1
|
Hoseinifar R, Mofidi M, Malekhosseini N. The Effect of Occlusal Loading on Gingival Microleakage of Bulk Fill Composites Compared with a Conventional Composite. JOURNAL OF DENTISTRY (SHIRAZ, IRAN) 2020; 21:87-94. [PMID: 32582822 PMCID: PMC7280547 DOI: 10.30476/dentjods.2019.77861.0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Statement of the Problem: Bulk fill composites have been introduced over the recent years in order to accelerate the process of tooth restoration
by inserting composite in bulk up to 4mm thickness. Occlusal loading may influence the gingival microleakage of this composite. Purpose: This in vitro study aims to evaluate the effect of occlusal loading on the gingival microleakage of bulk fill composites compared with a conventional composite. Materials and Method: In this experimental study, box only class II cavities with gingival margins placed 1mm below the cemento-enamel junction were prepared
on the mesial and distal surfaces of 36 maxillary premolars (72 cavities). The samples were divided into three groups and restored as follows:
Group 1 (Tetric N-Ceram, incremental filling), Group 2 (X-tra fill, bulk filling), Group 3 (Tetric N-Ceram Bulk Fill, bulk filling).
All restorations were thermocycled for 2000 cycles (5-50̊C) and then half of the samples were subjected to 200,000 cycles of loading.
All the specimens were immersed in 0.5% basic fuchsin for 48 hours, then, sectioned, and evaluated for microleakage with a stereomicroscope.
Data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests. p< 0.05 was considered significant. Results: There were no significant differences among the gingival microleakage of three composites in both unloaded and loaded groups. In addition,
no statistically significant difference was found between the microleakage of unloaded and loaded groups in all materials. Conclusion: Occlusal loading did not affect the gingival microleakage of bulk fill composites, and the microleakage of class II cavities restored
with the bulk filling technique was similar to that of restored with the incremental technique.
Collapse
Affiliation(s)
- Razieh Hoseinifar
- Oral and Dental Diseases Research Center, Dept. of Operative Dentistry, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
| | - Maryam Mofidi
- Dept. of Operative Dentistry, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
| | - Nima Malekhosseini
- Dental Student, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
| |
Collapse
|
2
|
Aydınoğlu A, Yoruç ABH. Effects of silane-modified fillers on properties of dental composite resin. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017. [DOI: 10.1016/j.msec.2017.04.151] [Citation(s) in RCA: 54] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
3
|
Cavalli V, Silva BG, Berger SB, Abuna G, Marson FC, Tabchoury CPM, Giannini M. Effect of Adhesive Restoration and Bleaching Technique on the Concentration of Hydrogen Peroxide In the Pulp Chamber. Oper Dent 2017; 42:E44-E54. [DOI: 10.2341/16-079-l] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
This study aimed to quantify the concentration of hydrogen peroxide into the pulp chamber in the presence or absence of adhesive enamel restorations and to analyze the resin-dentin interface of bleached groups. Bovine incisors (120) were randomly divided into three groups according to enamel treatment (n=40 each): (1) enamel without restoration (control); (2) enamel cavities (3 mm diameter × 1.5 mm depth) restored with a silorane-based (SB) system; or (3) enamel cavities (3 mm diameter × 1.5 mm depth) restored with a dimethacrylate-based (DB) system. Restorations were thermocycled, and all groups were submitted to one application of 35% hydrogen peroxide (HP) agent for 45 minutes and subjected to four light activation methods (n=10 each): without light, light-emitting diode (LED), LED/diode laser, or halogen light. Acetate buffer solution was placed into the pulp chamber before bleaching, and this solution was collected to spectrophotometrically determine the concentration of HP that reached the pulp chamber after bleaching. Rhodamine B was added to the HP agent and applied on additional enamel samples of each group for 24 hours. Samples were sectioned mesiodistally, and the bleaching agent was traced using confocal microscopy. According to two-way analysis of variance and Tukey test (α=0.05), the HP concentration in the pulp chamber of the control group was significantly lower than that of the SB group (p<0.05), regardless of light activation. No differences were observed between DB and SB groups and between control and DB groups, except for the DB halogen light activated group, which exhibited higher HP intrapulpal concentration (p<0.05). Confocal microscopy exhibited HP diffusion through the interface of the SB and DB restored groups as well as enamel prisms in the control group. The SB restorative system increased the HP diffusion into the pulp chamber, but HP was able to diffuse even in the absence of enamel restorations.
