1
|
Connolly JE, Herrmann HC, Atluri P, Desai N, Fiorilli PN, Giri J, Li RH, Kobayashi T, Nathan AS, Szeto WY, Grimm JC. Transcatheter aortic valve replacement achieves similar predicted effective orifice area to surgical aortic valve replacement in bicuspid aortic stenosis. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2024; 66:21-26. [PMID: 38553277 DOI: 10.1016/j.carrev.2024.03.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/07/2024] [Accepted: 03/19/2024] [Indexed: 09/01/2024]
Abstract
BACKGROUND Studies comparing transcatheter and surgical aortic valve replacement (TAVR and SAVR) for patients with trileaflet aortic stenosis (AS) have found similar or larger effective orifice area (EOA) for TAVR prostheses. To our knowledge, no studies have compared EOA in patients undergoing TAVR versus SAVR for bicuspid AS. METHODS We retrospectively compared prosthetic valvular sizing and predicted EOA for patients with bicuspid AS undergoing TAVR or SAVR at our institution between January 1, 2016, and December 31, 2021. We excluded patients undergoing procedures for indications other than AS and those without a pre-procedural gated Chest CT. Comparisons included demographics, comorbidities, annular size, prosthetic valve size, predicted EOA and prosthesis-patient mismatch (PPM) for TAVR (N = 78) and SAVR (N = 74) cohorts. RESULTS TAVR patients had smaller pre-procedural annular area (501.7 mm2 vs. 571.8 mm2, p < 0.05) and annular perimeter (80.6 mm vs. 86.5 mm, p < 0.05), but larger mean implanted prosthetic valve size (26.4 mm vs 24.2 mm, p < 0.001) compared to SAVR patients. No differences were observed in predicted EOA, predicted EOA indexed to patient body surface area (EOAi), or predicted PPM grade between TAVR and SAVR groups, including in cohorts sorted by pre-procedural annular size. CONCLUSIONS For bicuspid AS patients undergoing aortic valve replacement, TAVR achieves similar predicted EOA to SAVR. These data support the use of TAVR in selected patients with bicuspid AS and can inform heart team discussions.
Collapse
Affiliation(s)
- John E Connolly
- Department of Internal Medicine, Johns Hopkins Hospital, Baltimore, MD 21224, USA
| | - Howard C Herrmann
- Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Pavan Atluri
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Nimesh Desai
- Division of Cardiovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Paul N Fiorilli
- Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Jay Giri
- Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Robert H Li
- Division of Cardiovascular Medicine, Penn Presbyterian Medical Center, Philadelphia, PA 19104, USA
| | - Taisei Kobayashi
- Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Ashwin S Nathan
- Division of Cardiovascular Medicine, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Wilson Y Szeto
- Division of Cardiovascular Surgery, Penn Presbyterian Medical Center, Philadelphia, PA 19104, USA
| | - Joshua C Grimm
- Institute for Cardiovascular Health, University of Texas Health Austin, Austin, TX 78712, USA.
| |
Collapse
|
2
|
Merdler I, Case B, Bhogal S, Reddy PK, Sawant V, Zhang C, Ali S, Ben-Dor I, Satler LF, Rogers T, Waksman R. Early experience with the Evolut FX self-expanding valve vs. Evolut PRO+ for patients with aortic stenosis undergoing TAVR. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 56:1-6. [PMID: 37453813 DOI: 10.1016/j.carrev.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/03/2023] [Accepted: 06/03/2023] [Indexed: 07/18/2023]
Abstract
BACKGROUND The Evolut FX system is the most recent generation of self-expandable transcatheter heart valve (THV) technology. This study aims to report the early experience and outcomes associated with this system. METHODS Our analysis included 200 consecutive patients who underwent transcatheter aortic valve replacement at our center from 2022 to 2023. The first cohort comprised the last 100 patients who received the Evolut PRO+ THV, while the second cohort included the first 100 patients who received the Evolut FX THV. The primary endpoints of the study were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria, which included technical success (at exit from procedure), device success (at discharge or at 30 days), and early safety (at 30 days). RESULTS The study groups demonstrated no significant differences in baseline characteristics, including co-morbidities, pre-procedural imaging, and echocardiography. VARC-3 technical success rate was 99 % for both valves. The VARC-3 device success rate for the Evolut FX was 92 % compared to 97 % for the Evolut PRO+ (p = 0.12), and VARC-3 early safety rate was 80.1 % for the Evolut PRO+ vs. 81.5 % for the Evolut FX (p = 0.82). The in-hospital permanent pacemaker implantation rate for the Evolut FX was 12 % compared to 9 % for the Evolut PRO+ (p = 0.21). There were no differences in clinical outcomes, such as mortality or stroke, between the two groups. CONCLUSIONS The Evolut FX THV performed well when used for patients with severe aortic stenosis, demonstrating high success with low complication rates when compared to an earlier generation of self-expanding THV.
