1
|
Maqsood HA, Jawed HA, Kumar H, Bansal R, Shahid B, Nazir A, Rustam Z, Aized MT, Scemesky EA, Lepidi S, Bertoglio L, D'Oria M. Advanced Imaging Techniques for Complex Endovascular Aortic Repair: Pre-Operative, Intra-Operative and Post-Operative Advancements. Ann Vasc Surg 2024:S0890-5096(24)00288-7. [PMID: 38942370 DOI: 10.1016/j.avsg.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 06/02/2024] [Accepted: 06/07/2024] [Indexed: 06/30/2024]
Abstract
OBJECTIVES Endovascular aortic repair requires extensive preoperative, intraoperative, and postoperative imaging for planning, surveillance, and detection of endo-leaks. There have been many advancements in imaging modalities to achieve this purpose. This review discussed different imaging modalities used at different stages of treatment of complex endovascular aortic repair. METHODS We conducted a literature review of all the imaging modalities utilized in endovascular aortic repair by searching various databases. RESULTS Pre-operative techniques include analysis of images obtained via modified central line using analysis software and intravascular ultrasound. Fusion imaging, CO2 angiography, intravascular ultrasound, and Fiber Optic RealShape technology have been crucial in obtaining real-time imaging for the detection of endo-leaks during operative procedures. Conventional imaging modalities like CT Angiography and MR Angiography are still employed for post-operative surveillance along with computational fluid dynamics and contrast-enhanced ultrasound. The advancements in artificial intelligence have been the breakthrough in developing robust imaging applications. CONCLUSIONS This review explains the advantages, disadvantages, and side-effect profile of the abovementioned imaging modalities.
Collapse
Affiliation(s)
| | | | | | - Radha Bansal
- Government Medical College and Hospital, Chandigarh, India
| | | | | | - Zainab Rustam
- Wilmer Eye Institute, John Hopkins Medicine, Baltimore, MD, USA
| | - Majid Toseef Aized
- Ascension St. Mary's Hospital, Vascular Health clinics, Saginaw, Michigan, USA
| | | | - Sandro Lepidi
- Division of Vascular and Endovascular Surgery, University Hospital of Trieste ASUGI, Italy
| | - Luca Bertoglio
- Department of Vascular Surgery, Brescia University School of Medicine, Italy
| | - Mario D'Oria
- Division of Vascular and Endovascular Surgery, University Hospital of Trieste ASUGI, Italy
| |
Collapse
|
2
|
Khdhir M, Ghosn Y, Jabbour Y, Abbas N, Tarcha Z, Kayali M, Khouzami R, Natout M, Muallem N. Does delayed phase imaging in CT angiography provide additional information in patients with suspected active bleeding? Emerg Radiol 2024:10.1007/s10140-024-02239-9. [PMID: 38760647 DOI: 10.1007/s10140-024-02239-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 05/01/2024] [Indexed: 05/19/2024]
Abstract
PURPOSE We hypothesize that delayed phase imaging does not provide additional diagnostic information in patients who undergo multi-phasic CTA for suspected active bleeding. METHODS Data on patients who underwent multiphasic CTA (pre-contrast, arterial, porto-venous, and delayed phases) for suspected acute bleed were retrospectively collected between January 2019 and November 2021. CTA images were reviewed by a general radiologist, an interventional radiologist, and a body imaging radiologist independently. Each reader evaluated if delayed phase images provided additional information that would change the final impression of the CTA report. Additional information regarding bleeding location, time needed for delayed image acquisition, and radiation exposure were also obtained. RESULTS A total of 104 patients with CTAs were analyzed with an average age of 58 years ± 22. Studies rated with absent additional findings on delayed images were 102 (98.1%) by the interventional radiologist, 101 (97.1%) by the body imaging radiologist, and 100 (96.1%) by the general radiologist with percent agreement of 96.15% (kappa 0.54, p < 0.001). All the findings were characterized as unlikely to be clinically significant. Mean time added to complete a delayed phase images was 3.61 ± 3.4 min. The average CT dose length product (DLP) for the total exam was 3621.78 ± 2129.57 mGy.cm with delayed acquisition adding a mean DLP of 847.75 ± 508.8 mGy.cm. CONCLUSION Delayed phase imaging does not provide significant additional diagnostic information in evaluating patients with suspected active bleeding but is associated with increased examination time and radiation exposure.
