1
|
Insua Pereira E, Paula Sampaio A, Lira M. Tear levels of Transforming Growth Factor-β1 and Interleukin 1-β, and clinical correlations in new contact lens users. Cont Lens Anterior Eye 2024:102299. [PMID: 39232893 DOI: 10.1016/j.clae.2024.102299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2024] [Revised: 08/28/2024] [Accepted: 09/01/2024] [Indexed: 09/06/2024]
Abstract
PURPOSE To assess alterations in the tear Transforming Growth Factor (TGF)-β1 and Interleukin (IL1)-β concentration in new contact lens wearers; and explore correlations with tear film stability, and ocular physiological response. METHODS In this clinical setting, 12 neophytes (5 males), with an average age of 24.0 ± 5.0 years were fitted with delefilcon A contact lenses. Physiological responses (bulbar and limbal hyperemia), Pre-corneal (NIBUT), Pre-lens (PL-NIBUT) non-Invasive Break-Up Times, and tear samples were collected in the morning (before lens insertion; 9 - 10 a.m.) and afternoon (before lens removal; 7 - 8p.m.) of the same day. NIBUT and PL-NIBUT were measured using a tearscope. Tear samples were assayed for TGF-β1 and IL1-β concentrations using Enzyme-Linked Immunosorbent Assay kits. An 11-members control group (6 males) aged 25.0 ± 5.0, served to assess biomarker levels in non-contact lens wearers' tears. RESULTS Subjects wore lenses for an average of 7 h and 20 min (range: 6 to 9 h). Bulbar and limbal hyperemia increased significantly throughout the day (p < 0.001). PL-NIBUT were lower than NIBUT (4.7 ± 2.0 Vs. 12.2 ± 8.8 s; p < 0.001). The IL1-β levels were higher in neophytes than controls (3.2 ± 4.7 Vs. 0.1 ± 0.1 pg/ml; p = 0.05), correlating significantly with bulbar (r = 0.405, p = 0.008) and limbal hyperemia (r = 0.499, p = 0.027). No substantial changes were reported for TGF-β1. CONCLUSION The presence of TGF-β1 in tears does not appear significantly affected by lens wear. The association between physiological parameters and IL1-β levels suggests that lenses may disrupt ocular surface homeostasis by altering cytokine regulatory mechanisms. However, due to its low concentration, IL1-β's role in the subclinical inflammatory response to lens wear is limited.
Collapse
Affiliation(s)
| | - Ana Paula Sampaio
- Centre of Molecular and Environmental Biology (CBMA), University of Minho, Portugal
| | - Madalena Lira
- Centre of Physics (CF-UM-UP), School of Sciences, University of Minho, Portugal
| |
Collapse
|
2
|
Itokawa T, Okajima Y, Iwashita H, Koji K, Tashiro S, Suzuki T, Hori Y. Association between dryness sensation and ocular surface temperature and conjunctival blood flow in soft contact lens wearers. Cont Lens Anterior Eye 2024; 47:102166. [PMID: 38604915 DOI: 10.1016/j.clae.2024.102166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 04/02/2024] [Accepted: 04/04/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE To investigate the association between dryness, ocular surface temperature (OST), and conjunctival blood flow (CBF) in soft contact lens (SCL) wearers after airflow stimulation. METHODS After recruiting 21 SCL wearers (mean age, 25.3 ± 4.2 years), subjects used two different daily disposable silicone hydrogel SCLs (narafilcon A and delefilcon A lenses). On three of four measurement days, excluding the first, OST, CBF, tear meniscus height (TMH), and non-invasive tear break-up time (NIBUT) were measured after airflow stimulation at a rate of 3 m/s for 10 min. The measurements were conducted without SCLs on the first and second days, and with different SCLs on the third and fourth days. Dryness was evaluated using the visual analogue scale (VAS). These parameters were compared between the two types of SCLs, and their association with the dryness sensation was then investigated. RESULTS Dryness was significantly weakly correlated with OST (r = -0.375, p < 0.05) and CBF (r = 0.339, p < 0.05). TMH, NIBUT, and VAS scores for dryness with the delefilcon A lens (0.15 ± 0.05 mm, 3.7 ± 01.7 s and 29.4 ± 16.9) were significantly higher, longer, and lower, respectively, than those with the narafilcon A lens (0.12 ± 0.05 mm, 2.3 ± 1.7 s and 35.9 ± 17.0; p < 0.05, p < 0.01 and p < 0.01). The changes in the OST and CBF between with and without the delefilcon A lens (-0.36 ± 0.35 °C and 0.99 ± 0.19) were significantly small compared to the narafilcon A lens (-0.60 ± 0.42 °C and 1.11 ± 0.21; p < 0.01 for both comparisons). CONCLUSION Dryness was correlated with OST and CBF, which indicates that when dryness was high, OST was low and CBF was high. These results suggest that OST and CBF assessments are effective for evaluating dryness sensation.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan.
