1
|
Visakh T, Priya PS, Panakkal NC, Banga G, Prakashini K. Correlation of patient characteristics with peak enhancement time for pediatric cardiac computed tomography in congenital heart disease. J Clin Imaging Sci 2024; 14:50. [PMID: 39777211 PMCID: PMC11704290 DOI: 10.25259/jcis_153_2024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2024] [Accepted: 12/08/2024] [Indexed: 01/11/2025] Open
Abstract
Objectives Cardiac computed tomography (CCT) plays a key role in diagnosing congenital heart disease (CHD), emphasizing the need for specialized protocols in newborns due to CHD's complexity. The aim is to explore the relationship between peak enhancement time (PET) and various parameters during CHD assessment with CCT. Material and Methods The study involved 38 CHD patients undergoing CCT, with observations made on their heart rate, respiratory rate, saturation, cardiac output, weight, height, and age. The PET for each case was determined, and Spearman's rank correlation was employed to evaluate the association between these parameters and the PET. Results The median PET was 20.63 s, with a mean aortic Hounsfield unit of 512.16 ± 160.56. A moderate negative correlation was found between PET and both heart rates (r = -0.42, P = 0.009) and respiratory rates (r = -0.41, P = 0.01), whereas a negligible positive correlation (r = 0.19, P = 0.25) was observed with SpO2. A moderate positive correlation was noted between PET and both weight (r = 0.44, P = 0.005) and height (r = 0.40, P = 0.01). In addition, there were significant differences in median PET across different age categories. Conclusion The findings conclude that PET during CCT is significantly associated with heart rate and respiratory rate. An increase in these rates corresponds to a notable decrease in PET. Consequently, the study recommends minimizing scan delays in CCT for patients exhibiting higher heart rates.
Collapse
Affiliation(s)
- T. Visakh
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - P. S. Priya
- Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Nitika C. Panakkal
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Gunjan Banga
- Department of Cardiology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Koteshwar Prakashini
- Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India
| |
Collapse
|
2
|
Ibrahim A, Guha S, Lu L, Geng P, Wu Q, Chou Y, Yang H, Wang D, Schwartz LH, Xie CM, Zhao B. The reproducibility and predictivity of radiomic features extracted from dynamic contrast-enhanced computed tomography of hepatocellular carcinoma. PLoS One 2024; 19:e0310486. [PMID: 39269960 PMCID: PMC11398651 DOI: 10.1371/journal.pone.0310486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 09/02/2024] [Indexed: 09/15/2024] Open
Abstract
PURPOSE To assess the reproducibility of radiomic features (RFs) extracted from dynamic contrast-enhanced computed tomography (DCE-CT) scans of patients diagnosed with hepatocellular carcinoma (HCC) with regards to inter-observer variability and acquisition timing after contrast injection. The predictive ability of reproducible RFs for differentiating between the degrees of HCC differentiation is also investigated. METHODS We analyzed a set of DCE-CT scans of 39 patients diagnosed with HCC. Two radiologists independently segmented the scans, and RFs were extracted from each sequence of the DCE-CT scans. The same lesion was segmented across the DCE-CT sequences of each patient's scan. From each lesion, 127 commonly used RFs were extracted. The reproducibility of RFs was assessed with regard to (i) inter-observer variability, by evaluating the reproducibility of RFs between the two radiologists; and (ii) timing of acquisition following contrast injection (inter- and intra-imaging phase). The reproducibility of RFs was assessed using the concordance correlation coefficient (CCC), with a cut-off value of 0.90. Reproducible RFs were used for building XGBoost classification models for the differentiation of HCC differentiation. RESULTS Inter-observer analyses across the different contrast-enhancement phases showed that the number of reproducible RFs was 29 (22.8%), 52 (40.9%), and 36 (28.3%) for the non-contrast enhanced, late arterial, and portal venous phases, respectively. Intra- and inter-sequence analyses revealed that the number of reproducible RFs ranged between 1 (0.8%) and 47 (37%), inversely related with time interval between the sequences. XGBoost algorithms built using reproducible RFs in each phase were found to be high predictive ability of the degree of HCC tumor differentiation. CONCLUSIONS The reproducibility of many RFs was significantly impacted by inter-observer variability, and a larger number of RFs were impacted by the difference in the time of acquisition after contrast injection. Our findings highlight the need for quality assessment to ensure that scans are analyzed in the same physiologic imaging phase in quantitative imaging studies, or that phase-wide reproducible RFs are selected. Overall, the study emphasizes the importance of reproducibility and quality control when using RFs as biomarkers for clinical applications.
Collapse
Affiliation(s)
- Abdalla Ibrahim
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| | - Siddharth Guha
- Department of Radiology, Columbia University Irving Medical Center, New York, New York, United States of America
| | - Lin Lu
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| | - Pengfei Geng
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| | - Qian Wu
- First Affiliated Hospital of Nanjing Medical University, Jiangsu, China
| | - Yen Chou
- Department of Medical Imaging, Fu Jen Catholic University Hospital, New Taipei City, Taiwan
| | - Hao Yang
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| | - Delin Wang
- Department of Radiology, Sun Yat-Sen University Cancer Center, Guangzhou, China
| | - Lawrence H. Schwartz
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| | - Chuan-miao Xie
- Department of Radiology, Sun Yat-Sen University Cancer Center, Guangzhou, China
| | - Binsheng Zhao
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America
| |
Collapse
|
3
|
Nguyen ET, Green CR, Adams SJ, Bishop H, Gleeton G, Hague CJ, Hanneman K, Harris S, Strzelczyk J, Dennie C. CAR and CSTR Cardiac Computed Tomography (CT) Practice Guidelines: Part 1 Coronary CT Angiography (CCTA). Can Assoc Radiol J 2024; 75:488-501. [PMID: 38486401 DOI: 10.1177/08465371241233240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2024] Open
Abstract
Imaging the heart is one of the most technically challenging applications of Computed Tomography (CT) due to the presence of cardiac motion limiting optimal visualization of small structures such as the coronary arteries. Electrocardiographic gating during CT data acquisition facilitates motion free imaging of the coronary arteries. Since publishing the first version of the Canadian Association of Radiologists (CAR) cardiac CT guidelines, many technological advances in CT hardware and software have emerged necessitating an update. The goal of these cardiac CT practice guidelines is to present an overview of the current evidence supporting the use of cardiac CT in various clinical scenarios and to outline standards of practice for patient safety and quality of care when establishing a cardiac CT program in Canada.
Collapse
Affiliation(s)
- Elsie T Nguyen
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | | | - Scott J Adams
- Department of Medical Imaging, Royal University Hospital, University of Saskatchewan, Saskatoon, Saskatchewan, Canada
| | - Helen Bishop
- Division of Cardiology, Department of Medicine, Dalhousie University, Halifax, NS, Canada
| | - Guylaine Gleeton
- Department of Radiology, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Laval University, Quebec City, QC, Canada
| | - Cameron J Hague
- Department of Diagnostic Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Kate Hanneman
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Scott Harris
- Department of Radiology, Memorial University, St. John's, NL, Canada
| | - Jacek Strzelczyk
- Department of Radiology, University of Manitoba, Winnipeg, MB, Canada
| | - Carole Dennie
- Department of Radiology, Radiation Oncology and Medical Physics, University of Ottawa, Ottawa, ON, Canada
| |
Collapse
|
4
|
Jayamani N, Pothiawala S, Ong HB, Low Choon Seng AS, Mohamed Afif A, Arumugam Z, Sung CT, Teck FC, Liang HC. Clinical audit of the image quality and customised contrast volume using P3T contrast injection software versus standard injection protocol in CT coronary angiography. Radiography (Lond) 2024; 30:1144-1150. [PMID: 38824873 DOI: 10.1016/j.radi.2024.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 04/23/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
INTRODUCTION The implications of shorter scan time and lower tube voltage in the dual-source CT coronary angiography (CTCA) scan protocol necessitate the adaptation of contrast media (CM) injection parameters. This audit evaluates the coronary arteries' vascular attenuation and image quality by comparing the personalised patient protocol technology (P3T) contrast injection software with standard injection protocol. The secondary aim is to determine the relationship between CM volume and the patient's weight. METHODOLOGY A Siemens Somatom Definition Force CT Unit was used to scan 30 sets of patients between August 2020 and October 2020. Patients were selected retrospectively and separated into Standard Injection and P3T injection protocols. An experienced radiologist blinded to the groups reviewed the coronary vessels' contrast enhancement and image quality. RESULTS Overall, the mean HU of all the main coronary artery vessels obtained from P3T injection software reached above 350 HU and was diagnostically sufficient. The mean attenuation at the proximal region of RCA in the 80-99 kg weight category was significantly higher in the P3T injection software than the standard injection protocol (p < 0.001). The CM volume proposed by P3T injection software for 40-59 kg was approximately 57 ± 5 mls, while 75 ml was used for the standard injection protocol. CONCLUSION P3T injection software in CTCA resulted in an adequate diagnostic attenuation of coronary arteries (>350HU) in all weight groups, most effectively in the higher weight group, while maintaining diagnostic image quality. Further, the P3T software reduces CM volumes in lower-weight patients. IMPLICATIONS P3T software enables reducing CM volume in lower-weight patients while improving vascular enhancement in CTCA scans in higher-weight patients.