Collapse
Affiliation(s)
- Mihran Khdhir
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, USA
| | - Youssef Ghosn
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O. Box 11-0236, Bierut, 1107 2020, Lebanon
| | - Yara Jabbour
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O. Box 11-0236, Bierut, 1107 2020, Lebanon
| | - Nada Abbas
- American University of Beirut, Bierut, Lebanon
| | - Ziad Tarcha
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, USA
| | - Mohamad Kayali
- Department of Radiology, University of Iowa Hospital and Clinics, Lowa, USA
| | - Riad Khouzami
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O. Box 11-0236, Bierut, 1107 2020, Lebanon
| | - Mustafa Natout
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O. Box 11-0236, Bierut, 1107 2020, Lebanon
| | - Nadim Muallem
- Department of Diagnostic Radiology, American University of Beirut, Riad El-Solh, P.O. Box 11-0236, Bierut, 1107 2020, Lebanon.
| |
Collapse
|
3
|
Contrella BN, Khaja MS, Majdalany BS, Kim CY, Kalva SP, Beck AW, Browne WF, Clough RE, Ferencik M, Fleischman F, Gunn AJ, Hickey SM, Kandathil A, Kim KM, Monroe EJ, Ochoa Chaar CI, Scheidt MJ, Smolock AR, Steenburg SD, Waite K, Pinchot JW, Steigner ML. ACR Appropriateness Criteria® Thoracoabdominal Aortic Aneurysm or Dissection: Treatment Planning and Follow-Up. J Am Coll Radiol 2023; 20:S265-S284. [PMID: 37236748 DOI: 10.1016/j.jacr.2023.02.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 02/27/2023] [Indexed: 05/28/2023]
Abstract
As the incidence of thoracoabdominal aortic pathology (aneurysm and dissection) rises and the complexity of endovascular and surgical treatment options increases, imaging follow-up of patients remains crucial. Patients with thoracoabdominal aortic pathology without intervention should be monitored carefully for changes in aortic size or morphology that could portend rupture or other complication. Patients who are post endovascular or open surgical aortic repair should undergo follow-up imaging to evaluate for complications, endoleak, or recurrent pathology. Considering the quality of diagnostic data, CT angiography and MR angiography are the preferred imaging modalities for follow-up of thoracoabdominal aortic pathology for most patients. The extent of thoracoabdominal aortic pathology and its potential complications involve multiple regions of the body requiring imaging of the chest, abdomen, and pelvis in most patients. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Collapse
Affiliation(s)
| | | | - Bill S Majdalany
- Panel Chair, University of Vermont Medical Center, Burlington, Vermont
| | - Charles Y Kim
- Panel Chair, Duke University Medical Center, Durham, North Carolina
| | - Sanjeeva P Kalva
- Panel Vice-Chair, Massachusetts General Hospital, Boston, Massachusetts
| | - Adam W Beck
- University of Alabama at Birmingham Medical Center, Birmingham, Alabama; Society for Vascular Surgery
| | | | - Rachel E Clough
- St Thomas' Hospital, King's College, School of Biomedical Engineering and Imaging Science, London, United Kingdom; Society for Cardiovascular Magnetic Resonance
| | - Maros Ferencik
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon; Society of Cardiovascular Computed Tomography
| | - Fernando Fleischman
- Keck School of Medicine of USC, Los Angeles, California; American Association for Thoracic Surgery
| | - Andrew J Gunn
- University of Alabama at Birmingham, Birmingham, Alabama
| | - Sean M Hickey
- David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California; American College of Emergency Physicians
| | - Asha Kandathil
- UT Southwestern Medical Center, Dallas, Texas; Commission on Nuclear Medicine and Molecular Imaging
| | - Karen M Kim
- University of Michigan, Ann Arbor, Michigan; The Society of Thoracic Surgeons
| | | | | | | | - Amanda R Smolock
- Froedtert & The Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Scott D Steenburg
- Indiana University School of Medicine and Indiana University Health, Indianapolis, Indiana; Committee on Emergency Radiology-GSER
| | - Kathleen Waite
- Duke University Medical Center, Durham, North Carolina, Primary care physician
| | - Jason W Pinchot
- Specialty Chair, University of Wisconsin, Madison, Wisconsin
| | | |
Collapse
|
4
|
Punzo B, Ranieri B, Tramontano L, Affinito O, Franzese M, Bossone E, Saba L, Cavaliere C, Cademartiri F. 4D-Flow Cardiovascular Magnetic Resonance Sequence for Aortic Assessment: Multi-Vendor and Multi-Magnetic Field Reproducibility in Healthy Volunteers. J Clin Med 2023; 12:jcm12082960. [PMID: 37109295 PMCID: PMC10141060 DOI: 10.3390/jcm12082960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/03/2023] [Accepted: 04/14/2023] [Indexed: 04/29/2023] Open
