1
|
Singh S, Suresh Kumar VC, Aswath G, Akbar Khan HM, Sapkota B, Vinayek R, Dutta S, Dahiya DS, Inamdar S, Mohan BP, Sharma N, Adler DG. Indirect comparison of various lumen-apposing metal stents for EUS-guided biliary and gallbladder drainage: a systematic review and meta-analysis. Gastrointest Endosc 2024:S0016-5107(24)03261-9. [PMID: 38851453 DOI: 10.1016/j.gie.2024.05.024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/30/2024] [Accepted: 05/31/2024] [Indexed: 06/10/2024]
Abstract
BACKGROUND AND AIMS Studies assessing EUS-guided biliary drainage (EUS-BD) or gallbladder drainage (EUS-GB) using lumen-apposing metal stents (LAMSs) have shown variable results based on the type of LAMS. We performed a meta-analysis of the available data. METHODS Multiple online databases were searched for studies using LAMSs (Axios [Boston Scientific, Marlborough, Mass, USA] or Spaxus [Taewoong Medical Co, Gimpo, Korea]) for EUS-BD and EUS-GB. The outcomes of interest were technical success, clinical success, and adverse events. Pooled proportions along with 95% confidence intervals were calculated. RESULTS A total of 18 observational studies were included: 11 for the Axios stent (433 patients; mean age, 72 years; 54% male) and 7 for the Spaxus stent (242 patients; mean age, 74 years; 50% male). The respective pooled outcomes for the Axios stent (EUS-BD and EUS-GB, respectively) were technical success, 96.2% and 96.2%; clinical success, 92.8% and 92.7%; total adverse events, 10.1% and 23.6%; and bleeding, 3.7% and 4.8%. The respective pooled outcomes for the Spaxus stent (EUS-BD and EUS-GB, respectively) were technical success, 93.8% and 95.9%; clinical success, 90.1% and 94.2%; total adverse events, 12.6% and 9.5%; and bleeding, 3.1% and 1.8%. CONCLUSIONS Axios and Spaxus stents demonstrate similar pooled technical and clinical success rates. Adverse events occurred in 23.6% of patients (Axios stent) and 9.5% of patients (Spaxus stent) during EUS-GB.
Collapse
Affiliation(s)
- Sahib Singh
- Internal Medicine, Sinai Hospital of Baltimore, Baltimore, Maryland, USA
| | - Vishnu Charan Suresh Kumar
- Gastroenterology and Hepatology, State University of New York Upstate Medical University, Syracuse, New York, New York, USA
| | - Ganesh Aswath
- Gastroenterology and Hepatology, State University of New York Upstate Medical University, Syracuse, New York, New York, USA
| | - Hafiz Muzaffar Akbar Khan
- Gastroenterology and Hepatology, State University of New York Upstate Medical University, Syracuse, New York, New York, USA
| | - Bishnu Sapkota
- Gastroenterology and Hepatology, State University of New York Upstate Medical University, Syracuse, New York, New York, USA
| | - Rakesh Vinayek
- Gastroenterology and Hepatology, Sinai Hospital of Baltimore, Baltimore, Maryland, USA
| | - Sudhir Dutta
- Gastroenterology and Hepatology, Sinai Hospital of Baltimore, Baltimore, Maryland, USA
| | - Dushyant Singh Dahiya
- Gastroenterology and Hepatology, The University of Kansas School of Medicine, Kansas City, Kansas, USA
| | - Sumant Inamdar
- Gastroenterology and Hepatology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Babu P Mohan
- Gastroenterology and Hepatology, Orlando Gastroenterology PA, Orlando, Florida, USA
| | - Neil Sharma
- Gastroenterology and Hepatology, Parkview Health, Fort Wayne, Indiana, USA
| | - Douglas G Adler
- Gastroenterology and Hepatology, Centura Health at Porter Adventist Hospital, Denver, Colorado, USA.
