1
|
Konopińska J, Gołaszewska K, Saeed E. Long-term efficacy and safety of ab externo canaloplasty in the Polish Caucasian population with open-angle glaucoma: A 3-year retrospective study. PLoS One 2024; 19:e0312236. [PMID: 39413111 PMCID: PMC11482709 DOI: 10.1371/journal.pone.0312236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Accepted: 10/03/2024] [Indexed: 10/18/2024] Open
Abstract
This study aimed to assess the effectiveness and safety of ab externo canaloplasty over a 3-year follow-up period in Polish Caucasian patients with glaucoma. This retrospective study of a cases series was conducted at the Department of Ophthalmology Medical University of Bialystok, Poland. Primary outcome measures were intraocular pressure and medication burden. Secondary outcome measures were best corrected visual acuity, retinal nerve fiber layer thickness, visual field test results, endothelial cell density, intraoperative and postoperative complications, and additional glaucoma surgery. The study group consisted of 160 eyes diagnosed with early to-moderate primary open-angle glaucoma and treated with ab externo canaloplasty from 2014 to 2020. The criteria for qualified and complete success were intraocular pressure < 18 mmHg or ≥ 20% reduction in intraocular pressure from baseline with or without antiglaucoma medications, respectively. After surgery, the mean intraocular pressure decreased from 19.23 ± 4.33 to 14.52 ± 3.79 mmHg, which constituted a 36.7 ± 7.8% reduction compared to the baseline value. The number of medications decreased by two at the end of the study period (from 2.69 ± 1.05 to 0.32 ± 0.75). Complete and qualified success were achieved in 58.7% and 68.7% of the patients, respectively, at the end of follow-up. An incomplete cannulation of Schlemm's canal was the most common intraoperative complication, occurring in 32 eyes (20%). The most frequent postoperative complications were hyphema, Descemet's membrane detachment, and a transient increase in intraocular pressure. Additional surgical procedure was required in seven cases (4.4%). In 16 patients (10%), medical treatment was re-administered. Overall, our findings suggest that ab externo canaloplasty is a good option for Polish Caucasian patients with primary open-angle glaucoma. It reduces intraocular pressure and has a low postoperative complication rate. Additional glaucoma surgery or re-administration of medications is required if the target intraocular pressure is unsatisfactory.
Collapse
Affiliation(s)
- Joanna Konopińska
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| | - Kinga Gołaszewska
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| | - Emil Saeed
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| |
Collapse
|
2
|
Cantor L, Lindfield D, Ghinelli F, Świder AW, Torelli F, Steeds C, Dickerson Jr JE, Nguyen DQ. Systematic Literature Review of Clinical, Economic, and Humanistic Outcomes Following Minimally Invasive Glaucoma Surgery or Selective Laser Trabeculoplasty for the Treatment of Open-Angle Glaucoma with or Without Cataract Extraction. Clin Ophthalmol 2023; 17:85-101. [PMID: 36636619 PMCID: PMC9831079 DOI: 10.2147/opth.s389406] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/23/2022] [Indexed: 01/07/2023] Open
Abstract
Introduction Selective laser trabeculoplasty (SLT) and minimally invasive glaucoma surgery (MIGS) are increasingly used options for mild-to-moderate open-angle glaucoma (OAG) care. While most MIGS devices are indicated for use in combination with cataract surgery only, with phacoemulsification playing a role in lowering IOP, newer technologies can also be used as standalone glaucoma surgery. Methods This systematic literature review (SLR) aimed to assess the clinical, economic, and humanistic outcomes of MIGS and SLT for the treatment of OAG and was conducted according to PRISMA guidelines. Studies that assessed MIGS or SLT in at least one treatment arm versus any other glaucoma treatment in adults with mild-to-moderate OAG were included. Clinical, humanistic (health-related quality of life [HRQoL] and patient burden), and economic data were extracted, and the methodological quality of included studies was evaluated. Results A total of 2720 articles were screened, and 81 publications were included. Fifty-eight reported clinical outcomes. The majority assessed iStent or iStent inject (n=41), followed by OMNI (n=9), gonioscopy-assisted transluminal trabeculotomy (GATT) or the Kahook Dual Blade (KDB) (n=7), Hydrus (n=6), SLT (n=5), Xen Gel Stent (n=2), PreserFlo (n=1), and iTrack (n=1). IOP reduction was observed across prospective studies, varying from -31% to -13.7% at month 6 and from -39% to -11.4% at year 1 versus baseline. Most adverse events were transient and non-serious. Limited humanistic and economic data were identified. Conclusion Given their established efficacy and safety, there is a rationale for wider use of MIGS in mild-to-moderate OAG. Of the MIGS devices, iStent and OMNI have the largest clinical evidence base supporting their sustained effectiveness.
Collapse
Affiliation(s)
- Louis Cantor
- Eugene and Marilyn Glick Eye Institute, Indiana School of Medicine, Indianapolis, IN, USA
| | - Dan Lindfield
- Royal Surrey County Hospital, Guildford, England, UK
| | | | | | - Francesca Torelli
- Valid Insight, Macclesfield, England, UK,Correspondence: Francesca Torelli, Valid Insight, Ropewalks, Newton St, Macclesfield, SK11 6QJ, UK, Tel +44 203 750 9833 Ext 703, Email
| | | | - Jaime E Dickerson Jr
- Sight Sciences, Menlo Park, CA, USA,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| | - Dan Q Nguyen
- Mid-Cheshire Hospitals NHS Foundation Trust, Crewe, UK
| |
Collapse
|
3
|
Gallardo MJ, Dhamdhere K, Dickerson JE. Canaloplasty and Trabeculotomy Ab Interno Combined with Cataract Surgery: 12-Month Outcomes in Hispanic Patients with Open-Angle Glaucoma. Clin Ophthalmol 2022; 16:905-908. [PMID: 35356700 PMCID: PMC8959719 DOI: 10.2147/opth.s358878] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 03/15/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
| | - Kavita Dhamdhere
- Sight Sciences Inc., Menlo Park, CA, USA.,Mahatma Gandhi Medical College and Research Center, Wardha, India
| | - Jaime E Dickerson
- Sight Sciences Inc., Menlo Park, CA, USA.,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| |
Collapse
|
4
|
Jabłońska J, Lewczuk K, Konopińska J, Mariak Z, Rękas M. Microinvasive glaucoma surgery: a review and classification of implant-dependent procedures and techniques. Acta Ophthalmol 2022; 100:e327-e338. [PMID: 33988310 PMCID: PMC9291507 DOI: 10.1111/aos.14906] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/08/2021] [Accepted: 04/22/2021] [Indexed: 12/25/2022]
Abstract
The aim of this article is to discuss how physiology and anatomical background affect the effectiveness of implant‐dependent microinvasive glaucoma surgery (MIGS). First, we provide a micro view of aqueous outflow and tissue behaviour. Second, we review studies exploring the mechanisms of the pressure‐lowering effect of MIGS, as well as tissue behaviour during aqueous flow and tissue motion. We also describe and classify microinvasive surgical procedures and the most important types of implants, as well as their mechanisms of action, implantation techniques and efficacy. Further, we summarize the indications and surgical results presented in recent studies, providing an evidence‐based update on novel and emerging MIGS techniques for the treatment of open‐angle glaucoma. These data can help surgeons to personalize the management of glaucoma and to choose the best MIGS option for individual glaucoma patients.
Collapse
Affiliation(s)
- Joanna Jabłońska
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Katarzyna Lewczuk
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Joanna Konopińska
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Zofia Mariak
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Marek Rękas
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| |
Collapse
|
5
|
Su WW. Trabecular microbypass stent combined with phacoemulsification in patients with open-angle glaucoma, 1-year outcome in a Taiwanese population. Taiwan J Ophthalmol 2022. [DOI: 10.4103/2211-5056.364567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
|
6
|
Evaluation of the Efficacy and Safety of Canaloplasty and iStent Bypass Implantation in Patients with Open-Angle Glaucoma: A Review of the Literature. J Clin Med 2021; 10:jcm10214881. [PMID: 34768400 PMCID: PMC8584607 DOI: 10.3390/jcm10214881] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 12/28/2022] Open
Abstract
The aim of the paper was to evaluate the efficacy and safety of minimally invasive antiglaucoma procedures: Canaloplasty and iStent bypass implantation with and without phacoemulsification in patients with primary open-angle glaucoma (POAG). A systematic review of the recent literature was performed based on the PubMed, Google Scholar, Web of Science and Scopus databases. The effectiveness of the procedures was evaluated based on the reduction of intraocular pressure (IOP) and the amount of antiglaucoma medication used before and after surgery. Safety of the treatments was evaluated based on the number of incidences of certain intraoperative and postoperative complications. Independent prospective randomized controlled trials (PRCTs) have demonstrated that both procedures, canaloplasty and iStent implantation, are effective in reducing IOP and the amount of antiglaucoma medication. Considering the safety profile of these procedures, both canaloplasty and iStent implantation are associated with low rates of postoperative complications and have similar safety profiles. Further studies are needed to confirm the results of our analysis, including a high-quality randomized controlled trial comparing canaloplasty and iStent bypass implantation
Collapse
|
7
|
Ansari E. 5-year outcomes of single iStent (G1) trabecular microbypass implantation with phacoemulsification in moderately advanced primary open angle glaucoma. PLoS One 2021; 16:e0257015. [PMID: 34529692 PMCID: PMC8445476 DOI: 10.1371/journal.pone.0257015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 08/23/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose To evaluate the safety and efficacy of combined phacoemulsification and single iStent (G1) (iStent, Glaukos Corp. San Clemente, USA), implantation in moderately advanced primary open angle glaucoma (POAG) with 5-years follow-up. Methods Retrospective, interventional case series. All subjects had POAG and underwent single iStent implantation+ phaco+IOL by a single surgeon, with 5 years follow-up. Primary outcome measures: reduction in intraocular pressure (IOP) and proportion of eyes achieving at least 20% reduction of IOP at 5 years. Secondary outcome measures: number of glaucoma drops at 1 through to 5 years; change in visual field mean deviation (MD) at year 5 compared to baseline. Results 35 eyes of 26 patients were included. Mean (sd) medicated pre-op IOP was 18.5 (3.2) mm Hg on mean (sd) 2.3 (1.0) medications. Mean IOP was reduced to 15.9 (4.5) mm Hg on 2.2 (0.9) drops, 15.0mm (4.5) mm Hg on 2.3 (0.9) drops, 15.6 (3.6) mm Hg on 2.5 (1.0) drops, 15.7 (4.43) mmHg on 2.6 (1.0) drops and 14.7 (3.02) mmHg (P<0.001) on 2.7 (1.14) drops (P = 0.06) from 1 through to 5 years. At year 5, 62% of eyes had achieved at least 20% reduction in IOP. MD reduced from -8 (8.1) dB to -10.7 (13.4) dB over 5 years (p = 0.8) at 0.54dB/ annum. One eye required filtering surgery. There were no sight-threatening complications. Conclusion This study showed sustained IOP reduction and excellent safety profile for single iStent implantation. Uniquely it provides data for a more severe stage of glaucoma, and also visual field data, which indicated no significant change through 5 years.
