1
|
Stoops TK, Layuno-Matos JG, Simon P, Gustke KA, Bernasek TL. Metal-on-Metal Total Hip Arthroplasties: Why Do They Fail? Arthroplast Today 2025; 33:101662. [PMID: 40207181 PMCID: PMC11978342 DOI: 10.1016/j.artd.2025.101662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2024] [Revised: 01/13/2025] [Accepted: 02/10/2025] [Indexed: 04/11/2025] Open
Abstract
Background Metal sensitivity reaction is a major concern in painful failed metal-on-metal (MoM) total hip arthroplasty (THA), but it may not be the dominant failure mode. We investigated revised MoM THAs for failure etiologies, operative indications, and clinical outcomes. Methods Ninety consecutive revised MoM THAs were reviewed. Preoperative evaluation included inflammatory markers, metal ion levels, radiographs, metal artifact reduction sequence magnetic resonance imaging, synovial fluid analysis, and operative histopathology. Outcome measures included advanced imaging and laboratory findings, revision etiology, and clinical outcomes. Results Metal sensitivity reactions (MSRs) accounted for 36% of MoM failures, with 64% of MoM THA being revised for non-MSR-related etiologies. Failure etiologies not related to MoM bearing articulation included prosthetic joint infection (14%), aseptic loosening (13%), isolated abductor failure (7%), periprosthetic fracture (3%), recurrent dislocation (3%), symptomatic heterotopic ossification (3%), mechanical failure (1%), and angiosarcoma (1%). Additionally, 18% of patients had painful MoM THA with no identifiable failure etiology; of these patients, 69% had continued pain following revision. Patients with large periarticular fluid collections had an odds ratio of 19.2 (P =< 0.0001) of having MSR. Cobalt (Co) levels were statistically higher in patients with MSR compared to non-MSR-related failures (P = .034). Chromium (Cr) ion levels and the Co/Cr ratio did not predict MSR. Conclusions The majority of revised MoM THAs did not have MSR. Large periarticular fluid collections and elevated Co levels were highly predictive of MSR. Painful MoM THA without an identifiable failure etiology resulted in a high incidence of persistent pain following revision.
Collapse
Affiliation(s)
- T. Kyle Stoops
- Indiana Joint Replacement Institute, Noblesville, IN, United States
| | - Josué G. Layuno-Matos
- Foundation for Orthopaedic Research and Education, Temple Terrace, FL, United States
| | - Peter Simon
- Foundation for Orthopaedic Research and Education, Temple Terrace, FL, United States
| | | | - Thomas L. Bernasek
- Foundation for Orthopaedic Research and Education, Temple Terrace, FL, United States
- Florida Orthopaedic Institute, Temple Terrace, FL, United States
- Tampa General Hospital, Department of Orthopaedic Surgery, 1 Tampa General Circle, Tampa, FL, United States
| |
Collapse
|
2
|
Chotai N, Kaila R, Wilson H, Pradhan R, Asopa V, Grammatopoulos G, Andrade AJ. A case series of modular hip hemiarthroplasties employing a metal-on-metal taper-trunnion junction : are they a source of metal particle release? Bone Joint J 2025; 107-B:479-485. [PMID: 40164182 DOI: 10.1302/0301-620x.107b4.bjj-2024-0576.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/02/2025]
Abstract
Aims Hip hemiarthroplasty is a common procedure in the treatment of intracapsular displaced femoral neck fractures. Modular hemiarthroplasties have a separate stem, neck, and head component which gives the surgeon more combinations to try and accurately recreate the patient's original hip geometry. Despite regular use, little is known regarding susceptibility to metal-on-metal debris wear in this specific situation. Methods This single-centre, two-year prospective cohort study aimed to characterize in vivo wear and associated adverse reaction to metal debris (ARMD) in an uncemented CORAIL stem and Cathcart modular head hip hemiarthroplasty. The mean patient age was 80.5 years (62 to 96) and mean follow-up 2.2 years (1.0 to 4.6). Overall, 54 patients had a clinical, radiological, and serum metal ion (chromium (Cr) and cobalt (Co)) assessment. At follow-up radiological evidence of acetabular erosion was graded (0 to 3: normal to protrusio). Metal ion levels were considered high if ≥ 7 ppb as per current Medicines and Healthcare products Regulatory Agency guidelines. Results Final Cr and Co levels in ppb were 0.26 (IQR 1.33; 95% CI 0.67 to 5.16) and 0.68 (IQR 2.52; 95% CI 1.25 to 3.30), respectively. The mean one-year Oxford Hip Score was 35 (SD 10). Acetabular erosion was detected in 27 patients (50%). All eight patients (14.8%) with high metal ion levels had associated acetabular erosion, of which four (50%) had an ARMD lesion. Patients with high metal ion levels had a similar head size with the same taper size, similar OHS, and similar pre-fracture mobility to those with low metal ion levels. Conclusion Modular hip hemiarthroplasty patients may be susceptible to metallosis and ARMD despite being less active individuals than those who receive a total hip arthroplasty. Acetabular erosion was associated with a 2.5-times increased risk of raised metal ion levels but cause and effect have not been established.
Collapse
Affiliation(s)
- Neil Chotai
- Royal Berkshire NHS Foundation Trust, Reading, UK
| | - Rajiv Kaila
- Royal Berkshire NHS Foundation Trust, Reading, UK
| | | | | | - Vipin Asopa
- Royal Berkshire NHS Foundation Trust, Reading, UK
| | - George Grammatopoulos
- University of Ottawa Orthopaedic Surgery, The Ottawa Hospital - General Campus, Ottawa, Canada
| | - A J Andrade
- Royal Berkshire NHS Foundation Trust, Reading, UK
| |
Collapse
|
3
|
Reito A, Lainiala O, Berryman F, Dunlop DJ, Eskelinen A, Matharu GS. Long-term changes in blood metal ion levels in patients with hip resurfacing implants: implications for patient surveillance after 10 years follow-up. Hip Int 2023; 33:864-871. [PMID: 35848136 DOI: 10.1177/11207000221104396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Studies investigating changes in blood metal ion levels during the second decade of the implant lifetime in MoM hip resurfacing patients are scarce. METHODS Patients implanted with either Birmingham Hip Resurfacing (BHR) or Articular Surface Replacement (ASR) hip resurfacings with >10 years follow-up and repeated blood metal ion measurements were identified at 2 large specialist European arthroplasty centres. After excluding patients with initial metal ion levels >7 ppb, the proportion of patients with an increase in blood metal ion levels above previously validated implant-specific thresholds (cobalt 2.15 ppb for unilateral implants, cobalt or chromium 5.5 ppb for bilateral) was assessed. RESULTS We included 2743 blood metal ion measurements from 457 BHR patients (555 hips) and 216 ASR patients (263 hips). Of patients with initial metal ion levels below implant specific thresholds, increases in cobalt or chromium level, respectively, to above these thresholds during the second decade were seen as follows: unilateral BHR (cobalt = 15.6%), unilateral ASR (cobalt = 13.8%), bilateral BHR (cobalt = 8.2%, chromium = 11.8%), bilateral ASR (cobalt = 8.5%, chromium = 4.3%). Measurement-to-measurement changes exceeding +2.15 ppb or +5.5 ppb were, however, uncommon during the second decade. Subgroup results with small diameter (<50 mm) implants were similar. CONCLUSIONS We recommend less frequent blood metal ion measurements are needed (every 3 to 5 years) for hip resurfacing patients if initial values were below 7ppb.
Collapse
Affiliation(s)
- Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland and Faculty of Medicine and Health Technologies, University of Tampere, Tampere, Finland
| | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Tampere, Finland and Faculty of Medicine and Health Technologies, University of Tampere, Tampere, Finland
| | | | | | - Antti Eskelinen
- Coxa Hospital for Joint Replacement, Tampere, Finland and Faculty of Medicine and Health Technologies, University of Tampere, Tampere, Finland
| | - Gulraj S Matharu
- The Royal Orthopaedic Hospital, Birmingham, UK
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Westbury-on-Trym, Bristol, BS10 5NB, UK
| |
Collapse
|
4
|
Oxblom A, Hedlund H, Itayem R, Felländer-Tsai L, Vidgren M, Rolfson O, Brismar H. Careful patient selection together with optimal implant positioning may reduce but does not eliminate the risk of elevated serum cobalt and chrome levels following metal-on-metal hip resurfacing. Hip Int 2023; 33:872-879. [PMID: 36314413 PMCID: PMC10486161 DOI: 10.1177/11207000221124302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 07/31/2022] [Indexed: 02/04/2023]
Abstract
BACKGROUND Elevated serum chrome (sCr) and cobalt (sCo) concentrations are associated with local tissue adverse reactions to metal debris following metal-on-metal hip resurfacing (MoM-HR). Serum metal ions <2 µg/l are probably of little clinical relevance and a pragmatic "safe" threshold <5 µg/l has been suggested.The primary aim of this study was to evaluate if a careful selection of patients combined with optimal implant positioning could eliminate cases with "unsafe" serum metal ion levels. A secondary aim was to study the association between different risk factors and having Co and/or Cr levels >5 µg/l. PATIENTS AND METHODS This is a retrospective, single-institution cohort study of 410 consecutive patients operated on with a Birmingham Hip Resurfacing (BHR) implant between 2001 and 2014. 288 of these had a unilateral MoM-HR, pelvic and true lateral radiographs, and a related sCo and sCr sample, and were included in the final analysis. They were allocated to either a presumed "optimal group" consisting of only men aged <60 years old, with femoral head component >48 mm diameter, and with a cup positioned within Lewinnek's safe zones, or a "suboptimal group" consisting of the remaining patients. Fisher's exact test and multiple logistic regression analyses were performed. RESULTS In the optimal group 48% (47/97) had serum metal ions >2 µg/l and 8% (8/97) >5 µg/l compared to 61% (116/191) and 18% (34/191) in the suboptimal group, p = 0.059 and p = 0.034 respectively. Acetabular cups with an anteversion <5 degrees had the highest odds ratio, 6.5 (95% CI, 3.0-14.3), of having sCo and sCr concentrations exceeding 5 µg/l. CONCLUSIONS A well oriented BHR acetabular component in a presumably "optimal" patient reduces the risk of having elevated serum metal ions but does not eliminate it. Insufficient cup anteversion seems to be the strongest associated factor of elevated serum metals.
