1
|
Lazcano-Gomez G, Antzoulatos GL, Kahook MY. Combined Phacoemulsification and STREAMLINE Surgical System Canal of Schlemm Transluminal Dilation in Eyes of Hispanic Patients with Mild to Moderate Glaucoma. Clin Ophthalmol 2023; 17:1911-1918. [PMID: 37425029 PMCID: PMC10329431 DOI: 10.2147/opth.s409164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/08/2023] [Indexed: 07/11/2023] Open
Abstract
Purpose To characterize clinical outcomes of transluminal dilation of the canal of Schlemm using the STREAMLINE Surgical System combined with phacoemulsification in eyes of Hispanic patients diagnosed with mild to moderate primary open-angle glaucoma. Methods This was a prospective analysis of all cases performed and followed up to 12 months. All eyes underwent medication washout preoperatively. Reduction in intraocular pressure (IOP) from unmedicated baseline, as well as medications from pre-washout baseline, were analyzed at postoperative Day 1, Week 1, and Months 1, 3, 6, 9, and 12. Results All 37 patients were Hispanic, 83.8% were female, and mean (standard deviation) age was 66.0 (10.5) years. Mean medicated preoperative IOP was 16.9 (3.2) mmHg using a mean of 2.1 (0.9) medications, unmedicated baseline IOP (after washout) was 23.2 (2.3) mmHg, and mean IOP at every postoperative study visit was significantly lower (p<0.0002). Mean IOP from month 1 through the first postoperative year ranged from 14.7-16.2 mmHg, representing a reduction of 7.0-8.5 mmHg (30.7-36.5%). At month 12, 80% of all eyes (28/35) and 77.8% of medication-free eyes (14/18) had IOP reduction ≥20% from unmedicated baseline, and 51.4% of eyes (18/35) were medication-free. Mean medication use was significantly reduced (by 59.9-74.6%, p<0.0001) at every postoperative study visit. The only adverse event occurring in >1 eye was high IOP (n=4) which was responsive to topical medical therapy; no adverse events were attributed to the transluminal dilation procedure. Conclusion Transluminal dilation of the canal of Schlemm using the STREAMLINE Surgical System combined with phacoemulsification safely and effectively reduced both IOP and dependence on IOP-lowering medications in a Hispanic population diagnosed with POAG and should be considered at the time of phacoemulsification in Hispanic patients who have a need for IOP reduction, medication reduction, or both.
Collapse
Affiliation(s)
- Gabriel Lazcano-Gomez
- Department of Glaucoma, Clinica Laser y Ultrasonido Ocular, Puebla City, Puebla, Mexico
- Hospital Angeles Puebla, Puebla City, Puebla, Mexico
| | | | - Malik Y Kahook
- Department of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA
| |
Collapse
|
2
|
Lima FE, Geraissate JC, Ávila MP. A multicenter prospective comparative study evaluating cataract surgery and endoscopic cyclophotocoagulation either with or without iStent inject implantation in Brazilian patients with glaucoma. Int Ophthalmol 2022; 43:1665-1676. [PMID: 36273360 PMCID: PMC10149466 DOI: 10.1007/s10792-022-02563-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 10/10/2022] [Indexed: 11/24/2022]
Abstract
Abstract
Purpose
Compare 12-month (12 M) safety and efficacy of endoscopic cyclophotocoagulation (ECP) + cataract surgery (Group 1) versus ECP + cataract surgery + iStent inject trabecular micro-bypass implantation (Group 2) in Brazilian patients with open-angle glaucoma (OAG).
Methods
This prospective, multicenter, comparative case series included patients with OAG and cataract who were randomized to receive treatment in Group 1 or Group 2. Outcomes included mean and percent reduction versus preoperative in intraocular pressure (IOP) and number of glaucoma medications; visual acuity; occurrence of adverse events; and rate of secondary surgeries.
Results
Preoperatively, Groups 1 and 2 had similar mean IOP (mean ± standard deviation 22.1 ± 3.6 and 22.0 ± 2.5 mmHg, respectively) and mean number of medications (3.3 ± 0.6 and 3.4 ± 0.6 medications, respectively). At all follow-up timepoints through 12 M, both groups achieved significant IOP and medication reductions versus preoperative (IOP p < 0.001 and number of medications p < 0.001 for both groups). At 12 M, IOP reductions were 24.2% (Group 1) and 43.6% (Group 2) (p < 0.001); mean medication reductions were 50.2% and 71.5%, respectively. Mean postoperative IOP and number of medications were higher in Group 1 than Group 2 (IOP p < 0.01 all visits, medication p < 0.01 at 6 M and 12 M). Adverse events were generally mild and infrequent in both groups.
Conclusion
Both treatment groups (ECP + phacoemulsification, with/without iStent inject implantation) achieved significant and safe reductions in IOP and medications versus preoperative in Brazilian OAG patients. Percent reductions were significantly greater, and mean IOP and medications were significantly lower, in the group receiving iStent inject.
Clinical trial registration (CTR)
CAAE project identification #20053019.5.0000.5078. Protocol #3.587.147. Clinical Trial Database of the Federal University of Goiás, Brazil. Registration Date: September 19, 2019.
Collapse
Affiliation(s)
- Francisco E. Lima
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
| | - João C. Geraissate
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| | - Marcos P. Ávila
- Federal University of Goiás, Goiânia, Brazil
- Centro Brasileiro de Cirurgia de Olhos, Avenida T-2 número 401, Setor Bueno, Goiânia, 74210-010 Brazil
- Centro Brasileiro da Visão, Brasília, Brazil
| |
Collapse
|
3
|
Manning DK, Haider A, Clement C, Viswanathan D. Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction. J Curr Glaucoma Pract 2022; 16:105-110. [PMID: 36128086 PMCID: PMC9452712 DOI: 10.5005/jp-journals-10078-1374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Accepted: 03/21/2022] [Indexed: 11/23/2022] Open
Abstract
Aim To describe the efficacy and safety of iStent implantation prior to phacoemulsification in manual as well as femtosecond laser-assisted cataract surgery (FLACS), and highlight this approach as a reasonable, if not necessary, step to advance one's ability and confidence in the use of microinvasive glaucoma surgery (MIGS) technology in phakic patients. Methods A retrospective consecutive case series of patients with open angle glaucoma or ocular hypertension who underwent iStent inject implantation followed by cataract surgery (manual or FLACS). All cases underwent postoperative video review and were assessed and classified for intraoperative lens injury and hyphaema. Postoperative data included intraocular pressure (IOP), medication usage and adverse events. Results Sixty-three eyes (n = 40 manual, n = 23 FLACS) were analyzed. Preoperatively, the mean IOP was 19.2 ± 4.9 mm Hg on 1.4 ± 0.96 mean medications, with 100% of eyes treated with medication. Intraoperatively, no lens injury was identified, and no significant hyphaema that impeded surgery occurred. At 6 months postoperative, mean IOP was 14.2 ± 1.8 mm Hg (38% reduction: p < 0.001), and >90% of eyes had IOP ≤ 16 mm Hg. The mean number of medications reduced to 0.11 ± 0.3 (92% reduction: p < 0.001), with 89% of eyes medication free. Safety was excellent for both manual and FLACS, with two iStents implanted in all eyes, and no cases of significant hyphaema or lens injury. Conclusion Early implantation is safe, maximizes corneal clarity and angle visualization, avoids the risk of non-implantation due to surgical complications, and has a high success rate in both manual cataract surgery and the setting of FLACS. Clinical significance The conventional recommended approach of iStent implantation following cataract extraction has been adopted by many, however, with the advent of stand-alone procedures and concern about potential lens injury, there is an opportunity to gain experience with minimal risk in patients undergoing MIGS procedures combined with cataract surgery by implanting iStents at the start of the procedure. There is currently little emphasis or data published in the literature on an early approach to implantation to guide surgeons. How to cite this article Manning DK, Haider A, Clement C, et al. Efficacy and Safety of iStent Inject Implantation in Manual and Femtosecond Laser-assisted Cataract Surgery before Lens Extraction. J Curr Glaucoma Pract 2022;16(2):105-110.