Collapse
Affiliation(s)
- Ejaz Ansari
- Maidstone & Tunbridge Wells NHS Trust, Maidstone, Kent, United Kingdom
- Canterbury Christ Church University, Canterbury, United Kingdom
- * E-mail:
| |
Collapse
|
8
|
Three-Year Outcomes of Second-generation Trabecular Micro-bypass Stents (iStent inject) With Phacoemulsification in Various Glaucoma Subtypes and Severities. J Glaucoma 2021; 30:266-275. [PMID: 33105306 DOI: 10.1097/ijg.0000000000001716] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Accepted: 10/04/2020] [Indexed: 12/21/2022]
Abstract
PRECIS This longitudinal case series provides valuable long-term data on the safety and efficacy of iStent inject with concomitant cataract surgery. Patients experienced significant and durable reductions in both intraocular pressure (IOP) and medication burden through 3 years postoperative. PURPOSE The purpose of this study was to examine the 3-year effectiveness and safety of iStent inject second-generation trabecular micro-bypass stent implantation with concomitant phacoemulsification cataract surgery in eyes with various glaucoma subtypes and severities. METHODS This was a single-center consecutive case series. Three-year outcomes included mean IOP and medications, the proportions of eyes with IOP ≤18, ≤15, and ≤12 mm Hg, and success (absence of secondary glaucoma interventions). Safety included best-corrected visual acuity (BCVA), cup-to-disc ratio, visual field (VF) mean deviation, retinal nerve fiber layer (RNFL), and ganglion cell-inner plexiform layer (GCIPL) thickness, and adverse events. RESULTS A total of 124 eyes with different glaucoma subtypes and severities were included. At 3 years postoperative, mean IOP reduced from 16.90±3.85 mm Hg preoperatively to 13.17±2.83 mm Hg (22% reduction, P<0.001) and mean medication burden decreased from 2.38±1.29 medications preoperatively to 1.16±1.22 medications (51% reduction, P<0.001). At 3 years, 96% of eyes achieved IOP ≤18 mm Hg (vs. 69% preoperatively), 80% of eyes achieved IOP ≤15 mm Hg (vs. 40% preoperatively), and 42% of eyes achieved IOP ≤12 mm Hg (vs. 7% preoperatively) with 76% of eyes eliminating ≥1 medication and 37% of eyes eliminating ≥2 medications versus preoperative medication burden. The 3-year cumulative survival rate was 74%. Postphacoemulsification BCVA improvement was preserved, and cup-to-disc ratio, VF mean deviation, and RNFL and GCIPL thickness remained stable. A favorable safety profile included no intraoperative complications and few, transient, postoperative adverse events. CONCLUSION Significant and sustained IOP and medication reductions were achieved through 3 years after iStent inject implantation with cataract surgery in a real-world clinical population with mild-to-severe glaucoma, along with favorable safety including stable BCVA, VF, and RNFL and GCIPL thickness.
Collapse
|
9
|
Trabecular Microbypass Stent and Phacoemulsification in African American Patients With Open-angle Glaucoma: Outcomes and Effect of Prior Laser Trabeculoplasty. J Glaucoma 2021; 30:89-93. [PMID: 33351549 DOI: 10.1097/ijg.0000000000001692] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Accepted: 09/19/2020] [Indexed: 11/26/2022]
Abstract
PRECIS In African American patients with glaucoma, iStent/phacoemulsification lowered intraocular pressure and reduced glaucoma medication usage for up to 1 year, even in patients with prior selective laser trabeculoplasty (SLT). PURPOSE Currently, no studies have examined the outcomes of a trabecular microbypass stent and phacoemulsification in African American patients. Here, the authors investigate whether iStent/phacoemulsification decreases intraocular pressure (IOP) and/or medication usage in African American patients with glaucoma. They are also interested in whether prior SLT would affect outcomes of iStent/phacoemulsification. PATIENTS AND METHODS A multicenter, retrospective case series of eyes that underwent iStent/phacoemulsification between 2013 and 2017 with up to 1-year follow-up. Eyes with a confirmed diagnosis of glaucoma in African American patients were included. Eyes with neovascular glaucoma or closed angle glaucoma and eyes that underwent previous incisional glaucoma surgery were excluded. RESULTS Eighty-nine eyes were included in the study and data for 66 eyes were available at postoperative year 1 (POY1). IOP decreased from 18.3±5.7 mm Hg to 15.9±4.6 (P<0.001) and glaucoma medication usage decreased from 1.9±1.1 to 1.1±1.1 (P<0.001) at POY1. Eyes that underwent prior SLT experienced less of a decrease in IOP when compared with eyes without prior SLT, but IOP at POY1 was not significantly different between these groups. Both groups had a similar reduction in medication usage. The most common complications were IOP spikes on postoperative day 1 and microhyphemas. CONCLUSIONS In this cohort, there was a significant decrease in IOP and medication usage 1 year after iStent/phacoemulsification. iStent/phacoemulsification is an effective and safe treatment option in African American patients with glaucoma.
Collapse
|
10
|
Vold SD, Williamson BK, Hirsch L, Aminlari AE, Cho AS, Nelson C, Dickerson JE. Canaloplasty and Trabeculotomy with the OMNI System in Pseudophakic Patients with Open-Angle Glaucoma: The ROMEO Study. ACTA ACUST UNITED AC 2021; 4:173-181. [DOI: 10.1016/j.ogla.2020.10.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/30/2020] [Accepted: 10/01/2020] [Indexed: 12/11/2022]
|
11
|
Kozera M, Konopińska J, Mariak Z, Rękas M. Treatment of Open-Angle Glaucoma with iStent Implantation Combined with Phacoemulsification in Polish Caucasian Population. Clin Ophthalmol 2021; 15:473-480. [PMID: 33603324 PMCID: PMC7882442 DOI: 10.2147/opth.s293637] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Accepted: 01/26/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The aim of this investigation was to evaluate the impact of iStent (the first-generation trabecular bypass) implantation with phacoemulsification on the intraocular pressure (IOP) and glaucoma medication in subjects with mild to moderate open-angle glaucoma (OAG) and cataract in a Polish Caucasian population. Patients and Methods This prospective case series covered 78 eyes of (57 Polish Caucasian patients) that had undergone iStent implantation in conjunction with cataract surgery. Patients were surveyed preoperatively and at postoperative day 1, week 1, and months 1, 3, 6, 12, and 24. Pre- and postoperative outcome measurements included visual acuity, IOP, and medication burden. Intraoperative and postoperative complications were noted for the safety profile. For effective treatment, an IOP reduction ≥20% was assumed, regardless of the use of IOP-lowering drops. Complete surgical success was defined as an IOP ≤ 15 mmHg, medications free, and a qualified surgical success as IOP ≤ 15 mmHg with or without medications. Results Post-operatively at two years, mean IOP reduced from 18.5 mmHg to 16.1 mmHg. The mean medication burden dropped from 1.8 to 0.4 at the end of follow-up. Preoperatively, 2 (2.6%) eyes were medication free, but by postoperative month 24, 53 (68%) eyes were medication-free (p < 0.05). Effective treatment was achieved in 50 cases (64%) at the end of follow-up period. Kaplan–Meier cumulative incidence of qualified success was 51.9% after 24 months, CI95 [41.9%; 64.4%], while cumulative incidence of complete success after 2 years of observation was 35.1%, CI95 [25.9%; 47.5%]. Conclusion The iStent device combined with a cataract surgery served to decrease, significantly and positively, both IOP and medication use in the 24-months follow-up in patients with coexistent OAG and cataract in Polish patients.
Collapse
Affiliation(s)
- Milena Kozera
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland
| | - Joanna Konopińska
- Department of Ophthalmology, Medical University of Bialystok, Białystok, Poland
| | - Zofia Mariak
- Department of Ophthalmology, Medical University of Bialystok, Białystok, Poland
| | - Marek Rękas
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland
| |
Collapse
|
12
|
Swan RJ, Ferguson TJ, Shah M, Muir KW, Samuelson TW, Ahmed IIK, Lindstrom RL, Radcliffe NM, Berdahl JP. Evaluation of the IOP-Lowering Effect of a Multi-Pressure Dial at Different Negative Pressure Settings. Transl Vis Sci Technol 2020; 9:19. [PMID: 33240572 PMCID: PMC7673999 DOI: 10.1167/tvst.9.12.19] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 10/10/2020] [Indexed: 11/03/2022] Open
Abstract
Purpose To evaluate the intraocular pressure (IOP)-lowering effect of a multi-pressure dial (MPD) at targeted negative pressure settings. Methods Prospective, intrasubject controlled study of 65 healthy subjects randomized to receive no negative pressure for 60 minutes or negative pressure application at designated levels of 25%, 50%, and 75% of baseline IOP for 20 minutes each. The main outcome measure was mean IOP with application of negative pressure. Results In the study eye group, from a baseline IOP of 15.8 ± 3.6 mm Hg, the mean IOP was 13.5 ± 3.4, 11.5 ± 3.1, and 10.2 ± 2.7 mm Hg with negative pressure settings of 25%, 50% and 75%, respectively. In the control eye group, from a baseline IOP of 15.5 ± 3.0 mm Hg, the mean IOP values at the same time points, without negative pressure, were 15.6 ± 3.0, 15.5 ± 2.5 and 15.3 ± 2.4 mm Hg. The difference between the mean IOPs of the two groups was significantly different at all negative pressure settings (P < 0.001) in comparison with baseline. There was one minor adverse event, a corneal abrasion, that was unrelated to device wear. Conclusions Negative pressure application to the periocular space with a multi-pressure dial can produce titratable IOP reduction while the device is worn with active negative pressure. To our knowledge, this technology represents the first nonpharmacologic, nonlaser, nonsurgical method for IOP reduction. Translational Relevance This represents the first study demonstrating the IOP-lowering ability of the multi-pressure dial, a device that uses a novel IOP-lowering strategy by delivering negative pressure to the periocular region.
Collapse
Affiliation(s)
| | | | - Manjool Shah
- Kellogg Eye Center, University of Michigan, Ann Arbor, Michigan, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Hughes T, Traynor M. Clinical Results of Ab Interno Canaloplasty in Patients with Open-Angle Glaucoma. Clin Ophthalmol 2020; 14:3641-3650. [PMID: 33154624 PMCID: PMC7605963 DOI: 10.2147/opth.s275087] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Accepted: 09/24/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To report treatment outcomes of ab interno canaloplasty using the Visco360 and Omni system devices as a standalone procedure or combined with cataract surgery in patients with open-angle glaucoma (OAG). Design Retrospective, single-center, consecutive case series. Study Patients Eighty-nine eyes of 64 patients aged 43 to 91 with open-angle glaucoma treated with ab interno canaloplasty between January 2018 and September 2019. Eyes with previous incisional glaucoma surgery and eyes with less than 90 degrees of viscodilation were excluded. Intervention Patients underwent ab interno canaloplasty as a stand-alone procedure or in conjunction with cataract surgery. Ab interno canaloplasty was performed with either the Visco360 or Omni System devices (Sight Sciences, Menlo Park, CA). Treatment consisted of viscodilation without trabeculotomy. Main Outcome Measures Primary outcome measures were mean IOP and mean number of glaucoma medications. Additional analysis included the impact of degrees of treatment on treatment outcomes. Results Preoperative mean IOP was 24.5 ± 8.3; the number of preoperative glaucoma medications was 2.5 ± 1.3. At 18 months postoperative, the mean IOP was reduced 36% to 15.8 ± 2.5 (P<0.001) and glaucoma medications were reduced 32% to 1.7 ± 1.5 (P<0.05). Higher preoperative IOP was significantly correlated with increased IOP lowering. Reduction of mean IOP and medications were not significantly different between standalone ab interno canaloplasty vs cataract surgery/ab interno canaloplasty. Reduction of mean IOP and medications were not significantly different between patients with 180 degrees of treatment vs 360 degrees of treatment. Conclusion Ab interno canaloplasty reduces IOP and glaucoma medication use in patients with OAG whether as a standalone surgery or in combination with cataract surgery.