Abstract
OBJECTIVES Four-dimensional (4D) flow cardiac magnetic resonance (CMR) represents an emerging technique for non-invasive evaluation of the aortic flow. The aim of this study was to investigate a 4D-flow CMR sequence for the assessment of thoracic aorta comparing different vendors and different magnetic fields of MR scanner in fifteen healthy volunteers. METHODS CMR was performed on three different MRI scanners: one at 1.5 T and two at 3 T. Flow parameters and planar wall shear stress (WSS) were extracted from six transversal planes along the full thoracic aorta by three operators. Inter-vendor comparability as well as scan-rescan, intra- and interobserver reproducibility were examined. RESULTS A high heterogeneity was found in the comparisons for each operator and for each scanner in the six transversal planes analysis (Friedman rank-sum test; p-value ≤ 0.05). Among all, the most reproducible measures were extracted for the sinotubular junction plane and for the flow parameters. CONCLUSIONS Our results suggest that standardized procedures have to be defined to make more comparable and reproducible 4D-flow parameters and mainly, clinical impactfulness. Further studies on sequences development are needed to validate 4D-flow MRI assessment across vendors and magnetic fields also compared to a missing gold standard.
Collapse
Affiliation(s)
- Bruna Punzo
- IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy
| | - Brigida Ranieri
- IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy
| | | | - Ornella Affinito
- IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy
| | - Monica Franzese
- IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy
| | - Eduardo Bossone
- Department of Public Health, "Federico II" University of Naples, 80131 Naples, Italy
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero-Universitaria (A.O.U.) di Cagliari, 09123 Cagliari, Italy
| | - Carlo Cavaliere
- IRCCS SYNLAB SDN, Via Emanuele Gianturco 113, 80143 Naples, Italy
| | | |
Collapse
|
5
|
Rastogi V, Stefens SJM, Houwaart J, Verhagen HJM, de Bruin JL, van der Pluijm I, Essers J. Molecular Imaging of Aortic Aneurysm and Its Translational Power for Clinical Risk Assessment. Front Med (Lausanne) 2022; 9:814123. [PMID: 35492343 PMCID: PMC9051391 DOI: 10.3389/fmed.2022.814123] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/21/2022] [Indexed: 01/03/2023] Open
Abstract
Aortic aneurysms (AAs) are dilations of the aorta, that are often fatal upon rupture. Diagnostic radiological techniques such as ultrasound (US), magnetic resonance imaging (MRI), and computed tomography (CT) are currently used in clinical practice for early diagnosis as well as clinical follow-up for preemptive surgery of AA and prevention of rupture. However, the contemporary imaging-based risk prediction of aneurysm enlargement or life-threatening aneurysm-rupture remains limited as these are restricted to visual parameters which fail to provide a personalized risk assessment. Therefore, new insights into early diagnostic approaches to detect AA and therefore to prevent aneurysm-rupture are crucial. Multiple new techniques are developed to obtain a more accurate understanding of the biological processes and pathological alterations at a (micro)structural and molecular level of aortic degeneration. Advanced anatomical imaging combined with molecular imaging, such as molecular MRI, or positron emission tomography (PET)/CT provides novel diagnostic approaches for in vivo visualization of targeted biomarkers. This will aid in the understanding of aortic aneurysm disease pathogenesis and insight into the pathways involved, and will thus facilitate early diagnostic analysis of aneurysmal disease. In this study, we reviewed these molecular imaging modalities and their association with aneurysm growth and/or rupture risk and their limitations. Furthermore, we outline recent pre-clinical and clinical developments in molecular imaging of AA and provide future perspectives based on the advancements made within the field. Within the vastness of pre-clinical markers that have been studied in mice, molecular imaging targets such as elastin/collagen, albumin, matrix metalloproteinases and immune cells demonstrate promising results regarding rupture risk assessment within the pre-clinical setting. Subsequently, these markers hold potential as a future diagnosticum of clinical AA assessment. However currently, clinical translation of molecular imaging is still at the onset. Future human trials are required to assess the effectivity of potentially viable molecular markers with various imaging modalities for clinical rupture risk assessment.
