1
|
Gillmann K, Hornbeak DM. Rates of visual field change and functional progression in glaucoma following trabecular microbypass implantation of iStent technologies: a meta-analysis. BMJ Open Ophthalmol 2024; 9:e001575. [PMID: 38360043 PMCID: PMC10875546 DOI: 10.1136/bmjophth-2023-001575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 01/30/2024] [Indexed: 02/17/2024] Open
Abstract
BACKGROUND/AIM While intraocular pressure (IOP) remains the only modifiable risk factor for glaucoma progression, the ultimate goal of glaucoma management is to preserve patients' functional vision and quality of life. To this end, minimally invasive glaucoma surgeries (MIGSs) aim to reduce IOP with minimal eye trauma. Commonly used MIGS devices include iStent technologies, which have well-documented IOP-reducing potential and favourable safety profiles. However, no study concluded on their effect on the rates of visual field (VF) changes. The aim of this meta-analysis is to determine the long-term effect of iStent technology implantation on glaucoma functional progression. METHODS Electronic medical literature databases were searched to identify studies reporting on iStent technologies. Reports with follow-up durations <12 months, retention rates <75% and missing VF data were excluded. Fifteen studies reporting on 1115 eyes were identified. The overall weighted mean VF mean deviation (MD) progression, IOP reduction and follow-up duration were calculated. RESULTS Weighted mean IOP at baseline was 19.0±3.1 mm Hg. At the end of a 37.9-month mean follow-up (range 12-96 months), a weighted mean 26.6% IOP reduction was achieved (range 15.2%-42.3%). Over the same duration, the weighted mean VF MD progression rate was -0.02±0.34 dBs/year, from a mean baseline of -5.76±5.68 dBs. CONCLUSION In this review, which examines functional stability of 1115 eyes, iStent technologies achieved a mean rate of progression of -0.024 dBs/year with serial standard automated perimetry, which is similar to that reported in non-glaucomatous eyes and slower than that reported in medically treated glaucoma.
Collapse
Affiliation(s)
- Kevin Gillmann
- Genève Ophtalmologie, Geneva, Switzerland
- Stanford University, Palo Alto, California, USA
| | | |
Collapse
|
2
|
Khalilova TA, Zaitseva AA, Koveshnikov AI. [Micro-invasive glaucoma surgery]. Vestn Oftalmol 2023; 139:90-95. [PMID: 37942602 DOI: 10.17116/oftalma202313905190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Glaucoma is a severe, rapidly progressing disease that in the absence of proper treatment leads to blindness in 20% of patients. According to the World Glaucoma Association, this disease is the most socially significant in modern ophthalmology and requires searching for new and effective methods of treatment. This article presents the results of research and reviews on this issue, considers both conservative therapy and surgical methods of treatment, analyzes in detail modern methods of micro-invasive eye surgery actively used in clinical practice. The article also describes indications for a various types of interventions, as well as the effect achieved by them and the possible complications, and presents the conclusions about the possibility of using these procedures in wide clinical practice.
Collapse
Affiliation(s)
- T A Khalilova
- S.N. Fedorov National Medical Research Center "MNTK "Eye microsurgery", Moscow, Russia
| | | | | |
Collapse
|
3
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
4
|
Salimi A, Watt H, Harasymowycz P. Long-term outcomes of two first-generation trabecular micro-bypass stents (iStent) with phacoemulsification in primary open-angle glaucoma: eight-year results. EYE AND VISION 2021; 8:43. [PMID: 34782017 PMCID: PMC8594216 DOI: 10.1186/s40662-021-00263-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2021] [Accepted: 10/11/2021] [Indexed: 02/06/2023]
Abstract
Background The short- and medium-term outcomes of iStent have been extensively studied; however, only few studies have investigated its long-term outcomes. Here, we assessed the long-term efficacy and safety of two iStents with concomitant cataract surgery in glaucomatous eyes while also evaluating measures of disease stability using visual field and optical coherence tomography (OCT) of the optic nerve and the macula throughout 8 years of follow-up. Methods This longitudinal, single-center consecutive case series included glaucomatous eyes that underwent implantation of two first-generation trabecular micro-bypass stents (iStent) with concomitant cataract surgery. Eight-year efficacy outcomes included mean intraocular pressure (IOP) and medications, as well as surgical success. Eight-year safety outcomes included best-corrected visual acuity (BCVA), visual field mean deviation (VF-MD), cup-to-disc ratio (CDR), retinal nerve fiber layer (RNFL) thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, and adverse events. Results A total of 62 eyes with primary open-angle glaucoma (POAG) were included. At 8 years postoperative, IOP reduced by 26% from 19.2 ± 3.9 mmHg preoperatively to 14.2 ± 2.4 mmHg (P < 0.001), 91.1% of eyes achieved IOP ≤ 18 mmHg (vs. 51.6% preoperatively), 69.6% of eyes achieved IOP ≤ 15 mmHg (vs. 14.5% preoperatively), and 25% of eyes achieved IOP ≤ 12 mmHg (vs. 1.6% preoperatively). Medication use decreased by 17.9% from 2.8 ± 1.1 preoperatively to 2.3 ± 1.2 (P = 0.018). Surgical success was 90%, as six eyes underwent subsequent glaucoma surgeries. Safety measures of BCVA, CDR, RNFL thickness and GC-IPL thickness remained stable through 8 years postoperative. VF-MD remained stable until postoperative year 5 and subsequently progressed according to the natural history of glaucomatous disease. Conclusions Implantation of two iStents with concomitant cataract surgery is an effective and safe treatment option for surgery-naïve POAG eyes, evidenced by significant IOP and medication reductions, reasonable surgical success, and favorable safety outcomes, throughout the 8-year follow-up. Our data additionally supports the efficacy of this combined procedure in stabilizing or slowing disease progression. Supplementary Information The online version contains supplementary material available at 10.1186/s40662-021-00263-1.
Collapse
Affiliation(s)
- Ali Salimi
- Department of Ophthalmology, Faculty of Medicine, McGill University, Montreal, QC, Canada.,Montreal Glaucoma Institute, Montreal, QC, Canada
| | - Harrison Watt
- Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Paul Harasymowycz
- Montreal Glaucoma Institute, Montreal, QC, Canada. .,Department of Ophthalmology, University of Montreal, 4135 de Rouen, Montreal, QC, H1V1G5, Canada.
| |
Collapse
|
5
|
Salimi A, Abu-Nada M, Harasymowycz P. Matched Cohort Study of Cataract Surgery With and Without Trabecular Microbypass Stent Implantation in Primary Angle-Closure Glaucoma. Am J Ophthalmol 2021; 224:310-320. [PMID: 33428885 DOI: 10.1016/j.ajo.2020.12.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 12/28/2020] [Accepted: 12/28/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To compare 1-year outcomes of phacoemulsification alone (phaco-only) vs phacoemulsification with implantation of 2 trabecular microbypass stents (iStent or iStent inject; phaco-stent) in eyes with primary angle-closure glaucoma (PACG). DESIGN Retrospective matched clinical cohort study. METHODS PACG eyes that underwent phaco-only vs phaco-stent at a single ophthalmology center. Groups were matched for baseline intraocular pressure (IOP) and medication use with a tolerance of ±2 mm Hg and ±1 medication, respectively. Primary outcomes included postoperative change in the mean IOP and medications. One-year outcomes were assessed using generalized estimating equations corrected for baseline intergroup differences. RESULTS One hundred fifty-eight eyes (79 per group) were included. At 1 year, IOP decreased by 13% (from 16.8 ± 3.1 mm Hg preoperatively) in the phaco-only group (P < .001) and by 27% (from 17.6 ± 3.2 mm Hg) in the phaco-stent group (P < .001). Medication use decreased by 11% (from 1.8 ± 1.3 medications preoperatively) in the phaco-only group (P < .001) and by 46% (from 2.2 ± 1.2 medications) in the phaco-stent group (P < .001). The phaco-stent group experienced significantly larger reductions in IOP and medications compared with the phaco-only group (P < .001). The incidence of IOP spikes was significantly greater in the phaco-only group (18%) compared with the phaco-stent group (4%; P = .005). Safety was favorable with few transient postoperative adverse events. CONCLUSION The results of this study highlight that phacoemulsification with implantation of 2 trabecular microbypass stents is more effective and possibly more protective than phaco-only in PACG eyes, as evidenced by significantly larger IOP and medication reductions and smaller incidences of IOP spikes among the phaco-stent eyes.