Collapse
|
14
|
Nitta K, Yamada Y, Morokado S, Sugiyama K. iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population. Clin Ophthalmol 2020; 14:3381-3391. [PMID: 33116389 PMCID: PMC7574908 DOI: 10.2147/opth.s274281] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 09/28/2020] [Indexed: 01/18/2023] Open
Abstract
Introduction This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent®) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (IOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6±3.0 mmHg versus 16.5±3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37±0.74 versus 1.96±0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP ≤15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8±1.4 mmHg from 14.4±3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31±0.70 versus 2.38±0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on ≥2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
Collapse
Affiliation(s)
- Koji Nitta
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Yutaro Yamada
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Satomi Morokado
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Kazuhisa Sugiyama
- Department of Ophthalmology, Kanazawa University, Kanazawa, Ishikawa Prefecture, Japan
| |
Collapse
|
15
|
Kozera M, Konopińska J, Mariak Z, Rękas M. Effectiveness of iStent Trabecular Microbypass System Combined with Phacoemulsification versus Phacoemulsification Alone in Patients with Glaucoma and Cataract Depending on the Initial Intraocular Pressure. Ophthalmic Res 2020; 64:327-336. [PMID: 32906138 DOI: 10.1159/000511456] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 09/08/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION To assess the effect of iStent trabecular microbypass implantation combined with phacoemulsification on intraocular pressure (IOP) and glaucoma medications and to compare this to outcomes of phacoemulsification alone in patients with mild to moderate primary open-angle glaucoma (POAG) depending on initial IOP. MATERIALS AND METHODS Eighty subjects with cataract and POAG were randomized 1:1 into either iStent implantation and cataract surgery (iStent group) (n = 44) or cataract surgery alone (control group) (n = 36). Groups were divided according to initial IOP (after washout period) into IOP <26 mm Hg and IOP ≥26 mm Hg. Patients were assessed preoperatively and at postoperative day 1, week 1, and months 1, 3, 6, 12, and 24. Outcome measures included best-corrected visual acuity, IOP, and glaucoma medications. RESULTS Postoperatively at 24 months, mean IOP decreased from 20.93 ± 1.28 to 17.79 ± 2.50 mm Hg in the IOP subgroup <26 mm Hg and from 26.00 ± 0.00 to 19.86 ± 2.19 in the subgroup ≥26 mm Hg in the control group. In the iStent group <26 mm Hg, IOP decreased from 22.04 ± 1.64 to 15.57 ± 2.13 mm Hg and from 26.6 ± 1.09 to 17.06 ± 2.43 mm Hg in the iStent group ≥26 mm Hg. CONCLUSION In patients with open-angle glaucoma and cataract, iStent implantation combined with cataract surgery reduced IOP significantly through 2 years, with greater reductions achieved versus phacoemulsification alone. In patients with baseline IOP <26 mm Hg, surgery reduced IOP and medication use significantly declined through 2 years, with greater reductions achieved versus patients with baseline IOP ≥26 mm Hg. The study was registered at ClinicalTrials.gov under the number NCT03807869.
Collapse
Affiliation(s)
- Milena Kozera
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland,
| | - Joanna Konopińska
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| | - Zofia Mariak
- Department of Ophthalmology, Medical University of Białystok, Białystok, Poland
| | - Marek Rękas
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland
| |
Collapse
|
16
|
Trabecular microbypass stent implantation in pseudoexfoliative glaucoma: long-term results. J Cataract Refract Surg 2020; 46:1284-1289. [DOI: 10.1097/j.jcrs.0000000000000243] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
17
|
Schweitzer JA, Hauser WH, Ibach M, Baartman B, Gollamudi SR, Crothers AW, Linn JE, Berdahl JP. Prospective Interventional Cohort Study of Ocular Surface Disease Changes in Eyes After Trabecular Micro-Bypass Stent(s) Implantation (iStent or iStent inject) with Phacoemulsification. Ophthalmol Ther 2020; 9:941-953. [PMID: 32789800 PMCID: PMC7708605 DOI: 10.1007/s40123-020-00290-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Indexed: 01/23/2023] Open
Abstract
Introduction This study sought to assess ocular surface disease changes following cataract surgery combined with trabecular micro-bypass stent(s) implantation (iStent or iStent inject). Methods This prospective interventional single-arm clinical trial enrolled 47 eyes with mild-to-moderate open-angle glaucoma (OAG) on 1–4 glaucoma medications who underwent phacoemulsification and trabecular micro-bypass stent(s) implantation. Key glaucoma and ocular surface data through 3 months postoperatively included the Ocular Surface Disease Index score (OSDI), corneal/conjunctival staining (Oxford Schema), fluorescein tear break-up time (FTBUT), conjunctival hyperemia (Efron Scale), glaucoma medications, and intraocular pressure (IOP). Results Mean OSDI scores improved from 40.1 ± 21.6 (severe) preoperatively to 17.5 ± 15.3 (mild) at 3 months (p < 0.0001). While 73% of eyes had moderate or severe OSDI scores preoperatively, 29% had such scores at 3 months, and the OSDI score was normal in 57% of eyes versus 9% preoperatively. Mean FTBUT increased from 4.3 ± 2.4 s preoperatively to 6.4 ± 2.5 s at 3 months (p < 0.0001); mean Oxford corneal/conjunctival staining reduced from 1.4 ± 1.0 preoperatively to 0.4 ± 0.6 at 3 months (p < 0.0001); mean Efron conjunctival hyperemia score reduced from 1.4 ± 0.7 preoperatively to 1.2 ± 0.6 at 3 months (p = 0.118). The number of glaucoma medications decreased from 1.5 ± 0.9 to 0.6 ± 0.8 mean medications (60% reduction, p < 0.0001), with all eyes maintaining or reducing medications versus preoperatively and 55% of eyes becoming medication-free (versus 0% preoperatively). Mean IOP reduced from 17.4 ± 4.2 mmHg to 14.5 ± 3.2 mmHg (p < 0.0001). The safety profile was excellent. Conclusion Implantation of trabecular micro-bypass stent(s) (iStent or iStent inject) with cataract surgery produced significant improvements in ocular surface health, alongside significant reductions in IOP and medications. Trial registration ClinicalTrials.gov identifier, NCT04452279.
Collapse
|
18
|
Saheb H, Donnenfeld ED, Solomon KD, Voskanyan L, Chang DF, Samuelson TW, Ahmed IIK, Katz LJ. Five-Year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (iStent®) in Open-Angle Glaucoma. Curr Eye Res 2020; 46:224-231. [PMID: 32715828 DOI: 10.1080/02713683.2020.1795881] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To assess 5-year effectiveness and safety of 2 iStent® trabecular micro-bypass stents in eyes with open-angle glaucoma (OAG) not controlled on 1 medication. MATERIALS AND METHODS This prospective, interventional, single-arm, multi-surgeon study (NCT #1252862, clinicaltrials.gov) enrolled eyes with OAG, preoperative intraocular pressure (IOP) of 18-30 mmHg on 1 ocular hypotensive medication, and 22-38 mmHg after medication washout. Eyes underwent standalone implantation of 2 iStent devices and were followed through 60 months postoperatively. Efficacy was quantified by mean diurnal IOP and medication usage. Efficacy endpoints included the proportion of eyes with ≥20% IOP reduction versus baseline unmedicated IOP (primary efficacy), and the proportion of eyes with IOP ≤18 mmHg (secondary efficacy) without medication or secondary glaucoma surgery. Safety parameters included visual acuity, cup-to-disc ratio, visual field, and complications and adverse events. RESULTS Preoperative mean IOP on 1 medication was 20.6 ± 2.0 mmHg and post-washout unmedicated IOP was 24.1 ± 1.4 mmHg (n = 39). At 5 years postoperative, medication-free mean diurnal IOP reduced to 14.5 ± 2.2 mmHg, constituting a 40% decrease versus preoperative washed-out IOP (p < .0001). In addition, this 5-year medication-free IOP constituted a 30% decrease versus preoperative IOP on 1 medication (p < .0001). At Month 60, 89.7% (26/29) of eyes achieved the primary efficacy endpoint of ≥20% IOP reduction versus baseline unmedicated IOP, and 86.2% (25/29) of eyes achieved the secondary efficacy endpoint of IOP ≤18 mmHg, without medication or secondary glaucoma surgery. Throughout follow-up, 89.7-91.3% of eyes were on no medications. Favorable safety included no secondary glaucoma surgeries, minimal adverse events, and stable visual acuity, cup-to-disc ratio, and visual fields through 5 years postoperative. CONCLUSIONS This prospective interventional study demonstrates persistent 5-year reductions in IOP and freedom from medications, together with favorable safety, following implantation of 2 first-generation trabecular micro-bypass stents in eyes with OAG on 1 preoperative medication.
Collapse
Affiliation(s)
- Hady Saheb
- Department of Ophthalmology, McGill University , Montreal, Quebec, Canada
| | - Eric D Donnenfeld
- Ophthalmic Consultants of Long Island , Rockville Centre, New York, USA
| | - Kerry D Solomon
- Carolina Eyecare Physicians , Mt Pleasant, South Carolina, USA
| | | | | | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology, University of Toronto , Toronto, Ontario, Canada
| | - L Jay Katz
- Department of Ophthalmology, Wills Eye Hospital, Jefferson Medical College , Philadelphia, Pennsylvania, USA
| |
Collapse
|
19
|
Ferguson TJ, Mechels KB, Dockter Z, Bleeker A, Ibach M, Schweitzer J, Berdahl JP. iStent Trabecular Microbypass Stent Implantation with Phacoemulsification in Patients with Open-Angle Glaucoma: 6-Year Outcomes. Clin Ophthalmol 2020; 14:1859-1866. [PMID: 32669832 PMCID: PMC7337430 DOI: 10.2147/opth.s247910] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Accepted: 04/17/2020] [Indexed: 12/13/2022] Open
Abstract
Purpose To investigate the long-term safety and efficacy of an iStent trabecular microbypass stent in combination with cataract surgery in eyes with primary open-angle glaucoma (POAG). Setting Private practice; Sioux Falls, South Dakota. Design Retrospective, consecutive case series. Methods This case series included eyes implanted with a single trabecular microbypass stent in combination with phacoemulsification in patients with mild to severe POAG. Data were collected preoperatively and at day 1, week 1, month 1, and up to 6 years postoperatively. Primary outcome measures included mean intraocular pressure (IOP) and number of glaucoma medications. Safety was noted by assessing the incidence of IOP spikes and need for additional surgery. Results The study comprised 411 eyes. Mean IOP was reduced to 14.9±4.2 mmHg compared to 18.8±5.6 mmHg at baseline at 6 years postoperative. The mean number of medications was reduced to 1.2±1.0 from 1.4±1.1 at baseline. In eyes with severe stage of disease, there was a mean IOP reduction >6 mmHg at 6 years postoperative. Eyes with baseline IOP ≥18 mmHg achieved a more robust reduction in IOP. Fifteen eyes underwent a secondary glaucoma procedure. There were no intra- or postoperative complications. Conclusion Trabecular microbypass stent implantation in combination with cataract surgery provides a sustained IOP reduction in eyes with mild-to-severe POAG. The degree of IOP reduction was more significant in eyes with higher baseline IOP and severe stage of disease.