Collapse
Affiliation(s)
- Vinamr Rastogi
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Sanne J. M. Stefens
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Judith Houwaart
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Hence J. M. Verhagen
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Jorg L. de Bruin
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Ingrid van der Pluijm
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
| | - Jeroen Essers
- Department of Vascular Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, Netherlands
- Department of Radiation Oncology, Erasmus University Medical Center, Rotterdam, Netherlands
- *Correspondence: Jeroen Essers
| |
Collapse
|
6
|
Rabin A, Palacio D, Saqib N, Bar-Yoseph P, Weiss D, Afifi RO. Aortic aneurysms and dissections: Unmet needs from physicians and engineers perspectives. J Biomech 2021; 122:110461. [PMID: 33901933 DOI: 10.1016/j.jbiomech.2021.110461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 03/31/2021] [Indexed: 10/21/2022]
Abstract
The treatment of aortic disease is complex, requiring cardiothoracic and vascular surgeons to make pre-, post- and intraoperative decisions directly influencing patient survival and well-being. Despite tremendous advancement in vascular surgery and endovascular techniques in the last two decades, along with the abundance of research in the field, many unmet needs and unanswered questions remain. Tight collaboration between engineers and physicians is a keystone in translating new tools, techniques, and devices into practice. Here, we have gathered our perspective, as physicians and engineers, in several pressing issues associated with the diagnosis and treatment of aortic aneurysms and dissection, referring to the current knowledge and practice, signifying unmet needs as well as future directions.
Collapse
Affiliation(s)
- Asaf Rabin
- Department of Vascular and Endovascular Surgery Unit, B. Padeh M.C, Poriya, Israel.
| | - Diana Palacio
- Cardiothoracic Imaging Division, Department of Medical Imaging, The University of Arizona Banner Medical Center, Tucson, AZ, USA
| | - Naveed Saqib
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| | - Pinhas Bar-Yoseph
- Faculty of Mechanical Engineering, Technion-Israel Institute of Technology, Haifa, Israel
| | - Dar Weiss
- Department of Biomedical Engineering, Yale university, CT, USA
| | - Rana O Afifi
- Department of Cardiothoracic and Vascular Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston (UTHealth), Houston, TX, USA
| |
Collapse
|
7
|
Rehani MM, Heil J, Baliyan V. Multicentric study of patients receiving 50 or 100 mSv in a single day through CT imaging-frequency determination and imaging protocols involved. Eur Radiol 2021; 31:6612-6620. [PMID: 33683390 DOI: 10.1007/s00330-021-07734-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 12/17/2020] [Accepted: 02/01/2021] [Indexed: 02/06/2023]
Abstract
OBJECTIVES To assess the magnitude and characterization of CT imaging protocols of patients receiving 50 or 100 mSv in a single day. METHODS In this multicentric retrospective study covering up to 279 hospitals from January 2015 to December 2019, the effective dose (E) as estimated by dose management system from dose length product of patients was filtered and grouped into per-day dose bands (≤ 20, > 20-50, > 50-70, > 70-100, > 100-200, > 200 mSv). Information on patient's age and imaging protocol was noted. The data were analyzed to determine the frequency of occurrence in each dose band. Top 20 CT imaging protocols that led to patients with a dose of ≥ 50 mSv in a single acquisition were identified and their relative frequency was estimated. RESULTS A total of approx. 4.3 million (4,283,738) CT exams were performed in approx. 3.9 million (3,880,524) patient-days indicating 9.41% had more than one CT exam in a single day. There were 31,058 (0.8%) patient-days with ≥ 50 mSv and 1191 (0.03%) with ≥ 100 mSv. Nearly 1/3rd patient-days reaching ≥ 50 mSv were of patients aged 50 years or younger. The top 20 CT imaging protocols that led to ≥ 50 mSv in a single day belonged to the body region (chest or abdomen and pelvis) and nearly one-third were angiographic studies. CONCLUSIONS In the first study of its kind, we report that patients with 50 mSv+ in a single day or a single exam are not rare. The information on imaging protocols leading to such doses and their frequency has been provided to help develop dose management strategies. KEY POINTS • Our study of 4,283,738 CT exams performed in 3,880,524 patient-days indicates 0.8% with 50 mSv+ and 0.03% with 100 mSv+ in a single day. • A total of 9.41% underwent more than one CT exam in a single day; nearly 1/3rd of those with 50 mSv+ were ≤ 50 years of age. • Identified top 20 CT imaging protocols that led to 50 mSv+ doses in a single exam. All belong to chest or abdomen and pelvis and nearly 1/3rd were angiographic studies.