Collapse
Affiliation(s)
- Alexander Oxblom
- Division of Orthopaedics and Biotechnology, CLINTEC, Karolinska Institute, Stockholm, Sweden
- Department of Orthopaedics, VO KOU, Sodertalje Hospital, Sodertalje, Sweden
| | - Håkan Hedlund
- Division of Orthopaedics and Biotechnology, CLINTEC, Karolinska Institute, Stockholm, Sweden
- Department of Orthopaedics, Visby Hospital, Visby, Sweden
| | - Raed Itayem
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy University of Gothenburg, Sweden
| | - Li Felländer-Tsai
- Division of Orthopaedics and Biotechnology, CLINTEC, Karolinska Institute, Stockholm, Sweden
- Department of Reconstructive Orthopaedics, Karolinska University Hospital, Stockholm, Sweden
| | - Mathias Vidgren
- Division of Orthopaedics and Biotechnology, CLINTEC, Karolinska Institute, Stockholm, Sweden
| | - Ola Rolfson
- Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy University of Gothenburg, Sweden
| | - Harald Brismar
- Division of Orthopaedics and Biotechnology, CLINTEC, Karolinska Institute, Stockholm, Sweden
- Department of Reconstructive Orthopaedics, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
5
|
Nandra RS, Ahmed U, Berryman F, Brash L, Dunlop DJ, Matharu GS. How much does a Medical and Healthcare Products Regulatory Agency medical device alert for metal-on-metal hip arthroplasty patients really cost? Hip Int 2022; 32:493-500. [PMID: 33445979 PMCID: PMC9203671 DOI: 10.1177/1120700020983297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Many worldwide regulatory authorities recommend regular surveillance of metal-on-metal hip arthroplasty patients given high failure rates. However, concerns have been raised about whether such regular surveillance, which includes asymptomatic patients, is evidence-based and cost-effective. We determined: (1) the cost of implementing the 2015 MHRA surveillance in "at-risk" Birmingham Hip Resurfacing (BHR) patients; and (2) how many asymptomatic hips with adverse reactions to metal debris (ARMD) would have been missed without patient recall. METHODS All BHR patients eligible for the 2015 MHRA recall (all females, and males with head sizes ⩽46 mm, regardless of symptoms) at one centre were invited for review (hips = 707; patients = 593). All patients were investigated (Oxford Hip Score, radiographs, blood metal ions, and targeted cross-sectional imaging) and managed accordingly. Surveillance costs were calculated using finance department data. RESULTS The surveillance cost £105,921.79 (range £147.76-£257.50/patient). Radiographs (£39,598) and nurse practitioner time/assistance (£23,618) accounted for 60% of overall costs. 31 hips had ARMD on imaging (12 revised; 19 under surveillance). All revisions were symptomatic. 7 hips with ARMD under surveillance were asymptomatic and remain under regular review. The number needed to treat to avoid missing one asymptomatic ARMD case was 101 patients, representing a cost of £18,041 to avoid one asymptomatic case. CONCLUSIONS Implementing MHRA surveillance for "at-risk" BHR patients was extremely costly. The risk of asymptomatic ARMD was low with the BHR (1%), suggesting recommended follow-up in asymptomatic patients is not cost efficient. This raises concerns about the increasingly intensive surveillance recommended in the 2017 MHRA guidance for metal-on-metal hip patients.
Collapse
Affiliation(s)
| | - Usman Ahmed
- The Royal Orthopaedic Hospital, Birmingham, UK
| | | | | | | | - Gulraj S Matharu
- The Royal Orthopaedic Hospital, Birmingham, UK,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, Southmead Hospital, Bristol, UK,Gulraj S Matharu, Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, 1st Floor Learning & Research Building, Southmead Hospital, Bristol, BS10 5NB, UK.
| |
Collapse
|
6
|
Perino G, De Martino I, Zhang L, Xia Z, Gallo J, Natu S, Langton D, Huber M, Rakow A, Schoon J, Gomez-Barrena E, Krenn V. The contribution of the histopathological examination to the diagnosis of adverse local tissue reactions in arthroplasty. EFORT Open Rev 2021; 6:399-419. [PMID: 34267931 PMCID: PMC8246109 DOI: 10.1302/2058-5241.6.210013] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
The histopathological examination of the periprosthetic soft tissue and bone has contributed to the identification and description of the morphological features of adverse local tissue reactions (ALTR)/adverse reactions to metallic debris (ARMD). The need of a uniform vocabulary for all disciplines involved in the diagnosis and management of ALTR/ARMD and of clarification of the parameters used in the semi-quantitative scoring systems for their classification has been considered a pre-requisite for a meaningful interdisciplinary evaluation. This review of key terms used for ALTR/ARMD has resulted in the following outcomes: (a) pseudotumor is a descriptive term for ALTR/ARMD, classifiable in two main types according to its cellular composition defining its clinical course; (b) the substitution of the term metallosis with presence of metallic wear debris, since it cannot be used as a category of implant failure or histological diagnosis; (c) the term aseptic lymphocytic-dominated vasculitis- associated lesion (ALVAL) should be replaced due to the absence of a vasculitis with ALLTR/ALRMD for lymphocytic-predominant and AMLTR/AMRMD for macrophage-predominant reaction. This review of the histopathological classifications of ALTR/ARMD has resulted in the following outcomes: (a) distinction between cell death and tissue necrosis; (b) the association of corrosion metallic debris with adverse local lymphocytic reaction and tissue necrosis; (c) the importance of cell and particle debris for the viscosity and density of the lubricating synovial fluid; (d) a consensus classification of lymphocytic infiltrate in soft tissue and bone marrow; (e) evaluation of the macrophage infiltrate in soft tissues and bone marrow; (f) classification of macrophage induced osteolysis/aseptic loosening as a delayed type of ALTR/ARMD; (g) macrophage motility and migration as possible driving factor for osteolysis; (h) usefulness of the histopathological examination for the natural history of the adverse reactions, radiological correlation, post-marketing surveillance, and implant registries. The review of key terms used for the description and histopathological classification of ALTR/ARMD has resulted in a comprehensive, new standard for all disciplines involved in their diagnosis, clinical management, and long-term clinical follow-up.