Collapse
Affiliation(s)
- N Jayamani
- Department of Radiography, Singapore General Hospital, Singapore.
| | - S Pothiawala
- Department of Emergency Medicine, Woodlands Health, Singapore
| | - H B Ong
- Department of Radiography, Singapore General Hospital, Singapore
| | | | - A Mohamed Afif
- Department of Radiography, Singapore General Hospital, Singapore
| | - Z Arumugam
- Department of Radiography, Singapore General Hospital, Singapore
| | - C T Sung
- Department of Radiography, Singapore General Hospital, Singapore
| | - F C Teck
- Department of Radiography, Singapore General Hospital, Singapore
| | - H C Liang
- Department of Radiography, Singapore General Hospital, Singapore
| |
Collapse
|
5
|
Zucker EJ. Cardiac Computed Tomography in Congenital Heart Disease. Radiol Clin North Am 2024; 62:435-452. [PMID: 38553179 DOI: 10.1016/j.rcl.2023.12.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
Computed tomography (CT) has emerged as a leading imaging modality in the evaluation of congenital heart disease (CHD). With ever-faster acquisition speed, decreasing radiation exposure, impeccable anatomic detail, optional functional data, and numerous post-processing tools, CT offers broad utility in CHD diagnosis, preoperative planning, and postoperative assessment. In this article, the far-reaching role of CT in CHD is reviewed, focusing on technical imaging considerations and key clinical applications.
Collapse
Affiliation(s)
- Evan J Zucker
- Department of Radiology, Divisions of Pediatric and Cardiovascular Imaging, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA.
| |
Collapse
|
6
|
Randhawa MK, Sultana S, Stib MT, Nagpal P, Michel E, Hedgire S. Role of Radiology in Assessment of Postoperative Complications of Heart Transplantation. Radiol Clin North Am 2024; 62:453-471. [PMID: 38553180 DOI: 10.1016/j.rcl.2023.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
Heart transplantation is a pivotal treatment of end-stage heart failure, and recent advancements have extended median posttransplant life expectancy. However, despite the progress in surgical techniques and medical treatment, heart transplant patients still face complications such as rejection, infections, and drug toxicity. CT is a reliable tool for detecting most of these complications, whereas MR imaging is particularly adept at identifying pericardial pathologies and signs of rejection. Awareness of these nuances by radiologists, cardiologists, and surgeons is desired to optimize care, reduce morbidities, and enhance survival.
Collapse
Affiliation(s)
- Mangun K Randhawa
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Sadia Sultana
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Matthew T Stib
- Division of Cardiothoracic Imaging, Department of Radiology, Mayo Clinic Hospital, Phoenix, AZ, USA
| | - Prashant Nagpal
- Division of Cardiovascular Imaging, Department of Radiology, University of Wisconsin-Madison, Madison, WI, USA
| | - Eriberto Michel
- Division of Cardiac Surgery, Department of Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Sandeep Hedgire
- Division of Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.
| |
Collapse
|
7
|
Chen X, Jiang J, Zhang X. Automatic 3D coronary artery segmentation based on local region active contour model. J Thorac Dis 2024; 16:2563-2579. [PMID: 38738249 PMCID: PMC11087640 DOI: 10.21037/jtd-24-421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 04/17/2024] [Indexed: 05/14/2024]
Abstract
Background Segmentation of coronary arteries in computed tomography angiography (CTA) images plays a key role in the diagnosis and treatment of coronary-related diseases. However, manually analyzing the large amount of data is time-consuming, and interpreting this data requires the prior knowledge and expertise of radiologists. Therefore, an automatic method is needed to separate coronary arteries from a given CTA dataset. Methods Firstly, an anisotropic diffusion filter was employed to smooth the noise while preserving the vessel boundaries. The coronary skeleton was then extracted using a two-step process based on the intensity of the coronary. In the first step, the thick vessel skeleton was extracted by clustering, improved vesselness filtering and region growing, while in the second step, the thin vessel skeleton was extracted by the height ridge traversal method guided by the cylindrical model. Next, the vesselness measure, representing vessel a priori information, was incorporated into the local region active contour model based on the vessel geometry. Finally, the initial contour of the active contour model was generated using the coronary artery skeleton for effective segmentation of the three-dimensional (3D) coronary arteries. Results Experimental results on chest CTA images show that the method is able to segment coronary arteries effectively with an average precision, recall and dice similarity coefficient (DSC) of 86.64%, 91.26% and 79.13%, respectively, and has a good performance in thin vessel extraction. Conclusions The method does not require manual selection of vessel seeds or setting of initial contours, and allows for the extraction of a successful coronary artery skeleton and eventual effective segmentation of the coronary arteries.
Collapse
Affiliation(s)
- Xiaohong Chen
- Department of Ultrasound Medicine, The Second Affiliated Hospital of Nantong University, Nantong, China
| | - Jufeng Jiang
- School of Information Science and Technology, Nantong University, Nantong, China
| | - Xiaofeng Zhang
- School of Information Science and Technology, Nantong University, Nantong, China
| |
Collapse
|
8
|
Xiao H, Wang X, Yang P, Wang L, Xu J. Optimization of uniformity in coronary artery enhancement using a bolus tracking technique with a dual region of interest in coronary computed tomographic angiography. Acta Radiol 2024; 65:202-210. [PMID: 38059327 DOI: 10.1177/02841851231215421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/08/2023]
Abstract
BACKGROUND Consistent coronary artery enhancement is essential to achieve accurate and reproducible quantification of coronary plaque composition. PURPOSE To optimize coronary artery uniformity of enhancement using a bolus tracking technique with a dual region of interest (ROI) in coronary computed tomography angiography (CCTA) on a 320-detector CT scanner. MATERIAL AND METHODS This prospective study recruited 100 consecutive patients who underwent CCTA and were randomly divided into two groups, namely, a manual trigger group (n = 50), in which a manual fast start technique was used to start the diagnostic scan with the visual evaluation of attenuation in the left atrium and left ventricle, and an automatic trigger group (n = 50), in which a bolus tracking technique was used to automatically start the breath-holding command and diagnostic scan with two ROIs placed in the right and left ventricles. Coronary artery image quality was assessed using quantitative and qualitative scores. The enhancement uniformity was characterized by attenuation variability of the ascending aorta (AAO) and coronary arteries. RESULTS No statistically significant differences in the image quality of the coronary arteries were observed between the two groups (all P > 0.05). The coefficients of variation (COVs) of arterial attenuation in the automatic trigger group were significantly smaller than in the manual trigger group (AAO: 9.89% vs. 17.93%; LMA: 10.35% vs. 18.98%; LAD proximal: 12.09% vs. 20.84%; LCX proximal: 11.85% vs. 20.95%; RCA proximal: 12.13% vs. 20.84%; all P < 0.05). CONCLUSION The automatic trigger technique accompanied with dual ROI provides consistent coronary artery enhancement and optimizes coronary artery enhancement uniformity in CCTA on a 320-detector CT scanner.