Collapse
Affiliation(s)
| | | | - Zachary Dockter
- University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA
| | - Adam Bleeker
- University of South Dakota Sanford School of Medicine, Sioux Falls, SD, USA
| | | | | | | |
Collapse
|
20
|
The Effectiveness of First-Generation iStent Microbypass Implantation Depends on Initial Intraocular Pressure: 24-Month Follow-Up-Prospective Clinical Trial. J Ophthalmol 2020; 2020:8164703. [PMID: 32676205 PMCID: PMC7330650 DOI: 10.1155/2020/8164703] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 05/04/2020] [Accepted: 05/27/2020] [Indexed: 11/18/2022] Open
Abstract
Background Evaluation of efficacy of the iStent trabecular bypass implant in reducing intraocular pressure (IOP) depending on the value pretreatment IOP and number of medications used before surgery in patients with primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PXG) and coexisting cataract. Methods A prospective, uncontrolled, interventional case series. 72 patients, on a mean age of 72.42 ± 9.17, were divided into two groups depending on baseline IOP: group I < 26 mmHg and group II ≥ 26 mmHg. All subjects underwent ab interno implantation of a single iStent together with cataract surgery. Best-corrected visual acuity (BCVA), IOP, number of antiglaucoma medications, visual field, and number and type of complications were examined before and after surgery. Postoperative patients were followed up at 1, 7, and 30 days and 3, 6, 12, and 24 months. All the patients were washed out preoperatively as well as postoperatively. Results The mean observation time was 20 months. The mean preoperative IOP was 21.03 ± 1.44 mmHg in group I and reduced to mean 15.60 ± 2.12 mmHg after operation. In group II, mean IOP reduced from 26.00 ± 0.00 to 18.56 ± 1.81 (p=0.003). Mean glaucoma medications decreased from 1.35 ± 0.65 to 0.29 ± 0.52 in group I (p < 0.001) and from 2.89 ± 1.18 to 1.33 ± 1.50 in group II (p < 0.001). At 24 months, medication reduction was significantly greater in group I than group II (p=0.026). Conclusions Combined cataract surgery with implantation of iStent seems to be an effective procedure in patients with mild-to-moderate open-angle glaucoma and cataract. In patients with baseline IOP < 26 mmHg, surgery reduced IOP and medication use significantly declined to 2 years, with greater reductions achieved versus patients with baseline IOP ≥ 26 mmHg. This trial is registered with NCT03807869.
Collapse
|
21
|
Al Habash A, Khan O. Outcomes of Combined iStent Trabecular Micro-Bypass and Cataract Surgery for the Treatment of Open-Angle Glaucoma in a Saudi Population. Clin Ophthalmol 2020; 14:1573-1580. [PMID: 32606572 PMCID: PMC7295541 DOI: 10.2147/opth.s249261] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 04/02/2020] [Indexed: 11/27/2022] Open
Abstract
Purpose To assess the effectiveness and safety of a single iStent trabecular micro-bypass stent implantation in combination with cataract surgery in lowering the intra ocular pressure (IOP) and number of anti-glaucoma medications in Saudi patients with open-angle glaucoma (OAG). Setting King Fahad Hospital of the University, Al Khobar, Saudi Arabia. Design Prospective, non-comparative, uncontrolled, non-randomized interventional case series. Methods One iStent was implanted during phacoemulsification cataract surgery for adult patients with OAG by a single surgeon over a period of 3 years. Main outcome measures include number of anti-glaucoma medications, IOP, corrected distance visual acuity (CDVA) and complications. Results Thirty-six eyes of 33 patients with OAG underwent the surgery. The pre-operative mean IOP and mean anti-glaucoma medications were 17.47 ± 5.44 mmHg and 2.69 ± 0.92, respectively. At 1 year of follow-up mean, IOP decreased to 13.44 ± 1.99 (23.1% reduction) (P<0.001) and mean anti-glaucoma medications decreased to 1.47±1.13 (45.4% reduction) (P<0.001). Conclusion After 12-month follow-up, phacoemulsification with the implantation of a single iStent seems to be an effective and safe procedure to lower IOP and the number of anti-glaucoma medications, and to overcome the problems associated with medication nonadherence in OAG patients with cataracts.
Collapse
Affiliation(s)
- Ahmed Al Habash
- Department of Ophthalmology, College of Medicine, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Omar Khan
- Ministry of Health, Madinah, Saudi Arabia
| |
Collapse
|
22
|
iStent inject trabecular microbypass stent implantation with cataract extraction in open-angle glaucoma: early clinical experience. EYE AND VISION 2020; 7:28. [PMID: 32490028 PMCID: PMC7247162 DOI: 10.1186/s40662-020-00194-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 04/28/2020] [Indexed: 12/18/2022]
Abstract
Background Retrospective, consecutive case series to evaluate the implantation of two second-generation trabecular microbypass stents in combination with cataract surgery in a real-world, clinical setting. Methods The series included 56 eyes implanted with the iStent inject device with phacoemulsification. The series consisted of eyes with primary open-angle glaucoma (n = 52) and pseudoexfoliative glaucoma (n = 4). Primary outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included the need for secondary surgical intervention and the incidence of IOP spikes ≥10 mmHg and ≥ 15 mmHg. Results IOP was reduced by 21% to 14.7 ± 2.9 mmHg (p < 0.01) at 6 months postoperative from 18.7 ± 5.8 mmHg at baseline. Preoperatively, the mean number of glaucoma medications was 1.5 ± 0.9 and reduced by 39% to 0.9 ± 1.2 (p < 0.01) at 6 months. At 6 months, 68% of eyes had an IOP ≤15 mmHg, increased from 30% at baseline. 55% of eyes were medication-free at 6 months, up from 18% at baseline. There were no severe postoperative complications. No eyes underwent an additional glaucoma procedure. Conclusions Implantation of the iStent inject device with concomitant cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden out to 6 months postoperative. The safety profile is excellent.
Collapse
|
23
|
Berdahl J, Voskanyan L, Myers JS, Katz LJ, Samuelson TW. iStent
inject trabecular micro‐bypass stents with topical prostaglandin as standalone treatment for open‐angle glaucoma: 4‐year outcomes. Clin Exp Ophthalmol 2020; 48:767-774. [DOI: 10.1111/ceo.13763] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 04/01/2020] [Accepted: 04/09/2020] [Indexed: 01/22/2023]
Affiliation(s)
- John Berdahl
- Vance Thompson Vision Sioux Falls South Dakota USA
| | | | - Jonathan S. Myers
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
| | - L. Jay Katz
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
- Glaukos Corporation San Clemente California USA
| | | |
Collapse
|
24
|
Lindstrom R, Sarkisian SR, Lewis R, Hovanesian J, Voskanyan L. Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication. Clin Ophthalmol 2020; 14:71-80. [PMID: 32021070 PMCID: PMC6968820 DOI: 10.2147/opth.s235293] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 12/17/2019] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION This study evaluated long-term reductions in intraocular pressure (IOP) and medication following implantation of 2 second-generation trabecular micro-bypass stents (iStent inject®) in eyes with open-angle glaucoma (OAG) not controlled on 1 preoperative medication. MATERIAL AND METHODS In this prospective interventional multi-surgeon study, standalone implantation of 2 iStent inject stents was performed in 57 eyes of 57 subjects with OAG, preoperative IOP of 18-30 mmHg on 1 medication, and preoperative post-washout IOP of 22-38 mmHg. The main outcome measures included the proportions of eyes achieving medication-free IOP ≤18 mmHg, IOP ≤15 mmHg, or ≥20% IOP reduction versus preoperative unmedicated IOP. Assessments included IOP, medications, visual acuity, visual field, pachymetry, complications, and interventions. Subjects were followed for 48 months with follow-up continuing in all eyes. RESULTS At Month 48 (n=57), 95% of eyes achieved an IOP reduction of ≥20% without medication versus preoperative washout IOP; and although they had eliminated medication, 81% of eyes still had an IOP reduction of ≥20% versus preoperative IOP on 1 medication. Mean 48-month unmedicated IOP decreased by 46% to 13.2±1.6 mmHg vs 24.4±1.3 mmHg preoperatively (p<0.0001), with 95% of medication-free eyes having IOP ≤18mmHg and 82% having IOP ≤15mmHg. Over the course of follow-up, 3 eyes had medication added and 1 eye underwent a secondary glaucoma surgery, and safety parameters were favorable. DISCUSSION Standalone iStent inject implantation in OAG patients on 1 preoperative medication resulted in average IOP reduction to ≤15 mmHg with the elimination of medication and favorable safety through 48 months. TRIAL REGISTRATION ClinicalTrials.gov identifier, NCT02868190.
Collapse
Affiliation(s)
| | | | | | | | - Lilit Voskanyan
- S.V. Malayan Ophthalmology Centre, Glaucoma Department, Yerevan, Armenia
| |
Collapse
|
25
|
Neuhann R, Neuhann T. Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up. EYE AND VISION (LONDON, ENGLAND) 2020; 7:1. [PMID: 31938714 PMCID: PMC6953161 DOI: 10.1186/s40662-019-0169-7] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 12/19/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The study aimed to investigate the 24-month safety and efficacy of implantation of two second-generation iStent inject trabecular micro-bypass stents with concomitant cataract surgery. METHODS This consecutive case series included 164 eyes of 109 patients implanted with the iStent inject® device with concomitant cataract surgery. The series was comprised of eyes with primary open-angle glaucoma (n = 84), pseudoexfoliation glaucoma (n = 42), normal-tension glaucoma (n = 18), and ocular hypertension (n = 20). All 164 eyes reached 9-14 months of follow-up ("12-month consistent cohort"), with a subset of 88 eyes reaching 21-26 months of follow-up ("24-month consistent cohort"). Performance outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included intra- or postoperative complications, the need for secondary procedures and corrected distance visual acuity. Comparisons of change in continuous (e.g., IOP) and categorical (e.g., proportions of eyes on zero medications) measures between baseline and postoperative times were made with the paired t-test and McNemar's chi-squared test, respectively. RESULTS At 12 months postoperatively, IOP was reduced by 25.5% (from 20.0 ± 5.5 mmHg to 14.9 ± 2.0 mmHg; p < 0.001); at 24 months postoperatively, IOP was reduced by 26.6% (from 20.3 ± 6.1 mmHg to 14.9 ± 1.9 mmHg; p < 0.001). At 12 months postoperatively, mean number of glaucoma medications was reduced by 85.0% (from 2.0 ± 1.0 to 0.3 ± 0.8 medications; p < 0.001); at 24 months postoperatively, mean number of medications was reduced by 81.0% (from 2.1 ± 1.1 to 0.4 ± 0.8 medications; p < 0.001). After 12 months, 96.3% of eyes had an IOP ≤ 18 mmHg and 58.5% of eyes had an IOP ≤ 15 mmHg, with 81.1% of eyes free of any medication, compared to 1.8% of eyes medication-free in the 12-month cohort at baseline. After 24 months, 98.9% of eyes had an IOP ≤ 18 mmHg and 53.4% of eyes had an IOP ≤ 15 mmHg, with 72.7% free of medication compared to 1.1% of eyes medication-free in the 24-month cohort at baseline. Overall, a high safety profile was observed with no significant postoperative complications. CONCLUSIONS The insertion of iStent inject (comprised of two second-generation trabecular micro-bypass stents) with cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden up to 24 months postoperatively.