Collapse
|
6
|
Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis. J Glaucoma 2021; 30:606-620. [PMID: 33596009 DOI: 10.1097/ijg.0000000000001805] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 01/07/2021] [Indexed: 11/25/2022]
Abstract
PRECIS Standalone trabecular micro-bypass glaucoma surgery with the iStent devices is associated with clinically relevant reductions in intraocular pressure (IOP) sustained over a reasonably long-term while simultaneously reducing medication burden and a relatively favorable safety profile. PURPOSE While there is a relatively large body of evidence supporting the implantation of the iStent trabecular micro-bypass devices during phacoemulsification in patients with open-angle glaucoma (OAG), its efficacy as a standalone procedure has been less widely reported. The aims of this study were to systematically identify and quantitatively evaluate the efficacy of iStent devices (iStent and iStent inject) when performed independently of cataract surgery in patients with OAG. METHODS A systematic review of the literature was undertaken in August 2019 to identify studies of standalone trabecular micro-bypass glaucoma surgery with iStent devices in patients with OAG. All randomized trials were considered and nonrandomized studies that included at least 6 months of follow-up or more than 10 eyes. Key efficacy analyses included postoperative IOP and medication use, which were used to evaluate weighted mean differences from baseline, and the proportion of eyes free of ocular medication. Postoperative adverse events were descriptively summarized. RESULTS A total of 13 studies were identified including 4 randomized controlled trials and 9 nonrandomized or single-arm studies providing data for 778 eyes. In eyes implanted with iStent devices, a weighted mean IOP reduction of 31.1% was observed at 6 to 12 months. In studies reporting longer-term outcomes (36 to 48 mo or 60 mo), the weighted mean IOP reduction was 30.4% and 32.9%, respectively. The pooled weighted mean reduction in IOP from baseline across all studies at 6 to 12 months and 36 to 60 months poststent implantation was 7.01 mm Hg (95% confidence interval: 5.91, 8.11) and 6.59 mm Hg (95% confidence interval: 5.55, 7.63), respectively. Medication burden was reduced by ~1.0 medication at 6 to 18 months and 1.2 medications at 36 to 60 months. Adverse events reported in more than 5% of participants were progression of pre-existing cataract/cataract surgery and loss of best-corrected visual acuity but these rates were no different to those reported in comparator medical therapy study arms. CONCLUSIONS The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.
Collapse
|
7
|
Clement C, Howes F, Ioannidis AS, Shiu M, Manning D, Lusthaus J, Lim R, Skalicky SE, Goodwin T. Two-Year Multicenter Outcomes of iStent inject Trabecular Micro-Bypass Stents Combined with Phacoemulsification in Various Types of Glaucoma and Ocular Hypertension. Clin Ophthalmol 2020; 14:3507-3517. [PMID: 33149544 PMCID: PMC7604539 DOI: 10.2147/opth.s271646] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Accepted: 10/15/2020] [Indexed: 12/11/2022] Open
Abstract
Purpose This multicenter study evaluated 2-year effectiveness and safety following implantation of two second-generation trabecular micro-bypass stents (iStent inject®) with phacoemulsification. Materials and Methods This was a retrospective study of iStent inject implantation with phacoemulsification by nine surgeons across Australia. Eyes had mild to advanced glaucoma (predominantly primary open-angle/POAG, appositional angle-closure/ACG, or normal-tension/NTG) or ocular hypertension (OHT), and cataract. Evaluations included intraocular pressure (IOP); medications; proportions of eyes with 0 or ≥2 medications, reduced/stable medications versus preoperative, and IOP ≤15 mmHg; visual acuity; cup-to-disc ratio (CDR); visual fields (VF); adverse events; and secondary surgery. Results A total of 340 eyes underwent surgery and had 24-month follow-up data. At 24 months, mean IOP decreased by 16% from 16.4±4.7 mmHg preoperatively to 13.7±3.1 mmHg (p<0.001), and 77% of eyes achieved IOP of ≤15 mmHg versus 49% preoperatively (p<0.001). Mean number of medications decreased by 67% to 0.49±0.95 versus 1.49±1.20 preoperatively (p<0.001), with 74% of eyes medication-free versus 25% preoperatively (p<0.001), and 14% of eyes on ≥2 medications versus 46% preoperatively (p<0.001). Medication burden was reduced or stable in 98% of eyes versus preoperative. Stratified analyses showed significant IOP and medication reductions across glaucoma subtypes (POAG, ACG, NTG, OHT): 13–22% for IOP (p<0.01 for all) and 62–100% for medication (p<0.001 for all). Favorable safety included few adverse events; stable CDR, VF, and visual acuity; and filtering surgery in only 8 eyes (2.4%) over 2 years. Conclusion This 340-eye multicenter dataset provides robust evidence of the safety and efficacy of iStent inject implantation with phacoemulsification, with significant and sustained IOP and medication reductions through 2 years. Results were similarly favorable across glaucoma subtypes (including POAG, ACG, NTG, OHT) and were attained across various glaucoma severities, clinical sites, and surgeons, highlighting the real-world versatility and utility of this treatment modality.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia.,Fairfield Eye Surgery, Fairfield, NSW, Australia.,Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia.,Eyehaus, Sydney, NSW, Australia
| | - Ridia Lim
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia.,Hunter St. Eye Specialists, Parramatta, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
8
|
Nitta K, Yamada Y, Morokado S, Sugiyama K. iStent Trabecular Micro-Bypass Stent Implantation with Cataract Surgery in a Japanese Glaucoma Population. Clin Ophthalmol 2020; 14:3381-3391. [PMID: 33116389 PMCID: PMC7574908 DOI: 10.2147/opth.s274281] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 09/28/2020] [Indexed: 01/18/2023] Open
Abstract
Introduction This study assesses two-year efficacy and safety following implantation of a single trabecular micro-bypass stent (iStent®) with concomitant phacoemulsification cataract surgery in Japanese patients with open-angle glaucoma (OAG). Materials and Methods This retrospective, consecutive case series included eyes that underwent iStent implantation with phacoemulsification and were followed for 24 months postoperative. Efficacy and safety measures included intraocular pressure (IOP), number of glaucoma medications, adverse events, secondary surgeries, visual fields, and endothelial cell counts. Results Of 73 operated eyes, 53 eyes had 24 months of follow-up and are analyzed. Diagnoses included primary open-angle glaucoma (POAG, n=25), normal-tension glaucoma (NTG, n=16), and pseudoexfoliative glaucoma (PXG, n=12). At 24 months, mean IOP reduced by 18% to 13.6±3.0 mmHg versus 16.5±3.4 mmHg preoperatively (p<0.0001), and mean medication number reduced by 81% to 0.37±0.74 versus 1.96±0.98 preoperatively (p<0.0001). The percentage of medication-free eyes was 77% versus 0% preoperatively, and 81% of eyes had IOP ≤15 mmHg versus 42% preoperatively. Results were similarly favorable across glaucoma subtypes (POAG, NTG, PXG). Notably, mean IOP in NTG eyes decreased to 12.8±1.4 mmHg from 14.4±3.0 mmHg preoperatively (p=0.03), and medications decreased by 87% to 0.31±0.70 versus 2.38±0.72 preoperatively (p<0.0001). At 24 months, 81% of NTG eyes were medication-free (versus 0% preoperatively); 2 NTG eyes (13%) were on ≥2 medications (versus 100% preoperatively). Throughout the follow-up, visual fields and endothelial cell counts remained stable; 1 eye (1.9%) underwent filtration surgery. Discussion Favorable safety and significant IOP and mediation reductions were achieved through two years following iStent implantation with phacoemulsification in a Japanese population. These gains were achieved across all glaucoma subtypes (including POAG, NTG, PXG). Conclusion This real-world study supports the viability of iStent implantation to treat Japanese patients with glaucoma and shows that the benefits extend to those with NTG or PXG in addition to POAG.
