1
|
Wang Y, Duan Y, Guo D, Lv H, Li Q, Liu X, Qiao N, Meng H, Zhang X, Lan L, Liu X, Liu X. Value of circulating tumor cell assisting low-dose computed tomography in screening pulmonary nodules based on existing liquid biopsy techniques: a systematic review with meta-analysis and trial sequential analysis. Clin Transl Oncol 2024:10.1007/s12094-024-03556-8. [PMID: 38869739 DOI: 10.1007/s12094-024-03556-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Accepted: 06/04/2024] [Indexed: 06/14/2024]
Abstract
OBJECTIVE This study aims to assess the diagnostic utility of circulating tumor cells (CTCs) in conjunction with low-dose computed tomography (LDCT) for differentiating between benign and malignant pulmonary nodules and to substantiate the foundation for their integration into clinical practice. METHODS A systematic literature review was performed independently by two researchers utilizing databases including PubMed, Web of Science, The Cochrane Library, Embase, and Medline, to collate studies up to September 15, 2023, that investigated the application of CTCs in diagnosing pulmonary nodules. A meta-analysis was executed employing Stata 15.0 and Revman 5.4 to calculate the pooled sensitivity, specificity, positive and negative likelihood ratios (PLR and NLR), diagnostic odds ratio (DOR), and the area under the receiver operating characteristic curve (AUC). Additionally, trial sequential analysis was conducted using dedicated TSA software. RESULTS The selection criteria identified 16 studies, encompassing a total of 3409 patients. The meta-analysis revealed that CTCs achieved a pooled sensitivity of 0.84 (95% CI 0.80 to 0.87), specificity of 0.80 (95% CI 0.73 to 0.86), PLR of 4.23 (95% CI 3.12 to 5.72), NLR of 0.20 (95% CI 0.16 to 0.25), DOR of 20.92 (95% CI 13.52 to 32.36), and AUC of 0.89 (95% CI 0.86 to 0.93). CONCLUSIONS Circulating tumor cells demonstrate substantial diagnostic accuracy in distinguishing benign from malignant pulmonary nodules. The incorporation of CTCs into the diagnostic protocol can significantly augment the diagnostic efficacy of LDCT in screening for malignant lung diseases.
Collapse
Affiliation(s)
- Yixian Wang
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Yuqing Duan
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Dingjie Guo
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Hongbo Lv
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Qiong Li
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Xuan Liu
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Na Qiao
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Hengyu Meng
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Xin Zhang
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Linwei Lan
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China
| | - Xiumin Liu
- Department of Clinical Laboratory, The Second Hospital of Jilin University, Changchun, Jilin, 130041, China.
| | - Xin Liu
- Department of Epidemiology and Statistics, School of Public Health, Jilin University, Changchun, Jilin, 130021, China.
| |
Collapse
|
2
|
Christensen J, Prosper AE, Wu CC, Chung J, Lee E, Elicker B, Hunsaker AR, Petranovic M, Sandler KL, Stiles B, Mazzone P, Yankelevitz D, Aberle D, Chiles C, Kazerooni E. ACR Lung-RADS v2022: Assessment Categories and Management Recommendations. J Am Coll Radiol 2024; 21:473-488. [PMID: 37820837 DOI: 10.1016/j.jacr.2023.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 08/08/2023] [Accepted: 09/21/2023] [Indexed: 10/13/2023]
Abstract
The ACR created the Lung CT Screening Reporting and Data System (Lung-RADS) in 2014 to standardize the reporting and management of screen-detected pulmonary nodules. Lung-RADS was updated to version 1.1 in 2019 and revised size thresholds for nonsolid nodules, added classification criteria for perifissural nodules, and allowed for short-interval follow-up of rapidly enlarging nodules that may be infectious in etiology. Lung-RADS v2022, released in November 2022, provides several updates including guidance on the classification and management of atypical pulmonary cysts, juxtapleural nodules, airway-centered nodules, and potentially infectious findings. This new release also provides clarification for determining nodule growth and introduces stepped management for nodules that are stable or decreasing in size. This article summarizes the current evidence and expert consensus supporting Lung-RADS v2022.
Collapse
Affiliation(s)
- Jared Christensen
- Vice Chair and Professor of Radiology, Department of Radiology, Duke University, Durham, North Carolina; Chair, ACR Lung-RADS Committee.
| | - Ashley Elizabeth Prosper
- Assistant Professor and Section Chief of Cardiothoracic Imaging, Department of Radiological Sciences, University of California, Los Angeles, California
| | - Carol C Wu
- Professor of Diagnostic Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Jonathan Chung
- Professor of Radiology Vice Chair of Quality Section Chief of Cardiopulmonary Imaging, University of Chicago, Chicago, Illinois
| | - Elizabeth Lee
- Clinical Associate Professor, Radiology, Michigan Medicine, Ann Arbor, Michigan
| | - Brett Elicker
- Chief of the Cardiac & Pulmonary Imaging Section, University of California, San Francisco, California
| | - Andetta R Hunsaker
- Brigham and Women's Hospital, Boston, Massachusetts; Associate Professor Harvard Medical School Chief Division of Thoracic Imaging
| | - Milena Petranovic
- Instructor, Radiology, Harvard Medical School Divisional Quality Director, Thoracic Imaging and Intervention, Radiology, Massachusetts General Hospital, Boston, Massachusetts
| | - Kim L Sandler
- Associate Professor, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Brendon Stiles
- Professor and Chair, Thoracic Surgery and Surgical Oncology, Montefiore Health System, Albert Einstein College of Medicine, Bronx, New York
| | | | | | - Denise Aberle
- Professor of Radiology, Department of Radiological Sciences; David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Caroline Chiles
- Professor of Radiology Director, Lung Screening Program, Atrium Health Wake Forest, Winston-Salem, North Carolina
| | - Ella Kazerooni
- Professor of Radiology & Internal Medicine and Associate Chief Clinical Officer for Diagnostics, Michigan Medicine/University of Michigan Medical School, Ann Arbor, Michigan; Clinical Information Management, University of Michigan Medical Group
| |
Collapse
|
3
|
Christensen J, Prosper AE, Wu CC, Chung J, Lee E, Elicker B, Hunsaker AR, Petranovic M, Sandler KL, Stiles B, Mazzone P, Yankelevitz D, Aberle D, Chiles C, Kazerooni E. ACR Lung-RADS v2022: Assessment Categories and Management Recommendations. Chest 2024; 165:738-753. [PMID: 38300206 DOI: 10.1016/j.chest.2023.10.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2024] Open
Abstract
The American College of Radiology created the Lung CT Screening Reporting and Data System (Lung-RADS) in 2014 to standardize the reporting and management of screen-detected pulmonary nodules. Lung-RADS was updated to version 1.1 in 2019 and revised size thresholds for nonsolid nodules, added classification criteria for perifissural nodules, and allowed for short-interval follow-up of rapidly enlarging nodules that may be infectious in etiology. Lung-RADS v2022, released in November 2022, provides several updates including guidance on the classification and management of atypical pulmonary cysts, juxtapleural nodules, airway-centered nodules, and potentially infectious findings. This new release also provides clarification for determining nodule growth and introduces stepped management for nodules that are stable or decreasing in size. This article summarizes the current evidence and expert consensus supporting Lung-RADS v2022.
Collapse
Affiliation(s)
- Jared Christensen
- Vice Chair and Professor of Radiology, Department of Radiology, Duke University, Durham, North Carolina; Chair, ACR Lung-RADS Committee.
| | - Ashley Elizabeth Prosper
- Assistant Professor and Section Chief of Cardiothoracic Imaging, Department of Radiological Sciences, University of California, Los Angeles, California
| | - Carol C Wu
- Professor of Diagnostic Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Jonathan Chung
- Professor of Radiology Vice Chair of Quality Section Chief of Cardiopulmonary Imaging, University of Chicago, Chicago, Illinois
| | - Elizabeth Lee
- Clinical Associate Professor, Radiology, Michigan Medicine, Ann Arbor, Michigan
| | - Brett Elicker
- Chief of the Cardiac & Pulmonary Imaging Section, University of California, San Francisco, California
| | - Andetta R Hunsaker
- Brigham and Women's Hospital, Boston, Massachusetts; Associate Professor Harvard Medical School Chief Division of Thoracic Imaging
| | - Milena Petranovic
- Instructor, Radiology, Harvard Medical School Divisional Quality Director, Thoracic Imaging and Intervention, Radiology, Massachusetts General Hospital, Boston, Massachusetts
| | - Kim L Sandler
- Associate Professor, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Brendon Stiles
- Professor and Chair, Thoracic Surgery and Surgical Oncology, Montefiore Health System, Albert Einstein College of Medicine, Bronx, New York
| | | | | | - Denise Aberle
- Professor of Radiology, Department of Radiological Sciences; David Geffen School of Medicine at UCLA, Los Angeles, California
| | - Caroline Chiles
- Professor of Radiology Director, Lung Screening Program, Atrium Health Wake Forest, Winston-Salem, North Carolina
| | - Ella Kazerooni
- Professor of Radiology & Internal Medicine and Associate Chief Clinical Officer for Diagnostics, Michigan Medicine/University of Michigan Medical School, Ann Arbor, Michigan; Clinical Information Management, University of Michigan Medical Group
| |
Collapse
|
4
|
Melton CA, Freese P, Zhou Y, Shenoy A, Bagaria S, Chang C, Kuo CC, Scott E, Srinivasan S, Cann G, Roychowdhury-Saha M, Chang PY, Singh AH. A Novel Tissue-Free Method to Estimate Tumor-Derived Cell-Free DNA Quantity Using Tumor Methylation Patterns. Cancers (Basel) 2023; 16:82. [PMID: 38201510 PMCID: PMC10777919 DOI: 10.3390/cancers16010082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 12/07/2023] [Accepted: 12/20/2023] [Indexed: 01/12/2024] Open
Abstract
Estimating the abundance of cell-free DNA (cfDNA) fragments shed from a tumor (i.e., circulating tumor DNA (ctDNA)) can approximate tumor burden, which has numerous clinical applications. We derived a novel, broadly applicable statistical method to quantify cancer-indicative methylation patterns within cfDNA to estimate ctDNA abundance, even at low levels. Our algorithm identified differentially methylated regions (DMRs) between a reference database of cancer tissue biopsy samples and cfDNA from individuals without cancer. Then, without utilizing matched tissue biopsy, counts of fragments matching the cancer-indicative hyper/hypo-methylated patterns within DMRs were used to determine a tumor methylated fraction (TMeF; a methylation-based quantification of the circulating tumor allele fraction and estimate of ctDNA abundance) for plasma samples. TMeF and small variant allele fraction (SVAF) estimates of the same cancer plasma samples were correlated (Spearman's correlation coefficient: 0.73), and synthetic dilutions to expected TMeF of 10-3 and 10-4 had estimated TMeF within two-fold for 95% and 77% of samples, respectively. TMeF increased with cancer stage and tumor size and inversely correlated with survival probability. Therefore, tumor-derived fragments in the cfDNA of patients with cancer can be leveraged to estimate ctDNA abundance without the need for a tumor biopsy, which may provide non-invasive clinical approximations of tumor burden.
Collapse
|
5
|
Guedes Pinto E, Penha D, Ravara S, Monaghan C, Hochhegger B, Marchiori E, Taborda-Barata L, Irion K. Factors influencing the outcome of volumetry tools for pulmonary nodule analysis: a systematic review and attempted meta-analysis. Insights Imaging 2023; 14:152. [PMID: 37741928 PMCID: PMC10517915 DOI: 10.1186/s13244-023-01480-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/08/2023] [Indexed: 09/25/2023] Open
Abstract
Health systems worldwide are implementing lung cancer screening programmes to identify early-stage lung cancer and maximise patient survival. Volumetry is recommended for follow-up of pulmonary nodules and outperforms other measurement methods. However, volumetry is known to be influenced by multiple factors. The objectives of this systematic review (PROSPERO CRD42022370233) are to summarise the current knowledge regarding factors that influence volumetry tools used in the analysis of pulmonary nodules, assess for significant clinical impact, identify gaps in current knowledge and suggest future research. Five databases (Medline, Scopus, Journals@Ovid, Embase and Emcare) were searched on the 21st of September, 2022, and 137 original research studies were included, explicitly testing the potential impact of influencing factors on the outcome of volumetry tools. The summary of these studies is tabulated, and a narrative review is provided. A subset of studies (n = 16) reporting clinical significance were selected, and their results were combined, if appropriate, using meta-analysis. Factors with clinical significance include the segmentation algorithm, quality of the segmentation, slice thickness, the level of inspiration for solid nodules, and the reconstruction algorithm and kernel in subsolid nodules. Although there is a large body of evidence in this field, it is unclear how to apply the results from these studies in clinical practice as most studies do not test for clinical relevance. The meta-analysis did not improve our understanding due to the small number and heterogeneity of studies testing for clinical significance. CRITICAL RELEVANCE STATEMENT: Many studies have investigated the influencing factors of pulmonary nodule volumetry, but only 11% of these questioned their clinical relevance in their management. The heterogeneity among these studies presents a challenge in consolidating results and clinical application of the evidence. KEY POINTS: • Factors influencing the volumetry of pulmonary nodules have been extensively investigated. • Just 11% of studies test clinical significance (wrongly diagnosing growth). • Nodule size interacts with most other influencing factors (especially for smaller nodules). • Heterogeneity among studies makes comparison and consolidation of results challenging. • Future research should focus on clinical applicability, screening, and updated technology.