Collapse
Affiliation(s)
- David Kevin Manning
- Department of Ophthalmology, Hunter Cataract and Eye Centre, Charlestown, New South Wales, Australia
- David Kevin Manning, Department of Ophthalmology, Hunter Cataract and Eye Centre, Charlestown, New South Wales, Australia, Phone: +61242906911, e-mail:
| | - Ali Haider
- Department of Ophthalmology, Hunter New England Health, Newcastle, New South Wales, Australia
| | - Colin Clement
- Glaucoma Unit, Sydney Eye Hospital, Sydney, New South Wales, Australia
| | - Deepa Viswanathan
- Department of Ophthalmology, Hunter New England Health, Newcastle, New South Wales, Australia
| |
Collapse
|
4
|
Gallardo MJ, Dhamdhere K, Dickerson JE. Canaloplasty and Trabeculotomy Ab Interno Combined with Cataract Surgery: 12-Month Outcomes in Hispanic Patients with Open-Angle Glaucoma. Clin Ophthalmol 2022; 16:905-908. [PMID: 35356700 PMCID: PMC8959719 DOI: 10.2147/opth.s358878] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 03/15/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
| | - Kavita Dhamdhere
- Sight Sciences Inc., Menlo Park, CA, USA.,Mahatma Gandhi Medical College and Research Center, Wardha, India
| | - Jaime E Dickerson
- Sight Sciences Inc., Menlo Park, CA, USA.,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| |
Collapse
|
5
|
Jabłońska J, Lewczuk K, Konopińska J, Mariak Z, Rękas M. Microinvasive glaucoma surgery: a review and classification of implant-dependent procedures and techniques. Acta Ophthalmol 2022; 100:e327-e338. [PMID: 33988310 PMCID: PMC9291507 DOI: 10.1111/aos.14906] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 03/08/2021] [Accepted: 04/22/2021] [Indexed: 12/25/2022]
Abstract
The aim of this article is to discuss how physiology and anatomical background affect the effectiveness of implant‐dependent microinvasive glaucoma surgery (MIGS). First, we provide a micro view of aqueous outflow and tissue behaviour. Second, we review studies exploring the mechanisms of the pressure‐lowering effect of MIGS, as well as tissue behaviour during aqueous flow and tissue motion. We also describe and classify microinvasive surgical procedures and the most important types of implants, as well as their mechanisms of action, implantation techniques and efficacy. Further, we summarize the indications and surgical results presented in recent studies, providing an evidence‐based update on novel and emerging MIGS techniques for the treatment of open‐angle glaucoma. These data can help surgeons to personalize the management of glaucoma and to choose the best MIGS option for individual glaucoma patients.
Collapse
Affiliation(s)
- Joanna Jabłońska
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Katarzyna Lewczuk
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| | - Joanna Konopińska
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Zofia Mariak
- Department of Ophthalmology Medical University of Bialystok Białystok Poland
| | - Marek Rękas
- Department of Ophthalmology Military Institute of Medicine Warsaw Poland
| |
Collapse
|
6
|
Trabecular Microbypass Stent and Phacoemulsification in African American Patients With Open-angle Glaucoma: Outcomes and Effect of Prior Laser Trabeculoplasty. J Glaucoma 2021; 30:89-93. [PMID: 33351549 DOI: 10.1097/ijg.0000000000001692] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2020] [Accepted: 09/19/2020] [Indexed: 11/26/2022]
Abstract
PRECIS In African American patients with glaucoma, iStent/phacoemulsification lowered intraocular pressure and reduced glaucoma medication usage for up to 1 year, even in patients with prior selective laser trabeculoplasty (SLT). PURPOSE Currently, no studies have examined the outcomes of a trabecular microbypass stent and phacoemulsification in African American patients. Here, the authors investigate whether iStent/phacoemulsification decreases intraocular pressure (IOP) and/or medication usage in African American patients with glaucoma. They are also interested in whether prior SLT would affect outcomes of iStent/phacoemulsification. PATIENTS AND METHODS A multicenter, retrospective case series of eyes that underwent iStent/phacoemulsification between 2013 and 2017 with up to 1-year follow-up. Eyes with a confirmed diagnosis of glaucoma in African American patients were included. Eyes with neovascular glaucoma or closed angle glaucoma and eyes that underwent previous incisional glaucoma surgery were excluded. RESULTS Eighty-nine eyes were included in the study and data for 66 eyes were available at postoperative year 1 (POY1). IOP decreased from 18.3±5.7 mm Hg to 15.9±4.6 (P<0.001) and glaucoma medication usage decreased from 1.9±1.1 to 1.1±1.1 (P<0.001) at POY1. Eyes that underwent prior SLT experienced less of a decrease in IOP when compared with eyes without prior SLT, but IOP at POY1 was not significantly different between these groups. Both groups had a similar reduction in medication usage. The most common complications were IOP spikes on postoperative day 1 and microhyphemas. CONCLUSIONS In this cohort, there was a significant decrease in IOP and medication usage 1 year after iStent/phacoemulsification. iStent/phacoemulsification is an effective and safe treatment option in African American patients with glaucoma.
Collapse
|
7
|
Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis. J Glaucoma 2021; 30:606-620. [PMID: 33596009 DOI: 10.1097/ijg.0000000000001805] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 01/07/2021] [Indexed: 11/25/2022]
Abstract
PRECIS Standalone trabecular micro-bypass glaucoma surgery with the iStent devices is associated with clinically relevant reductions in intraocular pressure (IOP) sustained over a reasonably long-term while simultaneously reducing medication burden and a relatively favorable safety profile. PURPOSE While there is a relatively large body of evidence supporting the implantation of the iStent trabecular micro-bypass devices during phacoemulsification in patients with open-angle glaucoma (OAG), its efficacy as a standalone procedure has been less widely reported. The aims of this study were to systematically identify and quantitatively evaluate the efficacy of iStent devices (iStent and iStent inject) when performed independently of cataract surgery in patients with OAG. METHODS A systematic review of the literature was undertaken in August 2019 to identify studies of standalone trabecular micro-bypass glaucoma surgery with iStent devices in patients with OAG. All randomized trials were considered and nonrandomized studies that included at least 6 months of follow-up or more than 10 eyes. Key efficacy analyses included postoperative IOP and medication use, which were used to evaluate weighted mean differences from baseline, and the proportion of eyes free of ocular medication. Postoperative adverse events were descriptively summarized. RESULTS A total of 13 studies were identified including 4 randomized controlled trials and 9 nonrandomized or single-arm studies providing data for 778 eyes. In eyes implanted with iStent devices, a weighted mean IOP reduction of 31.1% was observed at 6 to 12 months. In studies reporting longer-term outcomes (36 to 48 mo or 60 mo), the weighted mean IOP reduction was 30.4% and 32.9%, respectively. The pooled weighted mean reduction in IOP from baseline across all studies at 6 to 12 months and 36 to 60 months poststent implantation was 7.01 mm Hg (95% confidence interval: 5.91, 8.11) and 6.59 mm Hg (95% confidence interval: 5.55, 7.63), respectively. Medication burden was reduced by ~1.0 medication at 6 to 18 months and 1.2 medications at 36 to 60 months. Adverse events reported in more than 5% of participants were progression of pre-existing cataract/cataract surgery and loss of best-corrected visual acuity but these rates were no different to those reported in comparator medical therapy study arms. CONCLUSIONS The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.
