• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4598788)   Today's Articles (9738)   Subscriber (49356)
For: Mazzo CR, Reis ACD, Shimano AC, Valente MLDC. In vitro analysis of the influence of surface treatment of dental implants on primary stability. Braz Oral Res 2012;26:313-7. [DOI: 10.1590/s1806-83242012005000006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Accepted: 03/26/2012] [Indexed: 11/22/2022]  Open
Number Cited by Other Article(s)
1
BİlmenoĞlu ÇBİ, Özyurt A, Çİlİngİr AA, Turan FN. PRIMARY STABILITY IN VARIOUS-LEVELS IMPACTED IMPLANTS: AN EX-VIVO STUDY. J ORAL IMPLANTOL 2020;47:380-384. [PMID: 33270883 DOI: 10.1563/aaid-joi-d-19-00232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
2
TARDELLI JDC, VALENTE MLDC, DOS REIS AC. Influência da topografia de superfície nanométrica na estabilidade primária de mini-implantes dentários. REVISTA DE ODONTOLOGIA DA UNESP 2019. [DOI: 10.1590/1807-2577.01919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
3
Carmo Filho LCD, Marcello-Machado RM, Castilhos EDD, Del Bel Cury AA, Faot F. Can implant surfaces affect implant stability during osseointegration? A randomized clinical trial. Braz Oral Res 2018;32:e110. [PMID: 30379212 DOI: 10.1590/1807-3107bor-2018.vol32.0110] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 09/07/2018] [Indexed: 12/26/2022]  Open
4
Analysis of the influence of implant shape on primary stability using the correlation of multiple methods. Clin Oral Investig 2015;19:1861-6. [DOI: 10.1007/s00784-015-1417-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Accepted: 01/29/2015] [Indexed: 10/24/2022]
5
Valente MLDC, Lepri CP, dos Reis AC. In vitro microstructural analysis of dental implants subjected to insertion torque and pullout test. Braz Dent J 2014;25:343-5. [PMID: 25250500 DOI: 10.1590/0103-6440201302402] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Accepted: 05/11/2014] [Indexed: 11/22/2022]  Open
6
Oliscovicz NF, Valente MLDC, Marcantonio Junior E, Shimano AC, Reis ACD. Estudo in vitro da influência do formato e do tratamento de superfície de implantes odontológicos no torque de inserção, resistência ao arrancamento e frequência de ressonância. REVISTA DE ODONTOLOGIA DA UNESP 2013. [DOI: 10.1590/s1807-25772013000400008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]  Open
PrevPage 1 of 1 1Next