Collapse
Affiliation(s)
- Huawei Xiao
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Xiangquan Wang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Panfeng Yang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Ling Wang
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Jian Xu
- Heart Center, Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China
| |
Collapse
|
9
|
Thrall JH, Brink JA, Zalis ME. The Environmental, Social, Governance Movement and Radiology: Opportunities and Strategy. J Am Coll Radiol 2024; 21:265-270. [PMID: 37495034 DOI: 10.1016/j.jacr.2023.02.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 12/20/2022] [Accepted: 02/07/2023] [Indexed: 07/28/2023]
Abstract
The environmental, social, governance (ESG) movement has come to health care organizations, in part through the Biden administration's challenge to them to reduce greenhouse gas emissions by 50% by 2030 and achieve net zero emissions by 2050, in support of more robust environmental sustainability. Radiology practices should become knowledgeable about ESG concepts and look for opportunities that are meaningful and achievable to support their host organizations' ESG efforts. Examples of initiatives to support improved environmental sustainability include selecting the least energy intensive imaging method for a given diagnosis, shutting down equipment in standby mode, sourcing energy from renewable sources, and reducing waste through recycling. Optimizing imaging protocols can reduce radiation exposure to patients, energy used per examination, and the use of other resources such as iodinated contrast media, an environmental pollutant. Achieving socially equitable access to services for ethnic and racial minorities remains a challenge in the US health care system. Extending hours of operation for screening services to include nights and weekends can provide options for patients who otherwise must take time away from work with loss of income. With respect to governance, more transparency in leadership selection and greater opportunities for participation by women and racial/ethnic minorities in the leadership of professional organizations should be supported in radiology. To succeed in ESG initiatives, radiology practice leaders should consider appointing a lead person and a multifunctional team that includes broad representation from the radiology workplace. The team should work to identify opportunities that are realistic and achievable within their institutional contexts.
Collapse
Affiliation(s)
- James H Thrall
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts; Subcommittee Chair, ACR Centennial Committee; Chair, Ethics in Publishing Subcommittee, ACR Publications Committee.
| | - James A Brink
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts; Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts; Chief, Enterprise Imaging, Mass General Brigham Health System; Radiologist-in-Chief, Massachusetts General Hospital
| | - Michael E Zalis
- Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts; Lead, Imaging Sustainability Task Force, Mass General Brigham Health System
| |
Collapse
|
10
|
Chamberlin JH, Baruah D, Smith C, McGuire A, Maisuria D, Kabakus IM. Cardiac Computed Tomography Protocols in Structural Heart Disease: A State-of-the-Art Review. Semin Roentgenol 2024; 59:7-19. [PMID: 38388099 DOI: 10.1053/j.ro.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/23/2023] [Accepted: 12/01/2023] [Indexed: 02/24/2024]
Affiliation(s)
- Jordan H Chamberlin
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhiraj Baruah
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC.
| | - Carter Smith
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Aaron McGuire
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Dhruw Maisuria
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Ismail M Kabakus
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| |
Collapse
|
11
|
Vernemmen I, Van Steenkiste G, Hauspie S, De Lange L, Buschmann E, Schauvliege S, Van den Broeck W, Decloedt A, Vanderperren K, van Loon G. Development of a three-dimensional computer model of the equine heart using a polyurethane casting technique and in vivo contrast-enhanced computed tomography. J Vet Cardiol 2023; 51:72-85. [PMID: 38101318 DOI: 10.1016/j.jvc.2023.11.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 11/13/2023] [Accepted: 11/16/2023] [Indexed: 12/17/2023]
Abstract
INTRODUCTION/OBJECTIVES Insight into the three-dimensional (3D) anatomy of the equine heart is essential in veterinary education and to develop minimally invasive intracardiac procedures. The aim was to create a 3D computer model simulating the in vivo anatomy of the adult equine heart. ANIMALS Ten horses and five ponies. MATERIALS AND METHODS Ten horses, euthanized for non-cardiovascular reasons, were used for in situ cardiac casting with polyurethane foam and subsequent computed tomography (CT) of the excised heart. In five anaesthetized ponies, a contrast-enhanced electrocardiogram-gated CT protocol was optimized to image the entire heart. Dedicated image processing software was used to create 3D models of all CT scans derived from both methods. Resulting models were compared regarding relative proportions, detail and ease of segmentation. RESULTS The casting protocol produced high detail, but compliant structures such as the pulmonary trunk were disproportionally expanded by the foam. Optimization of the contrast-enhanced CT protocol, especially adding a delayed phase for visualization of the cardiac veins, resulted in sufficiently detailed CT images to create an anatomically correct 3D model of the pony heart. Rescaling was needed to obtain a horse-sized model. CONCLUSIONS Three-dimensional computer models based on contrast-enhanced CT images appeared superior to those based on casted hearts to represent the in vivo situation and are preferred to obtain an anatomically correct heart model useful for education, client communication and research purposes. Scaling was, however, necessary to obtain an approximation of an adult horse heart as cardiac CT imaging is restricted by thoracic size.
Collapse
Affiliation(s)
- I Vernemmen
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
| | - G Van Steenkiste
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - S Hauspie
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - L De Lange
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - E Buschmann
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - S Schauvliege
- Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - W Van den Broeck
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - A Decloedt
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - K Vanderperren
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - G van Loon
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| |
Collapse
|
12
|
Yuan D, Li L, Zhang Y, Qi K, Zhang M, Zhang W, Lyu P, Zhang Y, Gao J, Liu J. Image quality improvement in head and neck CT angiography: Individualized post-trigger delay versus fixed delay. Eur J Radiol 2023; 168:111142. [PMID: 37832195 DOI: 10.1016/j.ejrad.2023.111142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 09/27/2023] [Accepted: 10/05/2023] [Indexed: 10/15/2023]
Abstract
PURPOSE To compare the contrast media opacification of head and neck CT angiography (CTA) between conventional fixed trigger delay and individualized post-trigger delay (PTD). METHODS In this prospective study (April-October 2022), 196 consecutive participants were randomly divided into two groups to perform head and neck CTA in bolus tracking with either an individualized PTD (Group A) or a fixed 4-second PTD (Group B). All CT and contrast media protocol parameters were consistent between the two groups. One reader evaluated objective image quality, while two readers rated subjective image quality. Objective image quality was compared between groups via two-sample t-test, while the subjective ratings were compared with chi-square analysis. RESULTS Participants' clinical information including sex, age, weight, body weight index (BMI), and heart rate were not statistically different between two groups (all p > 0.05). Individualized PTD ranging from 3.5 to 7.9 s (average 5.6 s), which is shorter than fixed delays (p < 0.05). Both readers rated better subjective image quality for the Group A (p < 0.05). The mean vessel enhancement was significantly higher in Group A in all vessels (all p < 0.05). CONCLUSIONS Compared to the fixed post-trigger delay in bolus tracking technique, individualized post-trigger delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality for head and neck CT angiography.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Linfeng Li
- Siemens Healthineers GmbH, Forchheim, Germany
| | - Yicun Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Ke Qi
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Mengyuan Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Weiting Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No.1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China.
| |
Collapse
|
13
|
Hubbard L, Molloi S. Low-dose quantitative CT myocardial flow measurement using a single volume scan: phantom and animal validation. J Med Imaging (Bellingham) 2023; 10:056002. [PMID: 37915404 PMCID: PMC10617548 DOI: 10.1117/1.jmi.10.5.056002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 10/11/2023] [Accepted: 10/16/2023] [Indexed: 11/03/2023] Open
Abstract
Purpose To validate a low-dose, single-volume quantitative CT myocardial flow technique in a cardiovascular flow phantom and a swine animal model of coronary artery disease. Approach A cardiovascular flow phantom was imaged dynamically over different flow rates (0.97 to 2.45 mL / min / g ) using 15 mL of contrast per injection. Six swine (37 ± 8 kg ) were also imaged dynamically, with different left anterior descending coronary artery balloon stenoses assessed under intracoronary adenosine stress, using 1 mL / kg of contrast per injection. The resulting images were used to simulate dynamic bolus tracking and peak volume scan acquisition. After which, first-pass single-compartment modeling was performed to derive quantitative flow, where the pre-contrast myocardial attenuation was assumed to be spatially uniform. The accuracy of CT flow was then assessed versus ultrasound and microsphere flow in the phantom and animal models, respectively, using regression analysis. Results Single-volume quantitative CT flow measurements in the phantom (Q CT _ PHANTOM ) were related to reference ultrasound flow measurements (Q US ) by Q CT _ PHANTOM = 1.04 Q US - 0.1 (Pearson's r = 0.98 ; RMSE = 0.09 mL / min / g ). In the animal model (Q CT _ ANIMAL ), they were related to reference microsphere flow measurements (Q MICRO ) by Q CT _ ANIMAL = 1.00 Q MICRO - 0.05 (Pearson's r = 0.96 ; RMSE = 0.48 mL / min / g ). The effective dose per CT measurement was 1.21 mSv. Conclusions The single-volume quantitative CT flow technique only requires bolus tracking data, spatially uniform pre-contrast myocardial attenuation, and a single volume scan acquired near the peak aortic enhancement for accurate, low-dose, myocardial flow measurement (in mL/min/g) under rest and adenosine stress conditions.