Cite this article: EFORT Open Rev 2021;6:399-419. DOI: 10.1302/2058-5241.6.210013
Collapse
Affiliation(s)
- Giorgio Perino
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| | - Lingxin Zhang
- Department of Pathology and Laboratory Medicine, Sinai Health System, Toronto, Canada
| | - Zhidao Xia
- Centre for Nanohealth, Swansea University Medical School, Singleton Park, Swansea, UK
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, University Hospital, Palacky University Olomouc, Czech Republic
| | - Shonali Natu
- Department of Pathology, University Hospital of North Tees and Hartlepool NHS Foundation Trust, Stockton-on-Tees, UK
| | - David Langton
- Orthopaedic Department, Freeman Hospital, Newcastle upon Tyne, UK
| | - Monika Huber
- Pathologisch-bakteriologisches Institut, Otto Wagner Spital, Wien, Austria
| | - Anastasia Rakow
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Janosch Schoon
- Department of Orthopedics and Orthopedic Surgery, University Medicine Greifswald, Greifswald, Germany
| | - Enrique Gomez-Barrena
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario La Paz-IdiPAZ, Universidad Autónoma de Madrid, Madrid, Spain
| | - Veit Krenn
- MVZ-Zentrum für Histologie, Zytologie und Molekulare Diagnostik-GmbH, Trier, Germany
| |
Collapse
|
7
|
Whole blood chromium concentration is very rarely elevated independently of whole blood cobalt. Sci Rep 2021; 11:12352. [PMID: 34117287 PMCID: PMC8196186 DOI: 10.1038/s41598-021-91512-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Accepted: 05/19/2021] [Indexed: 11/21/2022] Open
Abstract
Due to the risk of adverse reactions to metal debris resulting from increased wear of the arthroplasty more than one million metal-on-metal (MoM) hip replacements worldwide are in active follow-up. Follow-up usually includes measurement of both whole blood cobalt (Co) and chromium (Cr) concentrations. Our experience is that Cr is seldom independently elevated. We wanted to ascertain whether blood Cr measurements could be omitted from follow-up protocols without lowering the quality of follow-up. We identified 8438 whole blood Co and Cr measurements performed without or prior to revision surgery. When the cut-off levels 5 µg/L and 7 µg/L were used, Cr was independently elevated in only 0.5% (95% confidence interval, CI, 0.3 to 0.6) and 0.2% (CI 0.1 to 0.3) of the measurements. The models with continuous variables showed that the higher the blood metal concentrations are the lower the percentage of measurements with Cr higher than Co. Our results suggest that whole blood Cr is very rarely independently elevated and therefore the authorities should consider omitting Cr measurements from their screening guidelines of MoM hip replacements. We believe this change in practice would simplify follow-up and lead to cost savings without decreasing the quality of follow-up.
Collapse
|
8
|
Jenkinson MRJ, Meek RMD, Tate R, MacMillan S, Grant MH, Currie S. Cobalt-induced cardiomyopathy - do circulating cobalt levels matter? Bone Joint Res 2021; 10:340-347. [PMID: 34053230 PMCID: PMC8242681 DOI: 10.1302/2046-3758.106.bjr-2020-0414.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347.
Collapse
Affiliation(s)
| | | | - Rothwell Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | - M Helen Grant
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
9
|
Koper MC, Hesseling B, Tuinebreijer WE, van der Linden H, Mathijssen NMC. Safe Upper Limits of Serum Cobalt and Chromium Levels for a Metal-on-Metal Total Hip Bearing: A 10-Year Follow-Up Study. J Arthroplasty 2021; 36:2080-2086. [PMID: 33612330 DOI: 10.1016/j.arth.2021.01.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Revised: 01/02/2021] [Accepted: 01/11/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Long-term survival of metal-on-metal (MoM) prostheses and the development of adverse reaction to metal debris (ARMD) around these bearings are still unclear. Serum levels of cobalt (Co) and chromium (Cr) are used as a screening tool to anticipate failure in MoM bearings and detect ARMD. METHODS One hundred sixty primary large head MoM prostheses were followed up for 10 years. To estimate the revision risk, the cumulative incidence function (CIF) was used. Subdistribution hazard modeling was used to investigate the associations between cumulative incidence of revision for ARMD and Co levels, Cr levels, gender, age, head size, and cup inclination. Furthermore, the safe upper limits (SULs) for Co and Cr were determined. RESULTS Univariate analyses showed an increased risk in revision for ARMD in females (subdistribution hazard ratio [sdHR] 3.43, 95% confidence interval [CI] 1.01-11.7, P = .049) and cup inclination angles over 45° (sdHR 4.70, 95% CI 1.63-13.58, P = .004). In addition, a higher last measured Co level (sdHR 1.05, 95% CI 1.03-1.07, P < .001) and last measured Cr level (sdHR 1.21, 95% CI 1.14-1.29, P < .001) were associated with a higher probability of revision for ARMD. We determined our bearing-specific SULs at 4.1 parts per billion (ppb) and 4.2 ppb for Co and Cr, respectively. CONCLUSION Guidelines regarding follow-up and surveillance should include a complete clinical assessment with bearing-specific SULs of serum metal ion levels. For the M2a-Magnum MoM bearing we advise an SUL for Co and Cr levels of 4.1 and 4.2 ppb, respectively.
Collapse
Affiliation(s)
- Maarten C Koper
- Department of Orthopedics, Reinier de Graaf Hospital, Delft, The Netherlands
| | - Brechtje Hesseling
- Department of Orthopedics, Reinier de Graaf Hospital, Delft, The Netherlands
| | - Wim E Tuinebreijer
- Department of Surgery, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Hans van der Linden
- Department of Orthopedics, Reinier de Graaf Hospital, Delft, The Netherlands
| | - Nina M C Mathijssen
- Department of Orthopedics, Reinier de Graaf Hospital, Delft, The Netherlands
| |
Collapse
|
10
|
Galea VP, Rojanasopondist P, Matuszak SJ, Connelly JW, Ray GS, Madanat R, Muratoglu O, Malchau H. Current evidence from a worldwide, multicentre, follow-up study of the recalled Articular Surface Replacement Hip System. Hip Int 2021; 31:378-387. [PMID: 31746236 DOI: 10.1177/1120700019887726] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Our first aim was to report the longitudinal clinical performance of patients treated with the ASR Hip System, a metal-on-metal (MoM) device, in their mid- to late-term follow-up. Secondly, we sought to report on the reasons and risk factors for mid- to late-term implant failure. METHODS A total of 1721 ASR patients (1933 hips) from 16 centres in 6 countries were enrolled to a prospective, post-recall study. The average time to enrollment was 7.4 years from index surgery. Data from 3 follow-up visits over 2 years were analysed. Implant performance, based on ion levels and PROMs, was determined at each clinical visit. RESULTS The proportion of those exhibiting good performance decreased over time for hip resurfacing (ASR HRA) and total hip arthroplasty (ASR XL) patients. ASR XL patients were likely to exhibit longitudinal blood metal ion increases regardless of symptom state. ASR HRA patients were more likely to present with and maintain good performance over time, especially males with high general health indicators. 6% of ASR HRA and 14% of ASR XL patients were revised throughout the study period. DISCUSSION ASR XL THA patients are likely to exhibit blood metal ion increases without accompanying changes in symptom state, and therefore should be followed with annual blood tests at minimum. While appropriately selected ASR HRA patients were the most likely to exhibit low blood metal ion levels and report no symptoms, we recommend vigilant follow-up of all ASR patients to ensure that worsening clinical outcomes and asymptomatic soft tissue damage are not missed.
Collapse
Affiliation(s)
- Vincent P Galea
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | | | - Sean J Matuszak
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - James W Connelly
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Gabrielle S Ray
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Rami Madanat
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA.,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA.,Department of Orthopaedics and Traumatology, Helsinki University Hospital, Helsinki, Finland
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA.,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA.,Department of Orthopaedic Surgery, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
11
|
Beauchamp JE, Vendittoli PA, Barry J, Pelet S, Belzile EL. Catastrophic failure of femoral stem modular junction when combined with metal-on-metal bearing in comparison to ceramic-on-ceramic: A retrospective cohort study. Orthop Traumatol Surg Res 2021; 107:102749. [PMID: 33316446 DOI: 10.1016/j.otsr.2020.102749] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 08/06/2020] [Accepted: 08/17/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND Metal ion release from total hip arthroplasty's (THA) metal-on-metal (MoM) bearing surfaces or head-neck modular junction (trunnionosis) has been identified as a major cause of adverse reaction to metal debris (ARMD). No study has compared the effects of these bearing couples when combined with modular neck femoral stems (MNFS) (i.e. did a modular CoCr have a higher effect than large MoM bearings on whole blood ion concentrations and ARMD). Therefore we did a retrospective comparative analysis of prospectively collected data aiming to: (1) assess the difference in metal ion release between a group of MoM and CoC bearings implanted with a non-cemented MNFS; (2) compare the ARMD and the related revision rates between the two bearing types; (3) compare the patients' HOOS and Harris Hip scores. HYPOTHESIS Metal ion levels and complications rate will be higher in MoM group. METHODS Thirty hips received the same short MNFS with modular CoCr. Seventeen had CoC bearing (16=36mm) and 13 large diameter head (LDH) MoM bearing (mean=50mm, 44-54mm) Both groups had whole blood Cobalt (Co) and Chromium (Cr) concentrations measurements at last follow up or before revision surgery (if any) and were compared to 41 control individuals without implants. ARMD, revision rates and other complications were censed. Functional outcome differences between operative groups were assessed with HOOS and Harris Hip scores. RESULTS Mean whole blood Co and Cr were 1.9μg/L (0.1-10.6 min-max) and 1.2μg/L (0.2-4.6 min-max) in the CoC group and 12.7μg/L (2.5-40.7 min-max) and 8.2μg/L (2.8-40.6 min-max) for MoM group. Controls presented whole blood Co and Cr levels of 0.2μg/L (0.04-0.2 min-max) and 0.6μg/L (0.1-0.7 min-max) respectively. CoC had significantly higher whole blood metal ion concentrations than controls, while MoM had significantly higher concentrations than both (p<0.001). MoM had a 9/13 (69%) revision rate due to ARMD (with stem-neck junction corrosion and wear were present in all cases) while the CoC had none. Functional scores at last follow up did not statistically differ between groups (Harris: CoC=94.1±8.4 vs MoM 91.8±14.8 (p=0.22) and CoC HOOS 90.2±10.7 vs 75.6±21.7 (p=0.08)). CONCLUSION In our study, MNFS with CoCr modular neck released metal ion systemically, as shown in CoC THAs, but when combined with MoM LDH bearings, that elevation was significantly higher. In MNFS MoM, these high metal ion levels translated into a dramatic ARMD related revision rate where stem-neck junction corrosion and wear were present in all cases. More research is required to understand the effects of MoM bearing on neck-stem junctions, and its mechanisms of corrosion. LEVEL OF EVIDENCE III; retrospective comparative study.