Collapse
Affiliation(s)
- Erique Guedes Pinto
- R. Marquês de Ávila E Bolama, Universidade da Beira Interior Faculdade de Ciências da Saúde, 6201-001, Covilhã, Portugal.
| | - Diana Penha
- R. Marquês de Ávila E Bolama, Universidade da Beira Interior Faculdade de Ciências da Saúde, 6201-001, Covilhã, Portugal
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Dr, Liverpool, L14 3PE, UK
| | - Sofia Ravara
- R. Marquês de Ávila E Bolama, Universidade da Beira Interior Faculdade de Ciências da Saúde, 6201-001, Covilhã, Portugal
| | - Colin Monaghan
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Dr, Liverpool, L14 3PE, UK
| | | | - Edson Marchiori
- Faculdade de Medicina, Universidade Federal Do Rio de Janeiro, Bloco K - Av. Carlos Chagas Filho, 373 - 2º Andar, Sala 49 - Cidade Universitária da Universidade Federal Do Rio de Janeiro, Rio de Janeiro - RJ, 21044-020, Brasil
- Faculdade de Medicina, Universidade Federal Fluminense, Av. Marquês Do Paraná, 303 - Centro, Niterói - RJ, 24220-000, Brasil
| | - Luís Taborda-Barata
- R. Marquês de Ávila E Bolama, Universidade da Beira Interior Faculdade de Ciências da Saúde, 6201-001, Covilhã, Portugal
| | - Klaus Irion
- Manchester University NHS Foundation Trust, Manchester Royal Infirmary, Oxford Rd, Manchester, M13 9WL, UK
| |
Collapse
|
6
|
Liu YC, Liang CH, Wu YJ, Chen CS, Tang EK, Wu FZ. Managing Persistent Subsolid Nodules in Lung Cancer: Education, Decision Making, and Impact of Interval Growth Patterns. Diagnostics (Basel) 2023; 13:2674. [PMID: 37627933 PMCID: PMC10453827 DOI: 10.3390/diagnostics13162674] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/07/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023] Open
Abstract
With the popularization of lung cancer screening, many persistent subsolid nodules (SSNs) have been identified clinically, especially in Asian non-smokers. However, many studies have found that SSNs exhibit heterogeneous growth trends during long-term follow ups. This article adopted a narrative approach to extensively review the available literature on the topic to explore the definitions, rationale, and clinical application of different interval growths of subsolid pulmonary nodule management and follow-up strategies. The development of SSN growth thresholds with different growth patterns could support clinical decision making with follow-up guidelines to reduce over- and delayed diagnoses. In conclusion, using different SSN growth thresholds could optimize the follow-up management and clinical decision making of SSNs in lung cancer screening programs. This could further reduce the lung cancer mortality rate and potential harm from overdiagnosis and over management.
Collapse
Affiliation(s)
- Yung-Chi Liu
- Department of Radiology, Xiamen Chang Gung Hospital, Xiamen 361028, China;
- Department of Imaging Technology Division, Xiamen Chang Gung Hospital, Xiamen 361028, China
- Department of Healthcare Administration Department, Xiamen Chang Gung Hospital, Xiamen 361028, China
| | - Chia-Hao Liang
- Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei 112304, Taiwan;
| | - Yun-Ju Wu
- Department of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung 81362, Taiwan;
- Department of Software Engineering and Management, National Kaohsiung Normal University, Kaohsiung 80201, Taiwan
| | - Chi-Shen Chen
- Physical Examination Center, Kaohsiung Veterans General Hospital, Kaohsiung 81362, Taiwan;
| | - En-Kuei Tang
- Department of Surgery, Kaohsiung Veterans General Hospital, Kaohsiung 813414, Taiwan;
| | - Fu-Zong Wu
- Department of Radiology, Kaohsiung Veterans General Hospital, Kaohsiung 81362, Taiwan;
- School of Medicine, College of Medicine, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan
- Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Institute of Education, National Sun Yat-Sen University, Kaohsiung 804241, Taiwan
| |
Collapse
|
7
|
Bianconi F, Fravolini ML, Palumbo B. Size measurement of lung nodules on CT: which diameter is most stable to inter-observer variability? Clin Imaging 2023; 99:38-40. [PMID: 37060680 DOI: 10.1016/j.clinimag.2023.03.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 03/03/2023] [Accepted: 03/21/2023] [Indexed: 04/17/2023]
Abstract
Indeterminate lung nodules detected on CT are common findings in the clinical practice, and the correct assessment of their size is critical for patient evaluation and management. We compared the stability of three definitions of nodule diameter (Feret's mean diameter, Martin's mean diameter and area-equivalent diameter) to inter-observer variability on a population of 336 solid nodules from 207 subjects. We found that inter-observer agreement was highest with Martin's mean diameter (intra-class correlation coefficient = 0.977, 95% Confidence interval = 0.977-0.978), followed by area-equivalent diameter (0.972, 0.971-0.973) and Feret's mean diameter (0.965, 0.964-0.966). The differences were statistically significant. In conclusion, although all the three diameter definitions achieved very good inter-observer agreement (ICC > 0.96), Martin's mean diameter was significantly better than the others. Future guidelines may consider adopting Martin's mean diameter as an alternative to the currently used Feret's (caliper) diameter for assessing the size of lung nodules on CT.
Collapse
Affiliation(s)
- Francesco Bianconi
- Department of Engineering, Università degli Studi di Perugia, Via Goffredo Duranti, 93 - 06125 Perugia, Italy.
| | - Mario Luca Fravolini
- Department of Engineering, Università degli Studi di Perugia, Via Goffredo Duranti, 93 - 06125 Perugia, Italy
| | - Barbara Palumbo
- Section of Nuclear Medicine and Health Physics, Department of Medicine and Surgery, Università degli Studi di Perugia, Piazzale Gambuli, 1 - 06129 Perugia, Italy
| |
Collapse
|
8
|
Menon AR, Cheema A, Hou S, Attwood KM, White T, James G, Xu B, Petroziello M, Roche CL, Kurenov S, Kauffman EC. Stability of renal parenchymal volume and function during active surveillance of renal oncocytoma patients. Urol Oncol 2023; 41:208.e15-208.e23. [PMID: 36842877 PMCID: PMC10959122 DOI: 10.1016/j.urolonc.2023.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/28/2022] [Accepted: 01/09/2023] [Indexed: 02/28/2023]
Abstract
INTRODUCTION AND OBJECTIVE To evaluate whether significant loss in ipsilateral renal parenchymal volume (IRPV) and renal function occurs during active surveillance (AS) of renal oncocytoma (RO) patients. METHODS Renal function (estimated glomerular filtration rate, eGFR) dynamics were retrospectively analyzed in 32 consecutive biopsy-diagnosed RO patients managed with AS at a National Comprehensive Cancer Network institute. Three-dimensional kidney and tumor reconstructions were generated and IRPV was calculated using volumetry software (Myrian®) for all patients with manually estimated RO growth >+10 cm3. GFR and IRPV were compared at AS initiation vs. the last follow-up using 2-sided paired t-tests. The correlation between change in IRPV and change in RO size or GFR was tested using a Spearman coefficient. RESULTS With median follow-up of 37 months, there was no significant change between initial vs. last eGFR (median 71.0 vs. 70.5 ml/min/1.73 m2, P = 0.50; median change -3.0 ml/min/1.73 m2). Among patients (n = 17) with RO growth >+10 cm3 during AS (median growth +28.6 cm3, IQR +16.9- + 46.5 cm3), IRPV generally remained stable (median change +0.5%, IQR -1.2%- + 1.2%), with only 2 cases surpassing 5% loss. No IRPV loss was detected among any patient within the top tertile of RO growth magnitude. RO growth magnitude did not correlate with loss of either IRPV (ρ = -0.30, P = 0.24) or eGFR (ρ = -0.16, P = 0.40), including among patient subsets with lower initial eGFR. Study limitations include a lack of long-term follow-up. CONCLUSIONS Volumetry is a promising novel tool to measure kidney and tumor tissue changes during AS. Our study using volumetry indicates that clinically significant loss of IRPV or eGFR is uncommon and unrelated to tumor growth among untreated RO patients with intermediate follow-up. These findings support that AS is in general functionally safe for RO patients, however longer study is needed to determine safety durability, particularly among uncommon ≥cT2 RO variants.
Collapse
Affiliation(s)
- Arun R Menon
- Department of Urology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Amandip Cheema
- Department of Urology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Surui Hou
- Department of Biostatistics and Bioinformatics, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Kristopher M Attwood
- Department of Biostatistics and Bioinformatics, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Tashionna White
- Department of Urology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Gaybrielle James
- Department of Urology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Bo Xu
- Department of Pathology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Michael Petroziello
- Department of Radiology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Charles L Roche
- Department of Radiology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Sergei Kurenov
- Department of Surgical Oncology, Roswell Park Comprehensive Cancer Center, Buffalo, NY
| | - Eric C Kauffman
- Department of Urology, Roswell Park Comprehensive Cancer Center, Buffalo, NY; Department of Cancer Genetics, Roswell Park Comprehensive Cancer Center, Buffalo, NY.
| |
Collapse
|
9
|
Contextualizing the Role of Volumetric Analysis in Pulmonary Nodule Assessment: AJR Expert Panel Narrative Review. AJR Am J Roentgenol 2023; 220:314-329. [PMID: 36129224 DOI: 10.2214/ajr.22.27830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Pulmonary nodules are managed on the basis of their size and morphologic characteristics. Radiologists are familiar with assessing nodule size by measuring diameter using manually deployed electronic calipers. Size may also be assessed with 3D volumetric measurements (referred to as volumetry) obtained with software. Nodule size and growth are more accurately assessed with volumetry than on the basis of diameter, and the evidence supporting clinical use of volumetry has expanded, driven by its use in lung cancer screening nodule management algorithms in Europe. The application of volumetry has the potential to reduce recommendations for imaging follow-up of indeterminate solid nodules without impacting cancer detection. Although changes in scanning conditions and volumetry software packages can lead to variation in volumetry results, ongoing technical advances have improved the reliability of calculated volumes. Volumetry is now the primary method for determining size of solid nodules in the European lung cancer screening position statement and British Thoracic Society recommendations. The purposes of this article are to review technical aspects, advantages, and limitations of volumetry and, by considering specific scenarios, to contextualize the use of volumetry with respect to its importance in morphologic evaluation, its role in predicting malignancy in risk models, and its practical impact on nodule management. Implementation challenges and areas requiring further evidence are also highlighted.
Collapse
|
10
|
Gross CF, Jungblut L, Schindera S, Messerli M, Fretz V, Frauenfelder T, Martini K. Comparability of Pulmonary Nodule Size Measurements among Different Scanners and Protocols: Should Diameter Be Favorized over Volume? Diagnostics (Basel) 2023; 13:diagnostics13040631. [PMID: 36832118 PMCID: PMC9955074 DOI: 10.3390/diagnostics13040631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023] Open
Abstract
BACKGROUND To assess the impact of the lung cancer screening protocol recommended by the European Society of Thoracic Imaging (ESTI) on nodule diameter, volume, and density throughout different computed tomography (CT) scanners. METHODS An anthropomorphic chest phantom containing fourteen different-sized (range 3-12 mm) and CT-attenuated (100 HU, -630 HU and -800 HU, termed as solid, GG1 and GG2) pulmonary nodules was imaged on five CT scanners with institute-specific standard protocols (PS) and the lung cancer screening protocol recommended by ESTI (ESTI protocol, PE). Images were reconstructed with filtered back projection (FBP) and iterative reconstruction (REC). Image noise, nodule density and size (diameter/volume) were measured. Absolute percentage errors (APEs) of measurements were calculated. RESULTS Using PE, dosage variance between different scanners tended to decrease compared to PS, and the mean differences were statistically insignificant (p = 0.48). PS and PE(REC) showed significantly less image noise than PE(FBP) (p < 0.001). The smallest size measurement errors were noted with volumetric measurements in PE(REC) and highest with diametric measurements in PE(FBP). Volume performed better than diameter measurements in solid and GG1 nodules (p < 0.001). However, in GG2 nodules, this could not be observed (p = 0.20). Regarding nodule density, REC values were more consistent throughout different scanners and protocols. CONCLUSION Considering radiation dose, image noise, nodule size, and density measurements, we fully endorse the ESTI screening protocol including the use of REC. For size measurements, volume should be preferred over diameter.
Collapse
Affiliation(s)
- Colin F. Gross
- Diagnostic and Interventional Radiology, University Hospital Zurich, 8091 Zurich, Switzerland
- Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland
| | - Lisa Jungblut
- Diagnostic and Interventional Radiology, University Hospital Zurich, 8091 Zurich, Switzerland
- Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland
| | | | - Michael Messerli
- Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland
- Nuclear Medicine, University Hospital Zurich, 8091 Zurich, Switzerland
| | - Valentin Fretz
- Division for Radiology and Nuclear Medicine, Cantonal Hospital Winterthur, 8400 Winterthur, Switzerland
| | - Thomas Frauenfelder
- Diagnostic and Interventional Radiology, University Hospital Zurich, 8091 Zurich, Switzerland
- Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland
| | - Katharina Martini
- Diagnostic and Interventional Radiology, University Hospital Zurich, 8091 Zurich, Switzerland
- Faculty of Medicine, University of Zurich, 8006 Zurich, Switzerland
- Correspondence:
| |
Collapse
|
11
|
He Y, Xiong Z, Tian D, Zhang J, Chen J, Li Z. Natural progression of persistent pure ground-glass nodules 10 mm or smaller: long-term observation and risk factor assessment. Jpn J Radiol 2023; 41:605-616. [PMID: 36607551 DOI: 10.1007/s11604-022-01382-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Accepted: 12/26/2022] [Indexed: 01/07/2023]
Abstract
PURPOSE Semi-automatic segmentation was used to investigate the natural progression of pure ground-glass nodules (pGGNs) of 5-10 mm in long-term follow-up and to analyze independent risk factors for subsequent growth. MATERIALS AND METHODS A total of 154 pGGNs of 5-10 mm from 132 patients with 698 follow-up CT scans were retrospectively identified. Subsequently, enrolled pGGNs were semiautomatically segmented on initial and follow-up CT to obtain diameter, density and volume, thus calculating mass, volume doubling time (VDT), and mass doubling time (MDT). Kaplan‒Meier analysis and multivariate Cox proportional risk regression were performed to explore independent predictors of pGGN growth. We analyzed growth differences among different pathological results of pGGNs confirmed by surgery. The prognosis was analyzed using the total diameter or solid size of the nodules on the last preoperative CT. RESULTS Among the 85 (55.2%) pGGNs with growth, 5.9%, 51.8%, and 80.0% showed growth within 1, 3, and 5 years, respectively. The median VDT and MDT were 1206.4 (range 349.8-5134.4) days and 1161.3 (range 339.4-6630.4) days, respectively. The multivariate Cox risk regression analysis showed that mean CT attenuation (m-CTA) [hazard ratio (HR) = 2.098, p = 0.010] and roundness index (HR = 1.892, p = 0.021) were independent risk factors for pGGN growth. In total, 67.6% of surgically resected and growing pGGNs were invasive non-mucinous adenocarcinoma (IA), including 2 cases of endpoint events, showing a PSN with solid components of 5.6 mm and a solid nodule with a diameter of 19.9 mm. CONCLUSIONS pGGNs of 5-10 mm showed an indolent clinical course. Follow-up CT imaging of pGGNs in the latter half of the first two years should be a rational management strategy. Small pGGNs with a larger overall m-CTA and roundness index on baseline CT are more likely to grow.
