da Fonte JBM, Fontenele RC, Farias-Gomes A, Ruiz DC, Andrade-Bortoletto MFS, Sousa Melo SL, Freitas DQ. Do the number of zirconia implants and the thickness of CBCT image reconstruction affect the detection of peri-implant bone defect? A diagnostic accuracy ex vivo study. Clin Oral Implants Res 2024. [PMID: 39072795 DOI: 10.1111/clr.14336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 06/12/2024] [Accepted: 07/09/2024] [Indexed: 07/30/2024]
Abstract
OBJECTIVES To evaluate the influence of multiplanar reconstruction thickness on the detection of peri-implant bone defects with a standalone zirconia implant and compare it to when another implant is in the vicinity using cone-beam computed tomography (CBCT). MATERIALS AND METHODS Five dry human mandibles were used to create twenty implant sites in the second premolar and first molar regions. The OP300 Maxio was used to acquire CBCT images (90 kVp, 6.3 mA, 5 × 5 cm FOV, and 0.125 mm3 voxel size) before and after creating 3 mm peri-implant bone defects in the buccal aspect of the premolar region. Half of the scans featured a single zirconia implant in the premolar region, while the others had two implants in the premolar and molar regions. Three reconstruction thicknesses (0.125 mm, 1 mm, and 2 mm) were considered for the multiplanar reconstruction analyses. Five oral and maxillofacial radiologists assessed the detection of peri-implant bone defects using a 5-point scale. Diagnostic parameters were calculated and compared using Two-way ANOVA (α = .05). RESULTS The studied factors showed no significant influence on the diagnosis of peri-implant bone defects (p > .05). Diagnostic performance was notably higher with a single implant, especially with a 2-mm reconstruction thickness (AUC = 0.88, sensitivity = 0.68, specificity = 0.94). Although the differences were not statistically significant, the results were more modest when two implants were present (AUC = 0.80, sensitivity = 0.58, specificity = 0.82). CONCLUSIONS The presence of an adjacent zirconia implant and variations in reconstruction thickness did not influence the detection of 3 mm buccal peri-implant bone defects on CBCT images.
Collapse
Affiliation(s)
- Juliana Batista Melo da Fonte
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
- Department of Oral and Maxillofacial Diagnostic Sciences, School of Dental Medicine, University of Connecticut, Farmington, Connecticut, USA
| | - Rocharles Cavalcante Fontenele
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven and Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Amanda Farias-Gomes
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | - Débora Costa Ruiz
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| | | | - Saulo L Sousa Melo
- Department of Oral and Craniofacial Sciences, School of Dentistry, Oregon Health & Science University, Portland, Oregon, USA
| | - Deborah Queiroz Freitas
- Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil
| |
Collapse
|
2
|
Jacobs R, Fontenele RC, Lahoud P, Shujaat S, Bornstein MM. Radiographic diagnosis of periodontal diseases - Current evidence versus innovations. Periodontol 2000 2024. [PMID: 38831570 DOI: 10.1111/prd.12580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 04/23/2024] [Accepted: 05/16/2024] [Indexed: 06/05/2024]
Abstract
Accurate diagnosis of periodontal and peri-implant diseases relies significantly on radiographic examination, especially for assessing alveolar bone levels, bone defect morphology, and bone quality. This narrative review aimed to comprehensively outline the current state-of-the-art in radiographic diagnosis of alveolar bone diseases, covering both two-dimensional (2D) and three-dimensional (3D) modalities. Additionally, this review explores recent technological advances in periodontal imaging diagnosis, focusing on their potential integration into clinical practice. Clinical probing and intraoral radiography, while crucial, encounter limitations in effectively assessing complex periodontal bone defects. Recognizing these challenges, 3D imaging modalities, such as cone beam computed tomography (CBCT), have been explored for a more comprehensive understanding of periodontal structures. The significance of the radiographic assessment approach is evidenced by its ability to offer an objective and standardized means of evaluating hard tissues, reducing variability associated with manual clinical measurements and contributing to a more precise diagnosis of periodontal health. However, clinicians should be aware of challenges related to CBCT imaging assessment, including beam-hardening artifacts generated by the high-density materials present in the field of view, which might affect image quality. Integration of digital technologies, such as artificial intelligence-based tools in intraoral radiography software, the enhances the diagnostic process. The overarching recommendation is a judicious combination of CBCT and digital intraoral radiography for enhanced periodontal bone assessment. Therefore, it is crucial for clinicians to weigh the benefits against the risks associated with higher radiation exposure on a case-by-case basis, prioritizing patient safety and treatment outcomes.