Collapse
Affiliation(s)
- Madan M Rehani
- Massachusetts General Hospital, 55 Fruit Str, Boston, MA, 02114, USA. .,Radiology Department, Massachusetts General Hospital, 175 Cambridge Str., Suite 244, Boston, MA, 02114, USA.
| | - John Heil
- Imalogix Research Institute, Bryn Mawr, PA, 19010, USA
| | - Vinit Baliyan
- Massachusetts General Hospital, 55 Fruit Str, Boston, MA, 02114, USA
| |
Collapse
|
8
|
Snel GJH, Hernandez LM, Slart RHJA, Nguyen CT, Sosnovik DE, van Deursen VM, Dierckx RAJO, Velthuis BK, Borra RJH, Prakken NHJ. Validation of thoracic aortic dimensions on ECG-triggered SSFP as alternative to contrast-enhanced MRA. Eur Radiol 2020; 30:5794-5804. [PMID: 32506262 PMCID: PMC7554008 DOI: 10.1007/s00330-020-06963-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 04/07/2020] [Accepted: 05/15/2020] [Indexed: 01/16/2023]
Abstract
Objectives Assessment of thoracic aortic dimensions with non-ECG-triggered contrast-enhanced magnetic resonance angiography (CE-MRA) is accompanied with motion artefacts and requires gadolinium. To avoid both motion artefacts and gadolinium administration, we evaluated the similarity and reproducibility of dimensions measured on ECG-triggered, balanced steady-state free precession (SSFP) MRA as alternative to CE-MRA. Methods All patients, with varying medical conditions, referred for thoracic aortic examination between September 2016 and March 2018, who underwent non-ECG-triggered CE-MRA and SSFP-MRA (1.5 T) were retrospectively included (n = 30). Aortic dimensions were measured after double-oblique multiplanar reconstruction by two observers at nine landmarks predefined by literature guidelines. Image quality was scored at the sinus of Valsalva, mid-ascending aorta and mid-descending aorta by semi-automatically assessing the vessel sharpness. Results Aortic dimensions showed high agreement between non-ECG-triggered CE-MRA and SSFP-MRA (r = 0.99, p < 0.05) without overestimation or underestimation of aortic dimensions in SSFP-MRA (mean difference, 0.1 mm; limits of agreement, − 1.9 mm and 1.9 mm). Intra- and inter-observer variabilities were significantly smaller with SSFP-MRA for the sinus of Valsalva and sinotubular junction. Image quality of the sinus of Valsalva was significantly better with SSFP-MRA, as fewer images were of impaired quality (3/30) than in CE-MRA (21/30). Reproducibility of dimensions was significantly better in images scored as good quality compared to impaired quality in both sequences. Conclusions Thoracic aortic dimensions measured on SSFP-MRA and non-ECG-triggered CE-MRA were similar. As expected, SSFP-MRA showed better reproducibility close to the aortic root because of lesser motion artefacts, making it a feasible non-contrast imaging alternative. Key Points • SSFP-MRA provides similar dimensions as non-ECG-triggered CE-MRA. • Intra- and inter-observer reproducibilities improve for the sinus of Valsalva and sinotubular junction with SSFP-MRA. • ECG-triggered SSFP-MRA shows better image quality for landmarks close to the aortic root in the absence of cardiac motion. Electronic supplementary material The online version of this article (10.1007/s00330-020-06963-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- G J H Snel
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.