Collapse
Affiliation(s)
- Logan Hubbard
- University of California, Irvine, Department of Radiological Sciences, Irvine, California, United States
| | - Sabee Molloi
- University of California, Irvine, Department of Radiological Sciences, Irvine, California, United States
| |
Collapse
|
14
|
Escher F, Fink N, Maurus S, Dinkel J, Ricke J, Hausleiter J, Curta A. Optimization of Preprocedural Full-cycle Computed Tomography in Patients Referred for Transcatheter Tricuspid Valve Repair: Test Bolus Versus Bolus Tracking. J Thorac Imaging 2023; 38:174-178. [PMID: 36374199 DOI: 10.1097/rti.0000000000000682] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE/OBJECTIVES Advancements in transcatheter mitral and tricuspid valve repair have resulted in growing demands in preprocedural computed tomography (CT) imaging. Due to the introduction of multidetector CT (MDCT), shorter acquisition times as well as high rates of heart failure and arrhythmias in this specific patient population, optimal synchronization between the passage of contrast agent and data acquisition is mandatory. There is no consensus on which acquisition technique should be used in this patient population. We aimed to optimize our preprocedural CT protocol comparing bolus tracking (BT) and test bolus (TB) techniques. MATERIALS AND METHODS We performed a retrospective analysis on 151 patients referred for full-cycle MDCT evaluation for transcatheter tricuspid valve repair comparing BT with TB (BT n=75 TB n=75). Contrast-to-noise ratios (CNR) were obtained. Demographic data, laboratory, electrocardiographic, and transthoracic echocardiography/transoesophageal echocardiography parameters were collected from electronic health records. Also, the volume of contrast agent and saline chaser and radiation dose length product and milliampere seconds were collected. RESULTS BT and TB resulted in comparable CNR (BT: 0.47 [0.34 to 0.98]; TB: 0.51 [0.41 to 1.40]; P =0.1). BT was associated with a shorter scan duration (BT: 8.3 min [4.1 to 24.4]; TB: 13.9 min [6.2 to 41.4]; P <0.001), less radiation in terms of dose length product (BT: 1186±585; TB: 1383±679, P =0.04), and lower total volume administration (BT: 101 mL [63 to 16]; TB: 114 mL [71 to 154]; P <0.001). In patients with severely impaired ejection fraction (left ventricular ejection fraction [LVEF] ≤35%; n=65 [TB n=31; BT n=34]) using the TB technique yielded significantly better image quality in terms of CNR (TB=0.57 [0.41 to 1.07); BT=0.41 [0.34 to 0.65]; P =0.02). CONCLUSION In patients with impaired LVEF (LVEF≤35%), the TB technique yielded significantly superior image quality and may be the preferred approach in this specific patient population. BT showed advantages in terms of shorter duration, less radiation, and lower contrast agent volume.
Collapse
Affiliation(s)
| | | | | | | | | | - Jörg Hausleiter
- Cardiology, University Hospital, LMU Munich, Munich, Germany
| | | |
Collapse
|
15
|
Yuan D, Wang Y, Lin S, Gutjahr R, Lyu P, Zhang Y, Gao J, Liu J. Patient-specific post-trigger delay in coronary CT angiography: A prospective study comparing with fixed delay. Eur J Radiol 2023; 163:110813. [PMID: 37043884 DOI: 10.1016/j.ejrad.2023.110813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 03/31/2023] [Accepted: 04/03/2023] [Indexed: 04/14/2023]
Abstract
OBJECTIVES To validate the peak enhancement timing of a patient-specific post-trigger delay (PTD) in Coronary CT angiography (CCTA) and compare its image quality against a fixed PTD. METHODS In this prospective study, 204 consecutive participants were randomly divided into two groups to perform CCTA in bolus tracking with either a fixed 5-second PTD (Group A) or a patient-specific PTD (Group B). Test bolus was also performed in Group B to determine the reference peak enhancement timing. One reader evaluated objective image quality, while two readers rated subjective image quality. The predicted PTD was validated through correlation and agreement analysis with the reference measurement. Objective image quality was compared between groups via two-sample t-test and linear regression, while the subjective ratings were compared with chi-square analysis. RESULTS The two groups each had 102 participants with comparable characteristics (52.9 ± 11.3 versus 52.1 ± 11.3 years of age, and 53 versus 52 males). The scan timing from patient-specific PTD demonstrated strong correlation (R = 0.77) and consistency (ICC = 0.618) with the reference peak timing. Both readers rated better subjective image quality for the Group B (p < 0.001). The mean vessel enhancement was significantly higher in Group B in all coronary vessels (all p < 0.05). After adjusting for the participant variation, the patient-specific PTD strategy was associated with an average of 33.5 HU higher enhancement compared to the fixed PTD. CONCLUSIONS Patient-specific delay could achieve reliable scan timing, optimize vessel opacification and obtain better image quality in CCTA.
Collapse
Affiliation(s)
- Dian Yuan
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yiran Wang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Shushen Lin
- Siemens Healthineers GmbH, Forchheim, Germany
| | | | - Peijie Lyu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Yonggao Zhang
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jianbo Gao
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China
| | - Jie Liu
- The Department of Radiology, The First Affiliated Hospital of Zhengzhou University, No. 1, Eastern Jianshe Road, Zhengzhou 450052, Henan Province, China.
| |
Collapse
|
16
|
Boyer J, Bartoli A, Deharo P, Vaillier A, Ferrara J, Barral PA, Jaussaud N, Morera P, Porto A, Collart F, Jacquier A, Cuisset T. Feasibility of Non-Invasive Coronary Artery Disease Screening with Coronary CT Angiography before Transcatheter Aortic Valve Implantation. J Clin Med 2023; 12:2285. [PMID: 36983286 PMCID: PMC10051299 DOI: 10.3390/jcm12062285] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 03/03/2023] [Accepted: 03/11/2023] [Indexed: 03/17/2023] Open
Abstract
Coronary artery disease (CAD) screening is usually performed before transcatheter aortic valve implantation (TAVI) by invasive coronary angiography (ICA). Computed coronary tomography angiography (CCTA) has shown good diagnostic performance for CAD screening in patients with a low probability of CAD and is systematically performed before TAVI. CCTA could be an efficient alternative to ICA for CAD screening before TAVI. We sought to investigate the diagnostic performance of CCTA in a population of unselected patients without known CAD who were candidates for TAVI. All consecutive patients referred to our center for TAVI without known CAD were enrolled. All patients underwent CCTA and ICA, which were considered the gold standard. A statistical analysis of the diagnostic performance per patient and per artery was performed. 307 consecutive patients were enrolled. CCTA was non-analyzable in 25 patients (8.9%). In the per-patient analysis, CCTA had a sensitivity of 89.6%, a specificity of 90.2%, a positive predictive value of 65.15%, and a negative predictive value of 97.7%. Only five patients were classified as false negatives on the CCTA. Despite some limitations of the study, CCTA seems reliable for CAD screening in patients without known CAD who are candidates for TAVI. By using CCTA, ICA could be avoided in patients with a CAD-RADS score ≤ 2, which represents 74.8% of patients.