Collapse
Affiliation(s)
- Yifan He
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Zhongshan, Xigang District, Dalian, 116011, China
| | - Ziqi Xiong
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Zhongshan, Xigang District, Dalian, 116011, China
| | - Di Tian
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Zhongshan, Xigang District, Dalian, 116011, China
| | - Jingyu Zhang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Zhongshan, Xigang District, Dalian, 116011, China
| | - Jianzhou Chen
- Shanghai United Imaging Intelligence, Co., Ltd., Shanghai, China
| | - Zhiyong Li
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Zhongshan, Xigang District, Dalian, 116011, China.
| |
Collapse
|
12
|
Abstract
Lung cancer is a leading cause of cancer death in the United States and globally with the majority of lung cancer cases attributable to cigarette smoking. Given the high societal and personal cost of a diagnosis of lung cancer including that most cases of lung cancer when diagnosed are found at a late stage, work over the past 40 years has aimed to detect lung cancer earlier when curative treatment is possible. Screening trials using chest radiography and sputum failed to show a reduction in lung cancer mortality however multiple studies using low dose CT have shown the ability to detect lung cancer early and a survival benefit to those screened. This review will discuss the history of lung cancer screening, current recommendations and screening guidelines, and implementation and components of a lung cancer screening program.
Collapse
|
13
|
Wang Y, Zhou C, Chan H, Hadjiiski LM, Chughtai A, Kazerooni EA. Hybrid U-Net-based deep learning model for volume segmentation of lung nodules in CT images. Med Phys 2022; 49:7287-7302. [PMID: 35717560 PMCID: PMC10087884 DOI: 10.1002/mp.15810] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 04/28/2022] [Accepted: 06/02/2022] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVE Accurate segmentation of the lung nodule in computed tomography images is a critical component of a computer-assisted lung cancer detection/diagnosis system. However, lung nodule segmentation is a challenging task due to the heterogeneity of nodules. This study is to develop a hybrid deep learning (H-DL) model for the segmentation of lung nodules with a wide variety of sizes, shapes, margins, and opacities. MATERIALS AND METHODS A dataset collected from Lung Image Database Consortium image collection containing 847 cases with lung nodules manually annotated by at least two radiologists with nodule diameters greater than 7 mm and less than 45 mm was randomly split into 683 training/validation and 164 independent test cases. The 50% consensus consolidation of radiologists' annotation was used as the reference standard for each nodule. We designed a new H-DL model combining two deep convolutional neural networks (DCNNs) with different structures as encoders to increase the learning capabilities for the segmentation of complex lung nodules. Leveraging the basic symmetric U-shaped architecture of U-Net, we redesigned two new U-shaped deep learning (U-DL) models that were expanded to six levels of convolutional layers. One U-DL model used a shallow DCNN structure containing 16 convolutional layers adapted from the VGG-19 as the encoder, and the other used a deep DCNN structure containing 200 layers adapted from DenseNet-201 as the encoder, while the same decoder with only one convolutional layer at each level was used in both U-DL models, and we referred to them as the shallow and deep U-DL models. Finally, an ensemble layer was used to combine the two U-DL models into the H-DL model. We compared the effectiveness of the H-DL, the shallow U-DL and the deep U-DL models by deploying them separately to the test set. The accuracy of volume segmentation for each nodule was evaluated by the 3D Dice coefficient and Jaccard index (JI) relative to the reference standard. For comparison, we calculated the median and minimum of the 3D Dice and JI over the individual radiologists who segmented each nodule, referred to as M-Dice, min-Dice, M-JI, and min-JI. RESULTS For the 164 test cases with 327 nodules, our H-DL model achieved an average 3D Dice coefficient of 0.750 ± 0.135 and an average JI of 0.617 ± 0.159. The radiologists' average M-Dice was 0.778 ± 0.102, and the average M-JI was 0.651 ± 0.127; both were significantly higher than those achieved by the H-DL model (p < 0.05). The radiologists' average min-Dice (0.685 ± 0.139) and the average min-JI (0.537 ± 0.153) were significantly lower than those achieved by the H-DL model (p < 0.05). The results indicated that the H-DL model approached the average performance of radiologists and was superior to the radiologist whose manual segmentation had the min-Dice and min-JI. Moreover, the average Dice and average JI achieved by the H-DL model were significantly higher than those achieved by the individual shallow U-DL model (Dice of 0.745 ± 0.139, JI of 0.611 ± 0.161; p < 0.05) or the individual deep U-DL model alone (Dice of 0.739 ± 0.145, JI of 0.604 ± 0.163; p < 0.05). CONCLUSION Our newly developed H-DL model outperformed the individual shallow or deep U-DL models. The H-DL method combining multilevel features learned by both the shallow and deep DCNNs could achieve segmentation accuracy comparable to radiologists' segmentation for nodules with wide ranges of image characteristics.
Collapse
Affiliation(s)
- Yifan Wang
- Department of RadiologyThe University of MichiganAnn ArborMichiganUSA
| | - Chuan Zhou
- Department of RadiologyThe University of MichiganAnn ArborMichiganUSA
| | - Heang‐Ping Chan
- Department of RadiologyThe University of MichiganAnn ArborMichiganUSA
| | | | - Aamer Chughtai
- Department of RadiologyThe University of MichiganAnn ArborMichiganUSA
| | - Ella A. Kazerooni
- Department of RadiologyThe University of MichiganAnn ArborMichiganUSA
| |
Collapse
|
14
|
Grenier PA, Brun AL, Mellot F. The Potential Role of Artificial Intelligence in Lung Cancer Screening Using Low-Dose Computed Tomography. Diagnostics (Basel) 2022; 12:diagnostics12102435. [PMID: 36292124 PMCID: PMC9601207 DOI: 10.3390/diagnostics12102435] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 10/04/2022] [Accepted: 10/06/2022] [Indexed: 11/16/2022] Open
Abstract
Two large randomized controlled trials of low-dose CT (LDCT)-based lung cancer screening (LCS) in high-risk smoker populations have shown a reduction in the number of lung cancer deaths in the screening group compared to a control group. Even if various countries are currently considering the implementation of LCS programs, recurring doubts and fears persist about the potentially high false positive rates, cost-effectiveness, and the availability of radiologists for scan interpretation. Artificial intelligence (AI) can potentially increase the efficiency of LCS. The objective of this article is to review the performances of AI algorithms developed for different tasks that make up the interpretation of LCS CT scans, and to estimate how these AI algorithms may be used as a second reader. Despite the reduction in lung cancer mortality due to LCS with LDCT, many smokers die of comorbid smoking-related diseases. The identification of CT features associated with these comorbidities could increase the value of screening with minimal impact on LCS programs. Because these smoking-related conditions are not systematically assessed in current LCS programs, AI can identify individuals with evidence of previously undiagnosed cardiovascular disease, emphysema or osteoporosis and offer an opportunity for treatment and prevention.
Collapse
Affiliation(s)
- Philippe A. Grenier
- Department of Clinical Research and Innovation, Hôpital Foch, 92150 Suresnes, France
- Correspondence:
| | | | | |
Collapse
|
15
|
Intra- and Inter-Reader Variations in Lung Nodule Measurements: Influences of Nodule Size, Location, and Observers. Diagnostics (Basel) 2022; 12:diagnostics12102319. [PMID: 36292008 PMCID: PMC9600531 DOI: 10.3390/diagnostics12102319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/21/2022] [Accepted: 09/21/2022] [Indexed: 11/17/2022] Open
Abstract
(1) Background: Accurate measurement of lung-nodule size is necessary, but whether a three-dimensional volume measurement is better or more reliable than the one-dimensional method is still unclear. This study aimed to investigate the intra- and inter-reader variations according to nodule type, size, three-dimensional volume measurements, and one-dimensional linear measurements. (2) Methods: This retrospective study included computed tomography (CT) examinations of lung nodules and volume measurements performed from October to December 2016. Two radiologists independently performed all measurements. Intra-class correlation coefficients (ICC) and Bland-Altman plots were used for analysis. (3) Results: The overall variability in the calculated volume was larger than when using the semiautomatic volume measurement. Nodules <6 mm tended to have larger variability than nodules ≥6 mm in both one-dimensional and calculated volume measurements. The isolated type showed smaller variability in both intra- and inter-reader comparisons. The juxta-vascular type showed the largest variability in both one-dimensional and calculated volume measurements. The variability was decreased when using the 3D volume semiautomated software. (4) Conclusions: The present study suggests that 3D semiautomatic volume measurements showed lower variability than the calculated volume measurement. Nodule size and location influence measurement variability. The intra- and inter-reader variabilities in nodule volume measurement were considerable.
Collapse
|
16
|
Lee JH, Hwang EJ, Lim WH, Goo JM. Determination of the optimum definition of growth evaluation for indeterminate pulmonary nodules detected in lung cancer screening. PLoS One 2022; 17:e0274583. [PMID: 36108077 PMCID: PMC9477274 DOI: 10.1371/journal.pone.0274583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 08/30/2022] [Indexed: 11/19/2022] Open
Abstract
Objective
To determine the optimum definition of growth for indeterminate pulmonary nodules detected in lung cancer screening.
Materials and methods
Individuals with indeterminate nodules as defined by volume of 50–500 mm3 (solid nodules) and solid component volume of 50–500 mm3 or average diameter of non-solid component ≥8 mm (part-solid nodules) on baseline lung cancer screening low-dose chest CT (LDCT) were included. The average diameters and volumes of the nodules were measured on baseline and follow-up LDCTs with semi-automated segmentation. Sensitivities and specificities for lung cancer diagnosis of nodule growth defined by a) percentage volume growth ≥25% (defined in the NELSON study); b) absolute diameter growth >1.5 mm (defined in the Lung-RADS version 1.1); and c) subjective decision by a radiologist were evaluated. Sensitivities and specificities of diagnostic referral based on various thresholds of volume doubling time (VDT) were also evaluated.
Results
Altogether, 115 nodules (one nodule per individual; 93 solid and 22 part-solid nodules; 105 men; median age, 68 years) were evaluated (median follow-up interval: 201 days; interquartile range: 127–371 days). Percentage volume growth ≥25% exhibited higher sensitivity but lower specificity than those of diametrical measurement compared to absolute diameter growth >1.5 mm (sensitivity, 69.2% vs. 42.3%, p = 0.023; specificity, 82.0% vs. 96.6%, p = 0.002). The radiologist had an equivalent sensitivity (53.9%; p = 0.289) but higher specificity (98.9%; p = 0.002) compared to those of volume growth, but did not differ from those of diameter growth (p>0.05 both in sensitivity and specificity). Compared to the VDT threshold of 600 days (sensitivity, 61.5%; specificity, 87.6%), VDT thresholds ≤200 and ≤300 days exhibited significantly lower sensitivity (30.8%, p = 0.013) and higher specificity (94.4%, p = 0.041), respectively.
Conclusion
Growth evaluation of screening-detected indeterminate nodules with volumetric measurement exhibited higher sensitivity but lower specificity compared to diametric measurements.
Collapse
Affiliation(s)
- Jong Hyuk Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Cancer Research Institute, Seoul National University, Seoul, Korea
| | - Eui Jin Hwang
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Cancer Research Institute, Seoul National University, Seoul, Korea
- * E-mail:
| | - Woo Hyeon Lim
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
| | - Jin Mo Goo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
- Cancer Research Institute, Seoul National University, Seoul, Korea
| |
Collapse
|
17
|
Liang X, Liu M, Li M, Zhang L. Clinical and CT Features of Subsolid Pulmonary Nodules With Interval Growth: A Systematic Review and Meta-Analysis. Front Oncol 2022; 12:929174. [PMID: 35860567 PMCID: PMC9289285 DOI: 10.3389/fonc.2022.929174] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 06/09/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundEstablishing risk-based follow-up management strategies is crucial to the surveillance of subsolid pulmonary nodules (SSNs). However, the risk factors for SSN growth are not currently clear. This study aimed to perform a systematic review and meta-analysis to identify clinical and CT features correlated with SSN growth.MethodsRelevant studies were retrieved from Web of Science, PubMed, Cochrane Library, and EMBASE. The correlations of clinical and CT features with SSN growth were pooled using a random-effects model or fixed-effects model depending on heterogeneity, which was examined by the Q test and I2 test. Pooled odds ratio (OR) or pooled standardized mean differences (SMD) based on univariate analyses were calculated to assess the correlation of clinical and CT features with SSN growth. Pooled ORs based on multivariate analyses were calculated to find out independent risk factors to SSN growth. Subgroup meta-analysis was performed based on nodule consistency (pure ground-glass nodule (pGGN) and part-solid nodule (PSN). Publication bias was examined using funnel plots.ResultsNineteen original studies were included, consisting of 2444 patients and 3012 SSNs. The median/mean follow-up duration of these studies ranged from 24.2 months to 112 months. Significant correlations were observed between SSN growth and eighteen features. Male sex, history of lung cancer, nodule size > 10 mm, nodule consistency, and age > 65 years were identified as independent risk factors for SSN growth based on multivariate analyses results. Eight features, including male sex, smoking history, nodule size > 10 mm, larger nodule size, air bronchogram, higher mean CT attenuation, well-defined border, and lobulated margin were detected to be significantly correlated with pGGNs growth. Smoking history showed no significant correlation with pGGN growth based on the multivariate analysis results.ConclusionsEighteen clinical and CT features were identified to be correlated with SSN growth, among which male sex, history of lung cancer, nodule size > 10 mm, nodule consistency and age > 65 years were independent risk factors while history of lung cancer was not correlated with pGGN growth. These factors should be considered when making risk-based follow-up plans for SSN patients.
