1
|
Wongpakdee T, Crenshaw K, Figueroa Wong HM, de Oliveira MF, Nacapricha D, McCord BR. The development of screen-printed electrodes modified with gold and copper nanostructures for analysis of gunshot residue and low explosives. Forensic Sci Int 2024; 364:112243. [PMID: 39378650 DOI: 10.1016/j.forsciint.2024.112243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/22/2024] [Accepted: 10/03/2024] [Indexed: 10/10/2024]
Abstract
Due to their portability, sensitivity, and ease of use, electrochemical sensors have recently become a popular method for rapid, on-site analysis. This study presents a proof of principle for the application of modified screen-printed carbon electrodes (SPCEs) for the detection of signature metals (Pb, Sb, and Zn) commonly found in gunshot residue (GSR), as well as for the detection of nitrate/nitrite in organic GSR and low explosives. To achieve these two aims, we have examined various electrode surface modifications. For metal detection, SPCEs were modified by electrodeposition of gold to improve sensitivity. GSR samples taken from two types of cartridge cases and shooting-related surfaces were analyzed using the Au-modified SPCEs. For nitrate/nitrite analysis, further electrode surface modifications were carried out by depositing Cu(II) onto the Au-SPCEs to enhance signal through catalytic activity of the copper surfaces. Both unburned and burned forms of black powder samples, as well as burned smokeless powder, were then analyzed using the Cu/Au-SPCEs. In conclusion, due to their low cost and portability, these sensors should prove useful for rapid forensic examination.
Collapse
Affiliation(s)
- Thinnapong Wongpakdee
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand; Florida International University, Modesto Maidique Campus, Department of Chemistry and Biochemistry, 11200 SW 8th St., Miami, FL 33199, USA
| | - Karin Crenshaw
- Firearm and Tool Mark Unit, Crime Laboratory, Sheriff's Office, Broward County, Fort Lauderdale, FL 33301, USA
| | - Hery M Figueroa Wong
- Firearm and Tool Mark Unit, Crime Laboratory, Sheriff's Office, Broward County, Fort Lauderdale, FL 33301, USA
| | - Marcelo Firmino de Oliveira
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto-Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Bruce R McCord
- Florida International University, Modesto Maidique Campus, Department of Chemistry and Biochemistry, 11200 SW 8th St., Miami, FL 33199, USA.
| |
Collapse
|
2
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
3
|
Fotouhi M, Seidi S, Razeghi Y, Torfinezhad S. A dual-mode assay kit using a portable potentiostat connected to a smartphone via Bluetooth communication and a potential-power angle-based paper device susceptible for low-cost point-of-care testing of iodide and dopamine. Anal Chim Acta 2024; 1287:342127. [PMID: 38182351 DOI: 10.1016/j.aca.2023.342127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 12/04/2023] [Accepted: 12/08/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Considering that the brain controls most of the body's activities, it is very important to measure the factors affecting its function, such as dopamine and iodide. Due to the growing population in the world, it is necessary to provide fast, cheap and accurate methods with the capability of on-site analysis and without the need for invasive sampling and operator skill. As a result, there is a strong desire to replace laboratory instruments with small sensors for point-of-care testing. Paper-based analytical devices (PADs) are one of the popular zero-cost approaches to achieve this goal. RESULTS We developed a simple and disposable diagnostic paper system based on electroanalytical and potential-power angle-based methods. First, we prepared an angle-based analytical system capable of performing semi-quantitative iodide analysis simply by reading the colored angle traveled. This system design is based on a channel containing complex reagents and two pencil-drawn electrodes to apply a constant voltage accelerating the anions migration. Meanwhile, a three-electrode system based on conductive pencil graphite is developed to measure dopamine concentration based on linear sweep voltammetry. For the quantitative analysis, the voltammetric data was wirelessly transmitted to a mobile device via Bluetooth communication. In this context, a power supply providing the required voltage for the migration of iodide ions, a portable potentiostat system, and a mobile application for measuring dopamine were developed. The calibration curves for I- and dopamine range from 3.5 × 10-4-47.0 × 10-4 and 10.0 × 10-6-1000.0 × 10-6 mol L-1 with LODs of 2.3 × 10-4 and 5.0 × 10-6 mol L-1, respectively. SIGNIFICANCE AND NOVELTY A new portable dual-mode voltage-assisted integrated PAD platform was designed for iodide and dopamine analysis. The characteristics of this device allow non-experts to carry out in-field analysis using sub-100 μL saliva sample with a time-to-result of <10 min along with reducing the overall cost and operational complexity.