Collapse
Affiliation(s)
- Ilan Merdler
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Brian Case
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Sukhdeep Bhogal
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Pavan K Reddy
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Vaishnavi Sawant
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Cheng Zhang
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Syed Ali
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Itsik Ben-Dor
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Lowell F Satler
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America
| | - Toby Rogers
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America; Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, United States of America
| | - Ron Waksman
- MedStar Heart & Vascular Institute, MedStar Washington Hospital Center, Washington, DC, United States of America; MedStar Georgetown University Hospital, Washington, DC, United States of America.
| |
Collapse
|
3
|
Bhogal S, Rogers T, Merdler I, Reddy P, Ali S, Shea C, Zhang C, Ben-Dor I, Satler LF, Waksman R. Evolut PRO/PRO+ versus Evolut R system for transcatheter aortic valve replacement. Int J Cardiol 2023; 389:131196. [PMID: 37479148 DOI: 10.1016/j.ijcard.2023.131196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 06/16/2023] [Accepted: 07/17/2023] [Indexed: 07/23/2023]
Abstract
BACKGROUND The self-expanding CoreValve Evolut PRO/PRO+ transcatheter aortic valve was designed to overcome the limitations of its forerunner, Evolut R. Evolut PRO/PRO+ offers the lowest delivery profile for 23-29 mm valves, with an external tissue wrap on all valve sizes. We compared safety and efficacy of Evolut PRO/PRO+ and Evolut R. METHODS We analyzed 300 patients enrolled in the EPROMPT Registry against a historical control cohort of 242 patients who received Evolut R. The two arms were matched (1:1) via propensity-score methodology by accounting for differences in Society of Thoracic Surgeons Predicted Risk of Mortality scores, yielding 440 patients. The endpoints included in-hospital safety clinical outcomes, all-cause mortality, and echocardiographic parameters at 30 days and 1 year. RESULTS After propensity-score matching, cardiac death (0.5% vs. 0.5%, p = 0.995), stroke (1.6% vs. 2.8%, p = 0.410), life-threatening bleeding (1.1% vs. 3.3%, p = 0.139), major vascular complications (0.5% vs. 0.9%, p = 0.653), and pacemaker implantation (16.9% vs. 13.6%, p = 0.345) were comparable between the Evolut PRO/PRO+ and Evolut R groups. Likewise, the rates of all-cause mortality were similar both at 30 days (0.5% vs. 1.4%, p = 0.315) and 1 year (1.8% vs. 4.1%, p = 0.159). The rates of moderate paravalvular leak (5.7% vs. 2.6%, p = 0.402), and mean gradient (7.27 ± 3.25 mmHg vs. 8.84 ± 4.36 mmHg, p = 0.105) were also comparable between groups at 1 year. CONCLUSION Our largest-to-date observational study suggests that the Evolut PRO/PRO+ system is safe and effective in treating severe aortic stenosis, with commensurate 30-day and 1-year mortality and similar 1-year echocardiographic hemodynamic outcomes in comparison to Evolut R.
Collapse
Affiliation(s)
- Sukhdeep Bhogal
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Toby Rogers
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA; Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Ilan Merdler
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Pavan Reddy
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Syed Ali
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Corey Shea
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Cheng Zhang
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Itsik Ben-Dor
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Lowell F Satler
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA
| | - Ron Waksman
- Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, DC, USA.
