1
|
Atchison DA, Charman WN. Accommodating version of a schematic eye for emmetropia and myopia. Ophthalmic Physiol Opt 2024. [PMID: 39450668 DOI: 10.1111/opo.13406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 09/30/2024] [Accepted: 10/06/2024] [Indexed: 10/26/2024]
Abstract
AIM To develop an accommodating, wide-angle, schematic eye for emmetropia and myopia in which spectacle refraction and accommodation level are input parameters. METHOD The schematic eye is based on an earlier unaccommodated refraction-dependent eye for myopia developed by Atchison in 2006. This has a parabolic gradient index lens and parameters derived from biometric and optical measurements on young adults. Several parameters are linearly dependent upon spectacle refraction (anterior radius of curvature of the cornea, axial length and vertex radii of curvature and conic asphericities of a biconic retina). The new accommodated schematic eye incorporates accommodation-dependent changes in several lens-related parameters. These changes are based on literature values for anterior chamber depth, lens thickness, vitreous chamber depth, lens surface radii of curvature and lens front surface asphericity. A parabolic variation of refractive index with relative distance from the lens centre is retained, with the same edge and centre refractive indices as the earlier model, but the distribution has been manipulated to maintain focus near the retina for the emmetropic case at 0 and 4 D accommodation. The asphericity of the lens back surface is changed so that spherical aberration and peripheral refraction approximately match typical literature trends. The model is used to compare spherical aberration and peripheral refraction in eyes with up to 4 D of myopia and 4 D of accommodation. RESULTS The levels of spherical aberration in the unaccommodated schematic eyes are similar to literature values for young adults, but the changes in spherical aberration with accommodation are approximately two-thirds of that found in an experimental study. As intended, peripheral refractions in the accommodated schematic eyes are similar to those of their unaccommodated counterparts. CONCLUSION The wide-angle model extends the range of schematic eyes to include both refraction and accommodation as variable input parameters. It may be useful in predicting aspects of retinal image quality.
Collapse
Affiliation(s)
- David A Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - W Neil Charman
- Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| |
Collapse
|
2
|
Zhang G, Jiang J, Wei Q, Qu C. Effects of accommodation on geometrical parameters of human lens: A systematic review and meta-analysis. Heliyon 2024; 10:e29298. [PMID: 38681553 PMCID: PMC11053204 DOI: 10.1016/j.heliyon.2024.e29298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 03/29/2024] [Accepted: 04/04/2024] [Indexed: 05/01/2024] Open
Abstract
Purpose To investigate the effects of accommodation on the geometrical parameters of human lens. Methods Eight databases from inception to November 2023 were used for the literature search: CNKI, CBM, VIP, Wan-Fang, PubMed, Web of Science, EMBASE, and the Cochrane Library. The Methodological Index for Non-randomized Studies was used to assess the risk of bias. The PRISMA were followed and the following outcomes were taken into consideration: lens diameter (LD), lens thickness (LT), anterior curvature radius (ACR), posterior curvature radius (PCR), lens center position (LCP), and total cross-sectional area (TCSA). This systematic review was registered on an international platform for registered systematic reviews and meta-analysis (INPLASY202260085). Results A total of 19 studies were included. LT increased by 0.04 mm/D (18 studies; 95% confidence interval [CI], 0.03-0.06; I2 = 96.6%; P < 0.001). At the same time, LD, ACR, and PCR decreased by 0.06 mm/D (6 studies; 95%CI, -0.07-0.05; I2 = 50.1%; P < 0.001), 0.53 mm/D (8 studies; 95%CI, -0.64-0.41; I2 = 96.5%; P < 0.001), and 0.14 mm/D (9 studies; 95%CI, -0.19-0.09; I2 = 94.7%; P < 0.001) during accommodation, respectively. Moreover, LCP shifted forward by 0.01 mm/D (3 studies; 95%CI, -0.02-0.00; I2 = 0.0%; P < 0.001), and TCSA by 0.58 mm2/D (2 studies; 95%CI, 0.41-1.57; I2 = 97.0%; P = 0.457) during accommodation. Conclusions Changes in LT, LD, ACR, PCR and LCP supported Helmholtz's theory. Different apparatuses or measurement methods influenced the measurement of lens geometrical parameters.