Collapse
Affiliation(s)
- Reinhilde Jacobs
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
- Department of Dental Medicine, Karolinska Institute, Stockholm, Sweden
| | - Rocharles Cavalcante Fontenele
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Pierre Lahoud
- OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium
- Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
- Periodontology and Oral Microbiology, Department of Oral Health Sciences, KU Leuven, Leuven, Belgium
| | - Sohaib Shujaat
- King Abdullah International Medical Research Center, Department of Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia
| | - Michael M Bornstein
- Department of Oral Health & Medicine, University Center for Dental Medicine Basel UZB, University of Basel, Basel, Switzerland
| |
Collapse
|
3
|
Costa JA, Mendes JM, Salazar F, Pacheco JJ, Rompante P, Câmara MI. Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review. Oral Radiol 2023:10.1007/s11282-023-00683-w. [PMID: 37058184 DOI: 10.1007/s11282-023-00683-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 03/30/2023] [Indexed: 04/15/2023]
Abstract
The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.
Collapse
Affiliation(s)
- J A Costa
- Medicine and Oral Surgery Department, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.
| | - J M Mendes
- UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| | - F Salazar
- UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| | - J J Pacheco
- UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| | - P Rompante
- UNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| | - M I Câmara
- Medicine and Oral Surgery Department, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal
| |
Collapse
|
4
|
Miotk N, Schwindling FS, Zidan M, Juerchott A, Rammelsberg P, Hosseini Z, Nittka M, Heiland S, Bendszus M, Hilgenfeld T. Reliability and accuracy of intraoral radiography, cone beam CT, and dental MRI for evaluation of peri-implant bone lesions at zirconia implants - an ex vivo feasibility study. J Dent 2023; 130:104422. [PMID: 36649822 DOI: 10.1016/j.jdent.2023.104422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVES To determine the reliability and accuracy of intraoral radiography (IR), cone-beam-computed tomography (CBCT), and dental magnetic resonance imaging (dMRI) in measuring peri‑implant bone defects around single zirconia implants. METHODS Twenty-four zirconia implants were inserted in bovine ribs with various peri‑implant defect sizes and morphologies. True defect extent was measured without implant in CBCT. Defects were measured twice in IR, CBCT, and dMRI with the inserted implant by three experienced readers. Reliability was assessed by ICC, accuracy by the Friedman test, and post-hoc-Tukey's test. RESULTS A comparable good to excellent intra- and inter-reader reliability was observed for all modalities (intra-/inter-rater-CC range for IR; CBCT; dMRI: 0.81-0.91/0.79;0.87-0.97/0.96;0.87-0.95/0.94). Accuracy was generally high, with mean errors below 1 mm in all directions. However, measuring defect depth in the mesiodistal direction was significantly more accurate in dMRI (0.65 ± 0.38 mm) compared to IR (2.71 ± 1.91 mm), and CBCT (1.98 ± 1.97 mm), p-values ≤ 0.0001 respectively ≤ 0.01. CONCLUSIONS Osseous defects around zirconia implants can be reliably measured in IR/CBCT/dMRI in the mesiodistal directions. In addition, CBCT and dMRI allow assessment of the buccolingual directions. dMRI provides a comparable accuracy in all directions, except for the mesiodistal defect depth, where it outperforms IR and CBCT.
Collapse
Affiliation(s)
- Nikolai Miotk
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Franz Sebastian Schwindling
- Department of Prosthodontics, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Moussa Zidan
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Alexander Juerchott
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Peter Rammelsberg
- Department of Prosthodontics, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Zahra Hosseini
- MRI-sequence developer, Magnetic Resonance R&D Collaborations, Siemens Medical Solutions, Atlanta, 3139 Mae Ave NE, Atlanta, GA - Georgia 30319, United States.
| | - Mathias Nittka
- MRI-sequence developer, Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Enkestraße 127, Erlangen 91052, Germany.
| | - Sabine Heiland
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Martin Bendszus
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| | - Tim Hilgenfeld
- Department of Neuroradiology, Heidelberg University Hospital, Im Neuenheimer Feld 400, Heidelberg 69120, Germany.
| |
Collapse
|
5
|
Cavalcanti MGP, Salineiro FC, Barros FM, Barros FBA. Influence of endodontic sealers artifacts in the detection of vertical root fractures. Braz Dent J 2022; 33:22-30. [DOI: 10.1590/0103-6440202204392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 11/25/2021] [Indexed: 11/22/2022] Open
Abstract
Abstract The aim of this study was to compare the influence of endodontic sealers artifacts on the detection of vertical root fracture in cone beam computed tomography (CBCT). Premolars and central incisors were assigned into five different groups: Control, Pulp Canal Sealer, AH Plus, Sealer 26, and BC Sealer (n= 10, per group). VRFs were mechanically induced and the teeth were inserted into an image phantom. Subsequently, CBCT (Cranex 3Dx, Soredex, Tuusula, Finland) images were obtained and two observers were asked separately to identify root fracture, by visual analysis. For both premolar and central incisors, kappa coefficients of intraobserver agreement varied from good to excellent (K: 80% - 87%), and the values for interobserver agreement varied from fair to moderate (K: 30% - 35%). As follows, the area under the curve (AUC) of receiver operating characteristic (ROC) values for VRFs highlighted that the use of BC sealer reduced the observers’ ability to discriminate VRFs relative to other sealers. Moreover, sensitivity values for premolars teeth ranged from 20% to 60%, and specificity ranged from 60% to 100%; while sensitivity values for central incisors ranged from 30% to 70%, and specificity ranged from 70% to 100%. In conclusion, the low sensitivity values, mainly for premolars, demonstrated the difficulty in VRF diagnosis. Furthermore, BC Sealer induced significantly more imaging artifacts than other sealers. These results highlighting that endodontic sealers may interfere with the diagnosis of VRFs.
