1
|
Hengerer FH, Auffarth GU, Conrad-Hengerer I. 7-Year Efficacy and Safety of iStent inject Trabecular Micro-Bypass in Combined and Standalone Usage. Adv Ther 2024; 41:1481-1495. [PMID: 38363465 PMCID: PMC10960914 DOI: 10.1007/s12325-024-02788-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 01/17/2024] [Indexed: 02/17/2024]
Abstract
INTRODUCTION This study evaluated 7-year effectiveness and safety of second-generation trabecular micro-bypass implantation (iStent inject) either in combination with cataract surgery or as a standalone procedure (Combined or Standalone subgroups, respectively) in eyes with open-angle glaucoma. METHODS This prospective, non-randomized, unmasked, longitudinal study included 125 consecutive iStent inject cases of a single surgeon at a large German academic hospital. Patients had considerable preoperative disease burden, with mean intraocular pressure (IOP) of 23.5 mmHg, 84.8% of eyes on ≥ 2 medications, and 38.4% of eyes with prior glaucoma surgery. IOP, medications, adverse events, and secondary surgeries were assessed through 7 years in the Overall cohort and in Combined (n = 81) and Standalone (n = 44) subgroups. RESULTS Over 7-year follow-up, mean IOP decreased by 36.2-40.0% in Overall eyes, 34.1-38.9% in Combined eyes, and 39.5-43.5% in Standalone eyes (p < 0.001 at all timepoints for all groups). Meanwhile, mean medications decreased by 59.3-71.3% in Overall eyes, 57.9-69.0% in Combined eyes, and 62.1-76.2% in Standalone eyes (p < 0.001 at all timepoints in all groups). At last follow-up (mean 77.4 months; 92.8% of patients with last visit at 6 or 7 years), 83.7% of Overall eyes, 82.3% of Combined eyes, and 86.4% of Standalone eyes had achieved ≥ 20% IOP reduction vs preoperative. At last follow-up vs preoperative, 100% of eyes in all groups had the same or lower IOP and 100% had the same or lower medication regimen. Safety outcomes were favorable, with no filtration surgeries and only 4.84% of eyes experiencing clinically significant visual field loss over 7 years of follow-up. CONCLUSION iStent inject implantation with or without phacoemulsification produced significant and durable 7-year reductions in IOP (~ 34-44% reduction) and medications (~ 58-76% reduction) while preventing filtering surgery in this cohort of patients with relatively high preoperative disease burden. Combined and Standalone cases had similarly favorable effectiveness and safety.
Collapse
Affiliation(s)
- Fritz H Hengerer
- David J Apple International Laboratory of Ophthalmic Pathology, Department of Ophthalmology, International Vision Correction Research Centre (IVCRC), Buergerhospital, University of Heidelberg, Frankfurt, Germany.
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Gerd U Auffarth
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ina Conrad-Hengerer
- University Eye Hospital, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Morita S, Sakanishi Y, Riyu I, Watanabe S, Ebihara N. Comparative evaluation of iStent versus iStent inject W combined with phacoemulsification in open angle glaucoma. PLoS One 2024; 19:e0297514. [PMID: 38315707 PMCID: PMC10843132 DOI: 10.1371/journal.pone.0297514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 12/29/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE The study aimed to compare the 12-month post-operative outcomes of iStent and iStent inject W (inject W), and the factors associated with their success in open-angle glaucoma. METHODS This single-center, retrospective comparative case series evaluated the medical records of patients who underwent iStent (comprising 1 stent) or inject W (comprising 2 stents) implantation with cataract surgery for primary open-angle glaucoma and normal tension glaucoma between January 2019 and March 2022. The 12-month post-operative efficacy outcomes included intraocular pressure (IOP), glaucoma medications, and survival analysis of the probability of success. "Failure" was defined as any of the following conditions compared to baseline: 1) IOP elevation, 2) increased glaucoma medication, or 3) IOP decline not exceeding 20% when glaucoma medication scores were comparable, and 4) need for additional glaucoma surgery. The safety outcomes included intra- and post-operative adverse events and changes in the best-corrected visual acuity and visual field. RESULTS The study comprised 55 eyes in the iStent and 105 in the inject W groups. At 12 months, treatment success was achieved in 66.0% of iStent and 78.4% of inject W eyes. The mean IOP was lower, and the percent reduction from baseline was equal in iStent-treated eyes (8.0% reduction, 14.8 mmHg to 13.7 mmHg, P<0.01) and inject W-treated eyes (11.9% reduction, 15.0 mmHg to 13.8 mmHg, P<0.01) (between-group comparison, P = 0.23). The mean medication burden decreased significantly from 2.5 to 1.1 for iStent (55.0% reduction, P<0.01) and 2.9 to 1.7 for iStent inject (46.8% reduction, P<0.01), with no significant differences between the two groups (P = 0.17). Both devices exhibited excellent safety. CONCLUSIONS Both devices significantly reduced IOP and glaucoma medication 12 months post-operatively. The outcome measures did not differ significantly between the two groups, and lower baseline IOP was predictive of surgical failure.