Collapse
Affiliation(s)
- Guanghong Zhang
- Department of Ophthalmology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- School of Medicine, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- Sichuan Key Laboratory for Disease Gene Study, Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, No. 32 of the West 2nd Section of First Ring Road, Chengdu 610072, China
| | - Jun Jiang
- Department of Ophthalmology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- School of Medicine, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- Sichuan Key Laboratory for Disease Gene Study, Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, No. 32 of the West 2nd Section of First Ring Road, Chengdu 610072, China
| | - Qian Wei
- Southwest Medical University, No. 319, Section 3, Zhongshan Road, Luzhou 646000, China
| | - Chao Qu
- Department of Ophthalmology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- School of Medicine, University of Electronic Science and Technology of China, No. 2006, Xiyuan Ave West Hi-Tech Zone, Chengdu, CN 611731, China
- Sichuan Key Laboratory for Disease Gene Study, Chinese Academy of Sciences Sichuan Translational Medicine Research Hospital, No. 32 of the West 2nd Section of First Ring Road, Chengdu 610072, China
| |
Collapse
|
3
|
Lin F, Wang Y, Liu Y, Qu X, Zhou X. The Influence of 0.5% Tropicamide on Anterior Segment Parameters With CASIA2 in Emmetropic, Myopic, and Hyperopic Eyes. Front Physiol 2022; 13:957097. [PMID: 35903064 PMCID: PMC9315225 DOI: 10.3389/fphys.2022.957097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 06/23/2022] [Indexed: 11/25/2022] Open
Abstract
Aim: To evaluate the effects of 0.5% tropicamide on anterior segment parameters with the CASIA2 imaging device in emmetropic, myopic, and hyperopic eyes. Methods: In this prospective study, a total of 125 subjects (34 emmetropic subjects, 57 myopic subjects, and 34 hyperopic subjects) at the Shanghai Eye and ENT Hospital of Fudan University were recruited from June 2021 to September 2021. The 0.5% tropicamide solution was used once every 5 min a total of 5 times for cycloplegia. The anterior segment parameters were recorded by CASIA2 before and after cycloplegia. Changes in anterior segment parameters were compared among the three refractive groups. Results: Crystalline lens rise (CLR) and crystalline lens thickness (CLT) significantly decreased in all three refractive groups after cycloplegia (all p < 0.01). The anterior radius of lens (ARL) and anterior chamber depth (ACD) significantly increased in all three refractive groups after cycloplegia (all p < 0.01). Posterior radius of lens (PRL) significantly increased in hyperopic eyes after cycloplegia (p < 0.01) while it remained unchanged in emmetropic eyes and myopic eyes. Central corneal thickness (CCT), anterior chamber width (ACW), lens decentration (LD), and lens tilt (LT) remained unchanged after cycloplegia in all three refractive groups (all p > 0.05). Changes in CLR, CLT, ARL, PRL, and ACD in hyperopic eyes were greater than those in emmetropic eyes and myopic eyes (all p < 0.05). Conclusion: Apart from various changes in anterior segment parameters after application by 0.5% tropicamide in all three refractive groups, significant changes in CLR, CLT, ARL, PRL, and ACD in hyperopic eyes should be noted for proper clinical interpretation.