Collapse
Affiliation(s)
- Raphael Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| | - Tobias Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| |
Collapse
|
26
|
Manning D. Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery. Ophthalmol Ther 2019; 8:549-561. [PMID: 31422555 PMCID: PMC6858412 DOI: 10.1007/s40123-019-00208-x] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Indexed: 10/28/2022] Open
Abstract
INTRODUCTION This real-world retrospective case series assessed 12-month effectiveness and safety following implantation of iStent® or iStent inject® trabecular micro-bypass with cataract surgery. METHODS Consecutive patients were implanted with either iStent (comprising 1 stent) or iStent inject (comprising 2 stents), together with cataract surgery. Most patients had primary open-angle glaucoma. Effectiveness outcomes through 12 months included intraocular pressure (IOP) and glaucoma medications. Proportional analyses were completed for eyes achieving IOP ≤ 18 mmHg, IOP ≤ 15 mmHg, or IOP reduction ≥ 20% from preoperative; and eyes on 0 medications or ≥ 2 medications. Safety outcomes included adverse events, secondary surgeries, visual acuity, and visual fields. RESULTS This analysis included 137 eyes (67 iStent, 70 iStent inject) with cataract and mild to moderate glaucoma or ocular hypertension. Over 73% of eyes in both groups had early disease, and ~ 22% had prior glaucoma surgery. At 12 months postoperatively, mean IOP decreased from 18.4 ± 4.2 mmHg to 14.2 ± 2.5 mmHg in iStent eyes (p < 0.0001), and from 20.4 ± 5.6 mmHg to 14.4 ± 2.1 mmHg in iStent inject eyes (p < 0.0001). The IOP reduction was significantly greater for iStent inject eyes than iStent eyes (6.0 mmHg versus 4.2 mmHg reduction, p = 0.034). Both groups had high proportions of patients achieving the 12-month IOP endpoints, although consistently greater proportions reached these endpoints after iStent inject than iStent: 95.7% versus 92.5% had IOP ≤ 18 mmHg, respectively; 74.3% versus 71.6% had IOP ≤ 15 mmHg, respectively; and 68.6% versus 62.7% had IOP reduction ≥ 20% from baseline, respectively. Mean medication burden at 12 months decreased from 1.8 ± 0.7 to 0.3 ± 0.5 medications in iStent eyes (84.0% reduction, p < 0.0001), and from 1.3 ± 0.9 to 0.1 ± 0.3 medications in iStent inject eyes (94.7% reduction, p < 0.0001). Significantly more iStent inject eyes were medication-free at 12 months than iStent eyes (92.9% versus 76.1% medication-free, respectively; p = 0.0068). Favorable safety included few adverse events, no secondary glaucoma surgeries, and stable visual acuity and visual fields in both groups. CONCLUSION Significant and safe IOP and medication reductions were achieved through 12 months after iStent or iStent inject implantation with cataract surgery. iStent inject eyes had greater absolute IOP reduction and more eyes medication-free versus iStent eyes. FUNDING Glaukos Corporation.
Collapse
Affiliation(s)
- David Manning
- Hunter Cataract and Eye Centre, Charlestown, NSW, Australia.
| |
Collapse
|
27
|
Wang SY, Singh K, Stein JD, Chang RT. Ocular Antihypertensive Medication Use After iStent Implantation Concurrent With Cataract Surgery vs Cataract Surgery Alone in a Large US Health Care Claims Database. JAMA Ophthalmol 2019; 137:21-27. [PMID: 30267072 DOI: 10.1001/jamaophthalmol.2018.4461] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance The iStent Trabecular Micro-Bypass (Glaukos Corporation) is a minimally invasive glaucoma implant used in conjunction with cataract surgery to lower intraocular pressure. Objective To determine whether implantation of the iStent concurrent with cataract surgery is associated with reduced use of ocular antihypertensive medications in a US health care claims database. Design, Setting, and Participants Retrospective, observational longitudinal cohort study of individuals enrolled in a US managed care network who underwent iStent implantation with cataract surgery (iStent/CEIOL) from 2012 to 2016 (n = 1509 bilateral and n = 1462 unilateral surgery). A control group of individuals who underwent bilateral cataract surgery only (CEIOL) were matched 1:1 to patients undergoing bilateral iStent/CEIOL on baseline demographic and clinical factors. Data were analyzed between November 1, 2017, and January 31, 2018. Main Outcomes and Measures The number of topical ocular antihypertensive agents used postoperatively by patients undergoing iStent/CEIOL compared with baseline and with matched CEIOL control individuals, and hazard ratios with 95% confidence intervals for sustained reduced use of at least 1 topical ocular antihypertensive agent postoperatively. Results Of the 2971 eligible enrollees, mean age at first surgery was 74.3 years, and 1659 (55.8%) were women. Patients undergoing iStent/CEIOL had diagnoses that included primary open-angle glaucoma (n = 2329; 78.4%), narrow angles (n = 381; 12.8%), and secondary glaucomas (n = 261; 8.8%). At baseline, 1223 (41.2%) were receiving no topical glaucoma agents; 876 (29.5%), 437 (14.7%), and 435 (14.6%) were receiving 1, 2, or at least 3 agents, respectively. Although only 678 persons (22.8%) completed at least 2 years of postoperative follow-up, the proportion of patients receiving no drops increased postoperatively (64.7%, 20-24 months, P < .001, χ2). Patients receiving at least 1 topical agent at baseline had mean reduction of 1.01 and 0.61 medications used at 20 to 24 months with bilateral or unilateral surgery, respectively (both P < .001, paired t). Sustained reduction in glaucoma medication use was more likely in patients receiving at least 3 vs 1 medication at baseline (hazard ratio, 1.68; 95% CI, 1.36-2.09). Compared with matched control individuals undergoing CEIOL, patients undergoing bilateral iStent/CEIOL had a greater mean reduction in drops used (0.99 vs 0.49; postoperative month 20-24; P < .001; paired t) and a higher proportion receiving no drops postoperatively (73.5% vs 55.3%, postoperative month 20-24; P < .001; χ2). Conclusions and Relevance Implantation of the iStent trabecular micro-bypass stent concurrent with cataract surgery was associated with moderately reduced use of topical ocular antihypertensive medication. Reduction in the use of glaucoma medications may lessen the burden of medication adverse effects and promote better adherence.
Collapse
Affiliation(s)
- Sophia Y Wang
- Byers Eye Institute, Stanford University, Palo Alto, California
| | - Kuldev Singh
- Byers Eye Institute, Stanford University, Palo Alto, California
| | - Joshua D Stein
- Department of Ophthalmology and Visual Sciences, Center for Eye Policy and Innovation, University of Michigan, Ann Arbor.,Department of Health Management and Policy, University of Michigan, Ann Arbor
| | - Robert T Chang
- Byers Eye Institute, Stanford University, Palo Alto, California
| |
Collapse
|
28
|
Sheybani A, Scott R, Samuelson TW, Kahook MY, Bettis DI, Ahmed IIK, Stephens JD, Kent D, Ferguson TJ, Herndon LW. Open-Angle Glaucoma: Burden of Illness, Current Therapies, and the Management of Nocturnal IOP Variation. Ophthalmol Ther 2019; 9:1-14. [PMID: 31732872 PMCID: PMC7054505 DOI: 10.1007/s40123-019-00222-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Indexed: 12/19/2022] Open
Abstract
Glaucoma is a chronic, debilitating disease and a leading cause of global blindness. Despite treatment efforts, 10% of patients demonstrate loss of vision. In the US, > 80% of glaucoma cases are classified as open-angle glaucoma (OAG), with primary open-angle (POAG) being the most common. Although there has been tremendous innovation in the surgical treatment of glaucoma as of late, two clinical variants of OAG, normal-tension glaucoma (NTG) and severe POAG, are especially challenging for providers because patients with access to care and excellent treatment options may progress despite achieving a “target” intraocular pressure value. Additionally, recent research has highlighted the importance of nocturnal IOP control in avoiding glaucomatous disease progression. There remains an unmet need for new treatment options that can effectively treat NTG and severe POAG patients, irrespective of baseline IOP, while overcoming adherence limitations of current pharmacotherapies, demonstrating a robust safety profile, and more effectively controlling nocturnal IOP. Funding The Rapid Service Fees were funded by the corresponding author, Tanner J. Ferguson, MD.
Collapse
Affiliation(s)
- Arsham Sheybani
- Washington University School of Medicine, St. Louis, MO, USA
| | | | | | - Malik Y Kahook
- Department of Ophthalmology, University of Colorado Health Eye Center, Aurora, CO, USA
| | - Daniel I Bettis
- Department of Ophthalmology, Carver College of Medicine, Iowa City, IA, USA
| | | | | | | | | | - Leon W Herndon
- Duke University School of Medicine, Duke Eye Center, Durham, NC, USA
| |
Collapse
|
29
|
Ferguson TJ, Ibach M, Schweitzer J, Karpuk KL, Stephens JD, Berdahl JP. Trabecular micro‐bypass stent implantation with cataract extraction in pigmentary glaucoma. Clin Exp Ophthalmol 2019; 48:37-43. [DOI: 10.1111/ceo.13638] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 07/29/2019] [Accepted: 09/07/2019] [Indexed: 11/30/2022]
Affiliation(s)
| | - Mitch Ibach
- Vance Thompson Vision Sioux Falls South Dakota
| | | | | | | | | |
Collapse
|
30
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center. Adv Ther 2019; 36:2797-2810. [PMID: 31440981 PMCID: PMC6822971 DOI: 10.1007/s12325-019-01067-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Indexed: 11/20/2022]
Abstract
INTRODUCTION This retrospective consecutive case series assessed 12-month effectiveness and safety of iStent® or iStent inject® trabecular micro-bypass implants with cataract surgery in patients with open-angle glaucoma (OAG) in a real-world clinical setting. METHODS Effectiveness outcomes consisted of intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving IOP < 18, < 15, or < 12 mmHg; and proportional analysis of medication usage. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS This evaluation included 58 eyes with OAG (35 iStent, 23 iStent inject), with 96.6% of eyes having mild or moderate glaucoma. Diagnoses included primary open-angle glaucoma (the majority; 72.4%), pseudoexfoliative glaucoma, and pigmentary glaucoma. Baseline mean IOP and medications were statistically comparable between groups: 16.1 ± 3.6 mmHg on a mean of 1.8 ± 0.8 medications in the iStent group, and 16.2 ± 3.1 mmHg on a mean of 1.7 ± 0.8 medications in the iStent inject group. Twelve months after stent-cataract surgery, mean IOP was significantly lower in the iStent inject group than in the iStent group (13.1 mmHg vs. 15.4 mmHg, respectively; p < 0.001), and the percent reduction in IOP from baseline was significantly greater in iStent inject eyes than in iStent eyes (19.1% vs. 4.3% reduction, respectively; p < 0.001). At 12 months postoperative, significantly greater proportions of iStent inject eyes than iStent eyes achieved IOP < 18 mmHg (100% vs. 80.0% of eyes, respectively; p = 0.035), IOP < 15 mmHg (73.9% vs. 34.3% of eyes, respectively; p = 0.003), and IOP < 12 mmHg (26.1% vs. 0% of eyes, respectively; p = 0.002). Meanwhile, both groups achieved significant medication reductions at 12 months vs. baseline (94.1% reduction in iStent inject eyes, p < 0.0001; and 72.2% reduction in iStent eyes, p < 0.0001), with the percent reduction being significantly greater in iStent inject eyes than in iStent eyes (p = 0.023). At 12 months, mean number of medications was significantly lower in iStent inject eyes than iStent eyes (0.1 vs. 0.5 medications, respectively; p = 0.021), and significantly more iStent inject eyes (95.7%) than iStent eyes (71.4%) were off medications entirely (p = 0.021). A similarly high safety profile was observed in both groups. CONCLUSION iStent or iStent inject implantation with cataract surgery resulted in substantial and safe reductions in IOP and medications through 12 months postoperative. Consistent with prior observations, greater efficacy was observed with iStent inject than with iStent. FUNDING The Rapid Service Fees were funded by Glaukos Corporation.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Minas Gerais, Brazil.