| | - Yukinobu Okajima
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Tsunashima Eye Clinic, Yokohama, Kanagawa, Japan
| | - Hiroko Iwashita
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Kakisu Koji
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Shigeki Tashiro
- Clinical Research Center, Nagasaki University Hospital, Nagasaki, Japan
| | - Takashi Suzuki
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Ishizuchi Eye Clinic, Niihama, Ehime, Japan
| | - Yuichi Hori
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
3
|
Phan CM, Wy Chan V, Drolle E, Hui A, Ngo W, Bose S, Shows A, Liang S, Sharma V, Subbaraman L, Zheng Y, Shi X, Wu J, Jones L. Evaluating the in vitro wettability and coefficient of friction of a novel and contemporary reusable silicone hydrogel contact lens materials using an in vitro blink model. Cont Lens Anterior Eye 2024; 47:102129. [PMID: 38423868 DOI: 10.1016/j.clae.2024.102129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 02/09/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
PURPOSE To evaluate the in vitro wettability and coefficient of friction of a novel amphiphilic polymeric surfactant (APS), poly(oxyethylene)-co-poly(oxybutylene) (PEO-PBO) releasing silicone hydrogel (SiHy) contact lens material (serafilcon A), compared to other reusable SiHy lens materials. METHODS The release of fluorescently-labelled nitrobenzoxadiazole (NBD)-PEO-PBO was evaluated from serafilcon A over 7 days in a vial. The wettability and coefficient of friction of serafilcon A and three contemporary SiHy contact lens materials (senofilcon A; samfilcon A; comfilcon A) were evaluated using an in vitro blink model over their recommended wearing period; t = 0, 1, 7, 14 days for all lens types and t = 30 days for samfilcon A and comfilcon A (n = 4). Sessile drop contact angles were determined and in vitro non-invasive keratographic break-up time (NIKBUT) measurements were assessed on a blink model via the OCULUS Keratograph 5 M. The coefficient of friction was measured using a nano tribometer. RESULTS The relative fluorescence of NBD-PEO-PBO decreased in serafilcon A by approximately 18 % after 7 days. The amount of NBD-PEO-PBO released on day 7 was 50 % less than the amount released on day 1 (6.5±1.0 vs 3.4±0.5 µg/lens). The reduction in PEO-PBO in the lens also coincided with an increase in contact angles for serafilcon A after 7 days (p < 0.05), although there were no changes in NIKBUT or coefficient of friction (p > 0.05). The other contact lens materials had stable contact angles and NIKBUT over their recommended wearing period (p > 0.05), with the exception of samfilcon A, which had an increase in contact angle after 14 days as compared to t = 0 (p < 0.05). Senofilcon A and samfilcon A also showed an increase in coefficient of friction at 14 and 30 days, respectively, compared to their blister pack values (p < 0.05). CONCLUSION The results indicate that serafilcon A gradually depletes its reserve of PEO-PBO over 1 week, but this decrease did not significantly change the lens performance in vitro during this time frame.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China.
