He Y, Chen H, Zhang H, Grimm R, Zhao C, Guo X, Liu Y, Yuan Z. Optimization of scan parameters to reduce acquisition time for RESOLVE-based diffusion kurtosis imaging (DKI) in nasopharyngeal carcinoma (NPC).
Br J Radiol 2022;
95:20210641. [PMID:
35704453 PMCID:
PMC10162055 DOI:
10.1259/bjr.20210641]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 03/10/2022] [Accepted: 05/23/2022] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE
To shorten acquisition time of readout segmentation of long variable echo trains (RESOLVE)-based diffusion kurtosis imaging (DKI) via Readout Partial Fourier (RPF) and b-value combinations.
METHODS
The RESOLVE-based DKI images of 38 patients with nasopharyngeal carcinoma (NPC) were prospectively enrolled. For RESOLVE-based DKI images with 5/8 RPF and without RPF, objective and subjective evaluations of image quality were performed. A total of nine groups with different b-value combinations were simulated, and the influence of different b-value combinations for RESOLVE-RPF-based DKI sequences was assessed using the intraclass correlation coefficient (ICC).
RESULTS
The mean values of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in DKI images without RPF were higher than those with 5/8 RPF (252.9 ± 77.7 vs 247.3 ± 85.5 and 5.8 ± 2.8 vs 5.4 ± 2.3, respectively), but not significantly (p = 0.460 and p = 0.180, respectively). In comparing the ICCs between nine groups of different b-value combinations in RESOLVE-RPF-based DKI, group (200, 800, 2000 s/mm2), group (200, 400, 800, 2000 s/mm2) and group (200, 800, 1500, 2000 s/mm2) were not significantly different (p > 0.001) and showed excellent agreement (0.81-1.00) with that of group (200, 400, 800, 1500, 2000 s/mm2). Using b-value optimization and RPF technology, the group with RPF (200, 400, 800, 2000 s/mm2) showed a 56% reduced scanning compared with the group without RPF (200, 400, 800, 1500, 2000 s/mm2; 3 min 46 s vs 8 min 31 s, respectively).
CONCLUSION
DKI with RPF did not significantly affect image quality, but both RPF and different b-value combinations can affect the scanning time. The combination of RPF and b-value optimization can ensure the stability of DKI parameters and reduce the scanning time by 56%.
ADVANCES IN KNOWLEDGE
This work is to optimize scan parameters, e.g. RPF and b-value combinations, to reduce acquisition time for RESOLVE-based DKI in NPC. To our knowledge, the effect of RESOLVE-RPF and b-value combinations on DKI has not been reported.