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
| | | | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| |
Collapse
|
31
|
ElMallah MK, Seibold LK, Kahook MY, Williamson BK, Singh IP, Dorairaj SK. 12-Month Retrospective Comparison of Kahook Dual Blade Excisional Goniotomy with Istent Trabecular Bypass Device Implantation in Glaucomatous Eyes at the Time of Cataract Surgery. Adv Ther 2019; 36:2515-2527. [PMID: 31317390 PMCID: PMC6822852 DOI: 10.1007/s12325-019-01025-1] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Indexed: 10/30/2022]
Abstract
PURPOSE To compare the efficacy and safety of combined cataract extraction and either excisional goniotomy performed with the Kahook Dual Blade (KDB; phaco-KDB group) or single iStent trabecular bypass implantation (phaco-iStent group) in eyes with mild to moderate glaucoma and visually significant cataract. METHODS This was a retrospective analysis of 315 eyes from 230 adults with mild or moderate glaucoma treated with one or more intraocular pressure (IOP)-lowering medications (190 eyes of 134 subjects in the phaco-KDB group and 125 eyes of 96 subjects in the phaco-iStent group) that required no subsequent surgical intervention for IOP control through 12 months of follow-up. Data included best-corrected visual acuity (BCVA), IOP, and IOP-lowering medications, collected preoperatively and at 1 week and 1, 3, 6, and 12 months postoperatively as well as intraoperative and postoperative adverse events. The primary efficacy outcomes were the proportion of subjects in each group achieving ≥ 20% IOP reduction and ≥ 1 medication reduction at month 12. Subgroup analysis by baseline IOP (≤ 18 mmHg vs. > 18 mmHg) was also performed. RESULTS Mean (standard error) baseline IOP was 18.2 (0.3) mmHg in the phaco-KDB group and 16.7 (0.3) mmHg in the phaco-iStent group (p = 0.001). Statistically significant mean IOP and mean IOP medication reductions from baseline were achieved at all time points in both groups. Mean IOP reductions were significantly greater in the phaco-KDB group than in the phaco-iStent group at all time points including month 12 [- 5.0 (0.3) mmHg vs. - 2.3 (0.4) mmHg, p < 0.001], while mean medication reductions were similar between groups at all time points except week 1, when greater mean medication reduction was seen in the phaco-iStent group (- 1.23 vs. - 0.60 medications, p < 0.001). At month 12, IOP reductions ≥ 20% were achieved by 64.2% and 41.6% (p < 0.001) in the phaco-KDB and phaco-iStent groups, respectively, and IOP medication reductions of ≥ 1 medication were achieved by 80.4% and 77.4% (p = 0.522), respectively. Intraocular pressure subgroup analysis revealed significant reductions in IOP-lowering medications without compromise of IOP control in lower IOP subgroups and significant reductions in both IOP and IOP-lowering medications in the higher IOP subgroups. The most common adverse events were transient IOP elevations and transient anterior chamber inflammation, which occurred with similar frequency in both groups and resolved spontaneously. CONCLUSION Goniotomy with the KDB lowered IOP significantly more than iStent implantation, with few adverse events in both groups. In eyes with mild to moderate glaucoma undergoing combined cataract extraction and glaucoma surgery, goniotomy with the KDB can safely deliver statistically significant and clinically meaningful reductions in both IOP and IOP medication burden through 12 months of follow-up. FUNDING New World Medical, Inc., provided funding for the study, medical writing assistance, Rapid Service Fees, and the open access fee.
Collapse
|
32
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Second-Generation Trabecular Micro-Bypass Stents as Standalone Treatment for Glaucoma: A 36-Month Prospective Study. Adv Ther 2019; 36:1606-1617. [PMID: 31119690 PMCID: PMC6824385 DOI: 10.1007/s12325-019-00984-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Indexed: 11/13/2022]
Abstract
INTRODUCTION To evaluate long-term outcomes following stand-alone implantation of two second-generation trabecular micro-bypass stents (iStent inject®, Glaukos Corp., San Clemente, CA, USA) in eyes with predominantly primary open-angle glaucoma (POAG) and considerable preoperative disease burden. METHODS Eyes with POAG, pseudoexfoliative glaucoma (PXG), appositional narrow-angle glaucoma (NAG, with open-angle configuration in the area of implantation), or secondary glaucoma were included in this prospective, non-randomized, consecutive case series. All eyes underwent ab interno iStent inject implantation as a sole procedure. Assessments through 36 months included IOP, medications, corrected distance visual acuity (CDVA), secondary glaucoma surgeries, and complications and adverse events. RESULTS Two iStent inject stents were implanted in 44 consecutive eyes (POAG = 38, PXG = 4, appositional NAG = 1, secondary neovascular glaucoma = 1) of 31 patients, and 33 eyes had 36-month follow-up data. Preoperative mean IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% of eyes on 3-5 medications, no eyes medication-free, and 50% of eyes with history of prior glaucoma surgery. At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) and 87.9% of eyes achieved an IOP reduction of ≥ 20% versus preoperatively. In addition, 97% of eyes reached IOP ≤ 18 mmHg (vs. 9.1% preoperatively; p < 0.0001) and 70.0% of eyes reached IOP ≤ 15 mmHg (vs. 2.3% preoperatively; p < 0.0001). Mean medication burden decreased by 82% to 0.55 ± 0.79 (p < 0.0001), and 61% of eyes became medication-free. All eyes maintained or decreased their 36-month medication burden versus preoperatively. Safety was favorable, including minimal adverse events and stable CDVA through 36 months postoperatively. CONCLUSION This real-world cohort of glaucomatous eyes with substantial preoperative disease burden experienced significant, sustained, safe IOP and medication reductions through 36 months following stand-alone iStent inject implantation. FUNDING Article processing charges and writing assistance were provided by Glaukos Corp. (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
- Department of Ophthalmology, Buergerhospital, Frankfurt, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
33
|
Samuelson TW, Sarkisian SR, Lubeck DM, Stiles MC, Duh YJ, Romo EA, Giamporcaro JE, Hornbeak DM, Katz LJ, Bartlett W, Buznego C, Johnson S, D'Ambrosio FA, Dehning D, DuBiner H, Goyal R, Hughes B, Marquis RE, Noecker R, Tauber S, Perez BR, Roel L, Sarkisian S, Silverstein S, Day S, Solomon K, Tyson F, Vold S, Samuelson T, Simmons S, Stiles M, Nguyen QH, Bashford KP, Flowers B, Flynn WJ, Gira J, Okeke C, Reiss GR, Tyson SL, Parkhurst G, Linn J, Lubeck D, Solomon J, Singh IP, Johnson RD, Lin C, Kim JW, Crane CJ, Cotter F. Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract. Ophthalmology 2019; 126:811-821. [DOI: 10.1016/j.ophtha.2019.03.006] [Citation(s) in RCA: 94] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 03/04/2019] [Accepted: 03/04/2019] [Indexed: 10/27/2022] Open
|
34
|
Gallardo MJ, Supnet RA. Three-year outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic population with primary open-angle glaucoma. Clin Ophthalmol 2019; 13:869-879. [PMID: 31239633 PMCID: PMC6554518 DOI: 10.2147/opth.s189071] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 02/19/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: To present long-term, real-world outcomes after implanting one trabecular micro-bypass stent with cataract surgery for primary open-angle glaucoma (POAG) in a predominantly Hispanic patient population. Patients and methods: This retrospective, consecutive case series evaluated intraocular pressure (IOP), medications, and safety through 36 months after implanting one iStent® during phacoemulsification cataract surgery. Eyes were stratified into 2 subgroups classified by preoperative IOP and surgical goal. The Controlled Group had IOP <18 mmHg on ≥1 medications, and goal to reduce medications. The Uncontrolled Group had IOP ≥18 mmHg and/or maximum tolerated medication load, and goal to reduce IOP. Assessments included IOP, medications, visual fields (VF), retinal nerve fiber layer thickness (RNFL), adverse events, and secondary surgeries. Results: Of 168 total operated eyes, 87 eyes (49 Controlled, 38 Uncontrolled) completed 36 months of follow-up and comprise the Consistent Cohort in this report. At baseline, 79.6% (39/49) of Controlled eyes and 71.1% (27/38) of Uncontrolled eyes were from Hispanic patients. In the Controlled Group desiring medication reduction, mean medications were reduced by 77.3% (2.6 medications preoperatively vs 0.6 at 36 months; p<0.001. All Controlled eyes maintained or reduced medications versus preoperative; no eyes were on ≥3 medications (vs 61.2% preoperatively); and 58.3% were medication-free (vs 0% preoperatively). In the Uncontrolled Group desiring IOP reduction, mean IOP decreased by 31.2% (19.4 mmHg preoperatively vs 13.4 mmHg at 36 months; p<0.001), 91.7% of eyes achieved IOP ≤18 mmHg, 69.4% reached IOP ≤15 mmHg, and 77.8% decreased IOP ≥20% vs baseline. Uncontrolled eyes also experienced a 45.3% medication reduction (2.2 medications preoperatively vs 1.2 at 36 months; p<0.001). Favorable safety included no intraoperative complications, and stable VF and RNFL through 36 months. Conclusion: In this predominantly Hispanic patient cohort, significant IOP and medication reductions were sustained safely through 36 months after iStent implantation during cataract surgery.