| | - Vivian Wy Chan
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Elizabeth Drolle
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| | - Susmita Bose
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Amanda Shows
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Shuang Liang
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Vinay Sharma
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | | | - Ying Zheng
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Xinfeng Shi
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - James Wu
- Alcon Research LLC, Fort Worth TX & Johns Creek, GA, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong, China
| |
Collapse
|
4
|
Itokawa T, Yamasaki K, Suzuki T, Koh S. Advances in Contact Lens Care Solutions: PVP-I Disinfectant and HAD Wetting Agents From Japan. Eye Contact Lens 2024; 50:91-101. [PMID: 38019569 DOI: 10.1097/icl.0000000000001060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2023] [Indexed: 11/30/2023]
Abstract
ABSTRACT Half of the individuals who wear contact lenses use reusable lenses that require proper care. Improper contact lens (CL) care and using inadequate disinfecting solutions can lead to lens contamination, CL-related microbial keratitis, and Acanthamoeba keratitis. Oxidative disinfecting solutions, such as hydrogen peroxide, show higher efficacy than multipurpose solutions. Povidone-iodine (PVP-I), an oxidative disinfectant used in ophthalmic surgery, has been proven to be safe and effective. The PVP-I system, a CL disinfecting solution developed in Japan, has demonstrated excellent antimicrobial and antiviral properties. Although CL discomfort does not have a risk of ocular disorders with poor visual prognosis, such as keratitis, CL discomfort can still lead to lens dropout and thus needs to be addressed. To mitigate CL discomfort, it is essential to use disinfecting solutions containing surfactants and wetting agents that improve wettability of the lens surface. A CL solution containing hyaluronic acid derivatives (HADs) as wetting agents that permanently adhere to the lens surface to improve wettability of the lens surface was developed in Japan. There is potential for HAD to be integrated into various solutions. This article reviews the efficacy of novel PVP-I-based disinfecting solution and HAD wetting agents.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology (T.I., T.S.), Toho University, Tokyo, Japan; OPHTECS Corporation (K.Y.), Kobe Research Center, Kobe, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; Department of Innovative Visual Science (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan; and Department of Ophthalmology (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan
| | | | | | | |
Collapse
|
5
|
Itokawa T, Suzuki T, Koh S, Hori Y. Evaluating the Differences Between Fluorescein Tear Break-up Time and Noninvasive Measurement Techniques. Eye Contact Lens 2023; 49:104-109. [PMID: 36548980 DOI: 10.1097/icl.0000000000000966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/31/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To compare fluorescein tear break-up time (BUT) and noninvasive BUT measured using interferometry and corneal topography. METHODS We investigated 34 eyes of 34 patients with dry eye (mean age 39.2±8.3 years) and 16 eyes of 16 non-dry eye subjects (33.5±6.5 years). Tear film stability was measured using fluorescein BUT, noninvasive BUT (NIBUT)-DR1 with an interferometer, and noninvasive keratographic BUT (NIKBUT)-first and average using corneal topography. Correlations between fluorescein BUT and noninvasive BUT parameters were determined statistically. The noninvasive BUTs were compared between the dry eye and non-dry eye groups. The agreement between fluorescein and noninvasive BUTs was described using Bland-Altman analysis. RESULTS Fluorescein BUT was significantly correlated with NIBUT-DR1, NIKBUT-first, and NIKBUT-average. The Bland-Altman analysis revealed bias and 95% limits of agreement between fluorescein BUT and noninvasive BUTs as follows: NIBUT-DR1: 2.07 s, -5.33 to 9.46 s; NIKBUT-first: 3.39 s, -5.46 to 12.24 s; NIKBUT-average: 6.61 s, -1.58 to 14.79 s. The noninvasive BUTs were significantly different between the two groups. When NIBUT-DR1, NIKBUT-first, and NIKBUT-average with Bland-Altman correction were used as an index for dry eye, the cut-off values were 7.1, 8.4, and 11.6 s, respectively. The sensitivities were 0.735, 0.818, and 0.727 and specificities were 0.500, 0.437, and 0.562, respectively. CONCLUSION Fluorescein BUT and noninvasive BUTs were significantly correlated, and noninvasive BUTs had higher values than fluorescein BUT. Considering the differences between fluorescein BUT and noninvasive BUTs, noninvasive methods can be used as effective tool for diagnosing dry eye.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology (T.I., T.S., Y.H.), Toho University, Tokyo, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; and Department of Ophthalmology (S.K.), Osaka University, Osaka, Japan