| | - L M Hernandez
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - R H J A Slart
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
- Department of Biomedical Photonic Imaging, University of Twente, Dienstweg 1, 7522 ND, Enschede, The Netherlands
| | - C T Nguyen
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 13th Street, Charlestown, MA, 02129, USA
- Cardiovascular Research Center, Massachusetts General Hospital, Harvard Medical School, 149 13th Street, Charlestown, MA, 02129, USA
| | - D E Sosnovik
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, 149 13th Street, Charlestown, MA, 02129, USA
- Cardiovascular Research Center, Massachusetts General Hospital, Harvard Medical School, 149 13th Street, Charlestown, MA, 02129, USA
- Division of Health Sciences and Technology, Harvard-MIT, 7 Massachusetts Avenue, Cambridge, MA, 02139, USA
| | - V M van Deursen
- Department of Cardiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - R A J O Dierckx
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - B K Velthuis
- Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands
| | - R J H Borra
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
- Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| | - N H J Prakken
- Department of Radiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands
| |
Collapse
|
9
|
Hu Z, Christodoulou AG, Wang N, Shaw JL, Song SS, Maya MM, Ishimori ML, Forbess LJ, Xiao J, Bi X, Han F, Li D, Fan Z. Magnetic resonance multitasking for multidimensional assessment of cardiovascular system: Development and feasibility study on the thoracic aorta. Magn Reson Med 2020; 84:2376-2388. [PMID: 32301164 DOI: 10.1002/mrm.28275] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Revised: 03/15/2020] [Accepted: 03/16/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop an MR multitasking-based multidimensional assessment of cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free data acquisition for a comprehensive evaluation of thoracic aortic diseases. METHODS The MT-MACS technique adopts a low-rank tensor image model with a cardiac time dimension for phase-resolved cine imaging and a T2 -prepared inversion-recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast-to-noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4-point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT-MACS and its corresponding 2D references. RESULTS The MT-MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright-blood (2.58 ± 0.46), dark-blood (2.58 ± 0.50), and gray-blood (2.17 ± 0.53) contrast weightings, respectively. The contrast-to-noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT-MACS and conventional 2D sequences. CONCLUSION The MT-MACS technique provides high-quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted.
Collapse
Affiliation(s)
- Zhehao Hu
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Department of Bioengineering, University of California, Los Angeles, California
| | - Anthony G Christodoulou
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Department of Medicine, University of California, Los Angeles, California
| | - Nan Wang
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Department of Bioengineering, University of California, Los Angeles, California
| | - Jaime L Shaw
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California
| | - Shlee S Song
- Department of Neurology, Cedars-Sinai Medical Center, Los Angeles, California
| | - Marcel M Maya
- Department of Imaging, Cedars-Sinai Medical Center, Los Angeles, California
| | - Mariko L Ishimori
- Department of Rheumatology, Cedars-Sinai Medical Center, Los Angeles, California
| | - Lindsy J Forbess
- Department of Rheumatology, Cedars-Sinai Medical Center, Los Angeles, California
| | - Jiayu Xiao
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California
| | | | - Fei Han
- Siemens Healthcare, Los Angeles, California
| | - Debiao Li
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Department of Bioengineering, University of California, Los Angeles, California.,Department of Medicine, University of California, Los Angeles, California
| | - Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Department of Bioengineering, University of California, Los Angeles, California.,Department of Medicine, University of California, Los Angeles, California
| |
Collapse
|
10
|
Guo J, Li D, Zhang Z. Intraluminal fibrous cord of the aorta in the differential diagnosis of aortic dissection. Cardiovasc Diagn Ther 2020; 9:596-600. [PMID: 32038949 DOI: 10.21037/cdt.2019.11.05] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A patient presented with an intraluminal fibrous cord in the distal segment of ascending aorta. On axial images, the fibrous cord had the appearance of an aortic dissection flap. Observation of continuous images and multiplanar reconstruction were critical for differential diagnosis. Volume render images showed both ends of the fibrous cord had tentiform attachments to the aorta inner wall, which indicating a congenital aorta anomaly. One possible hypothesis for the congenital variation might be the fifth primitive aortic arches remnant.