Collapse
Affiliation(s)
- Mark J Gallardo
- El Paso Eye Surgeons, PA, El Paso, TX, USA.,Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | | |
Collapse
|
35
|
Fechtner RD, Voskanyan L, Vold SD, Tetz M, Auffarth G, Masood I, Au L, Khouri AS, Ahmed IIK, Saheb H. Five-Year, Prospective, Randomized, Multi-Surgeon Trial of Two Trabecular Bypass Stents versus Prostaglandin for Newly Diagnosed Open-Angle Glaucoma. Ophthalmol Glaucoma 2019; 2:156-166. [PMID: 32672584 DOI: 10.1016/j.ogla.2019.03.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 01/14/2019] [Accepted: 03/12/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate 5-year safety and efficacy of 2 trabecular micro-bypass stents versus prostaglandin as initial stand-alone treatment for newly diagnosed, treatment-naive primary open-angle glaucoma (POAG). DESIGN Prospective, randomized, controlled, multi-surgeon clinical trial. PARTICIPANTS Enrolled eyes (n = 101) were phakic and had a confirmed POAG diagnosis, normal angle anatomy, mean diurnal intraocular pressure (IOP) 21 to 40 mmHg, and vertical cup-to-disc (C:D) ratio ≤0.9. METHODS Eyes were randomized (1:1) to receive either 2 stents (iStent trabecular micro-bypass; Glaukos Corporation, San Clemente, CA) or once-daily topical travoprost. MAIN OUTCOME MEASURES The primary and secondary efficacy end points were the change from screening in mean diurnal IOP at months 12 and 24, respectively, without glaucoma surgery or add-on medication (any medication in stent eyes or a second medication in travoprost eyes). Two additional secondary end points were the proportion of eyes achieving treatment success at months 12 and 24, defined as IOP 6 to 18 mmHg without additional medication or glaucoma surgery. This report shows these efficacy measures through 60 months. Safety measures included best-corrected visual acuity, C:D ratio, visual field, pachymetry, complications, and adverse events. RESULTS Of 101 enrolled eyes (54 stent eyes, 47 travoprost eyes), 90 eyes (49 stent eyes, 41 travoprost eyes) completed 5-year follow-up. Five-year mean diurnal IOP was 16.5±1.2 mmHg in stent eyes (35.3% reduced vs. 25.5±2.5 mmHg preoperatively; P < 0.0001) and 16.3±1.9 mmHg in travoprost eyes (35.1% reduced vs. 25.1±4.6 mmHg preoperatively; P < 0.0001). During follow-up, add-on medication was initiated in 12 stent eyes (22.2% of the initial 54-eyes) and 18 travoprost eyes (38.3% of the initial 47-eyes). By 5 years, 17% (6/35) of stent eyes and 44% (14/32) of travoprost eyes needed add-on medication to control IOP (P = 0.017). Treatment success was achieved in 77% (27/35) of stent eyes and 53% (17/32) of travoprost eyes (P = 0.04). Both groups exhibited excellent safety. CONCLUSIONS This prospective randomized trial demonstrates 5-year effectiveness and safety of 2 trabecular bypass stents in patients with newly diagnosed, treatment-naive POAG, with comparably favorable outcomes as topical prostaglandin.
Collapse
Affiliation(s)
- Robert D Fechtner
- State University of New York Upstate Medical University, Syracuse, New York.
| | | | | | - Manfred Tetz
- Berlin Eye Research Institute and Augenklinik Spreebogen, Berlin, Germany
| | - Gerd Auffarth
- Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany
| | - Imran Masood
- Birmingham City Hospital, Birmingham, United Kingdom
| | - Leon Au
- Manchester Royal Eye Hospital, Manchester, United Kingdom
| | | | | | - Hady Saheb
- Mcgill University, Montreal, Quebec, Canada
| |
Collapse
|
36
|
Neuhann TH, Hornbeak DM, Neuhann RT, Giamporcaro JE. Long-term effectiveness and safety of trabecular microbypass stent implantation with cataract surgery in patients with glaucoma or ocular hypertension: Five-year outcomes. J Cataract Refract Surg 2019; 45:312-320. [DOI: 10.1016/j.jcrs.2018.10.029] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 08/13/2018] [Accepted: 10/01/2018] [Indexed: 11/28/2022]
|
37
|
Shajari M, Herrmann K, Bühren J, Vunnava P, Vounotrypidis E, Müller M, Al-Khateeb G, Kohnen T. Anterior Chamber Angle, Volume, and Depth in a Normative Cohort-A Retrospective Cross-Sectional Study. Curr Eye Res 2019; 44:632-637. [PMID: 30747543 DOI: 10.1080/02713683.2019.1576205] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Purpose: The purpose of the study was to determine the distribution of the anterior chamber angle (ACA) within a population-based study sample in Germany and to find correlations between age, sphere, and biometric parameters of the anterior chamber. Patients and Methods: A total of 500 eyes, approximately 100 eyes per decade starting with patient age of 20 years, of 463 patients with an average age of 45.2 ± 14.1 (±values subsequent represent standard deviation) years without any known history of ocular diseases, surgery, or optic nerve head excavation or hypoplasia were included. ACAs, volume, and depth were correlated to age and sphere. Scheimpflug images (Pentacam, Oculus) with automatically measured ACAs were compared to manually measured angles (Bland Altman analysis) in this healthy population. Results: The mean manually measured ACA was 26.5° ± 3.9°; the highest average angle was found in the temporal position with 28.1° ± 4.9°, while the lowest average angle was found in nasal superior position with 25.7° ± 4.7°. Statistical analysis showed an average difference of +11.4° nasal and +12.1° temporal between the automatic measurements and the manually measured angles (P < 0.01). The analysis also revealed an independent inverted correlation between age (correlation coefficient between -0.28 and -0.38) and sphere (correlation coefficient between -0.44 and -0.51) of the participants and the anterior chamber volume, angle, and anterior chamber depth (P < 0.01 for all correlations). Conclusion: The ACA width manually measured is considerably less compared to automated imaging and formerly reported values. There is a significant difference in the ACA dependent on the position of measurement (superior, nasal, inferior, and temporal) with the average angle being inversely correlated to age and sphere. Abbreviations: AC: anterior chamber ACA: anterior chamber angle ACV: anterior chamber volume ACD: anterior chamber depth AAC: acute angle closure OAG: open-angle glaucoma OCT: optical coherence tomography ACG: angle-closure glaucoma MIGS: microinvasive glaucoma surgery PACS: primary angle-closure suspects.
Collapse
Affiliation(s)
- Mehdi Shajari
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany.,b Department of Ophthalmology , LM-University , Munich , Germany
| | - Kim Herrmann
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| | - Jens Bühren
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| | - Poojita Vunnava
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| | | | - Michael Müller
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| | - Ghada Al-Khateeb
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| | - Thomas Kohnen
- a Department of Ophthalmology , Goethe-University , Frankfurt , Germany
| |
Collapse
|
38
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. Intermediate Results of iStent or iStent inject Implantation Combined with Cataract Surgery in a Real-World Setting: A Longitudinal Retrospective Study. Ophthalmol Ther 2019; 8:87-100. [PMID: 30721523 PMCID: PMC6393257 DOI: 10.1007/s40123-019-0166-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Indexed: 11/02/2022] Open
Abstract
INTRODUCTION In this real-world, retrospective, comparative study we evaluated 6-month performance and safety in consecutive eyes following implantation of the iStent® or iStent inject® trabecular micro-bypass device with concomitant cataract surgery. METHODS Performance outcomes included intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving an IOP of < 18, < 16, < 14, or < 12 mmHg; and proportions of eyes on 0, 1, 2, or ≥ 3 medications. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS A total of 73 eyes with open-angle glaucoma and cataract were included in the study; of these, 38 eyes were implanted with the iStent device and 35 were implanted with the iStent inject device. The two groups of patients had similar baseline characteristics, with the exception of mean age and medication burden (both higher in patients receiving the iStent inject device); over 90% of eyes in both groups had early glaucoma. At 6 months after surgery, mean IOP had fallen from 16.5 ± 3.9 to 13.9 ± 2.3 mmHg in eyes with the iStent implant (p < 0.001), and from 17.3 ± 3.0 to 12.7 ± 1.8 mmHg in those with the iStent inject implant (p < 0.001). This reduction was significantly greater in the iStent inject eyes than in the iStent eyes (26.6 vs. 15.8%) (p = 0.005). Significantly more eyes receiving the iStent inject device compared to the iStent device achieved an IOP of < 18 mmHg at 6 months post surgery (100 vs. 86.8%) (p = 0.033). Average medication usage was reduced from 1.8 to 0.4 medications in iStent eyes (p < 0.001) and from 2.3 to 0.4 medications in iStent inject eyes (p < 0.001). Over 70% of eyes in both groups became medication-free by 6 months post implantation. Adverse events in iStent eyes were mild and resulted in no sequelae; two iStent eyes underwent non-penetrating deep sclerectomy during follow-up. No complications or secondary surgeries were noted in iStent inject eyes. All eyes in both groups maintained or showed improved BCVA versus baseline. CONCLUSION Significant and safe IOP and medication reductions were observed after iStent or iStent inject implantation with concomitant cataract surgery. Trends toward greater effectiveness and fewer adverse events were observed with the iStent inject device compared with the iStent device. FUNDING Article processing charges were provided by Glaukos Corporation.
Collapse
Affiliation(s)
| | | | - Jonathan Clive Lake
- Cataract and Glaucoma Department, Brasilia Vision Hospital, Brasilia, DF, Brazil
| | | | | |
Collapse
|
39
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Prospective, Non-randomized, 36-Month Study of Second-Generation Trabecular Micro-Bypass Stents with Phacoemulsification in Eyes with Various Types of Glaucoma. Ophthalmol Ther 2018; 7:405-415. [PMID: 30430427 PMCID: PMC6258575 DOI: 10.1007/s40123-018-0152-8] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Indexed: 11/24/2022] Open
Abstract
Introduction The aim of this study was to assess 36-month outcomes after cataract surgery and implantation of two second-generation trabecular micro-bypass stents (iStent inject, Glaukos Corporation, San Clemente, CA, USA) into eyes with predominantly primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PEX). Methods This prospective, non-randomized, consecutive cohort study included eyes with POAG (n = 60), PEX (n = 15), appositional narrow-angle (n = 4), pigmentary (n = 1), or neovascular (secondary) (n = 1) glaucoma and cataract requiring surgery. All eyes (n = 81) underwent ab interno iStent inject implantation following cataract surgery. Effectiveness endpoints through 36 months included intraocular pressure (IOP), number of medications, and proportion of eyes with ≥ 20% IOP reduction, IOP ≤ 18 mmHg, and IOP ≤ 15 mmHg. Safety measures included corrected distance visual acuity (CDVA), adverse events, and secondary surgeries. Outcomes were evaluated for the overall cohort, and for the POAG and PEX subgroups. Results Preoperatively, 32.1% of eyes had undergone prior glaucoma surgery, 56% were on 3–4 medications, and 1 eye (1%) was medication-free. At 36 months postoperatively, mean IOP reduced by 37% (14.3 ± 1.7 mmHg versus 22.6 ± 6.2 mmHg preoperatively), and mean medication burden decreased by 68% (0.8 ± 0.9 versus 2.5 ± 1.1 medications preoperatively). IOP reduced by ≥ 20% in 78% of eyes; 100% of eyes reached IOP ≤ 18 mmHg and 71% reached ≤ 15 mmHg. Medication burden reduced considerably: 22 eyes (54%) were medication-free compared to 1 eye (1%) preoperatively; 1 eye (2%) required ≥ 3 medications compared to 45 eyes (56%) preoperatively; and 92.7% of eyes required reduced medications postoperatively. From 3 through 36 months, mean IOP remained ≤ 15.0 mmHg, and mean number of medications remained ≤ 0.9. Outcomes in the POAG and PEX subgroups included 33% and 32% lower IOP, and 68% and 64% fewer medications, respectively. iStent inject showed a favorable safety profile, including no intraoperative complications, minimal adverse events, and a stable CDVA. Conclusion This real-world cohort of eyes with various types of glaucoma and considerable disease burden exhibited durable and safe IOP and medication reductions through 36 months following iStent inject implantation with cataract surgery. Outcomes were similarly beneficial in eyes with POAG and PEX. Funding Article processing charges were funded by Glaukos Corporation (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
40
|
Shah S, Rana M, Pandey P, Masood I. Endoscopic Goniosynechialysis for Acute Angle Closure Glaucoma Following Descemet\'s Stripping Automated Endothelial Keratoplasty. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
41
|
Elbably A, Othman TM, Mousa A, Elridy M, Badawy W, Elbably M. Deep Sclerectomy with Porous Collagen in Open-angle Glaucoma, Short-term Study. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
42
|
Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018; 12:67-84. [PMID: 30473602 PMCID: PMC6236117 DOI: 10.5005/jp-journals-10008-1248] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 07/27/2018] [Indexed: 11/23/2022] Open
Abstract
Aim This meta-analysis explores the efficacy and adverse event profile of the iStent, an ab interno implant for the treatment of open-angle glaucoma. Methods A systematic literature search of Ovid MEDLINE and EMBASE was used to identify peer-reviewed original studies that provided efficacy data on the first or second generation iStent for at least five eyes. Intraocular pressure (IOP) was the primary efficacy endpoint, while the number of medication classes was the secondary outcome. Weighted mean differences were reported for continuous endpoints, while a relative risk was computed for dichotomous variables. Review Results The search revealed 545 results, of which 1767 eyes from 28 studies were included. The cohort age was 71.4 ± 5.4 years, and 44.9% of patients were male. There was a significantly greater IOP reduction after the use of two first-generation stents compared to one, irrespective of phacoemulsification status (p < 0.001). Additionally, there was a significantly greater IOP reduction following iStent alone relative to phaco-iStent for the first-generation iStent (p < 0.001) and the iStent inject (p < 0.001). For the first generation stent, combined phaco-iStent provided a greater level of IOP reduction (p < 0.001) and reduction in the number of medication classes relative to phacoemulsification alone (p < 0.001). In total, 22.5% of eyes that received iStent implantation sustained some type of adverse event. The most common adverse events were intraocular pressure elevation, stent blockage or obstruction, stent malposition and hyphema. Conclusion and Clinical Significance Statistically significant differences in efficacy outcomes exist between different numbers of stents and the presence or absence of concurrent phacoemulsification. How to cite this article: Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018;12(2):67-84.