Collapse
|
6
|
Chagas MM, Kobayashi-Velasco S, Gimenez T, Cavalcanti MGP. Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis. Imaging Sci Dent 2022; 51:363-372. [PMID: 34987996 PMCID: PMC8695475 DOI: 10.5624/isd.20210120] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 09/08/2021] [Accepted: 09/24/2021] [Indexed: 12/21/2022] Open
Abstract
Purpose This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. Materials and Methods Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. Results The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects (0.73) and fenestration defects (0.87) showed a statistically significant difference. Conclusion The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.
Collapse
Affiliation(s)
- Mariana Murai Chagas
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | - Thais Gimenez
- Graduate Program in Dentistry, Ibirapuera University, São Paulo, São Paulo, Brazil
| | | |
Collapse
|
7
|
Diagnostic performance of periapical and panoramic radiography and cone beam computed tomography for detection of circumferential gaps simulating osseointegration failure around dental implants: A systematic review. Oral Surg Oral Med Oral Pathol Oral Radiol 2021; 132:e208-e222. [PMID: 34580020 DOI: 10.1016/j.oooo.2021.08.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 08/12/2021] [Accepted: 08/17/2021] [Indexed: 01/17/2023]
Abstract
OBJECTIVE The objective of this study was to appraise the diagnostic performance of periapical (PR) and panoramic (PANO) radiographs and cone beam computed tomography (CBCT) in detecting artificial circumferential gaps simulating osseointegration failure around dental implants in ex vivo studies. STUDY DESIGN Seven electronic databases and three gray literature sources were searched. Studies reporting diagnostic performance measures or data allowing calculation of those measures compared with the reference standard of in situ direct measurements were considered eligible. Either the area under the receiver operating characteristic curve or accuracy was chosen to summarize findings, with diagnostic performance interpreted as poor, acceptable, excellent, or outstanding. Risk of bias (RoB) was also assessed. RESULTS The ten included studies mostly suggested overall excellent to outstanding diagnostic capability with PR and CBCT. Various enhancement filters, CBCT voxel sizes, and/or fields of view were associated with acceptable to outstanding efficacy. PANO had the poorest results, with most research demonstrating acceptable to excellent discrimination. The RoB was high for seven studies, moderate for two, and low for -one. CONCLUSIONS PR and CBCT images were generally superior to PANO for the detection of artificial bone gaps. Results should be interpreted with caution because most studies had a high RoB.
Collapse
|
8
|
Zhang CN, Zhu Y, Fan LF, Zhang X, Jiang YH, Gu YX. Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study. J Dent Sci 2020; 16:948-956. [PMID: 34141109 PMCID: PMC8189872 DOI: 10.1016/j.jds.2020.10.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 10/28/2020] [Indexed: 11/30/2022] Open
Abstract
Background/purpose Information regarding agreements between periapical radiograph (PA) and cone beam computed tomography (CBCT) in detecting peri-implant defect is still scarce. The aim of this clinical study was to compare agreements between PA and CBCT in detecting peri-implant bone defect. Materials and methods This retrospective clinical study enrolled 32 patients with both PA and CBCT filmed right after implant placement. Four modalities were used for film reading: PA1 (original), PA2 (enhanced brightness/contrast), CBCT1 (selected axial and mesial-distal direction images) and CBCT2 (all data with software). 2 experienced and 2 inexperienced observers scored all films. Intra- and inter-observer agreements were estimated with Cohen's kappa coefficient. Categorized agreements were compared and differences among four modalities were calculated. Results Agreements of PA were better than CBCT when detecting peri-implant bone defects in inter-observer agreements (median kappa 0.471 vs. 0.192; p = 0.016). Moreover, agreements in experienced observers were better than inexperienced observers (median kappa 0.883 vs. 0.567; p < 0.001). There was significant difference among four modalities except for experienced observer 2 (p = 0.218). Conclusion Agreements of PA are better than CBCT when detecting peri-implant bone defects, especially for inter-observer agreements. Experienced observers are more consistent in assessment than inexperienced ones.
