1
|
Ikeda S, Kaku N, Hosoyama T, Tsumura H. Survival rates of different bearing surfaces with the same model of stem in total hip arthroplasty: predictive factors for revision surgery. Arch Orthop Trauma Surg 2022:10.1007/s00402-022-04706-9. [PMID: 36443614 DOI: 10.1007/s00402-022-04706-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 11/21/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Few studies have examined the survival rates of total hip arthroplasty (THA) with the same femoral stem, and the predictive factors leading to the revision of stemmed metal-on-metal (MoM) THA remain unknown. We determined the long-term survival rate of stemmed MoM THA compared with that of metal-on-polyethylene (MoP) bearing THA, the effect of head size and cup placement angle on revision rate, and predictors of revision. MATERIALS AND METHODS A total of 130 hips in 110 patients who underwent primary THA by the same surgeon were included. M2a-RingLoc with a metal-on-polyethylene bearing (group P, 53 hips), M2a-Taper with MoM bearing (group T, 44 hips), and M2a-Magnum with MoM bearing (group M, 33 hips) were used. The mean age at surgery was 63.1 ± 9.5 years, and the mean postoperative follow-up duration was 133.7 ± 39.1 months. Whole blood metal ion concentrations were measured preoperatively and postoperatively, and magnetic resonance imaging was performed to identify aseptic local tissue reactions (ALTRs). Kaplan-Meier survivorship analysis and multiple logistic regression analysis were performed. RESULTS The THA survival rate up to the maximum postoperative follow-up period was 96.2% at 173 months, 46.6% at 179 months, and 47.8% at 145 months in groups P, T, and M, respectively, with revision as the endpoint. The stemmed MoM THA recorded a very low survival rate (p < 0.001). The ALTR rates were 70.5% and 63.6% in groups T and M, respectively. The risk factor for revision was the use of MoM bearing, and there was no difference in the results based on the head size in group M. Cobalt levels continued to increase postoperatively, although they were not accurate predictors of revision. CONCLUSIONS Stemmed MoM THA has a very low survival rate and should be used with caution. It is important to monitor the patient's symptoms and perform appropriate imaging to ensure timely revision.
Collapse
Affiliation(s)
- Shinichi Ikeda
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| | - Nobuhiro Kaku
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan.
| | - Tsuguaki Hosoyama
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| | - Hiroshi Tsumura
- Department of Orthopaedic Surgery, Faculty of Medicine, Oita University, 1-1 Idaigaoka Hasama-Machi, Yufu, Oita, 879-5593, Japan
| |
Collapse
|
2
|
Agarwala S, Vijayvargiya M. Predictive factors affecting long-term survivorship of ASR metal-on-metal total hip arthroplasty. SICOT J 2021; 7:51. [PMID: 34668856 PMCID: PMC8527991 DOI: 10.1051/sicotj/2021040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Accepted: 07/14/2021] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION We present the outcome of 154 ASR (Articular Surface Replacement) hips performed at the P.D Hinduja Hospital and Medical Research Centre in terms of revision rate, metal ion levels, and factors affecting survivorship. Further, determined the importance of serial metal ion estimation over single value with poorly functioning arthroplasties. METHODS A retrospective study of 154 ASR arthroplasties (136 patients) performed from April 2005 till March 2010 was conducted. Ninety-seven patients were available for final analysis. All patients were assessed for symptoms, radiographs, blood metal (chromium and cobalt), metal artefact reduction sequence (MARS), magnetic resonance imaging (MRI), and computerized tomography (CT). RESULTS Female gender, smaller femoral head, patients with a rising level of metal ion levels were more likely to have revision surgery. However, abnormal acetabular inclination/anteversion was not associated with the occurrence of raised metal ion levels, ARMD (adverse reaction to metal debris) or revision surgery. Patients with raised metal ion levels were more likely to have periprosthetic lucency, ARMD, and revision surgery. Median metal levels increased initially for the first three years. Still, patients who required revision surgery continued to have a metal ion rise until the point when revision surgery was performed. In contrast, patients who had a fall in metal ion levels did not require revision. CONCLUSION A single metal ion value is less predictive of failing arthroplasties; instead, a rising trend of metal ion levels can better delineate arthroplasties which will require revision. ASR hips whose blood ion levels fell after an initial rise and showed a declining trend did well.
Collapse
Affiliation(s)
- Sanjay Agarwala
- Chief of Surgery and Director Professional Services, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| | - Mayank Vijayvargiya
- Junior Consultant, Department of Orthopedics, P.D Hinduja Hospital and Medical Research Centre, 400016 Mumbai, India
| |
Collapse
|
3
|
Abstract
BACKGROUND This study aimed to examine the major reasons for total hip arthroplasty (THA) failure and temporal patterns in THA revisions. METHODS A retrospective chart review was conducted on 535 revisions performed on 444 THAs from January 2010 to May 2019 at our institution. RESULTS The average time to revision THA was 8.51 ± 8.38 years, with 136 cases (30.9%) occurring within 2 years after primary THA. The major mechanisms of failure that resulted in revision surgery were mechanical failure (162, 36.5%), metallosis (95, 21.4%), dislocation or instability (65, 14.6%), periprosthetic fracture (46, 10.4%), infection (44, 9.9%), hematoma or poor wound healing (15, 3.4%), and pain or other (17, 3.8%). CONCLUSION Based on our institutional experience over the past decade, mechanical failure without dislocation, metallosis, dislocation, periprosthetic fracture, and infection are typical reasons patients present for primary THA revision. Revisions within 2 years after primary THA are more likely to be the result of infection and periprosthetic fracture. Mechanical failure is the most common reason for revision THA overall, and mechanical failure and metallosis are more likely to be the reason revision is necessary 2 or more years after primary THA.
Collapse
|
4
|
Pozzuoli A, Berizzi A, Crimì A, Belluzzi E, Frigo AC, Conti GD, Nicolli A, Trevisan A, Biz C, Ruggieri P. Metal Ion Release, Clinical and Radiological Outcomes in Large Diameter Metal-on-Metal Total Hip Arthroplasty at Long-Term Follow-Up. Diagnostics (Basel) 2020; 10:diagnostics10110941. [PMID: 33198180 PMCID: PMC7698262 DOI: 10.3390/diagnostics10110941] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 02/08/2023] Open
Abstract
Total hip arthroplasty (THA) with metal-on-metal (MoM) bearings have shown problems of biocompatibility linked to metal ion release at the local level causing an adverse reaction to metal debris (ARMD) and at a systemic level. The aim of this study was to evaluate clinical and radiological outcomes, and metal ion concentrations in the blood and urine of patients who underwent THA with the LIMA Met-Met hip system. Patients with ceramic-on-ceramic (CoC) bearings were included as a control group. In this study, 68 patients were enrolled: 34 with MoM THAs and 34 with CoC THAs. Patients were evaluated clinically (Harris Hip Score, SF-36) and radiologically at a median of 7.4 years after surgery. Whole blood and urinary cobalt and chromium levels were also assessed. Both types of implants were comparable in terms of clinical and functional results. Ion levels were significantly higher in the MoM group compared with CoC group 7 years after surgery. No correlations were found between metal ion levels and patient demographics, functional and radiological outcomes, and prosthesis features. Patient monitoring is thus advised to establish if prosthesis revision is necessary, especially in the case of MoM THA.
Collapse
Affiliation(s)
- Assunta Pozzuoli
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Antonio Berizzi
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Alberto Crimì
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Elisa Belluzzi
- Laboratory of Musculoskeletal Pathology and Oncology, Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy
- Correspondence: (A.P.); (E.B.); Tel.: +39-0498213348 (A.P. & E.B.)
| | - Anna Chiara Frigo
- Epidemiology and Public Health Unit, Department of Cardiac Thoracic Vascular Sciences and Public Health, Biostatistics, University of Padova, Via Loredan 18, 35131 Padova, Italy;
| | - Giorgio De Conti
- Department of Radiology, University Hospital of Padova, Via Giustiniani 2, 35128 Padova, Italy;
| | - Annamaria Nicolli
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Andrea Trevisan
- Laboratory of Industrial Toxicology, Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padova, Via Giustiniani 2, 35128 Padova, Italy; (A.N.); (A.T.)
| | - Carlo Biz
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| | - Pietro Ruggieri
- Orthopaedic and Traumatologic Clinic, Department of Surgery, Oncology and Gastroenterology, University of Padova, Via Giustiniani 3, 35128 Padova, Italy; (A.B.); (A.C.); (C.B.); (P.R.)
| |
Collapse
|
5
|
Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2020; 35:3230-3236.e3. [PMID: 32665157 DOI: 10.1016/j.arth.2020.06.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/10/2020] [Accepted: 06/10/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. METHODS Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. RESULTS Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02). CONCLUSION MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. LEVEL OF EVIDENCE Level II, Prospective Cohort Study.
Collapse
|
6
|
Causes of acromion and scapular spine fractures following reverse shoulder arthroplasty: a retrospective analysis and literature review. INTERNATIONAL ORTHOPAEDICS 2020; 44:2673-2681. [PMID: 32995915 PMCID: PMC7679357 DOI: 10.1007/s00264-020-04813-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 09/15/2020] [Indexed: 12/25/2022]
Abstract
Purpose Fractures of the acromion and the scapular spine are serious complications after reverse total shoulder arthroplasty. They concern about 4 to 5% of the patients and always result in a significant deterioration of shoulder function. Different causes have been taken into consideration, particularly stress or fatigue fractures. The purpose of the present study was to analyse our own cases and to discuss the causes reported in the literature. Methods We reviewed our shoulder arthroplasty registry and the consultation reports of the last ten years. The charts and radiographs of all patients who had a post-operative fracture of the acromion or the scapular spine were carefully examined and the results were compared with those of an age- and gender-matched control group. Results Twelve patients with an average age of 79 years sustained a fracture of the acromion (n = 6) or the scapular spine (n = 6). The time interval between the operation and the fracture averaged 26 months and ranged from three weeks to 70 months. Eight patients (67%) had a trauma. Seven of them reported a fall on the corresponding shoulder and one a heavy blow on the acromion. The four non-traumatic fractures were attributed to poor bone quality. All 12 patients had immediate pain and difficulty to actively elevate the affected arm. The time interval between the fracture and its diagnosis averaged ten weeks (0 to 10 months). At final follow-up, all patients could reach their face and refused further surgery. Two patients rated their result as good, six as acceptable and four as poor. Conclusions Our study cannot support the hypothesis that most acromion and scapular spine fractures after RSA are the result of increased tension in the deltoid or stress fractures. In our series, the majority of the fractures were related to a fall. Implantation of a reverse prosthesis exposes the acromion and makes it more vulnerable to direct trauma. Non-traumatic fractures were associated with poor bone quality.