| | | | | | | |
Collapse
|
6
|
Barrientos RT, Godín F, Rocha-De-Lossada C, Soifer M, Sánchez-González JM, Moreno-Toral E, González AL, Zein M, Larco P, Mercado C, Piedrahita MA. Ophthalmological Approach for the Diagnosis of Dry Eye Disease in Patients with Sjögren's Syndrome. Life (Basel) 2022; 12:1899. [PMID: 36431034 PMCID: PMC9692499 DOI: 10.3390/life12111899] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/13/2022] [Accepted: 11/14/2022] [Indexed: 11/17/2022] Open
Abstract
Dry eye has two basic subdivisions: aqueous deficient dry eye (ADDE), with SS a major cause; and evaporative dry eye (EDE), due to either intrinsic or extrinsic factors. SS is a chronic inflammatory disorder defined by dysfunction of the exocrine glands leading to dry eye and dry mouth. The objective of this article was to carry out a systematic and critical review of several scientific publications on dry eye disease, with the aim of providing general recommendations to distinguish dry eye and its different variants in patients with SS, during the period 1979 to 2020, using search engines for articles indexed in Scopus, Latindex, Scielo, Clinical Trials, Medline, Embase, and Cochrane, allowing the analysis of 132 articles published in indexed journals on the subject of dry eye disease and SS, evidencing its conceptualization, prevalence, risk factors, etiopathogenesis, clinical manifestations, diagnosis, and treatment.
Collapse
Affiliation(s)
| | - Fernando Godín
- Department of Ophthalmology, Research and Ocular Health Group, Unbosque, University of El Bosque, Bogota 110111, Colombia
| | - Carlos Rocha-De-Lossada
- Department of Ophthalmology, Qvision, VITHAS Almería Hospital, 04120 Almeria, Spain
- Department of Ophthalmology, Regional Universitary Hospital of Málaga, 18014 Granada, Spain
- Department of Surgery, Ophthalmology Area, University of Seville, 41012 Seville, Spain
- Department of Opthalmology, Vithas Malaga, 29016 Malaga, Spain
| | - Matias Soifer
- Department of Ophthalmology, National Eye Institute, National Institute of Health, Bethesda, MD 20892, USA
| | | | - Esteban Moreno-Toral
- Department of Pharmacy and Pharmaceutical Technology, University of Seville, 41012 Seville, Spain
| | - Ana-Luisa González
- Department of Ophthalmology, Research Department Clínica La Luz, Lima 15046, Peru
| | - Mike Zein
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | - Pablo Larco
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | - Carolina Mercado
- Department of Ophthalmology, Bascom Palmer Eye Institute, School of Medicine, University of Miami Miller, Miami, FL 33136, USA
| | | |
Collapse
|
7
|
Capote-Puente R, Bautista-Llamas MJ, Manzoni C, Sánchez-González JM. Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens. Life (Basel) 2022; 12:life12111710. [PMID: 36362865 PMCID: PMC9697334 DOI: 10.3390/life12111710] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/16/2022] [Accepted: 10/24/2022] [Indexed: 11/16/2022] Open
Abstract
To evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens wearers. A tear film analysis was achieved with the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA) from SBM System. The subjects were reassessed, with the contact lens, after 30 min of wearing to quantify the volume, stability and lipid pattern of the short-term pre-lens tear film. Lipid layer thickness decreased from 2.05 ± 1.53 to 1.90 ± 1.73 Guillon patterns (p = 0.23). First pre-lens NIBUT decreased from 5.03 ± 1.04 to 4.63 ± 0.89 s (p = 0.01). Mean pre-lens NIBUT significantly increased from 15.19 ± 9.54 to 21.27 ± 11.97 s (p < 0.01). Lid opening time significantly increased from 26.36 ± 19.72 to 38.58 ± 21.78 s (p < 0.01). The silicone hydrogel contact lens with water gradient technology significantly increased the mean pre-lens NIBUT and lid opening time. Lehfilcon A suggested an improvement in contact lens wearers with tear film instability or decreased subjective symptoms of dry eye disease.