Collapse
Affiliation(s)
- Chu-Nan Zhang
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yu Zhu
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Lin-Feng Fan
- Department of Radiology, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiao Zhang
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| | - Yin-Hua Jiang
- Department of Oral and Maxillofacial Implantology, Lishui Sixth People's Hospital, Wenzhou Medical University, Lishui, China
| | - Ying-Xin Gu
- Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University School of Medicine; National Clinical Research Center for Oral Diseases; Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China
| |
Collapse
|
9
|
Kim JH, Abdala-Júnior R, Munhoz L, Cortes ARG, Watanabe PCA, Costa C, Arita ES. Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects. Imaging Sci Dent 2020; 50:133-139. [PMID: 32601588 PMCID: PMC7314605 DOI: 10.5624/isd.2020.50.2.133] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2019] [Revised: 04/12/2020] [Accepted: 04/24/2020] [Indexed: 12/01/2022] Open
Abstract
Purpose This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mechanically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm×8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm×8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results High intraobserver and interobserver agreement was found (P<0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56±0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss.
Collapse
Affiliation(s)
- Jun Ho Kim
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Reinaldo Abdala-Júnior
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Luciana Munhoz
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Arthur Rodriguez Gonzalez Cortes
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil.,Department of Dental Surgery, Faculty of Dental Surgery, University of Malta, Mater Dei Hospital, Msida, Malta
| | - Plauto Christopher Aranha Watanabe
- Department of Stomatology, Field of Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirao Preto, Brazil
| | - Claudio Costa
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Emiko Saito Arita
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
10
|
Vandenberghe B. The crucial role of imaging in digital dentistry. Dent Mater 2020; 36:581-591. [PMID: 32299666 DOI: 10.1016/j.dental.2020.03.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 03/09/2020] [Indexed: 10/24/2022]
Abstract
One of the recent trends in dentistry - and this in every field from the restorative to the orthodontic one- is the introduction of simplified completely digital workflows. Digital dentistry is supposed to allow dentists to work more efficiently, and this at higher precision, and with the possibility of all-in-one sessions using in-house computerized techniques. In this workflow, one of the major tools for simulating and transferring dental treatments is imaging. Both 3D low dose radiographic as well as optical imaging are playing crucial roles and have been overwhelming the market. Novel design platforms, compact and extremely fast milling and printing units are now also plentiful and rapidly being adopted in practice. Nevertheless, many of the steps in this digital dentistry process, no matter how simplified, present risks that can contribute to reduced precision and clinical difficulties. It is therefore the purpose of the article to briefly describe the role of imaging in this digital workflow, and where the pitfalls can be found that may lead to errors and imprecision.
Collapse
Affiliation(s)
- Bart Vandenberghe
- Advimago, Center for Advanced Oral Imaging, Emile Clausstraat 42, 1050 Brussels, Belgium.
| |
Collapse
|
11
|
Vadiati Saberi B, Khosravifard N, Ghandari F, Hadinezhad A. Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection. Imaging Sci Dent 2019; 49:265-272. [PMID: 31915611 PMCID: PMC6941830 DOI: 10.5624/isd.2019.49.4.265] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 09/03/2019] [Accepted: 09/18/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel (PPA) and oblique projected periapical (OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects (10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects (P<0.05). Conclusion The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.
Collapse
Affiliation(s)
- Bardia Vadiati Saberi
- Dental Sciences Research Center, Department of Periodontics, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Negar Khosravifard
- Dental Sciences Research Center, Department of Maxillofacial Radiology, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Farnaz Ghandari
- Department of Maxillofacial Radiology, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| | - Arash Hadinezhad
- Department of Maxillofacial Radiology, School of Dentistry, Guilan University of Medical Sciences, Rasht, Iran
| |
Collapse
|
12
|
Isman O, Aktan AM, Ertas ET. Evaluating the effects of orthodontic materials, field of view, and artifact reduction mode on accuracy of CBCT-based caries detection. Clin Oral Investig 2019; 24:2487-2496. [PMID: 31811495 DOI: 10.1007/s00784-019-03112-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 10/07/2019] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To investigate the influence of orthodontic materials, field of view (FOV), and artifact reduction (AR) on the assessment of approximal caries using cone beam computed tomography. MATERIALS AND METHODS Forty non-cavitated and restoration-free human premolars and molars ranging from sound to various grades of lesions without cavitations were assigned to 13 groups with different combination of fix appliance equipment. CBCT (cone beam computed tomography) (Planmeca ProMax 3D Mid, Helsinki, Finland) images were obtained using combinations of three orthodontic bracket materials and two orthodontic archwire with small and large FOVs and with and without AR activation. Receiver operating characteristic (ROC) analysis was used to calculate the area under the ROC curve (AUC). RESULTS Interobserver agreement ranged from 0.44 to 0.92 and intraobserver agreement ranged from 0.50 to 0.99. Teeth lacking orthodontic materials had the highest Az values at 0.84. FOV and AR activation did not significantly affect AUC values (P > 0.05). The AUC data were significantly reduced by the addition of stainless steel wire, NT wire, or a combination of a stainless steel bracket with stainless steel wire (P < 0.05). CONCLUSIONS The addition of stainless steel wire, NT wire, or a stainless steel bracket with stainless steel wire combination prevented the diagnosis of non-cavitated interproximal tooth caries by CBCT. With and without AR modes and different FOVs did not influence the diagnosis of interproximal caries lesions with different types of orthodontic equipment. CLINICAL RELEVANCE A wide variety of brackets and wire combinations are used in the clinic; however, the extent to which these combinations impact the diagnosis of caries by CBCT as the effects of FOV and AR algorithms are unknown.