Collapse
Affiliation(s)
- V Cavalli
- Vanessa Cavalli, DDS, MS, PhD, associate professor, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - BG Silva
- Bruna G Silva, DDS, MS student, Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - SB Berger
- Sandrine B Berger, DDS, MS, PhD, associate professor, Department of Restorative Dentistry, University of North Parana, Londrina, Brazil
| | - G Abuna
- Gabriel Abuna, DDS, MS, PhD student, Department of Dental Materials, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - FC Marson
- Fabiano Carlos Marson, DDS, MS, PhD, associate professor, Department of Operative Dentistry, Faculty Ingá, Maringá, Brazil
| | - CPM Tabchoury
- Cinthia P. M. Tabchoury, PharmD, MS, PhD, associate professor, Department of Physiological Sciences, Piracicaba Dental School University of Campinas, Piracicaba, Brazil
| | - M Giannini
- Marcelo Giannini, DDS, MS, PhD, associate professor, Department of Restorative Dentistry Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| |
Collapse
|
4
|
Kermanshah H, Yasini E, Hoseinifar R. Effect of cyclic loading on microleakage of silorane based composite compared with low shrinkage methacrylate-based composites. Dent Res J (Isfahan) 2016; 13:264-71. [PMID: 27274348 PMCID: PMC4878212 DOI: 10.4103/1735-3327.182188] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Background: There are many concerns regarding the marginal seal of composite restorations, especially when composite restorations are subjected to cyclic loading. The aim of this study was to evaluate the effect of cyclic loading on the microleakage of silorane based composite compared with low shrinkage methacrylate-based composites in class V cavities. Materials and Methods: In this in vitro study, class V cavities were prepared on the facial and lingual surfaces of 48 human premolars (96 cavities). The teeth were randomly divided into four groups of 12 teeth (24 cavities) each and restored as follows: Group 1 (Siloran System Adhesive + Filtek P90), Group 2 (All Bond SE + Aelite LS Posterior), Group 3 (Futurabond NR + Grandio), and Group 4 (G-Bond + Kalore-GC). All the specimens were thermocycled for 2000 cycles (5-55°C) and then half of the specimens from each group, were Load cycled. All teeth were immersed in 0.5% basic fuchsine dye, sectioned, and observed under a stereomicroscope. Data were analyzed using Wilcoxon test, Kruskal–Wallis, and Mann–Whitney U-tests. P < 0.05 was considered as significant. Results: In both unloaded and loaded groups, no statistically significant differences were observed among four composites at the occlusal margin, but a significant difference in gingival microleakage was found between Aelite and silorane. Occlusal and gingival microleakage was not affected by cyclic loading in none of the four restorative materials. Conclusion: Silorane did not provide better marginal seal than the low shrinkage methacrylate-based composites (except Aelite). In addition, cyclic loading did not affect the marginal microleakage of evaluated composite restorations.
