1
|
Zangpo D, Uehara K, Kondo K, Kato M, Yoshimiya M, Nakatome M, Iino M. Estimating age at death by Hausdorff distance analyses of the fourth lumbar vertebral bodies using 3D postmortem CT images. Forensic Sci Med Pathol 2024; 20:472-479. [PMID: 37058209 DOI: 10.1007/s12024-023-00620-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/24/2023] [Indexed: 04/15/2023]
Abstract
The existing methods for determining adult age from human skeletons are mostly qualitative. However, a shift in quantifying age-related skeletal morphology on a quantitative scale is emerging. This study describes an intuitive variable extraction technique and quantifies skeletal morphology in continuous data to understand their aging pattern. A total of 200 postmortem CT images from the deceased aged 25-99 years (130 males, 70 females) who underwent forensic death investigations were used in the study. The 3D volume of the fourth lumbar vertebral body was segmented, smoothed, and post-processed using the open-source software ITK-SNAP and MeshLab, respectively. To measure the extent of 3D shape deformity due to aging, the Hausdorff distance (HD) analysis was performed. In our context, the maximum Hausdorff distance (maxHD) was chosen as a metric, which was subsequently studied for its correlation with age at death. A strong statistically significant positive correlation (P < 0.001) between maxHD and age at death was observed in both sexes (Spearman's rho = 0.742, male; Spearman's rho = 0.729, female). In simple linear regression analyses, the regression equations obtained yielded the standard error of estimates of 12.5 years and 13.1 years for males and females, respectively. Our study demonstrated that age-related vertebral morphology could be described using the HD method. Moreover, it encourages further studies with larger sample sizes and on other population backgrounds to validate the methodology.
Collapse
Affiliation(s)
- Dawa Zangpo
- Division of Forensic Medicine, Graduate School of Medicine, Tottori University, 86 Nishi-Cho, Yonago, 683-8503, Japan.
- Department of Forensic Medicine and Toxicology, Jigme Dorji Wangchuck National Referral Hospital, 11001, Thimphu, Bhutan.
| | - Kazutake Uehara
- Department of Mechanical Engineering, National Institute of Technology, Yonago College, Yonago, 683-8502, Japan
| | - Katsuya Kondo
- Department of Electrical and Electronic Engineering, Faculty of Engineering, Tottori University, Tottori, 680-8552, Japan
| | - Momone Kato
- Division of Forensic Medicine, Graduate School of Medicine, Tottori University, 86 Nishi-Cho, Yonago, 683-8503, Japan
| | - Motoo Yoshimiya
- Division of Forensic Medicine, Graduate School of Medicine, Tottori University, 86 Nishi-Cho, Yonago, 683-8503, Japan
| | - Masato Nakatome
- Division of Forensic Medicine, Graduate School of Medicine, Tottori University, 86 Nishi-Cho, Yonago, 683-8503, Japan
| | - Morio Iino
- Division of Forensic Medicine, Graduate School of Medicine, Tottori University, 86 Nishi-Cho, Yonago, 683-8503, Japan
| |
Collapse
|
2
|
Pera F, Pesce P, Bagnasco F, Pancini N, Carossa M, Baldelli L, Annunziata M, Migliorati M, Baldi D, Menini M. Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16020833. [PMID: 36676569 PMCID: PMC9861382 DOI: 10.3390/ma16020833] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 01/10/2023] [Accepted: 01/12/2023] [Indexed: 06/12/2023]
Abstract
BACKGROUND The aim of the present study was to investigate the accuracy of a new digital impression system, comparing it to the plaster impression technique in the realization of full-arch implant-supported metal frameworks. METHODS We took 11 scans (8 of the upper maxilla and 3 of the lower jaw) on a sample of nine patients previously rehabilitated with fixed full-arch screw-retained prostheses following the Columbus Bridge Protocol (CBP) with four to six implants (total: 51) since at least 4 months. Two impressions were taken for each dental arch: one analogic plaster impression using pick-up copings and an open tray technique and a second one using an intra-oral scanner. Two milled metal substructures were realised. The precision and passivity of the substructures were clinically analysed through the Sheffield test and endo-oral radiographs. Laboratory scans of the plaster casts obtained from an intra-oral scanner (IOS) and of the plaster casts obtained from traditional impression were compared with the intraoral scans following Hausdorff's method and an industrial digital method of optical detection to measure discrepancies. A Mann-Whitney test was performed in order to investigate average distances between surfaces after the superposition. RESULTS The Sheffield test demonstrated an excellent passivity of the frameworks obtained through both the digital and the analogic method. In 81.81% of cases (n = 9) both substructures were found to have a perfect fit with excellent passivity, while in 18.18% (n = 2) of cases the substructures were found to have a very slight discrepancy. From the radiographic examination, no gaps between the frameworks and the implant heads or multiunit abutments were observed, with 100% accuracy. By superimposing digital files of scans according to Hausdorff's method, a statistically significant discrepancy (p = 0.006) was found between the digital scans and the digital models obtained from plaster impressions. Three-dimensional optical detection found a mean discrepancy of 0.11 mm between the analogic cast and the cast derived from the digital impression. CONCLUSIONS The present study clinically demonstrates that milled implant-supported full-arch frameworks obtained through a digital scan and the herein described technique have an accuracy comparable to those obtained with traditional plaster impression.