| |
Collapse
|
4
|
Trongtorsak A, Thangjui S, Adhikari P, Shrestha B, Kewcharoen J, Navaravong L, Kanjanauthai S, Attanasio S, Saudye HA. Gender Disparities after Transcatheter Aortic Valve Replacement with Newer Generation Transcatheter Heart Valves: A Systematic Review and Meta-Analysis. Med Sci (Basel) 2023; 11:medsci11020033. [PMID: 37218985 DOI: 10.3390/medsci11020033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/24/2023] Open
Abstract
Previous studies have demonstrated gender disparities in mortality and vascular complications after transcatheter aortic valve replacement (TAVR) with early generation transcatheter heart valves (THVs). It is unclear, however, whether gender-related differences persist with the newer generation THVs. We aim to assess gender disparities after TAVR with newer generation THVs. The MEDLINE and Embase databases were thoroughly searched from inception to April 2023 to identify studies that reported gender-specific outcomes after TAVR with newer generation THVs (Sapien 3, Corevalve Evolut R, and Evolut Pro). The outcomes of interest included 30-day mortality, 1-year mortality, and vascular complications. In total, 5 studies (4 databases) with a total of 47,933 patients (21,073 females and 26,860 males) were included. Ninety-six percent received TAVR via the transfemoral approach. The females had higher 30-day mortality rates (odds ratio (OR) = 1.53, 95% confidence interval (CI) 1.31-1.79, p-value (p) < 0.001) and vascular complications (OR = 1.43, 95% CI 1.23-1.65, p < 0.001). However, one-year mortality was similar between the two groups (OR = 0.78, 95% CI 0.61-1.00, p = 0.28). The female gender continues to be associated with higher 30-day mortality rates and vascular complications after TAVR with newer generation transcatheter heart valves, while there was no difference in 1-year mortality between the genders. More data is needed to explore the causes and whether we can improve TAVR outcomes in females.
Collapse
Affiliation(s)
- Angkawipa Trongtorsak
- Ascension Saint Francis Hospital, Internal Medicine Residency Program, Evanston, IL 60202, USA
| | - Sittinun Thangjui
- Bassett Healthcare Network, Internal Medicine Residency Program, New York, NY 13326, USA
| | - Pabitra Adhikari
- Ascension Saint Francis Hospital, Internal Medicine Residency Program, Evanston, IL 60202, USA
| | - Biraj Shrestha
- Reading Hospital-Tower Health, Internal Medicine Residency Program, West Reading, PA 19611, USA
| | - Jakrin Kewcharoen
- Division of Cardiovascular Medicine, Loma Linda University Health, Loma Linda, CA 92350, USA
| | - Leenhapong Navaravong
- Division of Cardiovascular Medicine, School of Medicine, University of Utah, Salt Lake City, UT 84112, USA
| | - Somsupha Kanjanauthai
- Division of Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90007, USA
| | - Steve Attanasio
- Rush University Medical Center, Division of Cardiovascular Medicine, Chicago, IL 60612, USA
| | - Hammad A Saudye
- Ascension Saint Francis Hospital, Division of Cardiovascular Medicine, Evanston, IL 60202, USA
| |
Collapse
|
5
|
Gozdek M, Kuźma Ł, Dąbrowski EJ, Janiak M, Pietrzak M, Skonieczna K, Woźnica M, Wydeheft L, Makhoul M, Matteucci M, Litwinowicz R, Kowalówka A, Wańha W, Pasierski M, Ronco D, Massimi G, Jiritano F, Fina D, Martucci G, Raffa GM, Suwalski P, Lorusso R, Meani P, Kowalewski M. Outcomes of Transcatheter Aortic Valve Implantation Comparing Medtronic's Evolut PRO and Evolut R: A Systematic Review and Meta-Analysis of Observational Studies. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:3439. [PMID: 36834131 PMCID: PMC9967567 DOI: 10.3390/ijerph20043439] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Revised: 02/09/2023] [Accepted: 02/14/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND Transcatheter aortic valve implantation (TAVI) has become a broadly acceptable alternative to AV surgery in patients with aortic stenosis (AS). New valve designs are becoming available to address the shortcomings of their predecessors and improve clinical outcomes. METHODS A systematic review and meta-analysis was carried out to compare Medtronic's Evolut PRO, a new valve, with the previous Evolut R design. Procedural, functional and clinical endpoints according to the VARC-2 criteria were assessed. RESULTS Eleven observational studies involving N = 12,363 patients were included. Evolut PRO patients differed regarding age (p < 0.001), sex (p < 0.001) and STS-PROM estimated risk. There was no difference between the two devices in terms of TAVI-related early complications and clinical endpoints. A 35% reduction of the risk of moderate-to-severe paravalvular leak (PVL) favoring the Evolut PRO was observed (RR 0.66, 95%CI, [0.52, 0.86] p = 0.002; I2 = 0%). Similarly, Evolut PRO-treated patients demonstrated a reduction of over 35% in the risk of serious bleeding as compared with the Evolut R (RR 0.63, 95%CI, [0.41, 0.96]; p = 0.03; I2 = 39%), without differences in major vascular complications. CONCLUSIONS The evidence shows good short-term outcomes of both the Evolut PRO and Evolut R prostheses, with no differences in clinical and procedural endpoints. The Evolut PRO was associated with a lower rate of moderate-to-severe PVL and major bleeding.