Collapse
Affiliation(s)
- Ozlem Isman
- Vocational High School of Health Service, Gaziantep University, 27310, Şehitkamil, Gaziantep, Turkey.
| | | | | |
Collapse
|
13
|
Jia P, Yang G, Hu W, Chung KH, Zhao Y, Liu M, Chen CS. Comparison of in situ cone beam computed tomography scan data with ex vivo optical scan data in the measurement of root surface area. Oral Surg Oral Med Oral Pathol Oral Radiol 2019; 128:552-557. [PMID: 31171483 DOI: 10.1016/j.oooo.2019.05.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2018] [Revised: 04/27/2019] [Accepted: 05/13/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVE The aim of this study was to compare root surface area (RSA) measurements of single-root teeth in a sheep mandible based on cone beam computed tomography (CBCT) with measurements made with an optical scanner. STUDY DESIGN Eight anterior teeth of a sheep cadaver mandible were scanned in situ by using CBCT with 3 different exposure parameters, followed by treatment with smoothing software. The teeth were then extracted and scanned individually with an optical scanner. Three-dimensional digital models of the teeth were reconstructed on the basis of CBCT and optical scanner data. RSA data were calculated, and an equivalence test was used to statistically compare the measurements with significance of difference established at α = 0.05. RESULTS The means of the differences between RSA measurements from CBCT and optical scanning ranged from 0.33% to 3.01%. There were no statistically significant differences between the 2 methods. The smoothing parameters for good fitness of the linear regression were determined to be 0.8 for the smooth factor, 8 for iterations, and 0 for compensate shrinkage. CONCLUSIONS The proposed CBCT technique to measure RSA is feasible. RSA data obtained from CBCT in situ are as accurate as optical scanner measurements ex vivo.
Collapse
Affiliation(s)
- Pengcheng Jia
- Department of Periodontology & Second Clinical Division, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China. Pengcheng Jia is now employed in Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China
| | - Gang Yang
- Department of Periodontology & Second Clinical Division, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China. Pengcheng Jia is now employed in Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China
| | - Wenjie Hu
- Department of Periodontology & Second Clinical Division, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China. Pengcheng Jia is now employed in Second Clinical Division, Peking University School and Hospital of Stomatology, Beijing, China.
| | - Kwok-Hung Chung
- Department of Restorative Dentistry, University of Washington, Seattle, WA, USA
| | - Yijiao Zhao
- Center of Digital Dentistry, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Muqing Liu
- Department of Oral & Maxillofacial Radiology, Peking University School and Hospital of Stomatology, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Beijing, China
| | - Curtis Sk Chen
- Division of Oral Radiology, Department of Oral Medicine, School of Dentistry, University of Washington, Seattle, WA, USA
| |
Collapse
|
14
|
Bohner L, Habor D, Gremse F, Tortamano P, Wolfart S, Marotti J. Accuracy of High-Frequency Ultrasound Scanner in Detecting Peri-implant Bone Defects. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:650-659. [PMID: 30593434 DOI: 10.1016/j.ultrasmedbio.2018.10.030] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 10/21/2018] [Accepted: 10/29/2018] [Indexed: 06/09/2023]
Abstract
The purpose of this study was to assess the accuracy of high-frequency ultrasound (US) in the measurement of peri-implant bone defects in comparison with cone-beam computed tomography (CBCT) and micro-computed tomography (µCT). Bone defects were mechanically created around dental implants inserted into porcine ribs (n = 10). The bone samples were scanned by CBCT, µCT and US. Linear dimensions of the peri-implant defects were determined for supra-alveolar component, intra-bony component and width. The accuracy of measurements was evaluated with repeated-measures analysis of variance and the intra-class correlation coefficient at p ≤ 0.05. US underestimated the measurements for the supra-alveolar and intra-bony components in comparison to CBCT and µCT, and there were no statistically significant differences in the measurements of width. The intra-class correlation coefficient of US ranged from 0.96 to 0.98, whereas that for CBCT ranged from 0.77 to 0.97. US was accurate in measuring the width of peri-implant defects, although vertical measurements were underestimated by approximately 1 mm in comparison to those of CBCT and µCT.