Collapse
Affiliation(s)
- Francesco Pera
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, 10126 Turin, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Francesco Bagnasco
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Nicolò Pancini
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Massimo Carossa
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, 10126 Turin, Italy
| | - Lorenzo Baldelli
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Marco Annunziata
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania “Luigi Vanvitelli”, 81100 Caserta, Italy
| | - Marco Migliorati
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Domenico Baldi
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| |
Collapse
|
3
|
A digital workflow for pair matching of maxillary anterior teeth using a 3D segmentation technique for esthetic implant restorations. Sci Rep 2022; 12:14356. [PMID: 35999338 PMCID: PMC9399247 DOI: 10.1038/s41598-022-18652-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 08/17/2022] [Indexed: 11/09/2022] Open
Abstract
We investigated a state-of-the-art algorithm for 3D reconstruction with a pair-matching technique, which enabled the fabrication of individualized implant restorations in the esthetic zone. This method compared 3D mirror images of crowns and emergence profiles between symmetric tooth pairs in the anterior maxilla using digital slicewise DICOM segmentation and the superimposition of STL data. With the outline extraction of each segment provided by 100 patients, the Hausdorff distance (HD) between two point sets was calculated to identify the similarity of the sets. By using HD thresholds as a pair matching criterion, the true positive rates of crowns were 100, 98, and 98%, while the false negative rates were 0, 2, and 2% for central incisors, lateral incisors, and canines, respectively, indicating high pair matching accuracy (> 99%) and sensitivity (> 98%). The true positive rates of emergence profiles were 99, 100, and 98%, while the false negative rates were 1, 0, and 2% for central incisors, lateral incisors, and canines, respectively, indicating high pair matching accuracy (> 99%) and sensitivity (> 98%). Therefore, digitally flipped contours of crown and emergence profiles can be successfully transferred for implant reconstruction in the maxillary anterior region to optimize esthetics and function.
Collapse
|
4
|
Yoshida Y, Matsumura N, Yamada Y, Yamada M, Yokoyama Y, Matsumoto M, Nakamura M, Nagura T, Jinzaki M. Evaluation of three-dimensional acromiohumeral distance in the standing position and comparison with its conventional measuring methods. J Orthop Surg Res 2020; 15:436. [PMID: 32967710 PMCID: PMC7510276 DOI: 10.1186/s13018-020-01935-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 08/31/2020] [Indexed: 11/16/2022] Open
Abstract
Background Narrowing of the acromiohumeral distance (AHD) implies a rotator cuff tear. However, conventional AHD measurements using two-dimensional (2D) imaging or with the patient in the supine position might differ from that while standing during daily activity. This study aimed to evaluate the three-dimensional (3D) actual distance between the acromion and humeral head in the standing position and compare the AHD values with those obtained using conventional measuring methods. Methods Computed tomography (CT) images of 166 shoulders from 83 healthy volunteers (31 male and 52 female; mean age 40.1 ± 5.8 years; age range, 30–49 years) were prospectively acquired in the supine and standing positions using conventional and upright CT scanners, respectively. The minimum distance between the acromion and humeral head on the 3D surface models was considered as the 3D AHD. We measured the 2D AHD on anteroposterior digitally reconstructed radiographs. The AHD values were compared between the supine and standing positions and between the 2D and 3D measurements. Results The mean values of 2D AHD were 8.8 ± 1.3 mm (range, 5.9–15.4 mm) in the standing position and 8.1 ± 1.2 mm (range, 5.3–14.3 mm) in the supine position. The mean values of 3D AHD were 7.3 ± 1.4 mm (range, 4.7–14.0 mm) in the standing position and 6.6 ± 1.2 mm (range, 4.4–13.7 mm) in the supine position. The values of 3D AHD were significantly lower than those of 2D AHDs in both the standing and supine positions (P < 0.001). The values of 2D and 3D AHDs were significantly lower in the supine position than in the standing position (P < 0.001). Conclusions This study evaluated the 3D AHD of normal shoulders in the standing position using an upright CT scanner. The present results indicated that assessments in the supine position can underestimate the value of the AHD compared with those made in the standing position and that assessments using 2D analysis can overestimate the value.