Collapse
|
7
|
Comparison of Harris Hip Scores and Revision Rates in Metal-on-Metal Versus Non-Metal-on-Metal Total Hip Arthroplasty. J Am Acad Orthop Surg 2020; 28:e422-e426. [PMID: 31415300 DOI: 10.5435/jaaos-d-19-00251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION This study compares functional outcome scores and revision rates between metal-on-metal (MoM) and non-MoM total hip arthroplasty patients. METHODS A cohort of 75 patients who underwent implantation of the same dual modular hip arthroplasty between the years of 2004 and 2010 was enrolled. Patients were subsequently evaluated in 2015 to 2017 for joint revision history and functionality, as measured by the Harris hip score (HHS). Patients requiring a revision arthroplasty were not included in the HHS analysis. RESULTS A total of 49 patients had MoM implants (65.3%), and 26 patients had non-MoM implants (34.8%). At a mean follow-up of 7.6 years, 10.2% (5/49) of MoM prostheses required revision, whereas 3.8% (1/26) of non-MoM prostheses required revision (P = 0.334). The mean HHS in the MoM cohort was 89.8, compared with 88.1 in the non-MoM cohort (P = 0.69). CONCLUSION HHSs were not notably different between cohorts. The MoM cohort had three times as many revisions as the non-MoM cohort, but given the numbers available, this difference did not reach significance. Given the clinical importance of these revision data, further study is warranted to determine survivorship of the MoM versus non-MoM total hip arthroplasty at long-term follow-up.
Collapse
|
8
|
Ray GS, Laaksonen I, Galea VP, Madanat R, Muratoglu O, Malchau H. Obesity is not associated with hip failure in patients with articular surface replacement of the hip. Hip Int 2020; 30:78-86. [PMID: 30821180 DOI: 10.1177/1120700019828705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Our main aim was to investigate whether obese patients were at increased risk of elevated metal ion levels and/or adverse local tissue reaction (ALTR) after being treated with articular surface replacement (ASR) hip arthroplasty. METHODS This study included 360 patients who underwent metal-on-metal (MoM) hip resurfacing (HRA) or total hip arthroplasty (THA). 95 patients (26%) were underweight/normal weight (BMI < 25 kg/m2), 139 (39%) were overweight (BMI 25-30 kg/m2), and 126 (36%) were obese (BMI ⩾ 30 kg/m2). Blood metal ion levels and patient-reported outcome measures (PROMs) were obtained, and a sub-cohort of 85 patients had MARS MRI performed. Logistic regression analyses were used to assess the associations between obesity and metal ions, as well as ALTR. RESULTS BMI was not associated with either elevated metal ion levels or ALTR. In HRA patients, female gender (OR 3.0; p = 0.019) and pain (OR 2.3; p = 0.046) were associated with elevated Co levels. Female patients had increased risk of elevated Cr levels (OR 3.0; p = 0.02). In THA patients, female gender (OR 2.2; p = 0.004) and VAS satisfaction (OR 2.1; p = 0.01) were associated with elevated Co levels. Female gender (OR 3.6; p = 0.001) and time from surgery (OR 1.4; p = 0.005) were associated with Cr levels. In the sub-cohort, ALTR was associated with Co levels (OR 16.1; p = 0.002) in HRA patients. CONCLUSION Patients with BMI ⩾ 30 kg/m2 present no increased risk for elevated metal ion levels or development of ALTR.
Collapse
Affiliation(s)
- Gabrielle S Ray
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Inari Laaksonen
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Vincent P Galea
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA
| | - Rami Madanat
- Harvard Medical School, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA.,Harvard Medical School, Department of Orthopaedic Surgery, Boston, MA, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston, MA, USA.,Harvard Medical School, Department of Orthopaedic Surgery, Boston, MA, USA
| |
Collapse
|
9
|
Stone AH, King PJ. Simultaneous combined retroperitoneal and posterior hip approach for the treatment of iliopsoas abscess with extension to a metal-on-metal prosthetic hip joint. Arthroplast Today 2019; 5:269-275. [PMID: 31516963 PMCID: PMC6728528 DOI: 10.1016/j.artd.2019.06.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 06/04/2019] [Accepted: 06/05/2019] [Indexed: 12/27/2022] Open
Abstract
Iliopsoas abscess is an uncommon entity that has only rarely been associated with periprosthetic hip infection; to our knowledge, these are the first reported cases in patients with metal-on-metal (MoM) hip arthroplasty. We report 2 cases of iliopsoas abscess and concomitant periprosthetic hip infection in patients with a history of MoM hip arthroplasty. Case 1 presented with an acute infection 18 months after revision total hip arthroplasty (THA) for instability and adverse local tissue reaction after MoM THA. Case 2 presented with an acute infection in a previously well-functioning MoM THA. Both cases were treated with combined hip and retroperitoneal approaches and required more aggressive and longer treatment than is typical for periprosthetic infection, but ultimately resulted in successful revision THAs. We outline the treatment of these 2 patients and review the previously reported literature.
Collapse
Affiliation(s)
- Andrea H Stone
- Department of Surgical Research, Anne Arundel Medical Center, Annapolis, MD, USA
| | - Paul J King
- Center for Joint Replacement, Anne Arundel Medical Center, Annapolis, MD, USA
| |
Collapse
|
10
|
The 10-year outcomes of the ASR XL Acetabular System: a single-center experience from China. J Orthop Surg Res 2019; 14:154. [PMID: 31126346 PMCID: PMC6534829 DOI: 10.1186/s13018-019-1173-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Accepted: 04/29/2019] [Indexed: 11/25/2022] Open
Abstract
Background The revision rate of articular surface replacement (ASR) implants continues to rise in China because of metal debris. However, there are few reports on the clinical results of ASR implants with prolonged follow-up time in China. This study investigated the clinical outcomes and the risk factors of revision surgery in patients with ASR implants. Methods In total, 74 patients (74 hips) who underwent primary total hip arthroplasty (THA) with ASR implants over the past 4 to 10 years were retrospectively analyzed. Relevant clinical, radiographic, and biochemical data were examined. Results The average follow-up time was 88.46 (range 23–114) months, and the ASR implants of 18 hips (24.3%) were revised. Patients who received revision surgery had worse joint function with significantly lower Harris Hip Score and Western Ontario and McMaster Universities index than non-revision patients (61.11 ± 6.68 vs 85.30 ± 9.16, p < 0.001; 61.00 ± 3.83 vs 79.04 ± 14.49, p < 0.001; respectively). Higher acetabular abduction angle and serum Co and Cr concentration were significantly relevant to worse joint function as measured by HSS (p = 0.018, 0.009, 0.043, respectively). ROC curve analysis was applied to categorize the optimal cutoff values of acetabular abduction angle and serum Cr and Co concentration for revision surgery, which were settled as 47.80°, 98.44 μg/L, and 6.95 μg/L, respectively. Overall survival of the prostheses with high acetabular abduction angle (> 47.80°, HR = 70.145, 95% CI 1.558–3158.213, p = 0.029), high serum Cr concentration (98.44 μg/L, HR = 58.956, 95% CI 1.294–2685.203, p = 0.036), and high serum Co concentration (> 6.95 μg/L, HR = 179.511, 95% CI 2.360–13656.941, p = 0.019) decreased significantly than the lower groups. Conclusions Evaluation of the DePuy ASR XL articulation demonstrated increased rates of revision following a longer follow-up period. High acetabular abduction angle and serum Cr and Co concentration correlated with worse clinical outcomes and high revision rate. Therefore, we advocate that patients with DePuy ASR XL implants be followed up more closely than those with other implants, especially with high acetabular abduction angle and serum Cr or Co concentration.
Collapse
|
11
|
Kovochich M, Finley BL, Novick R, Monnot AD, Donovan E, Unice KM, Fung ES, Fung D, Paustenbach DJ. Understanding outcomes and toxicological aspects of second generation metal-on-metal hip implants: a state-of-the-art review. Crit Rev Toxicol 2019; 48:853-901. [DOI: 10.1080/10408444.2018.1563048] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
12
|
What Is the Clinical Presentation of Adverse Local Tissue Reaction in Metal-on-metal Hip Arthroplasty? An MRI Study. Clin Orthop Relat Res 2019; 477:353-360. [PMID: 30794223 PMCID: PMC6370095 DOI: 10.1097/corr.0000000000000393] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Adverse local tissue reaction (ALTR) is not only a prominent cause of metal-on-metal (MoM) implant revision, but may also compromise the result of revision surgery. Patients treated with MoM arthroplasty and subsequently revised as a result of ALTR have been shown to experience worse patient-reported outcomes, inferior survivorship, and more complications when compared with patients receiving MoM implants who were revised for reasons other than ALTR. There is conflicting evidence as to whether the presence of symptoms is associated with ALTR in patients with MoM implants. Blood metal ions are associated with ALTR, but a consensus on appropriate thresholds associated with ALTR risk is lacking. QUESTIONS/PURPOSES (1) Was the presence of symptoms as measured by patient-reported outcome measures associated with ALTR presence and severity as noted on metal artifact reduction sequence (MARS)-MRI in patients treated with one design of MoM THA or hip resurfacing arthroplasty (HRA)? (2) Could reliable thresholds for blood metal ion levels be determined that were associated with ALTR presence on MARS-MRI? METHODS This retrospective study presents a secondary analysis of data drawn from a prospective, international, multicenter study of the recalled Articular Surface Replacement (ASR) hip system. This larger study aims to identify risk factors for revision and provide followup guidelines for the many unrevised ASR patients. A total of 1721 patients were enrolled from 16 centers in six countries after the device was recalled and are followed annually for 5 years. In the present analysis, data from the enrollment visit (mean time from index surgery, 7.5 years; SD 3.5 years) were considered. Only patients from two centers conducting MARS-MRI on all patients regardless of clinical presentation as a standard of care were included to avoid selection bias. A total of 327 unilateral patients fulfilled our inclusion criteria (90% of those eligible). The level of symptoms was systematically determined using the Harris hip score and a visual analog scale for pain, and whole blood metal ion levels were collected from all patients. MARS-MRIs were analyzed by a single reader for ALTR presence (Anderson classification), diameter, and synovial thickness. A validation series of 35 MARS-MRIs indicated excellent intrareader reproducibility of the evaluations (intraclass correlation = 0.82) and substantial agreement (κ coefficient = 0.64) was achieved between the MARS-MRI reader and a musculoskeletal radiologist with > 10 years of experience with MARS-MRI. Binary logistic regression was used to determine variables independently associated with ALTR. Receiver operator characteristic curves were used to determine sensitive and specific cut points for cobalt and chromium. RESULTS After controlling for confounding variables, presence of symptoms was determined to be a risk factor for ALTR (odds ratio, 2.9; p = 0.007) in patients treated with ASR MoM THA. Moreover, among patients undergoing ASR MoM THA with ALTR, synovial thickness correlated with symptomaticity (p = 0.030). For patients undergoing ASR MoM HRA, we found no association between symptoms and ALTR prevalence or severity. A cobalt cutoff of 3.2 parts per billion (ppb) was associated with increased risk of ALTR (p < 0.001; sensitivity, 68%; specificity, 71%) in ASR MoM THA. In patients with ASR MoM HRA, a cobalt threshold of 2.9 ppb was indicative of ALTR (p < 0.001; sensitivity, 79%; specificity, 69%). CONCLUSIONS The risk factors identified in the current study may be used to stratify patients receiving MoM implants in terms of ALTR risk. We found that symptoms are associated with an increased likelihood of ALTR presence in ASR MoM THA and that cobalt ion level is associated with ALTR in ASR MoM THA as well as ASR MoM HRA. Importantly, MoM HRA followup protocols that exempt asymptomatic patients from annual followup are not justified because asymptomatic patients are no less likely to have ALTR than symptomatic patients. Blood metal ion levels may reliably be used to screen patients undergoing MoM HRA. For patients undergoing MoM THA, a combination of symptom state and blood metal ion levels may be used to determine ALTR risk. LEVEL OF EVIDENCE Level III, diagnostic study.
