1
|
Batu Eken Z, Ilie N. A Critical Review on the Factors Affecting the Bond Strength of Direct Restorative Material Alternatives to Amalgam. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4853. [PMID: 39410424 PMCID: PMC11478171 DOI: 10.3390/ma17194853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/07/2024] [Revised: 09/27/2024] [Accepted: 09/28/2024] [Indexed: 10/20/2024]
Abstract
This article comprehensively reviews the performance of simplified direct restorative materials that have the potential to be an alternative to amalgam. Following an understanding of the material structures and clinical performances, this review provides an analysis of the bonding mechanisms and influential factors on the bond strength. These factors include substrate-related variations, involving primary vs. permanent dentin, sound- vs. caries-affected/demineralized dentin comparisons and surface-related factors and pretreatments. Special attention is given to the factors changing the substrate surface, such as different contaminants, remedy methods after contamination and different conditioning methods related to the materials. Variations in sample preparation and bond strength test parameters are also evaluated for the analysis of the outcomes. This review aims to provide an overview of the factors involved in the application procedure of direct restorations together with in vitro testing variations to guide the selection of suitable materials by understanding strengths and shortcomings.
Collapse
Affiliation(s)
- Zeynep Batu Eken
- Department of Conservative Dentistry and Periodontology, LMU University Hospital, LMU Munich, Goethestr. 70, 80336 Munich, Germany;
| | | |
Collapse
|
2
|
Marigo L, Triestino A, Castagnola R, Vincenzoni F, Cordaro M, Di Stasio E, Mordente A, Nocca G. Cytotoxic Evaluation of the New Composite Resin through an Artificial Pulp Chamber. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5100816. [PMID: 36440368 PMCID: PMC9683947 DOI: 10.1155/2022/5100816] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 11/02/2022] [Accepted: 11/07/2022] [Indexed: 11/27/2023]
Abstract
The aim of this study was to analyse the cytocompatibility of Surefil One (SuO) with respect to the release of monomers from the material. The following reference materials were chosen: SDR Flow Plus (SDR, Dentsply Sirona, Konstanz, Germany), One Q Bond (Q, Dentalica, Milan, Italy), and Ketac (K, 3M-ESPE, USA). Fifteen dentin discs (2 mm thickness and diameter) were obtained from 15 third molars and were used in this study. After dentin disc permeability measurement, murine fibroblasts were grown, and the pulp surface of the dentinal disc was placed in direct contact with the cells immersed in DMEM. The experimental materials were positioned on the occlusal side of each dentinal disc until a uniform thickness of 2 mm was obtained. Then, the discs were inserted into an artificial pulp chamber for 24 hours to assess the cytocompatibility. Afterwards, the moles of monomers leached from the specimens in DMEM were determined using HPLC. Statistical analysis was performed using ANOVA (p < 0.05). Under the experimental conditions, the toxic effect induced by all tested materials was slight or absent. Diurethane dimethacrylate and acrylic acid were not found in the culture media. It is concluded that all materials have good cytocompatibility consistent with the nondeterminability of the monomers released after polymerization.
Collapse
Affiliation(s)
- Luca Marigo
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Alessio Triestino
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Raffaella Castagnola
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Federica Vincenzoni
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Massimo Cordaro
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo Agostino Gemelli 8, Rome 00168, Italy
- Dipartimento di Testa-Collo e Organi di Senso, Università Cattolica del Sacro Cuore, Largo Agostino Gemelli 8, Rome 00168, Italy
| | - Enrico Di Stasio
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Alvaro Mordente
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| | - Giuseppina Nocca
- Dipartimento di Scienze Biotecnologiche di Base, Cliniche Intensivologiche e Perioperatorie, Sezione di Biochimica, Università Cattolica del Sacro Cuore, Largo F. Vito, 1, 00168 Rome, Italy
- Fondazione Policlinico Universitario A. Gemelli, IRCCS, Largo A. Gemelli 8, 00168 Rome, Italy
| |
Collapse
|
3
|