Collapse
Affiliation(s)
- Jean-Etienne Beauchamp
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada.
| | - Pascal-André Vendittoli
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Janie Barry
- Department of Surgery, Montreal University, CIUSSS-de-L'Est-de-L'Ile-de-Montréal, Hôpital Maisonneuve-Rosemont (H1T 2M4), 5415 Boulevard L'Assomption, Montreal, QC, Canada
| | - Stéphane Pelet
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| | - Etienne L Belzile
- Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Université Laval (G1V 0A6), Quebec, QC, Canada; Division of Orthopaedic Surgery, CHU de Québec-Université Laval (G1J 1Z4), 1401, 18e rue, Quebec, QC, Canada
| |
Collapse
|
12
|
Martin JR, Odum SM, Springer BD, Griffin WL. Initial metal ion levels predict risk of elevation in metal on metal total hip arthroplasty. Hip Int 2020; 30:592-597. [PMID: 31288570 DOI: 10.1177/1120700019861544] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Screening protocols for asymptomatic patients with metal on metal (MoM) total hip arthroplasty (THA) are evolving. Most surgeons began screening patients around 2010 by obtaining cobalt (Co) and chromium (Cr) metal ion levels. There is currently no data available to guide repeat screening in this familiar clinical scenario. Therefore, the following study evaluated how metal ion levels change after an initial metal ion level in patients with MoM THAs. MATERIALS AND METHODS 171 consecutive patients (265 hips) underwent primary MoM THA. All patients had at least one Co and Cr ion level draw. 84 patients (136 hips) had 2 ion level draws. Ion levels were divided into elevated levels (⩾4.5 ppb) and normal levels (<4.5 ppb). The probability of an ion level returning elevated after an initial normal level was identified. Additionally, a threshold value was determined that reliably identified every patient that did not subsequently rise above 4.5 ppb. RESULTS 12 metal ion levels were ⩾4.5 ppb on the first lab draw. On the second draw, all 12 remained ⩾4.5 ppb. Of the 121 hips with initial metal ion levels <4.5 ppb, 5 metal ion levels became ⩾4.5 ppb. Utilising an initial screening cutoff of 3.0 ppb, no patient was identified with a second lab value ⩾4.5 ppb. DISCUSSION Initial metal ion levels reliably predicted those that would remain elevated or remain normal with a subsequent metal ion level. An initial metal ion level above 3.0 ppb may represent a cutoff at which further workup is necessary.
Collapse
Affiliation(s)
| | - Susan M Odum
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | | | | |
Collapse
|
13
|
Pietiläinen S, Mäntymäki H, Vahlberg T, Reito A, Eskelinen A, Lankinen P, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with bilateral large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2020; 91:378-382. [PMID: 32285731 PMCID: PMC8023891 DOI: 10.1080/17453674.2020.1751940] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Whole-blood (WB) chromium (Cr) and cobalt (Co) measurements are vital in the follow-up of metal-on-metal total hip replacement (MoM THR) patients. We examined whether there is a substantial change in repeated WB, Co, and Cr levels in patients with bilateral ReCap-M2A-Magnum THR. We also specified the number of patients exceeding the safe upper limit (SUL) of WB Co and Cr in the repeated measurement.Patients and methods - We identified 141 patients with bilateral ReCap-M2A-Magnum THR operated in our institution. 61 patients had repeated WB metal ion measurements with bilateral MoM implants still in situ in the second measurement. The mean time elapsing from the first measurement (initial measurement) to the second (control measurement) was 1.9 years (SD = 0.6, range 0.2-3.5). We used earlier established SUL levels for bilateral implants by Van Der Straeten et al. (2013).Results - The median (range) Co and Cr values decreased in the repeated measurement from 2.7 (0.6-25) to 2.1 (0.5-21) and 2.6 (0.8-14) to 2.1 (0.5-18) respectively. In 13% of the patients Co levels exceeded the SUL in the initial measurement and the proportion remained constant, at 13%, in the repeated measurement. In 5% of the patients, Cr levels were above SUL in the initial measurement and an equal 5% in the control measurement.Interpretation - Repeated WB metal ion levels did not increase in patients with bilateral ReCap-M2A-Magnum THR with a mean 1.9-year measurement interval. Long-term development of WB metal ion levels is still unclear in these patients.
Collapse
Affiliation(s)
- Sakari Pietiläinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Heikki Mäntymäki
- Department of Orthopaedics, Tampere University Hospital and University of Turku
| | | | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku
| |
Collapse
|
14
|
Sherafati M, Bauer TW, Potter HG, Koff MF, Koch KM. Multivariate use of MRI biomarkers to classify histologically confirmed necrosis in symptomatic total hip arthroplasty. J Orthop Res 2020; 38:1506-1514. [PMID: 32162716 PMCID: PMC8100875 DOI: 10.1002/jor.24654] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 02/24/2020] [Accepted: 02/29/2020] [Indexed: 02/04/2023]
Abstract
The failure of total hip arthroplasty (THA) is commonly associated with the necrosis of the periprosthetic tissue. To date, there is no established method to noninvasively quantify the progression of such necrosis. Magnetic resonance imaging (MRI) of soft tissues near implants has undergone a recent renaissance due to the development of multispectral metal-artifact reduction techniques. Advanced analysis of multispectral MRI has been shown capable of detecting small magnetism effects of metallic debris in periprosthetic tissue. The purpose of this study is to demonstrate the diagnostic utility of these MRI-based tissue-magnetism signatures. Together with morphological MRI metrics, such as synovial volume and thickness, these measurements are utilized as biomarkers to noninvasively detect soft-tissue necrosis in symptomatic THA patients ( N = 78 ). All subjects underwent an advanced MRI scan before revision surgery and tissue biopsies utilized for necrosis grading. Statistical analyses demonstrated a weak, but significant positive correlation (P = .04) between MRI magnetism signatures and necrosis scores, while indicating no meaningful association between the latter and serum cobalt and chromium ion levels. Receiver-operating characteristic (ROC) analyses were then performed based on uni- and multivariate logistic regression models utilizing the measured MRI biomarkers as predictors of severe necrosis. The area under the curve of the ROC plots for MRI biomarkers as combined predictors were found to be 0.70 and 0.84 for cross-validation and precision-recall tests, respectively.