Collapse
Affiliation(s)
- Hamid Kermanshah
- Department of Operative Dentistry, Dental Research Center, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Esmail Yasini
- Department of Operative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
| | - Razieh Hoseinifar
- Department of Operative Dentistry, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
| |
Collapse
|
5
|
Koohpeima F, Sharafeddin F, Jowkar Z, Ahmadzadeh S, Mokhtari MJ, Azarian B. Role of TiF4 in Microleakage of Silorane and Methacrylate-based Composite Resins in Class V Cavities. J Contemp Dent Pract 2016; 17:240-247. [PMID: 27207205 DOI: 10.5005/jp-journals-10024-1834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
AIM This study investigated the effect of TiF4 solution pretreat-ment on microleakage of silorane and nanofilled methacrylate-based composites in class V cavities. MATERIALS AND METHODS Forty-eight intact premolar teeth were randomly allocated to four groups of 12 teeth. Restorative techniques after standard class V tooth preparations were as follows: Group 1, Filtek P90 composite; group 2, Filtek Z350 XT; group 3, TiF4 solution pretreatment and Filtek P90 composite; group 4, TiF4 solution pretreatment and Filtek Z350 XT. After storing the specimens in distilled water at 37°C for 24 hours and followed by immersion of the specimens in a 0.5% basic-fuchsin solution for 24 hours, they were sectioned buccolingually to obtain four surfaces for each specimen for analysis of microleakage using a stereomicroscope. Data analysis was performed using Kruskal-Wallis test to compare the four groups and the Mann-Whitney test for paired comparisons with Statistical Package for the Social Sciences (SPSS) version 17 software. RESULTS At the enamel margins, microleakage score of the Filtek Z350 XT group was lower than those of the Filtek P90 with and without the application of the TiF4 (p = 0.009 and p = 0.031 respectively). At the dentin margins, groups 3 and 4 (TiF4+Filtek P90 and TiF4+Filtek z350 XT respectively) showed significantly lower microleakage than group 1 (Filtek P90). However, there was no significant difference between other groups (p > 0.05). CONCLUSION At the enamel margins, microleakage score of the silorane-based composite was more than that of the nanofilled composite. No significant differences were observed between the other groups. At the dentin margins, for the silorane-based composite restorations, TiF4 solution pretreatment resulted in significantly lower microleakage. However, the similar result was not observed for Filtek Z350 XT. Also, no significant difference was observed between microleakage scores of Filtek P90 and Filtek Z350 XT with or without TiF4 pretreatment. CLINICAL SIGNIFICANCE In spite of better mechanical and physical properties of modern composites than earlier methacrylate-based composites, polymerization shrinkage has been remaining as one of the main shortcomings of them. Different methods, such as using new low shrinkage resin composites and different dentin pretreatments, have been suggested to overcome this problem. This study evaluated the effect of TiF4 as pretreatment on microleakage of class V tooth preparations restored with a nanocomposite and a silorane-based resin composite.
Collapse
Affiliation(s)
- Fatemeh Koohpeima
- Department of Operative Dentistry, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Islamic Republic of Iran
| | - Farahnaz Sharafeddin
- Professor, Department of Operative Dentistry, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Islamic Republic of Iran, Phone: 36263193 e-mail:
| | - Zahra Jowkar
- Department of Operative Dentistry, School of Dentistry Shiraz University of Medical Sciences, Shiraz, Islamic Republic of Iran
| | - Samaneh Ahmadzadeh
- Department of Operative Dentistry, School of Dentistry Shiraz University of Medical Sciences, Shiraz, Islamic Republic of Iran
| | - Mohammad Javad Mokhtari
- Department of Biology, Elite Club, Zarghan Branch, Islamic Azad University, Zarghan, Islamic Republic of Iran
| | | |
Collapse
|
6
|