Collapse
|
13
|
Hjorth MH, Mechlenburg I, Soballe K, Roemer L, Stilling M. The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations. J Orthop Translat 2018; 18:74-83. [PMID: 31508310 PMCID: PMC6718878 DOI: 10.1016/j.jot.2018.11.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 11/09/2018] [Accepted: 11/19/2018] [Indexed: 12/22/2022] Open
Abstract
Purpose Young and physically active patients have mainly received metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, the correlation between daily physical activity (PA) levels, serum-ion concentrations of chromium and cobalt and pseudotumours formation of patients who underwent MoM THA/RHA is insufficiently explored. Methods Ninety-nine patients with 134 hip articulations, 71 MoM THA/RHA and 63 MoP THA participated in a cross-sectional study at XXX University Hospital, Denmark, at mean 7.3 (range: 0.4–21.7) years after surgery. Patients' daily PA was monitored during a two-week period using a triaxial accelerometer. Metal artefact reduction sequence magnetic resonance imaging scans, estimation of serum-ion concentrations of chromium and cobalt and the Copenhagen Hip and Groin Outcome Score (HAGOS) questionnaire were completed on Day 14. Results Patients with a pseudotumour who underwent MoM THA/RHA had a higher average cadence of median 101.4 [interquartile range (IQR: 95.5–105)] steps/min than patients without a pseudotumor, median 96.7 (IQR: 92.2–103) steps/min (p = 0.02). Serum-ion concentrations of chromium and cobalt were higher in patients with a pseudotumour who underwent MoM THA/RHA, median 2.57 (IQR: 1.4–3.4) μg/L and 1.80 (IQR: 1.2–2.6) μg/L, respectively, than in patients without a pseudotumour, median 1.85 (IQR: 1.1–3.2) μg/L and 1.34 (IQR: 0.9–2.2) μg/L in MoM THA/RHA (p = 0.04 and p = 0.03). There was no statistical difference in these parameters between patients with and without a pseudotumour who underwent MoP THA. Daily PA levels of patients who underwent MoM THA/RHA were significantly correlated with serum-ion concentrations of chromium (p = 0.0002, r = 0.44) and cobalt (p = 0.005, r = 0.34), whereas no correlations were seen among patients who underwent MoP THA (p > 0.12). Conclusion The daily PA level of patients who underwent MoM THA/RHA influences the serum-ion concentrations of chromium and cobalt and the risk of pseudotumour formation. Translational potential of this article Results of this article add important knowledge on potential recommendations of prosthesis selection for patients with a high level of physical activity.
Collapse
Affiliation(s)
- Mette Holm Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Tage-Hansens Gade 2, 8000 Aarhus C, Denmark.,Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 82, 8200 Aarhus N, Denmark
| |
Collapse
|
14
|
Mid- to long-term results of resurfacing hip arthroplasty in Japanese patients: a comparison of osteoarthritic vs non-osteoarthritic patients. J Artif Organs 2018; 22:77-83. [PMID: 30370465 DOI: 10.1007/s10047-018-1077-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Accepted: 08/26/2018] [Indexed: 12/12/2022]
Abstract
Past reports showed good mid-term results of RHA for Japanese patients. However, few reports have compared the mid- to long-term results for RHA in Japanese patients with and without osteoarthritis. Therefore, this study investigated the mid- to long-term results of RHA in Japanese patients with osteoarthritis compared to those without. We conducted a retrospective review of a consecutive series of 92 hips in 80 patients (59 men and 21 women). The minimum follow-up period was 5 years. The JOA hip scoring system was used to clinically evaluate hip function. In the radiological assessment, stem-shaft angle, inclination of the acetabular component, postoperative complications, and adverse reactions around RHA were evaluated. The 10-year survival rate using the Kaplan-Meier method was investigated to compare patients with and without osteoarthritis. A significant difference was observed between the preoperative and postoperative JOA hip scores of either group. Also, the radiological assessment revealed no significant changes in either group. All three revision THAs were performed on patients in the only non-osteoarthritis group. In the osteoarthritis group, the 10-year survival rate was 94% (95% CI 81.8-100) in males and 100% (95% CI 100) for females; in the non-osteoarthritis group, the rate was 80% (95% CI 55.1-100) in males and 66.7% (95% CI 13.3-100) for females. In conclusion, this study showed good mid- to long-term clinical results for young Japanese osteoarthritis patients, with less satisfactory mid- to long-term results in patients without osteoarthritis.
Collapse
|
15
|
Hjorth MH, Mechlenburg I, Soballe K, Jakobsen SS, Roemer L, Stilling M. Physical Activity Is Associated With the Level of Chromium but Not With Changes in Pseudotumor Size in Patients With Metal-on-Metal Hip Arthroplasty. J Arthroplasty 2018; 33:2932-2939. [PMID: 29807790 DOI: 10.1016/j.arth.2018.04.039] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 04/17/2018] [Accepted: 04/23/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA) were previously considered an excellent option for young and physically active patients. However, the relationship between MoM THA/RHA patients' daily physical activity (PA), metal ion measurements of chromium and cobalt, and pseudotumor dynamic is insufficiently explored. METHODS One hundred eleven patients with 148 hip articulations, 77 MoM THA/RHA and 71 MoP THA, participated in a prospective cohort study, with 5 cross-sectional analyses during a 1-year follow-up. Baseline follow-up was at mean 7.1 (range: 0.2-21.5) years postoperative. At baseline and every 3 months thereafter, patients' daily PA was monitored during a 2-week period using a triaxial accelerometer, and next metal artifact reducing sequence magnetic resonance imaging scans, metal ion measurements of chromium and cobalt, and the Copenhagen Hip and Groin Outcome Score questionnaire were completed. RESULTS We found a statistically significant relationship between daily PA and metal ion measurements of chromium at all follow-ups in MoM THA/RHA patients (P ≤ .03) but not in MoP THA patients (P > .35). Patients' daily PA was not related to changes in pseudotumor size at any follow-up (P > .30). Ten of 26 (38%) pseudotumors in MoM THA/RHA and 8 of 29 (28%) pseudotumors in MoP THA changed classification according to the Anderson grading. No pseudotumors transformed in appearance or changed anatomical location. CONCLUSION The daily PA of MoM THA/RHA patients is associated with metal ion measurements of chromium but not with changes in pseudotumor size. This is new and important knowledge, which may be useful for hip surgeons in recommendation and monitoration of the consequences of PA in active patients with MoM THA/RHA.
Collapse
Affiliation(s)
- Mette H Hjorth
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Inger Mechlenburg
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Kjeld Soballe
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lone Roemer
- Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
16
|
Higher Prevalence of Mixed or Solid Pseudotumors in Metal-on-Polyethylene Total Hip Arthroplasty Compared With Metal-on-Metal Total Hip Arthroplasty and Resurfacing Hip Arthroplasty. J Arthroplasty 2018. [PMID: 29526334 DOI: 10.1016/j.arth.2018.02.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Pseudotumors are a common finding in metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, information on pseudotumors in metal-on-polyethylene (MoP) THA is limited. METHODS One hundred eleven patients with 148 hip articulations-30 MoM THA, 47 MoM RHA, and 71 MoP THA-participated in a cross-sectional study at mean 7.1 (range: 0.2-21.5) years postoperatively. Patients were evaluated with metal artifact reducing sequence magnetic resonance imaging, measurements of metal ions, clinical scores of Harris Hip Score, Oxford Hip Score, the Copenhagen Hip and Groin Outcome Score, and conventional radiographs. RESULTS Pseudotumors were present in 13 of 30 (43%) MoM THA, 13 of 47 (28%) MoM RHA, and 29 of 71 (41%) MoP THA patients, which was a similar prevalence (P = .10). The prevalence of mixed or solid pseudotumors was significantly higher in patients with MoP THA (n = 10) compared to MoM THA (n = 3) and MoM THA (n = 0), (P = .01). Hips with a mixed or solid pseudotumor had significantly poorer scores of Harris Hip Score (P = .01) and OHS (P = .002) and higher metal ion levels of cobalt (P = .0009) compared to hips without a pseudotumor or with a cystic pseudotumor. CONCLUSION Pseudotumors have primarily been associated with MoM hip articulations, but we found a similar pseudotumor prevalence in MoP THA, which is the most common bearing worldwide. Mixed or solid pseudotumors were more often seen in MoP THA compared with MoM hip articulations, and patients with a mixed or solid pseudotumor had poorer clinical scores and higher metal ion levels than patients without a pseudotumor or with a cystic pseudotumor.
Collapse
|
17
|
Markel DC, Bergum C, Flynn J, Jackson N, Bou-Akl T, Ren W. Relationship of Blood Metal Ion Levels and Leukocyte Profiles in Patients With Articular Surface Replacement Metal-on-Metal Hip Replacement. Orthopedics 2018; 41:e424-e431. [PMID: 29708567 DOI: 10.3928/01477447-20180409-02] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2017] [Accepted: 01/22/2018] [Indexed: 02/03/2023]
Abstract
The purpose of this study was to compare blood leukocyte profiles and metal ion concentrations between hip resurfacing arthroplasty (articular surface replacement) patients with and without revision. A total of 25 articular surface replacement patients were recruited (10 with stable implants and 15 undergoing revision). Blood concentrations of chromium (Cr) and cobalt (Co) were measured. Flow cytometry was used to quantify the subpopulations of leukocytes, including CD14+ monocytes, CD16+ monocytes, CD3+ T-lymphocytes, CD19+ B-lymphocytes, CD4+ helper T-cells, and CD45+RA memory vs naïve T-cells. Patients undergoing revision had higher blood Co (mean, 10.85 µg/L) and Cr (mean, 3.19 µg/L) levels than patients with stable implants (mean Co, 3.06 µg/L; mean Cr, 1.07 µg/L) (P<.05). The number of CD4+ helper T-cells was higher in patients with stable implants (mean, 842±311 cells/µL) than in patients undergoing revision (mean, 591±208 cells/µL) (P<.05). There was a significant association between total metal ion levels (Co+Cr) and the number of CD14+ monocytes (P=.045) and inflammatory CD16+ monocytes (P=.046). The authors observed that the increase in blood metal ions was associated with an increase in CD16+ monocytes. They believe that continued analysis of blood leukocyte profiles may be helpful in defining differences among failed articular surface replacement, stable articular surface replacement, and failed metal-on-polyethylene implants. [Orthopedics. 2018; 41(3):e424-e431.].