Collapse
Affiliation(s)
- Mirosław Gozdek
- Department of Cardiology, Hospital of the Ministry of Interior, 72-122 Bydgoszcz, Poland
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Łukasz Kuźma
- Department of Invasive Cardiology, Medical University of Bialystok, 15-540 Bialystok, Poland
| | - Emil Julian Dąbrowski
- Department of Invasive Cardiology, Medical University of Bialystok, 15-540 Bialystok, Poland
| | - Michał Janiak
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Martyna Pietrzak
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Karolina Skonieczna
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Mikołaj Woźnica
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Lidia Wydeheft
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
| | - Maged Makhoul
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery, Harefield Hospital, London UB9 6JH, UK
| | - Matteo Matteucci
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Cardiac Surgery Unit, ASST dei Sette Laghi, Department of Medicine and Surgery, University of Insubria, 21100 Varese, Italy
- Cardiothoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), The Cardiovascular Research Institute Maastricht (CARIM), 6229 ER Maastricht, The Netherlands
| | - Radosław Litwinowicz
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery, Regional Specialist Hospital, 86-300 Grudziądz, Poland
| | - Adam Kowalówka
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery, Upper-Silesian Heart Center, 40-752 Katowice, Poland
- Department of Cardiac Surgery, Faculty of Medical Sciences, Medical University of Silesia, 40-752 Katowice, Poland
| | - Wojciech Wańha
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery, School of Medicine in Katowice, Medical University of Silesia, 40-752 Katowice, Poland
| | - Michał Pasierski
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery and Transplantology, Central Clinical Hospital of the Ministry of Interior, Centre of Postgraduate Medical Education, 02-507 Warsaw, Poland
| | - Daniele Ronco
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Cardiothoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), The Cardiovascular Research Institute Maastricht (CARIM), 6229 ER Maastricht, The Netherlands
| | - Giulio Massimi
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Cardiothoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), The Cardiovascular Research Institute Maastricht (CARIM), 6229 ER Maastricht, The Netherlands
| | - Federica Jiritano
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy
| | - Dario Fina
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiothoracic, Vascular Anesthesia and Intensive Care Unit, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico, San Donato Milanese, 20097 Milan, Italy
| | - Gennaro Martucci
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Anesthesia and Intensive Care, Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (IRCCS-ISMETT), 90100 Palermo, Italy
| | - Giuseppe Maria Raffa
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, Istituto di Ricovero e Cura a Carattere Scientifico-Istituto Mediterraneo per i Trapianti e Terapie ad Alta Specializzazione (IRCCS-ISMETT), 90100 Palermo, Italy
| | - Piotr Suwalski
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiac Surgery and Transplantology, Central Clinical Hospital of the Ministry of Interior, Centre of Postgraduate Medical Education, 02-507 Warsaw, Poland
| | - Roberto Lorusso
- Cardiothoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), The Cardiovascular Research Institute Maastricht (CARIM), 6229 ER Maastricht, The Netherlands
| | - Paolo Meani
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Department of Cardiothoracic, Vascular Anesthesia and Intensive Care Unit, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Policlinico, San Donato Milanese, 20097 Milan, Italy
| | - Mariusz Kowalewski
- Thoracic Research Centre, Collegium Medicum Nicolaus Copernicus University, Innovative Medical Forum, 85-094 Bydgoszcz, Poland
- Cardiothoracic Surgery Department, Heart and Vascular Centre, Maastricht University Medical Centre (MUMC), The Cardiovascular Research Institute Maastricht (CARIM), 6229 ER Maastricht, The Netherlands
- Department of Cardiac Surgery and Transplantology, Central Clinical Hospital of the Ministry of Interior, Centre of Postgraduate Medical Education, 02-507 Warsaw, Poland
| |
Collapse
|
6
|
Wienemann H, Hof A, Ludwig S, Veulemans V, Sedaghat A, Iliadis C, Meertens M, Macherey S, Hohmann C, Kuhn E, Al-Kassou B, Wilde N, Schofer N, Bleiziffer S, Maier O, Kelm M, Baldus S, Rudolph TK, Adam M, Mauri V. Transcatheter aortic valve implantation with different self-expanding devices-a propensity score-matched multicenter comparison. Hellenic J Cardiol 2022; 70:1-9. [PMID: 36538975 DOI: 10.1016/j.hjc.2022.12.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVE Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.