Kalmowicz J, Phebus JG, Owens BM, Johnson WW, King GT. Microleakage of Class I and II Composite Resin Restorations Using a Sonic-resin Placement System. Oper Dent 2015; 40:653-61. [PMID: 26237636 DOI: 10.2341/15-006-l] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To determine microleakage of posterior Class I and II restorations using the SonicFill composite resin system. METHODS AND MATERIALS Eighty previously extracted third molars were randomly assigned to four preparation/restoration groups (n=20): Group A: Class I preparations restored with SonicFill system/bulk fill; Group B: Class II preparations restored with SonicFill system/bulk fill; Group C: Class I preparations restored with Herculite Ultra composite resin/incremental technique; and Group D: Class II preparations restored with Herculite Ultra composite resin/incremental technique. Class I preparations were approximately 3.0 mm in width buccolingually and 3.0 mm in depth. Class II preparations were approximately 3.0 mm in width buccolingually, 1.5 mm in axial depth, and 4.0 mm in gingival depth. In all groups, the enamel and dentin surfaces were conditioned with Kerr 37.5% phosphoric acid, followed by application of Optibond Solo Plus adhesive system. Following restoration, the specimens were thermocycled, immersed in methylene blue dye, and embedded in acrylic resin. Specimen blocks were sectioned in the mesiodistal direction, with marginal dye penetration (microleakage) examined using a 20× binocular microscope. Class I and II restoration microleakage was scored separately using a 0-3 ordinal ranking system. Statistical analyses were conducted using nonparametric testing at the p < 0.05 level of significance. RESULTS Significantly less microleakage was associated with both Class I restorative groups (A and C), SonicFill bulk fill and Herculite Ultra incremental fill, compared to the Class II restorative groups (B and D), SonicFill/bulk fill and Herculite Ultra/incremental fill. CONCLUSIONS According to the results of this study, the materials (SonicFill vs Herculite Ultra), C-factors, and insertion techniques (bulk vs incremental) did not appear to be significant influences with regard to marginal microleakage; however, the type of preparation cavity (Class I vs Class II) and the subsequent bonding surface (enamel vs dentin [cementum]) proved to be significant factors.
Collapse
|
7
|
Effects of different light sources on microleakage of composite resins with different monomer structures. J Dent Sci 2014. [DOI: 10.1016/j.jds.2013.01.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
8
|
Isaac SZ, Bergamin ACP, Turssi CP, Amaral FLBD, Basting RT, França FMG. Evaluation of bond strength of silorane and methacrylate based restorative systems to dentin using different cavity models. J Appl Oral Sci 2014; 21:452-9. [PMID: 24212992 PMCID: PMC3881842 DOI: 10.1590/1679-775720130120] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2013] [Accepted: 08/12/2013] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS) to dentin of two different restorative systems: silorane-based (P90), and methacrylate-based (P60), using two cavity models. MATERIAL AND METHODS Occlusal enamel of 40 human third molars was removed to expose flat dentin surface. Class I cavities with 4 mm mesial-distal width, 3 mm buccal-lingual width and 3 mm depth (C-factor=4.5) were prepared in 20 teeth, which were divided into two groups (n=10) restored with P60 and P90, bulk-filled after dentin treatment according to manufacturer's instructions. Flat buccal dentin surfaces were prepared in the 20 remaining teeth (C-factor=0.2) and restored with resin blocks measuring 4x3x3 mm using the two restorative systems (n=10). The teeth were sectioned into samples with area between 0.85 and 1.25 mm2 that were submitted to µTBS testing, using a universal testing machine (EMIC) at speed of 0.5 mm/min. Fractured specimens were analyzed under stereomicroscope and categorized according to fracture pattern. Data were analyzed using ANOVA and Tukey Kramer tests. RESULTS For flat surfaces, P60 obtained higher bond strength values compared with P90. However, for Class I cavities, P60 showed significant reduction in bond strength (p<0.05). No statistical difference between restorative systems was shown for Class I cavity model (p>0.05), or between Class I Cavity and Flat Surface group, considering P90 restorative system (p>0.05). Regarding fracture pattern, there was no statistical difference among groups (p=0.0713) and 56.3% of the fractures were adhesive. CONCLUSION It was concluded that methacrylate-based composite µTBS was influenced by cavity models, and the use of silorane-based composite led to similar bond strength values compared to the methacrylate-based composite in cavities with high C-factor.