Collapse
Affiliation(s)
| | - Thomas W. Bauer
- Department of Pathology and Laboratory Medicine, Hospital for Special Surgery, New York, NY
| | - Hollis G. Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY
| | - Matthew F. Koff
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY
| | - Kevin M. Koch
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI
| |
Collapse
|
15
|
Matharu GS, Berryman F, Dunlop DJ, Judge A, Murray DW, Pandit HG. Has the threshold for revision surgery for adverse reactions to metal debris changed in metal-on-metal hip arthroplasty patients? A cohort study of 239 patients using an adapted risk-stratification algorithm. Acta Orthop 2019; 90:530-536. [PMID: 31496340 PMCID: PMC6844394 DOI: 10.1080/17453674.2019.1659661] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - A risk-stratification algorithm for metal-on-metal hip arthroplasty (MoMHA) patients was devised by US experts to help clinicians make management decisions. However, the proposed algorithm did not cover all potential patient or surgical abnormalities. Therefore we adapted the US risk-stratification algorithm in MoMHA patients revised for adverse reactions to metal debris (ARMD) to determine the variability in the revision threshold, and also whether high-risk patients had inferior outcomes following revision.Patients and methods - We analysed 239 MoMHA revisions for ARMD between 2001 and 2016 from 2 centres with pre-revision blood metal ions and imaging. Patients were stratified (low risk, moderate risk, high risk) using pre-revision factors (implant, radiographic, blood metal ions, cross-sectional imaging) by adapting a published algorithm. The risk categories for each factor were assessed against revision year, revision centre, and post-revision outcomes (re-revision surgery, and any poor outcome).Results - Compared with hips revised before 2012, hips revised from 2012 onwards included more high-risk implants (44% vs. 17% pre-2012), high-risk radiographic features (85% vs. 69% pre-2012), and low-risk metal ions (41% vs. 19% pre-2012). 1 centre more frequently revised patients with high-risk implants (48% vs. 14%) and low-risk blood metal ions (45% vs. 15%) compared with the other. All these comparisons were statistically significant (p < 0.05). With the limited sample size available, implant, radiographic, blood metal ion, and cross-sectional imaging risk groups did not statistically significantly affect the rates of re-revision surgery or frequency of poor outcomes post-revision.Interpretation - When applying the adapted risk-stratification algorithm the threshold for ARMD revision changed over time, presumably due to increasing evidence, patient surveillance, and investigation since 2012. Lower blood metal ion thresholds were used from 2012 for ARMD revisions; however, there was evidence that centres attached different importance to metal ions when managing patients. High-risk patients did not have inferior outcomes following ARMD revision.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford;; ,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol;; ,The Royal Orthopaedic Hospital, Birmingham;; ,Correspondence:
| | | | | | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford;; ,Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol;;
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford;;
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford;; ,Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital and University of Leeds, Leeds, UK
| |
Collapse
|
16
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
17
|
Matharu GS, Berryman F, Dunlop DJ, Revell MP, Judge A, Murray DW, Pandit HG. No Threshold Exists for Recommending Revision Surgery in Metal-on-Metal Hip Arthroplasty Patients With Adverse Reactions to Metal Debris: A Retrospective Cohort Study of 346 Revisions. J Arthroplasty 2019; 34:1483-1491. [PMID: 30992241 PMCID: PMC6590389 DOI: 10.1016/j.arth.2019.03.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 02/28/2019] [Accepted: 03/06/2019] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Surgeons currently have difficulty when managing metal-on-metal hip arthroplasty (MoMHA) patients with adverse reactions to metal debris (ARMD). This stems from a lack of evidence, which is emphasized by the variability in the recommendations proposed by different worldwide regulatory authorities for considering MoMHA revision surgery. We investigated predictors of poor outcomes following MoMHA revision surgery performed for ARMD to help inform the revision threshold and type of reconstruction. METHODS We retrospectively studied 346 MoMHA revisions for ARMD performed at 2 European centers. Preoperative (metal ions/imaging) and intraoperative (findings, components removed/implanted) factors were used to predict poor outcomes. Poor outcomes were postoperative complications (including re-revision), 90-day mortality, and poor Oxford Hip Score. RESULTS Poor outcomes occurred in 38.5%. Shorter time (under 4 years) to revision surgery was the only preoperative predictor of poor outcomes (odds ratio [OR] = 2.12, confidence interval [CI] = 1.00-4.46). Prerevision metal ions and imaging did not influence outcomes. Single-component revisions (vs all-component revisions) increased the risk of poor outcomes (OR = 2.99, CI = 1.50-5.97). Intraoperative modifiable factors reducing the risk of poor outcomes included the posterior approach (OR = 0.22, CI = 0.10-0.49), revision head sizes ≥36 mm (vs <36 mm: OR = 0.37, CI = 0.18-0.77), ceramic-on-polyethylene revision bearings (OR vs ceramic-on-ceramic = 0.30, CI = 0.14-0.66), and metal-on-polyethylene revision bearings (OR vs ceramic-on-ceramic = 0.37, CI = 0.17-0.83). CONCLUSION No threshold exists for recommending revision in MoMHA patients with ARMD. However postrevision outcomes were surgeon modifiable. Optimal outcomes may be achieved if surgeons use the posterior approach, revise all MoMHA components, and use ≥36 mm ceramic-on-polyethylene or metal-on-polyethylene articulations.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom; Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, United Kingdom; Research Department, The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Fiona Berryman
- Research Department, The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - David J Dunlop
- Research Department, The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Matthew P Revell
- Research Department, The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom; Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, United Kingdom
| | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom; Leeds Institute of Rheumatic and Musculoskeletal Medicine, Chapel Allerton Hospital, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
18
|
Mäntymäki H, Lankinen P, Vahlberg T, Reito A, Eskelinen A, Mäkelä K. Repeated cobalt and chromium ion measurements in patients with large-diameter head metal-on-metal ReCap-M2A-Magnum total hip replacement. Acta Orthop 2019; 90:243-248. [PMID: 30945585 PMCID: PMC6534222 DOI: 10.1080/17453674.2019.1595469] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Whole blood (WB) cobalt (Co) and chromium (Cr) ion levels have a major role in the follow-up of metal-on-metal total hip replacement (MoM THR). We investigated, first, if there was a change in WB Co or Cr levels over repeated measurements in patients with ReCap-M2A-Magnum THR, and, second, determined how many patients had WB Co or Cr levels that exceeded the safe upper limits (SUL) in the repeated whole blood metal ion assessment. Patients and methods - A Recap-M2A-Magnum THR was used in 1,329 operations (1,188 patients) at our institution between 2005 and 2012. We identified all patients (n = 319) with unilateral ReCap-M2A-Magnum implants who had undergone at least 2 repeated metal ion measurements with the first blood sample taken mean 5.5 years (1.8-9.3) after surgery and the second taken mean 2 years (0.5-3) after the first. Results - The median WB Co and Cr ion levels decreased in repeated measurements from 1.40 (0.40-63) ppb to 1.10 (0.20-68) ppb and from 1.60 (0.60-13.0) ppb to 1.10 (0.30-19.0) ppb, respectively. 7% of the Co ion values exceeded SUL at the initial measurement, and 7% at the control measurement. The proportion of Cr ion values exceeding the safe upper limit (SUL) decreased during the measurement interval from 5% to 4%. Interpretation - Repeated metal ion measurements in unilateral ReCap-M2A-Magnum patients in a mean 2-year time interval did not show any increase. Long-term ion levels are, however, not yet known.
Collapse
Affiliation(s)
- Heikki Mäntymäki
- Department of Orthopaedics, Tampere University Hospital and University of Turku;; ,Correspondence:
| | - Petteri Lankinen
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;;
| | | | - Aleksi Reito
- Coxa Hospital for Joint Replacement and University of Tampere, Finland
| | - Antti Eskelinen
- Coxa Hospital for Joint Replacement and University of Tampere, Finland
| | - Keijo Mäkelä
- Department of Orthopaedics and Traumatology, Turku University Hospital and University of Turku;;
| |
Collapse
|
19
|
Juneau D, Grammatopoulos G, Alzahrani A, Thornhill R, Inacio JR, Dick A, Vogel KI, Dobransky J, Beaulé PE, Dwivedi G. Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? Bone Joint J 2019; 101-B:540-546. [DOI: 10.1302/0301-620x.101b5.bjj-2018-1478.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Aims Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. Patients and Methods In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. Results None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2 vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2 vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. Conclusion Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540–546.