Collapse
Affiliation(s)
- Koji Nitta
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Yutaro Yamada
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Satomi Morokado
- Department of Ophthalmology, Fukui-Ken Saiseikai Hospital, Fukui, Fukui Prefecture, Japan
| | - Kazuhisa Sugiyama
- Department of Ophthalmology, Kanazawa University, Kanazawa, Ishikawa Prefecture, Japan
| |
Collapse
|
9
|
Denis P, Hirneiß C, Durr GM, Reddy KP, Kamarthy A, Calvo E, Hussain Z, Ahmed IK. Two-year outcomes of the MINIject drainage system for uncontrolled glaucoma from the STAR-I first-in-human trial. Br J Ophthalmol 2020; 106:65-70. [PMID: 33011690 PMCID: PMC8685654 DOI: 10.1136/bjophthalmol-2020-316888] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/07/2020] [Accepted: 09/16/2020] [Indexed: 11/15/2022]
Abstract
Background/Aims The current study evaluates the efficacy and safety of the stand-alone implantation of the MINIject (iSTAR Medical, Wavre, Belgium) supraciliary, microinvasive glaucoma drainage device in patients with medically uncontrolled open-angle glaucoma. Methods This prospective, multicentre, first-in-human, single-arm interventional study evaluated stand-alone, ab interno implantation in 25 patients of a 5 mm long uveoscleral device made of STAR biocompatible material, which is a soft, microporous, flexible silicone. The primary outcome was the reduction of intraocular pressure (IOP) at 6 months compared with baseline, and follow-up continued until 2 years for 21 patients. Secondary outcomes included success defined as diurnal IOP of ≤21 mmHg and >5 mmHg with an IOP reduction of 20% without (complete) or with/without (qualified) glaucoma medication. Results Mean baseline IOP was 23.2±2.9 mmHg on 2.0±1.1 glaucoma medication ingredients and decreased to 13.8±3.5 mmHg (−40.7% reduction) on 1.0±1.3 medications 2 years after implantation. Complete success was achieved in 47.6% of patients (10/21) and qualified success in 100% of patients (21/21) at the 2-year follow-up. All patients achieved a 20% IOP reduction with 48% of patients medication-free. No serious ocular adverse events or additional glaucoma surgery were reported. Mean central endothelial cell density (ECD) mildly decreased from 2411 cells/mm2 (n=26) to 2341 cells/mm2 (n=21) at 24 months, which represents a 5% decrease for matched eyes. No patient had a ≥30% decrease in central ECD. Conclusion This first-in-human study on the stand-alone implantation of the MINIject supraciliary drainage system shows promising IOP-lowering results and medication reduction over 24 months with few adverse events. Trial registration number NCT03193736.
Collapse
Affiliation(s)
| | - Christoph Hirneiß
- Klinikum der Universität München, Ludwig-Maximilians-Universität, Munich, Germany
| | - Georges M Durr
- Centre Hospitalier Universitaire de Montréal (CHUM), Montreal, Canada
| | | | - Anita Kamarthy
- Maxivision Super Speciality Eye Hospital, Hyderabad, India
| | - Ernesto Calvo
- Panama Eye Center (previously Clínica de Ojos Orillac-Calvo), Panama City, Panama
| | | | - Iqbal K Ahmed
- Ophthalmology and Vision Sciences, University of Toronto, Toronto, Canada
| |
Collapse
|
10
|
Saheb H, Donnenfeld ED, Solomon KD, Voskanyan L, Chang DF, Samuelson TW, Ahmed IIK, Katz LJ. Five-Year Outcomes Prospective Study of Two First-Generation Trabecular Micro-Bypass Stents (iStent®) in Open-Angle Glaucoma. Curr Eye Res 2020; 46:224-231. [PMID: 32715828 DOI: 10.1080/02713683.2020.1795881] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
PURPOSE To assess 5-year effectiveness and safety of 2 iStent® trabecular micro-bypass stents in eyes with open-angle glaucoma (OAG) not controlled on 1 medication. MATERIALS AND METHODS This prospective, interventional, single-arm, multi-surgeon study (NCT #1252862, clinicaltrials.gov) enrolled eyes with OAG, preoperative intraocular pressure (IOP) of 18-30 mmHg on 1 ocular hypotensive medication, and 22-38 mmHg after medication washout. Eyes underwent standalone implantation of 2 iStent devices and were followed through 60 months postoperatively. Efficacy was quantified by mean diurnal IOP and medication usage. Efficacy endpoints included the proportion of eyes with ≥20% IOP reduction versus baseline unmedicated IOP (primary efficacy), and the proportion of eyes with IOP ≤18 mmHg (secondary efficacy) without medication or secondary glaucoma surgery. Safety parameters included visual acuity, cup-to-disc ratio, visual field, and complications and adverse events. RESULTS Preoperative mean IOP on 1 medication was 20.6 ± 2.0 mmHg and post-washout unmedicated IOP was 24.1 ± 1.4 mmHg (n = 39). At 5 years postoperative, medication-free mean diurnal IOP reduced to 14.5 ± 2.2 mmHg, constituting a 40% decrease versus preoperative washed-out IOP (p < .0001). In addition, this 5-year medication-free IOP constituted a 30% decrease versus preoperative IOP on 1 medication (p < .0001). At Month 60, 89.7% (26/29) of eyes achieved the primary efficacy endpoint of ≥20% IOP reduction versus baseline unmedicated IOP, and 86.2% (25/29) of eyes achieved the secondary efficacy endpoint of IOP ≤18 mmHg, without medication or secondary glaucoma surgery. Throughout follow-up, 89.7-91.3% of eyes were on no medications. Favorable safety included no secondary glaucoma surgeries, minimal adverse events, and stable visual acuity, cup-to-disc ratio, and visual fields through 5 years postoperative. CONCLUSIONS This prospective interventional study demonstrates persistent 5-year reductions in IOP and freedom from medications, together with favorable safety, following implantation of 2 first-generation trabecular micro-bypass stents in eyes with OAG on 1 preoperative medication.
Collapse
Affiliation(s)
- Hady Saheb
- Department of Ophthalmology, McGill University , Montreal, Quebec, Canada
| | - Eric D Donnenfeld
- Ophthalmic Consultants of Long Island , Rockville Centre, New York, USA
| | - Kerry D Solomon
- Carolina Eyecare Physicians , Mt Pleasant, South Carolina, USA
| | | | | | | | - Iqbal Ike K Ahmed
- Department of Ophthalmology, University of Toronto , Toronto, Ontario, Canada
| | - L Jay Katz
- Department of Ophthalmology, Wills Eye Hospital, Jefferson Medical College , Philadelphia, Pennsylvania, USA
| |
Collapse
|
11
|
Al Habash A, Khan O. Outcomes of Combined iStent Trabecular Micro-Bypass and Cataract Surgery for the Treatment of Open-Angle Glaucoma in a Saudi Population. Clin Ophthalmol 2020; 14:1573-1580. [PMID: 32606572 PMCID: PMC7295541 DOI: 10.2147/opth.s249261] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Accepted: 04/02/2020] [Indexed: 11/27/2022] Open
Abstract
Purpose To assess the effectiveness and safety of a single iStent trabecular micro-bypass stent implantation in combination with cataract surgery in lowering the intra ocular pressure (IOP) and number of anti-glaucoma medications in Saudi patients with open-angle glaucoma (OAG). Setting King Fahad Hospital of the University, Al Khobar, Saudi Arabia. Design Prospective, non-comparative, uncontrolled, non-randomized interventional case series. Methods One iStent was implanted during phacoemulsification cataract surgery for adult patients with OAG by a single surgeon over a period of 3 years. Main outcome measures include number of anti-glaucoma medications, IOP, corrected distance visual acuity (CDVA) and complications. Results Thirty-six eyes of 33 patients with OAG underwent the surgery. The pre-operative mean IOP and mean anti-glaucoma medications were 17.47 ± 5.44 mmHg and 2.69 ± 0.92, respectively. At 1 year of follow-up mean, IOP decreased to 13.44 ± 1.99 (23.1% reduction) (P<0.001) and mean anti-glaucoma medications decreased to 1.47±1.13 (45.4% reduction) (P<0.001). Conclusion After 12-month follow-up, phacoemulsification with the implantation of a single iStent seems to be an effective and safe procedure to lower IOP and the number of anti-glaucoma medications, and to overcome the problems associated with medication nonadherence in OAG patients with cataracts.
Collapse
Affiliation(s)
- Ahmed Al Habash
- Department of Ophthalmology, College of Medicine, King Fahd Hospital of the University, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Omar Khan
- Ministry of Health, Madinah, Saudi Arabia
| |
Collapse
|
12
|
Use of iStent as a Standalone Operation in Patients with Open-Angle Glaucoma. J Ophthalmol 2020; 2020:8754730. [PMID: 32566270 PMCID: PMC7267876 DOI: 10.1155/2020/8754730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2019] [Revised: 05/03/2020] [Accepted: 05/12/2020] [Indexed: 12/04/2022] Open
Abstract
Purpose The iStent provides a direct pathway for aqueous outflow from the anterior chamber to Schlemm's canal in patients with open-angle glaucoma (OAG). We performed a meta-analysis to evaluate the effectiveness of iStent as a standalone operation in patients with OAG in reducing the intraocular pressure (IOP) and the number of topical glaucoma medications. Methods We searched various databases between January 1, 2000, and September 30, 2019, and included only peer-reviewed, prospective, or retrospective clinical studies in our analyses. Details regarding the IOP and the number of medications at baseline and end point were recorded from each study. Standardized mean differences (SMDs) of IOP and medication numbers were calculated. Furthermore, the success rate (the proportion of IOP ≤18 mmHg and IOP reduction ≥20% at end point) and the complication rate were also summarized. Finally, a subgroup analysis was done based on the iStent generation (first and second), follow-up duration (≤6, 6–18, 18–36, and >36 months), and iStent number (one, two, and three). The outcome measures were aggregated SMDs computed from each study. Results A total of 17 studies with 978 eyes were included in this analysis. All studies demonstrated a reduction in IOP after iStent implantation. Aggregated SMDs of IOP revealed a significant reduction (SMD = −2.64, 95% confidence interval (CI): −3.21 to −2.07). The success rate was significantly good, and most of the complication rates were low. The number of medications was also significantly reduced (SMD = −1.71, 95% CI: −2.18 to −1.24). The subgroup analysis revealed a reduction in IOP and medication burden in each category of iStent generation, follow-up duration of up to 42 months, and iStent numbers. Conclusion Use of iStent as a standalone procedure does reduce the IOP and the number of glaucoma medications. The benefit of iStent lasts for at least 42 months.