Collapse
|
8
|
Kozera M, Konopińska J, Mariak Z, Rękas M. Treatment of Open-Angle Glaucoma with iStent Implantation Combined with Phacoemulsification in Polish Caucasian Population. Clin Ophthalmol 2021; 15:473-480. [PMID: 33603324 PMCID: PMC7882442 DOI: 10.2147/opth.s293637] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Accepted: 01/26/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The aim of this investigation was to evaluate the impact of iStent (the first-generation trabecular bypass) implantation with phacoemulsification on the intraocular pressure (IOP) and glaucoma medication in subjects with mild to moderate open-angle glaucoma (OAG) and cataract in a Polish Caucasian population. Patients and Methods This prospective case series covered 78 eyes of (57 Polish Caucasian patients) that had undergone iStent implantation in conjunction with cataract surgery. Patients were surveyed preoperatively and at postoperative day 1, week 1, and months 1, 3, 6, 12, and 24. Pre- and postoperative outcome measurements included visual acuity, IOP, and medication burden. Intraoperative and postoperative complications were noted for the safety profile. For effective treatment, an IOP reduction ≥20% was assumed, regardless of the use of IOP-lowering drops. Complete surgical success was defined as an IOP ≤ 15 mmHg, medications free, and a qualified surgical success as IOP ≤ 15 mmHg with or without medications. Results Post-operatively at two years, mean IOP reduced from 18.5 mmHg to 16.1 mmHg. The mean medication burden dropped from 1.8 to 0.4 at the end of follow-up. Preoperatively, 2 (2.6%) eyes were medication free, but by postoperative month 24, 53 (68%) eyes were medication-free (p < 0.05). Effective treatment was achieved in 50 cases (64%) at the end of follow-up period. Kaplan–Meier cumulative incidence of qualified success was 51.9% after 24 months, CI95 [41.9%; 64.4%], while cumulative incidence of complete success after 2 years of observation was 35.1%, CI95 [25.9%; 47.5%]. Conclusion The iStent device combined with a cataract surgery served to decrease, significantly and positively, both IOP and medication use in the 24-months follow-up in patients with coexistent OAG and cataract in Polish patients.
Collapse
Affiliation(s)
- Milena Kozera
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland
| | - Joanna Konopińska
- Department of Ophthalmology, Medical University of Bialystok, Białystok, Poland
| | - Zofia Mariak
- Department of Ophthalmology, Medical University of Bialystok, Białystok, Poland
| | - Marek Rękas
- Department of Ophthalmology, Military Institute of Medicine, Warsaw, Poland
| |
Collapse
|
9
|
Porter M, Garza A, Gallardo M. Excisional Goniotomy in Latino Patients with Open-Angle Glaucoma: Outcomes Through 24 Months. Clin Ophthalmol 2020; 14:3619-3625. [PMID: 33154621 PMCID: PMC7608600 DOI: 10.2147/opth.s271923] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 09/08/2020] [Indexed: 12/27/2022] Open
Abstract
Purpose To characterize the efficacy of combined phacoemulsification and excisional goniotomy with the Kahook Dual Blade (KDB-phaco) in eyes of Latino adults with cataract and open-angle glaucoma (OAG). Methods Health records of consecutive Latino patients undergoing KDB-phaco were retrospectively reviewed. Intraocular pressure (IOP) and IOP-lowering medication use were recorded at baseline and each postoperative visit through up to 24 months. Primary outcomes were reductions in IOP and medication use from baseline; secondary outcomes were the proportions of eyes achieving IOP reductions of ≥20% and medication reductions ≥1 medication from baseline. Subgroup analysis was conducted in eyes with high and low baseline IOP. Results Data from 44 eyes of 32 Latino patients with OAG were analyzed. Mean IOP was 17.8 (0.7) mmHg at baseline and postoperatively ranged from 12.4 to 13.8 mmHg (p≥0.0003), representing mean IOP reductions of 4.2–4.6 mmHg (19.7–23.1%). Mean medication was 1.5 (0.2) medications per eye at baseline and postoperatively ranged from 0.2 to 1.0 (p≥0.0061), representing mean medication reductions of 0.7–1.2 medications per eye (47.1–87.2%). In the low baseline IOP group (<18 mmHg), mean IOP was significantly reduced through Month 24 and medications through Month 12; in the high baseline IOP group (≥18 mmHg), IOP and medications were significantly reduced through Month 24. From Months 1–24, IOP reductions of ≥20% were achieved by 48.4–56.2% of eyes in the full cohort, by 20.0–33.3% in the low IOP group, and by 66.7–100% in the high IOP group; medication reductions of ≥1 medication were achieved by 72.0–95.6%, 64.7–94.2%, and 87.5–100% of eyes, respectively. Conclusion Combined KDB-phaco in eyes of Latino patients with glaucoma and cataract significantly lowers IOP and the need for IOP-lowering medications for up to 24 months and should be considered for such patients who warrant IOP reduction, medication reduction, or both.