Collapse
Affiliation(s)
- Jingjing Guo
- Department of Radiology, Tianjin Huanhu Hospital, Tianjin 300350, China
| | - Dong Li
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin 300052, China
| | - Zhang Zhang
- Department of Radiology, Tianjin Medical University General Hospital, Tianjin 300052, China
| |
Collapse
|
11
|
Altamirano-Diaz L, Kassay AD, Serajelahi B, McIntyre CW, Filler G, Kharche SR. Arterial Hypertension and Unusual Ascending Aortic Dilatation in a Neonate With Acute Kidney Injury: Mechanistic Computer Modeling. Front Physiol 2019; 10:1391. [PMID: 31780955 PMCID: PMC6856675 DOI: 10.3389/fphys.2019.01391] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Accepted: 10/25/2019] [Indexed: 01/23/2023] Open
Abstract
Background Neonatal asphyxia caused kidney injury and severe hypertension in a newborn. An unusually dilatated ascending aorta developed. Dialysis and pharmacological treatment led to partial recovery of the ascending aortic diameters. It was hypothesized that the aortic dilatation may be associated with aortic stiffening, peripheral resistance, and cardiovascular changes. Mathematical modeling was used to better understand the potential causes of the hypertension, and to confirm our clinical treatment within the confines of the model's capabilities. Methods The patient's systolic arterial blood pressure showed hypertension. Echocardiographic exams showed ascending aorta dilatation during hypertension, which partially normalized upon antihypertensive treatment. To explore the underlying mechanisms of the aortic dilatation and hypertension, an existing lumped parameter hemodynamics model was deployed. Hypertension was simulated using realistic literature informed parameter values. It was also simulated using large parameter perturbations to demonstrate effects. Simulations were designed to permit examination of causal mechanisms. The hypertension inducing effects of aortic stiffnesses, vascular resistances, and cardiac hypertrophy on blood flow and pressure were simulated. Sensitivity analysis was used to stratify causes. Results In agreement with our clinical diagnosis, the model showed that an increase of aortic stiffness followed by augmentation of peripheral resistance are the prime causes of realistic hypertension. Increased left ventricular elastance may also cause hypertension. Ascending aortic pressure and flow increased in the simultaneous presence of left ventricle hypertrophy and augmented small vessel resistance, which indicate a plausible condition for ascending aorta dilatation. In case of realistic hypertension, sensitivity analysis showed that the treatment of both the large vessel stiffness and small vessel resistance are more important in comparison to cardiac hypertrophy. Conclusion and Discussion Large vessel stiffness was found to be the prime factor in arterial hypertension, which confirmed the clinical treatment. Treatment of cardiac hypertrophy appears to provide significant benefit but may be secondary to treatment of large vessel stiffness. The quantitative grading of pathophysiological mechanisms provided by the modeling may contribute to treatment recommendations. The model was limited due to a lack of data suitable to permit model identification.
Collapse
Affiliation(s)
- Luis Altamirano-Diaz
- Department of Paediatrics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Children's Health Research Institute, London, ON, Canada.,Paediatric Cardiopulmonary Research Laboratory, LHSC, London, ON, Canada
| | | | - Baran Serajelahi
- Department of Medicine, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Christopher W McIntyre
- Department of Paediatrics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Lawson Health Research Institute, London, ON, Canada.,Department of Medical Biophysics, Western University, London, ON, Canada
| | - Guido Filler
- Department of Paediatrics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Children's Health Research Institute, London, ON, Canada.,Lawson Health Research Institute, London, ON, Canada.,Department of Medical Biophysics, Western University, London, ON, Canada
| | - Sanjay R Kharche
- Lawson Health Research Institute, London, ON, Canada.,Department of Medicine, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.,Department of Medical Biophysics, Western University, London, ON, Canada
| |
Collapse
|
12
|
Baliyan V, Shaqdan K, Hedgire S, Ghoshhajra B. Vascular computed tomography angiography technique and indications. Cardiovasc Diagn Ther 2019; 9:S14-S27. [PMID: 31559151 DOI: 10.21037/cdt.2019.07.04] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Non-invasive cross-sectional imaging techniques play a crucial role in the assessment of the vascular disease processes. Computed tomography angiography (CTA) is an imaging method of choice for a wide range of vascular diseases that span across different vascular territories. A diagnostic quality CTA requires a robust imaging protocol tailored according to the physiologic state and vascular area of interest. This review article is aimed to provide an overview of the technical considerations and clinical applications of CTA.
