1
|
Chevallier O, Guillen K, Comby PO, Mouillot T, Falvo N, Bardou M, Midulla M, Aho-Glélé LS, Loffroy R. Safety, Efficacy, and Outcomes of N-Butyl Cyanoacrylate Glue Injection through the Endoscopic or Radiologic Route for Variceal Gastrointestinal Bleeding: A Systematic Review and Meta-Analysis. J Clin Med 2021; 10:jcm10112298. [PMID: 34070534 PMCID: PMC8198169 DOI: 10.3390/jcm10112298] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Revised: 05/17/2021] [Accepted: 05/17/2021] [Indexed: 12/12/2022] Open
Abstract
We performed a systematic review and meta-analysis of published studies to assess the efficacy, safety, and outcomes of N-butyl cyanoacrylate (NBCA) injection for the treatment of variceal gastrointestinal bleeding (GIB). The MEDLINE/PubMed, EMBASE, and SCOPUS databases were searched for English-language studies published from January 1980 to December 2019 and including patients who had injection of NBCA for variceal GIB. Two independent reviewers extracted and evaluated the data from eligible studies. Exclusion criteria were sample size < 5, article reporting the use of NBCA with other embolic agents, no extractable data, and duplicate reports. NBCA was injected during endoscopy in 42 studies and through a direct percutaneous approach for stomal varices in 1 study. The study’s endpoints were: Technical success, 30-day rebleeding, and 30-day overall and major complications. The estimated overall rates were computed with 95% confidence intervals, based on each study rate, weighted by the number of patients involved in each study. In total, 43 studies with 3484 patients were included. The technical success rate was 94.1% (95% CI: 91.6–96.1%), the 30-day rebleeding rate was 24.2% (18.9–29.9%), and 30-day overall and major complications occurred in 15.9% (11.2–21.3%) and 5.3% (3.3–7.8%) of patients, respectively. For treating variceal GIB, NBCA injection is a safe and effective method that demonstrates high technical success rate and very low major complication rate.
Collapse
Affiliation(s)
- Olivier Chevallier
- Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, ImViA Laboratory-EA 7535, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (N.F.); (M.M.)
| | - Kévin Guillen
- Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, ImViA Laboratory-EA 7535, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (N.F.); (M.M.)
| | - Pierre-Olivier Comby
- Department of Neuroradiology and Emergency Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France;
| | - Thomas Mouillot
- Department of Gastroenterology and Hepatology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (T.M.); (M.B.)
| | - Nicolas Falvo
- Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, ImViA Laboratory-EA 7535, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (N.F.); (M.M.)
| | - Marc Bardou
- Department of Gastroenterology and Hepatology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (T.M.); (M.B.)
| | - Marco Midulla
- Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, ImViA Laboratory-EA 7535, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (N.F.); (M.M.)
| | - Ludwig-Serge Aho-Glélé
- Department of Biostatistics and Epidemiology, François-Mitterrand University Hospital, 14 Rue Paul, Gaffarel, BP 77908, 21079 Dijon, France;
| | - Romaric Loffroy
- Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, ImViA Laboratory-EA 7535, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France; (O.C.); (K.G.); (N.F.); (M.M.)
- Correspondence: ; Tel.: +33-380-293-358
| |
Collapse
|
2
|
Sun X, Zhao Q, Sun P, Yao Z, Wang R. Metal artifact reduction using mono-energy images combined with metal artifact reduction software in spectral computed tomography: a study on phantoms. Quant Imaging Med Surg 2020; 10:1515-1525. [PMID: 32676369 DOI: 10.21037/qims-19-936] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND This study aimed to evaluate the effectiveness of spectral computed tomography (CT) mono-energy imaging combined with metal artifact reduction software (MARs) for metal implant artifact reduction using a phantom. METHODS A quantitative standard phantom with 9 cylinders was used to simulate the attenuation of the different tissues of the human body around the metal implant. Groups A and B were divided according to conventional CT scan mode and spectral CT scan mode. Three sets of reconstructed images, including 120 kVp-like + MARs images, mono-energy images (MonoE), and MonoE + MARs images, were generated after spectral CT scanning. High-attenuation artifacts and low-attenuation artifacts were observed around the coil in the images of groups A and B. The CT values (Hounsfield unit) and standard deviation (SD) values of the artifacts were measured, and the artifact index and hardening artifact removal rate were calculated. RESULTS Compared to conventional poly-energy CT images, for high-attenuation and low-attenuation artifacts, the artifact indices of 120 kVp-like + MARs, MonoE, and MonoE + MARs images were all reduced significantly. The hardening artifact removal rates of the high-attenuation and low-attenuation artifacts of 120 kVp-like + MARs images were 82% and 92%, respectively. The hardening artifact removal rate of the high-attenuation and low-attenuation artifacts of MonoE and MonoE + MARs images increased with the mono-energy level. CONCLUSIONS Spectral CT using the 120 kVp-like + MARs, 110-140 keV MonoE, and MonoE + MARs reconstruction methods can reduce metal implant artifacts in varying degrees. MonoE + MARs reconstruction was the best method for reducing metal artifacts.
Collapse
Affiliation(s)
- Xiaoli Sun
- Department of Radiology, Beijing Shijitan Hospital, Peking University Ninth School of Clinical Medicine, Capital Medical University, Beijing, China
| | - Qingqing Zhao
- Department of Radiology, Beijing Shijitan Hospital, Peking University Ninth School of Clinical Medicine, Capital Medical University, Beijing, China
| | - Pengtao Sun
- Department of Radiology, Beijing Shijitan Hospital, Peking University Ninth School of Clinical Medicine, Capital Medical University, Beijing, China
| | - Zhipeng Yao
- Department of Radiology, Beijing Shijitan Hospital, Peking University Ninth School of Clinical Medicine, Capital Medical University, Beijing, China
| | - Rengui Wang
- Department of Radiology, Beijing Shijitan Hospital, Peking University Ninth School of Clinical Medicine, Capital Medical University, Beijing, China
| |
Collapse
|