Collapse
Affiliation(s)
- Matthew Porter
- Private Practice, El Paso Eye Surgeons, P.A., El Paso, Texas, USA.,Texas Tech University Health Sciences Center School of Medicine-Lubbock, Lubbock, TX, USA
| | - Arnulfo Garza
- Texas Tech University Paul L. Foster School of Medicine, Lubbock, TX, USA
| | - Mark Gallardo
- Private Practice, El Paso Eye Surgeons, P.A., El Paso, Texas, USA
| |
Collapse
|
10
|
Saheb H, Donnenfeld ED, Solomon KD, Voskanyan L, Chang DF, Samuelson TW, Ahmed IIK, Katz LJ. Five-Year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (iStent®) in Open-Angle Glaucoma. Curr Eye Res 2020; 46:224-231. [PMID: 32715828 DOI: 10.1080/02713683.2020.1795881] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To assess 5-year effectiveness and safety of 2 iStent® trabecular micro-bypass stents in eyes with open-angle glaucoma (OAG) not controlled on 1 medication. MATERIALS AND METHODS This prospective, interventional, single-arm, multi-surgeon study (NCT #1252862, clinicaltrials.gov) enrolled eyes with OAG, preoperative intraocular pressure (IOP) of 18-30 mmHg on 1 ocular hypotensive medication, and 22-38 mmHg after medication washout. Eyes underwent standalone implantation of 2 iStent devices and were followed through 60 months postoperatively. Efficacy was quantified by mean diurnal IOP and medication usage. Efficacy endpoints included the proportion of eyes with ≥20% IOP reduction versus baseline unmedicated IOP (primary efficacy), and the proportion of eyes with IOP ≤18 mmHg (secondary efficacy) without medication or secondary glaucoma surgery. Safety parameters included visual acuity, cup-to-disc ratio, visual field, and complications and adverse events. RESULTS Preoperative mean IOP on 1 medication was 20.6 ± 2.0 mmHg and post-washout unmedicated IOP was 24.1 ± 1.4 mmHg (n = 39). At 5 years postoperative, medication-free mean diurnal IOP reduced to 14.5 ± 2.2 mmHg, constituting a 40% decrease versus preoperative washed-out IOP (p < .0001). In addition, this 5-year medication-free IOP constituted a 30% decrease versus preoperative IOP on 1 medication (p < .0001). At Month 60, 89.7% (26/29) of eyes achieved the primary efficacy endpoint of ≥20% IOP reduction versus baseline unmedicated IOP, and 86.2% (25/29) of eyes achieved the secondary efficacy endpoint of IOP ≤18 mmHg, without medication or secondary glaucoma surgery. Throughout follow-up, 89.7-91.3% of eyes were on no medications. Favorable safety included no secondary glaucoma surgeries, minimal adverse events, and stable visual acuity, cup-to-disc ratio, and visual fields through 5 years postoperative. CONCLUSIONS This prospective interventional study demonstrates persistent 5-year reductions in IOP and freedom from medications, together with favorable safety, following implantation of 2 first-generation trabecular micro-bypass stents in eyes with OAG on 1 preoperative medication.
Collapse
Affiliation(s)
- Hady Saheb
- Department of Ophthalmology, McGill University , Montreal, Quebec, Canada
| | - Eric D Donnenfeld
- Ophthalmic Consultants of Long Island , Rockville Centre, New York, USA
| | - Kerry D Solomon
- Carolina Eyecare Physicians , Mt Pleasant, South Carolina, USA
| | | | | | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology, University of Toronto , Toronto, Ontario, Canada
| | - L Jay Katz
- Department of Ophthalmology, Wills Eye Hospital, Jefferson Medical College , Philadelphia, Pennsylvania, USA
| |
Collapse
|
11
|
Lindstrom R, Sarkisian SR, Lewis R, Hovanesian J, Voskanyan L. Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication. Clin Ophthalmol 2020; 14:71-80. [PMID: 32021070 PMCID: PMC6968820 DOI: 10.2147/opth.s235293] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 12/17/2019] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION This study evaluated long-term reductions in intraocular pressure (IOP) and medication following implantation of 2 second-generation trabecular micro-bypass stents (iStent inject®) in eyes with open-angle glaucoma (OAG) not controlled on 1 preoperative medication. MATERIAL AND METHODS In this prospective interventional multi-surgeon study, standalone implantation of 2 iStent inject stents was performed in 57 eyes of 57 subjects with OAG, preoperative IOP of 18-30 mmHg on 1 medication, and preoperative post-washout IOP of 22-38 mmHg. The main outcome measures included the proportions of eyes achieving medication-free IOP ≤18 mmHg, IOP ≤15 mmHg, or ≥20% IOP reduction versus preoperative unmedicated IOP. Assessments included IOP, medications, visual acuity, visual field, pachymetry, complications, and interventions. Subjects were followed for 48 months with follow-up continuing in all eyes. RESULTS At Month 48 (n=57), 95% of eyes achieved an IOP reduction of ≥20% without medication versus preoperative washout IOP; and although they had eliminated medication, 81% of eyes still had an IOP reduction of ≥20% versus preoperative IOP on 1 medication. Mean 48-month unmedicated IOP decreased by 46% to 13.2±1.6 mmHg vs 24.4±1.3 mmHg preoperatively (p<0.0001), with 95% of medication-free eyes having IOP ≤18mmHg and 82% having IOP ≤15mmHg. Over the course of follow-up, 3 eyes had medication added and 1 eye underwent a secondary glaucoma surgery, and safety parameters were favorable. DISCUSSION Standalone iStent inject implantation in OAG patients on 1 preoperative medication resulted in average IOP reduction to ≤15 mmHg with the elimination of medication and favorable safety through 48 months. TRIAL REGISTRATION ClinicalTrials.gov identifier, NCT02868190.
Collapse
Affiliation(s)
| | | | | | | | - Lilit Voskanyan
- S.V. Malayan Ophthalmology Centre, Glaucoma Department, Yerevan, Armenia
| |
Collapse
|
12
|
Neuhann R, Neuhann T. Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up. EYE AND VISION (LONDON, ENGLAND) 2020; 7:1. [PMID: 31938714 PMCID: PMC6953161 DOI: 10.1186/s40662-019-0169-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 12/19/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The study aimed to investigate the 24-month safety and efficacy of implantation of two second-generation iStent inject trabecular micro-bypass stents with concomitant cataract surgery. METHODS This consecutive case series included 164 eyes of 109 patients implanted with the iStent inject® device with concomitant cataract surgery. The series was comprised of eyes with primary open-angle glaucoma (n = 84), pseudoexfoliation glaucoma (n = 42), normal-tension glaucoma (n = 18), and ocular hypertension (n = 20). All 164 eyes reached 9-14 months of follow-up ("12-month consistent cohort"), with a subset of 88 eyes reaching 21-26 months of follow-up ("24-month consistent cohort"). Performance outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included intra- or postoperative complications, the need for secondary procedures and corrected distance visual acuity. Comparisons of change in continuous (e.g., IOP) and categorical (e.g., proportions of eyes on zero medications) measures between baseline and postoperative times were made with the paired t-test and McNemar's chi-squared test, respectively. RESULTS At 12 months postoperatively, IOP was reduced by 25.5% (from 20.0 ± 5.5 mmHg to 14.9 ± 2.0 mmHg; p < 0.001); at 24 months postoperatively, IOP was reduced by 26.6% (from 20.3 ± 6.1 mmHg to 14.9 ± 1.9 mmHg; p < 0.001). At 12 months postoperatively, mean number of glaucoma medications was reduced by 85.0% (from 2.0 ± 1.0 to 0.3 ± 0.8 medications; p < 0.001); at 24 months postoperatively, mean number of medications was reduced by 81.0% (from 2.1 ± 1.1 to 0.4 ± 0.8 medications; p < 0.001). After 12 months, 96.3% of eyes had an IOP ≤ 18 mmHg and 58.5% of eyes had an IOP ≤ 15 mmHg, with 81.1% of eyes free of any medication, compared to 1.8% of eyes medication-free in the 12-month cohort at baseline. After 24 months, 98.9% of eyes had an IOP ≤ 18 mmHg and 53.4% of eyes had an IOP ≤ 15 mmHg, with 72.7% free of medication compared to 1.1% of eyes medication-free in the 24-month cohort at baseline. Overall, a high safety profile was observed with no significant postoperative complications. CONCLUSIONS The insertion of iStent inject (comprised of two second-generation trabecular micro-bypass stents) with cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden up to 24 months postoperatively.