Collapse
Affiliation(s)
- Jérémy Boyer
- Département de Cardiologie, CHU Timone, 13005 Marseille, France
| | - Axel Bartoli
- Department of Radiology, CHU Timone, AP-HM, 264, Rue Saint-Pierre, 13005 Marseille, France
- CRMBM-UMR CNRS 7339, Aix-Marseille Université, 27, Boulevard Jean Moulin, CEDEX 05, 13385 Marseille, France
| | - Pierre Deharo
- Département de Cardiologie, CHU Timone, 13005 Marseille, France
- Aix-Marseille Université, Inserm, Inra, C2VN, 13005 Marseille, France
- Faculté de Médecine, Aix-Marseille Université, 13005 Marseille, France
| | | | - Jérôme Ferrara
- Département de Cardiologie, CHU Timone, 13005 Marseille, France
| | - Pierre-Antoine Barral
- Department of Radiology, CHU Timone, AP-HM, 264, Rue Saint-Pierre, 13005 Marseille, France
- CRMBM-UMR CNRS 7339, Aix-Marseille Université, 27, Boulevard Jean Moulin, CEDEX 05, 13385 Marseille, France
| | - Nicolas Jaussaud
- Service de Chirurgie Cardiaque, CHU Timone, 13005 Marseille, France
| | - Pierre Morera
- Service de Chirurgie Cardiaque, CHU Timone, 13005 Marseille, France
| | - Alizée Porto
- Service de Chirurgie Cardiaque, CHU Timone, 13005 Marseille, France
| | - Frédéric Collart
- Faculté de Médecine, Aix-Marseille Université, 13005 Marseille, France
- Service de Chirurgie Cardiaque, CHU Timone, 13005 Marseille, France
| | - Alexis Jacquier
- Department of Radiology, CHU Timone, AP-HM, 264, Rue Saint-Pierre, 13005 Marseille, France
- CRMBM-UMR CNRS 7339, Aix-Marseille Université, 27, Boulevard Jean Moulin, CEDEX 05, 13385 Marseille, France
| | - Thomas Cuisset
- Département de Cardiologie, CHU Timone, 13005 Marseille, France
- Aix-Marseille Université, Inserm, Inra, C2VN, 13005 Marseille, France
- Faculté de Médecine, Aix-Marseille Université, 13005 Marseille, France
| |
Collapse
|
17
|
Kauw F, Velthuis BK, Takx RAP, Guglielmo M, Cramer MJ, van Ommen F, Bos A, Bennink E, Kappelle LJ, de Jong HWAM, Dankbaar JW. Detection of Cardioembolic Sources With Nongated Cardiac Computed Tomography Angiography in Acute Stroke: Results From the ENCLOSE Study. Stroke 2023; 54:821-830. [PMID: 36779342 PMCID: PMC9951793 DOI: 10.1161/strokeaha.122.041018] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
BACKGROUND Identifying cardioembolic sources in patients with acute ischemic stroke is important for the choice of secondary prevention strategies. We prospectively investigated the yield of admission (spectral) nongated cardiac computed tomography angiography (CTA) to detect cardioembolic sources in stroke. METHODS Participants of the ENCLOSE study (Improved Prediction of Recurrent Stroke and Detection of Small Volume Stroke) with transient ischemic attack or acute ischemic stroke with assessable nongated head-to-heart CTA at the University Medical Center Utrecht were included between June 2017 and March 2022. The presence of cardiac thrombus on cardiac CTA was based on a Likert scale and dichotomized into certainly or probably absent versus possibly, probably, or certainly present. The diagnostic certainty of cardiac thrombus was evaluated again on spectral computed tomography reconstructions. The likelihood of a cardioembolic source was determined post hoc by an expert panel in patients with cardiac thrombus on CTA. Parametric and nonparametric tests were used to compare the outcome groups. RESULTS Forty four (12%) of 370 included patients had a cardiac thrombus on admission CTA: 35 (9%) in the left atrial appendage and 14 (4%) in the left ventricle. Patients with cardiac thrombus had more severe strokes (median National Institutes of Health Stroke Scale score, 10 versus 4; P=0.006), had higher clot burden (median clot burden score, 9 versus 10; P=0.004), and underwent endovascular treatment more often (43% versus 20%; P<0.001) than patients without cardiac thrombus. Left atrial appendage thrombus was present in 28% and 6% of the patients with and without atrial fibrillation, respectively (P<0.001). The diagnostic certainty for left atrial appendage thrombus was higher for spectral iodine maps compared with the conventional CTA (P<0.001). The presence of cardiac thrombus on CTA increased the likelihood of a cardioembolic source according to the expert panel (P<0.001). CONCLUSIONS Extending the stroke CTA to cover the heart increases the chance of detecting cardiac thrombi and helps to identify cardioembolic sources in the acute stage of ischemic stroke with more certainty. Spectral iodine maps provide additional value for detecting left atrial appendage thrombus. REGISTRATION URL: https://www. CLINICALTRIALS gov; Unique identifier: NCT04019483.
Collapse
Affiliation(s)
- Frans Kauw
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands.,Brain Center, Department of Neurology and Neurosurgery (F.K., L.J.K.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Birgitta K Velthuis
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Richard A P Takx
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Marco Guglielmo
- Department of Cardiology (M.G., M.J.C.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Maarten J Cramer
- Department of Cardiology (M.G., M.J.C.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Fasco van Ommen
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Anneloes Bos
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Edwin Bennink
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - L Jaap Kappelle
- Brain Center, Department of Neurology and Neurosurgery (F.K., L.J.K.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Hugo W A M de Jong
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| | - Jan W Dankbaar
- Department of Radiology (F.K., B.K.V., R.A.P.T., F.v.O., A.B., E.B., H.W.A.M.d.J., J.W.D.), University Medical Center Utrecht, Utrecht University, the Netherlands
| |
Collapse
|
18
|
Maroules CD, Rybicki FJ, Ghoshhajra BB, Batlle JC, Branch K, Chinnaiyan K, Hamilton-Craig C, Hoffmann U, Litt H, Meyersohn N, Shaw LJ, Villines TC, Cury RC. 2022 use of coronary computed tomographic angiography for patients presenting with acute chest pain to the emergency department: An expert consensus document of the Society of cardiovascular computed tomography (SCCT): Endorsed by the American College of Radiology (ACR) and North American Society for cardiovascular Imaging (NASCI). J Cardiovasc Comput Tomogr 2023; 17:146-163. [PMID: 36253281 DOI: 10.1016/j.jcct.2022.09.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 09/12/2022] [Accepted: 09/13/2022] [Indexed: 11/22/2022]
Abstract
Coronary computed tomography angiography (CTA) improves the quality of care for patients presenting with acute chest pain (ACP) to the emergency department (ED), particularly in patients with low to intermediate likelihood of acute coronary syndrome (ACS). The Society of Cardiovascular Computed Tomography Guidelines Committee was formed to develop recommendations for acquiring, interpreting, and reporting of coronary CTA to ensure appropriate, safe, and efficient use of this modality. Because of the increasing use of coronary CTA testing for the evaluation of ACP patients, the Committee has been charged with the development of the present document to assist physicians and technologists. These recommendations were produced as an educational tool for practitioners evaluating acute chest pain patients in the ED, in the interest of developing systematic standards of practice for coronary CTA based on the best available data or broad expert consensus. Due to the highly variable nature of medical care, approaches to patient selection, preparation, protocol selection, interpretation or reporting that differs from these guidelines may represent an appropriate variation based on a legitimate assessment of an individual patient's needs.
Collapse
Affiliation(s)
| | - Frank J Rybicki
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Brian B Ghoshhajra
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Juan C Batlle
- Department of Radiology, Baptist Cardiac and Vascular Institute, Miami, FL, USA
| | - Kelley Branch
- Department of Cardiology, University of Washington School of Medicine, Seattle, WA, USA
| | | | | | - Udo Hoffmann
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | - Harold Litt
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Nandini Meyersohn
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| | | | - Todd C Villines
- Department of Cardiology, University of Virginia School of Medicine, Charlottesville, VA, USA
| | - Ricardo C Cury
- Department of Radiology, Baptist Cardiac and Vascular Institute, Miami, FL, USA
| |
Collapse
|
19
|
Counseller Q, Aboelkassem Y. Recent technologies in cardiac imaging. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 4:984492. [PMID: 36704232 PMCID: PMC9872125 DOI: 10.3389/fmedt.2022.984492] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 11/30/2022] [Indexed: 01/11/2023] Open
Abstract
Cardiac imaging allows physicians to view the structure and function of the heart to detect various heart abnormalities, ranging from inefficiencies in contraction, regulation of volumetric input and output of blood, deficits in valve function and structure, accumulation of plaque in arteries, and more. Commonly used cardiovascular imaging techniques include x-ray, computed tomography (CT), magnetic resonance imaging (MRI), echocardiogram, and positron emission tomography (PET)/single-photon emission computed tomography (SPECT). More recently, even more tools are at our disposal for investigating the heart's physiology, performance, structure, and function due to technological advancements. This review study summarizes cardiac imaging techniques with a particular interest in MRI and CT, noting each tool's origin, benefits, downfalls, clinical application, and advancement of cardiac imaging in the near future.