Collapse
|
13
|
Berdahl J, Voskanyan L, Myers JS, Katz LJ, Samuelson TW. iStent
inject trabecular micro‐bypass stents with topical prostaglandin as standalone treatment for open‐angle glaucoma: 4‐year outcomes. Clin Exp Ophthalmol 2020; 48:767-774. [DOI: 10.1111/ceo.13763] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 04/01/2020] [Accepted: 04/09/2020] [Indexed: 01/22/2023]
Affiliation(s)
- John Berdahl
- Vance Thompson Vision Sioux Falls South Dakota USA
| | | | - Jonathan S. Myers
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
| | - L. Jay Katz
- Wills Eye HospitalJefferson Medical College Philadelphia Pennsylvania USA
- Glaukos Corporation San Clemente California USA
| | | |
Collapse
|
14
|
Rosdahl JA, Gupta D. Prospective Studies of Minimally Invasive Glaucoma Surgeries: Systematic Review and Quality Assessment. Clin Ophthalmol 2020; 14:231-243. [PMID: 32158182 PMCID: PMC6986542 DOI: 10.2147/opth.s239772] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Accepted: 12/24/2019] [Indexed: 12/05/2022] Open
Abstract
Glaucoma is a common blinding disease; while there is no cure, effective treatments include medications, laser, and incisional surgery. There is significant interest from patients and doctors to develop safer surgical options throughout the spectrum of disease, to minimize treatment burden in mild glaucoma patients and to minimize risk of complications in patients needing more aggressive treatment. Surgical procedures called Minimally or Micro-Invasive Glaucoma Surgery (MIGS) are growing in popularity. Eighty-seven prospective studies on MIGS were identified and assessed for quality. Most (74%) did not have a control group. Twelve of the highest quality were reviewed. MIGS procedures appeared to have fewer complications, and lowered intraocular pressure, and reduced medication use. Studies were limited by small sample size, narrow spectrum of glaucomatous disease, and/or conflicts of interest. There is a need for high quality, independently funded and performed, comparative studies on the MIGS to help make treatment decisions.
Collapse
Affiliation(s)
- Jullia A Rosdahl
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| | - Divakar Gupta
- Department of Ophthalmology, Duke University, Durham, NC27710, USA
| |
Collapse
|
15
|
Lindstrom R, Sarkisian SR, Lewis R, Hovanesian J, Voskanyan L. Four-Year Outcomes of Two Second-Generation Trabecular Micro-Bypass Stents in Patients with Open-Angle Glaucoma on One Medication. Clin Ophthalmol 2020; 14:71-80. [PMID: 32021070 PMCID: PMC6968820 DOI: 10.2147/opth.s235293] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2019] [Accepted: 12/17/2019] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION This study evaluated long-term reductions in intraocular pressure (IOP) and medication following implantation of 2 second-generation trabecular micro-bypass stents (iStent inject®) in eyes with open-angle glaucoma (OAG) not controlled on 1 preoperative medication. MATERIAL AND METHODS In this prospective interventional multi-surgeon study, standalone implantation of 2 iStent inject stents was performed in 57 eyes of 57 subjects with OAG, preoperative IOP of 18-30 mmHg on 1 medication, and preoperative post-washout IOP of 22-38 mmHg. The main outcome measures included the proportions of eyes achieving medication-free IOP ≤18 mmHg, IOP ≤15 mmHg, or ≥20% IOP reduction versus preoperative unmedicated IOP. Assessments included IOP, medications, visual acuity, visual field, pachymetry, complications, and interventions. Subjects were followed for 48 months with follow-up continuing in all eyes. RESULTS At Month 48 (n=57), 95% of eyes achieved an IOP reduction of ≥20% without medication versus preoperative washout IOP; and although they had eliminated medication, 81% of eyes still had an IOP reduction of ≥20% versus preoperative IOP on 1 medication. Mean 48-month unmedicated IOP decreased by 46% to 13.2±1.6 mmHg vs 24.4±1.3 mmHg preoperatively (p<0.0001), with 95% of medication-free eyes having IOP ≤18mmHg and 82% having IOP ≤15mmHg. Over the course of follow-up, 3 eyes had medication added and 1 eye underwent a secondary glaucoma surgery, and safety parameters were favorable. DISCUSSION Standalone iStent inject implantation in OAG patients on 1 preoperative medication resulted in average IOP reduction to ≤15 mmHg with the elimination of medication and favorable safety through 48 months. TRIAL REGISTRATION ClinicalTrials.gov identifier, NCT02868190.
Collapse
Affiliation(s)
| | | | | | | | - Lilit Voskanyan
- S.V. Malayan Ophthalmology Centre, Glaucoma Department, Yerevan, Armenia
| |
Collapse
|
16
|
Neuhann R, Neuhann T. Second-generation trabecular micro-bypass stent implantation: Retrospective analysis after 12- and 24-month follow-up. EYE AND VISION (LONDON, ENGLAND) 2020; 7:1. [PMID: 31938714 PMCID: PMC6953161 DOI: 10.1186/s40662-019-0169-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Accepted: 12/19/2019] [Indexed: 01/15/2023]
Abstract
BACKGROUND The study aimed to investigate the 24-month safety and efficacy of implantation of two second-generation iStent inject trabecular micro-bypass stents with concomitant cataract surgery. METHODS This consecutive case series included 164 eyes of 109 patients implanted with the iStent inject® device with concomitant cataract surgery. The series was comprised of eyes with primary open-angle glaucoma (n = 84), pseudoexfoliation glaucoma (n = 42), normal-tension glaucoma (n = 18), and ocular hypertension (n = 20). All 164 eyes reached 9-14 months of follow-up ("12-month consistent cohort"), with a subset of 88 eyes reaching 21-26 months of follow-up ("24-month consistent cohort"). Performance outcome measures included intraocular pressure (IOP) and number of glaucoma medications. Safety outcomes included intra- or postoperative complications, the need for secondary procedures and corrected distance visual acuity. Comparisons of change in continuous (e.g., IOP) and categorical (e.g., proportions of eyes on zero medications) measures between baseline and postoperative times were made with the paired t-test and McNemar's chi-squared test, respectively. RESULTS At 12 months postoperatively, IOP was reduced by 25.5% (from 20.0 ± 5.5 mmHg to 14.9 ± 2.0 mmHg; p < 0.001); at 24 months postoperatively, IOP was reduced by 26.6% (from 20.3 ± 6.1 mmHg to 14.9 ± 1.9 mmHg; p < 0.001). At 12 months postoperatively, mean number of glaucoma medications was reduced by 85.0% (from 2.0 ± 1.0 to 0.3 ± 0.8 medications; p < 0.001); at 24 months postoperatively, mean number of medications was reduced by 81.0% (from 2.1 ± 1.1 to 0.4 ± 0.8 medications; p < 0.001). After 12 months, 96.3% of eyes had an IOP ≤ 18 mmHg and 58.5% of eyes had an IOP ≤ 15 mmHg, with 81.1% of eyes free of any medication, compared to 1.8% of eyes medication-free in the 12-month cohort at baseline. After 24 months, 98.9% of eyes had an IOP ≤ 18 mmHg and 53.4% of eyes had an IOP ≤ 15 mmHg, with 72.7% free of medication compared to 1.1% of eyes medication-free in the 24-month cohort at baseline. Overall, a high safety profile was observed with no significant postoperative complications. CONCLUSIONS The insertion of iStent inject (comprised of two second-generation trabecular micro-bypass stents) with cataract surgery effectively provides a sustained reduction in IOP with a markedly improved medication burden up to 24 months postoperatively.