Collapse
|
18
|
Godoy MCB, Lago EAD, Pria HRFD, Shroff GS, Strange CD, Truong MT. Pearls and Pitfalls in Lung Cancer CT Screening. Semin Ultrasound CT MR 2022; 43:246-256. [PMID: 35688535 DOI: 10.1053/j.sult.2022.03.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Annual LDCT lung cancer screening is recommended by the United States Preventive Services Task Force (USPSTF) for high-risk population based on the results from the National Lung Cancer Screening Trial (NLST) that showed a significant (20%) reduction in lung cancer-specific mortality rate with the use of annual low-dose computed tomography (LDCT) screening. More recently, the benefits of lung cancer screening were confirmed by the Dutch- Belgian NELSON trial in Europe. With the implementation of lung screening in large scale, knowledge of the limitations related to false positive, false negative and other potential pitfalls is essential to avoid misdiagnosis. This review outlines the most common potential pitfalls in the characterization of screen-detected lung nodules that include artifacts in LDCT, benign nodules that mimic lung cancer, and causes of false negative evaluations of lung cancer with LDCT and PET/CT studies. Awareness of the spectrum of potential pitfalls in pulmonary nodule detection and characterization, including equivocal or atypical presentations, is important for avoiding misinterpretation that can alter patient management.
Collapse
Affiliation(s)
- Myrna C B Godoy
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Eduardo A Dal Lago
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | | | - Girish S Shroff
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Chad D Strange
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| | - Mylene T Truong
- Department of Thoracic Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX
| |
Collapse
|
19
|
Darçot E, Jreige M, Rotzinger DC, Gidoin Tuyet Van S, Casutt A, Delacoste J, Simons J, Long O, Buela F, Ledoux JB, Prior JO, Lovis A, Beigelman-Aubry C. Comparison Between Magnetic Resonance Imaging and Computed Tomography in the Detection and Volumetric Assessment of Lung Nodules: A Prospective Study. Front Med (Lausanne) 2022; 9:858731. [PMID: 35573012 PMCID: PMC9096346 DOI: 10.3389/fmed.2022.858731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 03/25/2022] [Indexed: 11/22/2022] Open
Abstract
Rationale and Objectives Computed tomography (CT) lung nodule assessment is routinely performed and appears very promising for lung cancer screening. However, the radiation exposure through time remains a concern. With the overall goal of an optimal management of indeterminate lung nodules, the objective of this prospective study was therefore to evaluate the potential of optimized ultra-short echo time (UTE) MRI for lung nodule detection and volumetric assessment. Materials and Methods Eight (54.9 ± 13.2 years) patients with at least 1 non-calcified nodule ≥4 mm were included. UTE under high-frequency non-invasive ventilation (UTE-HF-NIV) and in free-breathing at tidal volume (UTE-FB) were investigated along with volumetric interpolated breath-hold examination at full inspiration (VIBE-BH). Three experienced readers assessed the detection rate of nodules ≥4 mm and ≥6 mm, and reported their location, 2D-measurements and solid/subsolid nature. Volumes were measured by two experienced readers. Subsequently, two readers assessed the detection and volume measurements of lung nodules ≥4mm in gold-standard CT images with soft and lung kernel reconstructions. Volumetry was performed with lesion management software (Carestream, Rochester, New York, USA). Results UTE-HF-NIV provided the highest detection rate for nodules ≥4 mm (n = 66) and ≥6 mm (n = 32) (35 and 50%, respectively). No dependencies were found between nodule detection and their location in the lung with UTE-HF-NIV (p > 0.4), such a dependency was observed for two readers with VIBE-BH (p = 0.002 and 0.03). Dependencies between the nodule's detection and their size were noticed among readers and techniques (p < 0.02). When comparing nodule volume measurements, an excellent concordance was observed between CT and UTE-HF-NIV, with an overestimation of 13.2% by UTE-HF-NIV, <25%-threshold used for nodule's growth, conversely to VIBE-BH that overestimated the nodule volume by 28.8%. Conclusion UTE-HF-NIV is not ready to replace low-dose CT for lung nodule detection, but could be used for follow-up studies, alternating with CT, based on its volumetric accuracy.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.,Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland
| | - Mario Jreige
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - David C Rotzinger
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.,Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland
| | - Stacey Gidoin Tuyet Van
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Alessio Casutt
- Department of Pulmonology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Jean Delacoste
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.,Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland
| | - Julien Simons
- Department of Physiotherapy, Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
| | - Olivier Long
- Department of Physiotherapy, Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
| | - Flore Buela
- Department of Physiotherapy, Lausanne University Hospital (CHUV) and University of Lausanne, Lausanne, Switzerland
| | - Jean-Baptiste Ledoux
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.,Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - John O Prior
- Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland.,Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital (CHUV), Lausanne, Switzerland
| | - Alban Lovis
- Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland.,Department of Pulmonology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland
| | - Catherine Beigelman-Aubry
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Lausanne, Switzerland.,Faculty of Biology and Medicine, University of Lausanne (UNIL), Lausanne, Switzerland
| |
Collapse
|
20
|
Du Y, Li Y, Dorrius MD, Sidorenkov G, Vonder M, Vliegenthart R, Heuvelmans MA, Cui X, Ye Z, de Bock GH. Comparison of National Comprehensive Cancer Network and European Position Statement protocols for nodule management in low-dose computed tomography lung cancer screening in a general Chinese population. J Thorac Dis 2022; 13:6855-6865. [PMID: 35070370 PMCID: PMC8743405 DOI: 10.21037/jtd-21-1312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 10/14/2021] [Indexed: 11/26/2022]
Abstract
Background Low-dose computed tomography (LDCT) lung cancer screening often refers individuals to unnecessary examinations. This study aims to compare the European Position Statement (EUPS) and National Comprehensive Cancer Network (NCCN) protocols in management of participants at baseline screening round. Methods LDCT lung cancer screening was prospectively performed in a Chinese asymptomatic population aged 40–74 years. A total of 1,000 consecutive baseline LDCT scans were read twice independently. All screen-detected lung nodules by the first reader were included. The first reader manually measured the diameter of lung nodules (NCCN protocol), and the second reader semi-automatically measured the volume and diameter (EUPS volume and diameter protocols). The protocols were used to classify the participants into three management groups: next screening round, short-term repeat LDCT scan and referral to a pulmonologist. Groups were compared using Wilcoxon test for paired samples. Number of lung cancers by protocols was provided. Results Of the 1,000 participants (61.4±6.7 years old), 168 lung nodules in 124 participants were visually detected and manually measured in the first reading, and re-measured semi-automatically. Applying the NCCN protocol, EUPS volume and diameter protocol, the proportion of referrals among all participants was 0.6%, 1.9%, and 1.4%, respectively. The proportion of short-term repeat scans was 4.5%, 9.7% and 4.5%, respectively. Among the 10 lung cancer patients, one would have been diagnosed earlier if the EUPS volume protocol would have been followed. Conclusions In a first round screening in a Chinese general population, the lower threshold for referral in the EUPS protocol as compared to the NCCN protocol, leads to more referrals to a pulmonologist, with the potential of earlier cancer diagnosis. The EUPS volume protocol recommends fewer participants to short-term repeat LDCT scan than the EUPS diameter protocol. Follow-up studies should show the impact of both protocols on (interval) cancer diagnosis.
Collapse
Affiliation(s)
- Yihui Du
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Yanju Li
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Centre for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Monique D Dorrius
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.,Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Grigory Sidorenkov
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Marleen Vonder
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Rozemarijn Vliegenthart
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Marjolein A Heuvelmans
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Xiaonan Cui
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Centre for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Zhaoxiang Ye
- Department of Radiology, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Centre for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
| | - Geertruida H de Bock
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
21
|
Deep Learning Applications in Computed Tomography Images for Pulmonary Nodule Detection and Diagnosis: A Review. Diagnostics (Basel) 2022; 12:diagnostics12020298. [PMID: 35204388 PMCID: PMC8871398 DOI: 10.3390/diagnostics12020298] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/21/2022] [Accepted: 01/22/2022] [Indexed: 12/26/2022] Open
Abstract
Lung cancer has one of the highest mortality rates of all cancers and poses a severe threat to people’s health. Therefore, diagnosing lung nodules at an early stage is crucial to improving patient survival rates. Numerous computer-aided diagnosis (CAD) systems have been developed to detect and classify such nodules in their early stages. Currently, CAD systems for pulmonary nodules comprise data acquisition, pre-processing, lung segmentation, nodule detection, false-positive reduction, segmentation, and classification. A number of review articles have considered various components of such systems, but this review focuses on segmentation and classification parts. Specifically, categorizing segmentation parts based on lung nodule type and network architectures, i.e., general neural network and multiview convolution neural network (CNN) architecture. Moreover, this work organizes related literature for classification of parts based on nodule or non-nodule and benign or malignant. The essential CT lung datasets and evaluation metrics used in the detection and diagnosis of lung nodules have been systematically summarized as well. Thus, this review provides a baseline understanding of the topic for interested readers.
Collapse
|
22
|
Milanese G, Sabia F, Ledda RE, Sestini S, Marchianò AV, Sverzellati N, Pastorino U. Volumetric Measurements in Lung Cancer Screening Reduces Unnecessary Low-Dose Computed Tomography Scans: Results from a Single-Center Prospective Trial on 4119 Subjects. Diagnostics (Basel) 2022; 12:diagnostics12020229. [PMID: 35204320 PMCID: PMC8871316 DOI: 10.3390/diagnostics12020229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 01/07/2022] [Accepted: 01/09/2022] [Indexed: 02/05/2023] Open
Abstract
This study aims to compare the low-dose computed tomography (LDCT) outcome and volume-doubling time (VDT) derived from the measured volume (MV) and estimated volume (EV) of pulmonary nodules (PNs) detected in a single-center lung cancer screening trial. MV, EV and VDT were obtained for prevalent pulmonary nodules detected at the baseline round of the bioMILD trial. The LDCT outcome (based on bioMILD thresholds) and VDT categories were simulated on PN- and screenee-based analyses. A weighted Cohen’s kappa test was used to assess the agreement between diagnostic categories as per MV and EV, and 1583 screenees displayed 2715 pulmonary nodules. In the PN-based analysis, 40.1% PNs were included in different LDCT categories when measured by MV or EV. The agreements between MV and EV were moderate (κ = 0.49) and fair (κ = 0.37) for the LDCT outcome and VDT categories, respectively. In the screenee-based analysis, 46% pulmonary nodules were included in different LDCT categories when measured by MV or EV. The agreements between MV and EV were moderate (κ = 0.52) and fair (κ = 0.34) for the LDCT outcome and VDT categories, respectively. Within a simulated lung cancer screening based on a recommendation by estimated volumetry, the number of LDCTs performed for the evaluation of pulmonary nodules was higher compared with in prospective volumetric management.
Collapse
Affiliation(s)
- Gianluca Milanese
- Radiological Sciences, Department of Medicine and Surgery (DiMeC), University Hospital of Parma, 43126 Parma, Italy; (G.M.); (R.E.L.); (N.S.)
| | - Federica Sabia
- Fondazione IRCCS Istituto Nazionale Tumori of Milan, 20133 Milan, Italy; (F.S.); (S.S.); (A.V.M.)
| | - Roberta Eufrasia Ledda
- Radiological Sciences, Department of Medicine and Surgery (DiMeC), University Hospital of Parma, 43126 Parma, Italy; (G.M.); (R.E.L.); (N.S.)
- Fondazione IRCCS Istituto Nazionale Tumori of Milan, 20133 Milan, Italy; (F.S.); (S.S.); (A.V.M.)
| | - Stefano Sestini
- Fondazione IRCCS Istituto Nazionale Tumori of Milan, 20133 Milan, Italy; (F.S.); (S.S.); (A.V.M.)
| | | | - Nicola Sverzellati
- Radiological Sciences, Department of Medicine and Surgery (DiMeC), University Hospital of Parma, 43126 Parma, Italy; (G.M.); (R.E.L.); (N.S.)
| | - Ugo Pastorino
- Fondazione IRCCS Istituto Nazionale Tumori of Milan, 20133 Milan, Italy; (F.S.); (S.S.); (A.V.M.)
- Correspondence:
| |
Collapse
|
23
|
Wang H, Li Y, Liu S, Yue X. Design Computer-Aided Diagnosis System Based on Chest CT Evaluation of Pulmonary Nodules. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:7729524. [PMID: 35047057 PMCID: PMC8763488 DOI: 10.1155/2022/7729524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Accepted: 12/08/2021] [Indexed: 11/17/2022]
Abstract
At present, the diagnosis and treatment of lung cancer have always been one of the research hotspots in the medical field. Early diagnosis and treatment of this disease are necessary means to improve the survival rate of lung cancer patients and reduce their mortality. The introduction of computer-aided diagnosis technology can easily, quickly, and accurately identify the lung nodule area as an imaging feature of early lung cancer for the clinical diagnosis of lung cancer and is helpful for the quantitative analysis of the characteristics of lung nodules and is useful for distinguishing benign and malignant lung nodules. Growth provides an objective diagnostic reference standard. This paper studies ITK and VTK toolkits and builds a system platform with MFC. By studying the process of doctors diagnosing lung nodules, the whole system is divided into seven modules: suspected lung shadow detection, image display and image annotation, and interaction. The system passes through the entire lung nodule auxiliary diagnosis process and obtains the number of nodules, the number of malignant nodules, and the number of false positives in each set of lung CT images to analyze the performance of the auxiliary diagnosis system. In this paper, a lung region segmentation method is proposed, which makes use of the obvious differences between the lung parenchyma and other human tissues connected with it, as well as the position relationship and shape characteristics of each human tissue in the image. Experiments are carried out to solve the problems of lung boundary, inaccurate segmentation of lung wall, and depression caused by noise and pleural nodule adhesion. Experiments show that there are 2316 CT images in 8 sets of images of different patients, and the number of nodules is 56. A total of 49 nodules were detected by the system, 7 were missed, and the detection rate was 87.5%. A total of 64 false-positive nodules were detected, with an average of 8 per set of images. This shows that the system is effective for CT images of different devices, pixel pitch, and slice pitch and has high sensitivity, which can provide doctors with good advice.