Collapse
|
18
|
Matharu GS, Judge A, Eskelinen A, Murray DW, Pandit HG. What is appropriate surveillance for metal-on-metal hip arthroplasty patients? Acta Orthop 2018; 89:29-39. [PMID: 29105547 PMCID: PMC5810829 DOI: 10.1080/17453674.2017.1398011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory authorities recommending regular surveillance, even for asymptomatic individuals. However, these recommendations are not evidence-based and are very costly. The rapidly evolving evidence base requires an update regarding the investigation and management of MoMHA patients. This article is the first of 2 (the second article in this series will consider the threshold for performing revision, and the outcomes following ARMD revision surgery: Matharu et al., Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update. Acta Orthop 2018; in press), and considers the various investigative modalities used during surveillance, with specific focus on blood metal ion sampling and cross-sectional imaging. No single investigation can universally be used during MoMHA patient surveillance. Recent studies have now provided important information on interpreting blood metal ions (effective in identifying patients at low risk of problems), clarifying the roles of cross-sectional imaging (reserve combined ultrasound and MARS-MRI for complex cases), and providing parameters to safely exclude many asymptomatic patients from regular surveillance. This information will be useful when designing future surveillance protocols for MoMHA patients.
Collapse
Affiliation(s)
- Gulraj S Matharu
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK;,Correspondence:
| | - Andrew Judge
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | | | - David W Murray
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| | - Hemant G Pandit
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences University of Oxford, Nuffield Orthopaedic Centre, Oxford, UK
| |
Collapse
|
19
|
Risk factors for mid-term revision surgery in patients with articular surface replacement total hip arthroplasty. Hip Int 2018; 28:44-49. [PMID: 28574125 DOI: 10.5301/hipint.5000524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION This study assessed the associations between gender and implant survival, as well as adverse local tissue reaction (ALTR), in patients with articular surface replacement (ASR) XL total hip arthroplasty (THA). Secondly, we sought to report the differences between genders in metal ion levels and patient reported outcome measures (PROMs) in these patients. METHODS 563 unilateral ASR XL THA patients were enrolled in a multicentre follow-up study at a mean of 6.4 years after index surgery. All patients had blood metal ion levels and PROMs obtained annually, and a valid anteroposterior pelvis radiograph. A sub-set of patients from a single centre had annual MRI performed and were analysed for the presence of moderate-to-severe ALTR. RESULTS 60 hips (11%) were revised during the study period. The only variables found to be associated with revision surgery in patients with unilateral THA were VAS pain (hazard ratio [HR], 1.35; p<0.001) and elevated cobalt metal ion levels (HR, 1.05; p<0.001). No variables assessed were found to be associated with prevalence of ALTR. Chromium concentrations were greater in female patients than males, while cobalt levels were similar between genders. Males reported higher HHS, EQ-5D and UCLA scores than females. CONCLUSIONS Both males and females with metal-on-metal THA implants should be followed with equal vigilance as gender does not appear to be associated with poor outcomes, such as revision surgery and presence of ALTR.
Collapse
|
20
|
Granchi D, Savarino LM, Ciapetti G, Baldini N. Biological effects of metal degradation in hip arthroplasties. Crit Rev Toxicol 2017; 48:170-193. [PMID: 29130357 DOI: 10.1080/10408444.2017.1392927] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Metals and metal alloys are the most used materials in orthopedic implants. The focus is on total hip arthroplasty (THA) that, though well tolerated, may be associated with local and remote adverse effects in the medium-long term. This review aims to summarize data on the biological consequences of the metal implant degradation that have been attributed predominantly to metal-on-metal (MoM) THA. Local responses to metals consist of a broad clinical spectrum ranging from small asymptomatic tissue lesions to severe destruction of bone and soft tissues, which are designated as metallosis, adverse reactions to metal debris (ARMD), aseptic lymphocytic vasculitis associated lesion (ALVAL), and pseudotumors. In addition, the dissemination of metal particles and ions throughout the body has been associated with systemic adverse effects, including organ toxicity, cancerogenesis, teratogenicity, and immunotoxicity. As proved by the multitude of studies in this field, metal degradation may increase safety issues associated with THA, especially with MoM hip systems. Data collection regarding local, systemic and long-term effects plays an essential role to better define any safety risks and to generate scientifically based recommendations.
Collapse
Affiliation(s)
- Donatella Granchi
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Lucia Maria Savarino
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Gabriela Ciapetti
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy
| | - Nicola Baldini
- a Orthopedic Pathophysiology and Regenerative Medicine Unit , Rizzoli Orthopedic Institute , Bologna , Italy.,b Department of Biomedical and Neuromotor Science , University of Bologna , Bologna , Italy
| |
Collapse
|
21
|
Carlson BC, Bryan AJ, Carrillo-Villamizar NT, Sierra RJ. The Utility of Metal Ion Trends in Predicting Revision in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2017; 32:S214-S219. [PMID: 28320566 DOI: 10.1016/j.arth.2017.02.031] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Revised: 02/03/2017] [Accepted: 02/11/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There is a paucity of data examining metal ion levels over time. METHODS We retrospectively reviewed 59 patients (69 hips) with an articular surface replacement total hip arthroplasty. We reviewed prerevision cobalt and chromium concentrations over time. RESULTS Seventy-one percent of patients who were revised and had multiple ion measurements (12/17) demonstrated increasing cobalt ion levels or elevated ion levels over time. There was a trend toward an elevated risk of revision for increasing cobalt and chromium levels starting at 12 and 4 ppb, respectively; this was significant for chromium levels above 7 ppb (hazard ratio 22.35, P = .001). Similarly, there was a trend toward an elevated risk of pseudotumor formation for increasing cobalt and chromium levels starting at 5 and 2.5 ppb, respectively; this was significant for cobalt levels above 7 ppb (hazard ratio 6.88, P = .027). CONCLUSION In this paper, cobalt and chromium levels levels above 5 and 2.5 ppb started to demonstrate an increased risk of ARMD, and should be considered as a lower cutoff for discussion with patients about the potential for future revision.
Collapse
Affiliation(s)
- Bayard C Carlson
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Andrew J Bryan
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
22
|
Ultrasound findings in asymptomatic patients with modular metal on metal total hip arthroplasty. Skeletal Radiol 2017; 46:641-649. [PMID: 28204856 DOI: 10.1007/s00256-017-2592-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2016] [Revised: 01/24/2017] [Accepted: 01/27/2017] [Indexed: 02/08/2023]
Abstract
OBJECTIVE The use of metal-on-metal and modular total hip arthroplasty is associated with potentially serious local and systemic complications. The primary aim of this study was to identify the prevalence of a pseudotumor in asymptomatic patients with a particular metal-on-metal hip prosthesis after a minimum follow-up of 5 years using ultrasound evaluation. A secondary purpose was to identify associations between the presence of pseudotumor and serum metal ion levels following implantation. METHODS We prospectively evaluated data collected from 36 asymptomatic patients who underwent implantation of a Profemur Z metal-on-metal total hip arthroplasty from January 2004 to January 2010. Serum metal ion levels were collected in 2012 and 2015. Hip ultrasounds were performed in 2015. RESULTS Pseudotumors were found in 7/36 patients (19.4%). The average pseudotumor size measured 38.2 cm3 (range 7.35 cm3-130.81 cm3). Elevated metal ion levels were found in all patients at all time points. No statistical correlation was found between the presence of pseudotumor and patient age, age of the implant, component design, and any of the serum metal ion levels or ratios. CONCLUSIONS One in every five asymptomatic patients with metal-on-metal implants was found to have a periarticular pseudotumor. There was no dose-dependent relationship found between elevated serum metal ion levels and the development of a pseudotumor. Our findings suggest that in patients with known elevated metal ion levels, continued monitoring of ion levels may not be a reliable predictor of pseudotumor formation, and ultrasound surveillance can and should be routinely used to document the presence and progression of pseudotumor.
Collapse
|
23
|
Maurer-Ertl W, Friesenbichler J, Holzer LA, Leitner L, Ogris K, Maier M, Leithner A. Recall of the ASR XL Head and Hip Resurfacing Systems. Orthopedics 2017; 40:e340-e347. [PMID: 27992643 DOI: 10.3928/01477447-20161213-04] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2016] [Accepted: 10/31/2016] [Indexed: 02/03/2023]
Abstract
At the beginning of the 21st century, use of large-diameter, metal-on-metal devices was a popular procedure for hip replacement in young and physically active patients; however, within a few years, the number of revisions increased, resulting in a worldwide recall for the articular surface replacement (ASR) system. Complication rates for the ASR devices implanted at the authors' department are reported, with revision rates of 32% and 30% in the ASR XL Head and ASR Resurfacing groups, respectively. Reasons for revision surgery were serum metal ion elevation, luxation or subluxation, aseptic loosening, soft tissue compromise (adverse reactions to metal debris [ARMD]), and infection. The calculated implant survival for the ASR XL Head system and the ASR Resurfacing device (DePuy Orthopaedics Inc, Warsaw, Indiana) in the current series was 79% and 90%, respectively, at 60 months. Symptomatic patients with metal-on-metal devices, with or without elevated metal ion concentrations, should undergo cross sectional imaging to exclude ARMD. In cases of increased metal ion concentrations, local pain, or ARMD, revision surgery has to be evaluated. In the future, closer monitoring of new implants is needed to prevent high failure rates, as seen with the ASR design. Furthermore, the withdrawal of the device highlights the importance of national implant registries. [Orthopedics. 2017; 40(2):e340-e347.].
Collapse
|
24
|
Sensitivity and Specificity of Metal Ion Levels in Predicting "Pseudotumors" due to Taper Corrosion in Patients With Dual Taper Modular Total Hip Arthroplasty. J Arthroplasty 2017; 32:996-1000. [PMID: 27776907 DOI: 10.1016/j.arth.2016.08.040] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 08/28/2016] [Accepted: 08/29/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Currently, no serum metal ion threshold exists to identify adverse tissue reactions in total hip arthroplasty (THA) patients with taper corrosion. Our study aims to investigate the sensitivity and specificity of serum metal ions in detecting taper corrosion related pseudotumors in patients with dual taper modular THA. METHODS A total of 148 patients with dual taper modular THA were investigated: (1) 90 patients with pseudotumors detected with metal artifact reduction sequence-magnetic resonance imaging (MARS-MRI) and (2) 58 patients without pseudotumors on MARS-MRI. Receiver operating characteristic curves were constructed to determine the sensitivity and specificity using different metal ion thresholds. The severity of intraoperative tissue damage was correlated with preoperative metal ion levels. RESULTS Pseudotumor was associated with higher cobalt (5.0 μg/L vs 3.7 μg/L, P < .01) and Co/Cr ratio (6.0 vs 3.7, P < .01). The sensitivity and specificity for cobalt level of 2.8 μg/L and Co/Cr ratio of 3.8 in detecting taper corrosion-related pseudotumors on MARS-MRI was 88% and 32% and 70% and 50%, respectively. Higher intraoperative tissue damage grades demonstrated significantly higher Co/Cr ratios (8.6 vs 3.4, P = .03). CONCLUSION Although metal ion levels alone should not be relied on as the sole parameter to determine revision surgery, cobalt level >2.8 μg/L and the Co/Cr ratio >3.8 are useful clinical diagnostic adjuncts in the systematic clinical evaluation for taper corrosion-related adverse tissue reactions in patients with dual modular taper THA.