Collapse
Affiliation(s)
- Marko Popovic
- Research Assistant, Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Xavier Campos-Moller
- Ophthalmologist, Western Health Eye Care Centre, Corner Brook, Newfoundland, Canada
| | - Hady Saheb
- Ophthalmologist, Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| | - Iqbal Ike K Ahmed
- Ophthalmologist, Department of Ophthalmology and Vision Sciences, University of Toronto, Mississauga, Ontario, Canada
| |
Collapse
|
43
|
Myers JS, Masood I, Hornbeak DM, Belda JI, Auffarth G, Jünemann A, Giamporcaro JE, Martinez-de-la-Casa JM, Ahmed IIK, Voskanyan L, Katz LJ. Prospective Evaluation of Two iStent ® Trabecular Stents, One iStent Supra ® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes. Adv Ther 2018; 35:395-407. [PMID: 29476443 PMCID: PMC5859115 DOI: 10.1007/s12325-018-0666-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Indexed: 12/01/2022]
Abstract
Introduction This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Methods Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1–3 glaucoma medications. Subjects received two iStent® trabecular micro-bypass stents, one iStent Supra® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Results Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. Conclusion IOP control was achieved safely with two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin. This microinvasive, ab interno approach introduces a possible new treatment option for refractory disease. Trial Registration NCT01456390. Funding Glaukos Corporation. Electronic supplementary material The online version of this article (10.1007/s12325-018-0666-4) contains supplementary material, which is available to authorized users.
Collapse
|
44
|
Katz LJ, Erb C, Carceller Guillamet A, Fea AM, Voskanyan L, Giamporcaro JE, Hornbeak DM. Long-term titrated IOP control with one, two, or three trabecular micro-bypass stents in open-angle glaucoma subjects on topical hypotensive medication: 42-month outcomes. Clin Ophthalmol 2018; 12:255-262. [PMID: 29440867 PMCID: PMC5798569 DOI: 10.2147/opth.s152268] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Evaluate long-term outcomes after one, two, or three trabecular micro-bypass stents implanted in a standalone procedure in eyes with open-angle glaucoma taking ocular hypotensive medication. Patients and methods Prospective randomized ongoing study of 119 subjects (109 with 42-month follow-up) with open-angle glaucoma, preoperative intraocular pressure (IOP) 18-30 mmHg on one to three glaucoma medications, and unmedicated (post-washout) IOP 22-38 mmHg. Subjects were randomized to receive one (n=38), two (n=41), or three (n=40) iStent trabecular micro-bypass stents in a standalone procedure. Postoperatively, IOP was measured with medication and annually following washout. Data included IOP, medications, gonioscopy, pachymetry, visual field, visual acuity, adverse events, and slit-lamp and fundus examinations. Results Preoperative mean medicated IOP was 19.8±1.3 mmHg on 1.71 medications in one-stent eyes, 20.1±1.6 mmHg on 1.76 medications in two-stent eyes, and 20.4±1.8 mmHg on 1.53 medications in three-stent eyes. Post-washout IOP prior to stent implantation was 25.0±1.2, 25.0±1.7, and 25.1±1.9 mmHg in the three groups, respectively. Postoperatively, Month 42 medicated IOP was 15.0±2.8, 15.7±1.0 and 14.8±1.3 mmHg in the three groups, and post-washout IOP (Months 36-37) was 17.4±0.9, 15.8±1.1 and 14.2±1.5 mmHg, respectively. IOP reduction ≥20% without medication was achieved in 89%, 90%, and 92% of one-, two-, and three-stent eyes, respectively, at Month 12; and in 61%, 91%, and 91% of eyes, respectively, at Month 42. The need for additional medication remained consistent at Months 12 and 42 in multi-stent eyes (four two-stent eyes and three three-stent eyes at both time points), whereas it increased in single-stent eyes (four eyes at Month 12 versus 18 eyes at Month 42). Safety parameters were favorable in all groups. Conclusion The standalone implantation of either single or multiple iStent® device(s) produced safe, clinically meaningful IOP and medication reductions through 42 months postoperatively, with incrementally greater and more sustained reductions in multi-stent eyes.
Collapse
Affiliation(s)
- L Jay Katz
- Glaucoma Service, Wills Eye Hospital, Philadelphia, PA, USA
| | - Carl Erb
- Glaucoma Service, Eye Clinic Wittenbergplatz, Berlin, Germany
| | | | - Antonio M Fea
- Department of Surgical Sciences, University of Torino, Torino, Italy
| | - Lilit Voskanyan
- Glaucoma Service, S. V. Malayan Ophthalmology Centre, Yerevan, Armenia
| | - Jane Ellen Giamporcaro
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| | - Dana M Hornbeak
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| |
Collapse
|
45
|
Singh K, Mutreja A, Bhattacharyya M, Dangda S, Jaisingh K. Bilateral Phacomatosis Pigmentovascularis in a Young Male with Developmental Glaucoma and Varicose Veins. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
46
|
Popovic M, Campos-Möller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1248] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
47
|
Evaluation of a Trabecular Microbypass Stent With Cataract Extraction in Severe Primary Open-angle Glaucoma. J Glaucoma 2018; 27:71-76. [DOI: 10.1097/ijg.0000000000000825] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
48
|
Teoh CS, Aquino MC, Loon SC, Chew P, Koh V. Comparing the use of phacoemulsification and combined surgery in angle-closure glaucoma. EXPERT REVIEW OF OPHTHALMOLOGY 2017. [DOI: 10.1080/17469899.2017.1379901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- CS Teoh
- Department of Ophthalmology, National University Hospital of Singapore, Singapore, Singapore
| | - MC Aquino
- Department of Ophthalmology, National University Hospital of Singapore, Singapore, Singapore
| | - SC Loon
- Department of Ophthalmology, National University Hospital of Singapore, Singapore, Singapore
| | - P Chew
- Department of Ophthalmology, National University Hospital of Singapore, Singapore, Singapore
| | - V Koh
- Department of Ophthalmology, National University Hospital of Singapore, Singapore, Singapore
| |
Collapse
|
49
|
Pillunat LE, Erb C, Jünemann AG, Kimmich F. Micro-invasive glaucoma surgery (MIGS): a review of surgical procedures using stents. Clin Ophthalmol 2017; 11:1583-1600. [PMID: 28919702 PMCID: PMC5587165 DOI: 10.2147/opth.s135316] [Citation(s) in RCA: 116] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Over the last decade several novel surgical treatment options and devices for glaucoma have been developed. All these developments aim to cause as little trauma as possible to the eye, to safely, effectively, and sustainably reduce intraocular pressure (IOP), to produce reproducible results, and to be easy to adopt. The term “micro-invasive glaucoma surgery (MIGS)” was used for summarizing all these procedures. Currently MIGS is gaining more and more interest and popularity. The possible reduction of the number of glaucoma medications, the ab interno approach without damaging the conjunctival tissue, and the probably safer procedures compared to incisional surgical methods may explain the increased interest in MIGS. The use of glaucoma drainage implants for lowering IOP in difficult-to-treat patients has been established for a long time, however, a variety of new glaucoma micro-stents are being manufactured by using various materials and are available to increase aqueous outflow via different pathways. This review summarizes published results of randomized clinical studies and extensive case report series on these devices, including Schlemm’s canal stents (iStent®, iStent® inject, Hydrus), suprachoroidal stents (CyPass®, iStent® Supra), and subconjunctival stents (XEN). The article summarizes the findings of published material on efficacy and safety for each of these approaches.
Collapse
Affiliation(s)
- Lutz E Pillunat
- Department of Ophthalmology, University Hospital Carl Gustav Carus, Dresden
| | - Carl Erb
- Augenklinik am Wittenbergplatz, Berlin, Germany
| | | | | |
Collapse
|
50
|
Safety and Efficacy of Microinvasive Glaucoma Surgery. J Ophthalmol 2017; 2017:3182935. [PMID: 28512578 PMCID: PMC5420434 DOI: 10.1155/2017/3182935] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Accepted: 03/20/2017] [Indexed: 01/27/2023] Open
Abstract
Microinvasive glaucoma surgery (MIGS) is emerging as a new therapeutic option for glaucoma patients who wish to reduce their medication burden and avoid the postoperative complications of conventional glaucoma filtration surgery. These devices differ in terms of their efficacy and safety profile. Schlemm's canal devices have the most favorable safety profile at the compromise of modest efficacy, while subconjunctival and suprachoroidal devices are potentially more effective at lowering the intraocular pressure at the expense of a higher rate of complications. This review consolidates the latest evidence on the efficacy and safety of the MIGS devices in clinical use and provides an overview on upcoming devices which would likely also become viable treatment options in the near future. These clinical data would assist a glaucoma surgeon in selecting the most appropriate MIGS device for each patient based on the glaucoma severity and patient expectations.
Collapse
|