Collapse
Affiliation(s)
- Raphael Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| | - Tobias Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| |
Collapse
|
13
|
Manning D. Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery. Ophthalmol Ther 2019; 8:549-561. [PMID: 31422555 PMCID: PMC6858412 DOI: 10.1007/s40123-019-00208-x] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Indexed: 10/28/2022] Open
Abstract
INTRODUCTION This real-world retrospective case series assessed 12-month effectiveness and safety following implantation of iStent® or iStent inject® trabecular micro-bypass with cataract surgery. METHODS Consecutive patients were implanted with either iStent (comprising 1 stent) or iStent inject (comprising 2 stents), together with cataract surgery. Most patients had primary open-angle glaucoma. Effectiveness outcomes through 12 months included intraocular pressure (IOP) and glaucoma medications. Proportional analyses were completed for eyes achieving IOP ≤ 18 mmHg, IOP ≤ 15 mmHg, or IOP reduction ≥ 20% from preoperative; and eyes on 0 medications or ≥ 2 medications. Safety outcomes included adverse events, secondary surgeries, visual acuity, and visual fields. RESULTS This analysis included 137 eyes (67 iStent, 70 iStent inject) with cataract and mild to moderate glaucoma or ocular hypertension. Over 73% of eyes in both groups had early disease, and ~ 22% had prior glaucoma surgery. At 12 months postoperatively, mean IOP decreased from 18.4 ± 4.2 mmHg to 14.2 ± 2.5 mmHg in iStent eyes (p < 0.0001), and from 20.4 ± 5.6 mmHg to 14.4 ± 2.1 mmHg in iStent inject eyes (p < 0.0001). The IOP reduction was significantly greater for iStent inject eyes than iStent eyes (6.0 mmHg versus 4.2 mmHg reduction, p = 0.034). Both groups had high proportions of patients achieving the 12-month IOP endpoints, although consistently greater proportions reached these endpoints after iStent inject than iStent: 95.7% versus 92.5% had IOP ≤ 18 mmHg, respectively; 74.3% versus 71.6% had IOP ≤ 15 mmHg, respectively; and 68.6% versus 62.7% had IOP reduction ≥ 20% from baseline, respectively. Mean medication burden at 12 months decreased from 1.8 ± 0.7 to 0.3 ± 0.5 medications in iStent eyes (84.0% reduction, p < 0.0001), and from 1.3 ± 0.9 to 0.1 ± 0.3 medications in iStent inject eyes (94.7% reduction, p < 0.0001). Significantly more iStent inject eyes were medication-free at 12 months than iStent eyes (92.9% versus 76.1% medication-free, respectively; p = 0.0068). Favorable safety included few adverse events, no secondary glaucoma surgeries, and stable visual acuity and visual fields in both groups. CONCLUSION Significant and safe IOP and medication reductions were achieved through 12 months after iStent or iStent inject implantation with cataract surgery. iStent inject eyes had greater absolute IOP reduction and more eyes medication-free versus iStent eyes. FUNDING Glaukos Corporation.
Collapse
Affiliation(s)
- David Manning
- Hunter Cataract and Eye Centre, Charlestown, NSW, Australia.
| |
Collapse
|
14
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center. Adv Ther 2019; 36:2797-2810. [PMID: 31440981 PMCID: PMC6822971 DOI: 10.1007/s12325-019-01067-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Indexed: 11/20/2022]
Abstract
INTRODUCTION This retrospective consecutive case series assessed 12-month effectiveness and safety of iStent® or iStent inject® trabecular micro-bypass implants with cataract surgery in patients with open-angle glaucoma (OAG) in a real-world clinical setting. METHODS Effectiveness outcomes consisted of intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving IOP < 18, < 15, or < 12 mmHg; and proportional analysis of medication usage. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS This evaluation included 58 eyes with OAG (35 iStent, 23 iStent inject), with 96.6% of eyes having mild or moderate glaucoma. Diagnoses included primary open-angle glaucoma (the majority; 72.4%), pseudoexfoliative glaucoma, and pigmentary glaucoma. Baseline mean IOP and medications were statistically comparable between groups: 16.1 ± 3.6 mmHg on a mean of 1.8 ± 0.8 medications in the iStent group, and 16.2 ± 3.1 mmHg on a mean of 1.7 ± 0.8 medications in the iStent inject group. Twelve months after stent-cataract surgery, mean IOP was significantly lower in the iStent inject group than in the iStent group (13.1 mmHg vs. 15.4 mmHg, respectively; p < 0.001), and the percent reduction in IOP from baseline was significantly greater in iStent inject eyes than in iStent eyes (19.1% vs. 4.3% reduction, respectively; p < 0.001). At 12 months postoperative, significantly greater proportions of iStent inject eyes than iStent eyes achieved IOP < 18 mmHg (100% vs. 80.0% of eyes, respectively; p = 0.035), IOP < 15 mmHg (73.9% vs. 34.3% of eyes, respectively; p = 0.003), and IOP < 12 mmHg (26.1% vs. 0% of eyes, respectively; p = 0.002). Meanwhile, both groups achieved significant medication reductions at 12 months vs. baseline (94.1% reduction in iStent inject eyes, p < 0.0001; and 72.2% reduction in iStent eyes, p < 0.0001), with the percent reduction being significantly greater in iStent inject eyes than in iStent eyes (p = 0.023). At 12 months, mean number of medications was significantly lower in iStent inject eyes than iStent eyes (0.1 vs. 0.5 medications, respectively; p = 0.021), and significantly more iStent inject eyes (95.7%) than iStent eyes (71.4%) were off medications entirely (p = 0.021). A similarly high safety profile was observed in both groups. CONCLUSION iStent or iStent inject implantation with cataract surgery resulted in substantial and safe reductions in IOP and medications through 12 months postoperative. Consistent with prior observations, greater efficacy was observed with iStent inject than with iStent. FUNDING The Rapid Service Fees were funded by Glaukos Corporation.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Minas Gerais, Brazil.
