1
|
Liang M, Zhang X, Xu C, Cao J, Zhang Z. Anesthesia Assistance in Colonoscopy: Impact on Quality Indicators. Front Med (Lausanne) 2022; 9:872231. [PMID: 35911411 PMCID: PMC9326494 DOI: 10.3389/fmed.2022.872231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 06/07/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundAdenoma detection rate (ADR) and polyp detection rate (PDR) are both indicators for colonoscopy quality. Improving ADR or PDR is critical for reducing the incidence and mortality of colorectal cancer (CRC). Although several studies have focused on identifying the factors that may influence ADR or PDR, the evidence remains limited and inconclusive. We conducted a retrospective study to evaluate the effect of anesthesia assistance (AA) on ADR or PDR in patients undergoing colonoscopy screening and identify risk factors affecting ADR or PDR.MethodsWe reviewed electronic medical records of patients who underwent colonoscopy screening between May 2019 and August 2020. Patients were divided into two groups according to whether they received AA: patients in Group A underwent colonoscopy screening with AA, whereas patients in Group O underwent colonoscopy screening without AA. Propensity score matching (PSM) was utilized to account for differences in baseline characteristics. After, ADR and PDR were compared between the two groups. Binary logistic regression was employed to identify risk factors that affected ADR or PDR.ResultsOf 9432 patients who underwent colonoscopy examination during the study period, 7170 were included in the final analyses (Group A = 5756 and Group O = 1414). After PSM, 736 patients remained in each group for analyses. There was no significant difference between groups A and O (P > 0.05) in ADR or PDR. Binary logistic regression indicated that the endoscopic device version (Olympus HQ290), equipment image-based technique and number of images were independent risk factors that affected ADR, and the age (50–59 years and 60–69 years), gender (male), high-risk status, endoscopist seniority (senior endoscopist), equipment image-based technique and number of images were all independent risk factors that affected PDR.ConclusionsWe discovered that AA does not affect ADR or PDR. Despite improved patient satisfaction, using AA is unnecessary for improving colonoscopy quality. Endoscopists should consider all these factors as much as possible when performing colonoscopy screening.
Collapse
Affiliation(s)
- Min Liang
- Jiangsu Province Key Laboratory of Anesthesiology, Xuzhou Medical University, Xuzhou, China
- Jiangsu Province Key Laboratory of Anesthesia and Analgesia Application Technology, Xuzhou Medical University, Xuzhou, China
- Department of Anesthesiology, Liaocheng People's Hospital, Liaocheng, China
| | - Xinyan Zhang
- Department of Pathology, Liaocheng People's Hospital, Liaocheng, China
| | - Chunhong Xu
- Department of Gastroenterology, Liaocheng People's Hospital, Liaocheng, China
| | - Junli Cao
- Jiangsu Province Key Laboratory of Anesthesiology, Xuzhou Medical University, Xuzhou, China
- Jiangsu Province Key Laboratory of Anesthesia and Analgesia Application Technology, Xuzhou Medical University, Xuzhou, China
- NMPA Key Laboratory for Research and Evaluation of Narcotic and Psychotropic Drugs, Xuzhou Medical University, Xuzhou, China
- Department of Anesthesiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
| | - Zongwang Zhang
- Department of Anesthesiology, Liaocheng People's Hospital, Liaocheng, China
- *Correspondence: Zongwang Zhang
| |
Collapse
|
2
|
Lim S, Tritto G, Zeki S, DeMartino S. Regular feedback to individual endoscopists is associated with improved adenoma detection rate and other key performance indicators for colonoscopy. Frontline Gastroenterol 2022; 13:509-516. [PMID: 36250166 PMCID: PMC9555132 DOI: 10.1136/flgastro-2022-102091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 04/11/2022] [Indexed: 02/04/2023] Open
Abstract
OBJECTIVE Monitoring of key performance indicators (KPIs) is a vital element of endoscopy quality improvement. Adenoma detection rate (ADR) is considered the best marker for colonoscopic quality as it inversely correlates with subsequent colonic cancer incidence and mortality, while polyp detection rate (PDR) is an easier-to-calculate surrogate for ADR. This study assessed whether regular feedback to individual endoscopists about their KPIs improved departmental performance. METHODS Individual KPIs were calculated for a period of 8 years (January 2012-December 2019) and fed back to all endoscopists at 6 monthly intervals, alongside anonymised indicators for other endoscopists, aggregate departmental performance data and benchmarks. An automated natural language processing software (EndoMineR) was used to identify adenomas in pathology reports and calculate ADR. Linear regressions were calculated for departmental ADR, PDR and other KPIs at 6 monthly intervals. RESULTS 39 359 colonoscopies (average 2460 in every 6-month period, range 1799-3059) were performed by an average of 42 (range 34-50) endoscopists. A continuous improvement in collective performance including ADR (12.7%-21.0%, R2 0.92, p<0.001) and PDR (19.0%-29.6%, R2 0.77, p<0.001) was observed throughout the study. Other KPIs showed similar improvement. The detection of non-neoplastic polyps did not increase. When analysed separately, ADR and PDR appeared to improve for gastroenterologists and nurse endoscopists but not for surgeons. CONCLUSION Regular feedback with individual and departmental KPIs was associated with improved ADR and overall performance throughout the 8-year study period. Concomitant monitoring of ADR and PDR may prevent 'gaming' behaviour and ensure that genuine improvement is achieved.