Collapse
Affiliation(s)
- Raphael Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| | - Tobias Neuhann
- Ophthalmologikum Dr.Neuhann, Augentagesklinik Marienplatz, Marienplatz 18-19, 80331 Munich, Germany
| |
Collapse
|
17
|
Manning D. Real-world Case Series of iStent or iStent inject Trabecular Micro-Bypass Stents Combined with Cataract Surgery. Ophthalmol Ther 2019; 8:549-561. [PMID: 31422555 PMCID: PMC6858412 DOI: 10.1007/s40123-019-00208-x] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Indexed: 10/28/2022] Open
Abstract
INTRODUCTION This real-world retrospective case series assessed 12-month effectiveness and safety following implantation of iStent® or iStent inject® trabecular micro-bypass with cataract surgery. METHODS Consecutive patients were implanted with either iStent (comprising 1 stent) or iStent inject (comprising 2 stents), together with cataract surgery. Most patients had primary open-angle glaucoma. Effectiveness outcomes through 12 months included intraocular pressure (IOP) and glaucoma medications. Proportional analyses were completed for eyes achieving IOP ≤ 18 mmHg, IOP ≤ 15 mmHg, or IOP reduction ≥ 20% from preoperative; and eyes on 0 medications or ≥ 2 medications. Safety outcomes included adverse events, secondary surgeries, visual acuity, and visual fields. RESULTS This analysis included 137 eyes (67 iStent, 70 iStent inject) with cataract and mild to moderate glaucoma or ocular hypertension. Over 73% of eyes in both groups had early disease, and ~ 22% had prior glaucoma surgery. At 12 months postoperatively, mean IOP decreased from 18.4 ± 4.2 mmHg to 14.2 ± 2.5 mmHg in iStent eyes (p < 0.0001), and from 20.4 ± 5.6 mmHg to 14.4 ± 2.1 mmHg in iStent inject eyes (p < 0.0001). The IOP reduction was significantly greater for iStent inject eyes than iStent eyes (6.0 mmHg versus 4.2 mmHg reduction, p = 0.034). Both groups had high proportions of patients achieving the 12-month IOP endpoints, although consistently greater proportions reached these endpoints after iStent inject than iStent: 95.7% versus 92.5% had IOP ≤ 18 mmHg, respectively; 74.3% versus 71.6% had IOP ≤ 15 mmHg, respectively; and 68.6% versus 62.7% had IOP reduction ≥ 20% from baseline, respectively. Mean medication burden at 12 months decreased from 1.8 ± 0.7 to 0.3 ± 0.5 medications in iStent eyes (84.0% reduction, p < 0.0001), and from 1.3 ± 0.9 to 0.1 ± 0.3 medications in iStent inject eyes (94.7% reduction, p < 0.0001). Significantly more iStent inject eyes were medication-free at 12 months than iStent eyes (92.9% versus 76.1% medication-free, respectively; p = 0.0068). Favorable safety included few adverse events, no secondary glaucoma surgeries, and stable visual acuity and visual fields in both groups. CONCLUSION Significant and safe IOP and medication reductions were achieved through 12 months after iStent or iStent inject implantation with cataract surgery. iStent inject eyes had greater absolute IOP reduction and more eyes medication-free versus iStent eyes. FUNDING Glaukos Corporation.
Collapse
Affiliation(s)
- David Manning
- Hunter Cataract and Eye Centre, Charlestown, NSW, Australia.
| |
Collapse
|
18
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. One-Year Comparative Evaluation of iStent or iStent inject Implantation Combined with Cataract Surgery in a Single Center. Adv Ther 2019; 36:2797-2810. [PMID: 31440981 PMCID: PMC6822971 DOI: 10.1007/s12325-019-01067-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Indexed: 11/20/2022]
Abstract
INTRODUCTION This retrospective consecutive case series assessed 12-month effectiveness and safety of iStent® or iStent inject® trabecular micro-bypass implants with cataract surgery in patients with open-angle glaucoma (OAG) in a real-world clinical setting. METHODS Effectiveness outcomes consisted of intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving IOP < 18, < 15, or < 12 mmHg; and proportional analysis of medication usage. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS This evaluation included 58 eyes with OAG (35 iStent, 23 iStent inject), with 96.6% of eyes having mild or moderate glaucoma. Diagnoses included primary open-angle glaucoma (the majority; 72.4%), pseudoexfoliative glaucoma, and pigmentary glaucoma. Baseline mean IOP and medications were statistically comparable between groups: 16.1 ± 3.6 mmHg on a mean of 1.8 ± 0.8 medications in the iStent group, and 16.2 ± 3.1 mmHg on a mean of 1.7 ± 0.8 medications in the iStent inject group. Twelve months after stent-cataract surgery, mean IOP was significantly lower in the iStent inject group than in the iStent group (13.1 mmHg vs. 15.4 mmHg, respectively; p < 0.001), and the percent reduction in IOP from baseline was significantly greater in iStent inject eyes than in iStent eyes (19.1% vs. 4.3% reduction, respectively; p < 0.001). At 12 months postoperative, significantly greater proportions of iStent inject eyes than iStent eyes achieved IOP < 18 mmHg (100% vs. 80.0% of eyes, respectively; p = 0.035), IOP < 15 mmHg (73.9% vs. 34.3% of eyes, respectively; p = 0.003), and IOP < 12 mmHg (26.1% vs. 0% of eyes, respectively; p = 0.002). Meanwhile, both groups achieved significant medication reductions at 12 months vs. baseline (94.1% reduction in iStent inject eyes, p < 0.0001; and 72.2% reduction in iStent eyes, p < 0.0001), with the percent reduction being significantly greater in iStent inject eyes than in iStent eyes (p = 0.023). At 12 months, mean number of medications was significantly lower in iStent inject eyes than iStent eyes (0.1 vs. 0.5 medications, respectively; p = 0.021), and significantly more iStent inject eyes (95.7%) than iStent eyes (71.4%) were off medications entirely (p = 0.021). A similarly high safety profile was observed in both groups. CONCLUSION iStent or iStent inject implantation with cataract surgery resulted in substantial and safe reductions in IOP and medications through 12 months postoperative. Consistent with prior observations, greater efficacy was observed with iStent inject than with iStent. FUNDING The Rapid Service Fees were funded by Glaukos Corporation.
Collapse
Affiliation(s)
- Ricardo Augusto Paletta Guedes
- Paletta Guedes Eye Institute, Juiz de Fora, Minas Gerais, Brazil.