Collapse
Affiliation(s)
- Mina Fotouhi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran.
| | - Yasaman Razeghi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran; Nanomaterial, Separation and Trace Analysis Research Lab, K.N. Toosi University of Technology, P.O. Box 16315-1618, Postal Code 15418-49611, Tehran, Iran
| | - Shahab Torfinezhad
- Faculty of Electrical Engineering, K.N. Toosi University of Technology, Tehran, Iran
| |
Collapse
|
4
|
Guo Y, Zhang X, Zhang H, Liu Y, Shi J, Meng H, Chen X, Lan Q, Zhu B. Application of microfluidic technologies in forensic analysis. Electrophoresis 2023; 44:1725-1743. [PMID: 37857551 DOI: 10.1002/elps.202200268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 08/17/2023] [Accepted: 08/28/2023] [Indexed: 10/21/2023]
Abstract
The application of microfluidic technology in forensic medicine has steadily expanded over the last two decades due to the favorable features of low cost, rapidity, high throughput, user-friendliness, contamination-free, and minimum sample and reagent consumption. In this context, bibliometric methods were adopted to visualize the literature information contained in the Science Citation Index Expanded from 1989 to 2022, focusing on the co-occurrence analysis of forensic and microfluidic topics. A deep interpretation of the literature was conducted based on co-occurrence results, in which microfluidic technologies and their applications in forensic medicine, particularly forensic genetics, were elaborated. The purpose of this review is to provide an impartial evaluation of the utilization of microfluidic technology in forensic medicine. Additionally, the challenges and future trends of implementing microfluidic technology in forensic genetics are also addressed.
Collapse
Affiliation(s)
- Yuxin Guo
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Xingru Zhang
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- College of Forensic Medicine, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, P. R. China
| | - Haoqing Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Yaoshun Liu
- Ankang Hospital of Traditional Chinese Medicine, Ankang, Shaanxi, P. R. China
| | - Jianfeng Shi
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Haotian Meng
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Xin Chen
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Qiong Lan
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- Microbiome Medicine Center, Department of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, P. R. China
| | - Bofeng Zhu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- Microbiome Medicine Center, Department of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, P. R. China
| |
Collapse
|
5
|
Enhancing of detection resolution via designing of a multi-functional 3D connector between sampling and detection zones in distance-based microfluidic paper-based analytical device: multi-channel design for multiplex analysis. Mikrochim Acta 2022; 189:482. [DOI: 10.1007/s00604-022-05585-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 11/17/2022] [Indexed: 12/03/2022]
|
6
|
Wongpakdee T, Buking S, Ratanawimarnwong N, Saetear P, Uraisin K, Wilairat P, Tiyapongpattana W, Nacapricha D. Simple gunshot residue analyses for estimating firing distance: Investigation with four types of fabrics. Forensic Sci Int 2021; 329:111084. [PMID: 34752997 DOI: 10.1016/j.forsciint.2021.111084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Revised: 10/23/2021] [Accepted: 10/25/2021] [Indexed: 10/20/2022]
Abstract
This work presents two simple methods for estimating the firing distance from the gunshot residues (GSRs) on fabric targets. Four types of fabric targets, namely twill weave denim cotton-polyester (80/20), jersey knitting 100% cotton, plain weave cotton-polyester (80/20) and plain weave cotton-polyester (60/40), were employed. The firing tests were carried out using these white fabrics as targets at distances of 5-100 cm, respectively. In the first method, digital images of the black GSRs on fabric materials were recorded inside an illuminated box and the inverted gray intensity values were plotted against the firing distances. Since the plots of all fabrics are not significantly different, the estimation of firing distance employs the same exponential curve for all test fabrics. Although simple, the imaging method is not suitable for dark-colored materials. A chemical-based method was therefore developed as an alternative method. In the second method, a small disposable microfluidic paper-based analytical device (μPAD) was employed for detecting Pb(II) extracted from the GSRs. The μPAD method uses the measurement of the length of a narrow band of a pink color resulting from reaction between rhodizonate reagent and the Pb(II) extract. The plots indicated that the data of thick denim material are significantly different to other test fabrics which are much thinner. These three fabrics share the same estimation curve. However, it is recommended that the separate estimation curve for denim materials must be used. Both methods are suitable for short range firing distance, no further than 60 cm, since at greater distances the inverted gray intensity and the 'band-length' methods are unable to detect the GSRs.
Collapse
Affiliation(s)
- Thinnapong Wongpakdee
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Supatana Buking
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Office of Police Forensic Science, Bangkok 10330, Thailand
| | - Nuanlaor Ratanawimarnwong
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumvit 23, Bangkok 10110, Thailand
| | - Phoonthawee Saetear
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Kanchana Uraisin
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Prapin Wilairat
- Analytical Sciences and National Doping Test Institute, Mahidol University, Rama VI Rd., Bangkok 10400, Thailand
| | - Warawut Tiyapongpattana
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry, Faculty of Science and Technology, Thammasat University, Pathumthani 12121, Thailand.