Collapse
Affiliation(s)
- Quinn Counseller
- College of Health Sciences, University of Michigan, Flint, MI, United States
| | - Yasser Aboelkassem
- College of Innovation and Technology, University of Michigan, Flint, MI, United States
- Michigan Institute for Data Science, University of Michigan, Ann Arbor, MI, United States
| |
Collapse
|
20
|
Van Gompel G, Delombaerde L, Zanca F, Tanaka K, Belsack D, de Mey J, Buls N. A patient- and acquisition-tailored injection approach for improving consistency of CT enhancement towards a target CT value in coronary CT angiography. J Appl Clin Med Phys 2022; 24:e13867. [PMID: 36537145 PMCID: PMC9860000 DOI: 10.1002/acm2.13867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 11/24/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Unoptimized coronary CT angiography (CTA) exams typically result in a highly variable arterial enhancement (HUa ) across patients. This study aimed at harmonizing arterial enhancement by implementing a patient-, contrast- and kV-tailored injection protocol. METHODS First, the optimal body size metric to predict HUa was identified by retrospectively analysing images of 76 patients, acquired with 70 ml contrast media (G1). Second, using phantom experiments, correction factors for the effect of kV and contrast concentration on HUa were determined. Third, a model was developed, prescribing the optimal contrast dose to be injected to obtain a diagnostically appropriate arterial target enhancement HUtarget . The model was then validated on 278 prospectively collected patients, in two groups with two different HUtarget : 525 HU (207 patients, G2A) and 425 HU (71 patients, G2B). The HUa histograms were compared among groups and to the target enhancement through their mean and standard deviation (SD) at 100 kVp reference level. Also, signal-to-noise ratio was obtained and compared among the groups. RESULTS Fat free mass (FFM) showed the highest correlation with HUa (r = 0.69). KVp correction factors ranged from 0.65 at 70 kVp to 1.22 at 140 kVp. The obtained model reduced the group heterogeneity (SD) from 101HU for reference G1 to 75HU (p < 0.001) for G2A and 68HU (p < 0.001) for G2B. The mean HUa of 506HU in G2A was slightly below HUtarget = 525HU (p = 0.01) whereas in G2B, the mean HUa of 414HU was not significantly different from HUtarget = 425HU (p = 0.54). The total iodine dose was lowered from 19.5 g-I to 17.6 g-I and 14.2 g-I from G1 to G2A and G2B, on average. CONCLUSION A contrast injection model, based on patient's fat free mass and accounting for the contrast agent concentration and the planned CT-scan tube voltage, harmonized arterial enhancement among patients towards a predefined target enhancement in coronary CTA scanning, without affecting the bolus timing.
Collapse
Affiliation(s)
- Gert Van Gompel
- Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of RadiologyBrusselsBelgium
| | | | | | - Kaoru Tanaka
- Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of RadiologyBrusselsBelgium
| | - Dries Belsack
- Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of RadiologyBrusselsBelgium
| | - Johan de Mey
- Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of RadiologyBrusselsBelgium
| | - Nico Buls
- Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Department of RadiologyBrusselsBelgium
| |
Collapse
|
21
|
Dynamic CT myocardial perfusion without image registration. Sci Rep 2022; 12:12608. [PMID: 35871187 PMCID: PMC9308794 DOI: 10.1038/s41598-022-16573-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 07/12/2022] [Indexed: 11/26/2022] Open
Abstract
The aim of this study was to validate a motion-immune (MI) solution to dynamic CT myocardial perfusion measurement, in the presence of motion without image registration. The MI perfusion technique was retrospectively validated in six swine (37.3 ± 7.5 kg) with a motion-susceptible (MS) perfusion technique performed for comparison. In each swine, varying severities of stenoses were generated in the left anterior descending (LAD) coronary artery using a balloon under intracoronary adenosine stress, followed by contrast-enhanced imaging with 20 consecutive volume scans per stenosis. Two volume scans were then systematically selected from each acquisition for both MI and MS perfusion measurement, where the resulting LAD and left circumflex (LCx) measurements were compared to reference microsphere perfusion measurements using regression and diagnostic performance analysis. The MI (PMI) and microsphere (PMICRO) perfusion measurements were related through regression by PMI = 0.98 PMICRO + 0.03 (r = 0.97), while the MS (PMS) and microsphere (PMICRO) perfusion measurements were related by PMS = 0.62 PMICRO + 0.15 (r = 0.89). The accuracy of the MI and MS techniques in detecting functionally significant stenosis was 93% and 84%, respectively. The motion-immune (MI) perfusion technique provides accurate myocardial perfusion measurement in the presence of motion without image registration.
Collapse
|
22
|
Velangi PS, Agdamag AC, Nijjar PS, Pogatchnik B, Nijjar PS. Update on CT Imaging of Left Ventricular Assist Devices and Associated Complications. CURRENT CARDIOVASCULAR IMAGING REPORTS 2022. [DOI: 10.1007/s12410-022-09570-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
23
|
Soschynski M, Hagar MT, Taron J, Krauss T, Ruile P, Hein M, Nührenberg T, Russe MF, Bamberg F, Schlett CL. Update for the Performance of CT Coronary Angiography. ROFO-FORTSCHR RONTG 2022; 194:613-624. [PMID: 35231938 DOI: 10.1055/a-1747-3554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Coronary CT angiography (cCTA) is a class 1 recommendation in the current guidelines by the European Society of Cardiology (ESC) for excluding significant coronary artery stenosis. To achieve optimal image quality at a low radiation dose, the imaging physician may choose different acquisition modes. Therefore, the consensus guidelines by the Society of Cardiovascular Computed Tomography (SCCT) provide helpful guidance for this procedure. METHOD The article provides practical recommendations for the application and acquisition of cCTA based on the current literature and our own experience. RESULTS AND CONCLUSION According to current ESC guidelines, cCTA is recommended in symptomatic patients with a low or intermediate clinical likelihood for coronary artery disease. We recommend premedication with beta blockers and nitrates prior to CT acquisition under certain conditions even with the latest CT scanner generations. The most current CT scanners offer three possible scan modes for cCTA acquisition. Heart rate is the main factor for selecting the scan mode. Other factors may be coronary calcifications and body mass index (BMI). KEY POINTS · CCTA is a valid method to exclude coronary artery disease in patients with a low to intermediate clinical likelihood.. · Even with the latest generation CT scanners, premedication with beta blockers and nitrates can improve image quality at low radiation exposure.. · Current CT scanners usually provide retrospective ECG gating and prospective ECG triggering. Dual-source scanners additionally provide a "high pitch" scan mode to scan the whole heart during one heartbeat, which may also be achieved using single-source scanners with broad detectors in some cases.. · Besides the available scanner technology, the choice of scan mode primarily depends on heart rate and heart rate variability (e. g., arrhythmia).. CITATION FORMAT · Soschynski M, Hagar MT, Taron J et al. Update for the Performance of CT Coronary Angiography. Fortschr Röntgenstr 2022; DOI: 10.1055/a-1747-3554.
Collapse
Affiliation(s)
- Martin Soschynski
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Muhammad Taha Hagar
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Jana Taron
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany.,Cardiac MR PET CT Program, Massachusetts General-Hospital, Harvard Medical School, Boston, United States
| | - Tobias Krauss
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Philipp Ruile
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Manuel Hein
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Thomas Nührenberg
- Department of Cardiology & Angiology II, University Heart Center Freiburg-Bad Krozingen, Germany
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Christopher L Schlett
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| |
Collapse
|
24
|
Wang Y, Chen Y, Liu P, Lv W, Wu J, Wei M, Shi D, Wu X, Liu W, Tao X, Hu H, Ma X, Yang X, Xue H, Jin Z. Clinical effectiveness of contrast medium injection protocols for 80-kV coronary and craniocervical CT angiography-a prospective multicenter observational study. Eur Radiol 2022; 32:3808-3818. [PMID: 35103828 DOI: 10.1007/s00330-021-08505-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 10/22/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVE Decreasing X-ray tube voltage is an effective way to reduce radiation and contrast dose, especially in non-obese patients. The current study focuses on CTA in non-obese patients to evaluate image quality and feasibility of 80-kV acquisition protocols with varying iodine delivery rates (IDR) and contrast concentrations in routine clinical practice. METHODS A prospective observational study in patients ≥ 18 years and ≤ 90 kg referred for coronary or craniocervical CTA at 10 centers in China (ClinicalTrials.gov: NCT02840903). Patients were divided into four groups: a standard 100-kV protocol (370 mgI/ml, IDR 1.48 gI/s), and three 80-kV protocols (370 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 1.2 gI/s; 300 mgI/ml, IDR 0.96gI/s). The primary outcome was contrast opacification of target vascular segments. Secondary outcomes were image quality (contrast-to-noise ratio, signal-to-noise ratio, visual image quality, and diagnostic confidence assessment), radiation, and iodine dose. RESULTS From July 2016 to July 2017, 1213 patients were enrolled: 614 coronary and 599 craniocervical CTA. The mean contrast opacification was ≥ 300 HU for 80-kV 1.2 gI/s IDR scanned segments; IDR 0.96 gI/s led to lower opacification. Image quality and diagnostic confidence were fair to excellent (≥ 98% of images), despite lower contrast-to-noise ratios and signal-to-noise ratios in 80-kV images. Compared to the standard protocol, 80-kV protocols led to 44-52% radiation dose reductions (p < 0.001) and 19% iodine dose reductions (p < 0.001). CONCLUSION Eighty-kilovolt 1.2 gI/s IDR protocols can be recommended for coronary and craniocervical CTA in non-obese patients, reducing radiation and iodine dose without compromising image quality. KEY POINTS • Using low-voltage scanning CTA protocols, in which tube voltage and iodine delivery rate are reduced proportionally (voltage: 80 kV, IDR: 1.2 gI/s), reduces radiation and contrast dose without compromising image quality in routine clinical practice. • Reducing iodine delivery rate beyond direct proportionality to tube voltage is not beneficial.