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
| | | | | | | | - Alfredo Chaoubah
- Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil
| |
Collapse
|
19
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Second-Generation Trabecular Micro-Bypass Stents as Standalone Treatment for Glaucoma: A 36-Month Prospective Study. Adv Ther 2019; 36:1606-1617. [PMID: 31119690 PMCID: PMC6824385 DOI: 10.1007/s12325-019-00984-9] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Indexed: 11/13/2022]
Abstract
INTRODUCTION To evaluate long-term outcomes following stand-alone implantation of two second-generation trabecular micro-bypass stents (iStent inject®, Glaukos Corp., San Clemente, CA, USA) in eyes with predominantly primary open-angle glaucoma (POAG) and considerable preoperative disease burden. METHODS Eyes with POAG, pseudoexfoliative glaucoma (PXG), appositional narrow-angle glaucoma (NAG, with open-angle configuration in the area of implantation), or secondary glaucoma were included in this prospective, non-randomized, consecutive case series. All eyes underwent ab interno iStent inject implantation as a sole procedure. Assessments through 36 months included IOP, medications, corrected distance visual acuity (CDVA), secondary glaucoma surgeries, and complications and adverse events. RESULTS Two iStent inject stents were implanted in 44 consecutive eyes (POAG = 38, PXG = 4, appositional NAG = 1, secondary neovascular glaucoma = 1) of 31 patients, and 33 eyes had 36-month follow-up data. Preoperative mean IOP was 25.3 ± 6.0 mmHg on a mean of 2.98 ± 0.88 medications, with 75% of eyes on 3-5 medications, no eyes medication-free, and 50% of eyes with history of prior glaucoma surgery. At 36 months postoperatively, mean IOP reduced by 42% to 14.6 ± 2.0 mmHg (p < 0.0001) and 87.9% of eyes achieved an IOP reduction of ≥ 20% versus preoperatively. In addition, 97% of eyes reached IOP ≤ 18 mmHg (vs. 9.1% preoperatively; p < 0.0001) and 70.0% of eyes reached IOP ≤ 15 mmHg (vs. 2.3% preoperatively; p < 0.0001). Mean medication burden decreased by 82% to 0.55 ± 0.79 (p < 0.0001), and 61% of eyes became medication-free. All eyes maintained or decreased their 36-month medication burden versus preoperatively. Safety was favorable, including minimal adverse events and stable CDVA through 36 months postoperatively. CONCLUSION This real-world cohort of glaucomatous eyes with substantial preoperative disease burden experienced significant, sustained, safe IOP and medication reductions through 36 months following stand-alone iStent inject implantation. FUNDING Article processing charges and writing assistance were provided by Glaukos Corp. (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
- Department of Ophthalmology, Buergerhospital, Frankfurt, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
20
|
Samuelson TW, Sarkisian SR, Lubeck DM, Stiles MC, Duh YJ, Romo EA, Giamporcaro JE, Hornbeak DM, Katz LJ, Bartlett W, Buznego C, Johnson S, D'Ambrosio FA, Dehning D, DuBiner H, Goyal R, Hughes B, Marquis RE, Noecker R, Tauber S, Perez BR, Roel L, Sarkisian S, Silverstein S, Day S, Solomon K, Tyson F, Vold S, Samuelson T, Simmons S, Stiles M, Nguyen QH, Bashford KP, Flowers B, Flynn WJ, Gira J, Okeke C, Reiss GR, Tyson SL, Parkhurst G, Linn J, Lubeck D, Solomon J, Singh IP, Johnson RD, Lin C, Kim JW, Crane CJ, Cotter F. Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract. Ophthalmology 2019; 126:811-821. [DOI: 10.1016/j.ophtha.2019.03.006] [Citation(s) in RCA: 94] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 03/04/2019] [Accepted: 03/04/2019] [Indexed: 10/27/2022] Open
|
21
|
Gallardo MJ, Supnet RA. Three-year outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic population with primary open-angle glaucoma. Clin Ophthalmol 2019; 13:869-879. [PMID: 31239633 PMCID: PMC6554518 DOI: 10.2147/opth.s189071] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 02/19/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: To present long-term, real-world outcomes after implanting one trabecular micro-bypass stent with cataract surgery for primary open-angle glaucoma (POAG) in a predominantly Hispanic patient population. Patients and methods: This retrospective, consecutive case series evaluated intraocular pressure (IOP), medications, and safety through 36 months after implanting one iStent® during phacoemulsification cataract surgery. Eyes were stratified into 2 subgroups classified by preoperative IOP and surgical goal. The Controlled Group had IOP <18 mmHg on ≥1 medications, and goal to reduce medications. The Uncontrolled Group had IOP ≥18 mmHg and/or maximum tolerated medication load, and goal to reduce IOP. Assessments included IOP, medications, visual fields (VF), retinal nerve fiber layer thickness (RNFL), adverse events, and secondary surgeries. Results: Of 168 total operated eyes, 87 eyes (49 Controlled, 38 Uncontrolled) completed 36 months of follow-up and comprise the Consistent Cohort in this report. At baseline, 79.6% (39/49) of Controlled eyes and 71.1% (27/38) of Uncontrolled eyes were from Hispanic patients. In the Controlled Group desiring medication reduction, mean medications were reduced by 77.3% (2.6 medications preoperatively vs 0.6 at 36 months; p<0.001. All Controlled eyes maintained or reduced medications versus preoperative; no eyes were on ≥3 medications (vs 61.2% preoperatively); and 58.3% were medication-free (vs 0% preoperatively). In the Uncontrolled Group desiring IOP reduction, mean IOP decreased by 31.2% (19.4 mmHg preoperatively vs 13.4 mmHg at 36 months; p<0.001), 91.7% of eyes achieved IOP ≤18 mmHg, 69.4% reached IOP ≤15 mmHg, and 77.8% decreased IOP ≥20% vs baseline. Uncontrolled eyes also experienced a 45.3% medication reduction (2.2 medications preoperatively vs 1.2 at 36 months; p<0.001). Favorable safety included no intraoperative complications, and stable VF and RNFL through 36 months. Conclusion: In this predominantly Hispanic patient cohort, significant IOP and medication reductions were sustained safely through 36 months after iStent implantation during cataract surgery.
Collapse
Affiliation(s)
- Mark J Gallardo
- El Paso Eye Surgeons, PA, El Paso, TX, USA.,Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, TX, USA
| | | |
Collapse
|
22
|
Fechtner RD, Voskanyan L, Vold SD, Tetz M, Auffarth G, Masood I, Au L, Khouri AS, Ahmed IIK, Saheb H. Five-Year, Prospective, Randomized, Multi-Surgeon Trial of Two Trabecular Bypass Stents versus Prostaglandin for Newly Diagnosed Open-Angle Glaucoma. Ophthalmol Glaucoma 2019; 2:156-166. [PMID: 32672584 DOI: 10.1016/j.ogla.2019.03.004] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Revised: 01/14/2019] [Accepted: 03/12/2019] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate 5-year safety and efficacy of 2 trabecular micro-bypass stents versus prostaglandin as initial stand-alone treatment for newly diagnosed, treatment-naive primary open-angle glaucoma (POAG). DESIGN Prospective, randomized, controlled, multi-surgeon clinical trial. PARTICIPANTS Enrolled eyes (n = 101) were phakic and had a confirmed POAG diagnosis, normal angle anatomy, mean diurnal intraocular pressure (IOP) 21 to 40 mmHg, and vertical cup-to-disc (C:D) ratio ≤0.9. METHODS Eyes were randomized (1:1) to receive either 2 stents (iStent trabecular micro-bypass; Glaukos Corporation, San Clemente, CA) or once-daily topical travoprost. MAIN OUTCOME MEASURES The primary and secondary efficacy end points were the change from screening in mean diurnal IOP at months 12 and 24, respectively, without glaucoma surgery or add-on medication (any medication in stent eyes or a second medication in travoprost eyes). Two additional secondary end points were the proportion of eyes achieving treatment success at months 12 and 24, defined as IOP 6 to 18 mmHg without additional medication or glaucoma surgery. This report shows these efficacy measures through 60 months. Safety measures included best-corrected visual acuity, C:D ratio, visual field, pachymetry, complications, and adverse events. RESULTS Of 101 enrolled eyes (54 stent eyes, 47 travoprost eyes), 90 eyes (49 stent eyes, 41 travoprost eyes) completed 5-year follow-up. Five-year mean diurnal IOP was 16.5±1.2 mmHg in stent eyes (35.3% reduced vs. 25.5±2.5 mmHg preoperatively; P < 0.0001) and 16.3±1.9 mmHg in travoprost eyes (35.1% reduced vs. 25.1±4.6 mmHg preoperatively; P < 0.0001). During follow-up, add-on medication was initiated in 12 stent eyes (22.2% of the initial 54-eyes) and 18 travoprost eyes (38.3% of the initial 47-eyes). By 5 years, 17% (6/35) of stent eyes and 44% (14/32) of travoprost eyes needed add-on medication to control IOP (P = 0.017). Treatment success was achieved in 77% (27/35) of stent eyes and 53% (17/32) of travoprost eyes (P = 0.04). Both groups exhibited excellent safety. CONCLUSIONS This prospective randomized trial demonstrates 5-year effectiveness and safety of 2 trabecular bypass stents in patients with newly diagnosed, treatment-naive POAG, with comparably favorable outcomes as topical prostaglandin.
Collapse
Affiliation(s)
- Robert D Fechtner
- State University of New York Upstate Medical University, Syracuse, New York.