Collapse
Affiliation(s)
- Shuu Morita
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Yoshihito Sakanishi
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Ikari Riyu
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Satoshi Watanabe
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| | - Nobuyuki Ebihara
- Department of Ophthalmology, Juntendo University Urayasu Hospital, Tiba, Japan
| |
Collapse
|
3
|
Cantor L, Lindfield D, Ghinelli F, Świder AW, Torelli F, Steeds C, Dickerson Jr JE, Nguyen DQ. Systematic Literature Review of Clinical, Economic, and Humanistic Outcomes Following Minimally Invasive Glaucoma Surgery or Selective Laser Trabeculoplasty for the Treatment of Open-Angle Glaucoma with or Without Cataract Extraction. Clin Ophthalmol 2023; 17:85-101. [PMID: 36636619 PMCID: PMC9831079 DOI: 10.2147/opth.s389406] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 12/23/2022] [Indexed: 01/07/2023] Open
Abstract
Introduction Selective laser trabeculoplasty (SLT) and minimally invasive glaucoma surgery (MIGS) are increasingly used options for mild-to-moderate open-angle glaucoma (OAG) care. While most MIGS devices are indicated for use in combination with cataract surgery only, with phacoemulsification playing a role in lowering IOP, newer technologies can also be used as standalone glaucoma surgery. Methods This systematic literature review (SLR) aimed to assess the clinical, economic, and humanistic outcomes of MIGS and SLT for the treatment of OAG and was conducted according to PRISMA guidelines. Studies that assessed MIGS or SLT in at least one treatment arm versus any other glaucoma treatment in adults with mild-to-moderate OAG were included. Clinical, humanistic (health-related quality of life [HRQoL] and patient burden), and economic data were extracted, and the methodological quality of included studies was evaluated. Results A total of 2720 articles were screened, and 81 publications were included. Fifty-eight reported clinical outcomes. The majority assessed iStent or iStent inject (n=41), followed by OMNI (n=9), gonioscopy-assisted transluminal trabeculotomy (GATT) or the Kahook Dual Blade (KDB) (n=7), Hydrus (n=6), SLT (n=5), Xen Gel Stent (n=2), PreserFlo (n=1), and iTrack (n=1). IOP reduction was observed across prospective studies, varying from -31% to -13.7% at month 6 and from -39% to -11.4% at year 1 versus baseline. Most adverse events were transient and non-serious. Limited humanistic and economic data were identified. Conclusion Given their established efficacy and safety, there is a rationale for wider use of MIGS in mild-to-moderate OAG. Of the MIGS devices, iStent and OMNI have the largest clinical evidence base supporting their sustained effectiveness.