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
| | | | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| |
Collapse
|
15
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Second-Generation Trabecular Micro-Bypass Stents as Standalone Treatment for Glaucoma: A 36-Month Prospective Study. Adv Ther 2019; 36:1606-1617. [PMID: 31119690 PMCID: PMC6824385 DOI: 10.1007/s12325-019-00984-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Indexed: 11/13/2022]
Abstract
INTRODUCTION To evaluate long-term outcomes following stand-alone implantation of two second-generation trabecular micro-bypass stents (iStent inject®, Glaukos Corp., San Clemente, CA, USA) in eyes with predominantly primary open-angle glaucoma (POAG) and considerable preoperative disease burden. METHODS Eyes with POAG, pseudoexfoliative glaucoma (PXG), appositional narrow-angle glaucoma (NAG, with open-angle configuration in the area of implantation), or secondary glaucoma were included in this prospective, non-randomized, consecutive case series. All eyes underwent ab interno iStent inject implantation as a sole procedure. Assessments through 36 months included IOP, medications, corrected distance visual acuity (CDVA), secondary glaucoma surgeries, and complications and adverse events. RESULTS Two iStent inject stents were implanted in 44 consecutive eyes (POAG = 38, PXG = 4, appositional NAG = 1, secondary neovascular glaucoma = 1) of 31 patients, and 33 eyes had 36-month follow-up data. Preoperative mean IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% of eyes on 3-5 medications, no eyes medication-free, and 50% of eyes with history of prior glaucoma surgery. At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) and 87.9% of eyes achieved an IOP reduction of ≥ 20% versus preoperatively. In addition, 97% of eyes reached IOP ≤ 18 mmHg (vs. 9.1% preoperatively; p < 0.0001) and 70.0% of eyes reached IOP ≤ 15 mmHg (vs. 2.3% preoperatively; p < 0.0001). Mean medication burden decreased by 82% to 0.55 ± 0.79 (p < 0.0001), and 61% of eyes became medication-free. All eyes maintained or decreased their 36-month medication burden versus preoperatively. Safety was favorable, including minimal adverse events and stable CDVA through 36 months postoperatively. CONCLUSION This real-world cohort of glaucomatous eyes with substantial preoperative disease burden experienced significant, sustained, safe IOP and medication reductions through 36 months following stand-alone iStent inject implantation. FUNDING Article processing charges and writing assistance were provided by Glaukos Corp. (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
- Department of Ophthalmology, Buergerhospital, Frankfurt, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
16
|
Samuelson TW, Sarkisian SR, Lubeck DM, Stiles MC, Duh YJ, Romo EA, Giamporcaro JE, Hornbeak DM, Katz LJ, Bartlett W, Buznego C, Johnson S, D'Ambrosio FA, Dehning D, DuBiner H, Goyal R, Hughes B, Marquis RE, Noecker R, Tauber S, Perez BR, Roel L, Sarkisian S, Silverstein S, Day S, Solomon K, Tyson F, Vold S, Samuelson T, Simmons S, Stiles M, Nguyen QH, Bashford KP, Flowers B, Flynn WJ, Gira J, Okeke C, Reiss GR, Tyson SL, Parkhurst G, Linn J, Lubeck D, Solomon J, Singh IP, Johnson RD, Lin C, Kim JW, Crane CJ, Cotter F. Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract. Ophthalmology 2019; 126:811-821. [DOI: 10.1016/j.ophtha.2019.03.006] [Citation(s) in RCA: 94] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 03/04/2019] [Accepted: 03/04/2019] [Indexed: 10/27/2022] Open
|
17
|
Gallardo MJ, Supnet RA. Three-year outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic population with primary open-angle glaucoma. Clin Ophthalmol 2019; 13:869-879. [PMID: 31239633 PMCID: PMC6554518 DOI: 10.2147/opth.s189071] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 02/19/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: To present long-term, real-world outcomes after implanting one trabecular micro-bypass stent with cataract surgery for primary open-angle glaucoma (POAG) in a predominantly Hispanic patient population. Patients and methods: This retrospective, consecutive case series evaluated intraocular pressure (IOP), medications, and safety through 36 months after implanting one iStent® during phacoemulsification cataract surgery. Eyes were stratified into 2 subgroups classified by preoperative IOP and surgical goal. The Controlled Group had IOP <18 mmHg on ≥1 medications, and goal to reduce medications. The Uncontrolled Group had IOP ≥18 mmHg and/or maximum tolerated medication load, and goal to reduce IOP. Assessments included IOP, medications, visual fields (VF), retinal nerve fiber layer thickness (RNFL), adverse events, and secondary surgeries. Results: Of 168 total operated eyes, 87 eyes (49 Controlled, 38 Uncontrolled) completed 36 months of follow-up and comprise the Consistent Cohort in this report. At baseline, 79.6% (39/49) of Controlled eyes and 71.1% (27/38) of Uncontrolled eyes were from Hispanic patients. In the Controlled Group desiring medication reduction, mean medications were reduced by 77.3% (2.6 medications preoperatively vs 0.6 at 36 months; p<0.001. All Controlled eyes maintained or reduced medications versus preoperative; no eyes were on ≥3 medications (vs 61.2% preoperatively); and 58.3% were medication-free (vs 0% preoperatively). In the Uncontrolled Group desiring IOP reduction, mean IOP decreased by 31.2% (19.4 mmHg preoperatively vs 13.4 mmHg at 36 months; p<0.001), 91.7% of eyes achieved IOP ≤18 mmHg, 69.4% reached IOP ≤15 mmHg, and 77.8% decreased IOP ≥20% vs baseline. Uncontrolled eyes also experienced a 45.3% medication reduction (2.2 medications preoperatively vs 1.2 at 36 months; p<0.001). Favorable safety included no intraoperative complications, and stable VF and RNFL through 36 months. Conclusion: In this predominantly Hispanic patient cohort, significant IOP and medication reductions were sustained safely through 36 months after iStent implantation during cataract surgery.
Collapse
Affiliation(s)
- Mark J Gallardo
- El Paso Eye Surgeons, PA, El Paso, TX, USA.,Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | | |
Collapse
|
18
|
Fechtner RD, Voskanyan L, Vold SD, Tetz M, Auffarth G, Masood I, Au L, Khouri AS, Ahmed IIK, Saheb H. Five-Year, Prospective, Randomized, Multi-Surgeon Trial of Two Trabecular Bypass Stents versus Prostaglandin for Newly Diagnosed Open-Angle Glaucoma. Ophthalmol Glaucoma 2019; 2:156-166. [PMID: 32672584 DOI: 10.1016/j.ogla.2019.03.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 01/14/2019] [Accepted: 03/12/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate 5-year safety and efficacy of 2 trabecular micro-bypass stents versus prostaglandin as initial stand-alone treatment for newly diagnosed, treatment-naive primary open-angle glaucoma (POAG). DESIGN Prospective, randomized, controlled, multi-surgeon clinical trial. PARTICIPANTS Enrolled eyes (n = 101) were phakic and had a confirmed POAG diagnosis, normal angle anatomy, mean diurnal intraocular pressure (IOP) 21 to 40 mmHg, and vertical cup-to-disc (C:D) ratio ≤0.9. METHODS Eyes were randomized (1:1) to receive either 2 stents (iStent trabecular micro-bypass; Glaukos Corporation, San Clemente, CA) or once-daily topical travoprost. MAIN OUTCOME MEASURES The primary and secondary efficacy end points were the change from screening in mean diurnal IOP at months 12 and 24, respectively, without glaucoma surgery or add-on medication (any medication in stent eyes or a second medication in travoprost eyes). Two additional secondary end points were the proportion of eyes achieving treatment success at months 12 and 24, defined as IOP 6 to 18 mmHg without additional medication or glaucoma surgery. This report shows these efficacy measures through 60 months. Safety measures included best-corrected visual acuity, C:D ratio, visual field, pachymetry, complications, and adverse events. RESULTS Of 101 enrolled eyes (54 stent eyes, 47 travoprost eyes), 90 eyes (49 stent eyes, 41 travoprost eyes) completed 5-year follow-up. Five-year mean diurnal IOP was 16.5±1.2 mmHg in stent eyes (35.3% reduced vs. 25.5±2.5 mmHg preoperatively; P < 0.0001) and 16.3±1.9 mmHg in travoprost eyes (35.1% reduced vs. 25.1±4.6 mmHg preoperatively; P < 0.0001). During follow-up, add-on medication was initiated in 12 stent eyes (22.2% of the initial 54-eyes) and 18 travoprost eyes (38.3% of the initial 47-eyes). By 5 years, 17% (6/35) of stent eyes and 44% (14/32) of travoprost eyes needed add-on medication to control IOP (P = 0.017). Treatment success was achieved in 77% (27/35) of stent eyes and 53% (17/32) of travoprost eyes (P = 0.04). Both groups exhibited excellent safety. CONCLUSIONS This prospective randomized trial demonstrates 5-year effectiveness and safety of 2 trabecular bypass stents in patients with newly diagnosed, treatment-naive POAG, with comparably favorable outcomes as topical prostaglandin.
