increase in root length, and the formation of a mineralized barrier between the root canal and sealing material. The technique achieved its goal of restoring biological aspects, function, and esthetics of traumatized teeth when using this multidisciplinary approach.
Collapse
|
27
|
Scotti N, Venturello A, Borga FAC, Pasqualini D, Paolino DS, Geobaldo F, Berutti E. Post-curing conversion kinetics as functions of the irradiation time and increment thickness. J Appl Oral Sci 2013; 21:190-5. [PMID: 23739861 PMCID: PMC3881873 DOI: 10.1590/1678-7757201302380] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2012] [Accepted: 02/06/2013] [Indexed: 11/22/2022] Open
Abstract
Objective: This study evaluated the variation of conversion degree (DC) in the 12 hours following initial photoactivation of a low-shrinkage composite resin (Venus Diamond). Material and Methods: The conversion degree was monitored for 12 hours using Attenuated Total Reflection (ATR) F-TIR Spectroscopy. The composite was placed in 1 or 2 mm rings and cured for 10 or 20 seconds with a LED lamp. ATR spectra were acquired from the bottom surface of each sample immediately after the initial photoactivation (P=0), 30 minutes (P=0.5) and 12 hours after photoactivation (P=12) in order to obtain the DC progression during the post-curing period. Interactions between thickness (T), irradiation time (I) and post-curing (P) on the DC were calculated through ANOVA testing. Results: All the first order interactions were statistically significant, with the exception of the T-P interaction. Furthermore, the shift from P=0 to P=0.5 had a statistically higher influence than the shift from P=0.5 to P=12. The post-curing period played a fundamental role in reaching higher DC values with the low-shrinkage composite resin tested in this study. Moreover, both the irradiation time and the composite thickness strongly influenced the DC. Conclusions: Increased irradiation time may be useful in obtaining a high conversion degree (DC) with a low-shrinkage nano-hybrid composite resin, particularly with 2 mm composite layers.
Collapse
Affiliation(s)
- Nicola Scotti
- Department of Surgical Sciences, Dental School Lingotto, University of Turin, Turin, Italy.
| | | | | | | | | | | | | |
Collapse
|