Collapse
Affiliation(s)
- D. Juneau
- Department of Radiology and Nuclear Medicine, Centre Hospitalier de l’Université de Montréal (CHUM), Montréal, Canada
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - G. Grammatopoulos
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - A. Alzahrani
- King Saud bin Abdulaziz University for Health Sciences, King Faisal Cardiac Center, Jeddah, Saudi Arabia
| | - R. Thornhill
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - J. R. Inacio
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - A. Dick
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - K. I. Vogel
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - J. Dobransky
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - P. E. Beaulé
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
- University of Ottawa, Ottawa, Canada
| | - G. Dwivedi
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
- Consultant in Cardiology and Professor of Cardiology, The University of Western Australia, Harry Perkins Institute of Medical Research and Fiona Stanley Hospital, Perth, Australia
| |
Collapse
|
20
|
What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study. Clin Orthop Relat Res 2019; 477:353-360. [PMID: 30794223 PMCID: PMC6370095 DOI: 10.1097/corr.0000000000000393] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Adverse local tissue reaction (ALTR) is not only a prominent cause of metal-on-metal (MoM) implant revision, but may also compromise the result of revision surgery. Patients treated with MoM arthroplasty and subsequently revised as a result of ALTR have been shown to experience worse patient-reported outcomes, inferior survivorship, and more complications when compared with patients receiving MoM implants who were revised for reasons other than ALTR. There is conflicting evidence as to whether the presence of symptoms is associated with ALTR in patients with MoM implants. Blood metal ions are associated with ALTR, but a consensus on appropriate thresholds associated with ALTR risk is lacking. QUESTIONS/PURPOSES (1) Was the presence of symptoms as measured by patient-reported outcome measures associated with ALTR presence and severity as noted on metal artifact reduction sequence (MARS)-MRI in patients treated with one design of MoM THA or hip resurfacing arthroplasty (HRA)? (2) Could reliable thresholds for blood metal ion levels be determined that were associated with ALTR presence on MARS-MRI? METHODS This retrospective study presents a secondary analysis of data drawn from a prospective, international, multicenter study of the recalled Articular Surface Replacement (ASR) hip system. This larger study aims to identify risk factors for revision and provide followup guidelines for the many unrevised ASR patients. A total of 1721 patients were enrolled from 16 centers in six countries after the device was recalled and are followed annually for 5 years. In the present analysis, data from the enrollment visit (mean time from index surgery, 7.5 years; SD 3.5 years) were considered. Only patients from two centers conducting MARS-MRI on all patients regardless of clinical presentation as a standard of care were included to avoid selection bias. A total of 327 unilateral patients fulfilled our inclusion criteria (90% of those eligible). The level of symptoms was systematically determined using the Harris hip score and a visual analog scale for pain, and whole blood metal ion levels were collected from all patients. MARS-MRIs were analyzed by a single reader for ALTR presence (Anderson classification), diameter, and synovial thickness. A validation series of 35 MARS-MRIs indicated excellent intrareader reproducibility of the evaluations (intraclass correlation = 0.82) and substantial agreement (κ coefficient = 0.64) was achieved between the MARS-MRI reader and a musculoskeletal radiologist with > 10 years of experience with MARS-MRI. Binary logistic regression was used to determine variables independently associated with ALTR. Receiver operator characteristic curves were used to determine sensitive and specific cut points for cobalt and chromium. RESULTS After controlling for confounding variables, presence of symptoms was determined to be a risk factor for ALTR (odds ratio, 2.9; p = 0.007) in patients treated with ASR MoM THA. Moreover, among patients undergoing ASR MoM THA with ALTR, synovial thickness correlated with symptomaticity (p = 0.030). For patients undergoing ASR MoM HRA, we found no association between symptoms and ALTR prevalence or severity. A cobalt cutoff of 3.2 parts per billion (ppb) was associated with increased risk of ALTR (p < 0.001; sensitivity, 68%; specificity, 71%) in ASR MoM THA. In patients with ASR MoM HRA, a cobalt threshold of 2.9 ppb was indicative of ALTR (p < 0.001; sensitivity, 79%; specificity, 69%). CONCLUSIONS The risk factors identified in the current study may be used to stratify patients receiving MoM implants in terms of ALTR risk. We found that symptoms are associated with an increased likelihood of ALTR presence in ASR MoM THA and that cobalt ion level is associated with ALTR in ASR MoM THA as well as ASR MoM HRA. Importantly, MoM HRA followup protocols that exempt asymptomatic patients from annual followup are not justified because asymptomatic patients are no less likely to have ALTR than symptomatic patients. Blood metal ion levels may reliably be used to screen patients undergoing MoM HRA. For patients undergoing MoM THA, a combination of symptom state and blood metal ion levels may be used to determine ALTR risk. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
|
21
|
Tashjian RZ, Chalmers PN. Future Frontiers in Shoulder Arthroplasty and the Management of Shoulder Osteoarthritis. Clin Sports Med 2018; 37:609-630. [DOI: 10.1016/j.csm.2018.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
22
|
Hunt LP, Blom AW, Matharu GS, Porter ML, Whitehouse MR. The risk of developing cancer following metal-on-metal hip replacement compared with non metal-on-metal hip bearings: Findings from a prospective national registry "The National Joint Registry of England, Wales, Northern Ireland and the Isle of Man". PLoS One 2018; 13:e0204356. [PMID: 30235326 PMCID: PMC6147563 DOI: 10.1371/journal.pone.0204356] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Accepted: 09/06/2018] [Indexed: 12/13/2022] Open
Abstract
Background and purpose Over 1 million metal-on-metal hip replacements were implanted. Even well-functioning implants produce wear debris that can cause tissue damage, disseminate and cause DNA damage. We aimed to establish if there was an association between metal-on-metal hip replacement and the risk of subsequently developing cancer compared with alternative hip replacements. Methods We performed a population based prospective longitudinal cohort study using data from the National Joint Registry linked to Hospital Episode Statistics (n = 403,881 patients). We examined the incidence of a new diagnosis of cancer in patients who received a metal-on-metal bearing in comparison with those who received a non metal-on-metal bearing. Kaplan-Meier estimates of time to first cancer diagnosis were used with Cox proportional hazards regression models to assess the effect on the time to cancer diagnosis for all cancer types, haematological, malignant melanoma, urinary tract cancers or prostate cancer in men. Results The maximum follow up available was 11.8 years with 25% of patients followed up for more than 6.8 years (mean follow up 4.6 years; median 4.3; IQR 2.1–6.8; range 0.01–11.8). Analyses by gender that adjusted for age at primary and presence or absence of linked Welsh (PEDW) records showed no increase in the risk of developing cancer according to the bearing surface implanted for all cancers, haematological cancers, malignant melanoma, urinary tract cancers or prostate cancer in men. For patients receiving a second hip replacement, there was also no difference. Conclusion We have demonstrated that there is currently no evidence of an increase in the risk of cancer following primary hip replacement according to the type of bearing material used. Although the risk of revision in metal-on-metal bearing hip replacements is higher, it is reassuring that the risk of a new diagnosis of cancer is not currently increased. Despite the long term follow up available in this study, the latency period for some cancers is very long and therefore continued monitoring is required to ensure no new patterns emerge that may indicate need for universal screening.
Collapse
Affiliation(s)
- Linda P. Hunt
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Ashley W. Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
| | - Gulraj S. Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
| | - Martyn L. Porter
- Centre for Hip Surgery, Wrightington Hospital, Wrightington, Lancashire, United Kingdom
- * E-mail: (MRW); (MLP)
| | - Michael R. Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol & Southmead Hospital, Bristol, United Kingdom
- National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, United Kingdom
- * E-mail: (MRW); (MLP)
| |
Collapse
|
23
|
Matharu GS, Judge A, Eskelinen A, Murray DW, Pandit HG. What is appropriate surveillance for metal-on-metal hip arthroplasty patients? Acta Orthop 2018; 89:29-39. [PMID: 29105547 PMCID: PMC5810829 DOI: 10.1080/17453674.2017.1398011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory authorities recommending regular surveillance, even for asymptomatic individuals. However, these recommendations are not evidence-based and are very costly. The rapidly evolving evidence base requires an update regarding the investigation and management of MoMHA patients. This article is the first of 2 (the second article in this series will consider the threshold for performing revision, and the outcomes following ARMD revision surgery: Matharu et al., Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update. Acta Orthop 2018; in press), and considers the various investigative modalities used during surveillance, with specific focus on blood metal ion sampling and cross-sectional imaging. No single investigation can universally be used during MoMHA patient surveillance. Recent studies have now provided important information on interpreting blood metal ions (effective in identifying patients at low risk of problems), clarifying the roles of cross-sectional imaging (reserve combined ultrasound and MARS-MRI for complex cases), and providing parameters to safely exclude many asymptomatic patients from regular surveillance. This information will be useful when designing future surveillance protocols for MoMHA patients.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK;,Correspondence:
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | | | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| |
Collapse
|
24
|
Kiran M, Armstrong C, Shivarathre D, Peter VK. Blood Metal Ion Levels Have Limited Utility in the Surveillance of Asymptomatic Large-Head Metal-on-Metal Total Hip Arthroplasties. J Arthroplasty 2017; 32:3685-3688. [PMID: 28781016 DOI: 10.1016/j.arth.2017.07.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 06/26/2017] [Accepted: 07/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Blood cobalt (Co) and chromium (Cr) ion levels have been used as surveillance tools for adverse reaction to metal debris (ARMD) in metal-on-metal (MoM) articulations with varying thresholds in different countries. The aim of our study is to present the serial 12-year blood Co and Cr levels in a cohort of MoM total hip arthroplasties (THAs) with femoral head size ≥36 mm and analyze their utility in asymptomatic patients at current thresholds. METHODS A total of 256 patients with unilateral MoM THA with femoral head size ≥36 mm were included in this study with data collected prospectively. The implants used were Birmingham hip resurfacing cup-Freeman stem (BHR-F) or an Articular Surface Resurfacing cup-Corail/S-ROM stem. Annual follow-up with blood Co and Cr measurements was done as per Medicines and Healthcare Products Regulatory Agency (MHRA) of the United Kingdom guidelines. Receiver operating characteristic curve was plotted based on the sensitivity and specificity of blood metal ion values to detect ARMD. The metal ion levels in asymptomatic patients were analyzed separately. RESULTS Receiver operating characteristic curves showed poor discriminatory ability for both Co and Cr values in predicting ARMD at 7 μg/L. The sensitivity of Co and Cr was 82.1% and 53.5%, respectively, and their positive predictive values were 43.8% and 67.6%, respectively. After 7 years, there was no significant change in Co values, and there was a decline in Cr value after 9 years in asymptomatic patients. CONCLUSION To the best of our knowledge, this is the first study to describe the behavior of serial blood metal ion levels in asymptomatic large-diameter MoM THA. We suggest that annual blood Co and Cr have limited discriminant capacity in diagnosing the occurrence of metallosis and their measurement beyond 7 years is of limited utility in asymptomatic patients.