Collapse
Affiliation(s)
- Samuel Lim
- Department of Gastroenterology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Giovanni Tritto
- Department of Gastroenterology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Sebastian Zeki
- Department of Gastroenterology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Sabina DeMartino
- Department of Gastroenterology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| |
Collapse
|
3
|
Toyoshima O, Nishizawa T, Yoshida S, Sekiba K, Kataoka Y, Hata K, Watanabe H, Tsuji Y, Koike K. Expert endoscopists with high adenoma detection rates frequently detect diminutive adenomas in proximal colon. Endosc Int Open 2020; 8:E775-E782. [PMID: 32490163 PMCID: PMC7247898 DOI: 10.1055/a-1136-9971] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Accepted: 03/02/2020] [Indexed: 02/07/2023] Open
Abstract
Background and study aims Adenoma detection rate (ADR) is an important quality indicator in colonoscopy, and improved ADR decreases the incidence of colorectal cancer. We investigated differences in polyp detection according to the endoscopist's ADR. Patients and methods We performed a propensity-score matching study using baseline patient characteristics of age, sex, body mass index, family history of colorectal cancer, smoking, drinking, indication for colonoscopy, bowel preparation, and colonoscope type. We compared polyp detection and colonoscopy procedures between patients who underwent colonoscopy by high-ADR endoscopists (high ADR group) and by low-ADR endoscopists (low ADR group). Results We matched 334 patients in the high ADR group with 334 in the low ADR group. The ADR was 44.0 % and 26.9 % for the high-ADR and low-ADR endoscopists, respectively. Proximal, nonprotruding, and diminutive adenomas were more frequently detected by high-ADR endoscopists than by low-ADR endoscopists (all P < 0.001); similarly, more high-risk adenomas were detected by high-ADR endoscopists ( P = 0.028). Furthermore, more sessile serrated polyps detected by high-ADR endoscopists ( P = 0.041). High-ADR endoscopists more frequently performed pancolonic chromoendoscopy ( P < 0.001). Conclusions Expert detectors often found nonprotruding and diminutive adenomas in the proximal colon along with increased detection rate of high-risk adenomas. Low-ADR endoscopists need to recognize the features of missed adenomas to improve their ADRs.
Collapse
Affiliation(s)
- Osamu Toyoshima
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Toshihiro Nishizawa
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Gastroenterology and Hepatology, International University of Health and Welfare, Mita Hospital, Tokyo, Japan
| | - Shuntaro Yoshida
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Kazuma Sekiba
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Yosuke Kataoka
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Gastroenterology, Sanraku Hospital, Chiyoda-ku, Japan
| | - Keisuke Hata
- Gastroenterology, Toyoshima Endoscopy Clinic, Tokyo, Japan,Department of Surgical Oncology, Graduate School of Medicine, The University of Tokyo, Japan
| | | | - Yosuke Tsuji
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| | - Kazuhiko Koike
- Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokoyo, Japan
| |
Collapse
|