Collapse
|
25
|
Gillam MH, Pratt NL, Inacio MCS, Roughead EE, Shakib S, Nicholls SJ, Graves SE. Heart failure after conventional metal-on-metal hip replacements. Acta Orthop 2017; 88:2-9. [PMID: 27759468 PMCID: PMC5251259 DOI: 10.1080/17453674.2016.1246276] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - It is unclear whether metal particles and ions produced by mechanical wear and corrosion of hip prostheses with metal-on-metal (MoM) bearings have systemic adverse effects on health. We compared the risk of heart failure in patients with conventional MoM total hip arthroplasty (THA) and in those with metal-on-polyethylene (MoP) THA. Patients and methods - We conducted a retrospective cohort study using data from the Australian Government Department of Veterans' Affairs health claims database on patients who received conventional THA for osteoarthritis between 2004 and 2012. The MoM THAs were classified into groups: Articular Surface Replacement (ASR) XL Acetabular System, other large-head (LH) (> 32 mm) MoM, and small-head (SH) (≤ 32 mm) MoM. The primary outcome was hospitalization for heart failure after THA. Results - 4,019 patients with no history of heart failure were included (56% women). Men with an ASR XL THA had a higher rate of hospitalization for heart failure than men with MoP THA (hazard ratio (HR) = 3.2, 95% CI: 1.6-6.5). No statistically significant difference in the rate of heart failure was found with the other LH MoM or SH MoM compared to MoP in men. There was no statistically significant difference in heart failure rate between exposure groups in women. Interpretation - An association between ASR XL and hospitalization for heart failure was found in men. While causality between ASR XL and heart failure could not be established in this study, it highlights an urgent need for further studies to investigate the possibility of systemic effects associated with MoM THA.
Collapse
Affiliation(s)
- Marianne H Gillam
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia,Correspondence:
| | - Nicole L Pratt
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Maria C S Inacio
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Elizabeth E Roughead
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Sepehr Shakib
- Department of Clinical Pharmacology, School of Medicine, University of Adelaide
| | - Stephen J Nicholls
- Department of Medicine, University of Adelaide and South Australian Health and Medical Research Institute, University of Adelaide
| | - Stephen E Graves
- Flinders University School of Medicine, Flinders University, Adelaide and Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, Australia
| |
Collapse
|
26
|
Outcomes of the Recalled Articular Surface Replacement Metal-on-Metal Hip Implant System: A Systematic Review. J Arthroplasty 2017; 32:341-346. [PMID: 27546469 DOI: 10.1016/j.arth.2016.06.060] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2016] [Revised: 06/05/2016] [Accepted: 06/27/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The aim of this review was to synthesize the main findings of clinical studies that have evaluated outcomes of the articular surface replacement (ASR) Hip System. METHODS We performed a systematic literature search to identify all articles published between January 2008 and June 2015 that included ASR hip resurfacing arthroplasty (ASR HRA) or ASR total hip arthroplasty (ASR XL THA) outcomes according to the PRISMA statement. RESULTS A total of 56 studies were assessed. The prevalence of adverse local tissue reactions (ALTRs) and revision rates were found to be high. ALTR prevalence varied from 12.5% to 69% (mean, 33.5%). Mean revision rate for any reason at 4-year to 7-year follow-up was 13.8% (range, 5.6%-31%) for ASR HRA and 14.5% (range, 0%-37%) for ASR XL THA. Femoral head size <53 mm was found to correlate with higher blood metal ion levels. Femoral head size >44 mm was not associated with higher ALTR prevalence or revision rates in ASR XL THA. High blood metal ion levels (>7 μg/L Co, >7 μg/L Cr) were associated with higher failure rates and bearing-related complications. The role of cup positioning was found to be controversial. CONCLUSION ALTR prevalence and failure rates were high. High blood metal ion levels were a risk factor for ALTR and failure. Surprisingly, the role of cup positioning and large femoral head size in ASR XL THA were controversial. These findings should be considered in the clinical follow-up and risk stratification of patients with the ASR Hip System.
Collapse
|
27
|
Hasegawa M, Naito Y, Yamaguchi T, Miyazaki S, Wakabayashi H, Sudo A. Factors associated with symptomatic pseudotumors following metal-on-metal total hip arthroplasty. BMC Musculoskelet Disord 2016; 17:456. [PMID: 27821101 PMCID: PMC5100170 DOI: 10.1186/s12891-016-1317-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 11/01/2016] [Indexed: 01/07/2023] Open
Abstract
Background Pseudotumors associated with metal-on-metal hips can be symptomatic or asymptomatic. The purpose of this study was to identify the characteristics of pseudotumors associated with pain. Methods A total of 239 large-diameter, metal-on-metal total hip arthroplasties (THAs) were performed in 222 patients. Screening for pseudotumors was performed using magnetic resonance imaging (MRI) in all patients who underwent metal-on-metal THA, and 57 patients with 62 affected hips showed pseudotumors. There were 45 women with 49 hips and 12 men with 13 hips affected, with a mean age of 64 years and a mean body mass index (BMI) of 23.9 kg/m2. Sixteen hips had symptomatic pseudotumors with pain, and 46 hips were asymptomatic. Pseudotumor size was determined. The anatomical position of pseudotumors was divided into anterior position and posterolateral position. Types of pseudotumors were divided into two types: cystic type; and mixed solid cystic and solid type without a cystic component. The follow-up study of pseudotumors was determined using MRI in 33 patients. The serum cobalt and chromium ion levels were measured in 38 patients after unilateral THA. Univariate and multivariate analyses were performed comparing symptomatic and asymptomatic patients to identify the characteristics of symptomatic pseudotumors. Results The mean BMI was 25.4 kg/m2 in symptomatic patients and 23.4 kg/m2 in asymptomatic patients; a higher BMI was associated with symptoms (P = 0.036). Symptomatic pseudotumors were significantly larger (three-fold) than asymptomatic pseudotumors (1812 mm2 vs 642 mm2, P = 0.003). Pseudotumors located in the anterior position were associated with symptoms (P = 0.032), and mixed solid cystic and solid type pseudotumors were associated with symptoms (P = 0.007). A multivariate analysis showed significant differences only in size (R2 = 0.298, P = 0.031). No asymptomatic patients with pseudotumors became symptomatic during the follow-up period of MRI evaluation. Conclusion Larger size was a significant factor for pain on multivariate analysis.
Collapse
Affiliation(s)
- Masahiro Hasegawa
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan.
| | - Yohei Naito
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Toshio Yamaguchi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Shinichi Miyazaki
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Hiroki Wakabayashi
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| | - Akihiro Sudo
- Department of Orthopaedic Surgery, Mie University Graduate School of Medicine, 2-174 Edobashi, Tsu City, Mie, 514-8507, Japan
| |
Collapse
|
28
|
van Lingen CP, Zagra LM, Ettema HB, Verheyen CC. Sequelae of large-head metal-on-metal hip arthroplasties: Current status and future prospects. EFORT Open Rev 2016; 1:345-353. [PMID: 28461912 PMCID: PMC5367524 DOI: 10.1302/2058-5241.1.160014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Large-head metal-on-metal (MoM) bearings were re-popularised in the late 1990s with the introduction of modern hip resurfacing (HR), followed closely by large metal head total hip arthroplasty (THA). A worldwide increase in the use of MoM hip arthroplasty subsequently saw a sharp decline, due to serious complications.MoM was rapidly adopted in the early 2000s until medical device alerts were issued by government regulatory agencies and national and international organisations, leading to post-marketing surveillance and discontinuation of these implants.Guidelines for MoM hip implant follow-up differ considerably between regulatory authorities worldwide; this can in part be attributed to missing or conflicting evidence.The authors consider that the use of large-head MoM THA should be discontinued. MoM HR should be approached with caution and, when considered, should be used only in patients who meet all of the recommended selection criteria, which limits its indications considerably.The phased introduction of new prostheses should be mandatory in future. Close monitoring of outcomes and long-term follow-up is also necessary for the introduction of new prostheses. Cite this article: van Lingen CP, Zagra LM, Ettema HB, Verheyen CC. Sequelae of large-head metal-on-metal hip arthroplasties: current status and future prospects. EFORT Open Rev 2016;1:345-353. DOI: 10.1302/2058-5241.1.160014.
Collapse
Affiliation(s)
| | | | - Harmen B. Ettema
- Isala Clinics, Department of Orthopaedic Surgery and Traumatology, Zwolle, The Netherlands
| | - Cees C. Verheyen
- Isala Clinics, Department of Orthopaedic Surgery and Traumatology, Zwolle, The Netherlands
| |
Collapse
|
29
|
Pahuta M, Smolders JM, van Susante JL, Peck J, Kim PR, Beaule PE. Blood metal ion levels are not a useful test for adverse reactions to metal debris: A systematic review and meta-analysis. Bone Joint Res 2016; 5:379-86. [PMID: 27612918 PMCID: PMC5027892 DOI: 10.1302/2046-3758.59.bjr-2016-0027.r1] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 05/19/2016] [Indexed: 12/12/2022] Open
Abstract
Objectives Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs. Methods We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model. Results Our literature search returned 575 unique articles; only six met inclusion criteria defined a priori. The discriminative capacity of ion tests was homogeneous across studies but that there was substantial cut-point heterogeneity. Our best estimate of the “true” area under curve (AUC) for metal ion testing is 0.615, with a 95% credible interval of 0.480 to 0.735, thus we can state that the probability that metal ion testing is actually clinically useful with an AUC ≥ 0.75 is 1.7%. Conclusion Metal ion levels are not useful as a screening test for identifying high risk patients because ion testing will either lead to a large burden of false positive patients, or otherwise marginally modify the pre-test probability. With the availability of more accurate non-invasive tests, we did not find any evidence for using blood ion levels to diagnose symptomatic patients. Cite this article: M. Pahuta, J. M. Smolders, J. L. van Susante, J. Peck, P. R. Kim, P. E. Beaule. Blood metal ion levels are not a useful test for adverse reactions to metal debris: a systematic review and meta-analysis. Bone Joint Res 2016;5:379–386. DOI: 10.1302/2046-3758.59.BJR-2016-0027.R1.