Collapse
Affiliation(s)
- Hendrik Wienemann
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Alexander Hof
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Sebastian Ludwig
- University Hamburg, University Heart and Vascular Center Hamburg, Department of Cardiology, Hamburg, Germany
| | - Verena Veulemans
- Heinrich-Heine University, University Hospital Düsseldorf, Department of Cardiology, Pneumology, and Vascular Medicine, Düsseldorf, Germany
| | - Alexander Sedaghat
- University of Bonn, University Hospital Bonn, Clinic II for Internal Medicine, Bonn, Germany
| | - Christos Iliadis
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Max Meertens
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Sascha Macherey
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Christopher Hohmann
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Elmar Kuhn
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Department of Cardiothoracic Surgery, Cologne, Germany
| | - Baravan Al-Kassou
- University of Bonn, University Hospital Bonn, Clinic II for Internal Medicine, Bonn, Germany
| | - Nihal Wilde
- University of Bonn, University Hospital Bonn, Clinic II for Internal Medicine, Bonn, Germany
| | - Niklas Schofer
- University Hamburg, University Heart and Vascular Center Hamburg, Department of Cardiology, Hamburg, Germany
| | - Sabine Bleiziffer
- Ruhr University Bochum, Heart and Diabetes Centre North Rhine Westphalia, Clinic for Thoracic and Cardiovascular Surgery, Bad Oeynhausen, Germany
| | - Oliver Maier
- Heinrich-Heine University, University Hospital Düsseldorf, Department of Cardiology, Pneumology, and Vascular Medicine, Düsseldorf, Germany
| | - Malte Kelm
- Heinrich-Heine University, University Hospital Düsseldorf, Department of Cardiology, Pneumology, and Vascular Medicine, Düsseldorf, Germany
| | - Stephan Baldus
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Tanja Katharina Rudolph
- Ruhr University Bochum, Heart and Diabetes Center North Rhine Westphalia, Clinic for General and Interventional Cardiology, Bad Oeynhausen, Germany
| | - Matti Adam
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany
| | - Victor Mauri
- University of Cologne, Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, Cologne, Germany.
| |
Collapse
|
7
|
Panagides V, Mesnier J, Nuche J, Delarochellière R, Paradis JM, Kalavrouziotis D, Dumont E, Mohammadi S, Rodes-Cabau J. From the Evolut Pro to the Evolut FX self-expanding transcatheter aortic valve replacement systems: current status and future perspectives. Expert Rev Med Devices 2022; 19:561-569. [PMID: 36005274 DOI: 10.1080/17434440.2022.2113386] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Since the initial experience with the CoreValve (Medtronic, Minneapolis, Minnesota), there have been continuous iterations of this valve system in order to improve procedural success and reduce periprocedural complications. The Evolut Pro, Pro+, and FX are the latest generations of this transcatheter heart valve (THV). AREAS COVERED This review paper aims to analyze the main characteristics and clinical evidence about the Evolut Pro THV and summarize the main iterations of the newer generation Evolut FX valve system. EXPERT OPINION The Evolut Pro system has been associated with good clinical outcomes and excellent valve hemodynamic performance including reduced rates of paravalvular leaks. Technical enhancements to improve valve positioning, orientation, and vascular access have been implemented in the newer generation Evolut FX system.
Collapse
Affiliation(s)
- Vassili Panagides
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Jules Mesnier
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Jorge Nuche
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Robert Delarochellière
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Jean-Michel Paradis
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Dimitri Kalavrouziotis
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Eric Dumont
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Siamak Mohammadi
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| | - Josep Rodes-Cabau
- Department of Cardiology, Quebec Heart and Lung Institute, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Québec, QC, Canada
| |
Collapse
|