Collapse
Affiliation(s)
- Robert D Fechtner
- State University of New York Upstate Medical University, Syracuse, New York.
| | | | | | - Manfred Tetz
- Berlin Eye Research Institute and Augenklinik Spreebogen, Berlin, Germany
| | - Gerd Auffarth
- Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany
| | - Imran Masood
- Birmingham City Hospital, Birmingham, United Kingdom
| | - Leon Au
- Manchester Royal Eye Hospital, Manchester, United Kingdom
| | | | | | - Hady Saheb
- Mcgill University, Montreal, Quebec, Canada
| |
Collapse
|
19
|
Neuhann TH, Hornbeak DM, Neuhann RT, Giamporcaro JE. Long-term effectiveness and safety of trabecular microbypass stent implantation with cataract surgery in patients with glaucoma or ocular hypertension: Five-year outcomes. J Cataract Refract Surg 2019; 45:312-320. [DOI: 10.1016/j.jcrs.2018.10.029] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 08/13/2018] [Accepted: 10/01/2018] [Indexed: 11/28/2022]
|
20
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. Intermediate Results of iStent or iStent inject Implantation Combined with Cataract Surgery in a Real-World Setting: A Longitudinal Retrospective Study. Ophthalmol Ther 2019; 8:87-100. [PMID: 30721523 PMCID: PMC6393257 DOI: 10.1007/s40123-019-0166-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Indexed: 11/02/2022] Open
Abstract
INTRODUCTION In this real-world, retrospective, comparative study we evaluated 6-month performance and safety in consecutive eyes following implantation of the iStent® or iStent inject® trabecular micro-bypass device with concomitant cataract surgery. METHODS Performance outcomes included intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving an IOP of < 18, < 16, < 14, or < 12 mmHg; and proportions of eyes on 0, 1, 2, or ≥ 3 medications. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS A total of 73 eyes with open-angle glaucoma and cataract were included in the study; of these, 38 eyes were implanted with the iStent device and 35 were implanted with the iStent inject device. The two groups of patients had similar baseline characteristics, with the exception of mean age and medication burden (both higher in patients receiving the iStent inject device); over 90% of eyes in both groups had early glaucoma. At 6 months after surgery, mean IOP had fallen from 16.5 ± 3.9 to 13.9 ± 2.3 mmHg in eyes with the iStent implant (p < 0.001), and from 17.3 ± 3.0 to 12.7 ± 1.8 mmHg in those with the iStent inject implant (p < 0.001). This reduction was significantly greater in the iStent inject eyes than in the iStent eyes (26.6 vs. 15.8%) (p = 0.005). Significantly more eyes receiving the iStent inject device compared to the iStent device achieved an IOP of < 18 mmHg at 6 months post surgery (100 vs. 86.8%) (p = 0.033). Average medication usage was reduced from 1.8 to 0.4 medications in iStent eyes (p < 0.001) and from 2.3 to 0.4 medications in iStent inject eyes (p < 0.001). Over 70% of eyes in both groups became medication-free by 6 months post implantation. Adverse events in iStent eyes were mild and resulted in no sequelae; two iStent eyes underwent non-penetrating deep sclerectomy during follow-up. No complications or secondary surgeries were noted in iStent inject eyes. All eyes in both groups maintained or showed improved BCVA versus baseline. CONCLUSION Significant and safe IOP and medication reductions were observed after iStent or iStent inject implantation with concomitant cataract surgery. Trends toward greater effectiveness and fewer adverse events were observed with the iStent inject device compared with the iStent device. FUNDING Article processing charges were provided by Glaukos Corporation.
Collapse
Affiliation(s)
| | | | - Jonathan Clive Lake
- Cataract and Glaucoma Department, Brasilia Vision Hospital, Brasilia, DF, Brazil
| | | | | |
Collapse
|
21
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Prospective, Non-randomized, 36-Month Study of Second-Generation Trabecular Micro-Bypass Stents with Phacoemulsification in Eyes with Various Types of Glaucoma. Ophthalmol Ther 2018; 7:405-415. [PMID: 30430427 PMCID: PMC6258575 DOI: 10.1007/s40123-018-0152-8] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Indexed: 11/24/2022] Open
Abstract
Introduction The aim of this study was to assess 36-month outcomes after cataract surgery and implantation of two second-generation trabecular micro-bypass stents (iStent inject, Glaukos Corporation, San Clemente, CA, USA) into eyes with predominantly primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PEX). Methods This prospective, non-randomized, consecutive cohort study included eyes with POAG (n = 60), PEX (n = 15), appositional narrow-angle (n = 4), pigmentary (n = 1), or neovascular (secondary) (n = 1) glaucoma and cataract requiring surgery. All eyes (n = 81) underwent ab interno iStent inject implantation following cataract surgery. Effectiveness endpoints through 36 months included intraocular pressure (IOP), number of medications, and proportion of eyes with ≥ 20% IOP reduction, IOP ≤ 18 mmHg, and IOP ≤ 15 mmHg. Safety measures included corrected distance visual acuity (CDVA), adverse events, and secondary surgeries. Outcomes were evaluated for the overall cohort, and for the POAG and PEX subgroups. Results Preoperatively, 32.1% of eyes had undergone prior glaucoma surgery, 56% were on 3–4 medications, and 1 eye (1%) was medication-free. At 36 months postoperatively, mean IOP reduced by 37% (14.3 ± 1.7 mmHg versus 22.6 ± 6.2 mmHg preoperatively), and mean medication burden decreased by 68% (0.8 ± 0.9 versus 2.5 ± 1.1 medications preoperatively). IOP reduced by ≥ 20% in 78% of eyes; 100% of eyes reached IOP ≤ 18 mmHg and 71% reached ≤ 15 mmHg. Medication burden reduced considerably: 22 eyes (54%) were medication-free compared to 1 eye (1%) preoperatively; 1 eye (2%) required ≥ 3 medications compared to 45 eyes (56%) preoperatively; and 92.7% of eyes required reduced medications postoperatively. From 3 through 36 months, mean IOP remained ≤ 15.0 mmHg, and mean number of medications remained ≤ 0.9. Outcomes in the POAG and PEX subgroups included 33% and 32% lower IOP, and 68% and 64% fewer medications, respectively. iStent inject showed a favorable safety profile, including no intraoperative complications, minimal adverse events, and a stable CDVA. Conclusion This real-world cohort of eyes with various types of glaucoma and considerable disease burden exhibited durable and safe IOP and medication reductions through 36 months following iStent inject implantation with cataract surgery. Outcomes were similarly beneficial in eyes with POAG and PEX. Funding Article processing charges were funded by Glaukos Corporation (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
22
|
Shah S, Rana M, Pandey P, Masood I. Endoscopic Goniosynechialysis for Acute Angle Closure Glaucoma Following Descemet\'s Stripping Automated Endothelial Keratoplasty. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
23
|
Elbably A, Othman TM, Mousa A, Elridy M, Badawy W, Elbably M. Deep Sclerectomy with Porous Collagen in Open-angle Glaucoma, Short-term Study. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1249] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
24
|
Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018; 12:67-84. [PMID: 30473602 PMCID: PMC6236117 DOI: 10.5005/jp-journals-10008-1248] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2018] [Accepted: 07/27/2018] [Indexed: 11/23/2022] Open
Abstract
Aim This meta-analysis explores the efficacy and adverse event profile of the iStent, an ab interno implant for the treatment of open-angle glaucoma. Methods A systematic literature search of Ovid MEDLINE and EMBASE was used to identify peer-reviewed original studies that provided efficacy data on the first or second generation iStent for at least five eyes. Intraocular pressure (IOP) was the primary efficacy endpoint, while the number of medication classes was the secondary outcome. Weighted mean differences were reported for continuous endpoints, while a relative risk was computed for dichotomous variables. Review Results The search revealed 545 results, of which 1767 eyes from 28 studies were included. The cohort age was 71.4 ± 5.4 years, and 44.9% of patients were male. There was a significantly greater IOP reduction after the use of two first-generation stents compared to one, irrespective of phacoemulsification status (p < 0.001). Additionally, there was a significantly greater IOP reduction following iStent alone relative to phaco-iStent for the first-generation iStent (p < 0.001) and the iStent inject (p < 0.001). For the first generation stent, combined phaco-iStent provided a greater level of IOP reduction (p < 0.001) and reduction in the number of medication classes relative to phacoemulsification alone (p < 0.001). In total, 22.5% of eyes that received iStent implantation sustained some type of adverse event. The most common adverse events were intraocular pressure elevation, stent blockage or obstruction, stent malposition and hyphema. Conclusion and Clinical Significance Statistically significant differences in efficacy outcomes exist between different numbers of stents and the presence or absence of concurrent phacoemulsification. How to cite this article: Popovic M, Campos-Moller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018;12(2):67-84.