Collapse
Affiliation(s)
- M Pahuta
- University of Ottawa, The Ottawa Hospital, 501 Smyth Road, Ottawa, Ontario, Canada
| | | | | | - J Peck
- University of Ottawa, The Ottawa Hospital, 501 Smyth Road, Ottawa, Ontario, Canada
| | - P R Kim
- University of Ottawa, The Ottawa Hospital, 501 Smyth Road, Ottawa, Ontario, Canada
| | - P E Beaule
- University of Ottawa, The Ottawa Hospital, 501 Smyth Road, Ottawa, Ontario, Canada
| |
Collapse
|
30
|
Metal-on-Metal Total Hip Arthroplasty at Five to Twelve Years Follow-Up: A Concise Follow-Up of a Previous Report. J Arthroplasty 2016; 31:1773-8. [PMID: 27113940 DOI: 10.1016/j.arth.2016.01.058] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Revised: 01/12/2016] [Accepted: 01/28/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Concern has arisen regarding potential complications with modular metal-on-metal (MoM) acetabular components in total hip arthroplasty. The purpose of this study was to analyze longitudinally the longer term results of a previously reported cohort of patients utilizing a cementless modular acetabular component with a MoM bearing. METHODS One hundred sixty-nine consecutive but selected total hip arthroplasties were performed in 148 patients at 2 institutions using a modular acetabular MoM component. One hundred thirty-nine patients (158 hips) were living at minimum 5 years, 1 patient (1 hip) was lost to follow-up and 8 patients (10 hips) were deceased. Patients were evaluated clinically in terms of revision as well as radiographically. Additional testing (metal ion levels, advanced imaging) was performed when concerns for adverse local tissue reaction (ALTR) arose. RESULTS There were 6 (3.8%) additional hips revised since the prior report for a total of 7 hips (4.4%) revised at 5-12 year follow-up. All newly revised hips (3.8%) demonstrated ALTR. There were 7 (4.7%) additional cases of radiographically detected acetabular osteolysis and 7 (4.7%) cases of femoral osteolysis. CONCLUSION Longitudinal evaluation of a modular MoM bearing surface acetabular component demonstrated increased rates of ALTR and osteolysis at longer duration follow-up. Although greater than 95% of hips in this study performed well at 5-12 years, when comparing the results to metal-on-polyethylene bearings using the same acetabular component, the results were inferior. Longitudinal surveillance is warranted with this design and this bearing surface couple as cases of ALTR and osteolysis increased with longer follow-up.
Collapse
|
31
|
Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision? J Arthroplasty 2016; 31:1385-9. [PMID: 27118353 DOI: 10.1016/j.arth.2016.01.074] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 01/27/2016] [Indexed: 02/01/2023] Open
Abstract
Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided.
Collapse
|
32
|
Lainiala OS, Moilanen TPS, Hart AJ, Huhtala HSA, Sabah SA, Eskelinen AP. Higher Blood Cobalt and Chromium Levels in Patients With Unilateral Metal-on-Metal Total Hip Arthroplasties Compared to Hip Resurfacings. J Arthroplasty 2016; 31:1261-1266. [PMID: 26775067 DOI: 10.1016/j.arth.2015.11.045] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Revised: 11/12/2015] [Accepted: 11/30/2015] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Adverse soft tissue reactions in metal-on-metal (MoM) hip replacements are associated with cobalt (Co) and chromium (Cr) ions in blood. We report the prevalence and risk factors for elevated blood Co and Cr levels in patients with a unilateral MoM hip. METHODS From a single institution, blood Co and Cr levels were analyzed in 1748 patients (692 hip resurfacings and 1056 total hip arthroplasties [THAs]). Concentrations exceeding 7 ppb were considered elevated, and the risk factors for elevated levels were calculated with binary logistic regression. RESULTS Elevated blood metal ion levels were more common in MoM THA than in resurfacing patients (17.4% vs 5.9%, P < .001), and in 5 of the 7 THA brands, more than 20% of patients had elevated metal ion concentrations, whereas the proportion was less than 10% in all hip resurfacings. In resurfacings, small femoral head (odds ratio [OR] 1.30 per millimeter decrease [CI, 1.12-1.49]), high acetabular inclination (OR 1.15 per degree increase [CI 1.09-1.22]), and young age (OR 1.05 per year decrease [1.02-1.10]) were independent risk factors for elevated ions. In the THA group, female gender (OR 2.04 [CI 1.35-3.06]), longer time between surgery and ion measurement (OR 1.19 per year increase [CI 1.05-1.34]), and large headsize (OR 1.07 per millimeter increase [CI 1.01-1.13]) were risk factors for elevated ions. CONCLUSION Given the high percentage of elevated levels, the systematic surveillance of especially large diameter MoM THAs seems justified.
Collapse
Affiliation(s)
| | | | - Alister J Hart
- University College London and the Royal National Orthopaedic Hospital, London, UK
| | | | - Shiraz A Sabah
- University College London and the Royal National Orthopaedic Hospital, London, UK
| | | |
Collapse
|
33
|
Renner L, Faschingbauer M, Schmidt-Braekling T, Boettner F. Cobalt serum levels differ in well functioning Birmingham resurfacing and Birmingham modular THA. Arch Orthop Trauma Surg 2016; 136:715-21. [PMID: 26983720 DOI: 10.1007/s00402-016-2439-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Metal-on-metal (MoM) bearings are known to release metal ions secondary to wear and corrosion. This may cause local reactions (adverse soft tissue reactions and osteolysis) and systemic effects. Little is known about the exact pattern and the differences between large head MoM total hip replacements (THA) and resurfacings (HR). QUESTIONS (1) Is there a difference in metal ion concentrations between HR and MoM-THR using the same bearing design (Birmingham Hip Resurfacing System, Smith & Nephew, Inc. Memphis, TN, USA)? (2) Are metal ion levels changing over time in MoM-THA or HR? (3) Do acetabular inclination angle and femoral component size influence cobalt and chromium levels? Is there a correlation between clinical outcome and metal ion levels? MATERIALS AND METHODS A retrospective analysis was conducted in 77 well functioning unilateral Birmingham HR and 42 well functioning unilateral modular Birmingham MoM-THA (Smith & Nephew, Inc. Memphis, TN, USA) operated on between 2007 and 2012. Blood samples were taken at a minimum of 13 months and subsequent during annual follow-ups. RESULTS (1) Cobalt levels were significantly higher in MoM-THA compared to HR (p < 0.001). There was no significant difference in chromium levels (p = 0.313). (2) Cobalt is increasing over time in MoM-THA (p = 0.030) whereas metal ions remain stable in HR. (3) Metal ion levels were not affected by acetabular inclination angle and femoral component size in MoM-THA. Chromium levels correlate with the femoral component size (r = -0.240; p = 0.037), the UCLA activity score (r = -0.344; p = 0.003) and the VAS (r = 0.263; p = 0.38) in HR. CONCLUSION Considering that HR and MoM-THA used the same MoM bearing design, increased cobalt levels may be related to trunnion wear or corrosion. Elevated cobalt levels should raise concern for corrosion related failure in MoM-THA.
Collapse
Affiliation(s)
- Lisa Renner
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedic Surgery, Center for Musculoskeletal Surgery, Charite Universitaetsmedizin, Chariteplatz 1, 10117, Berlin, Germany
| | - Martin Faschingbauer
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
- Department of Orthopedics and Orthopedic Surgery, University of Ulm, Oberer Eselsberg 45, 89081, Ulm, Germany
| | - Tom Schmidt-Braekling
- Department of Orthopedic Surgery, University Hospital Muenster, Albert-Schweitzer-Campus 1, 48149, Münster, Germany
| | - Friedrich Boettner
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
34
|
Madanat R, Hussey DK, Donahue GS, Potter HG, Wallace R, Bragdon C, Muratoglu O, Malchau H. Early Lessons From a Worldwide, Multicenter, Followup Study of the Recalled Articular Surface Replacement Hip System. Clin Orthop Relat Res 2016; 474:166-74. [PMID: 26310677 PMCID: PMC4686517 DOI: 10.1007/s11999-015-4456-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2015] [Accepted: 07/07/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND Adverse local tissue reactions (ALTRs) around hip arthroplasties are an important reason for failure of metal-on-metal (MoM) hip implants. Little is known about capsular dehiscence patterns as ALTRs decompress from the hip into the surrounding tissue planes; these patterns may also influence the onset and severity of patient symptoms. QUESTIONS/PURPOSES Through a multicenter study approach, we asked: (1) Is ALTR location related to the surgical approach used for arthroplasty in patients who underwent hip arthroplasty (resurfacing or THA) with a single, recalled hip arthroplasty system? (2) Do ALTR severity and location affect patient-reported outcomes in these patients? (3) Is ALTR severity different between patients who received the resurfacing version of this component (Articular Surface Replacement [ASR]) and those who received the THA implant in this system (ASR XL)? METHODS In a multicenter prospective study of patients who had undergone surgery with use of the ASR and ASR XL hip system (DePuy Orthopaedics, Warsaw, IN, USA), 288 patients (333 hips) from two centers had a metal artifact reduction sequence MRI of the hip performed at a mean time of 6 years postsurgery. Procedures included 166 hips (50%) with ASR resurfacing and 167 hips (50%) with ASR XL THA performed between 2004 and 2010. One hundred twenty-nine hips (39%) had been operated on using a direct lateral approach and 204 using a posterior approach (61%). The EQ-5D, Harris hip score, UCLA activity score, and visual analog scale pain score were obtained for each patient. ALTRs were classified using the Anderson ALTR grading system, and the location, synovial thickness, and diameter of the ATLRs were assessed. The relationship between ALTR location and surgical approach as well as for ALTR severity and patient-reported outcomes were evaluated, and logistic regression was used to identify predictors for moderate-to-severe ALTRs. RESULTS Moderate or severe ALTRs were identified in 79 hips (24%); 41 of these hips had been operated on using the direct lateral approach and 38 using the posterior approach. In patients in whom the lateral approach was used, 83% had an anterior ALTR. Similarly, 71% of patients in the posterior approach group had posterior ALTRs. There were no differences in patient-reported outcome measures between patients with moderate-to-severe ALTRs and those with no ALTR findings on MRI (p > 0.09). Use of ASR XL was an independent risk factor for moderate-to-severe ALTRs (odds ratio, 2.8; 95% confidence interval, 1.4-5.5 p = 0.004) and patients with ASR XL also had a thicker synovium (median ASR XL = 3.6 mm [1.2-10.6 mm], median ASR = 2.6 mm [1.2-10.7 mm], p < 0.001) and larger maximal ALTR diameter (median ASR XL = 47.6 mm [14-109.70 mm], median ASR = 38.4 [17.2-118.0 mm], p = 0.02) than patients treated with ASR. CONCLUSIONS The location of ALTRs can be predicted based on the previous surgical approach to the hip. Patients with ASR XL are more likely to develop moderate-to-severe ALTRs compared with ASR patients. An extensive range of patient-reported outcome measures may not identify all patients with ALTRs further supporting the use of MRI as a screening measure for ALTRs. LEVEL OF EVIDENCE Level II, therapeutic study.