Collapse
Affiliation(s)
- Yining Wang
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Yu Chen
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Peijun Liu
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Wan Lv
- The First People's Hospital of Yulin, # 495, JiaoYu Central Road, Yulin, 537000, Guangxi, China
| | - Jianlin Wu
- Affiliated Zhongshan Hospital of Dalian University, # 6, Jiefang Road Zhongshan District, Dalian, 116001, Liaoning, China
| | - Mengqi Wei
- The First Affiliated Hospital of Air Force Medical University, # 15 Changle West Road, Xian, 710032, Shanxi, China
| | - Dapeng Shi
- Henan Provincial People's Hospital, # 7, Weiwu Road, Zhengzhou, 450000, Henan, China
| | - Xianheng Wu
- The Second People's Hospital of Shantou, # 28, Waimalu Road, Shantou, 515031, Guangdong, China
| | - Wenya Liu
- The First Affiliated Hospital of Xinjiang Medical University, # 137, Liyushan South Road, Urumqi, 830054, Xinjiang, China
| | - Xiaofeng Tao
- Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, # 639, Zaoju Road, Shanghai, 200011, China
| | - Hongjie Hu
- Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 Qinchun East Road, Hangzhou, 310016, Zhejiang, China
| | - Xiangxing Ma
- Qilu Hospital of Shandong University (Qingdao), North District, # 758, Hefei Road, Qingdao, 266035, Shandong, China
| | - Xiaozheng Yang
- Medical Affairs, Bayer Healthcare Co. Ltd, Dongshanhuan Central Road, Beijing, 100010, China
| | - Huadan Xue
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China
| | - Zhengyu Jin
- Peking Union Medical College Hospital, Shuaifuyan Wangfujing District, Beijing, 100730, China.
| |
Collapse
|
25
|
Effect of Body Mass Index in Coronary CT Angiography Performed on a 256-Slice Multi-Detector CT Scanner. Diagnostics (Basel) 2022; 12:diagnostics12020319. [PMID: 35204410 PMCID: PMC8871507 DOI: 10.3390/diagnostics12020319] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 01/18/2022] [Accepted: 01/24/2022] [Indexed: 12/21/2022] Open
Abstract
We aimed to investigate the effect of a patient’s body mass index (BMI) on radiation dose and image quality in prospectively ECG-triggered coronary CT angiography (CCTA) performed on a 256-slice multi-detector CT scanner. In total, 87 consecutive patients receiving CCTA examinations acquired with tube current modulation (TCM) and iterative reconstruction (IR) were enrolled in this study. The dose report recorded from the CT scanner console was used to derive the effective dose for patients. Subjective image quality scoring and objective noise measurements were conducted to quantify the impact of BMI on the image quality of CCTA. Because of the TCM technique, we expected tube current and radiation dose to increase as BMI increased. However, using TCM did not always guarantee sufficient radiation exposure to achieve consistent image quality for overweight or obese patients since the maximum X-ray tube output in milliamperes and kilovoltage peak was reached. The impact of photon starvation noise on image quality was not significant until BMI ≥ 27 kg/m2; this result could be due to IR’s noise reduction capability. Our results also suggest that using TCM with a noise index of 25 HU can reduce radiation dose without compromising image quality compared to images obtained based on the manufacturer’s default settings.
Collapse
|
26
|
Liang CR, Ong CC, Chai P, Teo LLS. Comparison of radiation dose, contrast enhancement and image quality of prospective ECG-Gated CT coronary angiography: Single versus dual source CT. Radiography (Lond) 2021; 27:831-839. [PMID: 33581989 DOI: 10.1016/j.radi.2021.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 01/09/2021] [Accepted: 01/13/2021] [Indexed: 10/22/2022]
Abstract
INTRODUCTION The updated National Institute of Clinical Excellence (NICE) guidelines of 2017 state that new generation cardiac CT scanners (Aquilion ONE, Brilliance iCT, Discovery CT750 HD and Somatom Definition Flash) are recommended as an option for first-line imaging of the coronary arteries in people with suspected stable coronary artery disease (with an estimated likelihood of coronary artery disease of 10-29%) in whom imaging with earlier generation CT scanners is difficult. New generation cardiac CT scanners are also recommended as an option for first-line evaluation of disease progression, to establish need for revascularisation in people with known coronary artery disease in whom imaging with earlier generation CT scanners is difficult. CT scanning might not be necessary in situations in which immediate revascularisation is being considered. The European Society of Cardiology 2019 clinical practice guidelines recommend non-invasive functional imaging for myocardial ischaemia or coronary CT angiography (CTA) as the initial test to diagnose CAD in symptomatic patients in whom obstructive CAD cannot be excluded by clinical assessment alone. Given increased computed tomography coronary angiogram (CTCA) utilisation, radiation dose, contrast enhancement and image quality of prospective ECG-gated CTCA between 256-slice single-source and 192x2-slice dual-source CT scanners were retrospectively evaluated. METHODS Prospectively gated CTCA data from 63 patients on a 256-slice CT (group A) and 71 patients on a 192x2-slice dual source CT (group B) from January to December 2016 were retrospectively evaluated respectively. Scanner-reported dose length product values were used with a conversion factor (k = 0.014 mSv/mGy x cm) to estimate effective dose. Contrast enhancement was assessed with mean CT attenuation at selected regions of interest on axial coronary images. Image quality of the coronary arteries was assessed by a 4-point grading score (1 = non-diagnostic, 4 = excellent image quality). RESULTS The radiation doses in group B were significantly lower than group A (3.68 + 2.13 mSv versus 4.81 + 1.56 mSv, p < 0.001). There were no significant differences in contrast enhancement in the left coronary artery, proximal right coronary artery and left ventricular wall for both groups. Vessel image quality scores for group B were higher than group A (right coronary artery (RCA): 3.2 + 0.7 versus 2.4 + 0.7, p < 0.001; left anterior descending (LAD) artery: 3.0 + 0.8 vs 2.5 + 0.6, p < 0.001; left circumflex (LCx) artery: 3.3 + 0.7 vs 2.6 + 0.6, p < 0.001). Coronary artery contour scores for group B were significantly higher than group A (RCA: 3.2 + 0.8 versus 2.3 + 0.7, p < 0.001; LAD: 3.0 + 0.7 versus 2.4 + 0.6, p < 0.001; LCx: 3.3 + 0.6 versus 2.5 + 0.6, p < 0.001). CONCLUSION Prospective ECG-gated CTCA performed on 192x2-slice CT results in better image quality and lower radiation dose than 256-slice CT. There were no significant differences in contrast enhancement in left main coronary artery (LMCA), proximal RCA and left ventricular wall in both groups. IMPLICATIONS FOR PRACTICE In institutions with both 256-slice and 192x2-slice CT scanners, we recommend that CTCAs be preferentially performed using the 192x2-slice CT scanner.
Collapse
Affiliation(s)
- C R Liang
- Department of Diagnostic Imaging, National University Hospital, Singapore
| | - C C Ong
- Department of Diagnostic Imaging, National University Hospital, Singapore
| | - P Chai
- Department of Diagnostic Imaging, National University Hospital, Singapore
| | - L L S Teo
- Department of Diagnostic Imaging, National University Hospital, Singapore.
| |
Collapse
|
27
|
Du H, Shao K, Bao F, Zhang Y, Gao C, Wu W, Zhang C. Automated coronary artery tree segmentation in coronary CTA using a multiobjective clustering and toroidal model-guided tracking method. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 199:105908. [PMID: 33373814 DOI: 10.1016/j.cmpb.2020.105908] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 12/13/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Accurate coronary artery tree segmentation can now be developed to assist radiologists in detecting coronary artery disease. In clinical medicine, the noise, low contrast, and uneven intensity of medical images along with complex shapes and vessel bifurcation structures make coronary artery segmentation challenging. In this work, we propose a multiobjective clustering and toroidal model-guided tracking method that can accurately extract coronary arteries from computed tomography angiography (CTA) imagery. METHODS Utilizing integrated noise reduction, candidate region detection, geometric feature extraction, and coronary artery tracking techniques, a new segmentation framework for 3D coronary artery trees is presented. The candidate regions are extracted using a multiobjective clustering method, and the coronary arteries are tracked by a toroidal model-guided tracking method. RESULTS The qualitative and quantitative results demonstrate the effectiveness of the presented framework, which achieves better performance than the compared segmentation methods in three widely used evaluation indices: the Dice similarity coefficient (DSC), Jaccard index and Recall across the CTA data. The proposed method can accurately identify the coronary artery tree with a mean DSC of 84%, a Jaccard index of 74%, and a Recall of 93%. CONCLUSIONS The proposed segmentation framework effectively segments the coronary tree from the CTA volume, which improves the accuracy of 3D vascular tree segmentation.