Collapse
Affiliation(s)
- Feng Lin
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Yuliang Wang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Yujia Liu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Xiaomei Qu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| |
Collapse
|
4
|
Mahmoud MSED, AbdelHalim AS, Zein HA. Effect of Light Conditions and Accommodation on Implantable Phakic Contact Lens Vault by Anterior Segment Optical Coherence Tomography. Clin Ophthalmol 2022; 16:1439-1447. [PMID: 35547401 PMCID: PMC9084507 DOI: 10.2147/opth.s359296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Accepted: 04/11/2022] [Indexed: 11/26/2022] Open
Abstract
Purpose To investigate the dynamic pupil and vault changes in eyes with implantable phakic contact lens (IPCL) under photopic and scotopic settings, as well as during accommodation using the anterior segment optical coherence tomography (AS-OCT). Methods A prospective observational study included consecutive 36 eyes of myopic patients who underwent IPCL V2.0 implantation. Under photopic and scotopic light settings, as well as during accommodation, all patients were scanned using CASIA OCT (CASIA2; TOMEY, Nagoya, Japan). The pupil size, the vault (distance between the back surface of the IPCL and the anterior lens capsule), ACD-lens (distance between the posterior corneal surface and the anterior lens surface), IPCL-lens (distance between the posterior corneal surface and the anterior IPCL surface), and lens thickness (LT) were the study parameters. Results The vault was significantly lower under photopic conditions (p-value<0.001). The pupil size was significantly smaller in photopic conditions (p-value<0.001). LT (p-value=0.975) and ACD-lens (p-value=0.917) were not significantly different between scotopic and photopic conditions, while the ACD-IPCL was significantly larger during photopic conditions (p-value=0.013). There were significant changes in all parameters between accommodative and non-accommodative conditions. Conclusion The IPCL vault decreased significantly under photopic light conditions and accommodation.
Collapse
Affiliation(s)
- Mohamed Salah El-Din Mahmoud
- Ophthalmology Department, Faculty of Medicine, Minia University, Minia, Egypt
- Correspondence: Mohamed Salah El-Din Mahmoud, Ophthalmology Department, Faculty of Medicine, Minia University, Minia, Egypt, Tel +20 1003321802, Email ;
| | | | - Hosny Ahmed Zein
- Ophthalmology Department, Faculty of Medicine, Minia University, Minia, Egypt
| |
Collapse
|
5
|
Mitsukawa T, Suzuki Y, Momota Y, Suzuki S, Yamada M. Effects of 0.01% Atropine Instillation Assessed Using Swept-Source Anterior Segment Optical Coherence Tomography. J Clin Med 2021; 10:jcm10194384. [PMID: 34640402 PMCID: PMC8509630 DOI: 10.3390/jcm10194384] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 01/16/2023] Open
Abstract
In this paper, we assessed the short-term effects of 0.01% atropine eye drops on anterior segment parameters by performing ocular biometry using a swept-source anterior segment optical coherence tomography system (AS-OCT). We recruited 17 healthy volunteers (10 men and 7 women aged 24–35 years) with no history of eye disease. Participants without accommodative demand demonstrated significant mydriasis 1 h after the atropine instillation (4.58 ± 0.77 to 5.41 ± 0.83 mm). Pupil diameters with a 5 diopter (D) accommodative stimulus at 1 h (4.70 ± 1.13 mm) and 24 h (4.05 ± 1.06 mm) after atropine instillation were significantly larger than those at baseline (3.71 ± 0.84 mm). Barring pupil diameter, no other biometric parameters significantly changed at any point in time after atropine instillation without accommodative demand. However, with an accommodative stimulus, anterior chamber depth (ACD) at 1 h and posterior curvature of the lens at 1 and 24 h were both significantly larger than those before atropine instillation. Using AS-OCT, we detected a slight decrease in the accommodation response of ocular biometric components evoked by 0.01% atropine instillation. Morphologically, our measurements suggested a change in the ACD and horizontal radius of the lens’ posterior surface curvatures due to the subtle reduction of accommodation.