Collapse
Affiliation(s)
- Rami Madanat
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Daniel K Hussey
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Gabrielle S Donahue
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Hollis G Potter
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, NY, USA
| | | | - Charles Bragdon
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Orhun Muratoglu
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA
| | - Henrik Malchau
- Harris Orthopaedic Laboratory, Massachusetts General Hospital, 55 Fruit Street, GRJ 1231, Boston, MA, 02114, USA.
| |
Collapse
|
35
|
Do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations? Clin Orthop Relat Res 2015; 473:3903-14. [PMID: 26324830 PMCID: PMC4626498 DOI: 10.1007/s11999-015-4466-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Accepted: 07/15/2015] [Indexed: 02/08/2023]
Abstract
BACKGROUND Early adverse tissue reactions around metal-on-metal (MoM) hip replacements, especially pseudotumors, are a major concern. Because the causes and pathomechanisms of these pseudotumors remain largely unknown, clinical monitoring of patients with MoM bearings is challenging. QUESTIONS/PURPOSES The purpose of this study was to compare the lymphocyte subpopulations in peripheral blood from patients with a failed MoM hip implant with and without a pseudotumor and patients with a well-functioning MoM hip implant without a pseudotumor. Potential differences in the systemic immune response are expected to reflect local differences in the periprosthetic tissues. METHODS Consenting patients who underwent a revision of a failed MoM hip implant at The Ottawa Hospital (TOH) from 2011 to 2014, or presented with a well-functioning MoM hip implant for a postoperative clinical followup at TOH from 2012 to 2013, were recruited for this study, unless they met any of the exclusion criteria (including diagnosed conditions that can affect peripheral blood lymphocyte subpopulations). Patients with a failed implant were divided into two groups: those with a pseudotumor (two hip resurfacings and five total hip arthroplasties [THAs]) and those without a pseudotumor (10 hip resurfacings and two THAs). Patients with a well-functioning MoM hip implant (nine resurfacings and three THAs) at 5 or more years postimplantation and who did not have a pseudotumor as demonstrated sonographically served as the control group. Peripheral blood subpopulations of T cells (specifically T helper [Th] and cytotoxic T [Tc]), B cells, natural killer (NK) cells, memory T and B cells as well as type 1 (expressing interferon-γ) and type 2 (expressing interleukin-4) Th and Tc cells were analyzed by flow cytometry after immunostaining. Serum concentrations of cobalt and chromium were measured by inductively coupled plasma-mass spectrometry. RESULTS The mean percentages of total memory T cells and, specifically, memory Th and memory Tc cells were lower in patients with a failed MoM hip implant with a pseudotumor than in both patients with a failed implant without a pseudotumor and patients with a well-functioning implant without a pseudotumor (memory Th cells: 29% ± 5% [means ± SD] versus 55% ± 17%, d = 1.8, 95% confidence interval [CI] [1.2, 2.5] and versus 48% ± 14%, d = 1.6, 95% CI [1.0, 2.2], respectively; memory Tc cells: 18% ± 5% versus 45% ± 14%, d = 2.3, 95% CI [1.5, 3.1] and versus 41% ± 12%, d = 2.3, 95% CI [1.5, 3.1], respectively; p < 0.001 in all cases). The mean percentage of memory B cells was also lower in patients with a failed MoM hip implant with a pseudotumor than in patients with a well-functioning implant without a pseudotumor (12% ± 8% versus 29% ± 16%, d = 1.3, 95% CI [0.7, 1.8], p = 0.025). In addition, patients with a failed MoM hip implant with a pseudotumor had overall lower percentages of type 1 Th cells than both patients with a failed implant without a pseudotumor and patients with a well-functioning implant without a pseudotumor (5.5% [4.9%-5.8%] [median with interquartile range] versus 8.7% [6.5%-10.2%], d = 1.4, 95% CI [0.8, 2.0] and versus 9.6% [6.4%-11.1%], d = 1.6, 95% CI [1.0, 2.2], respectively; p ≤ 0.010 in both cases). Finally, serum cobalt concentrations in patients with a failed MoM hip implant with a pseudotumor were overall higher than those in patients with a well-functioning implant without a pseudotumor (5.8 µg/L [2.9-17.0 µg/L] versus 0.9 µg/L [0.6-1.3 µg/L], d = 2.2, 95% CI [1.4, 2.9], p < 0.001). CONCLUSIONS Overall, results suggest the presence of a type IV hypersensitivity reaction, with a predominance of type 1 Th cells, in patients with a failed MoM hip implant with a pseudotumor. CLINICAL RELEVANCE The lower percentages of memory T cells (specifically Th and Tc) as well as type 1 Th cells in peripheral blood of patients with a failed MoM hip implant with a pseudotumor could potentially become diagnostic biomarkers for the detection of pseudotumors. Although implant design (hip resurfacing or THA) did not seem to affect the results, as suggested by the scatter of the data with respect to this parameter, future studies with additional patients could include the analysis of implant design in addition to correlations with histological analyses of specific Th subsets in periprosthetic tissues.
Collapse
|
36
|
Walsh CP, Hubbard JC, Nessler JP, Markel DC. MRI Findings Associated with Recalled Modular Femoral Neck Rejuvenate and ABG Implants. J Arthroplasty 2015; 30:2021-6. [PMID: 26122109 DOI: 10.1016/j.arth.2015.05.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Revised: 04/20/2015] [Accepted: 05/07/2015] [Indexed: 02/08/2023] Open
Abstract
MARS-MRI is suggested for the diagnosis of adverse local tissue reactions (ALTR) in patients with recalled femoral stems with modular necks, but there has been no major study looking at MARS-MRI findings in this population. A retrospective review was performed on 312 patients who received a modular neck hip implant between October 2007 and February 2012. 62% of patients had intra-articular effusions, with 27% containing debris. Extra-capsular effusions were present in 35% of hips. 54% had synovitis and 5.4% had osteolysis. Tendinopathy and tendon disruption was present in the gluteus medius (58%/12%), hamstring (56%/12%), gluteus minimus (38%/7.7%) and iliopsoas (7.1%/4.8%). Abnormal MARS-MRI findings are associated with modular neck femoral components and can suggest underlying ALTR. MARS-MRI abnormalities merit serious consideration in this population.
Collapse
Affiliation(s)
- Christopher P Walsh
- Detroit Medical Center/Providence Hospital Orthopaedic Surgery Residency Program, Detroit, Michigan
| | - James C Hubbard
- Wayne State University School of Medicine, Detroit, Michigan
| | | | - David C Markel
- Detroit Medical Center/Providence Hospital Orthopaedic Surgery Residency Program, Detroit, Michigan; Providence Hospital and Medical Centers and The CORE Institute, Southfield, Michigan
| |
Collapse
|
37
|
Cip J, Bach C, Widemschek M, Luegmair M, Martin A. Revision of Articular Surface Replacement (ASR) Total Hip Arthroplasty: Correlation of Perioperative Data and Early Post-Revision Outcome Results. J Arthroplasty 2015; 30:1607-17. [PMID: 25956526 DOI: 10.1016/j.arth.2015.04.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Revised: 03/24/2015] [Accepted: 04/06/2015] [Indexed: 02/01/2023] Open
Abstract
The articular surface replacement (ASR) total hip arthroplasty (THA) showed accelerated failure rates due to adverse-reaction to metal debris (ARMD). Literature correlating preoperative with intraoperative revision findings respectively post-revision outcome results are rare. 30 of 99 available ASR THA were revised due to ARMD. Mean post-revision follow-up term was 2.3 years. In part, preoperative data did not correlate with intraoperative revision findings. ARMD was even found in asymptomatic patients with non-elevated ion levels. Postoperative pain and metal ions decreased significantly (P ≤ 0.016). Cobalt decreased faster than chrome. Patients with intraoperative pseudotumors, osteolysis or bilateral THA did not have higher pre- or postoperative ion values (P ≥ 0.053). Females showed higher postoperative chrome levels (P=0.031). One major post-revision complication (femoral nerve palsy) and one re-revision (late onset infection) occurred.
Collapse
Affiliation(s)
- Johannes Cip
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Christian Bach
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Mark Widemschek
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Matthias Luegmair
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| | - Arno Martin
- Department of Orthopedic Surgery, Academic Teaching Hospital Feldkirch, Medical University of Innsbruck, Feldkirch, Austria
| |
Collapse
|
38
|
Complications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty. J Funct Biomater 2015; 6:318-27. [PMID: 26020592 PMCID: PMC4493514 DOI: 10.3390/jfb6020318] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Accepted: 05/18/2015] [Indexed: 02/08/2023] Open
Abstract
Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one case and pseudo tumor formation in another case. Furthermore, we suggest a diagnostic algorithm for joint pain after MoM trapeziometacarpal joint replacement based on published experiences from MoM hip prostheses and adverse reactions to metal.
Collapse
|
39
|
Walsh CP, Hubbard JC, Nessler JP, Markel DC. Revision of Recalled Modular Neck Rejuvenate and ABG Femoral Implants. J Arthroplasty 2015; 30:822-6. [PMID: 25573180 DOI: 10.1016/j.arth.2014.12.002] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 11/19/2014] [Accepted: 12/02/2014] [Indexed: 02/01/2023] Open
Abstract
Modular neck femoral stems have been associated with adverse local tissue reactions (ALTR), leading to a voluntary recall, but these effects have not been well-characterized. A retrospective review of intraoperative findings and cobalt/chromium levels was performed in 103 hips undergoing revision for ALTR. The average preoperative serum cobalt level was 7.6 μg/L (range 1.1-23 μg/L) and chromium level was 1.8 μg/L (range 0.1-6.8 μg/L). Metallic sludge was noted in 100%, synovitis in 98%, pericapsular rind in 82%, and calcar erosion in 85%. An osteotomy was required for removal in 44%. We concluded that revision of modular neck femoral stems is associated with increased preoperative metal ion levels and stem-neck corrosion. Despite advanced stem explantation techniques, osteotomy was frequently required, leading to increased morbidity.
