1
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
2
|
Fang M, Airen S, Jiang H, Wang J. Ocular surface microvascular response and its relation to contact lens fitting and ocular comfort: an update of recent research. Clin Exp Optom 2021; 104:661-671. [PMID: 33689669 DOI: 10.1080/08164622.2021.1878867] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
This review examines vascular responses in the ocular surface to contact lens wear and its relation to lens fitting characteristics and contact lens-related discomfort. A search of PubMed was performed to find original research in English, within the past 10 years, that studied the ocular surface, including lid-wiper vascular responses to the lens. The interaction between the lens and ocular surface triggers vascular responses, impacting the lens fitting and contact lens-related discomfort. Contact lens-related discomfort is a multifactorial event, which is affected by lens characteristics. Overall, contact lenses with low modulus and a relatively tight fit produce significant ocular comfort. If an appropriate lens fit is achieved, lens fitting characteristics may not play a critical role in contact lens-related discomfort. On the other hand, the pathogenic and vascular changes of lid-wiper vascular responses appear to play an essential role in developing contact lens-related discomfort, in concert with reactions of the cornea (compression and staining) and conjunctiva (indentation and staining). Robust evaluation of lid-wiper changes at the cellular and microvascular level may hold the key to better understanding the mechanism of contact lens-related discomfort and reveal strategies for eliminating lid wiper epitheliopathy and improving ocular comfort in contact lens wearers.
Collapse
Affiliation(s)
- Min Fang
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, Guangdong, China.,School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA
| | - Shriya Airen
- School of Medicine, University of Miami Miller, Miami, FL, USA
| | - Hong Jiang
- School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA.,Department of Neurology, School of Medicine, University of Miami Miller, Miami, FL, USA
| | - Jianhua Wang
- School of Medicine, Bascom Palmer Eye Institute, University of Miami Miller, Miami, FL, USA
| |
Collapse
|
3
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
4
|
Woods J, Jones D, Jones L, Jones S, Hunt C, Chamberlain P, McNally J. Ocular health of children wearing daily disposable contact lenses over a 6-year period. Cont Lens Anterior Eye 2021; 44:101391. [DOI: 10.1016/j.clae.2020.11.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/29/2020] [Accepted: 11/22/2020] [Indexed: 12/26/2022]
|
5
|
Brennan N, Ruston D, Meyler J. Letter to the Editor: "Silicone hydrogel daily disposable benefits: The evidence". Cont Lens Anterior Eye 2020; 43:308-309. [PMID: 32276750 DOI: 10.1016/j.clae.2020.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Noel Brennan
- Clinical Research Fellow Myopia ControlPlatform Johnson & Johnson Vision Care, Inc., United Kingdom
| | | | - John Meyler
- Johnson & Johnson Medical Ltd., United Kingdom
| |
Collapse
|
6
|
Efron N, Brennan NA, Chalmers RL, Jones L, Lau C, Morgan PB, Nichols JJ, Szczotka-Flynn LB, Willcox MD. Thirty years of 'quiet eye' with etafilcon A contact lenses. Cont Lens Anterior Eye 2020; 43:285-297. [PMID: 32278644 DOI: 10.1016/j.clae.2020.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/27/2020] [Accepted: 03/28/2020] [Indexed: 11/17/2022]
Abstract
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | | | | | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charis Lau
- Johnson & Johnson Vision, Inc, Jacksonville, FL, USA
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, UK
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, USA
| | - Loretta B Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Department of Ophthalmology & Visual Sciences, Case Western Reserve University, Cleveland, OH, USA
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
7
|
Sulley A, Dumbleton K. Silicone hydrogel daily disposable benefits: The evidence. Cont Lens Anterior Eye 2020; 43:298-307. [PMID: 32098715 DOI: 10.1016/j.clae.2020.02.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/18/2020] [Accepted: 02/12/2020] [Indexed: 10/24/2022]
Abstract
Daily disposable (DD) contact lenses first came to the market approximately 25 years ago and eye care professionals (ECPs) started prescribing silicone hydrogel (SiH) contact lenses, primarily for extended or continuous wear, approximately 20 years ago. It has now been over ten years since SiH DD contact lenses have been available, and while SiH materials are routinely prescribed by ECPs for reusable daily wear, hydrogel materials are still frequently selected for the DD modality of contact lens wear. This article reviews the evidence to support the benefits of both a DD modality and SiH materials and how patients' needs may be met with SiH DD contact lenses, with respect to clinical performance, health outcomes, satisfaction, compliance and convenience. Factors which may enable or constrain ECPs from prescribing SiH DD contact lenses, as opposed to hydrogel DD and reusable contact lenses, for more of their patients are discussed with the objective of providing ECPs with a greater understanding of the advantages that can be afforded by prescribing SiH DD contact lenses to both their new and existing contact lens wearers.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- Clinical Research Scientist and Consultant, Berkeley, CA, USA; Associate Clinical Professor, School of Optometry, University of California Berkeley, CA, USA.
| |
Collapse
|