Collapse
Affiliation(s)
- Louis Cantor
- Eugene and Marilyn Glick Eye Institute, Indiana School of Medicine, Indianapolis, IN, USA
| | - Dan Lindfield
- Royal Surrey County Hospital, Guildford, England, UK
| | | | | | - Francesca Torelli
- Valid Insight, Macclesfield, England, UK,Correspondence: Francesca Torelli, Valid Insight, Ropewalks, Newton St, Macclesfield, SK11 6QJ, UK, Tel +44 203 750 9833 Ext 703, Email
| | | | - Jaime E Dickerson Jr
- Sight Sciences, Menlo Park, CA, USA,North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, USA
| | - Dan Q Nguyen
- Mid-Cheshire Hospitals NHS Foundation Trust, Crewe, UK
| |
Collapse
|
4
|
Clement C, Howes F, Ioannidis A, Shiu M, Manning D, Lusthaus JA, Skalicky SE, Goodwin TW. Multicenter Effectiveness and Disease Stability Through 3 Years After iStentTrabecular Micro-Bypass with Phacoemulsification in Glaucoma and Ocular Hypertension. Clin Ophthalmol 2022; 16:2955-2968. [PMID: 36071724 PMCID: PMC9444145 DOI: 10.2147/opth.s373290] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To evaluate 3-year safety and efficacy of two second-generation trabecular micro-bypass stents. (iStent inject®) with phacoemulsification. Materials and Methods This multicenter retrospective study of iStent inject implantation with phacoemulsification included data from eight surgeons across Australia. Eyes with cataract and mild to advanced glaucoma [predominantly primary open-angle (POAG), primary angle closure (PAC), or normal-tension (NTG) glaucoma] or ocular hypertension (OHT) were included. Study assessments included intraocular pressure (IOP); number of ocular hypotensive medications; proportions of eyes with 0, 1, 2, or ≥3 IOP-lowering medications; IOP ≤15 mmHg or ≤18 mmHg; visual fields (VF); retinal nerve fiber layer thickness (RNFL); central corneal thickness (CCT); intraoperative complications; adverse events; and secondary surgeries. Results A total of 273 eyes underwent surgery and had 36-month follow-up. At 36 months versus preoperative, mean IOP decreased by 15.5% (16.4±4.6 mmHg to 13.9±3.5 mmHg; p<0.001), and 70.3% of eyes achieved IOP of ≤15 mmHg (versus 49.1% preoperatively; p<0.001). The mean medication burden decreased by 68.5% (from 1.51±1.17 to 0.48±0.89 medications; p<0.001); 71.4% of eyes were medication-free (versus 21.6% preoperatively; p<0.001), while 6.2% of eyes were on ≥3 medications (versus 22.3% preoperatively; p<0.001); 96.3% of eyes maintained or reduced medications vs preoperative. Significant IOP and medication reductions occurred across glaucoma subtypes (POAG, PAC, NTG, OHT): 13–22% for IOP (p<0.05 for all) and 42–94% for medication (p<0.05 for all). Favorable safety included few adverse events; stable VF, RNFL, and CCT; and filtering surgery in only 8 eyes (2.9%) over 3 years. Conclusion In this multicenter cohort from 8 surgeons across Australia, significant IOP and medication reductions were sustained through 3 years after iStent inject implantation with phacoemulsification. Results were favorable across different glaucoma subtypes (including POAG, PAC, NTG, OHT), severities, and surgeons, thereby underscoring the real-world relevance and efficacy of iStent inject implantation for glaucoma treatment.
Collapse
Affiliation(s)
- Colin Clement
- Eye Associates, Sydney, NSW, Australia
- Fairfield Eye Surgery, Fairfield, NSW, Australia
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Correspondence: Colin Clement, Eye Associates, Level 4, 187 Macquarie Street, Sydney, NSW, 2000, Australia, Tel +612 9247 9972, Email
| | - Frank Howes
- Eye & Laser Centre, Gold Coast, QLD, Australia
| | | | | | - David Manning
- Hunter Cataract & Eye Centre, Charlestown, NSW, Australia
| | - Jed A Lusthaus
- Glaucoma Unit, Sydney Eye Hospital, Sydney, NSW, Australia
- Discipline of Ophthalmology, The University of Sydney, Sydney, NSW, Australia
- Eyehaus, Sydney, NSW, Australia
| | - Simon E Skalicky
- Department of Surgery Ophthalmology, University of Melbourne, Melbourne, VIC, Australia
| | | |
Collapse
|
5
|
iStent inject Trabecular Micro-Bypass with or Without Cataract Surgery Yields Sustained 5-Year Glaucoma Control. Adv Ther 2022; 39:1417-1431. [PMID: 35113323 PMCID: PMC8918186 DOI: 10.1007/s12325-021-02039-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 12/23/2021] [Indexed: 11/05/2022]
Abstract