Collapse
Affiliation(s)
- Hongwei Du
- School of Mathmatics, Shandong University, Jinan, Shandong 250100, China; Shandong Provincial Key Laboratory of Digital Media Technology, Jinan, Shandong 250014, China
| | - Kai Shao
- Shandong Provincial Key Laboratory of Digital Media Technology, Jinan, Shandong 250014, China; School of Computer Science and Technology, Shandong University of Finance and Economics, Jinan, Shandong 250014, China
| | - Fangxun Bao
- School of Mathmatics, Shandong University, Jinan, Shandong 250100, China.
| | - Yunfeng Zhang
- Shandong Provincial Key Laboratory of Digital Media Technology, Jinan, Shandong 250014, China; School of Computer Science and Technology, Shandong University of Finance and Economics, Jinan, Shandong 250014, China
| | - Chengyong Gao
- School of Physics, Shandong University, Jinan, Shandong 250100, China
| | - Wei Wu
- Department of Cerebrovascular Diseases, Cheeloo College of Medicine, Shandong University, Jinan, Shandong 250012, China
| | - Caiming Zhang
- Shandong Provincial Key Laboratory of Digital Media Technology, Jinan, Shandong 250014, China; School of Computer Science and Technology, Shandong University, Jinan, Shandong 250101, China
| |
Collapse
|
28
|
Feasibility of Low Volume of High-Concentration Iodinated Contrast Medium With 70 kVp Tube Voltage on High-Pitch Dual-Source Computed Tomography Angiography in Children With Congenital Heart Disease. J Comput Assist Tomogr 2021; 45:52-58. [PMID: 32740051 DOI: 10.1097/rct.0000000000001033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The objective of this study was to investigate the feasibility of high-concentration iodinated contrast medium (CM) with 70 kVp tube voltage on high-pitch dual-source computed tomography (DSCT) in children with congenital heart disease (CHD). METHODS Fifty-eight CHD patients underwent high-pitch DSCT in 2 protocols: 70 kVp tube voltage, 1.0 mL/kg CM volume, 370 mg I/mL concentration (group A); 80 kVp tube voltage, 1.5 mL/kg CM volume, 350 mg I/mL concentration (group B). The diagnostic accuracy, image quality, iodine delivery rate, iodine dose, and radiation dose were compared. RESULTS There was no significant difference in the diagnostic accuracy (P > 0.05), image quality (P > 0.05) and iodine delivery rate (P > 0.05) between the 2 groups. The iodine dose (P < 0.05) and radiation dose (P < 0.05) in group A were significantly lower than those in group B. CONCLUSIONS Reduction in iodine dose and radiation exposure can be achieved with 70 kVp high-pitch DSCT by administering a smaller volume of high-concentration CM in children with CHD.
Collapse
|
29
|
The Role of Cardiac Computed Tomography in Valve Disease and Valve Intervention Planning. CURRENT TREATMENT OPTIONS IN CARDIOVASCULAR MEDICINE 2021. [DOI: 10.1007/s11936-020-00879-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
30
|
Pediatric Cardiac CT and MRI: Considerations for the General Radiologist. AJR Am J Roentgenol 2020; 215:1464-1473. [PMID: 33084361 DOI: 10.2214/ajr.19.22745] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
31
|
Kim JY, Suh YJ, Han K, Kim YJ, Choi BW. Cardiac CT for Measurement of Right Ventricular Volume and Function in Comparison with Cardiac MRI: A Meta-Analysis. Korean J Radiol 2020; 21:450-461. [PMID: 32193893 PMCID: PMC7082652 DOI: 10.3348/kjr.2019.0499] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 12/16/2019] [Indexed: 11/18/2022] Open
Affiliation(s)
- Jin Young Kim
- Department of Radiology, Dongsan Hospital, Keimyung University College of Medicine, Daegu, Korea
| | - Young Joo Suh
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| | - Kyunghwa Han
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Young Jin Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Byoung Wook Choi
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
32
|
CT Imaging of Left Ventricular Assist Devices and Associated Complications. CURRENT CARDIOVASCULAR IMAGING REPORTS 2020. [DOI: 10.1007/s12410-020-09546-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
33
|
Ibe DO, Rapp JB, Whitehead KK, Otero HJ, Smith CL, Fogel MA, Biko DM. Pearls and Pitfalls in Pediatric Fontan Operation Imaging. Semin Ultrasound CT MR 2020; 41:442-450. [PMID: 32980091 DOI: 10.1053/j.sult.2020.05.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The Fontan operation or the total cavopulmonary connection is a palliative surgery for single ventricle congenital heart disease where the systemic venous return circumvents a pumping chamber and flows directly into the pulmonary circuit. With surgical and medical advances, there has been improvement in life expectancy of these patients, however, it has also resulted in unique complications from the physiology that requires diligent surveillance. A critical component relies on optimal imaging for diagnosis and treatment of these complications. This article describes the normal anatomy of the Fontan circulation, current imaging modalities and techniques, and frequently encountered complications seen when imaging the patients who have undergone Fontan palliation.
Collapse
Affiliation(s)
- Donald O Ibe
- Department of Radiology, Silhouette Diagnostic Consultants, Abuja, Nigeria
| | - Jordan B Rapp
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA; Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA
| | - Kevin K Whitehead
- Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - Hansel J Otero
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - Christopher L Smith
- Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - Mark A Fogel
- Perelman School of Medicine at The University of Pennsylvania, Philadelphia, PA; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA
| | - David M Biko
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA; Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA.
| |
Collapse
|
34
|
Guglielmi V, Planken RN, Mihl C, Niesen S, Staals J, Coutinho JM, Postma AA. Non-gated cardiac CT angiography for detection of cardio-aortic sources of embolism in the acute phase of ischaemic stroke. J Neurol Neurosurg Psychiatry 2020; 91:442-443. [PMID: 31974129 DOI: 10.1136/jnnp-2019-321923] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 12/10/2019] [Accepted: 12/24/2019] [Indexed: 11/04/2022]
Affiliation(s)
- Valeria Guglielmi
- Neurology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Robrecht Nils Planken
- Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Casper Mihl
- Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Sandra Niesen
- Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Julie Staals
- Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands.,Neurology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Jonathan M Coutinho
- Neurology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Alida A Postma
- Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands .,School for Mental Health & Neuroscience, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
35
|
|
36
|
Scholtz JE, Hedgire S, Ghoshhajra BB. Technical Aspects, Interpretation, and Body of Evidence for Coronary Computed Tomography Angiography. Radiol Clin North Am 2019; 57:13-23. [DOI: 10.1016/j.rcl.2018.08.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
37
|
Anton-Martin P, Willis BC, Nigro JJ, Budolfson K, Raz D, Jamshidi R. Complete traumatic aortic transection. JOURNAL OF PEDIATRIC SURGERY CASE REPORTS 2018. [DOI: 10.1016/j.epsc.2018.08.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
38
|
Optimizing Cardiac CTA Acquisition in Congenital Heart Disease. CURRENT RADIOLOGY REPORTS 2018. [DOI: 10.1007/s40134-018-0294-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
39
|
Rajiah P, Abbara S. Advances in cardiac CT. Cardiovasc Diagn Ther 2017; 7:429-431. [PMID: 29255686 DOI: 10.21037/cdt.2017.08.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Prabhakar Rajiah
- Associate Professor of Radiology, Associate Director, Cardiac CT and MRI, UT Southwestern Medical Center, Dallas, Texas 75390, USA.
| | - Suhny Abbara
- Professor, Department of Radiology, Chief Cardiothoracic Imaging, UT Southwestern Medical Center, Dallas, Texas 75390, USA.
| |
Collapse
|