Collapse
Affiliation(s)
- Manish Kiran
- Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen Hospital, Liverpool, United Kingdom
| | - Catherine Armstrong
- Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen Hospital, Liverpool, United Kingdom
| | - Deepak Shivarathre
- Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen Hospital, Liverpool, United Kingdom
| | - Viju K Peter
- Department of Trauma and Orthopaedics, Royal Liverpool and Broadgreen Hospital, Liverpool, United Kingdom
| |
Collapse
|
25
|
Matharu GS, Berryman F, Judge A, Reito A, McConnell J, Lainiala O, Young S, Eskelinen A, Pandit HG, Murray DW. Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants. J Bone Joint Surg Am 2017; 99:1532-1539. [PMID: 28926382 PMCID: PMC5805279 DOI: 10.2106/jbjs.16.01568] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The authors of recent studies have reported newly devised implant-specific blood metal ion thresholds to predict adverse reactions to metal debris (ARMD) in patients who have undergone unilateral or bilateral metal-on-metal (MoM) hip arthroplasty. These thresholds were most effective for identifying patients at low risk of ARMD. We investigated whether these newly devised blood metal ion thresholds could effectively identify patients at risk of ARMD after MoM hip arthroplasty in an external cohort of patients. METHODS We performed a validation study involving 803 MoM hip arthroplasties (323 unilateral Birmingham Hip Resurfacing [BHR], 93 bilateral BHR, and 294 unilateral Corail-Pinnacle implants) performed in 710 patients at 3 European centers. All patients underwent whole-blood metal ion sampling, and were divided into 2 groups: those with ARMD (leading to revision or identified on imaging; n = 75) and those without ARMD (n = 635). Previously devised implant-specific blood metal ion thresholds (2.15 μg/L of cobalt for unilateral BHR; 5.5 μg/L for the maximum of either cobalt or chromium for bilateral BHR; and 3.57 μg/L of cobalt for unilateral Corail-Pinnacle implants) were applied to the validation cohort, and receiver operating characteristic curve analysis was used to establish the discriminatory characteristics of each threshold. RESULTS The area under the curve, sensitivity, specificity, and positive and negative predictive values for the ability of each implant-specific threshold to distinguish between patients with and without ARMD were, respectively, 89.4% (95% confidence interval [CI] = 82.8% to 96.0%), 78.9%, 86.7%, 44.1%, and 96.9% for unilateral BHR; 89.2% (CI = 81.3% to 97.1%), 70.6%, 86.8%, 54.5%, and 93.0% for bilateral BHR; and 76.9% (CI = 63.9% to 90.0%), 65.0%, 85.4%, 24.5%, and 97.1% for unilateral Corail-Pinnacle implants. Using the implant-specific thresholds, we missed 20 patients with ARMD (2.8% of the patients in this series). We missed more patients with ARMD when we used the fixed thresholds proposed by regulatory authorities: 35 (4.9%) when we used the U.K. threshold of 7 μg/L for both cobalt and chromium (p = 0.0003), 21 (3.0%) when we used the U.S. threshold of 3 μg/L for both cobalt and chromium (p = 1.0), and 46 (6.5%) when we used the U.S. threshold of 10 μg/L for both cobalt and chromium (p < 0.0001). CONCLUSIONS This external multicenter validation study confirmed that patients with blood metal ion levels below new implant-specific thresholds have a low risk of ARMD after MoM hip arthroplasty. Using these implant-specific thresholds, we missed fewer patients with ARMD compared with when the thresholds currently proposed by regulatory authorities were used. We therefore recommend using implant-specific blood metal ion thresholds when managing patients who have undergone MoM hip arthroplasty. LEVEL OF EVIDENCE Diagnostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Gulraj S. Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Fiona Berryman
- The Royal Orthopaedic Hospital, Birmingham, United Kingdom
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- MRC Lifecourse Epidemiology Unit, Southampton General Hospital, University of Southampton, Southampton, United Kingdom
| | - Aleksi Reito
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | - Olli Lainiala
- Coxa Hospital for Joint Replacement, Tampere, Finland
| | | | | | - Hemant G. Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), Chapel Allerton Hospital, Leeds, United Kingdom
| | - David W. Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Nuffield Orthopaedic Centre, Oxford, United Kingdom
| |
Collapse
|
26
|
Fillingham YA, Della Valle CJ, Bohl DD, Kelly MP, Hall DJ, Pourzal R, Jacobs JJ. Serum Metal Levels for Diagnosis of Adverse Local Tissue Reactions Secondary to Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty 2017; 32:S272-S277. [PMID: 28511949 DOI: 10.1016/j.arth.2017.04.016] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 03/28/2017] [Accepted: 04/10/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Recently, corrosion at the head-neck junction in metal-on-polyethylene bearing surface total hip arthroplasty (THA) has been recognized as a cause of adverse local tissue reactions (ALTRs). Serum metal levels have been advocated as a tool for the diagnosis of ALTR; however, no prior studies have specifically examined their utility. The purpose of this study was to determine the optimal cutoff values for serum cobalt and chromium levels in diagnosing ALTR after metal-on-polyethylene bearing surface THA. METHODS We reviewed 447 consecutive patients with serum metal levels tested at our institution and identified 64 patients with a metal-on-polyethylene bearing who had axial imaging or underwent reoperation to confirm the presence or absence of ALTR. Receiver-operating characteristic curves were produced to identify cutoff thresholds to optimize sensitivity, and diagnostic test performance was characterized. RESULTS Forty-four of the 64 patients (69%) were positive for an ALTR. The best test for the diagnosis of ALTR was the serum cobalt level (area under the curve [AUC] = 99%). A threshold cutoff of ≥1.0 ng/mL had a sensitivity of 100%, specificity of 90%, positive predictive value (PPV) of 96%, and negative predictive value (NPV) of 100%. Serum chromium levels were also diagnostic (AUC = 87%). A threshold cutoff of ≥0.15 ng/mL had a sensitivity of 100%, specificity of 50%, PPV of 81%, and NPV of 100%. Finally, serum cobalt-to-chromium ratio was also helpful for diagnosis (AUC = 90%). A threshold cutoff value of 1.4 for the cobalt-to-chromium ratio offered a sensitivity of 93%, specificity of 70%, PPV of 87%, and NPV of 82%. CONCLUSION Measurement of serum cobalt level with a threshold value of 1.0 ng/mL in our experience is the best test for identifying the presence of ALTR in patients with a metal-on-polyethylene THA. Measurement of chromium level and the ratio of cobalt-to-chromium levels are also of value.
Collapse
Affiliation(s)
- Yale A Fillingham
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Craig J Della Valle
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Daniel D Bohl
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Mick P Kelly
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Deborah J Hall
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Robin Pourzal
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Joshua J Jacobs
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| |
Collapse
|
27
|
Carlson BC, Bryan AJ, Carrillo-Villamizar NT, Sierra RJ. The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2017; 32:S214-S219. [PMID: 28320566 DOI: 10.1016/j.arth.2017.02.031] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/03/2017] [Accepted: 02/11/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There is a paucity of data examining metal ion levels over time. METHODS We retrospectively reviewed 59 patients (69 hips) with an articular surface replacement total hip arthroplasty. We reviewed prerevision cobalt and chromium concentrations over time. RESULTS Seventy-one percent of patients who were revised and had multiple ion measurements (12/17) demonstrated increasing cobalt ion levels or elevated ion levels over time. There was a trend toward an elevated risk of revision for increasing cobalt and chromium levels starting at 12 and 4 ppb, respectively; this was significant for chromium levels above 7 ppb (hazard ratio 22.35, P = .001). Similarly, there was a trend toward an elevated risk of pseudotumor formation for increasing cobalt and chromium levels starting at 5 and 2.5 ppb, respectively; this was significant for cobalt levels above 7 ppb (hazard ratio 6.88, P = .027). CONCLUSION In this paper, cobalt and chromium levels levels above 5 and 2.5 ppb started to demonstrate an increased risk of ARMD, and should be considered as a lower cutoff for discussion with patients about the potential for future revision.
Collapse
Affiliation(s)
- Bayard C Carlson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Andrew J Bryan
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
28
|
Cobalt Cardiomyopathy Secondary to Hip Arthroplasty: An Increasingly Prevalent Problem. Case Rep Cardiol 2017; 2017:5434571. [PMID: 28845313 PMCID: PMC5563425 DOI: 10.1155/2017/5434571] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Accepted: 01/26/2017] [Indexed: 11/17/2022] Open
Abstract
A forty-year-old man experienced worsening heart failure four years following bilateral complicated total hip replacement. His condition was extensively worked up but no underlying pathology was immediately evident. Given the cobalt-chromium alloy component present in the hip arthroplasties, the raised cobalt blood levels, and a fitting clinical picture coupled with radiological findings, the patient underwent right hip revision. Evidence of biotribocorrosion was present on direct visualisation intraoperatively. The patient subsequently experienced symptomatic improvement (NYHA class III to class I) and echocardiography showed recovery of ejection fraction. Cobalt exists as a bivalent and trivalent molecule in circulation and produces a cytotoxicity profile similar to nanoparticles, causing neurological, thyroid, and cardiological pathology. Blood levels are not entirely useful as there is no identifiable conversion factor for levels in whole blood, serum, and erythrocytes which seem to act independently of each other. Interestingly cobalt cardiomyopathy is frequently compounded by other possible causes of cardiomyopathy such as alcohol and a link has been postulated. Definitive treatment is revision of the arthroplasty as other treatments are unproven.