David C, Cuevas-Suárez CE, de Cardoso GC, Isolan CP, de Moraes RR, da Rosa W, Münchow EA, da Silva AF. Characterization of Contemporary Conventional, Bulk-fill, and Self-adhesive Resin Composite Materials. Oper Dent 2022; 47:392-402. [PMID: 35917238 DOI: 10.2341/21-063-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/06/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To evaluate the physical and biological properties of different types of flowable resin composites and their bonding ability to dentin, comparing the performance of self-adhesive and bulk-fill materials with a conventional control. METHODS AND MATERIALS Four flowable resin composites were tested: two self-adhesive (Y-flow [SA_YF]; and Dyad Flow [SA_DF]); one bulk-fill (Filtek Bulk Fill Flow [BF]); and one conventional composite (Opallis Flow [OF]). The microshear bond strength (μSBS) to dentin (bovine samples) was investigated at 24 hours and 6 months of storage. The materials were also characterized by degree of conversion, cross-link density, water contact angle, color stability, and cell viability (ISO 10993-5/2009) analyses. Data were analyzed using Analysis of Variance and Tukey tests (α=0.05). RESULTS The μSBS values were higher for control specimens at 24 hours, whereas the resin-dentin bonds were similarly distributed among the groups after aging. Adhesive failure was the most frequent pattern observed at both time intervals. SA_YF was the only material that increased the bond strength over time. Degree of conversion increased in the following order: SA_YF (28.6±1.4%) < BF (49.7±0.8%) < OF (60.0±2.0%) = SA_DF (63.6±2.3%). Cross-link density was similar among all materials. The self-adhesive composites were more hydrophilic than the other types, with BF showing the lowest water contact angle and the greatest color alteration. All resin composites had a biocompatible behavior. CONCLUSION Chemical composition appeared to be an influential factor affecting the physicomechanical and biological behavior of the materials tested.
Collapse
Affiliation(s)
- C David
- Carla David, Biopathological Research Group, Faculty of Dentistry (GIBFO), University of the Andes Mérida, Mda, Venezuela; Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - C E Cuevas-Suárez
- Carlos Enrique Cuevas-Suárez, Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Pachuca, Hgo, Mexico
| | - G C de Cardoso
- Gabriela Cardoso de Cardoso, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - C P Isolan
- Cristina Pereira Isolan, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - R R de Moraes
- Rafael Ratto de Moraes, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - Wlo da Rosa
- Wellington Luiz Oliveira da Rosa, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| | - E A Münchow
- Eliseu A Münchow, Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, POA, RS, Brazil
| | - A F da Silva
- *Adriana Fernandes da Silva, Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil
| |
Collapse
|
4
|
Iaculli F, Salucci A, Di Giorgio G, Luzzi V, Ierardo G, Polimeni A, Bossù M. Bond Strength of Self-Adhesive Flowable Composites and Glass Ionomer Cements to Primary Teeth: A Systematic Review and Meta-Analysis of In Vitro Studies. MATERIALS 2021; 14:ma14216694. [PMID: 34772221 PMCID: PMC8586968 DOI: 10.3390/ma14216694] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 10/25/2021] [Accepted: 11/04/2021] [Indexed: 11/17/2022]
Abstract
Background: Conventional composites are largely used in pediatric restorative dentistry and demonstrate successful clinical outcomes. However, the need for simplification of operative steps in young or uncooperative children demands reliable alternatives. Therefore, the aim of the present systematic review and meta-analysis was to evaluate the in vitro bond strength of glass ionomer cements (GICs) and self-adhesive flowable composites (SFCs) on deciduous teeth. Methods: A comprehensive literature search according to the PRISMA checklist was manually and electronically performed by two independent reviewers through the following databases: MEDLINE/PubMed, Google Scholar, Scopus, and Embase, to include in vitro studies comparing GICs and SFCs bond strength values of restorations on primary teeth. In addition, three groups of meta-analyses were conducted using random-effects models. Results: Three articles meeting the inclusion criteria were selected and subjected to both qualitative and quantitative assessment. No statistically significant difference was found between SFC versus GIC; however, both groups significantly differed with conventional flowable composites (CFs). Conclusions: Despite the absence of significant difference in bond strength values, SFCs may be considered a valid alternative to GICs in the restoration of deciduous teeth, although CFs proved better in vitro performances.
Collapse
Affiliation(s)
- Flavia Iaculli
- Department of Neuroscience and Reproductive and Odontostomatological Sciences, University of Naples Federico II, 80131 Naples, Italy;
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Alessandro Salucci
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Gianni Di Giorgio
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
- Correspondence:
| | - Valeria Luzzi
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Gaetano Ierardo
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Antonella Polimeni
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| | - Maurizio Bossù
- Department of Oral and Maxillofacial Science, “Sapienza” University of Rome, 00161 Rome, Italy; (A.S.); (V.L.); (G.I.); (A.P.); (M.B.)