Collapse
Affiliation(s)
- Vinit Baliyan
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Khalid Shaqdan
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Sandeep Hedgire
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Brian Ghoshhajra
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
13
|
Abstract
Diagnosis of the inflammatory aortopathies and importantly, their distinction in the later stages of disease from genetically mediated or acquired (degenerative) aortopathy remains a challenging clinical problem. Historically, the diagnosis of inflammatory aortopathy has required tissue sampling and pathological assessment. Although histological diagnosis remains an important diagnostic criterion, the ability to obtain sufficient tissue samples is problematic and requires invasive approaches that pose important risk. Continuing refinement in the capabilities of multimodality imaging, including ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography provides important insights into the broad spectrum of disease which comprise the inflammatory aortopathies. This review examines the current and emerging role of multimodality imaging in the evaluation of aortitis.
Collapse
Affiliation(s)
- John P Bois
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN
| | - Vidhu Anand
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN
| | | |
Collapse
|
14
|
Einspieler I, Henninger M, Mergen V, Wendorff H, Haller B, Eiber M, Rummeny EJ, Schwaiger M, Moog P, Thürmel K. Three-dimensional fat-saturated T1-weighted Cartesian volumetric interpolated breath-hold examination (VIBE) for the diagnosis of aortitis in patients with suspected large vessel vasculitis: a comparative study with 18F-FDG PET applying fully integrated PET/MRI. Clin Radiol 2019; 74:731.e11-731.e19. [PMID: 31130228 DOI: 10.1016/j.crad.2019.04.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 04/11/2019] [Indexed: 12/27/2022]
Abstract
AIM To evaluate the feasibility of T1-weighted (T1W) three-dimensional (3D) fat saturated Cartesian volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) sequence for the diagnosis of aortitis in patients with suspected large vessel vasculitis (LVV) applying fully integrated 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG) positron-emission tomography (PET)/MRI. MATERIAL AND METHODS Fourteen patients with aortitis and 14 patients with a negative study for aortitis using 18F-FDG PET as the standard of reference for the evaluation of inflammatory aortic involvement were included retrospectively. All patients were imaged at 3 T using T1W VIBE pre- and post-contrast. Four aortic segments were evaluated for image quality (IQ), diagnostic confidence (DC), and the degree of inflammatory activity (IA) using a Likert scale. Binomial and generalised estimating equation model tests were used to assess the diagnostic performance of T1W VIBE. Cohen's k was applied to test for interobserver reproducibility with respect to IA. Spearman's rank correlation coefficient was calculated to examine correlations between IQ, DC, IA, and PET results. RESULTS On a patient- and segment-based analysis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 85.7% and 59.8%, 100% and 100%, 100% and 100%, 87.5% and 68%, and 92.9% and 82.1%, respectively. IQ and DC were acceptable to good in all examinations and substantial interobserver agreement was observed for IA (Cohen's k = 0.69). IQ and DC as well as IA and 18F-FDG vessel wall uptake were significantly correlated (r=0.763 and 0.679, respectively; p<0.0001). CONCLUSION T1W 3D fat saturated VIBE MRI allows diagnosis of aortitis and may aid in the management of patients with suspected LVV.
Collapse
Affiliation(s)
- I Einspieler
- Department of Nuclear Medicine, Technische Universität München, Klinikum rechts der Isar, Munich, Germany; Department of Radiology, Technische Universität München, Klinikum rechts der Isar, Munich, Germany; Department of Radiology, University Hospital Regensburg, Regensburg, Germany.
| | - M Henninger
- Department of Nuclear Medicine, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - V Mergen
- Department of Nuclear Medicine, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - H Wendorff
- Department of Vascular Surgery, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - B Haller
- Department of Medical Statistics and Epidemiology, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - M Eiber
- Department of Nuclear Medicine, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - E J Rummeny
- Department of Radiology, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - M Schwaiger
- Department of Nuclear Medicine, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - P Moog
- Department of Nephrology and Rheumatology, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| | - K Thürmel
- Department of Nephrology and Rheumatology, Technische Universität München, Klinikum rechts der Isar, Munich, Germany
| |
Collapse
|