1
|
Whang WJ, Yun J, Koh K. Intense pulsed-light treatment improves objective optical quality in patients with meibomian gland dysfunction. BMC Ophthalmol 2023; 23:191. [PMID: 37118666 PMCID: PMC10148435 DOI: 10.1186/s12886-023-02939-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 04/22/2023] [Indexed: 04/30/2023] Open
Abstract
BACKGROUND To evaluate changes in objective optical quality following intense pulsed light (IPL) treatment combined with meibomian gland (MG) expression (MGX) in patients with MG dysfunction (MGD). METHODS This retrospective cross-sectional study included MGD-related dry eye disease (DED) patients who received IPL treatment between March and December 2021 at Kim's Eye Hospital, Seoul, Republic of Korea. Each patient underwent four sessions of IPL treatment using Lumenis M22 (Lumenis Ltd., Yokneam, Israel) and MGX at three-week intervals. RESULTS This study included 90 eyes from 45 patients with MGD. The mean age was 52.3 ± 16.1 years (range, 20-75 years), and 53.3% (24/45) of patients were female. Compared with the baseline, all clinical symptoms and signs significantly improved after IPL treatment combined with MGX. All optical quality parameters obtained with an optical quality analysis system (OQAS: Visiometrics, Castelldefels, Spain) have improved significantly over the baseline (p < 0.001). CONCLUSIONS In patients with MGD, IPL treatment combined with MGX improved the objective optical quality and clinical signs and symptoms of DED.
Collapse
Affiliation(s)
- Woong-Joo Whang
- Department of Ophthalmology, Yeouido St. Mary's Hospital, The Catholic University College of Medicine, Seoul, Republic of Korea
| | - Jeongseop Yun
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| | - Kyungmin Koh
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
2
|
Liao X, Li JY, Tan QQ, Tian J, Lin J, Lan CJ. Comparison of visual quality after implantation of A1-UV and SN60WF aspheric intraocular lens. Int J Ophthalmol 2020; 13:1727-1732. [PMID: 33215002 DOI: 10.18240/ijo.2020.11.07] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 08/27/2020] [Indexed: 12/22/2022] Open
Abstract
AIM To compare the visual performance of pseudophakic eyes implanted with A1-UV and SN60WF aspheric intraocular lens (IOL), and to investigate the correlations between visual quality parameters and pupil size. METHODS This prospective comparative study included 105 eyes of 90 patients with age-related cataract who underwent uneventful phacoemulsification. The subjects were divided into two groups according to the implanted IOL type. Three months postoperatively, visual acuity and contrast sensitivity were measured, wave-front aberrations were assessed using a KR-1W aberrometer (Topcon), and objective optical quality parameters were performed using an optical quality analysis system-OQAS II (Visiometrics). Independent sample t-test and Spearman correlation analysis were used for data analysis. RESULTS There were no significant differences found in visual acuity, contrast sensitivity and visual quality parameters between the two groups (P>0.05). The measured intraocular spherical aberration (SA) in A1-UV IOL eyes of -0.19±0.05 µm was close to the designed SA value of -0.20 µm. The modulation transfer function cutoff, Strehl ratio and OQAS values were negatively correlated with pupil size in both groups (P<0.01). CONCLUSION The subjective and objective visual quality in pseudophakic eyes with A1-UV and SN60WF IOLs are comparable. For aspheric IOL eyes, visual quality decreases with increasing pupil size.
Collapse
Affiliation(s)
- Xuan Liao
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Ji-Yun Li
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology, the First People's Hospital of Neijiang, Neijiang 641000, Sichuan Province, China
| | - Qing-Qing Tan
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Jing Tian
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Jia Lin
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Chang-Jun Lan
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| |
Collapse
|
3
|
Fernández J, Rodríguez-Vallejo M, Martínez J, Burguera N, Piñero DP. Agreement between subjective and predicted high and low contrast visual acuities with a double-pass system. Graefes Arch Clin Exp Ophthalmol 2020; 259:1651-1657. [PMID: 33128671 DOI: 10.1007/s00417-020-04987-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 09/23/2020] [Accepted: 10/20/2020] [Indexed: 10/23/2022] Open
Abstract
PURPOSE To evaluate the agreement between subjective high and low contrast visual acuity (VA) and predicted values from double-pass system measurements in healthy candidates to laser refractive surgery. METHODS Ninety-two eyes measured during the preoperative screening to laser refractive surgery were included in this retrospective analysis. High contrast subjective visual acuity (HCVA) and low contrasts at 20% (LCVA20) and 9% (LCVA9) were compared with the predicted VA obtained with a commercial double-pass system (OQAS) at the same levels of contrast, 100% (OV100), 20% (OV20), and 9% (OV9). The agreement was evaluated with Bland-Altman analysis computing the limits of agreement (LoAs) and the correlations with the spearman rho. RESULTS An underestimation of VA was obtained with the double-pass system for the highest contrast. Differences between predictive and subjective measurements were statistically significant for 100% contrast (- 0.08 logMAR, p < 0.0005), but not for 20% (- 0.03 logMAR, p = 0.07) and 9% (- 0.02 logMAR, p = 0.9) of contrasts. The LoAs increased with the decrease of contrast from 0.29 with 100% to 0.39 logMAR with 9% of contrast. A weak correlation was obtained between subjective and predicted VA (rho ≤ 0.33) that was only significant for 100% (p = 0.001) and 20% (p = 0.004) contrasts. CONCLUSION Mean differences between methods were reasonably small so mean results obtained for predicted VA in OQAS studies can be considered as reliable, at least in healthy subjects and for low contrast. However, limits of agreement were considerably poor which means that OQAS cannot replace individual subjective measurements of VA in clinical practice.
Collapse
Affiliation(s)
- Joaquín Fernández
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | | | - Javier Martínez
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | - Noemi Burguera
- Department of Ophthalmology (Qvision), Vithas Virgen del Mar Hospital, 04120, Almería, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.,Department of Ophthalmology (IMQO-Oftalmar), Vithas Medimar International Hospital, Alicante, Spain
| |
Collapse
|