Collapse
Affiliation(s)
- Raúl Capote-Puente
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
| | - María-José Bautista-Llamas
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
| | - Caterina Manzoni
- Department of Materials Science, Optics and Optometry Area, University of Milano-Bicocca, 20122 Milan, Italy
| | - José-María Sánchez-González
- Vision Research Group (CIVIUS), Department of Physics of Condensed Matter, Optica Area, University of Seville, 41012 Seville, Spain
- Correspondence:
| |
Collapse
|
8
|
Muhafiz E, Demir MS. Ability of non-invasive tear break-up time to determine tear instability in contact lens wearers. Int Ophthalmol 2021; 42:959-968. [PMID: 34677751 DOI: 10.1007/s10792-021-02079-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To evaluate the performance of precorneal and prelens non-invasive tear break-up time (NIBUT) measurements to determine tear instability in contact lens (CL) wearers. METHODS In this study, 50 eyes of 25 CL wearers were evaluated. Precorneal first and average NIBUTs and fluorescein tear break-up time (FBUT) were measured before wearing CLs in the morning. Those with FBUT less than 10 s were considered to have tear instability. After wearing CL, first and average prelens NIBUTs were measured at the 30th minute. The receiver operating characteristic (ROC) curve was analyzed to evaluate the performance of NIBUT measurements in the diagnosis of tear instability. RESULTS The FBUT value had a significant correlation with first and average precorneal NIBUT values (p < 0.001, r = 0.653 and p < 0.001, r = 0.628, respectively). The FBUT value had no correlation with the prelens first and average NIBUT values (p = 0.542 and p = 0.263, respectively). To understand the relationship between the precorneal and prelens NIBUT values measured by the automated method, their correlation was evaluated. There was no significant correlation between the precorneal and prelens NIBUTs (for all; p > 0.05). The area under curve (AUC) in ROC curve for the first and average precorneal NIBUTs were 0.842 (p < 0.001) and 0.810 (p < 0.001), respectively. The AUC values for the first and average prelens NIBUTs at the 30th minute of CL wear were 0.586 and 0.619, respectively (p = 0.317 and p = 0.166, respectively). CONCLUSIONS Precorneal NIBUT measurements may be useful in diagnosing tear instability. Prelens NIBUT values are not yet capable of adequately defining the tear film dynamics in CL wearers.
Collapse
Affiliation(s)
- Ersin Muhafiz
- Ophthalmology Department, Faculty of Medicine, Kafkas University, 36100, Merkez, Kars, Turkey.