Collapse
|
29
|
Matharu GS, Nandra RS, Berryman F, Judge A, Pynsent PB, Dunlop DJ. Risk factors for failure of the 36 mm metal-on-metal Pinnacle total hip arthroplasty system: a retrospective single-centre cohort study. Bone Joint J 2017; 99-B:592-600. [PMID: 28455467 PMCID: PMC5413867 DOI: 10.1302/0301-620x.99b5.bjj-2016-1232.r1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 12/30/2016] [Indexed: 12/12/2022]
Abstract
Aims To determine ten-year failure rates following 36 mm metal-on-metal
(MoM) Pinnacle total hip arthroplasty (THA), and identify predictors
of failure. Patients and Methods We retrospectively assessed a single-centre cohort of 569 primary
36 mm MoM Pinnacle THAs (all Corail stems) followed up since 2012
according to Medicines and Healthcare Products Regulation Agency
recommendations. All-cause failure rates (all-cause revision, and
non-revised cross-sectional imaging failures) were calculated, with predictors
for failure identified using multivariable Cox regression. Results Failure occurred in 97 hips (17.0%). The ten-year cumulative
failure rate was 27.1% (95% confidence interval (CI) 21.6 to 33.7).
Primary implantation from 2006 onwards (hazard ratio (HR) 4.30;
95% CI 1.82 to 10.1; p = 0.001) and bilateral MoM hip arthroplasty
(HR 1.59; 95% CI 1.03 to 2.46; p = 0.037) predicted failure. The
effect of implantation year on failure varied over time. From four
years onwards following surgery, hips implanted since 2006 had significantly
higher failure rates (eight years 28.3%; 95% CI 23.1 to 34.5) compared
with hips implanted before 2006 (eight years 6.3%; 95% CI 2.4 to
15.8) (HR 15.2; 95% CI 2.11 to 110.4; p = 0.007). Conclusion We observed that 36 mm MoM Pinnacle THAs have an unacceptably
high ten-year failure rate, especially if implanted from 2006 onwards
or in bilateral MoM hip patients. Our findings regarding implantation
year and failure support recent concerns about the device manufacturing
process. We recommend all patients undergoing implantation since
2006 and those with bilateral MoM hips undergo regular investigation,
regardless of symptoms. Cite this article: Bone Joint J 2017;99-B:592–600.
Collapse
Affiliation(s)
| | - R S Nandra
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - F Berryman
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| | - A Judge
- University of Oxford, Oxford, OX3 7LD, UK
| | - P B Pynsent
- School of Clinical and Experimental Medicine, University of Birmingham, B15 2TT, UK
| | - D J Dunlop
- The Royal Orthopaedic Hospital, Birmingham, B31 2AP, UK
| |
Collapse
|
30
|
McGrory BJ, Payson AM, MacKenzie JA. Elevated Intra-Articular Cobalt and Chromium Levels in Mechanically Assisted Crevice Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty. J Arthroplasty 2017; 32:1654-1658. [PMID: 28041772 DOI: 10.1016/j.arth.2016.11.056] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 11/14/2016] [Accepted: 11/29/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Failed total hip arthroplasty (THA) caused by mechanically assisted crevice corrosion (MACC) has serious consequences such as adverse local tissue reaction (ALTR). Serum cobalt (Co) and chromium (Cr) ion levels have been used to diagnose taper corrosion, but have not been shown to be an accurate measure of the severity of MACC or associated ALTRs. Additionally, elevated serum ions are not specific in patients with multiple artificial joints. METHODS We examined the relationship between serum and intra-articular (IA) Co and Cr levels in a cohort of 20 patients undergoing revision THA, 16 who had symptomatic MACC. IA Co and Cr levels in MACC patients were compared with demographic, pre-operative, and operative findings. RESULTS Serum and IA metal levels were found to be relatively low in THA patients undergoing revision surgery for isolated instability, aseptic loosening, or infection (average serum Co 0.03 ppb [parts per billion], IA Co 1.4 ppb, serum Cr 0.32 ppb, IA Cr 3.3 ppb). In patients with MACC, average IA Co (940 ppb) was significantly higher than serum Co (5.1 ppb) (P = .0003) and IA Cr (491 ppb) was significantly higher than serum Cr (1.3 ppb) (P = .0003). IA Co level was associated with shorter time of hip symptoms to revision surgery (P = .0043). CONCLUSION Serum levels of Co and Cr correlated with joint levels in the entire cohort, but IA levels of MACC patients were 100 times greater than serum levels. IA Co and Cr levels may be useful in confirming MACC in a specific joint and the striking elevation may explain symptoms and ALTR with relatively low serum values.
Collapse
Affiliation(s)
- Brian J McGrory
- Tufts University School of Medicine, Boston, Massachusetts; Maine Joint Replacement Institute, Portland, Maine; Maine Medical Center Division of Joint Replacements, Falmouth, Maine
| | | | | |
Collapse
|
31
|
Matharu GS, Berryman F, Brash L, Pynsent PB, Dunlop DJ, Treacy RBC. Can blood metal ion levels be used to identify patients with bilateral Birmingham Hip Resurfacings who are at risk of adverse reactions to metal debris? Bone Joint J 2017; 98-B:1455-1462. [PMID: 27803220 DOI: 10.1302/0301-620x.98b11.38042] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Accepted: 07/29/2016] [Indexed: 11/05/2022]
Abstract
AIMS We investigated whether blood metal ion levels could effectively identify patients with bilateral Birmingham Hip Resurfacing (BHR) implants who have adverse reactions to metal debris (ARMD). PATIENTS AND METHODS Metal ion levels in whole blood were measured in 185 patients with bilateral BHRs. Patients were divided into those with ARMD who either had undergone a revision for ARMD or had ARMD on imaging (n = 30), and those without ARMD (n = 155). Receiver operating characteristic analysis was used to determine the optimal thresholds of blood metal ion levels for identifying patients with ARMD. RESULTS The maximum level of cobalt or chromium ions in the blood was the parameter which produced the highest area under the curve (91.0%). The optimal threshold for distinguishing between patients with and without ARMD was 5.5 µg/l (83.3% sensitivity, 88.4% specificity, 58.1% positive and 96.5% negative predictive values). Similar results were obtained in a subgroup of 111 patients who all underwent cross-sectional imaging. Between 3.2% and 4.3% of patients with ARMD were missed if United Kingdom (7 µg/l) and United States (10 µg/l) authority thresholds were used respectively, compared with 2.7% if our implant specific threshold was used, though these differences did not reach statistical significance (p ≥ 0.248). CONCLUSION Patients with bilateral BHRs who have blood metal ion levels below our implant specific threshold were at low-risk of having ARMD. Cite this article: Bone Joint J 2016;98-B:1455-62.
Collapse
Affiliation(s)
- G S Matharu
- The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK and Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford OX3 7LD, UK
| | - F Berryman
- The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK
| | - L Brash
- The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK
| | - P B Pynsent
- University of Birmingham, Birmingham B15 2TT, UK
| | - D J Dunlop
- The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK
| | - R B C Treacy
- The Royal Orthopaedic Hospital, Birmingham B31 2AP, UK
| |
Collapse
|
32
|
Abstract
Cobalt can cause a distinctive, rapidly progressive and reversible depression of cardiac systolic function, which is readily distinguished from other causes of cardiomyopathy. Patients present with the subacute onset of severe heart failure, which is accompanied by hypotension and cyanosis, pericardial effusion, low voltage on the electrocardiogram, marked elevation of serum enzymes, and lactic acidosis. They typically have a history of lethargy, anorexia, and weight loss in the months preceding the illness and exhibit other evidence of cobalt’s effects on the body (eg, polycythemia and goiter). The course of cobalt-related cardiomyopathy may be progressive and fatal, but those who survive and cease exposure generally demonstrate complete resolution of symptoms and recovery of cardiac function. Patients presenting with rapid onset of cardiomyopathy, who also exhibit polycythemia, pericardial effusion, or goiter should be evaluated for cobalt exposure. Exposure can be confirmed by the measurement of cobalt in the serum, but serum levels of the ion are not reliably predictive of clinical cardiotoxicity. The clinical emergence of cobalt cardiomyopathy seems to require the coexistence of one or more cofactors, particularly a low-protein diet, thiamine deficiency, alcoholism, and hypothyroidism. As the medicinal use of cobalt has waned and measures to reduce industrial exposure have been implemented, subacute cobalt-related cardiomyopathy had become rare. However, reports describing classical features of the disease have recently surged among patients with a malfunctioning cobalt-alloy hip prosthesis.
Collapse
Affiliation(s)
- Milton Packer
- From the Baylor Heart and Vascular Institute, Baylor University Medical Center, Dallas, TX
| |
Collapse
|