Collapse
Affiliation(s)
| | - Yumi Suzuki
- Correspondence: ; Tel.: +81-422-47-5511; Fax: +81-422-46-9309
| | | | | | | |
Collapse
|
6
|
Dai C, Liu M, Lv X, Li B. Subtle changes of the crystalline lens after cycloplegia: a retrospective study. BMC Ophthalmol 2021; 21:124. [PMID: 33676428 PMCID: PMC7937324 DOI: 10.1186/s12886-021-01884-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Accepted: 02/25/2021] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND The purpose of this study was to evaluate the shape of the crystalline lens in terms of biometry and diopters before and after cycloplegia using the CASIA2 swept-source (SS) optical coherence tomography (OCT) system on the anterior segment. METHODS This was a retrospective study. Children and adolescents (26 males and 29 females, aged 4-21 years) with simple ametropia were selected for optometry and CASIA2 imaging at 2 separate visits before and after cycloplegia. Diopter values were derived from the spherical power (S) obtained by optometry. Biometric parameters of the crystalline lens, including the anterior chamber depth (ACD), anterior and posterior curvature of the lens (ACL and PCL), lens thickness (LTH), lens decentration (LD), lens tilt (LT), and equivalent diameter of the lens (LED), were measured by the CASIA2 system. The differences in these parameters after compared with before cycloplegia were determined, and their relationships were analyzed. RESULTS Fifty-five participants (106 eyes) were initially enrolled. There was a significant difference (P < 0.05) in the S (t=-7.026, P < 0.001), ACD (t=-8.796, P < 0.001), ACL (t=-13.263, P < 0.001) and LTH (t = 7.363, P < 0.001) after compared with before cycloplegia. The change in the PCL (t = 1.557, P = 0.122), LD (t = 0.876, P = 0.383), LT (t = 0.440, P = 0.661) and LED (t=-0.351, P = 0.726) was not statistically significant (P > 0.05). There was a significant (P < 0.05) correlation of the change in the S with that in the ACL (r = 0.466, P < 0.001), LTH (r=-0.592, P < 0.001), and LED (r = 0.223, P = 0.021) but not the PCL (r = 0.19, P = 0.051), LD (r=-0.048, P = 0.0628) or LT (r=-0.022, P = 0.822). Furthermore, the change in the ACD was closely related to the change in crystalline morphology. However, in children and adolescents, we found that the change in crystalline morphology was unrelated to age. CONCLUSIONS Changes in lens morphology after compared with before cycloplegia are mainly related to the ACL and LTH, but there is no difference in the PCL, LD, LT, or LED. In the adolescent population, change in the S is related to change in the ACL, LED and LTH. However, age is unrelated to the shape and tendency of the crystalline lens. Further research is required to determine whether the same conclusion applies to different age groups and different refractive states (myopia, hyperopia, emmetropia) .
Collapse
Affiliation(s)
- Cheng Dai
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China.,Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Meng Liu
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Xiaodong Lv
- Department of Clinical Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China
| | - Binzhong Li
- School of Basic Medicine, North Sichuan Medical College, Sichuan Province, 637000, Nanchong, China.
| |
Collapse
|
7
|
Li X, Chang P, Li Z, Qian S, Zhu Z, Wang Q, Yun-E Z. Agreement between anterior segment parameters obtained by a new ultrasound biomicroscopy and a swept-source fourier-domain anterior segment optical coherence tomography. Expert Rev Med Devices 2020; 17:1333-1340. [PMID: 33196325 DOI: 10.1080/17434440.2020.1848541] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Purpose: To evaluate the agreement between anew UBM and an SS-OCT. Methods: The scans of the right eye of each volunteer were obtained using the two devices. Data were fitted and recorded including: central corneal thickness (CCT), aqueous depth (AQD) (the distance from endothelium to lens), angle-to-angle distance (ATA), lens thickness (LT), diameter of the lens in the horizontal direction (LDiaangle: distance between the sharp angles on both sides of the lens, LDiaarc: distance between the vertex of the circular arcs on both sides of the lens), anterior and posterior corneal radius (Rf and Rb). Results: 25 eyes were included in this study. It could be seen that the differences in CCT, LDiaangle, Rf measured by the two instruments were not statistically significant. Bland-Altman analysis plots of CCT, LDiaangle and Rf showed mean differences of 0.2 µm, 0.01mm and 0.0mm for the 2 devices, respectively. Conclusion: The values of CCT, LDiaangle and Rf obtained via two instruments were not clinically interchangeable and the AQD, ATA, LT, and Rb have poor agreement affected by accommodation. We can estimate the real lens diameter by subtracting 0.61 ± 0.43mm when the lens diameter can only be simulated with SS-OCT.
Collapse
Affiliation(s)
- Xiuyuan Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Pingjun Chang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zhangliang Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Shuyi Qian
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zehui Zhu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Qianwei Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| | - Zhao Yun-E
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University , Wenzhou, Zhejiang, China.,National Clinical Research Center for Ocular Diseases , Wenzhou, Zhejiang, China
| |
Collapse
|