| | - Mehmet Siraç Demir
- Ophthalmology Department, Van Training and Research Hospital, Van, Turkey
| |
Collapse
|
9
|
Fujimoto H, Ochi S, Yamashita T, Inoue Y, Kiryu J. Role of the Water Gradient Structure in Inhibiting Thin Aqueous Layer Break in Silicone Hydrogel-Soft Contact Lens. Transl Vis Sci Technol 2021; 10:5. [PMID: 34473222 PMCID: PMC8419878 DOI: 10.1167/tvst.10.11.5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Purpose Soft contact lenses (SCLs) are effective for refractive error correction, but prolonged wear triggers discomfort and discontinuation. This study investigates whether water gradient technology of delefilcon A-based SCLs improve tear film dynamics. Methods This retrospective observational study included 50 asymptomatic delefilcon A or narafilcon A users. Data on thin aqueous layer break (TALB; %), noninvasive tear break-up time (NIBUT), tear meniscus height (TMH; mm), subjective dryness, and higher-order aberrations (HOAs) were collected. Measurements of the bare eye, the SCL-worn eye after 15 minutes (visit 1 [v1]) and 30 ± 5 days after v1 after SCL was worn for ≥5 hours (visit 2 [v2]) were recorded. Results TALB was significantly reduced in the delefilcon A group compared to the narafilcon A group (33.3% vs. 85.5% at v1; P < 0.0001 and 31.7% vs. 80.4% at v2; P < 0.0001). The NIBUT was also significantly higher in the former (4.2 ± 2.1 seconds vs. 2.9 ± 1.5 at v1; P < 0.01 and 4.1 ± 2.3 seconds vs. 2.7 ± 1.6 seconds at v2; P < 0.01) across both visits. The TMH was significantly reduced in the former in both v1 and v2. The total ocular HOAs were significantly lower in the former at v1 (P < 0.001) and v2 (P < 0.05) compared to the bare eye. Conclusions The water gradient technology of delefilcon A reduces TALB and increases NIBUT. Translational Relevance The use of water gradient technology improves tear film dynamics and alleviate pathological break-up pattern, improving lens performance.
Collapse
Affiliation(s)
- Hisataka Fujimoto
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| | | | | | | | - Junichi Kiryu
- Department of Ophthalmology, Kawasaki Medical School, Kurashiki, Okayama, Japan
| |
Collapse
|
10
|
Carpena-Torres C, Pastrana C, Rodríguez-Pomar C, Serramito M, Carracedo G. Stabilization of comfort and visual quality after the insertion of soft contact lenses. Cont Lens Anterior Eye 2021; 45:101498. [PMID: 34373201 DOI: 10.1016/j.clae.2021.101498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 07/20/2021] [Accepted: 08/01/2021] [Indexed: 11/03/2022]
Abstract
PURPOSE To evaluate comfort, visual function, and in vivo wettability after the insertion of hydrogel and silicone hydrogel contact lenses for a better understanding of how long practitioners should wait for the initial evaluation of soft contact lenses. METHODS A short-term prospective, contralateral, randomized, and participant-masked study was carried out. Twenty healthy participants (25.4 ± 2.6 years) were evaluated after the insertion of two different soft contact lenses at different times (1, 5, 10, 20, 30 min). Ocufilcon D (hydrogel) and Somofilcon A (silicone hydrogel) contact lenses were randomly assigned to both eyes of the same participant. Comfort, visual function under photopic conditions in terms of high-contrast visual acuity, low-contrast visual acuity, contrast sensitivity, and in vivo wettability were measured. RESULTS There was an increase in comfort (p < 0.001), high-contrast visual acuity (p < 0.05), and contrast sensitivity (p < 0.001, only with silicone hydrogel) directly related to time after contact lens insertion. Besides, in vivo wettability suffered a statistically significant deterioration directly related to time with both contact lenses (p < 0.05). Except for comfort and contrast sensitivity, all the parameters stabilized their values 10 min after the insertion of both soft contact lenses. Additionally, in vivo wettability and visual acuity differences were found between hydrogel and silicone hydrogel contact lenses (p < 0.05). CONCLUSIONS It would be possible to properly evaluate high-contrast visual acuity, low-contrast visual acuity, and in vivo wettability 10 min after the insertion of both soft contact lenses.
Collapse
Affiliation(s)
- Carlos Carpena-Torres
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Cristina Pastrana
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Candela Rodríguez-Pomar
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - María Serramito
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| | - Gonzalo Carracedo
- Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
| |
Collapse
|