Introduction This study evaluated the 5-year effectiveness and safety of iStent inject® trabecular micro-bypass with or without cataract surgery (Combined or Standalone, respectively) in patients with open-angle glaucoma (OAG). Methods This prospective longitudinal case series included consecutive iStent inject cases from a single surgeon at a large German academic hospital. Intraocular pressure (IOP), medications, safety, and indicators of disease stability through 5 years were assessed in the Overall cohort and in subgroup analyses stratified by usage (Combined or Standalone). Results Preoperative mean IOP in the Overall cohort (n = 125) was 23.5 ± 6.2 mmHg on 2.68 ± 1.02 mean medications, reducing to 14.1 ± 1.8 mmHg on 0.77 ± 0.82 medications at 5 years (40% and 71% reductions, respectively; both p < 0.001). All but 1 eye (> 99%) were on medication(s) preoperatively, but 46% were medication-free at 5 years (p < 0.001). In Combined eyes (n = 81), mean IOP decreased by 39% (22.6 mmHg to 13.8 mmHg, p < 0.001) and medications by 69% (2.52 to 0.78, p < 0.001). In Standalone eyes, mean IOP reduced by 42% (25.3 mmHg to 14.6 mmHg, p < 0.001) and medications by 75% (2.98 to 0.74, p < 0.001). At final follow-up, 83% of eyes had achieved ≥ 20% IOP reduction, and all but 1 eye (> 99%) had the same or lower IOP versus preoperative; all eyes (100%) maintained or reduced their medication burden versus preoperative. Favorable safety included 0 intraoperative complications and 0 filtration surgeries through 5 years. Long-term indicators of disease stability (visual fields, retinal nerve-fiber layer thickness, and cup:disc ratio) were unchanged over the course of 5-year follow-up. Conclusions iStent inject produced significant and durable 5-year reductions in IOP (nearly 10-mmHg reduction) and medications (nearly 2-medication reduction), with stable disease parameters over time. Combined and Standalone subgroups had similar outcomes.
Collapse
|
6
|
Rho S, Lim SH. Clinical Outcomes After Second-Generation Trabecular Microbypass Stents (iStent inject®) with Phacoemulsification in Korean Patients. Ophthalmol Ther 2021; 10:1105-1117. [PMID: 34699014 PMCID: PMC8589960 DOI: 10.1007/s40123-021-00412-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 10/07/2021] [Indexed: 11/26/2022] Open
Abstract
INTRODUCTION To evaluate the intraocular pressure (IOP)-lowering effect of second-generation trabecular microbypass stents (iStent® inject) with cataract extraction (combination group) and compare refractive changes in the combination group and the control (phacoemulsification only) group. METHODS This retrospective case-control study included 36 eyes with cataract and medically controlled open-angle glaucoma with IOP < 21 mmHg and 100 nonglaucomatous eyes with cataract. Data were collected preoperatively and for 6 months postoperatively. Data included IOP, number of glaucoma medications, corrected distance visual acuity, and mean absolute error (MAE) from target refraction, and astigmatic vector analysis. Surgical success for the combination group was defined according to three criteria: (A) IOP < 15 mmHg without medication, (B) IOP < 18 mmHg without medication, and (C) IOP < 18 mmHg with or without medication. RESULTS In the combination group, mean IOP was reduced from 15.1 ± 2.9 mmHg to 12.5 ± 2.0 mmHg, and the mean number of medications decreased from 1.9 ± 1.0 to 0.4 ± 0.8 at postoperative 6 months (both P < 0.001). Surgical success rates were 77.8%, 83.3%, and 97.2% at 6 months by criteria A, B, and C, respectively. Mean IOP was reduced from 14.3 ± 2.7 mmHg to 13.1 ± 2.1 mmHg at 1 month in the control group (P < 0.001). The MAE was 0.33 ± 0.26 D, and 83.3% of eyes had spherical equivalent difference within 0.50 D in the combination group (0.38 ± 0.33 D and 76.0% in the control group; P = 0.309 and P = 0.363, respectively). Preoperative and postoperative centroid values were 0.51 D @ 1° and 0.66 D @ 178°, respectively (0.23 D @ 176° and 0.66 D @ 1° in the control group). There were no statistical differences between the two groups with respect to preoperative and postoperative mean absolute values (P = 0.154 and P = 0.322, respectively). CONCLUSIONS On the basis of our results using Korean real-world interim experience, iStent® inject with cataract extraction has favorable IOP-lowering effects and minimally impacts refractive outcomes.
Collapse
Affiliation(s)
- Seungsoo Rho
- Department of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam, South Korea
| | - Su-Ho Lim
- Department of Ophthalmology, Daegu Veterans Health Service Medical Center, #60 Wolgok-Ro, Dalseo-Gu, Daegu, 42835, South Korea.
| |
Collapse
|