| | | | | | - Manfred Tetz
- Berlin Eye Research Institute and Augenklinik Spreebogen, Berlin, Germany
| | - Gerd Auffarth
- Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany
| | - Imran Masood
- Birmingham City Hospital, Birmingham, United Kingdom
| | - Leon Au
- Manchester Royal Eye Hospital, Manchester, United Kingdom
| | | | | | - Hady Saheb
- Mcgill University, Montreal, Quebec, Canada
| |
Collapse
|
23
|
Neuhann TH, Hornbeak DM, Neuhann RT, Giamporcaro JE. Long-term effectiveness and safety of trabecular microbypass stent implantation with cataract surgery in patients with glaucoma or ocular hypertension: Five-year outcomes. J Cataract Refract Surg 2019; 45:312-320. [DOI: 10.1016/j.jcrs.2018.10.029] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 08/13/2018] [Accepted: 10/01/2018] [Indexed: 11/28/2022]
|
24
|
Micropulse Transscleral Cyclophotocoagulation: A Look at Long-Term Effectiveness and Outcomes. Ophthalmol Glaucoma 2019; 2:167-171. [PMID: 32672586 DOI: 10.1016/j.ogla.2019.02.002] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Revised: 01/28/2019] [Accepted: 02/01/2019] [Indexed: 11/21/2022]
Abstract
PURPOSE To investigate the long-term effectiveness of intraocular pressure (IOP) and medication reduction in patients who have undergone micropulse transscleral cyclophotocoagulation (mTS-CPC). DESIGN Retrospective chart review. PARTICIPANTS A total of 73 eyes of 62 patients treated no more than 1 time with mTS-CPC in a practice in New York City with at least 1 year of follow-up. METHODS Treatment was 100 seconds of mTS-CPC with energy titrated on the basis of visual acuity. Paired t test and multivariable analysis were performed with SAS (SAS Institute Inc, Cary, NC). MAIN OUTCOME MEASURES Visual acuity, IOP, medication burden, phthisis, and development of macular edema were followed. RESULTS Average initial IOP was 25.5±9.4, and average number of initial medications was 3.1±1.1. At 1 year, average IOP was 13.8±7.0 (46% reduction) and average number of medications was 2.5±1.0 (19% reduction). A total of 11 of 15 patients (73.3%) initially taking an oral carbonic anhydrase inhibitor before CPC did not require the oral carbonic anhydrase inhibitor 1 year after treatment. Seventy-six percent of patients obtained at least 20% IOP reduction. Multivariate analysis found IOP reduction was associated with power used and preoperative IOP, whereas medication reduction was associated with initial medication burden. Notably, there was a 57% reduction in IOP at 2500 mW power and a 30% reduction at 2000 mW power. No patients developed macular edema or phthisis from the procedure. Some 18.8% of patients with 20/400 vision or better experienced persistent vision loss of ≥2 lines after the procedure, and 10% of patients with light perception to count finger vision progressed to no light perception (NLP) after the procedure. Of patients with 20/400 vision or better, 12.5% gained ≥2 lines of visual acuity on the Snellen chart at the postoperative year 1 visit. In addition, 15.4% of patients with count fingers to NLP vision improved at the postoperative year 1 visit after treatment. One of 6 patients (16.7%) with NLP gained vision at the postoperative year 1 visit. CONCLUSIONS This study provides evidence that mTS-CPC is a clinically useful procedure associated with good long-term medication burden reduction and IOP reduction that follows a dose-response pattern related to power used.
Collapse
|
25
|
Guedes RAP, Gravina DM, Lake JC, Guedes VMP, Chaoubah A. Intermediate Results of iStent or iStent inject Implantation Combined with Cataract Surgery in a Real-World Setting: A Longitudinal Retrospective Study. Ophthalmol Ther 2019; 8:87-100. [PMID: 30721523 PMCID: PMC6393257 DOI: 10.1007/s40123-019-0166-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Indexed: 11/02/2022] Open
Abstract
INTRODUCTION In this real-world, retrospective, comparative study we evaluated 6-month performance and safety in consecutive eyes following implantation of the iStent® or iStent inject® trabecular micro-bypass device with concomitant cataract surgery. METHODS Performance outcomes included intraocular pressure (IOP) reduction; glaucoma medication reduction; proportions of eyes achieving an IOP of < 18, < 16, < 14, or < 12 mmHg; and proportions of eyes on 0, 1, 2, or ≥ 3 medications. Safety outcomes included adverse events, secondary surgeries, and best-corrected visual acuity (BCVA). RESULTS A total of 73 eyes with open-angle glaucoma and cataract were included in the study; of these, 38 eyes were implanted with the iStent device and 35 were implanted with the iStent inject device. The two groups of patients had similar baseline characteristics, with the exception of mean age and medication burden (both higher in patients receiving the iStent inject device); over 90% of eyes in both groups had early glaucoma. At 6 months after surgery, mean IOP had fallen from 16.5 ± 3.9 to 13.9 ± 2.3 mmHg in eyes with the iStent implant (p < 0.001), and from 17.3 ± 3.0 to 12.7 ± 1.8 mmHg in those with the iStent inject implant (p < 0.001). This reduction was significantly greater in the iStent inject eyes than in the iStent eyes (26.6 vs. 15.8%) (p = 0.005). Significantly more eyes receiving the iStent inject device compared to the iStent device achieved an IOP of < 18 mmHg at 6 months post surgery (100 vs. 86.8%) (p = 0.033). Average medication usage was reduced from 1.8 to 0.4 medications in iStent eyes (p < 0.001) and from 2.3 to 0.4 medications in iStent inject eyes (p < 0.001). Over 70% of eyes in both groups became medication-free by 6 months post implantation. Adverse events in iStent eyes were mild and resulted in no sequelae; two iStent eyes underwent non-penetrating deep sclerectomy during follow-up. No complications or secondary surgeries were noted in iStent inject eyes. All eyes in both groups maintained or showed improved BCVA versus baseline. CONCLUSION Significant and safe IOP and medication reductions were observed after iStent or iStent inject implantation with concomitant cataract surgery. Trends toward greater effectiveness and fewer adverse events were observed with the iStent inject device compared with the iStent device. FUNDING Article processing charges were provided by Glaukos Corporation.
Collapse
Affiliation(s)
| | | | - Jonathan Clive Lake
- Cataract and Glaucoma Department, Brasilia Vision Hospital, Brasilia, DF, Brazil
| | | | | |
Collapse
|
26
|
Hengerer FH, Auffarth GU, Riffel C, Conrad-Hengerer I. Prospective, Non-randomized, 36-Month Study of Second-Generation Trabecular Micro-Bypass Stents with Phacoemulsification in Eyes with Various Types of Glaucoma. Ophthalmol Ther 2018; 7:405-415. [PMID: 30430427 PMCID: PMC6258575 DOI: 10.1007/s40123-018-0152-8] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Indexed: 11/24/2022] Open
Abstract
Introduction The aim of this study was to assess 36-month outcomes after cataract surgery and implantation of two second-generation trabecular micro-bypass stents (iStent inject, Glaukos Corporation, San Clemente, CA, USA) into eyes with predominantly primary open-angle glaucoma (POAG) or pseudoexfoliative glaucoma (PEX). Methods This prospective, non-randomized, consecutive cohort study included eyes with POAG (n = 60), PEX (n = 15), appositional narrow-angle (n = 4), pigmentary (n = 1), or neovascular (secondary) (n = 1) glaucoma and cataract requiring surgery. All eyes (n = 81) underwent ab interno iStent inject implantation following cataract surgery. Effectiveness endpoints through 36 months included intraocular pressure (IOP), number of medications, and proportion of eyes with ≥ 20% IOP reduction, IOP ≤ 18 mmHg, and IOP ≤ 15 mmHg. Safety measures included corrected distance visual acuity (CDVA), adverse events, and secondary surgeries. Outcomes were evaluated for the overall cohort, and for the POAG and PEX subgroups. Results Preoperatively, 32.1% of eyes had undergone prior glaucoma surgery, 56% were on 3–4 medications, and 1 eye (1%) was medication-free. At 36 months postoperatively, mean IOP reduced by 37% (14.3 ± 1.7 mmHg versus 22.6 ± 6.2 mmHg preoperatively), and mean medication burden decreased by 68% (0.8 ± 0.9 versus 2.5 ± 1.1 medications preoperatively). IOP reduced by ≥ 20% in 78% of eyes; 100% of eyes reached IOP ≤ 18 mmHg and 71% reached ≤ 15 mmHg. Medication burden reduced considerably: 22 eyes (54%) were medication-free compared to 1 eye (1%) preoperatively; 1 eye (2%) required ≥ 3 medications compared to 45 eyes (56%) preoperatively; and 92.7% of eyes required reduced medications postoperatively. From 3 through 36 months, mean IOP remained ≤ 15.0 mmHg, and mean number of medications remained ≤ 0.9. Outcomes in the POAG and PEX subgroups included 33% and 32% lower IOP, and 68% and 64% fewer medications, respectively. iStent inject showed a favorable safety profile, including no intraoperative complications, minimal adverse events, and a stable CDVA. Conclusion This real-world cohort of eyes with various types of glaucoma and considerable disease burden exhibited durable and safe IOP and medication reductions through 36 months following iStent inject implantation with cataract surgery. Outcomes were similarly beneficial in eyes with POAG and PEX. Funding Article processing charges were funded by Glaukos Corporation (San Clemente, CA, USA).