Collapse
Affiliation(s)
- Lauren Bohner
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Aachen, Germany; Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Daniel Habor
- Chair of Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Felix Gremse
- Department of Experimental Molecular Imaging, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Pedro Tortamano
- Department of Prosthodontics, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Stefan Wolfart
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Aachen, Germany
| | - Juliana Marotti
- Department of Prosthodontics and Biomaterials, Centre for Implantology, Medical School of the RWTH Aachen University, Aachen, Germany.
| |
Collapse
|
15
|
Etiology and Measurement of Peri-Implant Crestal Bone Loss (CBL). J Clin Med 2019; 8:jcm8020166. [PMID: 30717189 PMCID: PMC6406263 DOI: 10.3390/jcm8020166] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 01/22/2019] [Accepted: 01/24/2019] [Indexed: 12/15/2022] Open
Abstract
The etiology of peri-implant crestal bone loss is today better understood and certain factors proposed in the past have turned out to not be of concern. Regardless, the incidence of crestal bone loss remains higher than necessary and this paper reviews current theory on the etiology with a special emphasis on traditional and innovative methods to assess the level of crestal bone around dental implants that will enable greater sensitivity and specificity and significantly reduce variability in bone loss measurement.
Collapse
|
16
|
Dach E, Bergauer B, Seidel A, von Wilmowsky C, Adler W, Lell M, Wichmann M, Matta RE. Impact of voxel size and scan time on the accuracy of three-dimensional radiological imaging data from cone-beam computed tomography. J Craniomaxillofac Surg 2018; 46:2190-2196. [PMID: 30318325 DOI: 10.1016/j.jcms.2018.09.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 06/06/2018] [Accepted: 09/10/2018] [Indexed: 12/18/2022] Open
Abstract
PURPOSE Three-dimensional (3D) radiological imaging plays an important role in surgical planning used in modern dentistry. The aim of this study was to optimize imaging parameters with a special focus on voxel size and scan time. MATERIAL AND METHODS A virtual 3D master model of a macerated human skull was generated using an industrial optical noncontact white light scanner. The skull was X-rayed with cone-beam computed tomography that was applied using different settings for voxel size and acquisition time (voxel edge length of 0.3 mm, scan times 4.8 s and 8.9 s; voxel edge length of 0.2 mm, scan times 14.7 s and 26.9 s). The scan was repeated 10 times at each setting. The CBCT scans were converted into 3D virtual models (actual value), which were superimposed with the 3D master model (reference value) to detect absolute differences. RESULTS The mean value of deviation increased with increasing voxel size and decreasing scan time. For a voxel edge length of 0.3 mm, the mean values of deviation were 0.33 mm and 0.22 mm with scan times of 4.8 s and 8.9 s, respectively. For a voxel edge length of 0.2 mm, the mean deviations were 0.16 mm and 0.14 mm with scan times of 14.7 s and 26.9 s, respectively. CONCLUSIONS When using small voxel sizes, the scan time does not have a significant impact on image accuracy and therefore the scan time can be shortened. However, for larger voxel sizes, shorter scan times can lead to increased inaccuracy.
Collapse
Affiliation(s)
- Eva Dach
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Bastian Bergauer
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Anna Seidel
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Cornelius von Wilmowsky
- Department of Oral and Maxillofacial Surgery (Head: Professor Dr. med. Dr. med. Dent. M. Kesting), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Werner Adler
- Department of Medical Informatics, Biometry and Epidemiology (Head: Professor Dr. O. Gefeller), Friedrich-Alexander-University of Erlangen-Nürnberg, Universitätsstraße 22, 91054, Erlangen, Germany
| | - Michael Lell
- Institute of Radiology and Nuclear Medicine (Head: Professor Dr. M. Lell), Klinikum Nürnberg, Paracelsus Medical University, Prof.-Ernst-Nathan-Straße 1, 90419, Nürnberg, Germany
| | - Manfred Wichmann
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany
| | - Ragai-Edward Matta
- Department of Prosthodontics (Head: Professor Dr. M. Wichmann), Erlangen University Hospital, Glückstraße 11, 91054, Erlangen, Germany.