Collapse
Affiliation(s)
- Hui Wang
- Department of Radiology, The Second Affiliated Hospital of Harbin Medical University, 150086 Harbin, Heilongjiang, China
| | - Yanying Li
- Department of Radiology, The Second Affiliated Hospital of Harbin Medical University, 150086 Harbin, Heilongjiang, China
| | - Shanshan Liu
- Department of Radiology, Weifang Respiratory Disease Hospital, Weifang, 261041 Shandong, China
| | - Xianwen Yue
- Department of Radiology, Weifang Respiratory Disease Hospital, Weifang, 261041 Shandong, China
| |
Collapse
|
24
|
Balagurunathan Y, Beers A, McNitt-Gray M, Hadjiiski L, Napel S, Goldgof D, Perez G, Arbelaez P, Mehrtash A, Kapur T, Yang E, Moon JW, Bernardino G, Delgado-Gonzalo R, Farhangi MM, Amini AA, Ni R, Feng X, Bagari A, Vaidhya K, Veasey B, Safta W, Frigui H, Enguehard J, Gholipour A, Castillo LS, Daza LA, Pinsky P, Kalpathy-Cramer J, Farahani K. Lung Nodule Malignancy Prediction in Sequential CT Scans: Summary of ISBI 2018 Challenge. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3748-3761. [PMID: 34264825 PMCID: PMC9531053 DOI: 10.1109/tmi.2021.3097665] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Lung cancer is by far the leading cause of cancer death in the US. Recent studies have demonstrated the effectiveness of screening using low dose CT (LDCT) in reducing lung cancer related mortality. While lung nodules are detected with a high rate of sensitivity, this exam has a low specificity rate and it is still difficult to separate benign and malignant lesions. The ISBI 2018 Lung Nodule Malignancy Prediction Challenge, developed by a team from the Quantitative Imaging Network of the National Cancer Institute, was focused on the prediction of lung nodule malignancy from two sequential LDCT screening exams using automated (non-manual) algorithms. We curated a cohort of 100 subjects who participated in the National Lung Screening Trial and had established pathological diagnoses. Data from 30 subjects were randomly selected for training and the remaining was used for testing. Participants were evaluated based on the area under the receiver operating characteristic curve (AUC) of nodule-wise malignancy scores generated by their algorithms on the test set. The challenge had 17 participants, with 11 teams submitting reports with method description, mandated by the challenge rules. Participants used quantitative methods, resulting in a reporting test AUC ranging from 0.698 to 0.913. The top five contestants used deep learning approaches, reporting an AUC between 0.87 - 0.91. The team's predictor did not achieve significant differences from each other nor from a volume change estimate (p =.05 with Bonferroni-Holm's correction).
Collapse
Affiliation(s)
| | | | | | | | - Sandy Napel
- Dept. of Radiology, School of Medicine, Stanford University (SU), CA
| | | | - Gustavo Perez
- Biomedical computer vision lab (BCV), Universidad de los Andes, Colombia
| | - Pablo Arbelaez
- Biomedical computer vision lab (BCV), Universidad de los Andes, Colombia
| | - Alireza Mehrtash
- Robotics and Control Laboratory (RCL), Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC
- Surgical Planning Laboratory (SPL), Radiology Department, Brigham and Women’s Hospital, Boston, MA, 02130
| | - Tina Kapur
- Surgical Planning Laboratory (SPL), Radiology Department, Brigham and Women’s Hospital, Boston, MA, 02130
| | - Ehwa Yang
- Sungkyunkwan University School of Medicine, Seoul 06351, Korea
| | - Jung Won Moon
- Human Medical Imaging & Intervention Center, Seoul 06524, Korea
| | - Gabriel Bernardino
- Centre Suisse d’Électronique et de Microtechnique, Neuchâtel, Switzerland
| | | | - M. Mehdi Farhangi
- Medical Imaging Laboratory, University of Louisville, Louisville, KY. USA
- Computer Engineering and Computer Science, University of Louisville
| | - Amir A. Amini
- Medical Imaging Laboratory, University of Louisville, Louisville, KY. USA
- Electrical and Computer Engineering Department, University of Louisville, Louisville, KY. USA
| | | | - Xue Feng
- Spingbok Inc
- Department of Biomedical Engineering, University of Virginia, Charlottesville
| | | | | | - Benjamin Veasey
- Medical Imaging Laboratory, University of Louisville, Louisville, KY. USA
- Electrical and Computer Engineering Department, University of Louisville, Louisville, KY. USA
| | - Wiem Safta
- Computer Engineering and Computer Science, University of Louisville
| | - Hichem Frigui
- Computer Engineering and Computer Science, University of Louisville
| | - Joseph Enguehard
- Department of Radiology, Boston Children’s Hospital, and Harvard Medical School
| | - Ali Gholipour
- Department of Radiology, Boston Children’s Hospital, and Harvard Medical School
| | | | - Laura Alexandra Daza
- Department of Biomedical Engineering, Universidad de los Andes, Bogota, Colombia
| | - Paul Pinsky
- Divsion of Cancer Prevention, National Cancer Institute (NCI), Washington DC
| | | | - Keyvan Farahani
- Center for Biomedical Informatics and Information Technology, National Cancer Institute (NCI), Washington DC
| |
Collapse
|
25
|
Prospective Study of Low- and Standard-dose Chest CT for Pulmonary Nodule Detection: A Comparison of Image Quality, Size Measurements and Radiation Exposure. Curr Med Sci 2021; 41:966-973. [PMID: 34652628 DOI: 10.1007/s11596-021-2433-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Accepted: 12/20/2020] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To comprehensively and accurately analyze the out-performance of low-dose chest CT (LDCT) vs. standard-dose CT (SDCT). METHODS The image quality, size measurements and radiation exposure for LDCT and SDCT protocols were evaluated. A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols. Three experienced radiologists evaluated subjective image quality independently using a 5-point score system. Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics (size and volume). Radiation metrics and organ doses were analyzed using Radimetrics. RESULTS The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol. The sensitivity of LDCT for the detection of pulmonary nodules (n=650) was lower than that of SDCT (n=660). There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT (for BMI <22 kg/m2, 4.37 vs. 4.46 mm, and 43.66 vs. 46.36 mm3; for BMI ≥22 kg/m2, 4.3 vs. 4.41 mm, and 41.66 vs. 44.86 mm3) (P>0.05). The individualized volume CT dose index (CTDIvol), the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group (all P<0.0001). This was especially true for dose-sensitive organs such as the lung (for BMI <22 kg/m2, 2.62 vs. 12.54 mSV, and for BMI ≥22 kg/m2, 1.62 vs. 9.79 mSV) and the breast (for BMI <22 kg/m2, 2.52 vs. 10.93 mSV, and for BMI ≥22 kg/m2, 1.53 vs. 9.01 mSV) (P<0.0001). CONCLUSION These results suggest that with the increases in image noise, LDCT and SDCT exhibited a comparable image quality and sensitivity. The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol.
Collapse
|
26
|
Schreuder A, Jacobs C, Lessmann N, Broeders MJ, Silva M, Išgum I, de Jong PA, van den Heuvel MM, Sverzellati N, Prokop M, Pastorino U, Schaefer-Prokop CM, van Ginneken B. Scan-based competing death risk model for reevaluating lung cancer computed tomography screening eligibility. Eur Respir J 2021; 59:13993003.01613-2021. [PMID: 34649976 DOI: 10.1183/13993003.01613-2021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 09/17/2021] [Indexed: 11/05/2022]
Abstract
PURPOSE A baseline CT scan for lung cancer (LC) screening may reveal information indicating that certain LC screening participants can be screened less, and instead require dedicated early cardiac and respiratory clinical input. We aimed to develop and validate competing death (CD) risk models using CT information to identify participants with a low LC and a high CD risk. METHODS Participant demographics and quantitative CT measures of LC, cardiovascular disease, and chronic obstructive pulmonary disease were considered for deriving a logistic regression model for predicting five-year CD risk using a sample from the National Lung Screening Trial (n=15 000). Multicentric Italian Lung Detection data was used to perform external validation (n=2287). RESULTS Our final CD model outperformed an external pre-scan model (CDRAT) in both the derivation (Area under the curve=0.744 [95% confidence interval=0.727 to 0.761] and 0.677 [0.658 to 0.695], respectively) and validation cohorts (0.744 [0.652 to 0.835] and 0.725 [0.633 to 0.816], respectively). By also taking LC incidence risk into consideration, we suggested a risk threshold where a subgroup (6258/23 096, 27%) was identified with a number needed to screen to detect one LC of 216 (versus 23 in the remainder of the cohort) and ratio of 5.41 CDs per LC case (versus 0.88). The respective values in the validation cohort subgroup (774/2287, 34%) were 129 (versus 29) and 1.67 (versus 0.43). CONCLUSIONS Evaluating both LC and CD risks post-scan may improve the efficiency of LC screening and facilitate the initiation of multidisciplinary trajectories among certain participants.
Collapse
Affiliation(s)
- Anton Schreuder
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Colin Jacobs
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Nikolas Lessmann
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Mireille Jm Broeders
- Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen, the Netherlands.,Dutch Expert Centre for Screening, Nijmegen, the Netherlands
| | - Mario Silva
- Unit of Thoracic Surgery, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.,Section of Radiology, Unit of Surgical Sciences, Department of Medicine and Surgery (DiMeC), University of Parma, Parma, Italy
| | - Ivana Išgum
- Department of Biomedical Engineering and Physics, Amsterdam UMC - location AMC, Amsterdam.,Department of Radiology and Nuclear Medicine, Amsterdam UMC - location AMC, Amsterdam
| | - Pim A de Jong
- Department of Radiology, University Medical Center Utrecht, the Netherlands.,Utrecht University, the Netherlands
| | - Michel M van den Heuvel
- Department of Respiratory Diseases, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Nicola Sverzellati
- Department of Radiology and Nuclear Medicine, Amsterdam UMC - location AMC, Amsterdam
| | - Mathias Prokop
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Ugo Pastorino
- Department of Biomedical Engineering and Physics, Amsterdam UMC - location AMC, Amsterdam
| | - Cornelia M Schaefer-Prokop
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.,Department of Radiology, Meander Medisch Centrum, Amersfoort, the Netherlands
| | - Bram van Ginneken
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands.,Fraunhofer MEVIS, Bremen, Germany
| |
Collapse
|
27
|
Improved precision of noise estimation in CT with a volume-based approach. Eur Radiol Exp 2021; 5:39. [PMID: 34505172 PMCID: PMC8429536 DOI: 10.1186/s41747-021-00237-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 08/03/2021] [Indexed: 11/10/2022] Open
Abstract
Assessment of image noise is a relevant issue in computed tomography (CT). Noise is routinely measured by the standard deviation of density values (Hounsfield units, HU) within a circular region of interest (ROI). We explored the effect of a spherical volume of interest (VOI) on noise measurements. Forty-nine chronic obstructive pulmonary disease patients underwent CT with clinical protocol (regular dose [RD], volumetric CT dose index [CTDIvol] 3.04 mGy, 64-slice unit), and ultra-low dose (ULD) protocol (median CTDIvol 0.38 mGy, dual-source unit). Noise was measured in 27 1-cm2 ROIs and 27 0.75-cm3 VOIs inside the trachea. Median true noise was 21 HU (range 17-29) for RD-CT and 33 HU (26-39) for ULD-CT. The VOI approach resulted in a lower mean distance between limits of agreement compared to ROI: 5.9 versus 10.0 HU for RD-CT (-40%); 4.7 versus 9.9 HU for ULD-CT (-53%). Mean systematic bias barely changed: -1.6 versus -0.9HU for RD-CT; 0.0 to 0.4HU for ULD-CT. The average measurement time was 6.8 s (ROI) versus 9.7 (VOI), independent of dose level. For chest CT, measuring noise with a VOI-based instead of a ROI-based approach reduces variability by 40-53%, without a relevant effect on systematic bias and measurement time.
Collapse
|
28
|
Next Generation Sequencing Technology in Lung Cancer Diagnosis. BIOLOGY 2021; 10:biology10090864. [PMID: 34571741 PMCID: PMC8467994 DOI: 10.3390/biology10090864] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 08/26/2021] [Accepted: 08/31/2021] [Indexed: 12/29/2022]
Abstract
Simple Summary Lung cancer is still one of the most commonly diagnosed and deadliest cancers in the world. Its diagnosis at an early stage is highly necessary and will improve the standard of care of this disease. The aim of this article is to review the importance and applications of next generation sequencing in lung cancer diagnosis. As observed in many studies, next generation sequencing has been proven as a very helpful tool in the early detection of different types of cancers, including lung cancer, and has been used in the clinic, mainly due to its many advantages, such as low cost, speed, efficacy, low quantity usage of biological samples, and diversity. Abstract Lung cancer is still one of the most commonly diagnosed cancers, and one of the deadliest. The high death rate is mainly due to the late stage of diagnosis and low response rate to therapy. Previous and ongoing research studies have tried to discover new reliable and useful cbiomarkers for the diagnosis and prognosis of lung cancer. Next generation sequencing has become an essential tool in cancer diagnosis, prognosis, and evaluation of the treatment response. This article aims to review the leading research and clinical applications in lung cancer diagnosis using next generation sequencing. In this scope, we identified the most relevant articles that present the successful use of next generation sequencing in identifying biomarkers for early diagnosis correlated to lung cancer diagnosis and treatment. This technique can be used to evaluate a high number of biomarkers in a short period of time and from small biological samples, which makes NGS the preferred technique to develop clinical tests for personalized medicine using liquid biopsy, the new trend in oncology.
Collapse
|
29
|
Bredno J, Lipson J, Venn O, Aravanis AM, Jamshidi A. Clinical correlates of circulating cell-free DNA tumor fraction. PLoS One 2021; 16:e0256436. [PMID: 34432811 PMCID: PMC8386888 DOI: 10.1371/journal.pone.0256436] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 08/08/2021] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND Oncology applications of cell-free DNA analysis are often limited by the amount of circulating tumor DNA and the fraction of cell-free DNA derived from tumor cells in a blood sample. This circulating tumor fraction varies widely between individuals and cancer types. Clinical factors that influence tumor fraction have not been completely elucidated. METHODS AND FINDINGS Circulating tumor fraction was determined for breast, lung, and colorectal cancer participant samples in the first substudy of the Circulating Cell-free Genome Atlas study (CCGA; NCT02889978; multi-cancer early detection test development) and was related to tumor and patient characteristics. Linear models were created to determine the influence of tumor size combined with mitotic or metabolic activity (as tumor mitotic volume or excessive lesion glycolysis, respectively), histologic type, histologic grade, and lymph node status on tumor fraction. For breast and lung cancer, tumor mitotic volume and excessive lesion glycolysis (primary lesion volume scaled by percentage positive for Ki-67 or PET standardized uptake value minus 1.0, respectively) were the only statistically significant covariates. For colorectal cancer, the surface area of tumors invading beyond the subserosa was the only significant covariate. The models were validated with cases from the second CCGA substudy and show that these clinical correlates of circulating tumor fraction can predict and explain the performance of a multi-cancer early detection test. CONCLUSIONS Prognostic clinical variables, including mitotic or metabolic activity and depth of invasion, were identified as correlates of circulating tumor DNA by linear models that relate clinical covariates to tumor fraction. The identified correlates indicate that faster growing tumors have higher tumor fractions. Early cancer detection from assays that analyze cell-free DNA is determined by circulating tumor fraction. Results support that early detection is particularly sensitive for faster growing, aggressive tumors with high mortality, many of which have no available screening today.