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (Firstlabs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand.
| |
Collapse
|
7
|
Musile G, Agard Y, Wang L, De Palo EF, McCord B, Tagliaro F. Paper-based microfluidic devices: On-site tools for crime scene investigation. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116406] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
8
|
Karamahito P, Sitanurak J, Nacapricha D, Wilairat P, Chaisiwamongkhol K, Phonchai A. Paper device for distance-based visual quantification of sibutramine adulteration in slimming products. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105784] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
9
|
Trends in Gunshot Residue Detection by Electrochemical Methods for Forensic Purpose. JOURNAL OF ANALYSIS AND TESTING 2021. [DOI: 10.1007/s41664-020-00152-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
10
|
|
11
|
Buking S, Suedomi Y, Nacapricha D, Kaneta T. Characterization of Pieces of Paper That Form Reagent Containers for Use as Portable Analytical Devices. ACS OMEGA 2019; 4:15249-15254. [PMID: 31552371 PMCID: PMC6751694 DOI: 10.1021/acsomega.9b02226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Accepted: 08/21/2019] [Indexed: 06/10/2023]
Abstract
Reagent-deposited pieces of paper were characterized by the use of a compact conductometer, a compact pH sensor, and a conventional spectrophotometer to assess their suitability for use as reagent containers. The pieces of paper were fabricated by wax printing to form a limited hydrophilic area to which a consistent volume of an aqueous reagent could be added. The pieces of paper without the reagent increased the conductivity of water gradually because of the release of sodium salts, whereas pH of NaOH decreased because of the acidity of the functional groups in the paper. Three reagents, sulfamic acid as an acid, Na2CO3 as a base, and BaCl2 as a metal salt, were deposited on the pieces of paper to evaluate their ability to release from the pieces of paper. Sulfamic acid and Na2CO3 were released in quantities of 58 and 73% into water after 420 s, whereas 100% of BaCl2 was released after 480 s. The conductometric titrations of NaOH, HCl, and Na2SO4, and the spectrophotometry of Fe2+ were examined using the pieces of paper that contained sulfamic acid, Na2CO3, BaCl2, and 1,10-phenanthroline. Titrations using the pieces of paper suggested that the reagents were quantitatively released into the titrant, which resulted in a linear relationship between the endpoints and the equivalent points. In 120 s of soaking time, 60-70% of the reagents were released. The spectrophotometric measurements of Fe2+ indicated that when an excess amount of the reagents was deposited onto the pieces of paper, they nonetheless sufficiently fulfilled the role of a reagent container.
Collapse
Affiliation(s)
- Supatana Buking
- Flow
Innovation-Research for Science and Technology Laboratories
(FIRST Labs) and Department of Chemistry and Center of Excellence for Innovation in
Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Yusuke Suedomi
- Department
of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan
| | - Duangjai Nacapricha
- Flow
Innovation-Research for Science and Technology Laboratories
(FIRST Labs) and Department of Chemistry and Center of Excellence for Innovation in
Chemistry, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
| | - Takashi Kaneta
- Department
of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama 700-8530, Japan
| |
Collapse
|
12
|
Boonpoempoon T, Wonsawat W, Kaneta T. Long-term stabilization of hydrogen peroxide by poly(vinyl alcohol) on paper-based analytical devices. Sci Rep 2019; 9:12951. [PMID: 31506489 PMCID: PMC6736875 DOI: 10.1038/s41598-019-49393-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 08/23/2019] [Indexed: 11/29/2022] Open
Abstract
Stabilizing reagents that can be deposited onto paper is an important issue for researchers who depend on paper-based analytical devices (PADs), because long-term stability of the devices is essential in point-of-care testing. Here, we found that poly(vinyl alcohol) (PVA) would stabilize hydrogen peroxide placed on a paper substrate following exposure to air. Horseradish peroxidase was employed as a sample in colorimetric measurements of PADs after hydrogen peroxide and 3,3',5,5'-tetramethylbenzidine were deposited as substrates in an enzymatic reaction. The addition of PVA to hydrogen peroxide significantly suppressed its degradation. Concentrations of PVA that ranged from 0.5 to 2%, increased the duration of the stability of hydrogen peroxide, and the results for a PVA concentration of 1% approximated those of 2% PVA. Storage of the PADs at 4 °C in a refrigerator extended the stability of the hydrogen peroxide containing 2% PVA by as much as 30 days. The stability of hydrogen peroxide without PVA was degraded after one day under room temperature.
Collapse
Affiliation(s)
- Tuchpongpuch Boonpoempoon
- Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok, Thailand
| | - Wanida Wonsawat
- Department of Chemistry, Faculty of Science and Technology, Suan Sunandha Rajabhat University, Bangkok, Thailand
| | - Takashi Kaneta
- Department of Chemistry, Graduate School of Natural Science and Technology, Okayama University, Okayama, Japan.
| |
Collapse
|
13
|
Mistek E, Fikiet MA, Khandasammy SR, Lednev IK. Toward Locard's Exchange Principle: Recent Developments in Forensic Trace Evidence Analysis. Anal Chem 2018; 91:637-654. [PMID: 30404441 DOI: 10.1021/acs.analchem.8b04704] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Ewelina Mistek
- Department of Chemistry , University at Albany, SUNY , 1400 Washington Avenue , Albany , New York 12222 , United States
| | - Marisia A Fikiet
- Department of Chemistry , University at Albany, SUNY , 1400 Washington Avenue , Albany , New York 12222 , United States
| | - Shelby R Khandasammy
- Department of Chemistry , University at Albany, SUNY , 1400 Washington Avenue , Albany , New York 12222 , United States
| | - Igor K Lednev
- Department of Chemistry , University at Albany, SUNY , 1400 Washington Avenue , Albany , New York 12222 , United States
| |
Collapse
|