Collapse
Affiliation(s)
- Fritz H Hengerer
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Heidelberg, Germany
| | | | | |
Collapse
|
27
|
Myers JS, Masood I, Hornbeak DM, Belda JI, Auffarth G, Jünemann A, Giamporcaro JE, Martinez-de-la-Casa JM, Ahmed IIK, Voskanyan L, Katz LJ. Prospective Evaluation of Two iStent ® Trabecular Stents, One iStent Supra ® Suprachoroidal Stent, and Postoperative Prostaglandin in Refractory Glaucoma: 4-year Outcomes. Adv Ther 2018; 35:395-407. [PMID: 29476443 PMCID: PMC5859115 DOI: 10.1007/s12325-018-0666-4] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Indexed: 12/01/2022]
Abstract
Introduction This study evaluates long-term outcomes of two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin in eyes with refractory open angle glaucoma (OAG). Methods Prospective ongoing 5-year study of 80 eligible subjects (70 with 4-year follow-up) with OAG and IOP ≥ 18 mmHg after prior trabeculectomy and while taking 1–3 glaucoma medications. Subjects received two iStent® trabecular micro-bypass stents, one iStent Supra® suprachoroidal stent, and postoperative travoprost. Postoperative IOP was measured with medication and annually following medication washouts. Performance was measured by the proportion of eyes with ≥ 20% IOP reduction on one medication (the protocol-specified prostaglandin) versus preoperative medicated IOP (primary outcome); and the proportion of eyes with postoperative IOP ≤ 15 and ≤ 18 mmHg on one medication (secondary outcome). Additional clinical and safety data included medications, visual field, pachymetry, gonioscopy, adverse events, visual acuity, and slit-lamp and fundus examinations. Results Preoperatively, mean medicated IOP was 22.0 ± 3.1 mmHg on 1.2 ± 0.4 medications, and mean unmedicated IOP was 26.4 ± 2.4 mmHg. Postoperatively, among eyes without later cataract surgery, mean medicated IOP at all visits through 48 months was ≤ 13.7 mmHg (≥ 37% reduction), and annual unmedicated IOP was ≤ 18.4 mmHg (reductions of ≥ 30% vs. preoperative unmedicated IOP and ≥ 16% vs. preoperative medicated IOP). At all postoperative visits among eyes without additional surgery or medication, ≥ 91% of eyes had ≥ 20% IOP reduction on one medication versus preoperative medicated IOP. At month 48, 97 and 98% of eyes achieved IOP ≤ 15 and ≤ 18 mmHg, respectively, on one medication. Six eyes required additional medication, no eyes required additional glaucoma surgery, and safety measurements were favorable throughout follow-up. Conclusion IOP control was achieved safely with two trabecular micro-bypass stents, one suprachoroidal stent, and postoperative prostaglandin. This microinvasive, ab interno approach introduces a possible new treatment option for refractory disease. Trial Registration NCT01456390. Funding Glaukos Corporation. Electronic supplementary material The online version of this article (10.1007/s12325-018-0666-4) contains supplementary material, which is available to authorized users.
Collapse
|
28
|
Katz LJ, Erb C, Carceller Guillamet A, Fea AM, Voskanyan L, Giamporcaro JE, Hornbeak DM. Long-term titrated IOP control with one, two, or three trabecular micro-bypass stents in open-angle glaucoma subjects on topical hypotensive medication: 42-month outcomes. Clin Ophthalmol 2018; 12:255-262. [PMID: 29440867 PMCID: PMC5798569 DOI: 10.2147/opth.s152268] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose Evaluate long-term outcomes after one, two, or three trabecular micro-bypass stents implanted in a standalone procedure in eyes with open-angle glaucoma taking ocular hypotensive medication. Patients and methods Prospective randomized ongoing study of 119 subjects (109 with 42-month follow-up) with open-angle glaucoma, preoperative intraocular pressure (IOP) 18-30 mmHg on one to three glaucoma medications, and unmedicated (post-washout) IOP 22-38 mmHg. Subjects were randomized to receive one (n=38), two (n=41), or three (n=40) iStent trabecular micro-bypass stents in a standalone procedure. Postoperatively, IOP was measured with medication and annually following washout. Data included IOP, medications, gonioscopy, pachymetry, visual field, visual acuity, adverse events, and slit-lamp and fundus examinations. Results Preoperative mean medicated IOP was 19.8±1.3 mmHg on 1.71 medications in one-stent eyes, 20.1±1.6 mmHg on 1.76 medications in two-stent eyes, and 20.4±1.8 mmHg on 1.53 medications in three-stent eyes. Post-washout IOP prior to stent implantation was 25.0±1.2, 25.0±1.7, and 25.1±1.9 mmHg in the three groups, respectively. Postoperatively, Month 42 medicated IOP was 15.0±2.8, 15.7±1.0 and 14.8±1.3 mmHg in the three groups, and post-washout IOP (Months 36-37) was 17.4±0.9, 15.8±1.1 and 14.2±1.5 mmHg, respectively. IOP reduction ≥20% without medication was achieved in 89%, 90%, and 92% of one-, two-, and three-stent eyes, respectively, at Month 12; and in 61%, 91%, and 91% of eyes, respectively, at Month 42. The need for additional medication remained consistent at Months 12 and 42 in multi-stent eyes (four two-stent eyes and three three-stent eyes at both time points), whereas it increased in single-stent eyes (four eyes at Month 12 versus 18 eyes at Month 42). Safety parameters were favorable in all groups. Conclusion The standalone implantation of either single or multiple iStent® device(s) produced safe, clinically meaningful IOP and medication reductions through 42 months postoperatively, with incrementally greater and more sustained reductions in multi-stent eyes.
Collapse
Affiliation(s)
- L Jay Katz
- Glaucoma Service, Wills Eye Hospital, Philadelphia, PA, USA
| | - Carl Erb
- Glaucoma Service, Eye Clinic Wittenbergplatz, Berlin, Germany
| | | | - Antonio M Fea
- Department of Surgical Sciences, University of Torino, Torino, Italy
| | - Lilit Voskanyan
- Glaucoma Service, S. V. Malayan Ophthalmology Centre, Yerevan, Armenia
| | - Jane Ellen Giamporcaro
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| | - Dana M Hornbeak
- Department of Clinical Research and Medical Affairs, Glaukos Corporation, San Clemente, CA, USA
| |
Collapse
|
29
|
Berdahl J, Voskanyan L, Myers JS, Hornbeak DM, Giamporcaro JE, Katz LJ, Samuelson TW. Implantation of two second-generation trabecular micro-bypass stents and topical travoprost in open-angle glaucoma not controlled on two preoperative medications: 18-month follow-up. Clin Exp Ophthalmol 2017; 45:797-802. [PMID: 28384377 PMCID: PMC5724487 DOI: 10.1111/ceo.12958] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 02/16/2017] [Accepted: 04/03/2017] [Indexed: 11/30/2022]
Abstract
Importance Additional data are sought regarding treatment options for glaucoma, a major cause of global blindness. Background The study assessed outcomes following standalone implantation of two second‐generation trabecular micro‐bypass stents and postoperative topical prostaglandin in eyes with open‐angle glaucoma not controlled on two preoperative medications. Design The study design is a prospective, nonrandomized, open‐label study at a tertiary‐care ophthalmology centre. Participants Subjects had open‐angle glaucoma with preoperative intraocular pressure of 18–30 mmHg on two medications, a medication washout phase, and post‐washout intraocular pressure of 22–38 mmHg. All subjects (N = 53) have been followed for 18 months. Methods One day following implantation of two second‐generation trabecular micro‐bypass stents, subjects started topical travoprost. Medication washout was repeated at month 12. Main Outcome Measures The main outcome measure was the proportion of eyes with intraocular pressure reduction ≥ 20% versus medicated baseline intraocular pressure with reduction of one medication at 12 months. Results At 12 months, 91% of eyes achieved intraocular pressure reduction ≥ 20% with reduction of one medication. All eyes had intraocular pressure ≤ 18 mmHg with reduction of one medication, and 87% had intraocular pressure ≤ 15 mmHg. Mean intraocular pressure on one medication was ≤ 13.0 mmHg (≥ 34% reduction) through 18 months. Mean post‐washout intraocular pressure at month 13 was 33% lower than preoperative unmedicated intraocular pressure. No adverse events occurred through 18 months. Conclusions and Relevance In open‐angle glaucoma eyes on two preoperative medications, treatment with two second‐generation trabecular stents and one postoperative prostaglandin resulted in mean intraocular pressure ≤ 13 mmHg with reduction of one medication, with favourable safety. These findings show the utility of second‐generation trabecular bypass with postoperative prostaglandin in patients with open‐angle glaucoma.
Collapse
Affiliation(s)
- John Berdahl
- Vance Thompson Vision, Sioux Falls, South Dakota, USA
| | | | - Jonathan S Myers
- Wills Eye Hospital, Jefferson Medical College, Philadelphia, Pennsylvania, USA
| | | | | | - L Jay Katz
- Wills Eye Hospital, Jefferson Medical College, Philadelphia, Pennsylvania, USA
| | | |
Collapse
|