Collapse
Affiliation(s)
- Joerg Bredno
- GRAIL, Inc., Menlo Park, California, United States of America
| | - Jafi Lipson
- GRAIL, Inc., Menlo Park, California, United States of America
| | - Oliver Venn
- GRAIL, Inc., Menlo Park, California, United States of America
| | | | - Arash Jamshidi
- GRAIL, Inc., Menlo Park, California, United States of America
| |
Collapse
|
30
|
Hunger T, Wanka-Pail E, Brix G, Griebel J. Lung Cancer Screening with Low-Dose CT in Smokers: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2021; 11:diagnostics11061040. [PMID: 34198856 PMCID: PMC8228723 DOI: 10.3390/diagnostics11061040] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/21/2021] [Accepted: 06/01/2021] [Indexed: 02/06/2023] Open
Abstract
Lung cancer continues to be one of the main causes of cancer death in Europe. Low-dose computed tomography (LDCT) has shown high potential for screening of lung cancer in smokers, most recently in two European trials. The aim of this review was to assess lung cancer screening of smokers by LDCT with respect to clinical effectiveness, radiological procedures, quality of life, and changes in smoking behavior. We searched electronic databases in April 2020 for publications of randomized controlled trials (RCT) reporting on lung cancer and overall mortality, lung cancer morbidity, and harms of LDCT screening. A meta-analysis was performed to estimate effects on mortality. Forty-three publications on 10 RCTs were included. The meta-analysis of eight studies showed a statistically significant relative reduction of lung cancer mortality of 12% in the screening group (risk ratio = 0.88; 95% CI: 0.79-0.97). Between 4% and 24% of screening-LDCT scans were classified as positive, and 84-96% of them turned out to be false positive. The risk of overdiagnosis was estimated between 19% and 69% of diagnosed lung cancers. Lung cancer screening can reduce disease-specific mortality in (former) smokers when stringent requirements and quality standards for performance are met.
Collapse
|
31
|
Yoshida Y, Yanagawa M, Hata A, Sato Y, Tsubamoto M, Doi S, Yamagata K, Miyata T, Kikuchi N, Tomiyama N. Quantitative volumetry of ground-glass nodules on high-spatial-resolution CT with 0.25-mm section thickness and 1024 matrix: Phantom and clinical studies. Eur J Radiol Open 2021; 8:100362. [PMID: 34141831 PMCID: PMC8184508 DOI: 10.1016/j.ejro.2021.100362] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/26/2021] [Accepted: 05/29/2021] [Indexed: 11/25/2022] Open
Abstract
High-spatial-resolution CT provided more accurate volume of a −800-HU nodule in a phantom than conventional settings. The maximum CT attenuation values were significantly higher in high-resolution setting than conventional setting. The high-resolution setting might allow earlier detection of solid components in GGNs during follow-up.
Objectives To compare high-resolution (HR) and conventional (C) settings of high-spatial-resolution computed tomography (CT) for software volumetry of ground-glass nodules (GGNs) in phantoms and patients. Methods We placed −800 and −630 HU spherical GGN-mimic nodules in 28 different positions in phantoms and scanned them individually. Additionally, 60 GGNs in 45 patients were assessed retrospectively. Images were reconstructed using the HR-setting (matrix size, 1024; slice thickness, 0.25 mm) and C-setting (matrix size, 512; slice thickness, 0.5 mm). We measured the GGN volume and mass using software. In the phantom study, the absolute percentage error (APE) was calculated as the absolute difference between Vernier caliper measurement-based and software-based volumes. In patients, we measured the density (mean, maximum, and minimum) and classified GGNs into low- and high-attenuation GGNs. Results In images of the −800 HU, but not −630 HU, phantom nodules, the volumes and masses differed significantly between the two settings (both p < 0.01). The APE was significantly lower in the HR-setting than in the C-setting (p < 0.01). In patients, volumes did not differ significantly between settings (p = 0.59). Although the mean attenuation was not significantly different, the maximum and minimum values were significantly increased and decreased, respectively, in the HR-setting (both p < 0.01). The volumes of both low-attenuation and high-attenuation GGNs were not significantly different between settings (p = 0.78 and 0.39, respectively). Conclusion The HR-setting might yield a more accurate volume for phantom GGN of −800 HU and influence the detection of maximum and minimum CT attenuation.
Collapse
Affiliation(s)
- Yuriko Yoshida
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Masahiro Yanagawa
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Akinori Hata
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Yukihisa Sato
- Department of Diagnostic Radiology, Suita Municipal Hospital, 5-7 Kishibeshinmachi Suita, Osaka 564-8567, Japan
| | - Mitsuko Tsubamoto
- Department of Diagnositic Radiology, Nishinomiya Municipal Central Hospital, 8-24 Hayashidacho, Nishinomiya, Hyogo, 663-8014, Japan
| | - Shuhei Doi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Kazuki Yamagata
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Tomo Miyata
- Department of Future Diagnostic Radiology, Osaka University Graduate School of Medicine 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Noriko Kikuchi
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| | - Noriyuki Tomiyama
- Department of Diagnostic and Interventional Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka Suita, Osaksa 565-0871, Japan
| |
Collapse
|
32
|
Schreuder A, Scholten ET, van Ginneken B, Jacobs C. Artificial intelligence for detection and characterization of pulmonary nodules in lung cancer CT screening: ready for practice? Transl Lung Cancer Res 2021; 10:2378-2388. [PMID: 34164285 PMCID: PMC8182724 DOI: 10.21037/tlcr-2020-lcs-06] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Lung cancer computed tomography (CT) screening trials using low-dose CT have repeatedly demonstrated a reduction in the number of lung cancer deaths in the screening group compared to a control group. With various countries currently considering the implementation of lung cancer screening, recurring discussion points are, among others, the potentially high false positive rates, cost-effectiveness, and the availability of radiologists for scan interpretation. Artificial intelligence (AI) has the potential to increase the efficiency of lung cancer screening. We discuss the performance levels of AI algorithms for various tasks related to the interpretation of lung screening CT scans, how they compare to human experts, and how AI and humans may complement each other. We discuss how AI may be used in the lung cancer CT screening workflow according to the current evidence and describe the additional research that will be required before AI can take a more prominent role in the analysis of lung screening CT scans.
Collapse
Affiliation(s)
- Anton Schreuder
- Department of Radiology, Nuclear Medicine, and Anatomy, Radboudumc, Nijmegen, The Netherlands
| | - Ernst T Scholten
- Department of Radiology, Nuclear Medicine, and Anatomy, Radboudumc, Nijmegen, The Netherlands
| | - Bram van Ginneken
- Department of Radiology, Nuclear Medicine, and Anatomy, Radboudumc, Nijmegen, The Netherlands.,Fraunhofer MEVIS, Bremen, Germany
| | - Colin Jacobs
- Department of Radiology, Nuclear Medicine, and Anatomy, Radboudumc, Nijmegen, The Netherlands
| |
Collapse
|
33
|
Fischer AM, Yacoub B, Savage RH, Martinez JD, Wichmann JL, Sahbaee P, Grbic S, Varga-Szemes A, Schoepf UJ. Machine Learning/Deep Neuronal Network: Routine Application in Chest Computed Tomography and Workflow Considerations. J Thorac Imaging 2021; 35 Suppl 1:S21-S27. [PMID: 32317574 DOI: 10.1097/rti.0000000000000498] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The constantly increasing number of computed tomography (CT) examinations poses major challenges for radiologists. In this article, the additional benefits and potential of an artificial intelligence (AI) analysis platform for chest CT examinations in routine clinical practice will be examined. Specific application examples include AI-based, fully automatic lung segmentation with emphysema quantification, aortic measurements, detection of pulmonary nodules, and bone mineral density measurement. This contribution aims to appraise this AI-based application for value-added diagnosis during routine chest CT examinations and explore future development perspectives.
Collapse
Affiliation(s)
- Andreas M Fischer
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - Basel Yacoub
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - Rock H Savage
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - John D Martinez
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | | | | | | | - Akos Varga-Szemes
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| | - U Joseph Schoepf
- Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC
| |
Collapse
|
34
|
Hong JH, Park S, Kim H, Goo JM, Park IK, Kang CH, Kim YT, Yoon SH. Volume and Mass Doubling Time of Lung Adenocarcinoma according to WHO Histologic Classification. Korean J Radiol 2020; 22:464-475. [PMID: 33169551 PMCID: PMC7909861 DOI: 10.3348/kjr.2020.0592] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 06/11/2020] [Accepted: 06/13/2020] [Indexed: 12/26/2022] Open
Abstract
Objective This study aimed to evaluate the tumor doubling time of invasive lung adenocarcinoma according to the International Association of the Study for Lung Cancer (IASLC)/American Thoracic Society (ATS)/European Respiratory Society (ERS) histologic classification. Materials and Methods Among the 2905 patients with surgically resected lung adenocarcinoma, we retrospectively included 172 patients (mean age, 65.6 ± 9.0 years) who had paired thin-section non-contrast chest computed tomography (CT) scans at least 84 days apart with the same CT parameters, along with 10 patients with squamous cell carcinoma (mean age, 70.9 ± 7.4 years) for comparison. Three-dimensional semiautomatic segmentation of nodules was performed to calculate the volume doubling time (VDT), mass doubling time (MDT), and specific growth rate (SGR) of volume and mass. Multivariate linear regression, one-way analysis of variance, and receiver operating characteristic curve analyses were performed. Results The median VDT and MDT of lung cancers were as follows: acinar, 603.2 and 639.5 days; lepidic, 1140.6 and 970.1 days; solid/micropapillary, 232.7 and 221.8 days; papillary, 599.0 and 624.3 days; invasive mucinous, 440.7 and 438.2 days; and squamous cell carcinoma, 149.1 and 146.1 days, respectively. The adjusted SGR of volume and mass of the solid-/micropapillary-predominant subtypes were significantly shorter than those of the acinar-, lepidic-, and papillary-predominant subtypes. The histologic subtype was independently associated with tumor doubling time. A VDT of 465.2 days and an MDT of 437.5 days yielded areas under the curve of 0.791 and 0.795, respectively, for distinguishing solid-/micropapillary-predominant subtypes from other subtypes of lung adenocarcinoma. Conclusion The tumor doubling time of invasive lung adenocarcinoma differed according to the IASCL/ATS/ERS histologic classification.
Collapse
Affiliation(s)
- Jung Hee Hong
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Samina Park
- Department of Thoracic and Cardiovascular Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Hyungjin Kim
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Jin Mo Goo
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea.,Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea
| | - In Kyu Park
- Department of Thoracic and Cardiovascular Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Chang Hyun Kang
- Department of Thoracic and Cardiovascular Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Young Tae Kim
- Department of Thoracic and Cardiovascular Surgery, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea
| | - Soon Ho Yoon
- Department of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea.
| |
Collapse
|
35
|
Rendle KA, Burnett-Hartman AN, Neslund-Dudas C, Greenlee RT, Honda S, Elston Lafata J, Marcus PM, Cooley ME, Vachani A, Meza R, Oshiro C, Simoff MJ, Schnall MD, Beaber EF, Doria-Rose VP, Doubeni CA, Ritzwoller DP. Evaluating Lung Cancer Screening Across Diverse Healthcare Systems: A Process Model from the Lung PROSPR Consortium. Cancer Prev Res (Phila) 2020; 13:129-136. [PMID: 31871221 PMCID: PMC7010351 DOI: 10.1158/1940-6207.capr-19-0378] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/18/2019] [Accepted: 12/18/2019] [Indexed: 02/07/2023]
Abstract
Numerous organizations, including the United States Preventive Services Task Force, recommend annual lung cancer screening (LCS) with low-dose CT for high risk adults who meet specific criteria. Despite recommendations and national coverage for screening eligible adults through the Centers for Medicare and Medicaid Services, LCS uptake in the United States remains low (<4%). In recognition of the need to improve and understand LCS across the population, as part of the larger Population-based Research to Optimize the Screening PRocess (PROSPR) consortium, the NCI (Bethesda, MD) funded the Lung PROSPR Research Consortium consisting of five diverse healthcare systems in Colorado, Hawaii, Michigan, Pennsylvania, and Wisconsin. Using various methods and data sources, the center aims to examine utilization and outcomes of LCS across diverse populations, and assess how variations in the implementation of LCS programs shape outcomes across the screening process. This commentary presents the PROSPR LCS process model, which outlines the interrelated steps needed to complete the screening process from risk assessment to treatment. In addition to guiding planned projects within the Lung PROSPR Research Consortium, this model provides insights on the complex steps needed to implement, evaluate, and improve LCS outcomes in community practice.