Collapse
Affiliation(s)
- Christopher P Walsh
- Detroit Medical Center/Providence Hospital Orthopaedic Surgery Residency Program, Detroit, Michigan
| | - James C Hubbard
- Wayne State University School of Medicine, Detroit, Michigan
| | | | - David C Markel
- Detroit Medical Center/Providence Hospital Orthopaedic Surgery Residency Program, Detroit, Michigan; Providence Hospital and Medical Centers, Southfield, Michigan
| |
Collapse
|
40
|
Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients. INTERNATIONAL ORTHOPAEDICS 2015; 39:1803-11. [PMID: 25655902 DOI: 10.1007/s00264-014-2644-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Accepted: 12/14/2014] [Indexed: 02/06/2023]
Abstract
PURPOSE Most factors considered to affect blood metal ions following metal-on-metal hip replacement are based on hip resurfacing patients. The study aims were to determine which factors affect blood metal ion concentrations following metal-on-metal total hip replacement (MoM THR). METHODS All unilateral MoM THR patients at one centre with whole-blood cobalt (Co) and chromium (Cr) concentrations measured up to May 2013 were included. Blood sampling was at a mean of 4.5 years (range 1.1-11.8 years) postoperatively. RESULTS Of 496 patients (mean age 59.1 years; 52.8% male), blood metal ions >7 μg/l were observed in 9.7% (n = 48). Large femoral head sizes (≥38 mm) had significantly higher (p < 0.0001) blood metal ions than smaller sizes (28/36 mm). Corail-Pinnacle implants produced significantly lower blood metal ions compared to other implant designs (p < 0.01 Co and Cr). Univariate linear regression demonstrated the only significant predictors of both blood Co and Cr concentrations were femoral head size (R(2) = 8.6% Co and R(2) = 3.3% Cr, both p < 0.0001) and implant design (R(2) = 8.8%, p = 0.005 Co and R(2) = 5.1%, p = 0.003 Cr). When the three THR implant design groups (Corail-Pinnacle, Synergy, Other) were analysed separately, femoral head size no longer significantly affected blood metal ions in any of the three implant design groups. CONCLUSIONS Implant design was the most important factor affecting blood metal ion concentrations. We recommend the regularity of follow-up be tailored to survival rates of various MoM THR designs rather than according to femoral head size.
Collapse
|
41
|
Pyda M, Koczy B, Widuchowski W, Widuchowska M, Stołtny T, Mielnik M, Hermanson J. Hip resurfacing arthroplasty in treatment of avascular necrosis of the femoral head. Med Sci Monit 2015; 21:304-9. [PMID: 25618763 PMCID: PMC4315641 DOI: 10.12659/msm.891031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Background Hip resurfacing is a conservative type of total hip arthroplasty but its use is controversial, especially in patients with osteonecrosis. The aim of this study was analysis of the clinical and radiographic outcomes of hip resurfacing in patients with osteonecrosis. Material/Methods Between 2007 and 2008, 30 hip resurfacing arthroplasties were performed due to osteoarthritis secondary to avascular necrosis of femoral head staged as Ficat III and IV. Patients were qualified to resurfacing arthroplasty when the extent of avascular necrosis using Kerboul’s method was <200° and the angle between avascular necrosis and head-neck junction was >20°. All patients were evaluated clinically and radiologically before and 60 months after the operation. Results The mean Harris Hip Score (HHS) score increased from 47.8 to 94.25 (p<0.05). Physical activity level (University of California, Los Angeles activity score – UCLA activity score) improved from 3.7 to 7.55 (p<0.05). No implant migration was observed. Conclusions Management of osteonecrosis of the hip with resurfacing arthroplasty seems to be effective in strictly-selected patients.
Collapse
Affiliation(s)
- Michał Pyda
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| | - Bogdan Koczy
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| | - Wojciech Widuchowski
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| | - Małgorzata Widuchowska
- Department of Internal Medicine and Rheumatology, Medical University of Silesia, Katowice, Poland
| | - Tomasz Stołtny
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| | - Michał Mielnik
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| | - Jacek Hermanson
- Department of Trauma and Orthopaedics, District Trauma and Orthopaedic Hospital, Piekary Śląskie, Poland
| |
Collapse
|
42
|
Cemented metal-on-metal total hip replacement with 28-mm head: prospective, long-term, clinical, radiological and metal ions data. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2014; 25:749-55. [DOI: 10.1007/s00590-014-1578-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2014] [Accepted: 12/08/2014] [Indexed: 11/26/2022]
|
43
|
Campbell PA, Kung MS, Hsu AR, Jacobs JJ. Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions? Clin Orthop Relat Res 2014; 472:3718-27. [PMID: 25160942 PMCID: PMC4397772 DOI: 10.1007/s11999-014-3893-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Metal-on-metal (MoM) total hip arthroplasties (THAs) and the head-neck and neck-body junctions in modular THA are associated with a variety of local and systemic reactions to their related wear and corrosion products. Although laboratory testing is available, the relationship between laboratory values--including serum metal ion levels--and adverse local tissue reactions (ALTRs) remains controversial and incompletely characterized. QUESTIONS/PURPOSES (1) What is the range of serum metal levels associated with ALTR in patients who have MoM THAs or corrosion at the head-neck and neck-body junctions in metal-on-polyethylene (or ceramic-on-polyethylene) THAs? (2) How much wear occurs in patients with MoM total hips? (3) Is there evidence of a dose-response relationship between wear and ALTR? METHODS PubMed and Embase databases were reviewed for English-language studies assessing serum metal levels in the presence of ALTR and papers describing the results of wear measurements from revised MoM implants and ALTR histopathology were systematically reviewed. Reported linear wear data were separated into groups with ALTR and without ALTR as listed in individual papers and graphed to determine whether a dose-response relationship was present between wear and ALTR. Overall, 15 studies including 338 hips with ALTR with corresponding serum metal levels were identified and analyzed. Twelve studies reported the wear depth or volume of MoM components from patients with a variety of local reactions. Two studies investigated corrosion at the head-neck and neck-body junctions in metal-on-polyethylene THA. There was a high level of variability and study heterogeneity, and so data pooling (meta-analysis) could not be performed. RESULTS Average reported metal concentrations were elevated above established normal values in patients with ALTR (cobalt concentrations ranged from 5 to 40 ppb, and chromium levels ranged from 5 to 54 ppb). Whereas several studies demonstrated that patients with ALTR had higher average linear wear of the bearing surfaces, this finding was not made in all studies that we identified in this systematic review. Because of this high degree of variability, no clear dose-response relationship between wear and ALTR could be established. CONCLUSIONS Serum metal level analysis and implant retrieval analysis both contribute to the understanding of ALTR. Serum metal levels generally are elevated in the presence of ALTR but should not be used in isolation for clinical decision-making. Many but not all patients with ALTR, including those with pseudotumors, demonstrate high wear, but more data and more systematic descriptions of the histopathology are needed to define the amount of wear that induces adverse reactions.
Collapse
Affiliation(s)
- Patricia A. Campbell
- Orthopaedic Institute for Children, Los Angeles/UCLA Department of Orthopaedic Surgery, Los Angeles, CA USA ,J Vernon Luck Research Center, UCLA/Orthopaedic Hospital, 403 W Adams Boulevard, Los Angeles, CA 90007 USA
| | - Michael S. Kung
- Orthopaedic Institute for Children, Los Angeles/UCLA Department of Orthopaedic Surgery, Los Angeles, CA USA
| | | | | |
Collapse
|
44
|
Implication of femoral stem on performance of articular surface replacement (ASR) XL total hip arthroplasty. J Arthroplasty 2014; 29:2127-35. [PMID: 25108735 DOI: 10.1016/j.arth.2014.06.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2014] [Revised: 06/14/2014] [Accepted: 06/29/2014] [Indexed: 02/01/2023] Open
Abstract
Taper junctions of large diameter metal-on-metal femoral heads and femoral stems were described as metal ion generator due to accelerated wear and corrosion. However, literature about the Articular Surface Replacement (ASR) total hip arthroplasty (THA) invariably deals with stems manufactured by DePuy Orthopedics (Warsaw, IN, USA). Nothing is known whether different stems with common 12/14 mm tapers affect failure rate or ion release. 99 ASR THA (88 patients) implanted with CoxaFit or ARGE Geradschaft stems (K-Implant, Hannover, Germany) were retrospectively analyzed. After a mean follow-up of 3.5 years revision rate was 24.5%, mostly due to adverse reaction to metal debris (ARMD). CT scan revealed component loosening in 10.3% and pseudotumoral lesions in 12.6%. Elevated ion concentrations (>7 μg/l) were found in 38.6%.
Collapse
|
45
|
Fox CM, Bergin KM, Kelly GE, McCoy GF, Ryan AG, Quinlan JF. MRI findings following metal on metal hip arthroplasty and their relationship with metal ion levels and acetabular inclination angles. J Arthroplasty 2014; 29:1647-52. [PMID: 24793890 DOI: 10.1016/j.arth.2014.03.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Revised: 03/16/2014] [Accepted: 03/25/2014] [Indexed: 02/01/2023] Open
Abstract
Following the global recall of all ASR metal on metal hip products, our aim was to correlate MRI findings with acetabular inclination angles and metal ion levels in patients with these implants. Both cobalt and chromium levels were significantly higher in the presence of a periprosthetic fluid collection. There was no association between the presence of a periprosthetic mass, bone marrow oedema, trochanteric bursitis or greater levels of abductor muscle destruction for cobalt or chromium. There was no association between the level of periprosthetic tissue reaction and the acetabular inclination angle with any of the pathologies identified on MRI. The relationship between MRI pathology, metal ion levels and acetabular inclination angles in patients with ASR implants remains unclear adding to the complexity of managing patients.
Collapse
Affiliation(s)
- Ciara M Fox
- Lourdes Orthopaedic Hospital, Kilcreene, Kilkenny, Ireland
| | - Karen M Bergin
- Lourdes Orthopaedic Hospital, Kilcreene, Kilkenny, Ireland
| | - Gabrielle E Kelly
- School of Mathematical Sciences, University College Dublin, Belfield, Dublin 4, Ireland
| | - Gerry F McCoy
- Lourdes Orthopaedic Hospital, Kilcreene, Kilkenny, Ireland
| | - Anthony G Ryan
- Department of Radiology, Waterford Regional Hospital, Waterford, Ireland
| | - John F Quinlan
- Lourdes Orthopaedic Hospital, Kilcreene, Kilkenny, Ireland
| |
Collapse
|
46
|
Millstine DM, Hakes HJ, Mayer AP, Spangehl MJ. Heavy metal? Recognizing complications of metal on metal hip arthroplasty. J Womens Health (Larchmt) 2014; 23:777-9. [PMID: 24932678 DOI: 10.1089/jwh.2014.4868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Denise M Millstine
- 1 Division of Women's Health-Internal Medicine, Mayo Clinic Arizona , Scottsdale, Arizona
| | | | | | | |
Collapse
|
47
|
Reduction of Metal Artifacts From Alloy Hip Prostheses in Computer Tomography. J Comput Assist Tomogr 2014; 38:828-33. [DOI: 10.1097/rct.0000000000000125] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
48
|
Kitagawa A, Chin T, Tsumura N, Iguchi T. Metal sensitivity in patients before and after total knee arthroplasty (TKA): comparison between ceramic surfaced oxidized zirconium and cobalt-chromium implants. ACTA ACUST UNITED AC 2013. [DOI: 10.7243/2052-594x-1-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|