Collapse
Affiliation(s)
- Stephano Zerlottini Isaac
- Department of Restorative Dentistry, São Leopoldo Mandic Institute and Research Center, CampinasSP, Brazil
| | | | | | | | | | | |
Collapse
|
9
|
Experimental and FE displacement and polymerization stress of bonded restorations as a function of the C-Factor, volume and substrate stiffness. J Dent 2014; 42:140-8. [DOI: 10.1016/j.jdent.2013.11.016] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 11/18/2013] [Accepted: 11/25/2013] [Indexed: 11/17/2022] Open
|
10
|
Kasraei S, Azarsina M. Addition of silver nanoparticles reduces the wettability of methacrylate and silorane-based composites. Braz Oral Res 2013. [PMID: 23184163 DOI: 10.1590/s1806-83242012000600004] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Incorporation of silver nanoparticles into composite resins is recommended for their reported antibacterial properties, but this incorporation can affect the wettability of such materials. Therefore, this study evaluated the effect of nano-silver addition to silorane-based and methacrylate-based composites on their contact angle. Nano-silver particles were added to Z250 (methacrylate-based) and P90 (silorane-based) composites at 0.5% and 1% by weight. The control group had no additions. SEM-EDX analysis was performed to confirm the homogeneity of the nano-silver distribution. Seventy-two composite discs were prepared and standardized to the identical surface roughness values, and then distributed randomly into 6 groups containing 12 samples each (N = 12). Two random samples from each group were observed by atomic force microscopy. Distilled water contact angle measurements were performed for the wettability measurement. Two-way ANOVA, followed by the Tukey-HSD test, with a significance level of 5%, were used for data analysis. It was observed that wettability was significantly different between the composites (p = 0.0001), and that the addition of nano-silver caused a significant reduction in the contact angle (p = 0.0001). Wettability varied depending on the concentration of the nano silver (p = 0.008). Silorane-based composites have a higher contact angle than methacrylate-based composites. Within the limitations of this study, it can be concluded that the addition of 0.5% nano-silver particles to the composites caused a decrease in the contact angle of water.
Collapse
Affiliation(s)
- Shahin Kasraei
- Department of Operative Dentistry, Dental Research Center, Dental School, Hamadan Univ of Medical Sciences, Hamadan, Iran
| | | |
Collapse
|
11
|
Carvalho AO, Oliveira MTD, Nikaido T, Tagami J, Giannini M. Effect of adhesive system and application strategy on reduction of dentin permeability. Braz Oral Res 2012; 26:397-403. [DOI: 10.1590/s1806-83242012005000020] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2011] [Accepted: 06/06/2012] [Indexed: 11/21/2022] Open
|
12
|
Effect of cavity configuration (C factor) on the marginal adaptation of low-shrinking composite: a comparative ex vivo study. Int J Dent 2011; 2011:159749. [PMID: 21949664 PMCID: PMC3178442 DOI: 10.1155/2011/159749] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Revised: 07/12/2011] [Accepted: 07/14/2011] [Indexed: 11/19/2022] Open
Abstract
Aim. To investigate the effect of C factor on marginal adaptation of low-shrinking composite (Silorane).The null hypothesis was that the marginal adaptation of “Silorane” is not affected by the cavity configuration. Materials and Methods. A Silorane based and a methacrylate based composites, with their corresponding self-etch adhesive systems “Filtek Silorane/Silorane Adhesive Bond System and Filtek Z250/Prompt L-Pop” respectively were used. Standardized cavities were prepared on the buccal surfaces of 100 maxillary premolars. Teeth were grouped into 5 groups (n = 20), for the 5 C factors. Restored teeth were subjected to thermocycling. Microleakage testing was done and linear dye penetration was assessed using a stereomicroscope. Statistical analysis was done using the Student's t-test. Results. For the methacrylate based systems' overall leakage score was significantly higher than the Silorane-based one (P = 0.034). For the methacrylate-based, leakage was found in all tested teeth groups except group 1 (C factor 1/5). For the Silorane, One-way ANOVA revealed a statistically significant increase in dye penetration in the 5th group (P = 0.010). Conclusions. The null hypothesis was rejected. The Silorane-based resin although it resulted in a statistically significant good marginal adaptation, it showed tendency toward a high leakage score with C-factor of 5.
Collapse
|