| |
Collapse
|
2
|
Nimri F, Ichkhanian Y, Shinn B, Kowalski TE, Loren DE, Kumar A, Schlachterman A, Tantau A, Arevalo M, Taha A, Shamaa O, Viales MC, Khashab MA, Simmer S, Singla S, Piraka C, Zuchelli TE. Comprehensive analysis of adverse events associated with transmural use of LAMS in patients with liver cirrhosis: International multicenter study. Endosc Int Open 2024; 12:E740-E749. [PMID: 38847015 PMCID: PMC11156515 DOI: 10.1055/a-2312-1528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 04/16/2024] [Indexed: 06/09/2024] Open
Abstract
Background and study aims Endoscopic ultrasound (EUS)-guided transmural (TM) deployment of lumen-apposing metal stents (LAMS) is considered relatively safe in non-cirrhotic patients and is cautiously offered to cirrhotic patients. Patients and methods This was a retrospective, multicenter, international matched case-control study to study the safety of EUS-guided TM deployment of LAMS in cirrhotic patients. Results Forty-three cirrhotic patients with model for end-stage liver disease score 12.5 ± 5, with 23 having ascites and 16 with varices underwent EUS-guided TM LAMS deployment, including 19 for pancreatic fluid collection (PFC) drainage, 13 gallbladder drainage, six for endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP), three for EDGI, one for endoscopic ultrasound-directed transenteric ERCP, and one postsurgical collection drainage. Technical failure occurred in one LAMS for PFC drainage. Clinical failure was encountered in another PFC. Nine adverse events (AEs) occurred. The most common AE was LAMS migration (3), followed by non-bleeding mucosal erosion (2), delayed bleeding (2), sepsis (1), and anesthesia-related complication (pulseless electrical activity) (1). Most AEs were graded as mild (6), followed by severe (2), and moderate (1); the majority were managed conservatively. On univariable comparison, risk of AE was higher when using a 20 × 10 mm LAMS and the absence of through-the-LAMS plastic stent(s). Conditional logistic regression of matched case-control patients did not show any association between potential predicting factors and occurrence of AEs. Conclusions Our study demonstrated that mainly in patients with Child-Pugh scores A and B cirrhosis and despite the presence of mild-to-moderate ascites in over half of cases, the majority of AEs were mild and could be managed conservatively. Further studies are warranted to verify the safety of LAMS in cirrhotic patients.
Collapse
Affiliation(s)
- Faisal Nimri
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Yervant Ichkhanian
- Department of Internal Medicine, Henry Ford Hospital, Detroit, United States
| | - Brianna Shinn
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Thomas E. Kowalski
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - David E. Loren
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Anand Kumar
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Alexander Schlachterman
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Alina Tantau
- Division of Gastroenterology and Hepatology Medical Center, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Martha Arevalo
- Instituto Ecuatoriano de Enfermedades Digestivas (IECED), Guayaquil, Ecuador
| | - Ashraf Taha
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Omar Shamaa
- Department of Internal Medicine, Henry Ford Hospital, Detroit, United States
| | | | - Mouen A. Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, United States
| | - Stephen Simmer
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Sumit Singla
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Cyrus Piraka
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Tobias E. Zuchelli
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| |
Collapse
|
3
|
Pérez-Cuadrado Robles E, Perrod G, Rahmi G. Guessing the future of endoscopic drainage of walled-off necrosis. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2020; 112:426-428. [PMID: 32496127 DOI: 10.17235/reed.2020.7252/2020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The endoscopic treatment of walled-off necrosis is rapidly evolving concurrently with an increasing number of endoscopic techniques, devices, and combined procedures. Thus, there is a growing armamentarium of alternatives for those patients in whom the conventional direct endoscopic necrosectomy is not enough. However, when the patient reaches this point he enters in an unexplored field and choosing the correct option can be challenging. Furthermore, there is no consensus on the number of endoscopic procedures to perform before considering that direct endoscopic necrosectomy has failed and therefore another strategy should be considered.
Collapse
Affiliation(s)
| | | | - Gabriel Rahmi
- Gastroenterology, Georges-Pompidou European Hospital, France
| |
Collapse
|
4
|
Pérez-Cuadrado Robles E, Prat F, Deprez PH. Endoscopic ultrasound-guided drainage with lumen-apposing metal stents: a good safety profile also in the long term? REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2019; 111:416-418. [PMID: 31081671 DOI: 10.17235/reed.2019.6348/2019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Lumen-apposing metal stents (LAMSs) have been specifically designed for the endoscopic drainage of pancreatic fluid collections and walled-off necrosis. Lately, LAMS indications have expandedto other anastomoses, and these stents have proven to be effective in multiple situations. Safety data for this device are still limited, most studies to date being focused on intraoperative complications and not long-term issues. There are little data regarding the best timing for removal and the risks associated in leaving them in place for long duration. In addition, not all the procedure-related complications have the same clinical impact, and the settings in which LAMS have been used are heterogeneous, leading to different safety profiles and outcomes. A wide consensus on the definition of complications and a list of key performance measures for LAMS placement seems mandatory to allow for a robust assessment of their long-term outcomes.
Collapse
Affiliation(s)
| | | | - Pierre H Deprez
- Gastroenterology, Cliniques universitaires Saint-Luc, Belgium
| |
Collapse
|