1
|
Yu Y, Yang F, Qin M, Wei X, Yu S, Gong D, Wang G, Tang H, Xu Z. Experimental observation on a new chimney-shaped mechanical valve completely implanted above the mitral annulus in animals. Gen Thorac Cardiovasc Surg 2024; 72:149-156. [PMID: 37452910 DOI: 10.1007/s11748-023-01959-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Accepted: 07/03/2023] [Indexed: 07/18/2023]
Abstract
Current commercially available prosthetic valves suffer from limited size, high requirements for implantation technique, subvalvular structural destruction, and valve dysfunction due to proliferation of fibrous endothelial tissue. This study aims to perform the preclinical large animal experiments for surgically implanting a chimney-shaped artificial mechanical heart valve with zero left ventricular occupancy, which fully accommodates the movement of the valve leaflets in the valve frame and realizes completely supra-annular surgical implantation. A total of 7 sheep underwent the replacement of artificial valve, and 5 sheep survived normally until anatomical examination. The mechanical properties of these artificial mitral valves remain functionally normal. There was no obvious thromboembolism around the artificial valve and in the important organs. The tissue layer of suture ring was completely organized and endothelialized, and the thickness of tissue layer was about 0.6-1.0 mm. The follow-up of echocardiography showed that the left ventricular ejection fraction was normal (60-70%) before and 6 months after operation. The results of transvalvular pressure gradient and blood flow velocity of artificial valve were normal. Left ventricular retrograde angiography showed that the artificial valve was completely located in the left atrium with good position and normal opening and closing. There was no obvious perivalvular leakage and other abnormalities. At 3 and 6 months, there were no obvious abnormalities in blood routine test, liver and kidney function, and other indexes. The new chimney-shaped artificial mechanical valve implanted completely above the mitral annulus had good wear resistance, histocompatibility, and antithrombotic and hemodynamic performance.
Collapse
Affiliation(s)
- Yongchao Yu
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Fan Yang
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Ming Qin
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Xufeng Wei
- Experimental Animal Center of China Medical Town, Taizhou, 225300, Jiangsu, China
| | - Shangyi Yu
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Dejun Gong
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China
| | - Guokun Wang
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
- Department of Cardiovascular Surgery, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, Zhejiang, China.
| | - Hao Tang
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
| | - Zhiyun Xu
- Department of Cardiovascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, 200433, China.
| |
Collapse
|
2
|
Bruno VD, Di Tommaso E, Ascione R. Annuloplasty for mitral valve repair in degenerative disease: to be flexible or to be rigid? That's still the question. Indian J Thorac Cardiovasc Surg 2020; 36:563-565. [PMID: 33093751 PMCID: PMC7572951 DOI: 10.1007/s12055-020-01001-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 06/23/2020] [Indexed: 11/11/2022] Open
Abstract
The choice of ring for mitral valve repair is still largely left to the surgeon's preferences and there are no specific guidelines regulating this decision. Despite this previous researches have described important features appertaining to each of the different types of rings currently available. Particularly, the debate is still open in regards to the flexibility that these devices should or should not have. Later in this issue of the Journal, Panicker and colleagues have reported their results with flexible and rigid rings in mitral valve repair. The results are very interesting and once again are highlighting the importance of using the right ring for the right disease.
Collapse
Affiliation(s)
- Vito Domenico Bruno
- Translational Health Science, Faculty of Health Science, Bristol Heart Institute, University of Bristol Medical School, Marlborough Street, Bristol, BS2 8HW UK
| | - Ettorino Di Tommaso
- Translational Health Science, Faculty of Health Science, Bristol Heart Institute, University of Bristol Medical School, Marlborough Street, Bristol, BS2 8HW UK
| | - Raimondo Ascione
- Translational Health Science, Faculty of Health Science, Bristol Heart Institute, University of Bristol Medical School, Marlborough Street, Bristol, BS2 8HW UK
| |
Collapse
|