| |
Collapse
|
17
|
Hilgenfeld T, Juerchott A, Deisenhofer UK, Krisam J, Rammelsberg P, Heiland S, Bendszus M, Schwindling FS. Accuracy of cone-beam computed tomography, dental magnetic resonance imaging, and intraoral radiography for detecting peri-implant bone defects at single zirconia implants-An in vitro study. Clin Oral Implants Res 2018; 29:922-930. [PMID: 30112833 DOI: 10.1111/clr.13348] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Revised: 07/09/2018] [Accepted: 07/09/2018] [Indexed: 12/26/2022]
Abstract
OBJECTIVES To evaluate the diagnostic value of cone-beam computed tomography (CBCT), intraoral radiography (IR), and dental magnetic resonance imaging (dMRI) for detecting and classifying peri-implant bone defects at zirconia implants. MATERIALS AND METHODS Forty-eight zirconia implants were inserted in bovine ribs, 24 of which had standardized defects (1-wall, 2-wall, 3-wall, 4-wall) in two sizes (1 and 3 mm). CBCT, IR, and dMRI were performed and analyzed twice by four readers unaware of the nature of the defects. Cohen's and Fleiss' kappa (κ), sensitivity, and specificity were calculated for the presence/absence of bone defects, defect size, and defect type. Cochran's Q-test with post hoc McNemar was used to test for statistical differences. RESULTS A high intra- and inter-reader reliability (κ range: 0.832-1) and sensitivity/specificity (IR: 0.97/0.96; CBCT: 0.99/1; dMRI: 1/0.99) for bone defect detection were observed for all three imaging methods. For defect type classification, intra- (κ range: 0.505-0.778) and inter-reader (κ: 0.411) reliability of IR were lower compared to CBCT (κ range intrareader: 0.667-0.889; κ inter-reader: 0.629) and dMRI (κ range intrareader: 0.61-0.832; κ inter-reader: 0.712). The sensitivity for correct defect type classification was not significantly different for CBCT (0.81) and dMRI (0.83; p = 1), but was significantly lower for IR (0.68; vs. CBCT p = 0.003; vs. dMRI p = 0.004). The sensitivity advantage of CBCT and dMRI for defect classification was smaller for 1-mm defects (CBCT/dMRI/IR: 0.68/0.72/0.63, no significant difference) than for 3-mm defects (CBCT/dMRI/IR: 0.95/0.94/0.74; CBCT vs. IR p = 0.0001; dMRI vs. IR p = 0.003). CONCLUSION Within the limitations of an in vitro study, IR can be recommended as the initial imaging method for evaluating peri-implant bone defects at zirconia implants. CBCT provides higher diagnostic accuracy of defect classification at the expense of higher cost and radiation dose. Dental MRI may be a promising imaging method for evaluating peri-implant bone defects at zirconia implants in the future.
Collapse
Affiliation(s)
- Tim Hilgenfeld
- Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Alexander Juerchott
- Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | | | - Johannes Krisam
- Institute for Medical Biometry and Informatics, Heidelberg University Hospital, Heidelberg, Germany
| | - Peter Rammelsberg
- Department of Prosthodontics, Heidelberg University Hospital, Heidelberg, Germany
| | - Sabine Heiland
- Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Martin Bendszus
- Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | | |
Collapse
|
18
|
Pelekos G, Acharya A, Tonetti MS, Bornstein MM. Diagnostic performance of cone beam computed tomography in assessing peri-implant bone loss: A systematic review. Clin Oral Implants Res 2018; 29:443-464. [PMID: 29578266 DOI: 10.1111/clr.13143] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/17/2018] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To evaluate the diagnostic performance of cone beam computed tomography (CBCT) in the assessment of peri-implant bone loss and analyze its influencing factors. MATERIALS AND METHODS Clinical and preclinical studies reporting diagnostic outcomes of CBCT imaging of peri-implant bone loss compared to direct reference measurements were sought by searching five electronic databases, PubMed, MEDLINE, EMBASE, Web of Science, and CINAHL Plus, and OpenGrey. QUADAS-2 criteria were adapted for quality analysis of the included studies. A qualitative synthesis was performed. Two meta-analysis models (random-effects and mixed-effects) summarized the area under receiver operating characteristic (AUC) curve observations reported in the selected studies. The mixed-effects meta-analysis model evaluated three possible influencing factors, "defect type," "defect size," and "study effect." RESULTS The initial search yielded 3,716 titles, from which 18 studies (13 in vitro and 5 animal) were included. Diagnostic accuracy of CBCT was fair to excellent in detecting in vitro circumferential-intrabony and fenestration defects, but moderate to low for peri-implant dehiscences, and tended to be higher for larger defect sizes. Both, over- and underestimation of linear measurements were reported for the animal models. The meta-analyses included 37 AUC observations from eight studies. The random-effects model showed significant heterogeneity. The mixed-effects model exhibited also significant but lower heterogeneity, and "defect type" and "study effect" significantly influenced the variability of AUC observations. CONCLUSION In vitro, CBCT performs well in detecting peri-implant circumferential-intrabony or fenestration defects but less in depicting dehiscences. Influencing factors due to other site-related and technical parameters on the diagnostic outcome need to be addressed further in the future studies.