Collapse
Affiliation(s)
- Yuki Yoshida
- Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Noboru Matsumura
- Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Yoshitake Yamada
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Minoru Yamada
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Yoichi Yokoyama
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Morio Matsumoto
- Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Masaya Nakamura
- Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Takeo Nagura
- Department of Orthopedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| |
Collapse
|
5
|
Isman O, Aktan AM, Ertas ET. Evaluating the effects of orthodontic materials, field of view, and artifact reduction mode on accuracy of CBCT-based caries detection. Clin Oral Investig 2019; 24:2487-2496. [PMID: 31811495 DOI: 10.1007/s00784-019-03112-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 10/07/2019] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To investigate the influence of orthodontic materials, field of view (FOV), and artifact reduction (AR) on the assessment of approximal caries using cone beam computed tomography. MATERIALS AND METHODS Forty non-cavitated and restoration-free human premolars and molars ranging from sound to various grades of lesions without cavitations were assigned to 13 groups with different combination of fix appliance equipment. CBCT (cone beam computed tomography) (Planmeca ProMax 3D Mid, Helsinki, Finland) images were obtained using combinations of three orthodontic bracket materials and two orthodontic archwire with small and large FOVs and with and without AR activation. Receiver operating characteristic (ROC) analysis was used to calculate the area under the ROC curve (AUC). RESULTS Interobserver agreement ranged from 0.44 to 0.92 and intraobserver agreement ranged from 0.50 to 0.99. Teeth lacking orthodontic materials had the highest Az values at 0.84. FOV and AR activation did not significantly affect AUC values (P > 0.05). The AUC data were significantly reduced by the addition of stainless steel wire, NT wire, or a combination of a stainless steel bracket with stainless steel wire (P < 0.05). CONCLUSIONS The addition of stainless steel wire, NT wire, or a stainless steel bracket with stainless steel wire combination prevented the diagnosis of non-cavitated interproximal tooth caries by CBCT. With and without AR modes and different FOVs did not influence the diagnosis of interproximal caries lesions with different types of orthodontic equipment. CLINICAL RELEVANCE A wide variety of brackets and wire combinations are used in the clinic; however, the extent to which these combinations impact the diagnosis of caries by CBCT as the effects of FOV and AR algorithms are unknown.
Collapse
Affiliation(s)
- Ozlem Isman
- Vocational High School of Health Service, Gaziantep University, 27310, Şehitkamil, Gaziantep, Turkey.
| | | | | |
Collapse
|
6
|
Arriola-Guillén LE, Rodríguez-Cárdenas YA, Ruíz-Mora GA, Aliaga-Del Castillo A, Schilling J, Dias-Da Silveira HL. Three-dimensional evaluation of the root resorption of maxillary incisors after the orthodontic traction of bicortically impacted canines: case reports. Prog Orthod 2019; 20:13. [PMID: 30931492 PMCID: PMC6441668 DOI: 10.1186/s40510-019-0267-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2018] [Accepted: 03/06/2019] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The root resorption of the maxillary incisors after the orthodontic traction of impacted canines is a concern for clinicians. The aim of this case series report was to evaluate the root resorption of the maxillary incisors after traction until the occlusal plane of the bicortically impacted canines (placed between the two cortical bones in the middle of the alveolar process) located in a complex position using three-dimensional superimposition. This case series report describes the root resorption of the maxillary incisors after orthodontic traction with NiTi closed coil springs and a heavy anchorage appliance in three cases of bilateral impacted canines located in a complex position (bicortically) near to midline. Cone-beam computed tomographies (CBCTs) were obtained before and after traction. Root resorption in all root surfaces of the maxillary incisors was evaluated with color-coded maps using the ITK-SNAP and the 3D Slicer software to indicate loss of the root surface (in red) or gain of the surface (in blue) and was quantified in millimeters by the superimposition method. RESULTS The root changes mainly occurred in the apical third of the maxillary incisor root and did not exceed 2 mm. CONCLUSIONS Root resorption of the maxillary incisors after the traction of bicortically impacted canines located in a complex position was observed mainly in the apex region, and the amount of root resorption was smaller than 2 mm in all root surfaces.
Collapse
Affiliation(s)
- Luis Ernesto Arriola-Guillén
- Division of Orthodontics, School of Dentistry, Universidad Científica del Sur, Calle Cantuarias 398, Miraflores, Lima Perú
- Division of Oral and Maxillofacial Radiology, School of Dentistry, Universidad Científica del Sur, Calle Cantuarias 398, MIraflores, Lima Perú
| | | | - Gustavo Armando Ruíz-Mora
- Division of Orthodontics, Faculty of Dentistry, Universidad Nacional de Colombia, Bogotá D.C., Colombia
| | - Aron Aliaga-Del Castillo
- Department of Orthodontics, Bauru Dental School, University of São Paulo, Bauru, São Paulo, Brazil
| | - Juan Schilling
- Division of Oral and Maxillofacial Radiology, School of Dentistry, Universidad Científica del Sur, Calle Cantuarias 398, MIraflores, Lima Perú
| | | |
Collapse
|