Collapse
Affiliation(s)
- Katharine A Rendle
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
| | | | | | | | - Stacey Honda
- Center for Health Research, Hawaii Permanente Medical Group, Kaiser Permanente Hawaii, Oahu, Hawaii
| | - Jennifer Elston Lafata
- Henry Ford Health System and Henry Ford Cancer Institute, Detroit, Michigan
- Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, North Carolina
| | - Pamela M Marcus
- Division of Cancer Control and Population Sciences, NCI, Bethesda, Maryland
| | | | - Anil Vachani
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
- Corporal Michael J. Crescenz VA Medical Center, Philadelphia, Pennsylvania
| | - Rafael Meza
- School of Public Health, University of Michigan, Ann Arbor, Michigan
| | - Caryn Oshiro
- Center for Health Research, Hawaii Permanente Medical Group, Kaiser Permanente Hawaii, Oahu, Hawaii
| | - Michael J Simoff
- Henry Ford Health System and Henry Ford Cancer Institute, Detroit, Michigan
| | - Mitchell D Schnall
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - V Paul Doria-Rose
- Division of Cancer Control and Population Sciences, NCI, Bethesda, Maryland
| | - Chyke A Doubeni
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Debra P Ritzwoller
- Institute for Health Research, Kaiser Permanente Colorado, Denver, Colorado
| |
Collapse
|
36
|
Toğaçar M, Ergen B, Cömert Z. Detection of lung cancer on chest CT images using minimum redundancy maximum relevance feature selection method with convolutional neural networks. Biocybern Biomed Eng 2020. [DOI: 10.1016/j.bbe.2019.11.004] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
37
|
Measurement Variability in Treatment Response Determination for Non-Small Cell Lung Cancer: Improvements Using Radiomics. J Thorac Imaging 2019; 34:103-115. [PMID: 30664063 DOI: 10.1097/rti.0000000000000390] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Multimodality imaging measurements of treatment response are critical for clinical practice, oncology trials, and the evaluation of new treatment modalities. The current standard for determining treatment response in non-small cell lung cancer (NSCLC) is based on tumor size using the RECIST criteria. Molecular targeted agents and immunotherapies often cause morphological change without reduction of tumor size. Therefore, it is difficult to evaluate therapeutic response by conventional methods. Radiomics is the study of cancer imaging features that are extracted using machine learning and other semantic features. This method can provide comprehensive information on tumor phenotypes and can be used to assess therapeutic response in this new age of immunotherapy. Delta radiomics, which evaluates the longitudinal changes in radiomics features, shows potential in gauging treatment response in NSCLC. It is well known that quantitative measurement methods may be subject to substantial variability due to differences in technical factors and require standardization. In this review, we describe measurement variability in the evaluation of NSCLC and the emerging role of radiomics.
Collapse
|
38
|
Yamamichi J, Kawaguchi Y, Otsuka T, Nakashita S, Mizobe H, Eguchi Y, Kimura S. Assessment of tumor volume and density as a measure of the response of advanced hepatocellular carcinoma to sorafenib: Application of automated measurements on computed tomography scans. JGH OPEN 2019; 4:145-152. [PMID: 32280757 PMCID: PMC7144795 DOI: 10.1002/jgh3.12230] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/18/2018] [Revised: 06/28/2019] [Accepted: 07/01/2019] [Indexed: 12/14/2022]
Abstract
Background and Aim To better predict patient survival, we used automated tumor volume and density measurements to make an objective radiological assessment of the response of advanced hepatocellular carcinoma (HCC) to treatment with sorafenib. Methods Patients treated with sorafenib were identified retrospectively. Those who were diagnosed with Child‐Pugh class A liver function, Barcelona‐Clinic Liver Cancer stage C, and Eastern Cooperative Oncology Group performance status grade 0/1 were enrolled (n = 22). Reviews of contrast‐enhanced computed tomography images were supported by the automated measurement of lesions using computer software. Treatment responses were assessed using volume and density criteria. Kaplan–Meier methods and multivariate Cox regression analysis were used to evaluate treatment responses and identify the most significant prognostic factors for overall survival (OS). Results After patients were dichotomized according to volume and density criteria, the median OS for those with an objective response (OR) (complete response + partial response) was 20.4 months and that for those with a non‐OR (stable disease + progressive disease) was 9.3 months (P = 0.009). The best multivariate regression model for survival identified volume and density criteria (OR or non‐OR) as a significant variable, along with baseline alpha‐fetoprotein levels (log‐rank test, P = 0.01). No other conventional criteria were identified as significant. Conclusions Tumor volume and density assessment using automated lesion measurements may be an objective method of evaluating responses of advanced HCC to treatment with sorafenib.
Collapse
Affiliation(s)
- Junta Yamamichi
- Medical Equipment Business Planning Department, Medical Systems Operations Canon Inc. Tokyo Japan
| | - Yasunori Kawaguchi
- Department of Hepatobiliary and Pancreatology Saga-ken Medical Centre Koseikan Saga Japan
| | - Taiga Otsuka
- Department of Oncology Saga-ken Medical Centre Koseikan Saga Japan
| | - Shunya Nakashita
- Department of Hepatobiliary and Pancreatology Saga-ken Medical Centre Koseikan Saga Japan
| | - Hideaki Mizobe
- Medical Equipment Business Planning Department, Medical Systems Operations Canon Inc. Tokyo Japan
| | - Yuichiro Eguchi
- Department of Internal Medicine, Faculty of Medicine Saga University Saga Japan
| | - Shinya Kimura
- Department of Internal Medicine, Faculty of Medicine Saga University Saga Japan
| |
Collapse
|
39
|
Screening for Early Lung Cancer, Chronic Obstructive Pulmonary Disease, and Cardiovascular Disease (the Big-3) Using Low-dose Chest Computed Tomography. J Thorac Imaging 2019; 34:160-169. [DOI: 10.1097/rti.0000000000000379] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
40
|
Marcus MW, Duffy SW, Devaraj A, Green BA, Oudkerk M, Baldwin D, Field J. Probability of cancer in lung nodules using sequential volumetric screening up to 12 months: the UKLS trial. Thorax 2019; 74:761-767. [PMID: 31028232 DOI: 10.1136/thoraxjnl-2018-212263] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 01/06/2019] [Accepted: 02/11/2019] [Indexed: 01/09/2023]
Abstract
BACKGROUND Estimation of the clinical probability of malignancy in patients with pulmonary nodules will facilitate early diagnosis, determine optimum patient management strategies and reduce overall costs. METHODS Data from the UK Lung Cancer Screening trial were analysed. Multivariable logistic regression models were used to identify independent predictors and to develop a parsimonious model to estimate the probability of lung cancer in lung nodules detected at baseline and at 3-month and 12-month repeat screening. RESULTS Of 1994 participants who underwent CT scan, 1013 participants had a total of 5063 lung nodules and 52 (2.6%) of the participants developed lung cancer during a median follow-up of 4 years. Covariates that predict lung cancer in our model included female gender, asthma, bronchitis, asbestos exposure, history of cancer, early and late onset of family history of lung cancer, smoking duration, FVC, nodule type (pure ground-glass and part-solid) and volume as measured by semiautomated volumetry. The final model incorporating all predictors had excellent discrimination: area under the receiver operating characteristic curve (AUC 0.885, 95% CI 0.880 to 0.889). Internal validation suggested that the model will discriminate well when applied to new data (optimism-corrected AUC 0.882, 95% CI 0.848 to 0.907). The risk model had a good calibration (goodness-of-fit χ[8] 8.13, p=0.42). CONCLUSIONS Our model may be used in estimating the probability of lung cancer in nodules detected at baseline and at 3 months and 12 months from baseline, allowing more efficient stratification of follow-up in population-based lung cancer screening programmes. TRIAL REGISTRATION NUMBER 78513845.
Collapse
Affiliation(s)
- Michael W Marcus
- Department of Molecular and Clinical Cancer Medicine, University of Liverpool, Liverpool, UK
| | - Stephen W Duffy
- Barts and London, Wolfson Institute of Preventive Medicine, London, UK
| | - Anand Devaraj
- Department of Radiology, Royal Brompton Hospital London, London, UK
| | - Beverley A Green
- Department of Molecular and Clinical Cancer Medicine, University of Liverpool, Liverpool, UK
| | - Matthijs Oudkerk
- Center for Medical Imaging (CMI), University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | | | - John Field
- Department of Molecular and Clinical Cancer Medicine, University of Liverpool, Liverpool, UK
| |
Collapse
|
41
|
Robins M, Solomon J, Hoye J, Smith T, Zheng Y, Ebner L, Choudhury KR, Samei E. Interchangeability between real and three-dimensional simulated lung tumors in computed tomography: an interalgorithm volumetry study. J Med Imaging (Bellingham) 2019; 5:035504. [PMID: 30840716 DOI: 10.1117/1.jmi.5.3.035504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2018] [Accepted: 08/27/2018] [Indexed: 12/17/2022] Open
Abstract
Using hybrid datasets consisting of patient-derived computed tomography (CT) images with digitally inserted computational tumors, we establish volumetric interchangeability between real and computational lung tumors in CT. Pathologically-confirmed malignancies from 30 thoracic patient cases from the RIDER database were modeled. Tumors were either isolated or attached to lung structures. Patient images were acquired on one of two CT scanner models (Lightspeed 16 or VCT; GE Healthcare) using standard chest protocol. Real tumors were segmented and used to inform the size and shape of simulated tumors. Simulated tumors developed in Duke Lesion Tool (Duke University) were inserted using a validated image-domain insertion program. Four readers performed volume measurements using three commercial segmentation tools. We compared the volume estimation performance of segmentation tools between real tumors in actual patient CT images and corresponding simulated tumors virtually inserted into the same patient images (i.e., hybrid datasets). Comparisons involved (1) direct assessment of measured volumes and the standard deviation between simulated and real tumors across readers and tools, respectively, (2) multivariate analysis, involving segmentation tools, readers, tumor shape, and attachment, and (3) effect of local tumor environment on volume measurement. Volume comparison showed consistent trends (9% volumetric difference) between real and simulated tumors across all segmentation tools, readers, shapes, and attachments. Across all cases, readers, and segmentation tools, an intraclass correlation coefficient = 0.99 indicates that simulated tumors correlated strongly with real tumors ( p = 0.95 ). In addition, the impact of the local tumor environment on tumor volume measurement was found to have a segmentation tool-related influence. Strong agreement between simulated tumors modeled in this study compared to their real counterparts suggests a high degree of similarity. This indicates that, volumetrically, simulated tumors embedded into patient CT data can serve as reasonable surrogates to real patient data.
Collapse
Affiliation(s)
- Marthony Robins
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Justin Solomon
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Jocelyn Hoye
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Taylor Smith
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Yuese Zheng
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Lukas Ebner
- Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States.,University of Bern, Department of Diagnostic, Interventional and Pediatric Radiology Inselspital, Bern, Switzerland
| | - Kingshuk Roy Choudhury
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| | - Ehsan Samei
- Carl E. Ravin Advanced Imaging Laboratories, Durham, North Carolina, United States.,Duke University, Medical Physics Graduate Program, Durham, North Carolina, United States.,Duke University Medical Center, Department of Radiology, Durham, North Carolina, United States
| |
Collapse
|
42
|
An Update on the European Lung Cancer Screening Trials and Comparison of Lung Cancer Screening Recommendations in Europe. J Thorac Imaging 2019; 34:65-71. [DOI: 10.1097/rti.0000000000000367] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
43
|
Loverdos K, Fotiadis A, Kontogianni C, Iliopoulou M, Gaga M. Lung nodules: A comprehensive review on current approach and management. Ann Thorac Med 2019; 14:226-238. [PMID: 31620206 PMCID: PMC6784443 DOI: 10.4103/atm.atm_110_19] [Citation(s) in RCA: 73] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
In daily clinical practice, radiologists and pulmonologists are faced with incidental radiographic findings of pulmonary nodules. Deciding how to manage these findings is very important as many of them may be benign and require no further action, but others may represent early disease and importantly early-stage lung cancer and require prompt diagnosis and definitive treatment. As the diagnosis of pulmonary nodules includes invasive procedures which can be relatively minimal, such as bronchoscopy or transthoracic aspiration or biopsy, but also more invasive procedures such as thoracic surgical biopsies, and as these procedures are linked to anxiety and to cost, it is important to have clearly defined algorithms for the description, management, and follow-up of these nodules. Clear algorithms for the imaging protocols and the management of positive findings should also exist in lung cancer screening programs, which are already established in the USA and which will hopefully be established worldwide. This article reviews current knowledge on nodule definition, diagnostic evaluation, and management based on literature data and mainly recent guidelines.
Collapse
Affiliation(s)
| | - Andreas Fotiadis
- 7th Respiratory Medicine Department, Athens Chest Hospital, Athens, Greece
| | | | | | - Mina Gaga
- 7th Respiratory Medicine Department, Athens Chest Hospital, Athens, Greece
| |
Collapse
|
44
|
Svahn TM, Sjöberg T, Ast JC. Dose estimation of ultra-low-dose chest CT to different sized adult patients. Eur Radiol 2018; 29:4315-4323. [PMID: 30560356 DOI: 10.1007/s00330-018-5849-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Revised: 09/14/2018] [Accepted: 10/22/2018] [Indexed: 01/28/2023]
Abstract
OBJECTIVES To evaluate the effect of patient size on radiation dose for standard CT (SD-CT), ultra-low-dose CT (ULD-CT) and two-view digital radiography (DR). METHODS Dosimeters were distributed within the lungs of chest phantoms representing males of 65 kg and 82 kg (body mass indices 23 and 29). In contrast to SD-CT and DR which include automatic exposure control (AEC), the ULD scan employs a fixed mAs value. The phantoms were exposed to SD, ULD and DR while recording lung doses. Projected dose data were calculated from the phantoms. The resulting exposure settings were used in Monte Carlo programs to determine the effective dose for a standard-sized (BMI 24.2) adult male (170 cm/70 kg) and female (160 cm/59 kg). Patients previously examined by both ULD- and SD-CT were identified to determine post hoc size-specific dose estimates (SSDEs). RESULTS ULD-CT dose was inversely related to patient size; average lung doses summarised in terms of patient size BMI23/29 are 5.2/8.1 (SD-CT), 0.56/0.35 (ULD-CT) and 0.05/0.13 mGy (DR), while the effective doses for these techniques on a standard-sized male were 2.9, 0.16 and 0.03 mSv and 2.3, 0.247 and 0.024 mSv for a standard-sized female respectively. SSDEs for 15 patients (averages: BMI 26, range 18-37) averaged 5.5 mGy (3.6-10) for SD-CT and 0.35 mGy (0.42-0.27) for ULD-CT. CONCLUSIONS The effective doses for a standard-sized male and female examined by ULD-CT are (respectively) ~ 6%/~ 11% of SD-CT and ~ 5/~ 10 times higher than DR. ULD-CT gave a lower radiation dosage to larger patients than DR. AEC is warranted in ULD-CT for improved dose consistency. KEY POINTS • For standard-sized patients, ULD-CT dose level is ~ 6%/~ 11% of SD-CT, and ~ 5/~ 10 times higher than DR. For larger patients, ULD-CT is currently being used clinically at lower dose levels than DR. • Using ULD-CT should greatly reduce the risk of late effects from ionising radiation. • AEC in ULD-CT is desirable for increased consistency in patient dose.