Collapse
Affiliation(s)
- Georgios Pelekos
- Periodontology, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Aneesha Acharya
- Department of Periodontology, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pune, India
- Implant Dentistry, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Maurizio S Tonetti
- Periodontology, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| | - Michael M Bornstein
- Oral and Maxillofacial Radiology, Applied Oral Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
19
|
|
20
|
Aimetti M, Manavella V, Corano L, Ercoli E, Bignardi C, Romano F. Three-dimensional analysis of bone remodeling following ridge augmentation of compromised extraction sockets in periodontitis patients: A randomized controlled study. Clin Oral Implants Res 2017; 29:202-214. [PMID: 29148597 DOI: 10.1111/clr.13099] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2017] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The aim of this study was to analyze linear and volumetric hard tissue changes in severely resorbed alveolar sockets after ridge augmentation procedure and to compare them with spontaneous healing using three-dimensional cone beam computed tomography (CBCT). MATERIAL AND METHODS Thirty patients (mean age 53.2 ± 6.3 years) requiring tooth extraction for advanced periodontitis were randomly allocated to test and control groups. The test sites were grafted using a collagenated bovine-derived bone (DBBM-C) covered with a collagen membrane, while control sites had spontaneous healing. Both groups healed by secondary intention. Linear and volumetric measurements were taken on superimposed CBCT images obtained after tooth extraction and 12 months later. RESULTS Greater horizontal shrinkage, localized mainly in the crestal zone, was observed in the control group (4.92 ± 2.45 mm) compared to the test group (2.60 ± 1.24 mm). While both groups presented a rebuilding of the buccal wall, it was most pronounced in the grafted sockets (2.50 ± 2.12 mm vs. 0.51 ± 1.02 mm). A significant difference was also registered in the percentage of volume loss between grafted and non-grafted sites (9.14% vs. 35.16%, p-value <.0001). CONCLUSION Alveolar sockets with extensive buccal bone deficiencies undergo significant three-dimensional volumetric alterations following natural healing. The immediate application of a slow-resorbing xenograft with a covering collagen membrane seems to be effective in improving alveolar ridge shape and dimensions, thus potentially reducing the need for adjunctive regenerative procedures at the time of implant placement.
Collapse
Affiliation(s)
- Mario Aimetti
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, Turin, Italy
| | - Valeria Manavella
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, Turin, Italy
| | | | - Elena Ercoli
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, Turin, Italy
| | - Cristina Bignardi
- Department of Mechanical and Aerospace Engineering, Politecnico of Torino, Turin, Italy
| | - Federica Romano
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, Turin, Italy
| |
Collapse
|
21
|
Salineiro FCS, Kobayashi-Velasco S, Braga MM, Cavalcanti MGP. Radiographic diagnosis of root fractures: a systematic review, meta-analyses and sources of heterogeneity. Dentomaxillofac Radiol 2017; 46:20170400. [PMID: 28749700 DOI: 10.1259/dmfr.20170400] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES Many studies to evaluate the accuracy of root fracture diagnosis have been conducted. However, there is a scarcity of studies to assess the quality and the sources of heterogeneity in the literature. For this reason, the aim of this study was to conduct systematic reviews and meta-analyses to summarize the available evidence on detection of root fractures by cone beam CT (CBCT) and periapical radiograph (PR) images and the interference of artefact by investigating possible sources of heterogeneity. METHODS Studies reporting root fracture detection, from January 2010 to February 2016, were selected. All selected studies were subjected to selection criteria and then, comparative and qualitative analyses by using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool were performed. Pooled sensitivity, specificity and diagnostic odds ratios were calculated. Also, receiver operator characteristics (ROC) curves were built to summarize the results. SROC curve analyses were performed to investigate the heterogeneity among studies. RESULTS Initially, 799 articles were selected. After screening titles and abstracts, 743 articles were excluded. After reading the remaining 56 full-texts, 47 relevant articles were included in this study. Diagnostic odds ratio values revealed a wide range of results across the studies and determined a higher heterogeneity for PR compared with CBCT. The analyses of the SROC curves compared CBCT imaging versus PR in the diagnosis of root fracture, favouring CBCT modality. CONCLUSIONS CBCT was the imaging exam that rendered a higher diagnostic accuracy for root fractures.
Collapse
Affiliation(s)
| | | | - Mariana Minatel Braga
- 2 Department of Pediatric Dentistry, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | |
Collapse
|
22
|
Bohner LOL, Mukai E, Oderich E, Porporatti AL, Pacheco-Pereira C, Tortamano P, De Luca Canto G. Comparative analysis of imaging techniques for diagnostic accuracy of peri-implant bone defects: a meta-analysis. Oral Surg Oral Med Oral Pathol Oral Radiol 2017; 124:432-440.e5. [DOI: 10.1016/j.oooo.2017.06.119] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2017] [Revised: 06/05/2017] [Accepted: 06/13/2017] [Indexed: 10/19/2022]
|
23
|
Rios HF, Borgnakke WS, Benavides E. The Use of Cone-Beam Computed Tomography in Management of Patients Requiring Dental Implants: An American Academy of Periodontology Best Evidence Review. J Periodontol 2017; 88:946-959. [DOI: 10.1902/jop.2017.160548] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
- Hector F. Rios
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI
| | - Wenche S. Borgnakke
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI
| | - Erika Benavides
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI
| |
Collapse
|
24
|
Salineiro FCS, Gialain IO, Kobayashi-Velasco S, Pannuti CM, Cavalcanti MGP. Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study. Imaging Sci Dent 2017; 47:17-24. [PMID: 28361025 PMCID: PMC5370246 DOI: 10.5624/isd.2017.47.1.17] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2016] [Revised: 09/19/2016] [Accepted: 10/31/2016] [Indexed: 11/18/2022] Open
Abstract
Purpose The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Materials and Methods Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. Results The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Conclusion Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.
Collapse
Affiliation(s)
| | - Ivan Onone Gialain
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | | - Claudio Mendes Pannuti
- Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | | |
Collapse
|