Collapse
Affiliation(s)
- Marko Popovic
- Research Assistant, Faculty of Medicine, University of Toronto, Toronto, Canada
| | - Xavier Campos-Moller
- Ophthalmologist, Western Health Eye Care Centre, Corner Brook, Newfoundland, Canada
| | - Hady Saheb
- Ophthalmologist, Department of Ophthalmology, McGill University, Montreal, Quebec, Canada
| | - Iqbal Ike K Ahmed
- Ophthalmologist, Department of Ophthalmology and Vision Sciences, University of Toronto, Mississauga, Ontario, Canada
| |
Collapse
|
25
|
Myers JS, Masood I, Hornbeak DM, Belda JI, Auffarth G, Jünemann A, Giamporcaro JE, Martinez-de-la-Casa JM, Ahmed IIK, Voskanyan L, Katz LJ. Prospective Evaluation of Two iStent ® Trabecular Stents, One iStent Supra ® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes. Adv Ther 2018; 35:395-407. [PMID: 29476443 PMCID: PMC5859115 DOI: 10.1007/s12325-018-0666-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Indexed: 12/01/2022]
Abstract
Introduction This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Methods Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1–3 glaucoma medications. Subjects received two iStent® trabecular micro-bypass stents, one iStent Supra® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Results Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. Conclusion IOP control was achieved safely with two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin. This microinvasive, ab interno approach introduces a possible new treatment option for refractory disease. Trial Registration NCT01456390. Funding Glaukos Corporation. Electronic supplementary material The online version of this article (10.1007/s12325-018-0666-4) contains supplementary material, which is available to authorized users.
Collapse
|
26
|
Katz LJ, Erb C, Carceller Guillamet A, Fea AM, Voskanyan L, Giamporcaro JE, Hornbeak DM. Long-term titrated IOP control with one, two, or three trabecular micro-bypass stents in open-angle glaucoma subjects on topical hypotensive medication: 42-month outcomes. Clin Ophthalmol 2018; 12:255-262. [PMID: 29440867 PMCID: PMC5798569 DOI: 10.2147/opth.s152268] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Evaluate long-term outcomes after one, two, or three trabecular micro-bypass stents implanted in a standalone procedure in eyes with open-angle glaucoma taking ocular hypotensive medication. Patients and methods Prospective randomized ongoing study of 119 subjects (109 with 42-month follow-up) with open-angle glaucoma, preoperative intraocular pressure (IOP) 18-30 mmHg on one to three glaucoma medications, and unmedicated (post-washout) IOP 22-38 mmHg. Subjects were randomized to receive one (n=38), two (n=41), or three (n=40) iStent trabecular micro-bypass stents in a standalone procedure. Postoperatively, IOP was measured with medication and annually following washout. Data included IOP, medications, gonioscopy, pachymetry, visual field, visual acuity, adverse events, and slit-lamp and fundus examinations. Results Preoperative mean medicated IOP was 19.8±1.3 mmHg on 1.71 medications in one-stent eyes, 20.1±1.6 mmHg on 1.76 medications in two-stent eyes, and 20.4±1.8 mmHg on 1.53 medications in three-stent eyes. Post-washout IOP prior to stent implantation was 25.0±1.2, 25.0±1.7, and 25.1±1.9 mmHg in the three groups, respectively. Postoperatively, Month 42 medicated IOP was 15.0±2.8, 15.7±1.0 and 14.8±1.3 mmHg in the three groups, and post-washout IOP (Months 36-37) was 17.4±0.9, 15.8±1.1 and 14.2±1.5 mmHg, respectively. IOP reduction ≥20% without medication was achieved in 89%, 90%, and 92% of one-, two-, and three-stent eyes, respectively, at Month 12; and in 61%, 91%, and 91% of eyes, respectively, at Month 42. The need for additional medication remained consistent at Months 12 and 42 in multi-stent eyes (four two-stent eyes and three three-stent eyes at both time points), whereas it increased in single-stent eyes (four eyes at Month 12 versus 18 eyes at Month 42). Safety parameters were favorable in all groups. Conclusion The standalone implantation of either single or multiple iStent® device(s) produced safe, clinically meaningful IOP and medication reductions through 42 months postoperatively, with incrementally greater and more sustained reductions in multi-stent eyes.
Collapse
Affiliation(s)
- L Jay Katz
- Glaucoma Service, Wills Eye Hospital, Philadelphia, PA, USA
| | - Carl Erb
- Glaucoma Service, Eye Clinic Wittenbergplatz, Berlin, Germany
| | | | - Antonio M Fea
- Department of Surgical Sciences, University of Torino, Torino, Italy
| | - Lilit Voskanyan
- Glaucoma Service, S. V. Malayan Ophthalmology Centre, Yerevan, Armenia
| | - Jane Ellen Giamporcaro
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| | - Dana M Hornbeak
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| |
Collapse
|
27
|
Singh K, Mutreja A, Bhattacharyya M, Dangda S, Jaisingh K. Bilateral Phacomatosis Pigmentovascularis in a Young Male with Developmental Glaucoma and Varicose Veins. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
28
|
Popovic M, Campos-Möller X, Saheb H, Ahmed IIK. Efficacy and Adverse Event Profile of the iStent and iStent Inject Trabecular Micro-bypass for Open-angle Glaucoma: A Meta-analysis. J Curr Glaucoma Pract 2018. [DOI: 10.5005/jp-journals-10028-1248] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|