Collapse
Affiliation(s)
- Tony M Svahn
- Centre for Research and Development, Uppsala University/Region Gävleborg, 801 88, Gävle, Sweden.
| | - Tommy Sjöberg
- Department of Surgical Science, Uppsala University, 751 85, Uppsala, Sweden
| | - Jennifer C Ast
- Department of Organismal Biology, Uppsala University, 752 36, Uppsala, Sweden
| |
Collapse
|
45
|
Pennington TE, Thwin M, Sywak M, Delbridge L, Sidhu S. Sonographic Volumetric Assessment Is a More Accurate Measure Than Maximum Diameter Alone in Papillary Thyroid Cancer. J Endocr Soc 2018; 2:1284-1292. [PMID: 30430142 PMCID: PMC6223249 DOI: 10.1210/js.2018-00233] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 10/08/2018] [Indexed: 11/19/2022] Open
Abstract
Background Tumor size is an important prognostic factor in papillary thyroid cancer (PTC). Management guidelines, staging systems, and pathological definitions use maximum diameter (Dmax) as a surrogate marker of tumor size. However, PTC nodules are three-dimensional (3D) structures, with behavior reflective of tumor cell count, which is directly proportional to volume. We explored the relationship between sonographically determined Dmax, volume, and lymph node status (LNS) in a cohort of patients with PTC. Methods All patients treated for PTC between 2003 and 2015 in our institution who had sonographic 3D nodule measurements available were evaluated. We examined the relationship between diameter, volume, and LNS. Results A total of 159 nodules in 153 patients met the inclusion criteria. Mean nodule dimensions were 2.4 × 1.9 × 1.5 cm, giving “ideal” nodule dimensions of y × 0.78y × 0.62y, where y is the Dmax. Observed volumes differed from predicted nodule volumes by an average of 26.2%. For PTC ≤2 cm, the coefficient of variation was 26.7%. Dmax did not correlate with the presence of lymph node metastases (Pearson coefficient 0.08), whereas volume very weakly correlated with LNS (Pearson coefficient 0.22). However, both Dmax and volume correlated very strongly with the number of nodal metastases (Pearson coefficients 0.93 and 0.89, respectively). Conclusions PTC nodules demonstrated significant volume heterogeneity, rendering Dmax an inaccurate marker of true tumor size. Although there was little difference between Dmax and volume in predicting nodal status or nodal disease burden, we propose that a prospective, randomized trial might demonstrate a clear clinical advantage of 3D sonographic nodule measurement over Dmax alone.
Collapse
Affiliation(s)
- Thomas E Pennington
- University of Sydney Endocrine Surgical Unit, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - May Thwin
- University of Sydney Endocrine Surgical Unit, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - Mark Sywak
- University of Sydney Endocrine Surgical Unit, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - Leigh Delbridge
- University of Sydney Endocrine Surgical Unit, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| | - Stan Sidhu
- University of Sydney Endocrine Surgical Unit, Royal North Shore Hospital, St Leonards, New South Wales, Australia
| |
Collapse
|
46
|
Balagurunathan Y, Beers A, Kalpathy-Cramer J, McNitt-Gray M, Hadjiiski L, Zhao B, Zhu J, Yang H, Yip SSF, Aerts HJWL, Napel S, Cherezov D, Cha K, Chan HP, Flores C, Garcia A, Gillies R, Goldgof D. Semi-automated pulmonary nodule interval segmentation using the NLST data. Med Phys 2018; 45:1093-1107. [PMID: 29363773 DOI: 10.1002/mp.12766] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 01/04/2018] [Accepted: 01/04/2018] [Indexed: 01/26/2023] Open
Abstract
PURPOSE To study the variability in volume change estimates of pulmonary nodules due to segmentation approaches used across several algorithms and to evaluate these effects on the ability to predict nodule malignancy. METHODS We obtained 100 patient image datasets from the National Lung Screening Trial (NLST) that had a nodule detected on each of two consecutive low dose computed tomography (LDCT) scans, with an equal proportion of malignant and benign cases (50 malignant, 50 benign). Information about the nodule location for the cases was provided by a screen capture with a bounding box and its axial location was indicated. Five participating quantitative imaging network (QIN) institutions performed nodule segmentation using their preferred semi-automated algorithms with no manual correction; teams were allowed to provide additional manually corrected segmentations (analyzed separately). The teams were asked to provide segmentation masks for each nodule at both time points. From these masks, the volume was estimated for the nodule at each time point; the change in volume (absolute and percent change) across time points was estimated as well. We used the concordance correlation coefficient (CCC) to compare the similarity of computed nodule volumes (absolute and percent change) across algorithms. We used Logistic regression model on the change in volume (absolute change and percent change) of the nodules to predict the malignancy status, the area under the receiver operating characteristic curve (AUROC) and confidence intervals were reported. Because the size of nodules was expected to have a substantial effect on segmentation variability, analysis of change in volumes was stratified by lesion size, where lesions were grouped into those with a longest diameter of <8 mm and those with longest diameter ≥ 8 mm. RESULTS We find that segmentation of the nodules shows substantial variability across algorithms, with the CCC ranging from 0.56 to 0.95 for change in volume (percent change in volume range was [0.15 to 0.86]) across the nodules. When examining nodules based on their longest diameter, we find the CCC had higher values for large nodules with a range of [0.54 to 0.93] among the algorithms, while percent change in volume was [0.3 to 0.95]. Compared to that of smaller nodules which had a range of [-0.0038 to 0.69] and percent change in volume was [-0.039 to 0.92]. The malignancy prediction results showed fairly consistent results across the institutions, the AUC using change in volume ranged from 0.65 to 0.89 (Percent change in volume was 0.64 to 0.86) for entire nodule range. Prediction improves for large nodule range (≥ 8 mm) with AUC range 0.75 to 0.90 (percent change in volume was 0.74 to 0.92). Compared to smaller nodule range (<8 mm) with AUC range 0.57 to 0.78 (percent change in volume was 0.59 to 0.77). CONCLUSIONS We find there is a fairly high concordance in the size measurements for larger nodules (≥8 mm) than the lower sizes (<8 mm) across algorithms. We find the change in nodule volume (absolute and percent change) were consistent predictors of malignancy across institutions, despite using different segmentation algorithms. Using volume change estimates without corrections shows slightly lower predictability (for two teams).
Collapse
Affiliation(s)
| | - Andrew Beers
- Massachusetts General Hospital (MGH), Boston, MA, USA
| | | | | | | | | | | | - Hao Yang
- Columbia University (CUMU), New York, NY, USA
| | - Stephen S F Yip
- Radiation Oncology, Dana-Farber Cancer Institute (DFCC), Brigham and Women's Hospital (BWH) and Harvard Medical School (HMC), Boston, MA, USA.,Radiology, Dana-Farber Cancer Institute (DFCC) Brigham and Women's Hospital (BWH) and Harvard Medical School (HMC), Boston, MA, USA
| | - Hugo J W L Aerts
- Radiation Oncology, Dana-Farber Cancer Institute (DFCC), Brigham and Women's Hospital (BWH) and Harvard Medical School (HMC), Boston, MA, USA.,Radiology, Dana-Farber Cancer Institute (DFCC) Brigham and Women's Hospital (BWH) and Harvard Medical School (HMC), Boston, MA, USA
| | | | - Dmitrii Cherezov
- H.L.Moffitt Cancer Center (MCC), Tampa, FL, USA.,University of South Florida (USF), Tampa, FL, USA
| | - Kenny Cha
- University of Michigan (UMICH), Ann Arbor, MI, USA
| | | | - Carlos Flores
- University of California Los Angeles (UCLA), Los Angeles, CA, USA
| | | | | | - Dmitry Goldgof
- H.L.Moffitt Cancer Center (MCC), Tampa, FL, USA.,University of South Florida (USF), Tampa, FL, USA
| |
Collapse
|
47
|
Milanese G, Eberhard M, Martini K, Vittoria De Martini I, Frauenfelder T. Vessel suppressed chest Computed Tomography for semi-automated volumetric measurements of solid pulmonary nodules. Eur J Radiol 2018; 101:97-102. [PMID: 29571809 DOI: 10.1016/j.ejrad.2018.02.020] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 02/09/2018] [Accepted: 02/14/2018] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To evaluate whether vessel-suppressed computed tomography (VSCT) can be reliably used for semi-automated volumetric measurements of solid pulmonary nodules, as compared to standard CT (SCT) MATERIAL AND METHODS: Ninety-three SCT were elaborated by dedicated software (ClearRead CT, Riverain Technologies, Miamisburg, OH, USA), that allows subtracting vessels from lung parenchyma. Semi-automated volumetric measurements of 65 solid nodules were compared between SCT and VSCT. The measurements were repeated by two readers. For each solid nodule, volume measured on SCT by Reader 1 and Reader 2 was averaged and the average volume between readers acted as standard of reference value. Concordance between measurements was assessed using Lin's Concordance Correlation Coefficient (CCC). Limits of agreement (LoA) between readers and CT datasets were evaluated. RESULTS Standard of reference nodule volume ranged from 13 to 366 mm3. The mean overestimation between readers was 3 mm3 and 2.9 mm3 on SCT and VSCT, respectively. Semi-automated volumetric measurements on VSCT showed substantial agreement with the standard of reference (Lin's CCC = 0.990 for Reader 1; 0.985 for Reader 2). The upper and lower LoA between readers' measurements were (16.3, -22.4 mm3) and (15.5, -21.4 mm3) for SCT and VSCT, respectively. CONCLUSIONS VSCT datasets are feasible for the measurements of solid nodules, showing an almost perfect concordance between readers and with measurements on SCT.
Collapse
Affiliation(s)
- Gianluca Milanese
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistrasse 100, 8091 Zurich, Switzerland.
| | - Matthias Eberhard
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistrasse 100, 8091 Zurich, Switzerland.
| | - Katharina Martini
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistrasse 100, 8091 Zurich, Switzerland.
| | - Ilaria Vittoria De Martini
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistrasse 100, 8091 Zurich, Switzerland.
| | - Thomas Frauenfelder
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistrasse 100, 8091 Zurich, Switzerland.
| |
Collapse
|
48
|
Kakinuma R, Muramatsu Y, Yamamichi J, Gomi S, Oubel E, Moriyama N. Evaluation of the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules in CT lung cancer screening. J Thorac Dis 2018; 10:175-189. [PMID: 29600047 DOI: 10.21037/jtd.2017.11.142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background This study sought to evaluate the 95% limits of agreement of the volumes of 5-year clinically stable solid nodules for the development of a follow-up system for indeterminate solid nodules. Methods The volumes of 226 solid nodules that had been clinically stable for 5 years were measured in 186 patients (53 female never-smokers, 36 male never-smokers, 51 males with <30 pack-years, and 46 males with ≥30 pack-years) using a three-dimensional semiautomated method. Volume changes were evaluated using three methods: percent change, proportional change and growth rate. The 95% limits of agreement were evaluated using the Bland-Altman method. Results The 95% limits of agreement were as follows: range of percent change, from ±34.5% to ±37.8%; range of proportional change, from ±34.1% to ±36.8%; and range of growth rate, from ±39.2% to ±47.4%. Percent change-based, proportional change-based, and growth rate-based diagnoses of an increase or decrease in ten solid nodules were made at a mean of 302±402, 367±455, and 329±496 days, respectively, compared with a clinical diagnosis made at 809±616 days (P<0.05). Conclusions The 95% limits of agreement for volume change in 5-year stable solid nodules may enable the detection of an increase or decrease in the solid nodule at an earlier stage than that enabled by a clinical diagnosis, possibly contributing to the development of a follow-up system for reducing the number of additional Computed tomography (CT) scans performed during the follow-up period.
Collapse
Affiliation(s)
- Ryutaro Kakinuma
- Division of Cancer Screening, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan.,Cancer Screening Center, National Cancer Center, Tokyo, Japan.,Department of Pulmonology, Tokyo General Hospital, Tokyo, Japan
| | - Yukio Muramatsu
- Division of Cancer Screening, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan.,Department of Radiology, E-Medical Tokyo, Tokyo, Japan
| | - Junta Yamamichi
- Division of Cancer Screening, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan.,Global Healthcare IT Project, Medical Equipment Group, Canon Inc., Tokyo, Japan
| | - Shiho Gomi
- Division of Cancer Screening, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan.,Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan
| | - Estanislao Oubel
- MEDIAN Technologies, Valbonne Sophia Antipolis, Valbonne, France
| | - Noriyuki Moriyama
- Division of Cancer Screening, Research Center for Cancer Prevention and Screening, National Cancer Center, Tokyo, Japan.,Department of Radiology, Tokyo Midtown Medical Center, Tokyo, Japan
| |
Collapse
|
49
|
Heuvelmans MA, Walter JE, Vliegenthart R, van Ooijen PMA, De Bock GH, de Koning HJ, Oudkerk M. Disagreement of diameter and volume measurements for pulmonary nodule size estimation in CT lung cancer screening. Thorax 2017; 73:779-781. [DOI: 10.1136/thoraxjnl-2017-210770] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 10/03/2017] [Accepted: 10/09/2017] [Indexed: 12/26/2022]
Abstract
We studied 2240 indeterminate solid nodules (volume 50–500mm3) to determine the correlation of diameter and semi-automated volume measurements for pulmonary nodule size estimation. Intra-nodular diameter variation, defined as maximum minus minimum diameter through the nodule’s center, varied by 2.8 mm (median, IQR:2.2–3.7 mm), so above the 1.5 mm cutoff for nodule growth used in Lung CT Screening Reporting and Data System (Lung-RADS). Using mean or maximum axial diameter to assess nodule volume led to a substantial mean overestimation of nodule volume of 47.2% and 85.1%, respectively, compared to semi-automated volume. Thus, size of indeterminate nodules is poorly represented by diameter.Trial registration numberPre-results, ISRCTN63545820.
Collapse
|
50
|
Peikert T, Rajagopalan S, Bartholmai B, Maldonado F. While size matters-advanced "Radiomics" remain promising for the clinical management of ground glass opacities. J Thorac Dis 2017; 9:3568-3571. [PMID: 29268343 DOI: 10.21037/jtd.2017.09.56] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Tobias Peikert
- Division of Pulmonary and Critical Care Medicine, Mayo Clinic, Rochester, MN, USA
| | | | | | - Fabien Maldonado
- Division of Allergy, Pulmonary and Critical Care Medicine, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|