| |
Collapse
|
5
|
Rheological Properties, Surface Microhardness, and Dentin Shear Bond Strength of Resin-Modified Glass Ionomer Cements Containing Methacrylate-Functionalized Polyacids and Spherical Pre-Reacted Glass Fillers. J Funct Biomater 2021; 12:jfb12030042. [PMID: 34287317 PMCID: PMC8293056 DOI: 10.3390/jfb12030042] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 07/03/2021] [Accepted: 07/08/2021] [Indexed: 01/08/2023] Open
Abstract
The aim of this study was to prepare experimental resin-modified glass ionomer cements (RMGICs) containing low levels of hydroxyethyl methacrylate (HEMA) for pulp protection. Liquid and powder phases of the experimental RMGICs were polyacid functionalized with methacrylate groups and spherical pre-reacted glass fillers (SPG). Two types of liquid phase containing 0 wt. % HEMA (CM liquid) or 5 wt. % HEMA (CMH liquid) were formulated. The experimental RMGICs were prepared by mixing SPG fillers with CM liquid (F1) or CMH liquid (F2). Rheological properties were examined using a strain-controlled rheometer (n = 5). The Vickers microhardness (n = 5) and dentin shear bond strength (SBS) (n = 10) of the materials were tested. Commercial pulp protection materials (Vitrebond and TheraCal LC) were used as comparisons. The viscosity and surface microhardness of F1 (22 m Pa·s, 18 VHN) and F2 (18 m Pa·s, 16 VHN) were significantly higher than those of Vitrebond (6 mPa·s, 6 VHN) and TheraCal (0.1 mPa·s, 7 VHN). The SBS of F1 (10.7 MPa) and F2 (11.9 MPa) was comparable to that of Vitrebond (15.4 MPa) but higher than that of TheraCal LC (5.6 MPa). The addition of 5 wt. % HEMA showed no significant effect on viscosity, surface microhardness, or SBS of the experimental RMGICs. The experimental materials showed higher viscosity and microhardness but similar SBS when compared with the commercial RMGIC.
Collapse
|
6
|
Zarabian T, Azadi Mood S, Kiomarsi N, Noorollahian H, Hakimiha N. Microshear Bond Strength of a Self-adhesive Composite to Erbium Laser-Treated Primary Enamel. J Lasers Med Sci 2020; 11:181-186. [PMID: 32273960 DOI: 10.34172/jlms.2020.30] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: Advances have been made in the composition of flowable composites in recent years and self-adhering composites, which do not require a bonding agent, have recently been introduced to the market. This study aimed to assess the microshear bond strength (µSBS) of a self-adhering flowable composite (Vertise) to primary enamel treated with a graphite disc with silicon carbide particles (SIC) and laser irradiation, the result of which was compared to that of a conventional flowable composite (Premise). Methods: In this in vitro, experimental study, 72 samples of sound primary enamel were evaluated. A smooth enamel surface was obtained using a graphite disc. Next, the erbium chromium yttrium scandium gallium garnet (Er,Cr:YSGG) laser was used for enamel surface treatment in half of the samples (n=36). All the samples were then randomly divided into 4 groups of (i) Premise flowable composite (PF) without laser (n=18), (ii) Vertise flowable composite (VF) without laser (n=18), (iii) PF with laser (n=18), and (iv) VF with laser (n=18). The teeth were then incubated at 37°C for 24 hours and were then subjected to thermocycling. The µSBS of samples was measured using a universal testing machine and reported in megapascal (MPa). Data were analyzed using SPSS via the two-way ANOVA and independent-samples t test at P<0.05. Results: The mean µSBS of VF was significantly higher to the laser-treated samples (13.60±5.47) compared with the non-treated samples (5.89±2.42) (P<0.001). However, no significant difference was noted in the µSBS of PF to the laser-treated (13.18±3.45) and non-treated samples (16.06±3.52) (P=0.058). Conclusion: The µSBS of the conventional flowable composite is higher than that of the self-adhering flowable composite to the enamel of primary teeth. Enamel surface treatment with laser irradiation increases the µSBS of self-adhering flowable composites.
Collapse
Affiliation(s)
- Tara Zarabian
- Department of Pediatric Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Saba Azadi Mood
- Dentist, Tehran University of Medical Sciences, Tehran, Iran
| | - Nazanin Kiomarsi
- Department of Operative Dentistry, Dental Faculty, Tehran University of Medical Sciences, International Campus, Tehran, Iran
| | - Homa Noorollahian
- Department of Pediatric Dentistry, Dental Faculty, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Neda Hakimiha
- Laser Research Center of Dentistry, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|